facility summary in gallatin county in the city of...

108
Facility Summary in GALLATIN County in the City of BELGRADE YELLOWSTONE JET CENTER LLC 490 GALLATIN FIELD RD Sys Fac ID: BELGRADE, MT 59714 GALLATIN 16-04440 Operating Permit Renewal Date: 8/4/2021 Last Inspected On: 4/24/2018 Location: Kent Foster, (406) 388-4152 Contact: Owners/Operators: Signature Flight Support, Owner 201 S ORANGE AVE STE 1100 ORLANDO FL 32801-3478 (407)-648-7200 Kent Foster, Operator 456 GALLATIN FIELD RD BELGRADE MT 59714-8544 (406)-388-3814 Michael Russell, UST Class A Operator Al Sandvold, UST Class A Operator Robert Lemon, UST Class B Operator Tom Melum, UST Class B Operator Dennis A Franks, UST Class B Global Operator Tank Id Status Product Capacity Installed Age Tank Material of Construction Piping Material Piping Type Secondary Option Secondary Option Tag Number AST Spill Protected Overfill Types CP Met Types ATG Type Tank Detection Primary Pipe Detection Secondary Pipe Detection Catastrophic L.D. Type 3.0 Vapor Recovery Energy Act Sump Tightness Inventory Control Tank/Pipe CP Line Tightness Currently in Use 1 Jet Fuel 12,000 Cathodically Protected Steel Steel Impressed Current None 4/11/1977 Safe Suction 41 2037 Yes High Level Alarm Impressed Current TLS-450 , Veeder Root Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2 Deferred Not Required 7/28/2016 Currently in Use 2 Jet Fuel 12,000 Cathodically Protected Steel Steel Lined Interior/Impressed Current None 4/11/1977 Safe Suction 41 2038 Yes High Level Alarm Impressed Current TLS-450 , Veeder Root Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2 Deferred Not Required 7/28/2016 Currently in Use 3 Jet Fuel 12,000 Cathodically Protected Steel Steel Lined Interior/Impressed Current None 4/12/1975 Safe Suction 43 2039 Yes High Level Alarm Impressed Current TLS-450 , Veeder Root Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2 Deferred Not Required 7/28/2016 Report Generation Date: 12/12/2018 Page 531

Upload: others

Post on 11-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

YELLOWSTONE JET CENTER LLC

490 GALLATIN FIELD RD

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-04440

Operating Permit Renewal Date: 8/4/2021

Last Inspected On: 4/24/2018

Location:

Kent Foster, (406) 388-4152Contact:

Owners/Operators: Signature Flight Support, Owner 201 S ORANGE AVE STE 1100ORLANDO FL 32801-3478

(407)-648-7200

Kent Foster, Operator 456 GALLATIN FIELD RDBELGRADE MT 59714-8544

(406)-388-3814

Michael Russell, UST Class A Operator

Al Sandvold, UST Class A Operator

Robert Lemon, UST Class B Operator

Tom Melum, UST Class B Operator

Dennis A Franks, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Jet Fuel

12,000

Cathodically Protected Steel Steel

Impressed Current None

4/11/1977

Safe Suction

41

2037 Yes

High Level Alarm

Impressed Current

TLS-450 , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Deferred

Not Required

7/28/2016

Currently in Use

2

Jet Fuel

12,000

Cathodically Protected Steel Steel

Lined Interior/Impressed Current None

4/11/1977

Safe Suction

41

2038 Yes

High Level Alarm

Impressed Current

TLS-450 , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Deferred

Not Required

7/28/2016

Currently in Use

3

Jet Fuel

12,000

Cathodically Protected Steel Steel

Lined Interior/Impressed Current None

4/12/1975

Safe Suction

43

2039 Yes

High Level Alarm

Impressed Current

TLS-450 , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Deferred

Not Required

7/28/2016

Report Generation Date: 12/12/2018 Page 531

Page 2: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

YELLOWSTONE JET CENTER LLC

490 GALLATIN FIELD RD

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-04440

Operating Permit Renewal Date: 8/4/2021

Last Inspected On: 4/24/2018

Location:

Kent Foster, (406) 388-4152Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Jet Fuel

12,000

Cathodically Protected Steel Steel

Lined Interior/Impressed Current None

4/12/1975

Pressurized

43

2040 Yes

High Level Alarm

Impressed Current

TLS-450 , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Deferred

Not Required

7/28/2016

Currently in Use

5

Jet Fuel

12,000

Cathodically Protected Steel Steel

Impressed Current None

4/12/1975

Safe Suction

43

2041 Yes

High Level Alarm

Impressed Current

TLS-450 , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Deferred

Not Required

7/28/2016

Currently in Use

6

Jet Fuel

12,000

Bare Steel Steel

Impressed Current None

4/12/1975

Safe Suction

43

2042 Yes

High Level Alarm

Impressed Current

TLS-450 , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Deferred

Not Required

7/28/2016

Currently in Use

7

Aviation Gas

12,000

Cathodically Protected Steel Steel

Impressed Current None

4/11/1977

Safe Suction

41

2036 Yes

High Level Alarm

Impressed Current

TLS-450 , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Deferred

Not Required

7/28/2016

Report Generation Date: 12/12/2018 Page 532

Page 3: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

FLYING J INC BELGRADE

6505 JACKRABBIT LN

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-05753

Operating Permit Renewal Date: 12/17/2020

Last Inspected On: 10/3/2017

Location:

Damon Borden, (509) 534-1502Contact:

Owners/Operators: A & H Investments LLC, Owner/Operator PO BOX 14646SPOKANE WA 99214

(509)-534-1502

Randell Goff, UST Class A Operator

Ryan Webster, UST Class A Operator

Frieda Holloway, UST Class B Operator

Randell Goff, UST Class B Global Operator

Ryan Webster, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

10,000

Bare Steel Fiberglass Reinforced Plastic

Impressed Current None

4/1/1976

Pressurized

42

3796 Yes

High Level Alarm, Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

9/28/2017

9/28/2017

Currently in Use

2

Gasoline

10,000

Bare Steel Fiberglass Reinforced Plastic

Impressed Current None

4/26/1976

Pressurized

42

3795 Yes

High Level Alarm, Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

9/28/2017

9/28/2017

Currently in Use

3

Diesel

28,000

Bare Steel Fiberglass Reinforced Plastic

Impressed Current Double-Walled

4/26/1976

Pressurized

42

3797 Yes

High Level Alarm

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

Continuous Interstitial Monitor, ELLD Line Tightness Testing

Electronic Line Leak Detector

9/28/2017

7/11/2017

Report Generation Date: 12/12/2018 Page 533

Page 4: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

FLYING J INC BELGRADE

6505 JACKRABBIT LN

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-05753

Operating Permit Renewal Date: 12/17/2020

Last Inspected On: 10/3/2017

Location:

Damon Borden, (509) 534-1502Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

28,000

Bare Steel Flexible Plastic

Impressed Current None

4/26/1976

Pressurized

42

3793 Yes

High Level Alarm

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

9/28/2017

9/28/2017

Currently in Use

5

Diesel

28,000

Bare Steel Flexible Plastic

Impressed Current Double-Walled

4/26/1976

Pressurized

42

3794 Yes

High Level Alarm

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

Continuous Interstitial Monitor, ELLD Line Tightness Testing

Electronic Line Leak Detector

9/28/2017

8/1/2017

Report Generation Date: 12/12/2018 Page 534

Page 5: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

TOWN PUMP INC BELGRADE 3

305 E MAIN ST

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-07788

Operating Permit Renewal Date: 5/31/2021

Last Inspected On: 2/2/2018

Location:

Trent Biggers, (406) 497-6700Contact:

Owners/Operators: Great Falls Holdings LLC, Owner/Operator PO BOX 6000BUTTE MT 59702-6000

(406)-497-6700

Don Edmisten, UST Class A Operator

Daniel Sampson, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Daniel Sampson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

7

Diesel

10,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

8/29/2005

Pressurized

13

5016 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Electronic Line Leak Detector

Yes9/11/2005

Currently in Use

8

Gasoline

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

8/29/2005

Pressurized

13

5017 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Electronic Line Leak Detector

Yes9/11/2005

Currently in Use

9

Gasoline

20,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

8/29/2005

Pressurized

13

5026 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Electronic Line Leak Detector

Yes9/11/2005

Report Generation Date: 12/12/2018 Page 535

Page 6: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

ROCKY MOUNTAIN SUPPLY INC BELGRADE

350 JACKRABBIT LN

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-12101

Operating Permit Renewal Date: 2/26/2021

Last Inspected On: 1/15/2018

Location:

(406) 388-4008Contact:

Owners/Operators: Rocky Mountain Supply Inc, Owner/Operator JASON RORABAUGH PETROLEUM MGR210 GALLATIN FARMERS AVEBELGRADE MT 59714-3947

(406)-388-4008

Jason Rorabaugh, UST Class A Operator

Elizabeth Flikkema, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

12,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

9/20/1990

Pressurized

28

1189 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Stat. Inventory Reconcilitation

Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

12/13/2014

10/31/2017

Currently in Use

2

Gasoline

20,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

9/20/1990

Pressurized

28

1190 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Stat. Inventory Reconcilitation

Automatic Tank Gauging 0.2

Electronic Line Leak Detector

12/13/2014

5/17/2011

Currently in Use

3

Diesel

12,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

9/20/1990

Pressurized

28

1191 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Stat. Inventory Reconcilitation

Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

12/13/2014

10/31/2017

Report Generation Date: 12/12/2018 Page 536

Page 7: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

ROCKY MOUNTAIN SUPPLY INC BELGRADE

350 JACKRABBIT LN

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-12101

Operating Permit Renewal Date: 2/26/2021

Last Inspected On: 1/15/2018

Location:

(406) 388-4008Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Diesel

20,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None Double-Walled

9/20/1990

Pressurized

28

1192 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Stat. Inventory Reconcilitation

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor, ELLD Line Tightness Testing

Electronic Line Leak Detector

12/13/2014

11/1/2017

Currently in Use

5

Diesel

8,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None Double-Walled

10/24/2003

Pressurized

15

4867 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Stat. Inventory Reconcilitation

Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

12/13/2014

11/1/2017

Under Construction

6

Gasoline

6,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

4/1/2019

Pressurized

99

5896 Yes

Positive Shutoff, High Level Alarm

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

Yes

Yes

Under Construction

7

Diesel

6,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

4/1/2019

Pressurized

99

5897 Yes

Positive Shutoff, High Level Alarm

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

Yes

Report Generation Date: 12/12/2018 Page 537

Page 8: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

ROCKY MOUNTAIN SUPPLY INC BELGRADE

350 JACKRABBIT LN

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-12101

Operating Permit Renewal Date: 2/26/2021

Last Inspected On: 1/15/2018

Location:

(406) 388-4008Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Under Construction

8

DEF (Not Regulated)

6,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

4/1/2019

Pressurized

99

5898 Yes

Positive Shutoff, High Level Alarm

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

Report Generation Date: 12/12/2018 Page 538

Page 9: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

GALLATIN FIELD CARDLOCK

GALLATIN FIELD

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-12952

Operating Permit Renewal Date: 7/22/2019

Last Inspected On: 6/15/2016

Location:

Jason Shanley, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Gary Scales, UST Class A Operator

Jason Shanley, UST Class A Operator

Jason Shanley, UST Class B Operator

Gary Scales, UST Class B Global Operator

Kelly Scott Shutes, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

4,000

Bare Steel Fiberglass Reinforced Plastic

None None

11/1/1992

Pressurized

26

Yes2032 Yes

Not Applicable

Deferred MLLD Line Tightness Testing

Mechanical Line Leak Detector

6/15/2016

Report Generation Date: 12/12/2018 Page 539

Page 10: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

TOWN PUMP INC BELGRADE

203 W JEFFERSON AVE

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-13625

Operating Permit Renewal Date: 10/27/2021

Last Inspected On: 8/22/2018

Location:

Kevin Kenneally, (406) 388-0129Contact:

Owners/Operators: Belgrade Town Pump Inc, Owner/Operator PO BOX 6000BUTTE MT 59701-6000

(406)-497-6700

Don Edmisten, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

5/1/1995

Pressurized

23

2454 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Mechanical Line Leak Detector

Yes

6/30/2015

Currently in Use

2

Gasoline

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

5/1/1995

Pressurized

23

2455 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Mechanical Line Leak Detector

Yes

6/30/2015

Currently in Use

3

Gasoline

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

5/1/1995

Safe Suction

23

2456 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Continuous Interstitial Monitoring

Yes

Currently in Use

4

Gasoline

12,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

5/1/1995

Pressurized

23

4371 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Mechanical Line Leak Detector

Yes

6/30/2015

Report Generation Date: 12/12/2018 Page 540

Page 11: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

TOWN PUMP INC BELGRADE

203 W JEFFERSON AVE

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

16-13625

Operating Permit Renewal Date: 10/27/2021

Last Inspected On: 8/22/2018

Location:

Kevin Kenneally, (406) 388-0129Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Gasoline

12,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

5/1/1995

Pressurized

23

2458 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Mechanical Line Leak Detector

