TRANSCRIPT
-
High Pressure Air Compressors
Capacity Testing of Valves
Bullets for storing Air under 50 bar pressure
Bullets for storing Air under 100 bar pressure
CNC machines for machining Castings & Bars
CNC machines for machining Castings & Bars
-
Index
SECTION DESCRIPTION PAGE No.LISTNo.
GENERAL INFORMATION
Method of Model Numbering
General Arrangement & Assembly Drawing
Standard Materials
Overall Dimensions
Discharge Capacities
Accessories
Instructions for Installation
Method of Model Numbering
General Arrangement Drawing
Standard Materials
Overall Dimensions
Discharge Capacities
Accessories
Instructions for Installation
1
2
3
4
5
6
7
1
2
3
4
5
6
7
2/01
2/02, 2/03
2/04
2/05
2/06, 2/07, 2/08
2/09 to 2/12
2/13 to 2/16
3
3/02
3/03
3/04
3/05, 3/06
Refer to 2/09 to 2/12
Refer to 2/13, 2/14, 2/15
/01
VALVE TYPE FL 441 (STANDARD PRESSURE SERIES)
VALVE TYPE FL 441 (HIGH PRESSURE SERIES)
3
2
1
FAINGER LESER 2011
1
2
1/01, 1/02
1/03
General Information
Selection of Valve Types
Method of Model Numbering
General Arrangement & Assembly Drawing
Standard Materials
Discharge Capacities
Overall Dimensions
Accessories
Instructions for Installation
1
2
3
4
5
6
7
4
4/02, 4/03
4/04,
4/05
4/05
Refer to 6/09, 6/10
Refer to 2/13, 2/14, 2/15
/01
VALVE TYPE FL 459 SERIES
4
I
-
Index
SECTION DESCRIPTION PAGE No.LISTNo.
Method of Model Numbering
General Arrangement & Assembly Drawing
Standard Materials
Overall Dimensions
Discharge Capacities
Accessories
Instructions for Installation
1
2
3
4
5
6
7
6/01
6/02, 6/03, 6/04
6/05
6/06
6/07
6/09, 6/10
Refer to 2/13, 2/14, 2/15
VALVE TYPE FL 549 SERIES
6
FAINGER LESER 2011
Sizing Calculations Acc. to AD-Merkblatt 2000-A2, ISO 4126
Sizing Calculations Acc. to ASME Sec. VIII, Div. 1/API RP 520
Sizing Calculations Acc. to IBR 1950
Standard Specification Sheet
1
2
3
4
7/01
7/02, to 7/06
7/07
7/08
SIZING OF SAFETY VALVES
7
II
Method of Model Numbering
General Arrangement & Assembly Drawing
Standard Materials
Overall Dimensions
Discharge Capacities
Instructions for Installation
1
2
3
4
5
6
5/01
5/02, 5/03
5/04,
5/01
5/05
Refer to 2/13, 2/14 & 2/16
VALVE TYPE FL 539 SERIES
5
8/01 to 8/06
APPROVALS
89/01 to 9/02
CAPACITY TESTING FACILITY
910/01 to 10/04
LESER AT A GLANCE
10
-
General Information
PRODUCT RANGE
FAINGER LESER Valves are Spring Loaded, Full Nozzle type, inlet size 15 mm to 200 mm, set pressures from 0.15 bar g to
440 bar g and are available in ANSI 150, 300, 600 class flanges as standard.
O O
FAINGER LESER Valves are suitable for operating temperature from -200 C to 530 C.
FAINGER LESER Valves are available in various materials like Cast Steel to A 216 Gr. WCB, Stainless Steel to A 351 CF 8,
CF 8M, CF 3M, Alloy Steel to A 217 WC6, A 352 LCB, Alloy 20, Monel, Hastelloy 'C' etc.
FAINGER LESER Valves are provided with Trim materials like Stainless Steel AISI 316, 304 L, 321, 316 L, 316 Ti, Monel,
Hastelloy 'C' etc. & Springs of CS to DIN 1.1200, Alloy Steel to DIN 1.8159/1.7102, SS to DIN 1.4310 etc. Springs are
selected according to application.
FAINGER LESER Valves generally meet the requirements of the applicable International standards like ASME Section VIII
Div. 1/API RP 520, DIN 3320, TRD 421, AD-Merkblatt 2000-A2, ISO 4126, IBR 1950 etc.
Great care is needed in the sizing and selection of Safety Valves. The variation in capacity between ISO 4126, ASME
Section VIII and AD-Merkblatt 2000-A2 calculations can be up to 3% max. Special valves can be manufactured
independently from the applied code, as per customer requirement. We are at your service for this task. For any further
information, please contact us.
FAINGER LESER Valves are type test approved by TUV, Germany, Indian Boiler Regulations (IBR), Chief Controller of
Explosives (CCoE), Fluid Control Research Institute (FCRI) etc.
FAINGER LESER Valves are available with following ACCESSORIES to suit the customer specifications and the service
conditions:
Stainless Steel Balanced Bellows for varying back pressure or back pressure higher than 15% of set pressure.
Heating jacket for Viscous Fluids.
Soft 'O' ring seating for tight shut off.
Lift stopper for achieving specified capacity.
Test Gag, Packed Lever Cap.
Cooling Spacer.
l
l
l
l
l
l
Safety Valves protect plants of all kinds from impermissible overpressure. They prevent damage to persons, the
environment and investments. As the last link in the safety chain, their perfect function must be ensured. The requirements
for development, design, production and quality management are correspondingly high.
Only comprehensive tests and trials can ensure that Safety Valves will always function perfectly, even under extreme service
conditions. Since the inception, FAINGER LESER has been operating micro processor based test lab. for determining the
function and characteristics of Valves. Critical components are machined on CNCs to accomplish the demanding
requirements placed by the International standards like DIN 3320, ISO 4126, ASME Sec. VIII etc.
FAINGER LESER VALVES (P.) LTD., a 100% owned subsidiary of M/s. LESER GmbH & Co. KG, Germany, manufactures
Safety & Relief Valves as per M/s. LESER Global Standard. They are approved by various International Agencies like TUV,
ASME etc. The Valves produced by FAINGER LESER are periodically retested at LESER & ASME certified test laboratory in
Germany.
..
..
Gen. Info.
1
1/01FAINGER LESER 2011
-
It has been always our endeavour to supply Safety & Relief Valves with the advanced manufacturing & testing techniques.
In this regard, we take pleasure to state that we are an ISO 9001:2000 certified company and also approved by both
statutory inspection agencies such as IBR, CCoE etc. and various Third Party inspection agencies.
We have manufactured & supplied so far over the past 16 years in excess of 50,000 Safety & Relief Valves to various user
industries for different applications in India & abroad.
CNC machines are also employed in the machine shop to ensure precision & accuracy required for the manufacture of
Safety & Relief Valves of the highest quality.
The microprocessor operated flow characteristic testing facility is used where required to ensure valve operating
performance & relieving capacity with air as the test medium.
The main ADVANTAGES of FAINGER LESER Valves are:
Universal, without changing trim applicable for steam/gas or liquid service, simple and user friendly in
construction.
No hassles of adjusting complicated Blowdown rings, because of fixed Blowdown type.
Blowdown, in general not exceeding the limits of valves with adjusting ring(s).
Higher capacity possible per size; for smaller API/ASME capacities lift stopper is used.
Spring loaded valve as a standard for pressures as low as 0.15 bar g.
Valve capacity & performance test, in-house by computer controlled test facility within its range.
l
l
l
l
l
l
Gen. Info.
1General Information
1/02
Pressure level relation according to ASME Sec. VIII
100
80
60
40
20
0
82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 121
Vessel
Pressure
[%]
Max. proportional
lift range
Lift
[%]
Max. blowdown Max. overpressure
Relieving
Pressure
Popping
Pressure
Set
Pressure
Reseating
Pressure
Pressure vessel requirement vs. typical characteristic of safety valve
Operating
Pressure
Maximum
Allowable
Working
Pressure
Maximum
Allowable
Accumulation
Pressure
single valve
Maximum
Allowable
Accumulation
Pressure
fire case
FAINGER LESER 2011
-
Type FL 441 Standard Pressure
Series for Steam, Gas or Liquid
Service
Full Nozzle, Full Lift Safety Valve
Flanged connections meeting API
requirements.
Size: 25mm (Inlet) to 200mm (Inlet)
Pressure Range: 0.15 bar g to 40.0
bar g (max.) (32.0 bar g max. for
steam service)
IBR approved (C=38)
CCoE approved
l
l
l
l
l
l
Type FL 441 High Pressure
Series for Steam, Gas or
Liquid Service
Full Nozzle, Full Lift Safety Valve
Flanged connections
Size: 25mm (Inlet) to 100mm
(Inlet)
Pressure Range : Maximum upto
400 bar g
(for pressure beyond FL 441 std.
pr. Series)
IBR approved (C=38)
CCoE approved
l
l
l
l
l
l
Type FL 549 Series Safety Relief Valve for Gas,
Liquid or Jacket Heating Steam Service. Also for
Thermal Relief Application
Modified Nozzle Safety Relief Valve
Screwed as well as flanged connections
Size: 15mm (Inlet) to 40mm (Inlet)
Pressure Range: 0.5 bar g to 250 bar g
Special construction possible for further higher Pressure
CCoE approved
l
l
l
l
l
l
Type FL 539 Series for Gas or Liquid
Service
Modified Nozzle Safety Relief Valve
Screwed connections
Compact design with light weight construction
Size: 15mm (Inlet)
Pressure Range: 0.5 bar g to 150 bar g
l
l
l
l
l
Type FL 459 Series for
Steam, Gas or
Liquid Service
Modified Nozzle Safety Relief
Valve
Screwed connections
Size: 20mm & 25mm (Inlet)
Pressure Range: Max upto 440
bar g (for pressure beyond FL
549 series)
IBR approved
l
l
l
l
l
1/03
Selection of Valve Types
Gen. Info.