6/30/2015

Report Generation Date: 12/12/2018 Page 541

Page 12: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

QWEST COMMUNICATIONS

95 N BROADWAY

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

56-13996

Operating Permit Renewal Date: 3/14/2021

Last Inspected On: 12/15/2017

Location:

Kevin Robison, (801) 237-3006Contact:

Owners/Operators: Qwest Corporation/Century Link, Owner 2250 E 200 S 10TH FLOORSALT LAKE CITY UT 84111

(801)-238-0337

Kevin Robison, Operator 250 BELL PLZ RM #1601SALT LAKE CITY UT 84111-2095

(801)-238-0337

Stephanie Miller, UST Class A Operator

Thomas J Pitts, UST Class A Operator

Kevin Robison, UST Class A Operator

Thomas J Pitts, UST Class B Operator

Stephanie Miller, UST Class B Global Operator

Thomas J Pitts, UST Class B Global Operator

Kevin Robison, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

1,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

11/1/2001

U.S. Suction

17

4266 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

MLLD Line Tightness Testing

Continuous Interstitial Monitor

Auto Dialer

12/1/2017

Report Generation Date: 12/12/2018 Page 542

Page 13: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

BELGRADE CARD LOCK

163 THUNDER RD

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

56-14162

Operating Permit Renewal Date: 3/16/2021

Last Inspected On: 11/29/2017

Location:

Calvin Wilson, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Jason Shanley, UST Class A Operator

Calvin Wilson, UST Class A Operator

Jason Shanley, UST Class B Global Operator

Kelly Scott Shutes, UST Class B Global Operator

Calvin Wilson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

12,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/5/2005

Pressurized

13

4999 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/29/2017

Currently in Use

2

Gasoline

20,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/5/2005

Pressurized

13

5000 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/5/2017

Currently in Use

3

Diesel

12,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/5/2005

Pressurized

13

5001 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/5/2017

Report Generation Date: 12/12/2018 Page 543

Page 14: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

BELGRADE CARD LOCK

163 THUNDER RD

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

56-14162

Operating Permit Renewal Date: 3/16/2021

Last Inspected On: 11/29/2017

Location:

Calvin Wilson, (406) 587-0702Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

8,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/5/2005

Pressurized

13

5002 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/1/2017

Currently in Use

5

Diesel

15,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/16/2005

Pressurized

13

5003 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/1/2017

Currently in Use

6

Diesel

6,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/5/2005

Pressurized

13

5004 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/1/2017

Currently in Use

7

Diesel

20,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/5/2005

Pressurized

13

5063 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/19/2017

Report Generation Date: 12/12/2018 Page 544

Page 15: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

TOWN PUMP INC BELGRADE 2

691 JACKRABBIT LN

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

60-15008

Operating Permit Renewal Date: 5/31/2021

Last Inspected On: 2/2/2018

Location:

(406) 388-7060Contact:

Owners/Operators: Great Falls Holdings LLC, Owner/Operator PO BOX 6000BUTTE MT 59702-6000

(406)-497-6700

Don Edmisten, UST Class A Operator

Daniel Sampson, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Daniel Sampson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

25,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

9/20/2005

Pressurized

13

5019 Yes

Positive Shutoff, Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

2

Diesel

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

9/20/2005

Pressurized

13

5020 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Currently in Use

3

Diesel

10,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

9/20/2005

Pressurized

13

5021 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Report Generation Date: 12/12/2018 Page 545

Page 16: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

TOWN PUMP INC BELGRADE 2

691 JACKRABBIT LN

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

60-15008

Operating Permit Renewal Date: 5/31/2021

Last Inspected On: 2/2/2018

Location:

(406) 388-7060Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

15,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

9/20/2005

Pressurized

13

5022 Yes

Positive Shutoff, Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Currently in Use

5

Diesel

15,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

9/20/2005

Pressurized

13

5023 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Report Generation Date: 12/12/2018 Page 546

Page 17: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

GALLATIN FIELD AIRPORT

633 GALLATIN FIELD RD

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

60-15152

Operating Permit Renewal Date: 7/3/2019

Last Inspected On: 6/1/2016

Location:

Gary Scales, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Gary Scales, UST Class A Operator

Jason Shanley, UST Class A Operator

Gary Scales, UST Class B Global Operator

Jason Shanley, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

12,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

4/13/2010

Not Listed

08

5236 Yes

Ball Float Valve

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

Yes

12/26/2012

5/13/2016

Report Generation Date: 12/12/2018 Page 547

Page 18: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

CENTRAL COPTERS

395 JETWAY DR

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

60-15232

Operating Permit Renewal Date: 8/24/2019

Last Inspected On: 8/5/2016

Location:

Mark Duffy, (406) 586-9185Contact:

Owners/Operators: Central Copters, Owner/Operator PO BOX 7300BOZEMAN MT 59771-7300

(406)-586-9185

Mark Duffy, UST Class A Operator

Brian Geary, UST Class A Operator

Mark Duffy, UST Class B Operator

Brian Geary, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Jet Fuel

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

3/1/2016

Pressurized

02

5547 Yes

Positive Shutoff, High Level Alarm

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Continuous Interstitial Monitor

Not Listed

Auto Dialer

Yes

10/21/2015

Report Generation Date: 12/12/2018 Page 548

Page 19: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

TOWN PUMP INC BELGRADE 4

561 BUSINESS HUB DR

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

60-15245

Operating Permit Renewal Date: 1/22/2021

Last Inspected On: 10/9/2017

Location:

Charlie Armstrong, (406) 497-6700Contact:

Owners/Operators: Town and Country Supply and Management, Owner/Operator PO BOX 6000BUTTE MT 59702-6000

(406)-497-6700

Charles A Armstrong, UST Class A Operator

Don Edmisten, UST Class A Operator

Charles A Armstrong, UST Class B Global Operator

Don Edmisten, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

30,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5484 Yes

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

6/3/2014

Currently in Use

2

Diesel

30,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5485 Yes

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

6/3/2014

Currently in Use

3

Diesel

30,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5486 Yes

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

6/3/2014

Report Generation Date: 12/12/2018 Page 549

Page 20: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BELGRADE

TOWN PUMP INC BELGRADE 4

561 BUSINESS HUB DR

Sys Fac ID:

BELGRADE, MT 59714 GALLATIN

60-15245

Operating Permit Renewal Date: 1/22/2021

Last Inspected On: 10/9/2017

Location:

Charlie Armstrong, (406) 497-6700Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

30,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5487 Yes

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

6/3/2014

Currently in Use

5

Gasoline

20,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5488 No

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

6/3/2014

Currently in Use

6

Diesel

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5489 No

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

6/3/2014

Currently in Use

7

Diesel

20,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5490 No

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Groundwater Monitoring, Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

6/3/2014

Other

8

DEF (Not Regulated)

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/14/2014

Pressurized

04

5491 No

Positive Shutoff

Not Applicable

Continuous Interstitial Monitor Continuous Interstitial Monitor

Not Listed Yes

Report Generation Date: 12/12/2018 Page 550

Page 21: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BIG SKY

BIG SKY CONOCO

91 LONE MOUNTAIN TRL

Sys Fac ID:

BIG SKY, MT 59716 GALLATIN

16-03801

Operating Permit Renewal Date: 10/24/2019

Last Inspected On: 7/5/2016

Location:

Renae Schumacher, (406) 995-4275Contact:

Owners/Operators: Nevermore Inc, Owner/Operator PO BOX 160640BIG SKY MT 59716-0640

(406)-995-4275

Renae Schumacher, UST Class A Operator

Steve Schumacher, UST Class A Operator

Dennis A Franks, UST Class B Operator

Steve Schumacher, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Gasoline

12,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

5/1/1997

Pressurized

21

3155 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

7/5/2016

Currently in Use

7

Gasoline

12,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

5/1/1997

Pressurized

21

3156 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

7/5/2016

Temporarily Out of Use

8

Diesel

1,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

5/1/1997

U.S. Suction

21

3157 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Continuous Interstitial Monitor

Not Required

9/10/2013

Report Generation Date: 12/12/2018 Page 551

Page 22: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BIG SKY

BIG SKY CONOCO

91 LONE MOUNTAIN TRL

Sys Fac ID:

BIG SKY, MT 59716 GALLATIN

16-03801

Operating Permit Renewal Date: 10/24/2019

Last Inspected On: 7/5/2016

Location:

Renae Schumacher, (406) 995-4275Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

9

Diesel

2,500

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

6/1/2001

Pressurized

17

4488 Yes

Positive Shutoff

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

7/5/2016

Report Generation Date: 12/12/2018 Page 552

Page 23: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BIG SKY

TOM GERRARD

2300 N FORK RD

Sys Fac ID:

BIG SKY, MT 59716 GALLATIN

16-13672

Operating Permit Renewal Date: 12/6/2019

Last Inspected On: 10/12/2016

Location:

Scott Hammond, (406) 995-9100Contact:

Owners/Operators: William Tom Gerrard, Owner/Operator PO BOX 160777BIG SKY MT 59716-0777

(406)-995-9100

Jay Reader, UST Class A Operator

Dennis A Franks, UST Class B Global Operator

Jay Reader, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

1,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

9/1/1995

U.S. Suction

23

3936 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Continuous Interstitial Monitor

Auto Dialer

10/12/2016

Currently in Use

2

Gasoline

1,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

10/1/1998

Safe Suction

20

3726 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Continuous Interstitial Monitor, Deferred

Not Required

Report Generation Date: 12/12/2018 Page 553

Page 24: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BIG SKY

WATERMARK HOME

341 ANDESITE RIDGE RD

Sys Fac ID:

BIG SKY, MT 59716 GALLATIN

60-15032

Operating Permit Renewal Date: 1/11/2020

Last Inspected On: 9/28/2016

Location:

Bill Rode, (406) 209-1400Contact:

Owners/Operators: Watermark Services, Owner/Operator BILL RODEPO BOX 161864BIG SKY MT 59716-1864

(406)-209-1400

Edd Gryder, UST Class A Operator

Edd Gryder, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

3,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

10/24/2006

U.S. Suction

12

5133 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Continuous Interstitial Monitor

Auto Dialer

9/28/2016

Report Generation Date: 12/12/2018 Page 554

Page 25: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

COLLEGE EXXON SERVICE STATION

723 S 8TH AVE

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-00472

Operating Permit Renewal Date: 8/20/2021

Last Inspected On: 8/17/2018

Location:

Harold Sappington, (406) 587-4453Contact:

Owners/Operators: College Chevron of Bozeman Inc, Owner/Operator 723 S 8TH AVEBOZEMAN MT 59715-4414

(406)-587-4453

David Lapinski, UST Class A Operator

David Lapinski, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Gasoline

6,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/1/1998

Pressurized

20

694 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Continuous Interstitial Monitor

Continuous Interstitial Monitoring

8/16/2018

8/17/2018

Currently in Use

7

Gasoline

4,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/1/1998

Pressurized

20

695 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Continuous Interstitial Monitor

Continuous Interstitial Monitoring

8/16/2018

8/17/2018

Report Generation Date: 12/12/2018 Page 555

Page 26: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

WILLIAMS PUMP & PAK INC

2020 N 7TH AVE

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-00758

Operating Permit Renewal Date: 11/6/2020

Last Inspected On: 8/21/2017

Location:

Alan Williams, (406) 587-0485Contact:

Owners/Operators: Williams Pump & Pak Inc, Owner/Operator 2020 N 7TH AVEBOZEMAN MT 59715-2516

(406)-587-0485

Alan Williams, UST Class A Operator

Alan Williams, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

6/1/1997

Pressurized

21

2275 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

8/3/2017

Currently in Use

5

Gasoline

12,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

6/1/1997

Pressurized

21

2276 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

8/3/2017

Report Generation Date: 12/12/2018 Page 556

Page 27: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

GRANTREE CONOCO

1417 N 7TH AVE

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-01254

Operating Permit Renewal Date: 12/24/2019

Last Inspected On: 11/1/2016

Location:

Jacob Marks, (406) 587-0651Contact:

Owners/Operators: Grantree Conoco, Owner/Operator 1417 N 7TH AVEBOZEMAN MT 59715-2513

(406)-587-5261

Missy Tallman, UST Class A Operator

Missy Tallman, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Gasoline

12,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/1/1995

Pressurized

23

3299 Yes

Auto Limiter

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

4/5/2016

4/14/2016

Currently in Use

6

Gasoline

12,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/1/1995

Pressurized

23

3300 Yes

Auto Limiter

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

4/5/2016

4/14/2016

Currently in Use

7

Diesel

8,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/1/1995

Pressurized

23

3301 Yes

Auto Limiter

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

4/5/2016

4/14/2016

Currently in Use

8

Diesel

4,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

9/1/1995

Pressurized

23

3302 Yes

Auto Limiter

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

4/5/2016

4/14/2016

Report Generation Date: 12/12/2018 Page 557

Page 28: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

BRIDGER BOWL INC

15795 BRIDGER CANYON RD

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-01793

Operating Permit Renewal Date: 10/1/2021

Last Inspected On: 6/4/2018

Location:

Robert Allen, (406) 587-2111Contact:

Owners/Operators: Bridger Bowl Inc, Owner/Operator 15795 BRIDGER CANYON RDBOZEMAN MT 59715-8282

(406)-587-2111

Robert Allen, UST Class A Operator

Daniel Doehring, UST Class A Operator

Daniel Doehring, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Diesel

100

Cathodically Protected Steel Flexible Plastic

None Double-Walled

11/1/1995

U.S. Suction

23

491 Yes

Galvanic

Deferred Deferred

Not Required

8/11/2015

Currently in Use

8

Diesel

2,000

Cathodically Protected Steel Flexible Plastic

Double-Walled Double-Walled

10/30/1998

Safe Suction

20

492 Yes

Flapper Valve (Auto Shutoff)

Galvanic

Manual Interstitial Monitor Continuous Interstitial Monitor

Not Required

8/11/2015

Currently in Use

9

Gasoline

1,000

Cathodically Protected Steel Flexible Plastic

Double-Walled Double-Walled

10/30/1998

Safe Suction

20

493 Yes

Flapper Valve (Auto Shutoff)

Galvanic

Manual Interstitial Monitor Continuous Interstitial Monitor

Not Required

8/11/2015

Report Generation Date: 12/12/2018 Page 558

Page 29: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

PHILLIPS 66 BOZEMAN TERMINAL

318 W GRIFFIN DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-01844

Operating Permit Renewal Date: 10/31/2020

Last Inspected On: 6/13/2017

Location:

Joshua Brown, (406) 255-2504Contact:

Owners/Operators: Phillips 66 Pipeline LLC, Owner 2626 LILLIAN AVEBILLINGS MT 59101

(406)-255-5714

Phillips 66 Bozeman Terminal, Operator 318 W GRIFFIN DRBOZEMAN MT 59715

(406)-587-7060

Joshua B Brown, UST Class A Operator

Chase Keith, UST Class A Operator

Joshua B Brown, UST Class B Operator

Chase Keith, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

12

Gasoline

840,000

Unknown Steel - Terminal Piping

None None

1/1/1955

Pressurized

63

Yes715 Yes

Not Applicable, Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

5/4/2017

6/6/2017

Currently in Use

14

Gasoline

840,000

Unknown Steel - Terminal Piping

None None

1/1/1955

Pressurized

63

Yes717 Yes

Not Applicable, Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

5/4/2017

6/6/2017

Temporarily Out of Use

17

Mixture

1,680,000

Unknown Steel - Terminal Piping

None None

1/1/1966

Pressurized

52

Yes722 Yes

Not Applicable, Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

5/23/2014

5/13/2011

Report Generation Date: 12/12/2018 Page 559

Page 30: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

PHILLIPS 66 BOZEMAN TERMINAL

318 W GRIFFIN DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-01844

Operating Permit Renewal Date: 10/31/2020

Last Inspected On: 6/13/2017

Location:

Joshua Brown, (406) 255-2504Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

18

Diesel

840,000

Unknown Steel - Terminal Piping

None None

1/1/1955

Pressurized

63

Yes716 Yes

Not Applicable, Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

5/4/2017

6/6/2017

Currently in Use

20

Diesel

840,000

Unknown Steel - Terminal Piping

None None

1/1/1955

Pressurized

63

Yes720 Yes

Not Applicable, Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

5/4/2017

6/8/2017

Currently in Use

23

Mixture

1,500

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

1/1/2000

Gravity Feed

18

4698 Yes

High Level Alarm

Not Applicable

Other , Other

Continuous Interstitial Monitor Deferred

Not Required

6/24/2014

5/4/2017

6/13/2017

Report Generation Date: 12/12/2018 Page 560

Page 31: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

THRIFTWAY SUPER STOP 10

919 W COLLEGE ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-03432

Operating Permit Renewal Date: 6/12/2019

Last Inspected On: 5/30/2016

Location:

Louis Sutey, (406) 494-2305Contact:

Owners/Operators: Sutey Oil Co Inc, Owner/Operator 2000 HOLMES AVEBUTTE MT 59701-3553

(406)-494-2305

Bryan Kelsey, UST Class A Operator

Louis Sutey, UST Class A Operator

Ryan Foreman, UST Class B Operator

Dan Franti, UST Class B Operator

Bryan Kelsey, UST Class B Operator

Dave Stine, UST Class B Operator

Louis Sutey, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Bare Steel Steel

Impressed Current None

7/1/1983

Pressurized

35

812 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/1/2016

4/10/2018

Currently in Use

2

Gasoline

10,000

Bare Steel Steel

Impressed Current None

7/1/1983

Pressurized

35

4434 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/1/2016

4/10/2018

Currently in Use

3

Gasoline

10,000

Bare Steel Steel

Impressed Current None

7/1/1983

Pressurized

35

814 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/1/2016

4/10/2018

Report Generation Date: 12/12/2018 Page 561

Page 32: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

THRIFTWAY SUPER STOP 11

621 W MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-03800

Operating Permit Renewal Date: 6/12/2019

Last Inspected On: 5/31/2016

Location:

Louis Sutey, (406) 494-2305Contact:

Owners/Operators: Sutey Oil Co Inc, Owner/Operator 2000 HOLMES AVEBUTTE MT 59701-3553

(406)-494-2305

Bryan Kelsey, UST Class A Operator

Louis Sutey, UST Class A Operator

Bryan Kelsey, UST Class B Operator

Dave Stine, UST Class B Operator

Louis Sutey, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

5/1/1990

Pressurized

28

815 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/19/2016

4/19/2016

Currently in Use

7

Gasoline

8,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

5/1/1990

Pressurized

28

816 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/19/2016

4/19/2016

Currently in Use

8

Diesel

8,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

5/1/1990

Pressurized

28

817 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/19/2016

4/19/2016

Report Generation Date: 12/12/2018 Page 562

Page 33: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

LOAF 'N JUG #729

1910 W MAIN ST

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-03913

Operating Permit Renewal Date: 6/14/2019

Last Inspected On: 5/17/2016

Location:

Shirley Treece, (719) 948-5976Contact:

Owners/Operators: Mini Mart Inc dba Loaf 'N Jug, Owner/Operator 442 KEELER PKWYPUEBLO CO 81001-4813

(719)-948-3071

Randal Liebnow, UST Class A Operator

John Sumowski, UST Class A Operator

Scott Huether, UST Class B Operator

Timothy Osterman, UST Class B Operator

Stevie Ulstad, UST Class B Operator

Jennifer Coleman, UST Class B Global Operator

Randal Liebnow, UST Class B Global Operator

Toni Mullen, UST Class B Global Operator

Hiede Richardson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

11/1/1985

Pressurized

33

1642 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/7/2018

3/18/2014

Currently in Use

2

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

11/1/1985

Pressurized

33

1639 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/7/2018

3/18/2014

Report Generation Date: 12/12/2018 Page 563

Page 34: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

LOAF 'N JUG #729

1910 W MAIN ST

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-03913

Operating Permit Renewal Date: 6/14/2019

Last Inspected On: 5/17/2016

Location:

Shirley Treece, (719) 948-5976Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

3

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

11/1/1985

Pressurized

33

1640 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/7/2018

3/18/2014

Currently in Use

4

Diesel

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

11/1/1985

Pressurized

33

1641 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/7/2018

3/18/2014

Report Generation Date: 12/12/2018 Page 564

Page 35: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

THRIFTWAY SUPER STOP 8

8192 HUFFINE LN

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-05064

Operating Permit Renewal Date: 11/13/2019

Last Inspected On: 5/30/2016

Location:

Louis Sutey, (406) 494-2305Contact:

Owners/Operators: Sutey Oil Co Inc, Owner/Operator 2000 HOLMES AVEBUTTE MT 59701-3553

(406)-494-2305

Bryan Kelsey, UST Class A Operator

Louis Sutey, UST Class A Operator

Michael Beck, UST Class B Operator

Viki Clayton, UST Class B Operator

Bryan Kelsey, UST Class B Operator

Deza Rae Pitt, UST Class B Operator

Dave Stine, UST Class B Operator

Louis Sutey, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Gasoline

15,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

8/1/1998

Pressurized

20

2053 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

Currently in Use

6

Gasoline

15,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

8/1/1998

Pressurized

20

2054 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

Currently in Use

7

Diesel

6,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

8/1/1998

Pressurized

20

2055 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

Report Generation Date: 12/12/2018 Page 565

Page 36: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

SAFEWAY FUEL 2999

1801 W MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-05474

Operating Permit Renewal Date:

Last Inspected On:

Location:

Jesse Wees, (208) 412-7561Contact:

Owners/Operators: Albertsons, Owner/Operator DEPT 72405PO BOX 20BOISE ID 83726-0020

(208)-421-7561

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Under Construction

5

Gasoline

20,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

10/1/2018

Pressurized

00

5870 No

Not Listed Not Listed

Not Listed

Under Construction

6

Gasoline

8,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

10/1/2018

Pressurized

00

5871 No

Not Listed Not Listed

Not Listed

Under Construction

7

Diesel

15,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

10/1/2018

Pressurized

00

5872 No

Not Listed Not Listed

Not Listed

Under Construction

8

Gasoline

8,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

10/1/2018

Pressurized

00

5873 No

Not Listed Not Listed

Not Listed

Report Generation Date: 12/12/2018 Page 566

Page 37: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

LOAF 'N JUG #728

717 W COLLEGE ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-05778

Operating Permit Renewal Date: 9/13/2019

Last Inspected On: 5/17/2016

Location:

Shirley Treece, (719) 948-5976Contact:

Owners/Operators: Mini Mart Inc dba Loaf 'N Jug, Owner/Operator 442 KEELER PKWYPUEBLO CO 81001-4813

(719)-948-3071

Randal Liebnow, UST Class A Operator

John Sumowski, UST Class A Operator

David Cordova, UST Class B Operator

Timothy Osterman, UST Class B Operator

Stevie Ulstad, UST Class B Operator

Jennifer Coleman, UST Class B Global Operator

Randal Liebnow, UST Class B Global Operator

Toni Mullen, UST Class B Global Operator

Hiede Richardson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

6,000

Bare Steel Flexible Plastic

Impressed Current Double-Walled

4/25/1981

Pressurized

37

3641 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/11/2014

5/22/2015

12/18/2014

Currently in Use

2

Gasoline

4,000

Bare Steel Flexible Plastic

Impressed Current Double-Walled

4/25/1981

Pressurized

37

3642 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/11/2014

5/22/2015

12/18/2014

Report Generation Date: 12/12/2018 Page 567

Page 38: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

LOAF 'N JUG #728

717 W COLLEGE ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-05778

Operating Permit Renewal Date: 9/13/2019

Last Inspected On: 5/17/2016

Location:

Shirley Treece, (719) 948-5976Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

3

Gasoline

6,000

Bare Steel Flexible Plastic

Impressed Current Double-Walled

4/25/1981

Pressurized

37

3643 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

12/11/2014

5/22/2015

12/18/2014

Report Generation Date: 12/12/2018 Page 568

Page 39: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

ZIP TRIP 46

1210 E MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-06596

Operating Permit Renewal Date: 5/26/2019

Last Inspected On: 1/7/2016

Location:

Harry Huntsinger, (406) 633-2359Contact:

Owners/Operators: CHS Inc Spokane Valley, Owner 16124 E MARIETTA LNSPOKANE WA 99213

(509)-535-7701

Cenex Zip Trip, Operator 16124 E MARIETTA LNSPOKANE VALLEY WA 99216

(509)-535-7701

Jim Alford, UST Class A Operator

Ian Johnstone, UST Class A Operator

Nicholas Merritt, UST Class A Operator

Nicholas Merritt, UST Class B Operator

Darcy Ziegler, UST Class B Operator

Jim Alford, UST Class B Global Operator

Ian Johnstone, UST Class B Global Operator

Nicholas Merritt, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Bare Steel Fiberglass Reinforced Plastic

Impressed Current None

4/3/1985

Pressurized

33

2105 Yes

Flapper Valve (Auto Shutoff)

Impressed Current, Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

4/17/2013

Currently in Use

2

Gasoline

10,000

Bare Steel Fiberglass Reinforced Plastic

Impressed Current None

4/3/1985

Pressurized

33

2106 Yes

Flapper Valve (Auto Shutoff)

Impressed Current, Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

4/17/2013

Report Generation Date: 12/12/2018 Page 569

Page 40: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

ZIP TRIP 46

1210 E MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-06596

Operating Permit Renewal Date: 5/26/2019

Last Inspected On: 1/7/2016

Location:

Harry Huntsinger, (406) 633-2359Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

3

Diesel

8,000

Bare Steel Fiberglass Reinforced Plastic

Impressed Current None

4/3/1985

Pressurized

33

2107 Yes

Flapper Valve (Auto Shutoff)

Impressed Current, Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

4/17/2013

Report Generation Date: 12/12/2018 Page 570

Page 41: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

CASEYS CORNER #1

81855 GALLATIN RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-06922

Operating Permit Renewal Date: 7/22/2019

Last Inspected On: 6/20/2016

Location:

Calvin Wilson, (406) 600-0619Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Calvin Wilson, UST Class A Operator

Angelina Matthews, UST Class B Operator

Brandis Moe, UST Class B Operator

Samantha Riffe, UST Class B Operator

Nancy Kennedy, UST Class B Global Operator

Kelly Scott Shutes, UST Class B Global Operator

Calvin Wilson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

12,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

5/1/1996

Pressurized

22

2024 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector5/1/2006

5/2/2016

11/9/2016

Currently in Use

5

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/10/1991

Pressurized

27

2018 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

9/13/2017

5/2/2016

Currently in Use

6

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/10/1991

Pressurized

27

2019 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

9/13/2017

5/2/2016

Report Generation Date: 12/12/2018 Page 571

Page 42: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

CASEYS CORNER #1

81855 GALLATIN RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-06922

Operating Permit Renewal Date: 7/22/2019

Last Inspected On: 6/20/2016

Location:

Calvin Wilson, (406) 600-0619Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

7

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/10/1991

Pressurized

27

2020 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

9/13/2017

5/2/2016

Currently in Use

8

Diesel

2,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

5/1/1996

Pressurized

22

2021 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

9/13/2017

5/1/2006

5/2/2016

Currently in Use

9

Diesel

6,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

5/1/1996

Pressurized

22

2022 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

9/13/2017

5/1/2006

5/2/2016

Currently in Use

10

Diesel

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

5/1/1996

Pressurized

22

2023 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

9/13/2017

5/1/2006

5/2/2016

Report Generation Date: 12/12/2018 Page 572

Page 43: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

CASEYS CORNER #1

81855 GALLATIN RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-06922

Operating Permit Renewal Date: 7/22/2019

Last Inspected On: 6/20/2016

Location:

Calvin Wilson, (406) 600-0619Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Other

11

DEF (Not Regulated)

4,000

Fiberglass Reinforced Plastic Other

Double-Walled Double-Walled

9/17/2017

Pressurized

01

5769 No

Positive Shutoff

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Continuous Interstitial Monitor

Not Listed

Not Required

9/13/2017

Report Generation Date: 12/12/2018 Page 573

Page 44: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

STRAIGHTAWAY MOTORS

5 E MENDENHALL ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-07197

Operating Permit Renewal Date: 5/4/2021

Last Inspected On: 2/15/2018

Location:

Peter H Colvin, (406) 586-2569Contact:

Owners/Operators: Straightaway Motors, Owner/Operator 5 E MENDENHALL STBOZEMAN MT 59715-3666

(406)-586-2569

Eric Colvin, UST Class A Operator

Peter H Colvin, UST Class A Operator

Peter H Colvin, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Waste Oil

2,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

Double-Walled None

7/1/1992

Gravity Feed

26

1387 Yes

Galvanic

Manual Interstitial Monitor MLLD Line Tightness Testing

Not Required

2/15/2018

2/15/2018

Report Generation Date: 12/12/2018 Page 574

Page 45: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

CASEYS #2

1211 E MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08188

Operating Permit Renewal Date: 12/31/2019

Last Inspected On: 10/25/2016

Location:

Calvin Wison, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Calvin Wilson, UST Class A Operator

Pam Diamond, UST Class B Operator

Thomas Dickson, UST Class B Operator

Randall Greene, UST Class B Operator

Jessika Hensley, UST Class B Operator

Elizabeth Hickman, UST Class B Operator

Edye Macrow, UST Class B Operator

Kelly Scott Shutes, UST Class B Global Operator

Calvin Wilson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/1/1998

Pressurized

20

4576 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/17/2018

10/25/2016

Currently in Use

5

Diesel

4,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/1/1998

Pressurized

20

4577 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/17/2018

10/25/2016

Report Generation Date: 12/12/2018 Page 575

Page 46: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

CASEYS #2

1211 E MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08188

Operating Permit Renewal Date: 12/31/2019

Last Inspected On: 10/25/2016

Location:

Calvin Wison, (406) 587-0702Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Diesel

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/1/1998

Pressurized

20

2030 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/17/2018

10/25/2016

Currently in Use

7

Gasoline

12,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

4/1/1998

Pressurized

20

2031 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

5/17/2018

10/25/2016

Report Generation Date: 12/12/2018 Page 576

Page 47: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

CASEYS CORNER #3

1420 N 7TH AVE

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08190

Operating Permit Renewal Date: 12/31/2019

Last Inspected On: 10/25/2016

Location:

Jason Shanley, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Calvin Wilson, UST Class A Operator

Ryan Allen, UST Class B Operator

Tanner De Long, UST Class B Operator

Randall Greene, UST Class B Operator

Ladonna Lambert, UST Class B Operator

Ginny Strobel, UST Class B Operator

Kelly Scott Shutes, UST Class B Global Operator

Calvin Wilson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

12/1/1998

Pressurized

20

3687 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1

Continuous Interstitial Monitor

Electronic Line Leak Detector

10/25/2016

7/26/2016

Currently in Use

7

Gasoline

14,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

12/1/1998

Pressurized

20

3688 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1

Continuous Interstitial Monitor

Electronic Line Leak Detector

10/25/2016

10/16/2016

Currently in Use

8

Diesel

8,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

12/28/2005

Pressurized

12

5054 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1

Continuous Interstitial Monitor

Electronic Line Leak Detector

10/7/2010

10/15/2016

Report Generation Date: 12/12/2018 Page 577

Page 48: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

BOZEMAN KARDLOCK

300 E GRIFFIN DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08191

Operating Permit Renewal Date: 1/15/2020

Last Inspected On: 11/28/2016

Location:

Gary Scales, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Gary Scales, UST Class A Operator

Jason Shanley, UST Class A Operator

Gary Scales, UST Class B Global Operator

Jason Shanley, UST Class B Global Operator

Kelly Scott Shutes, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

12,000

Cathodically Protected Steel Flexible Plastic

Lined Interior/Impressed Current Double-Walled

5/2/1978

Pressurized

40

3864 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/28/2016

Currently in Use

2

Gasoline

8,000

Cathodically Protected Steel Flexible Plastic

Lined Interior/Impressed Current Double-Walled

5/2/1978

Pressurized

40

3865 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/28/2016

Currently in Use

3

Diesel

8,000

Cathodically Protected Steel Flexible Plastic

Lined Interior/Impressed Current Double-Walled

5/2/1978

Pressurized

40

3866 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/28/2016

11/16/2010

Report Generation Date: 12/12/2018 Page 578

Page 49: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

BOZEMAN KARDLOCK

300 E GRIFFIN DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08191

Operating Permit Renewal Date: 1/15/2020

Last Inspected On: 11/28/2016

Location:

Gary Scales, (406) 587-0702Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Diesel

10,000

Cathodically Protected Steel Flexible Plastic

Impressed Current Double-Walled

1/1/1986

Pressurized

32

3867 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/28/2016

Currently in Use

5

Diesel

10,000

Cathodically Protected Steel Flexible Plastic

Impressed Current Double-Walled

1/1/1986

Pressurized

32

3868 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/28/2016

Report Generation Date: 12/12/2018 Page 579

Page 50: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

TOWN PUMP INC BOZEMAN 1

803 E MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08674

Operating Permit Renewal Date: 8/25/2021

Last Inspected On: 3/28/2018

Location:

Don Edmisten, (406) 497-6700Contact:

Owners/Operators: Sky View Holdings LLC, Owner/Operator PO BOX 6000BUTTE MT 59701

(406)-497-6700

Don Edmisten, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

9

Gasoline

20,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/1/2015

Pressurized

03

5520 Yes

Flapper Valve (Auto Shutoff), Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

3/3/2015

Currently in Use

10

Gasoline

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/1/2015

Pressurized

03

5521 Yes

Flapper Valve (Auto Shutoff), Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

3/3/2015

Currently in Use

11

Diesel

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/1/2015

Pressurized

03

5522 Yes

Flapper Valve (Auto Shutoff), Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

3/3/2015

Report Generation Date: 12/12/2018 Page 580

Page 51: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

TOWN PUMP INC BOZEMAN 1

803 E MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08674

Operating Permit Renewal Date: 8/25/2021

Last Inspected On: 3/28/2018

Location:

Don Edmisten, (406) 497-6700Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

12

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/1/2015

Pressurized

03

5523 Yes

Flapper Valve (Auto Shutoff), Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

3/3/2015

Currently in Use

13

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

4/1/2015

Pressurized

03

5524 Yes

Flapper Valve (Auto Shutoff), Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

3/3/2015

Report Generation Date: 12/12/2018 Page 581

Page 52: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

TOWN PUMP INC BOZEMAN 2

2607 W MAIN ST

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-08675

Operating Permit Renewal Date: 5/31/2021

Last Inspected On: 2/2/2018

Location:

Trent Biggers, (406) 497-6700Contact:

Owners/Operators: Bozeman Town Pump Inc, Owner/Operator PO BOX 6000BUTTE MT 59702-6000

(406)-497-6700

Don Edmisten, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/11/1984

Pressurized

34

2441 Yes

Ball Float Valve

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Electronic Line Leak Detector

2/1/2018

Currently in Use

2

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/11/1984

Pressurized

34

2442 Yes

Ball Float Valve

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Electronic Line Leak Detector

2/1/2018

Currently in Use

3

Diesel

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None none

4/11/1984

Pressurized

34

2443 Yes

Ball Float Valve

Impressed Current

TLS-350/Gilbarco EMC , Veeder Root

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Electronic Line Leak Detector

2/1/2018

Currently in Use

4

Gasoline

12,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

4/1/1989

Pressurized

29

2444 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Electronic Line Leak Detector

2/1/2018

Report Generation Date: 12/12/2018 Page 582

Page 53: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

EXXONMOBIL BOZEMAN PRODUCTS TERMINAL

220 W GRIFFIN DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08730

Operating Permit Renewal Date: 5/27/2019

Last Inspected On: 2/23/2016

Location:

Chris Martin, (406) 586-6927Contact:

Owners/Operators: Exxon Mobil Corporation, Owner/Operator 220 W GRIFFIN DRBOZEMAN MT 59715

(832)-625-7781

Michael P Bailey, UST Class A Operator

Michael James, UST Class A Operator

Bry Joaillier Allen, UST Class A Operator

Janie Lee, UST Class A Operator

Christopher Scott Martin, UST Class A Operator

Robert Ochsenbein, UST Class A Operator

James Vokral Sup, UST Class A Operator

Christopher Scott Martin, UST Class B Operator

Michael P Bailey, UST Class B Global Operator

Michael James, UST Class B Global Operator

Bry Joaillier Allen, UST Class B Global Operator

Janie Lee, UST Class B Global Operator

Robert Ochsenbein, UST Class B Global Operator

James Vokral Sup, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

2

Other

420,000

Bare Steel Steel

None None

6/1/1954

Pressurized

64

Yes2815 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Currently in Use

4

Gasoline

2,000

Fiberglass Reinforced Plastic Steel

Double-Walled None

6/1/1988

Gravity Feed

30

3702 Yes

High Level Alarm

Not Applicable, Impressed Current

Other , Other

Continuous Interstitial Monitor MLLD Line Tightness Testing

Not Required6/1/1998

12/5/2015

10/6/2015

Report Generation Date: 12/12/2018 Page 583

Page 54: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

EXXONMOBIL BOZEMAN PRODUCTS TERMINAL

220 W GRIFFIN DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08730

Operating Permit Renewal Date: 5/27/2019

Last Inspected On: 2/23/2016

Location:

Chris Martin, (406) 586-6927Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

7

Diesel

420,000

Bare Steel Steel - Terminal Piping

None None

6/1/1954

Pressurized

64

Yes2813 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Currently in Use

10

Diesel

630,000

Bare Steel Steel - Terminal Piping

None None

6/1/1954

Pressurized

64

Yes2811 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Currently in Use

12

Gasoline

420,000

Bare Steel Steel - Terminal Piping

None None

6/1/1954

Pressurized

64

Yes2809 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Currently in Use

13

Gasoline

1,260,000

Bare Steel Steel - Terminal Piping

None None

6/1/1954

Pressurized

64

Yes4851 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Currently in Use

15

Gasoline

630,000

Bare Steel Steel - Terminal Piping

None None

6/1/1954

Pressurized

64

Yes2805 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Report Generation Date: 12/12/2018 Page 584

Page 55: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

EXXONMOBIL BOZEMAN PRODUCTS TERMINAL

220 W GRIFFIN DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-08730

Operating Permit Renewal Date: 5/27/2019

Last Inspected On: 2/23/2016

Location:

Chris Martin, (406) 586-6927Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