1
FAINGER LESER 2011
-
CONSTRUCTION TYPE
B - BELLOWS
C - CONVENTIONAL
O - OTHER, TO SPECIFY
SPRING MATERIAL
0 - OTHER, TO SPECIFY
1 - CS CD. PLATED
2 - HIGH TEMP. ALLOY
4 - STAINLESS STEEL
STANDARD ACCESSORIES
0 - OTHER, TO SPECIFY
2 - CLOSED, SCREWED CAP
4 - PACKED LEVER CAP
ORIFICE LETTER
ACC. TO API 526
H C C6 1 2 2 4 X3
74 C S6 4 A A 2
D, E
F
G
H
J
K, L
M, N, P
Q
R
T
FLOW DIA 'do'
ACC. TO TUV
18
23
29
37
46
60
74
92
98
125
165
C6 - CS, ASTM A 216 WCB
(SS 316 TRIM)
SL - SS, ASTM A 351 CF 3
(SS 316 L TRIM)
S5 - SS, ASTM A 351 CF 8
(SS 316 TRIM)
S6 - SS, ASTM A 351 CF 8M
(SS 316 TRIM)
CH - CS, ASTM A 216 WCB
(HASTELLOY C TRIM)
SH - SS, ASTM A 351 CF 8M
(HASTELLOY C TRIM)
6L - SS, ASTM A 351 CF 3M
(SS 316 L TRIM)
HS - ASTM A 217 GR. WC6
(SS 316 TRIM)
LS - ASTM A 352 GR. LCB
(SS 316 TRIM)
AY - ALLOY - 20
(ALLOY - 20 TRIM)
HY - HASTELLOY - 'C'
(HASTELLOY - 'C' TRIM)
SP - SPECIAL
C8 - CS, ASTM A 216 WCB
(SS 316 L TRIM)
00 -
0 - OTHER, TO SPECIFY
1 - OPEN BONNET
2 - JACKETED TYPE
3 - TEST GAG
4 - 'O' RING DISC
6 - STELLITED NOZZLE & DISC
7 - COOLING SPACER
8 - DRAIN PLUG
SPECIAL FEATURES/EXTRA ACCESSORIES
'X' FOLLOWED BY THE FOLLOWING NOS.MATERIAL TYPE
CONNECTION RATING FOR
INLET & OUTLET
A - ANSI 150 #
B - ANSI 300 #
C - ANSI 600 #
0 - OTHER, TO SPECIFY
1 - PN 10
2 - PN 16
3 - PN 25
4 - PN 40
5 - PN 64
MODEL NO.
H/CC61224X3
74/CS64AA2
Prefix B is used in the 1st block along with orifice letter/flow dia for IBR (Indian Boiler Regulations) approved valves.
Other special material also available. Please check specific quotation for model number
PROCEDURE FOR VALVE SIZING & SELECTION
Method of Model Numbering
For Valve Type FL 441 SP Series
2/01
First refer to Type FL 441, Standard Pressure Series. If the range is insufficient, refer to Type FL 441, High Presure Series...
Valves manufactured by FAINGER LESER based on DIN design are type tested & approved by the International Agency, TUV (the
German Type Test approving Authority) and the local statutory bodies like the CCoE (Chief Controller of Explosives), the IBR
(Indian Boiler Regulations Act, 1950) etc.
Sizing calculations are according to ASME Sec. VIII Div. 1 / API RP 520 or DIN 3320 / TRD 421, AD-Merkblatt 2000 - A2, ISO
4126, IBR 1950, where applicable. For IBR Valves of FAINGER LESER, the assigned value of constant is: C=38. Relieving
capacity of the selected Valve would meet the customer required capacity.
Flange rating and center to face dimensions are according to API 526 / DIN 3320. Valves with special connections and
different center to face dimensions can also be provided on request.
FAINGER LESER Valves are tested for seat leakage according to API 527.