19

Diesel

110

Bare Steel Steel

None None

1/1/1954

Pressurized

64

Yes2817 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Currently in Use

21

Gasoline

110

Bare Steel Steel

None None

1/1/1954

Pressurized

64

Yes2819 Yes

Impressed Current

Deferred MLLD Line Tightness Testing

Not Required

12/5/2015

10/6/2015

Currently in Use

30

Hazardous Substance

1,000

Bare Steel Steel

None Secondary Containment Chase

5/1/1994

Pressurized

24

Yes2828 Yes

Impressed Current

TLS-300 , Veeder Root

Deferred Continuous Interstitial Monitor

Continuous Interstitial Monitoring

12/15/2016

Currently in Use

34

Hazardous Substance

10,000

Bare Steel Steel

None Secondary Containment Chase

4/1/1991

Pressurized

27

Yes2824 Yes

Impressed Current

TLS-300 , Veeder Root

Deferred Continuous Interstitial Monitor

Continuous Interstitial Monitoring

12/15/2016

Currently in Use

35

Hazardous Substance

3,000

Bare Steel Steel

None Secondary Containment Chase

9/1/1987

Pressurized

31

Yes2825 Yes

Impressed Current

TLS-300 , Veeder Root

Deferred Continuous Interstitial Monitor

Continuous Interstitial Monitoring

12/15/2016

Report Generation Date: 12/12/2018 Page 585

Page 56: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

KAGY KORNER INC

1809 S TRACY AVE

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-09672

Operating Permit Renewal Date: 7/15/2020

Last Inspected On: 3/13/2017

Location:

Gary Tschache, (406) 586-1079Contact:

Owners/Operators: Kagy Korner Store Inc, Owner/Operator 1809 S TRACY AVEBOZEMAN MT 59715-5736

(406)-586-1079

Rhett Tschache, UST Class A Operator

Amber Wilkinson, UST Class A Operator

Rhett Tschache, UST Class B Operator

Amber Wilkinson, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

10,000

Cathodically Protected Steel Flexible Plastic

Double-Walled Double-Walled

11/15/1987

Pressurized

31

1462 Yes

High Level Alarm

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

6/22/2017

3/13/2017

3/13/2017

Currently in Use

2

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

Double-Walled Double-Walled

11/15/1987

Pressurized

31

1463 Yes

High Level Alarm

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

6/22/2017

3/13/2017

3/13/2017

Currently in Use

3

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

Double-Walled Double-Walled

11/15/1987

Pressurized

31

1464 Yes

High Level Alarm

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

6/22/2017

3/13/2017

3/13/2017

Report Generation Date: 12/12/2018 Page 586

Page 57: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

BOZEMAN DEACONESS HOSPITAL

915 HIGHLAND BLVD

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-09771

Operating Permit Renewal Date: 4/5/2020

Last Inspected On: 11/18/2016

Location:

Phil Sparks, (406) 585-5089Contact:

Owners/Operators: Bozeman Deaconess Hospital, Owner/Operator 915 HIGHLAND BLVDBOZEMAN MT 59715-6902

(406)-585-5089

William Buhl, UST Class A Operator

Jason Cocke, UST Class A Operator

William Buhl, UST Class B Operator

Jason Cocke, UST Class B Operator

Michael Dawson, UST Class B Operator

Jason Cocke, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

3

Diesel

8,000

Concrete Flexible Plastic

None Double-Walled

7/15/2004

U.S. Suction

14

Yes4940 Yes

Positive Shutoff, High Level Alarm

Not Applicable

Gilbarco EMC Basic , Gilbarco

Deferred Continuous Interstitial Monitor

Auto Dialer

10/21/2016

Report Generation Date: 12/12/2018 Page 587

Page 58: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

PANDA C STORE

621 BRIDGER DR

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

16-10193

Operating Permit Renewal Date: 7/31/2020

Last Inspected On: 5/23/2017

Location:

William Harston, (406) 587-6280Contact:

Owners/Operators: Panda Enterprises, Owner/Operator 621 BRIDGER DRBOZEMAN MT 59715-2205

(406)-587-6280

Panda Harston, UST Class A Operator

William P Harston, UST Class A Operator

Panda Harston, UST Class B Operator

William P Harston, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

1/5/1990

Safe Suction

28

3067 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Not Listed

Not Required

Currently in Use

2

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

1/5/1990

Safe Suction

28

3068 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Not Listed

Not Required

Currently in Use

3

Gasoline

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

1/5/1990

Safe Suction

28

4542 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Not Listed

Not Required

Report Generation Date: 12/12/2018 Page 588

Page 59: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

BLUE BASKET # 4

1035 REEVES RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-13115

Operating Permit Renewal Date: 6/30/2019

Last Inspected On: 2/15/2016

Location:

Michele LaVigne, (406) 586-5770Contact:

Owners/Operators: Blue Basket Markets Billings, Owner/Operator PO BOX 531BILLINGS MT 59103-0531

(406)-252-0166

Brit Miller, UST Class A Operator

Lori Anderson, UST Class B Operator

Carrie Hodges, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1993

Pressurized

25

456 Yes

High Level Alarm

Galvanic

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

1/18/2016

Currently in Use

2

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1993

Pressurized

25

457 Yes

High Level Alarm

Galvanic

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

1/18/2016

Currently in Use

3

Diesel

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1993

Pressurized

25

458 Yes

High Level Alarm

Galvanic

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

1/18/2016

Report Generation Date: 12/12/2018 Page 589

Page 60: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

CASEYS #5

4135 VALLEY COMMONS DR

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

16-13775

Operating Permit Renewal Date: 2/19/2020

Last Inspected On: 12/29/2016

Location:

Calvin Wilson, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Jason Shanley, Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Calvin Wilson, UST Class A Operator

Lisa Anderson, UST Class B Operator

David Lingenfelter, UST Class B Operator

Damian Lewis, UST Class B Global Operator

Kelly Scott Shutes, UST Class B Global Operator

Calvin Wilson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

12,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

3/1/1998

Pressurized

20

3407 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

8/7/2013

Currently in Use

2

Gasoline

12,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

3/1/1998

Pressurized

20

3408 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

8/7/2013

Currently in Use

3

Gasoline

12,000

Fiberglass Reinforced Plastic Flexible Plastic

None Double-Walled

3/1/1998

Pressurized

20

3409 Yes

Ball Float Valve

Not Applicable

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

8/7/2013

Report Generation Date: 12/12/2018 Page 590

Page 61: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

HOLIDAY STATIONSTORE 305

1951 DURSTON RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

56-13937

Operating Permit Renewal Date: 12/20/2019

Last Inspected On: 9/30/2016

Location:

Steve Ulery, (406) 585-3460Contact:

Owners/Operators: Rocky Mountain Oil LLC, Owner/Operator ATTN EVNIRONMENTAL MANAGER4567 AMERICAN BLVD WMINNEAPOLIS MN 55437

(952)-830-8899

Valeria Jeffries, UST Class A Operator

Chuck Nyberg, UST Class A Operator

Patrick Patnaude, UST Class A Operator

Stephen Reckinger, UST Class A Operator

Steve Ulery, UST Class B Operator

Jeff Reed, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

6/1/1999

Pressurized

19

4047 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

Yes10/2/2007

5/14/2010

Currently in Use

2

Gasoline

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

6/1/1999

Pressurized

19

4048 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

Yes10/2/2007

5/14/2010

Currently in Use

3

Gasoline

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

6/1/1999

Pressurized

19

4566 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

Yes10/2/2007

5/14/2010

Report Generation Date: 12/12/2018 Page 591

Page 62: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

HOLIDAY STATIONSTORE 305

1951 DURSTON RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

56-13937

Operating Permit Renewal Date: 12/20/2019

Last Inspected On: 9/30/2016

Location:

Steve Ulery, (406) 585-3460Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

6/1/1999

Pressurized

19

4567 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Electronic Line Leak Detector

Yes10/2/2007

5/14/2010

Currently in Use

5

Diesel

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

6/1/1999

Pressurized

19

4051 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

10/2/2007

5/14/2010

Report Generation Date: 12/12/2018 Page 592

Page 63: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

SIME CONSTRUCTION

190 RAMSHORN DR

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

56-13960

Operating Permit Renewal Date: 6/29/2019

Last Inspected On: 1/18/2016

Location:

Shawn Sime, (406) 580-1109Contact:

Owners/Operators: Sime Construction, Owner/Operator 190 RAMSHORN DRBOZEMAN MT 59718-8181

(406)-582-9841

Shawn Sime, UST Class A Operator

Matthew Wilmeth, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Waste Oil

2,000

Cathodically Protected Steel Flexible Plastic

Double-Walled Double-Walled

1/1/2000

U.S. Suction

18

4487 Yes

High Level Alarm

Galvanic

LDE Series , Pneumercator

Continuous Interstitial Monitor Continuous Interstitial Monitor

Continuous Interstitial Monitoring

5/15/2013

2/25/2013

Report Generation Date: 12/12/2018 Page 593

Page 64: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

COSTCO WHOLESALE GASOLINE BOZEMAN

2505 CATRON ST

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

60-15075

Operating Permit Renewal Date: 4/30/2020

Last Inspected On: 12/2/2016

Location:

(406) 585-0383Contact:

Owners/Operators: Costco Wholesale, Owner/Operator ATTN LICENSINGPO BOX 35005SEATTLE WA 98124-8990

(425)-313-8100

Devin Stewart, UST Class A Operator

Devin Stewart, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

30,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

10/24/2007

Pressurized

11

5130 Yes

High Level Alarm

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

2

Gasoline

30,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

10/24/2007

Pressurized

11

5131 Yes

High Level Alarm

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

3

Gasoline

30,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

10/24/2007

Pressurized

11

5132 Yes

High Level Alarm

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

4

Hazardous Substance

1,500

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

3/25/2011

Pressurized

07

5282 Yes

High Level Alarm

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

Yes11/17/2015

Report Generation Date: 12/12/2018 Page 594

Page 65: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

RESSLER MOTOR COMPANY

8474 HUFFINE LN

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

60-15102

Operating Permit Renewal Date: 8/18/2021

Last Inspected On: 7/9/2018

Location:

Richard Thomas, (406) 587-5501Contact:

Owners/Operators: Ressler Motors Company, Owner/Operator PO BOX 400BOZEMAN MT 59771-0400

(406)-587-5501

Chad Karch, UST Class A Operator

Dennis A Franks, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Waste Oil

1,100

Unknown Flexible Plastic

None Double-Walled

7/8/2008

Pressurized

10

Yes5178 Yes

Not Applicable

ILS-350 , Veeder Root

Deferred Continuous Interstitial Monitor

Auto Dialer

Yes

7/9/2018

Currently in Use

2

Waste Oil

1,100

Unknown Flexible Plastic

None Double-Walled

7/8/2008

Pressurized

10

Yes5179 Yes

High Level Alarm

Not Applicable

ILS-350 , Veeder Root

Deferred Continuous Interstitial Monitor

Auto Dialer

Yes

7/9/2018

Report Generation Date: 12/12/2018 Page 595

Page 66: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

TOWN PUMP INC BOZEMAN 5

29001 NORRIS RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

60-15119

Operating Permit Renewal Date: 10/27/2021

Last Inspected On: 5/17/2018

Location:

Don Edmisten, (406) 497-6700Contact:

Owners/Operators: Billings Holdings LLC, Owner/Operator PO BOX 6000BUTTE MT 59702-6000

(406)-497-6700

Don Edmisten, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

14,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/8/2008

Pressurized

10

5191 Yes

Ball Float Valve, Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

2

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/8/2008

Pressurized

10

5192 Yes

Ball Float Valve, Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

3

Gasoline

14,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/8/2008

Pressurized

10

5193 Yes

Ball Float Valve, Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Report Generation Date: 12/12/2018 Page 596

Page 67: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

TOWN PUMP INC BOZEMAN 5

29001 NORRIS RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

60-15119

Operating Permit Renewal Date: 10/27/2021

Last Inspected On: 5/17/2018

Location:

Don Edmisten, (406) 497-6700Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/8/2008

Pressurized

10

5194 Yes

Ball Float Valve, Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

5

Gasoline

20,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/8/2008

Pressurized

10

5195 Yes

Ball Float Valve, Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

6

Gasoline

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

6/6/2017

Pressurized

01

5736 Yes

Positive Shutoff

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Yes

5/15/2017

Report Generation Date: 12/12/2018 Page 597

Page 68: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

TOWN PUMP BOZEMAN 7

1871 BAXTER LN

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

60-15205

Operating Permit Renewal Date: 7/16/2019

Last Inspected On: 2/26/2016

Location:

Trent Biggers, (406) 497-6700Contact:

Owners/Operators: Montana Growth Opportunities LLC, Owner 600 S MAIN STBUTTE MT 59701

(406)-497-6700

Arnold Osmun, Operator 2917 STATE STBUTTE MT 59701

(406)-497-6946

Don Edmisten, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

2

Gasoline

20,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/1/2012

Pressurized

06

5348 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation

Stat. Inventory Reconcilitation

Stat. Inventory Reconcilitation

Electronic Line Leak Detector

Yes

Currently in Use

3

Gasoline

15,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/1/2012

Pressurized

06

5349 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation

Stat. Inventory Reconcilitation

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

4

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/1/2012

Pressurized

06

5350 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation

Stat. Inventory Reconcilitation

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Report Generation Date: 12/12/2018 Page 598

Page 69: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

TOWN PUMP BOZEMAN 7

1871 BAXTER LN

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

60-15205

Operating Permit Renewal Date: 7/16/2019

Last Inspected On: 2/26/2016

Location:

Trent Biggers, (406) 497-6700Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Diesel