NOTE
API
TUV
2
FL 441
SP Series
FAINGER LESER 2011
-
22/02
Safety Valve with Closed Cap, H2
H~
5918
B
1
5
8
7
9
14
12
16
61
C
60
Y
57
56
55
86
19
85
42
75
54
60
FL 441
SP Series
FAINGER LESER 2011
-
42 Cap H2
Lever Cover H4
Lever H4
Lifting Fork
Shaft
Spacer
O-ring
Support Ring/Gland
Washer
Hex. Nut
Circlip
41
43
44
45
75
79
80
81
82
83
Part Name
Body
Seat/Nozzle
Disc
Guide
Bonnet
Spindle
Split Ring
Spring Plate
Adjusting Screw
Lock Nut
Spindle Cap
Name Plate
Spring
Stud
Hex. Nut
Roll Pin
Securing Ring
Gasket
Ball
Pin
Lead Seal
Seal Wire
Securing Ring
1
5
7
8
9
12
14
16
18
19
46
50
54
55
56
57
59
60
61
74
85
86
91
Item
Cap H2, Gastight
Lifting Device H4, Gastight
Assembly of Flanged Spring Loaded Safety Valve
2/03
46
91
74
16
12
54
59
5714
61
7
H2
42
H4
8281
8380
4579 41
44
75
18
19
86
85
56
9
8
60
55
1
2
FL 441
SP Series
5
FAINGER LESER 2011
-
STANDARD MATERIAL (Also Refer to Method of Model Numbering for Details)
C61 S54/S64 SPECIAL-1 SPECIAL-2 SPECIAL-3PART NAMETYPE
PART
No.
C
L
O
S
E
D
C
A
P,
H 2
PAC
KED
LE
VER
, H
4
1
5
7
8
9
12
14
16
18
19
42
54
55
56
57
59
60
61
75
85
86
43
44
45
46
74
80
82
BODY
NOZZLE
DISC ASSEMBLY
SPINDLE GUIDE/
GUIDE INSERT
BONNET
SPINDLE
SPLIT RING
SPRING PLATE
ADJUSTING SCREW
LOCK NUT
CAP (41)
SPRING
STUD
HEX. NUT
ROLL PIN
SECURING RING
GASKET
BALL
SPACER
LEAD SEAL
SEAL WIRE
LEVER
LIFTING FORK
LEVER SHAFT
SPINDLE CAP
PIN
GLAND
HEX. NUT
A 216 Gr. WCB
AISI 316
AISI 316
A 216 Gr. WCB
AISI 316
A 216 Gr. WCB
AISI 316
AISI 316
CS CD. PLATED
AISI 316
AISI 316
A 216 Gr. WCB
CS CD. PLATED/
ALLOY STEEL
A 193 Gr. B7
A 194 Gr. 2H
SS
SS
C.A.F./Non Asb.
SS
C.A.F./Non Asb.
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
CS
CS
A 351 CF 8/8M
AISI 316
AISI 316
A 351 CF 8/8M
AISI 316
A 351 CF 8/8M
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
A 351 CF 8/8M
SS/
ALLOY STEEL
A 193 B8/B8M
A 194 Gr. 8/8M
SS
SS
C.A.F./Non Asb.
SS
C.A.F./Non Asb.
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
AISI 316
SS
A 217 Gr. WC6
AISI 316
AISI 316
A 216 Gr. WCB
AISI 316
A 217 Gr. WC6
AISI 316
AISI 316
CS CD. PLATED
AISI 316
AISI 316
A 216 Gr. WCB
ALLOY STEEL
A 193 Gr. B7
A 194 Gr. 2H
SS
SS
C.A.F./Non Asb.
SS
C.A.F./Non Asb.
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
C.S.
C.S.
A 352 Gr. LCB
AISI 316
AISI 316
A 351 Gr. CF 8M
AISI 316
A 352 Gr. LCB
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
A 351 Gr. CF 8M
SS
A 193 Gr. B7
A 194 Gr. 2H
SS
SS
C.A.F./Non Asb.
SS
C.A.F./Non Asb.
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
AISI 316
SS
A 351 Gr. CF 8/8M
Hastelloy-C
Hastelloy-C
A 351 Gr. CF 8/8M
AISI 316
A 351 Gr. CF 8/8M
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
A 351 Gr. CF 8/8M
SS
A 193 Gr. B8/B8M
A 194 Gr. 8/8M
SS
SS
Non Asb./PTFE
SS
Non Asb./PTFE
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
AISI 316
SS
Standard Materials for Valve Type FL 441
(Standard Pressure Series)
2/04
Material of construction will vary according to the service conditions and customer requirement. Other special materials,
for example, Monel, Alloy-20, CF 3, CF 3M and accessories such as Balanced Bellows, Cooling Spacer, Test Gag, Heating Jacket,
Drain Plug, Soft Seat (O-Ring) Disc etc. can be provided on request.
NOTE
Note: The above material is for standard construction. Suitable material to be used for corrosion resistant/special application.
-60
-76
-10
14
200
392
300
572
540
1000
DIN 1.4310 (SS)
DIN 1.8159 (ALLOY STEEL)
DIN 1.1200 (CS)
-268
-268
-450
-450
-102
-151
-29
-21
427
800
540
10000
F
0
F
0
C
0
C
ASTM A 351 CF 8/8M
ASTM A 352 LCB ASTM A 216 WCB
ASTM A 217 WC6
TEMPERATURE Vs. MATERIAL OF CONSTRUCTION
SPRING
BODY
Standard Materials2
FL 441
SP Series
FAINGER LESER 2011
-
12
3
4
5
6
7
8
9
10
11
12
13
Sl.
No.