15,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/1/2012

Pressurized

06

5351 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation

Stat. Inventory Reconcilitation

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Currently in Use

6

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

12/1/2012

Pressurized

06

5352 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation

Stat. Inventory Reconcilitation

Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Report Generation Date: 12/12/2018 Page 599

Page 70: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

SMITHS #170 FUEL CENTER

1735 W OAK ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

60-15234

Operating Permit Renewal Date: 6/16/2020

Last Inspected On: 4/11/2017

Location:

David Harris, (801) 974-1206Contact:

Owners/Operators: Smiths Food and Drug, Owner 1550 S REDWOOD RDSALT LAKE CITY UT 84104-5105

(801)-974-1529

David Harris, Operator PO BOX 244WINNETT MT 59087-0244

(801)-974-1206

Gary A Dotseth, UST Class A Operator

Todd Dotseth, UST Class A Operator

David Harris, UST Class A Operator

Ronnie Houtekamer, UST Class A Operator

Todd Dotseth, UST Class B Operator

Gary A Dotseth, UST Class B Global Operator

David Harris, UST Class B Global Operator

Ronnie Houtekamer, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

20,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

11/1/2013

Pressurized

05

5443 Yes

High Level Alarm

Not Applicable

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Not Listed

Electronic Line Leak Detector

Yes

Currently in Use

2

Diesel

10,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

11/1/2013

Pressurized

05

5444 Yes

High Level Alarm

Not Applicable

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Not Listed

Electronic Line Leak Detector

Yes

Report Generation Date: 12/12/2018 Page 600

Page 71: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

SMITHS #170 FUEL CENTER

1735 W OAK ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

60-15234

Operating Permit Renewal Date: 6/16/2020

Last Inspected On: 4/11/2017

Location:

David Harris, (801) 974-1206Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

3

Gasoline

8,000

Fiberglass Reinforced Plastic Flexible Plastic

Double-Walled Double-Walled

11/1/2013

Pressurized

05

5445 Yes

High Level Alarm

Not Applicable

TLS-450 , Veeder Root

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Not Listed

Electronic Line Leak Detector

Yes

Report Generation Date: 12/12/2018 Page 601

Page 72: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

BOZEMAN #8 TOWN PUMP

5050 S COTTONWOOD RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

60-15244

Operating Permit Renewal Date: 3/5/2021

Last Inspected On: 10/11/2017

Location:

Trent Biggers, (406) 497-6700Contact:

Owners/Operators: Park Street Holdings LLC, Owner/Operator PO BOX 6000BUTTE MT 59702-6000

(406)-467-6700

Don Edmisten, UST Class A Operator

Don Edmisten, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

20,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

8/1/2014

Pressurized

04

5479 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-450 , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

9/15/2014

Currently in Use

2

Gasoline

15,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

8/14/2014

Pressurized

04

5480 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-450 , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

9/15/2014

Currently in Use

3

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

8/14/2014

Pressurized

04

5481 Yes

Positive Shutoff

Not Applicable

TLS-450 , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

9/15/2014

Currently in Use

4

Diesel

15,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

8/14/2014

Pressurized

04

5482 Yes

Positive Shutoff

Not Applicable

TLS-450 , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

9/15/2014

Report Generation Date: 12/12/2018 Page 602

Page 73: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

BOZEMAN #8 TOWN PUMP

5050 S COTTONWOOD RD

Sys Fac ID:

BOZEMAN, MT 59718 GALLATIN

60-15244

Operating Permit Renewal Date: 3/5/2021

Last Inspected On: 10/11/2017

Location:

Trent Biggers, (406) 497-6700Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Diesel

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

Double-Walled Double-Walled

8/14/2014

Pressurized

04

5483 Yes

Positive Shutoff

Not Applicable

TLS-450 , Veeder Root

Continuous Interstitial Monitor, Stat. Inventory Reconcilitation, Approved Remote Monitoring

Stat. Inventory Reconcilitation, Approved Remote Monitoring

Continuous Interstitial Monitor, Not Listed

Electronic Line Leak Detector

9/15/2014

Report Generation Date: 12/12/2018 Page 603

Page 74: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of BOZEMAN

223 EAST MAIN ST

223 E MAIN ST

Sys Fac ID:

BOZEMAN, MT 59715 GALLATIN

60-15322

Operating Permit Renewal Date:

Last Inspected On:

Location:

Mark Stuart, (406) 579-3519Contact:

Owners/Operators: 223 E Main LLC, Owner/Operator 3600 BUTLER RDREISTERSTOWN MD 21136

(406)-579-3519

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Under Construction

1

Unknown

320

Bare Steel Steel

None None

Not Listed

5840 No

Not Listed Not Listed

Not Listed

Report Generation Date: 12/12/2018 Page 604

Page 75: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of GALLATIN GATEWAY

CASEYS #6

47650 GALLATIN RD

Sys Fac ID:

GALLATIN GATEWAY, MT 59730 GALLATIN

16-06923

Operating Permit Renewal Date: 9/10/2020

Last Inspected On: 3/22/2017

Location:

Calvin Wilson, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Damian Lewis, UST Class A Operator

Calvin Wilson, UST Class A Operator

Cheryl Caton, UST Class B Operator

Damian Lewis, UST Class B Operator

Barbara Pozega, UST Class B Operator

Amber Wiatt, UST Class B Operator

Kelly Scott Shutes, UST Class B Global Operator

Calvin Wilson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

Impressed Current Double-Walled

9/1/1985

Pressurized

33

4556 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/15/2016

3/22/2017

Currently in Use

2

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

Impressed Current Double-Walled

9/1/1985

Pressurized

33

4557 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/15/2016

3/22/2017

Report Generation Date: 12/12/2018 Page 605

Page 76: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of GALLATIN GATEWAY

CASEYS #6

47650 GALLATIN RD

Sys Fac ID:

GALLATIN GATEWAY, MT 59730 GALLATIN

16-06923

Operating Permit Renewal Date: 9/10/2020

Last Inspected On: 3/22/2017

Location:

Calvin Wilson, (406) 587-0702Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

3

Diesel

10,000

Cathodically Protected Steel Flexible Plastic

Impressed Current Double-Walled

9/1/1985

Pressurized

33

4558 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2, ELLD Line Tightness Testing

Continuous Interstitial Monitor

Electronic Line Leak Detector

11/15/2016

3/22/2017

Report Generation Date: 12/12/2018 Page 606

Page 77: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of GALLATIN GATEWAY

CASEYS #9

76250 GALLATIN RD

Sys Fac ID:

GALLATIN GATEWAY, MT 59730 GALLATIN

16-09998

Operating Permit Renewal Date: 2/20/2021

Last Inspected On: 11/29/2017

Location:

Calvin Wison, (406) 587-0702Contact:

Owners/Operators: Story Distributing Company, Owner/Operator PO BOX 1201BOZEMAN MT 59771-1201

(406)-587-0702

Jason Shanley, UST Class A Operator

Calvin Wilson, UST Class A Operator

Mari Cordova, UST Class B Operator

Kristy Saul, UST Class B Operator

Jason Shanley, UST Class B Operator

Calvin Wilson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

11/19/1993

Pressurized

25

4496 Yes

Ball Float Valve

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/19/2017

3/7/2017

Currently in Use

2

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

11/19/1993

Pressurized

25

4494 Yes

Ball Float Valve

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/19/2017

3/7/2017

Currently in Use

3

Gasoline

8,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

11/19/1993

Pressurized

25

4495 Yes

Ball Float Valve

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/19/2017

3/7/2017

Currently in Use

4

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

11/19/1993

Pressurized

25

4492 Yes

Ball Float Valve

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/19/2017

3/7/2017

Report Generation Date: 12/12/2018 Page 607

Page 78: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of GALLATIN GATEWAY

CASEYS #9

76250 GALLATIN RD

Sys Fac ID:

GALLATIN GATEWAY, MT 59730 GALLATIN

16-09998

Operating Permit Renewal Date: 2/20/2021

Last Inspected On: 11/29/2017

Location:

Calvin Wison, (406) 587-0702Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Diesel

6,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

11/19/1993

Pressurized

25

4493 Yes

Ball Float Valve

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

11/19/2017

3/7/2017

Report Generation Date: 12/12/2018 Page 608

Page 79: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of MANHATTAN

DANHOF CHEVROLET INC

6605 AMSTERDAM RD

Sys Fac ID:

MANHATTAN, MT 59741 GALLATIN

16-01367

Operating Permit Renewal Date: 4/16/2021

Last Inspected On: 12/8/2017

Location:

Joe Danhof, (406) 282-7231Contact:

Owners/Operators: Danhof Chevrolet Inc, Owner/Operator 6605 AMSTERDAM RDMANHATTAN MT 59741-8315

(406)-282-7231

Wayne Klompien, UST Class A Operator

Dennis A Franks, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

9

Diesel

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

6/13/1986

Pressurized

32

800 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

4/14/2015

8/10/2017

Currently in Use

10

Gasoline

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

6/13/1986

Pressurized

32

801 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

4/14/2015

8/10/2017

Currently in Use

11

Gasoline

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

6/13/1986

Pressurized

32

802 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

4/14/2015

8/10/2017

Currently in Use

12

Gasoline

8,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

12/1/1998

Pressurized

20

3592 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

4/14/2015

8/10/2017

Report Generation Date: 12/12/2018 Page 609

Page 80: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of MANHATTAN

DANHOF CHEVROLET INC

6605 AMSTERDAM RD

Sys Fac ID:

MANHATTAN, MT 59741 GALLATIN

16-01367

Operating Permit Renewal Date: 4/16/2021

Last Inspected On: 12/8/2017

Location:

Joe Danhof, (406) 282-7231Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

13

Diesel

4,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

12/1/1998

Pressurized

20

3593 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

4/14/2015

8/10/2017

Report Generation Date: 12/12/2018 Page 610

Page 81: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of MANHATTAN

THRIFTWAY SUPER STOP 12 (ME & JAN'S MINI MART III)

404 S BROADWAY ST

Sys Fac ID:

MANHATTAN, MT 59741 GALLATIN

16-03431

Operating Permit Renewal Date: 6/12/2019

Last Inspected On: 6/1/2016

Location:

Louis Sutey, (406) 494-2305Contact:

Owners/Operators: Sutey Oil Co Inc, Owner/Operator 2000 HOLMES AVEBUTTE MT 59701-3553

(406)-494-2305

Bryan Kelsey, UST Class A Operator

Louis Sutey, UST Class A Operator

Melissa Damuth, UST Class B Operator

Bryan Kelsey, UST Class B Operator

Dottie Nichols, UST Class B Operator

Dave Stine, UST Class B Operator

Louis Sutey, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

12,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None Double-Walled

5/1/1997

Pressurized

21

809 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Electronic Line Leak Detector5/1/2007

Currently in Use

5

Diesel

8,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None Double-Walled

5/1/1997

Pressurized

21

810 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Electronic Line Leak Detector5/1/2007

Currently in Use

6

Diesel

5,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None Double-Walled

5/1/1997

Pressurized

21

811 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Electronic Line Leak Detector5/1/2007

Report Generation Date: 12/12/2018 Page 611

Page 82: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of MANHATTAN

THRIFTWAY SUPER STOP 12 (ME & JAN'S MINI MART III)

404 S BROADWAY ST

Sys Fac ID:

MANHATTAN, MT 59741 GALLATIN

16-03431

Operating Permit Renewal Date: 6/12/2019

Last Inspected On: 6/1/2016

Location:

Louis Sutey, (406) 494-2305Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

7

Gasoline

15,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None Double-Walled

12/4/2007

Pressurized

11

5124 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2, Continuous Interstitial Monitor

Electronic Line Leak Detector

Yes

Report Generation Date: 12/12/2018 Page 612

Page 83: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of MANHATTAN

SCHUTTER SEED FARM, INC

3627 WOODEN SHOE RD

Sys Fac ID:

MANHATTAN, MT 59741 GALLATIN

16-10184

Operating Permit Renewal Date: 3/26/2021

Last Inspected On: 12/19/2017

Location:

Sid Schutter, (406) 539-6478Contact:

Owners/Operators: Sid Schutter Farm Inc, Owner 3131 WOODEN SHOE RDMANHATTAN MT 59741

(406)-539-6478

Sid Schutter, Operator 3131 WOODEN SHOE RDMANHATTAN MT 59741

(406)-284-6478

Sid Schutter, UST Class A Operator

Dennis A Franks, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

2

Diesel

2,000

Cathodically Protected Steel Steel

None Double-Walled

1/1/1994

Safe Suction

24

1909 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Deferred

Not Required

12/21/2017

Currently in Use

3

Diesel

10,000

Cathodically Protected Steel Steel

None Double-Walled

1/1/1994

Safe Suction

24

1910 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 Deferred

Not Required

12/21/2017

Report Generation Date: 12/12/2018 Page 613

Page 84: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of MANHATTAN

HARLOWS SCHOOL BUS SVC

1085 YADON RD

Sys Fac ID:

MANHATTAN, MT 59741 GALLATIN

56-13969

Operating Permit Renewal Date:

Last Inspected On: 3/31/2017

Location:

Hal Illum, (406) 284-4055Contact:

Owners/Operators: HJJ Properties LLC, Owner PO BOX 1781085 YADON RDMANHATTAN MT 59741

(406)-284-4055

Justin Hageness, Operator PO BOX 1781085 YADON RDMANHATTAN MT 59741

(406)-284-4055

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Temporarily Out of Use

1

Diesel

1,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

12/30/1999

Safe Suction

18

4142 Yes

High Level Alarm

Galvanic

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Not Listed

Not Required

3/31/2017

Temporarily Out of Use

2

Diesel

500

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

12/30/1999

Safe Suction

18

4143 Yes

High Level Alarm

Galvanic

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Not Listed

Not Required

3/31/2017

Report Generation Date: 12/12/2018 Page 614

Page 85: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of THREE FORKS

THRIFTWAY CONOCO 15

105 MAIN ST

Sys Fac ID:

THREE FORKS, MT 59752 GALLATIN

16-00987

Operating Permit Renewal Date: 6/12/2019

Last Inspected On: 5/31/2016

Location:

Louis Sutey, (406) 494-2305Contact:

Owners/Operators: Sutey Oil Co Inc, Owner/Operator 2000 HOLMES AVEBUTTE MT 59701-3553

(406)-494-2305

Bryan Kelsey, UST Class A Operator

Louis Sutey, UST Class A Operator

Bryan Kelsey, UST Class B Operator

Gayle Ross, UST Class B Operator

Dave Stine, UST Class B Operator

Louis Sutey, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1994

Pressurized

24

523 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/20/2016

4/10/2018

Currently in Use

2

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1994

Pressurized

24

524 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/20/2016

4/10/2018

Currently in Use

3

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1994

Pressurized

24

525 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/20/2016

4/10/2018

Report Generation Date: 12/12/2018 Page 615

Page 86: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of THREE FORKS

THRIFTWAY CONOCO 15

105 MAIN ST

Sys Fac ID:

THREE FORKS, MT 59752 GALLATIN

16-00987

Operating Permit Renewal Date: 6/12/2019

Last Inspected On: 5/31/2016

Location:

Louis Sutey, (406) 494-2305Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1994

Pressurized

24

526 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/20/2016

4/10/2018

Currently in Use

11

Gasoline

12,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1994

Pressurized

24

520 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/20/2016

4/10/2018

Currently in Use

12

Gasoline

3,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1994

Pressurized

24

521 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/20/2016

4/10/2018

Currently in Use

13

Gasoline

3,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/1/1994

Pressurized

24

522 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

4/20/2016

4/10/2018

Report Generation Date: 12/12/2018 Page 616

Page 87: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

CORNER CENEX

136 N CANYON ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-00055

Operating Permit Renewal Date: 9/5/2020

Last Inspected On: 5/15/2017

Location:

Brad Schmier, (406) 640-1241Contact:

Owners/Operators: Jerrys Enterprises Inc, Owner PO BOX 669WEST YELLOWSTONE MT 59758-0669

(406)-646-7735

J Douglas Schmier, Operator

Timothy Heideman, UST Class A Operator

Brad Schmier, UST Class A Operator

Timothy Heideman, UST Class B Operator

Brad Schmier, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

10/1/1991

Pressurized

27

2263 Yes

Flapper Valve (Auto Shutoff)

Galvanic

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

ELLD Line Tightness Testing

Electronic Line Leak Detector

5/15/2017

5/16/2017

Currently in Use

2

Diesel

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

10/1/1991

Pressurized

27

2264 Yes

Flapper Valve (Auto Shutoff)

Galvanic

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

ELLD Line Tightness Testing

Electronic Line Leak Detector

5/15/2017

5/16/2017

Currently in Use

3

Gasoline

6,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

10/1/1991

Pressurized

27

2265 Yes

Flapper Valve (Auto Shutoff)

Galvanic

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

ELLD Line Tightness Testing

Electronic Line Leak Detector

5/15/2017

5/16/2017

Report Generation Date: 12/12/2018 Page 617

Page 88: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

CORNER CENEX

136 N CANYON ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-00055

Operating Permit Renewal Date: 9/5/2020

Last Inspected On: 5/15/2017

Location:

Brad Schmier, (406) 640-1241Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

10/1/1991

Pressurized

27

2266 Yes

Flapper Valve (Auto Shutoff)

Galvanic

Gilbarco EMC Basic , Gilbarco

Automatic Tank Gauging 0.2 Automatic Tank Gauging 0.2

ELLD Line Tightness Testing

Electronic Line Leak Detector

5/15/2017

5/16/2017

Report Generation Date: 12/12/2018 Page 618

Page 89: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

WESTGATE STATION

11 YELLOWSTONE AVE

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-03734

Operating Permit Renewal Date: 1/14/2021

Last Inspected On: 10/10/2017

Location:

(406) 646-7654Contact:

Owners/Operators: Westgate Station, Owner/Operator PO BOX 1769WEST YELLOWSTONE MT 59758-1769

(406)-646-7651

Cole Parker, UST Class A Operator

Cole Parker, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

9

Gasoline

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

10/1/1998

Pressurized

20

3108 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

10/8/2014

Currently in Use

10

Gasoline

10,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

10/1/1998

Pressurized

20

3109 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

10/10/2017

Currently in Use

11

Gasoline

6,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

10/1/1998

Pressurized

20

3110 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

10/10/2017

Currently in Use

12

Diesel

5,000

Fiberglass Reinforced Plastic Fiberglass Reinforced Plastic

None None

10/1/1998

Pressurized

20

3111 Yes

Ball Float Valve

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

10/10/2017

Report Generation Date: 12/12/2018 Page 619

Page 90: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

MDOT DUCK CREEK (WEST YELLOWSTONE)

8060 GALLATIN RD

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-04057

Operating Permit Renewal Date: 3/25/2021

Last Inspected On: 10/11/2017

Location:

Greg Johnson, (406) 646-7268Contact:

Owners/Operators: MDOT Helena, Owner MIKE MUROLOPO BOX 201001HELENA MT 59620-1001

(406)-444-6200

Greg Johnson, Operator 260 PELICAN LNWEST YELLOWSTONE MT 59758

(406)-640-1664

Jeff Gleason, UST Class A Operator

Walt Kerttula, UST Class A Operator

Mike Murolo, UST Class A Operator

Joe Radonich, UST Class A Operator

Jacob Holthues, UST Class B Operator

Greg Johnson, UST Class B Global Operator

Joe Radonich, UST Class B Global Operator

Ken Whitaker, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Gasoline

2,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

Double-Walled None

7/1/1992

Safe Suction

26

4323 Yes

Flapper Valve (Auto Shutoff)

Galvanic

ILS-350 , Veeder Root

Continuous Interstitial Monitor Deferred

Not Required

10/11/2017

Currently in Use

7

Diesel

6,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

Double-Walled None

7/1/1992

Safe Suction

26

4324 Yes

Flapper Valve (Auto Shutoff)

Galvanic

ILS-350 , Veeder Root

Continuous Interstitial Monitor Deferred

Not Required

10/11/2017

Report Generation Date: 12/12/2018 Page 620

Page 91: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

TWO TOP SNOWMOBILE RENTAL

645 GIBBON AVE

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-04445

Operating Permit Renewal Date: 2/27/2021

Last Inspected On: 11/9/2017

Location:

David McCray, (406) 646-7802Contact:

Owners/Operators: Two Top Snowmobile Rental Inc, Owner/Operator PO BOX 798WEST YELLOWSTONE MT 59758-0798

(406)-646-7802

David McCray, UST Class A Operator

Kennedy Brown, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

4,000

Cathodically Protected Steel Steel

None none

9/1/1992

Safe Suction

26

1598 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Not Listed

Not Required

10/10/2017

Report Generation Date: 12/12/2018 Page 621

Page 92: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

RIVERSIDE STATION

215 N CANYON ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-04500

Operating Permit Renewal Date: 8/2/2020

Last Inspected On: 5/15/2017

Location:

Brad or Doug Schmier, (406) 646-7735Contact:

Owners/Operators: Jerrys Enterprises Inc, Owner PO BOX 669WEST YELLOWSTONE MT 59758-0669

(406)-646-7735

Bradley Schmier, Operator PO BOX 669WEST YELLOWSTONE MT 59758-0669

(406)-646-7735

Bradley Schmier, UST Class A Operator

Bradley Schmier, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Gasoline

12,000

Steel Clad Flexible Plastic

Double-Walled Double-Walled

1/1/1999

Pressurized

19

3684 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

4/25/2017

Currently in Use

6

Gasoline

8,000

Steel Clad Flexible Plastic

Double-Walled Double-Walled

1/1/1999

Pressurized

19

3685 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

4/21/2017

Currently in Use

7

Diesel

4,000

Steel Clad Flexible Plastic

Double-Walled Double-Walled

1/1/1999

Pressurized

19

3686 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-350/Gilbarco EMC , Veeder Root

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Automatic Tank Gauging 0.1, Automatic Tank Gauging 0.2

Continuous Interstitial Monitor

Electronic Line Leak Detector

4/19/2017

Report Generation Date: 12/12/2018 Page 622

Page 93: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

SUPER SAVE CONOCO

138 FIREHOLE LN BOX 669

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-04501

Operating Permit Renewal Date: 8/2/2020

Last Inspected On: 5/15/2017

Location:

Brad Schmier, (406) 646-7735Contact:

Owners/Operators: Jerrys Enterprises Inc, Owner/Operator PO BOX 669WEST YELLOWSTONE MT 59758-0669

(406)-646-7735

Bradley Schmier, UST Class A Operator

Bradley Schmier, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

12/11/1989

Pressurized

28

1414 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/10/2016

Currently in Use

6

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

12/11/1989

Pressurized

28

4302 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/10/2016

Currently in Use

7

Gasoline

6,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

12/11/1989

Pressurized

28

1416 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/10/2016

Currently in Use

8

Diesel

6,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

6/1/1994

Pressurized

24

1417 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/10/2016

Report Generation Date: 12/12/2018 Page 623

Page 94: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

DELAWARE NORTH PARKS SERVICES AT YELLOWSTONE LLC

251 ECHO CANYON RD

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-06367

Operating Permit Renewal Date: 10/1/2019

Last Inspected On: 6/9/2016

Location:

Robbie Hermanson, (406) 586-7593Contact:

Owners/Operators: Delaware North Companies Inc, Owner 250 DELAWARE AVEBUFFALO NY 14202

(406)-586-7593

Delaware North Parks Services at Yellowstone LLC, Operator 8358 HUFFINE LN #2BOZEMAN MT 59718

(406)-586-7593

Justin Cook, UST Class A Operator

Fatouros Fatouros, UST Class A Operator

Jason Fatouros, UST Class A Operator

Ron Wilkes, UST Class A Operator

Alexandra Chipouras, UST Class B Operator

Justin Cook, UST Class B Operator

Jason Fatouros, UST Class B Operator

Ron Wilkes, UST Class B Operator

Fatouros Fatouros, UST Class B Global Operator

Jason Fatouros, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Gasoline

6,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

Double-Walled Double-Walled

6/1/1993

Pressurized

25

1277 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

Manual Interstitial Monitor MLLD Line Tightness Testing

Mechanical Line Leak Detector

6/9/2016

10/14/2015

Currently in Use

6

Diesel

2,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

Double-Walled Double-Walled

6/1/1993

Pressurized

25

1278 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

Manual Interstitial Monitor MLLD Line Tightness Testing

Mechanical Line Leak Detector

6/9/2016

10/14/2015

Report Generation Date: 12/12/2018 Page 624

Page 95: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

EAGLE STORE UST

3 CANYON ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-08570

Operating Permit Renewal Date: 10/8/2020

Last Inspected On: 5/15/2017

Location:

Eva Eagle, (406) 646-9300Contact:

Owners/Operators: Eagle Company Inc, Owner/Operator PO BOX 280WEST YELLOWSTONE MT 59758-0280

(406)-646-9300

Eva Eagle, UST Class A Operator

Anna Kessler, UST Class A Operator

Marlys Merna, UST Class A Operator

Josh Babros, UST Class B Operator

Jamie Benes, UST Class B Operator

Marlys Merna, UST Class B Operator

Lee Sloan, UST Class B Operator

Anna Kessler, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Gasoline

8,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/28/1989

Pressurized

29

3986 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/12/2016

Currently in Use

7

Gasoline

8,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

4/28/1989

Pressurized

29

3987 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/12/2016

Currently in Use

8

Gasoline

4,000

Steel Clad Fiberglass Reinforced Plastic

None None

10/20/1997

Pressurized

21

843 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

10/12/2016

Report Generation Date: 12/12/2018 Page 625

Page 96: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

EAGLE SERVICE UST

17 CANYON ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-08571

Operating Permit Renewal Date: 10/8/2020

Last Inspected On: 5/15/2017

Location:

Karen Eagle, (406) 646-9300Contact:

Owners/Operators: Eagle Company Inc, Owner/Operator PO BOX 280WEST YELLOWSTONE MT 59758-0280