Inlet
Size
inches
Outlet
Size
inches
Max.
Set Pr.
bar g
Letter Area
sq. in.
Orifice Details
Area
sq. mm
Dia, "d"
mm
Weight
Approx.
kgs.
Height H Approx. Center to face
1
1
1
1
1
2
2
3
3
3
4
4
4
4
6
6
8
2
2
2
3
3
3
3
4
4
4
6
6
6
6
8
10
10/12
40.0
40.0
40.0
40.0
20.0
40.0
20.0
40.0
40.0
20.0
40.0
40.0
40.0
40.0
40.0
25.0
20.0
D
E
F
G
H
H
J
J
K
L
L
M
N
P
Q
R
T
0.110
0.196
0.307
0.503
0.785
0.785
1.287
1.287
1.838
2.853
2.853
3.600
4.340
6.380
11.050
16.000
26.000
71.0
126.5
198.1
324.5
506.5
506.5
830.3
830.3
1185.8
1840.6
1840.6
2322.6
2800.0
4116.1
7129.0
10322.6
16774
9.50
12.70
15.88
20.33
25.40
25.40
32.51
32.51
38.86
48.41
48.41
54.38
59.70
72.40
95.30
114.60
141.72
12.0
12.0
14.0
16.0
20.0
22.0
24.0
30.0
38.0
48.0
52.0
56.0
75.0
98.0
140.0
165.0
185.0
340
340
360
360
440
445
490
490
550
645
665
665
760
800
860
985
1020
340
340
360
360
460
465
510
510
575
695
715
715
810
855
910
985
1020
114
114
121
121
124
124
124
143
162
165
184
184
210
229
241
267
279
105
105
124
124
130
137
137
137
156
156
178
178
197
181
240
240
276
11.0
11.0
11.0
11.0
11.0
11.0
11.0
13.0
14.0
16.0
16.0
16.0
18.0
18.0
20.0
20.0
20.0
1. Flange ratings and center to face dimensions are according to API RP 526 as applicable for Full Nozzle Safety
Valves of inlet size 1" (25mm) and above.
2. For revised sizes due to higher pressure & Temp., refer to page # 7/06.
3. For smaller sizes, refer to FL 539 & FL 549 series.
Overall Dimensions
Closed
Cap, H2
mm
Packed
Lever, H4
mm
Outlet
"B"
mm
Inlet
"C"
mm
"Y"
mm
2/05
NOTE
2
FL 441
SP Series
FAINGER LESER 2011
-
2FL 441
SP Series
2/06
Discharge Capacities
SET PRESSURE, psigOrificeMedium
Letter 15 30 50 75 100 125 150 200 250 300 350 400 450 500 550 575
D Steam 172 263 385 537 689 841 993 1296 1600 1904 2208 2511 2815 3119 3423 3575
Air 65 94 137 192 246 300 354 463 571 680 788 897 1005 1114 1222 1276
Water 11 15 19 24 27 30 33 38 43 47 51 54 58 61 64 65
E Steam 307 469 686 957 1227 1498 1769 2310 2851 3392 3934 4475 5016 5558 6099 6370
Air 115 168 245 342 438 535 632 825 1018 1211 1405 1598 1791 1985 2178 2274
Water 19 27 34 42 48 54 59 69 77 84 91 97 103 108 114 116
F Steam 481 735 1074 1498 1922 2346 2770 3618 4466 5314 6161 7009 7857 8705 9553 9977
Air 180 263 384 535 686 838 989 1292 1595 1897 2200 2503 2806 3108 3411 3563
Water 29 42 54 66 76 85 93 107 120 132 142 152 161 170 178 182
G Steam 788 1205 1760 2455 3150 3844 4539 5928 7317 8706 10095 11484 12873 14263 15652 16346
Air 295 430 629 877 1125 1373 1621 2117 2613 3109 3605 4101 4597 5093 5589 5837
Water 48 68 88 108 124 139 152 176 197 215 233 249 264 278 292 298
H Steam 1230 1880 2747 3831 4915 5999 7083 9251 11419 13587 15755 17923 20091 22259 24427 25511
Air 460 671 981 1368 1755 2142 2529 3303 4078 4852 5626 6400 7174 7948 8722 9109
Water 75 106 137 168 194 217 238 275 307 336 363 388 412 434 455 466
J Steam 2016 3083 4504 6281 8059 9836 11613 15167 18721 22276 25830 29384 32939 36493 40047 41824
Air 754 1101 1608 2243 2878 3512 4147 5416 6685 7954 9223 10493 11762 13031 14300 14935
Water 123 174 225 276 318 356 390 450 503 551 595 637 675 712 746 763
K Steam 2879 4402 6433 8971 11509 14047 16585 21661 26737 31813 36889 41965 47041 52116 57192 59730
Air 1077 1572 2297 3203 4110 5016 5922 7735 9547 11360 13172 14985 16797 18610 20422 21329
Water 176 249 321 394 455 508 557 643 719 787 850 909 964 1016 1066 1090
L Steam 4470 6833 9985 13925 17864 21804 25743 33622 41501 49380 57260 65139 73018 80897 88776 92715
Air 1672 2440 3565 4972 6379 7786 9192 12006 14819 17633 20446 23260 26073 28887 31700 33107
Water 273 386 499 611 706 789 864 998 1116 1222 1320 1411 1497 1578 1655 1692
M Steam 5640 8622 12599 17570 22541 27512 32483 42426 52368 62310 72252 82194 92136 102078 112020 116991
Air 2109 3079 4499 6274 8049 9824 11599 15149 18700 22250 25800 29350 32900 36450 40000 41775
Water 345 488 630 771 890 995 1090 1259 1408 1542 1666 1781 1889 1991 2088 2135
N Steam 6799 10395 15189 21182 27175 33168 39161 51146 63132 75118 87104 99089 111075 123061 135046 141039
Air 2543 3712 5424 7564 9704 11844 13984 18263 22543 26823 31103 35383 39663 43943 48223 50363
Water 416 588 759 930 1073 1200 1315 1518 1697 1859 2008 2147 2277 2400 2517 2574
P Steam 9995 15281 22329 31139 39948 48758 57568 75187 92807 110427 128046 145666 163285 180905 198524 207334
Air 3738 5457 7973 11119 14265 17411 20556 26848 33140 39431 45723 52015 58306 64598 70890 74035
Water 611 864 1116 1366 1578 1764 1932 2231 2495 2733 2952 3156 3347 3528 3700 3784
Q Steam 17311 26466 38673 53931 69190 84448 99706 130223 160740 191256 221773
Air 6475 9451 13809 19258 24706 30155 35603 46500 57397 68294 79191
Water 1058 1497 1932 2367 2733 3055 3347 3865 4321 4733 5113
R Steam 25066 38322 55997 78090 100184 122277 144371 188558 232745 276932 321119
Air 9375 13684 19996 27885 35774 43663 51552 67331 83109 98888 114666
Water 1533 2167 2798 3427 3957 4424 4846 5596 6256 6854 7403
T Steam 40732 62274 90995 126897 162799 198701 234603 306407 378211 450014
Air 15234 22237 32493 45313 58133 70953 83773 109412 135052 160692
Water 2490 3522 4547 5569 6430 7189 7875 9093 10167 11137
Calculation of mass flow acc. to ASME Sec. VIII Div. 1/ API 526
Capacities shown here are indicative. For detailed calculations, please provide the complete process data.
NOTE
Saturated Steam capacity in lb/h Air capacity at 15C in scfm Water capacity in U.S.gpm
FAINGER LESER 2011
-
Discharge Capacities
2/07
Calculation of mass flow acc. to DIN 3320 TRD 421, AD-Merkblatt 2000-A2, ISO 4126
NOTE
Capacities shown here are indicative. For detailed calculations, please provide the complete process data.
Saturated Steam capacity in kg/h 3Air capacity at 15C in Nm /h Water capacity in /h3m
SET PRESSURE, bar g FlowMedium
dia mm 0.30 0.75 1.5 3.5 5.5 7.5 11.0 13.0 15.0 19.0 23.0 27.0 32.0 39.0
18 Steam 105 164 254 442 626 806 1118 1293 1468 1812 2155 2491 2910
Air 118 191 304 547 790 1033 1458 1701 1944 2430 2916 3402 4010 4860
Water 3 5 7 11 14 16 19 21 23 25 28 30 33 36
23 Steam 171 268 415 721 1022 1316 1825 2111 2397 2959 3518 4068 4752
Air 193 312 496 893 1289 1686 2381 2777 3174 3968 4761 5555 6546 7935
Water 5 8 12 18 22 26 32 34 37 41 46 49 54 59
29 Steam 273 426 660 1146 1624 2092 2902 3356 3811 4705 5594 6467 7554
Air 307 497 788 1419 2050 2681 3785 4415 5046 6308 7569 8831 10407 12615
Water 8 13 19 28 35 41 50 55 59 66 73 79 86 95
37 Steam 444 694 1074 1866 2644 3406 4724 5463 6204 7658 9105 10527 12297
Air 501 809 1283 2310 3337 4364 6161 7187 8214 10268 12321 14375 16941 20535
Water 13 21 30 46 58 67 82 89 95 107 118 128 139 154
46 Steam 686 1072 1659 2884 4087 5265 7301 8445 9589 11837 14074 16271 19007
Air 774 1250 1984 3571 5158 6745 9522 11109 12696 15870 19044 22218 26186 31740
Water 21 33 47 71 89 104 126 137 147 166 183 198 215 238
60 Steam 1167 2027 2823 4906 6953 8957 12422 14367 16314 20138 23944 27682 32336
Air 1316 2363 3375 6075 8775 11475 16200 18900 21600 27000 32400 37800 44550 54000
Water 35 56 79 121 152 177 215 234 251 282 311 337 367 405
74 Steam 1775 3083 4294 7463 10576 13625 18895 21854 24816 30632 36421 42108 49187
Air 2002 3594 5134 9241 13348 17455 24642 28749 32856 41070 49284 57498 67766 82140
Water 54 85 121 184 231 270 327 355 382 430 473 512 557 615
92 Steam 2743 4766 6638 11535 16347 21059 29205 33778 38357 47347 56294 65084 76027
Air 3095 5555 7935 14283 20631 26979 38088 44436 50784 63480 76176 88872 104742
Water 83 132 187 285 357 417 505 549 590 664 731 792 862
98 Steam 3112 5408 7532 13088 18548 23895 33139 38328 43523 53724 63877