(406)-646-9300

Eva Eagle, UST Class A Operator

Marlys Merna, UST Class A Operator

Josh Babros, UST Class B Operator

Jamie Benes, UST Class B Operator

Marlys Merna, UST Class B Operator

Lee Sloan, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

2

Gasoline

10,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

10/5/1990

Pressurized

28

844 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/12/2016

Currently in Use

3

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

10/5/1990

Pressurized

28

845 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/12/2016

Currently in Use

7

Gasoline

10,000

Steel Clad Fiberglass Reinforced Plastic

None None

6/1/1999

Pressurized

19

4018 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/12/2016

Report Generation Date: 12/12/2018 Page 626

Page 97: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

EAGLE SERVICE UST

17 CANYON ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-08571

Operating Permit Renewal Date: 10/8/2020

Last Inspected On: 5/15/2017

Location:

Karen Eagle, (406) 646-9300Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

8

Gasoline

10,000

Steel Clad Fiberglass Reinforced Plastic

None None

6/1/1999

Pressurized

19

4019 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/15/2017

10/12/2016

Report Generation Date: 12/12/2018 Page 627

Page 98: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

WEST ENTRANCE BLDG 458

W ENTRANCE BLDG 458

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-08870

Operating Permit Renewal Date: 9/13/2019

Last Inspected On: 6/2/2016

Location:

Tim Hudson, (307) 344-7381Contact:

Owners/Operators: National Park Service, Owner/Operator PO BOX 168MAMMOTH WY 82190-0168

(307)-344-2333

Harry Laney, UST Class A Operator

Claude W Long, UST Class A Operator

Harry Laney, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

4,000

Cathodically Protected Steel Steel

Double-Walled PVC

8/24/1988

Safe Suction

30

1740 Yes

Flapper Valve (Auto Shutoff)

Galvanic

EECO 1000 , EMCO Electronics

Continuous Interstitial Monitor Deferred

Not Required

5/19/2016

Currently in Use

2

Diesel

4,000

Cathodically Protected Steel Steel

Double-Walled PVC

8/24/1988

Safe Suction

30

1739 Yes

Flapper Valve (Auto Shutoff)

Galvanic

EECO 1000 , EMCO Electronics

Continuous Interstitial Monitor Deferred

Not Required

5/19/2016

Report Generation Date: 12/12/2018 Page 628

Page 99: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

TRAVELERS SERVICE CENTER

26 ELECTRIC ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-09852

Operating Permit Renewal Date: 8/6/2020

Last Inspected On: 5/16/2017

Location:

Brad Loomis, (406) 646-9332Contact:

Owners/Operators: Loomis Enterprises Inc, Owner/Operator PO BOX 1110WEST YELLOWSTONE MT 59758-1110

(406)-646-7773

Bradley Loomis, UST Class A Operator

Bradley Loomis, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

4

Gasoline

10,000

Steel Clad Flexible Plastic

Double-Walled Double-Walled

4/21/1998

Pressurized

20

1555 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

10/13/2016

Currently in Use

5

Gasoline

10,000

Steel Clad Flexible Plastic

Double-Walled Double-Walled

4/21/1998

Pressurized

20

1556 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

10/13/2016

Currently in Use

6

Diesel

6,000

Steel Clad Flexible Plastic

Double-Walled Double-Walled

4/21/1998

Pressurized

20

1557 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

10/13/2016

Report Generation Date: 12/12/2018 Page 629

Page 100: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

ECONO MART

307 FIREHOLE AVE

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-10356

Operating Permit Renewal Date: 3/3/2021

Last Inspected On: 10/10/2017

Location:

Merrick Young, (406) 648-1704Contact:

Owners/Operators: Firehole Holdings LLC, Owner/Operator PO BOX 257WEST YELLOWSTONE MT 59758-0257

(406)-646-7887

Merrick Young, UST Class A Operator

Merrick Young, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

Lined Interior/Impressed Current Double-Walled

2/11/1975

Pressurized

43

847 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

10/13/2015

10/10/2017

Currently in Use

2

Gasoline

10,000

Cathodically Protected Steel Flexible Plastic

Lined Interior/Impressed Current Double-Walled

2/11/1975

Pressurized

43

848 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

10/13/2015

10/10/2017

Currently in Use

4

Gasoline

2,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

Lined Interior/Impressed Current Double-Walled

2/11/1975

Pressurized

43

850 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Continuous Interstitial Monitor

Mechanical Line Leak Detector

10/13/2015

10/10/2017

Currently in Use

5

Diesel

5,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

Lined Interior/Impressed Current None

2/11/1975

Pressurized

43

851 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

10/13/2015

10/10/2017

Report Generation Date: 12/12/2018 Page 630

Page 101: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

ECONO MART

307 FIREHOLE AVE

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-10356

Operating Permit Renewal Date: 3/3/2021

Last Inspected On: 10/10/2017

Location:

Merrick Young, (406) 648-1704Contact:

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Diesel

2,000

Steel Clad Flexible Plastic

Double-Walled Double-Walled

10/1/2001

Pressurized

17

4438 Yes

Flapper Valve (Auto Shutoff)

Not Applicable

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Manual Interstitial Monitor

Mechanical Line Leak Detector

10/10/2017

Report Generation Date: 12/12/2018 Page 631

Page 102: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

THREE BEAR LODGE INC

217 YELLOWSTONE AVE

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-10357

Operating Permit Renewal Date: 7/3/2020

Last Inspected On: 5/15/2017

Location:

Clyde Seely, (406) 646-7353Contact:

Owners/Operators: Clyde Seely, Owner/Operator PO BOX 1590WEST YELLOWSTONE MT 59758-1590

(406)-646-7365

Merrick Young, UST Class A Operator

Merrick Young, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

2

Gasoline

6,000

Cathodically Protected Steel Steel

None none

10/1/1993

Pressurized

25

2114 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

5/12/2014

10/11/2016

Report Generation Date: 12/12/2018 Page 632

Page 103: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

YELLOWSTONE ARCTIC YAMAHA ELECTRIC ST

208 ELECTRIC ST

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-10358

Operating Permit Renewal Date: 10/14/2021

Last Inspected On: 6/25/2018

Location:

Bill Howell, (406) 646-9636Contact:

Owners/Operators: William Howell, Owner/Operator PO BOX 350WEST YELLOWSTONE MT 59758-0350

(406)-646-9636

William Howell, UST Class A Operator

William Howell, UST Class B Operator

William Howell, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

2

Gasoline

6,000

Cathodically Protected Steel Steel

Impressed Current None

9/1/1992

Safe Suction

26

2305 Yes

Flapper Valve (Auto Shutoff)

Impressed Current

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Deferred

Not Required

10/13/2015

Report Generation Date: 12/12/2018 Page 633

Page 104: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

KIRKWOOD RANCH MOTEL TRAILER PARK

35 KIRKWOOD CREEK RD

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-10793

Operating Permit Renewal Date: 5/25/2020

Last Inspected On: 5/17/2017

Location:

Suan Chow, (406) 646-7200Contact:

Owners/Operators: E I Holdings LLC, Owner/Operator PO BOX 65906SALT LAKE CITY UT 84165

(801)-916-6605

Kyle Burden, UST Class A Operator

Chris Swenson, UST Class A Operator

Kyle Burden, UST Class B Operator

Chris Swenson, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

5

Gasoline

6,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

8/1/2000

Pressurized

18

4237 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.1 Continuous Interstitial Monitor

Continuous Interstitial Monitoring

5/16/2017

5/16/2017

5/16/2017

Currently in Use

6

Gasoline

2,000

Cathodically Protected Steel Flexible Plastic

None Double-Walled

8/1/2000

Pressurized

18

4580 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.1 Continuous Interstitial Monitor

Continuous Interstitial Monitoring

5/16/2017

5/16/2017

5/16/2017

Report Generation Date: 12/12/2018 Page 634

Page 105: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

YELLOWSTONE HOLIDAY RESORT

16990 HEBGEN LAKE RD PO BOX 759

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-11066

Operating Permit Renewal Date: 3/9/2022

Last Inspected On: 10/18/2018

Location:

Ellen Hodsgon, (801) 467-3600Contact:

Owners/Operators: Grayling Partners LC, Owner/Operator 2159 S 700 E STE 200SALT LAKE CITY UT 84106

(801)-467-3600

Bradley Campbell, UST Class A Operator

James Hynes, UST Class B Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

6

Gasoline

1,500

Concrete Fiberglass

None Double-Walled

10/1/1999

Pressurized

19

Yes4132 Yes

Not Applicable, Not Applicable

Gilbarco EMC Basic , Gilbarco

Deferred Continuous Interstitial Monitor

Continuous Interstitial Monitoring

10/18/2018

Report Generation Date: 12/12/2018 Page 635

Page 106: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

DNC PARKS AND RESORTS AT YELLOWSTONE ADVENTURES

415 YELLOWSTONE AVE

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-11619

Operating Permit Renewal Date: 10/19/2021

Last Inspected On: 10/2/2018

Location:

Jason Fatouros, (406) 586-7593Contact:

Owners/Operators: Delaware North Companies Inc, Owner 250 DELAWARE AVEBUFFALO NY 14202

(406)-586-7593

DNC Parks & Resorts Yellowstone Adventures, Operator 415 YELLOWSTONE AVEWEST YELLOWSTONE MT 59758

(406)-656-9564

Erik Dawkins, UST Class A Operator

Fatouros Fatouros, UST Class A Operator

Jason Fatouros, UST Class A Operator

David Singleton, UST Class A Operator

Ron Wilkes, UST Class A Operator

Alexandra Chipouras, UST Class B Operator

Justin Cook, UST Class B Operator

Erik Dawkins, UST Class B Operator

Justin Cook, UST Class B Global Operator

Fatouros Fatouros, UST Class B Global Operator

Jason Fatouros, UST Class B Global Operator

David Singleton, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Gasoline

4,000

Cathodically Protected Steel Steel

None none

10/1/1993

Safe Suction

25

2350 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 Deferred

Not Required

10/2/2018

Report Generation Date: 12/12/2018 Page 636

Page 107: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

LIONSHEAD RESORT

1545 TARGHEE PASS HWY

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-12923

Operating Permit Renewal Date:

Last Inspected On: 5/8/2018

Location:

Jerry Oksa, (406) 646-9584Contact:

Owners/Operators: Yellowstone Rental Properties LLC, Owner/Operator 547 GARDEN AVEBILLINGS MT 59101-5735

(406)-646-7606

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Temporarily Out of Use

2

Gasoline

10,000

Cathodically Protected Steel Steel

None none

11/1/1992

Safe Suction

26

3391 Yes

Flapper Valve (Auto Shutoff)

Galvanic

Vapor Monitoring Deferred

Not Required

5/8/2018

Report Generation Date: 12/12/2018 Page 637

Page 108: Facility Summary in GALLATIN County in the City of BELGRADEdeq.mt.gov/Portals/112/Land/UST/Documents/FacSumSheets/Gallatin.pdf · Owners/Operators: Great Falls Holdings LLC, Owner/Operator

Facility Summary in GALLATIN County in the City of WEST YELLOWSTONE

DNC PARKS & RESORTS OF WEST YELLOWSTONE

315 YELLOWSTONE AVE

Sys Fac ID:

WEST YELLOWSTONE, MT 59758 GALLATIN

16-13528

Operating Permit Renewal Date: 3/30/2022

Last Inspected On: 10/30/2018

Location:

Mark Walkup, (406) 646-7365Contact:

Owners/Operators: Delaware North Companies Inc, Owner 250 DELAWARE AVEBUFFALO NY 14202

(406)-586-7593

DNC Parks & Resorts Yellowstone Adventures, Operator 415 YELLOWSTONE AVEWEST YELLOWSTONE MT 59758

(406)-656-9564

Justin Cook, UST Class A Operator

Erik Dawkins, UST Class A Operator

Fatouros Fatouros, UST Class A Operator

Jason Fatouros, UST Class A Operator

David Singleton, UST Class A Operator

Ron Wilkes, UST Class A Operator

Alexandra Chipouras, UST Class B Operator

Justin Cook, UST Class B Operator

Erik Dawkins, UST Class B Global Operator

Fatouros Fatouros, UST Class B Global Operator

Jason Fatouros, UST Class B Global Operator

David Singleton, UST Class B Global Operator

Ron Wilkes, UST Class B Global Operator

Tank Id

Status

Product

Capacity

InstalledAge Tank Material of Construction Piping Material

Piping Type

Secondary Option Secondary OptionTag Number AST Spill Protected

Overfill Types

CP Met Types

ATG Type

Tank Detection Primary Pipe Detection

Secondary Pipe Detection

Catastrophic L.D. Type 3.0

Vapor Recovery

Energy Act

Sump Tightness

Inventory Control

Tank/Pipe CP

Line Tightness

Currently in Use

1

Diesel

4,000

Cathodically Protected Steel Fiberglass Reinforced Plastic

None None

9/10/1994

Pressurized

24

2306 Yes

Flapper Valve (Auto Shutoff)

Galvanic

TLS-300 , Veeder Root

Automatic Tank Gauging 0.2 MLLD Line Tightness Testing

Mechanical Line Leak Detector

6/13/2018

6/13/2018

Report Generation Date: 12/12/2018 Page 638