Air 3511 6303 9004 16207 23410 30613 43218 50421 57624 72030 86436
Water 95 150 212 323 405 473 573 623 669 753 829
125 Steam 5064 8798 12253 21293 30177 38876 53914 62357 70809 87405 103923
Air 5713 10254 14648 26367 38086 49805 70313 82031 93750 117188 140625
Water 154 244 344 526 659 770 933 1014 1089 1226 1349
165 Steam 8823 15329 21350 37102 52580 67737 93940 108650 123378 152295
Air 9954 17866 25523 45942 66361 86780 122513 142931 163350 204188
Water 268 424 600 917 1149 1342 1625 1767 1898 2136
2
FL 441
SP Series
FAINGER LESER 2011
-
2FL 441
SP Series
SET PRESSURE, bar g Flow
dia mm 1 2 4 6 8 10 12 14 16 18 20 24 28 32
18 195 291 485 678 872 1065 1259 1452 1646 1839 2033 2420 2807 3194
23 318 476 792 1108 1424 1739 2055 2371 2687 3003 3319 3951 4582 5214
29 505 757 1259 1761 2263 2765 3268 3770 4272 4774 5276 6281 7285 8289
37 823 1232 2049 2867 3684 4501 5319 6136 6954 7771 8589 10224 11859 13494
46 1272 1904 3167 4431 5694 6958 8221 9485 10748 12012 13275 15803 18330 20857
60 2164 3239 5388 7538 9688 11837 13987 16137 18286 20436 22586 26885 31185 35484
74 3291 4926 8196 11466 14736 18006 21276 24546 27816 31086 34356 40895 47435 53975
92 5087 7614 12668 17723 22777 27831 32885 37939 42993 48048 53102 63210 73319 83427
98 5772 8640 14375 20110 25844 31579 37314 43049 48784 54519 60254 71724 83194
125 9391 14056 23386 32717 42047 51377 60708 70038 79368 88699 98029 116690
165 16363 24491 40749 57006 73263 89520 105777 122034 138291154548 170806
2/08
Discharge Capacities
Calculation of mass flow acc. to IBR 1950
Capacities shown here are indicative. For detailed calculations, please provide the complete process data.
NOTE
(Saturated Steam capacity in kg/h)
FAINGER LESER 2011
-
1. Safety Valves with Stainless Steel Bellows
There are two reasons for the use of stainless steel bellows:
a) Bellows reliably seal the bonnet to the outlet chamber, protecting the guides, moving parts and the spring against
failure through action of the fluid, such as dirt, corrosion, impurities or temperature.
b) Stainless-steel bellows compensate for the effects of back pressure. They are so designed that the effective area of the
bellows is equivalent to that of the seating area.
Stainless-steel bellows must be used when built-up back pressure exceeds 15% of set pressure. Stainless steel bellows
can be used for back pressure up to a maximum of 35% of the set pressure.
The stainless-steel balanced bellows inherent stiffness affects set and function performance. The min. set pressure is
also dependent on the nominal dia. (DN) chosen. Depending on the set pressure, either single or double-walled
stainless steel bellows (standard) are used. A shield may also have to be installed if the unit is subjected to a
particularly high level of stress, such as abrasive fluids, flow effects, etc.
A BSP/NPT control thread is fitted into the bonnet to
monitor the efficiency of the bellows. A discharge pipe can
be attached to the threaded drain, in the event that
provisions have to be made for a safe discharge of fluids in
special cases e.g. aggressive or toxic fluids.
The design height of the safety valve is altered if the
stainless steel bellows are installed.
Material & Limits of Application
Bellow material : SS 316 L
O
Temperature limits : Up to 450 C
Set pressure : 3.0 bar min.
Back pressure : Max. 35% of set pressure
Accessories
2/09
FL 441
2
Special materials and lower set pressures are also possible. Please check availability.
NOTE
FAINGER LESER 2011
-
2. Safety Valves with Heating Jacket
Safety Valve can be fitted with a heating jacket for special applications. Areas of application are systems to be protected from
media, which are viscous, sticky or have tendency to crystallize out of solution.
In case of flanged Safety Valves without stainless steel bellows, only the bodies are fitted with a heating jacket. The heating
connections for these Safety Valves shall be NPT female or ANSI 150 # RF.
Safety Valves with stainless steel bellows
For Safety Valves with stainless steel bellows, the bonnet spacer required to house the bellows is fitted with an additional
heating jacket. Both heating jackets are joined by a threaded pipe bend.
To protect the sliding parts and the spring against inadmissible influence of temperature an additional equipment will beo o
necessary for all flanged spring loaded valves if the fluid temperature is 400 C (752 F) and higher.
o o
If the temperature is higher than 450 C (842 F) stainless steel bellows should be provided as far as they are not fitted
already by reason of the back pressure ratio.
Accessories
o
3. Safety Valves with Cooling Spacer for higher temperature (above 400 C)
2/10
FL 441
2
54
55
56
11
15
1
7
5
FAINGER LESER 2011
-
Accessories
2/11
4. Safety Valves with Test Gag
5. Safety Valves with Lift Stopper
In order to allow the adjustment of each Safety Valve in a plant provided with several Safety Valves or to carry out a pressure test
above the allowable operating pressure a test gag is required. The test gag is fitted in the lever cover and exerts force on top of
the spindle. After testing the test gag shall be removed.
That Safety Valves are only available in standardized nominal diameters, the valve could in a given application be oversized. It
is therefore recommended to reduce the lift by means of a lift stopper, thus reducing the coefficient of discharge in addition.
Lift stoppers must allow a lift of at least 1 mm.
FL 441
2
Lift limitation by bush Lift limitation by gag
FAINGER LESER 2011
-
Instructions for the Treatment and Installation of
Pressure Relief Valves.
1. General Notes
Pressure Relief Valves are highly quality instruments which should
be handled with great care. To ensure the correct performance of
a pressure relief valve all parts are made with exact precision.
Only this precision ensures the correct functioning of the pressure
relief valves. Careless handling of the finished valve in
workshops, stores, during transportation or installation could
cause leakage or possibly permanent damage (also refer to API
Report Guide for inspection of refinery equipment, Chapt. XVI
Pressure Relieving Devices" Para 1603082 and 1603083).
The sealing surfaces have been ground and lapped with high
precision to ensure the required tightness. Even though the
surfaces are extremely hard, the seal can still be damaged. By all
means, one must take care to prevent impurities from entering
the valve during transportation, installation and operation.
When installing pressure relief valves with threaded connections,
use only metal seal washers. Seal materials such as hemp or
PTFE tape should not be used as this type of material can break
off and enter the valve causing it to leak.
If valves with open bonnets and/or levers are to be painted after
despatch from the factory, care must be taken to protect the
sliding parts. Otherwise the correct operation of the pressure
relief valve may be affected.
2. Transport Protection
The inlet and outlet of the pressure relief safety valves are
protected during transportation with plastic caps. These caps
should only be removed just before installing the valve.
The lifting lever of spring loaded pressure relief valves is secured
with a wire to the bonnet. This wire should be removed only after
installation. For testing the set pressure or tightness of the
pressure relief valve remove also this wire and take care that the
lever is not engaged with the spindle cap.
3. Installation/Assembly
3.1 General Notes
Spring loaded pressure relief valves should be installed
with the bonnet VERTICALLY UPWARDS.
Furthermore, pressure relief valves should be mounted
in such a way that no inadmissible static, dynamic or
thermal loads can be transmitted to the valve due to up
and downstream pipe work. If necessary, expansion
possibilities should be provided. Stresses by incorrect
mounting should be avoided.
3.2 Draining of Condensate
To prevent dirt and all kinds of impurities from the
pressure relief valve the drainage of discharge pipe and
pressure relief valve must be done via discharge pipe.
Therefore, FAINGER LESER pressure relief valves are not
normally provided with drain holes.
According to rules a drain hole of sufficient size must be
incorporated at the lowest point of pipe work. In all
cases the discharge pipe must first slope in a
downwards direction and fitted with a suitable size
drain hole before any bends are connected (refer to
sketch).
Exception:
In special cases, for instance on board of ships an optional
drain hole may be recommended in the valve body as it may
be that pipe work drainage cannot be guaranteed at a lower
point than the valve. The standard drain hole which will then
be supplied by the factory is 1/4" BSP. But, by all means, the
discharge pipe must be drained too. In extreme cases this
hole can be drilled outside of our factory provided that
special care is taken to ensure that no damage is done to the
sealing surfaces.
All drainage pipes that have been connected must be free of
restriction and the ends easily seen. Care must be taken
when discharging any drainage to prevent injury to
personnel. For example on steam connect a suitable steam
trap.
Note!
When valves are supplied with a drain hole that is not going
to be used the plastic plug fitted in the hole must be removed
and replaced by a metal plug.
3.3 Mounting Brackets
For pressure relief valves with mounting brackets a
fastening possibility for the brackets should be provided
to withstand the forces of reaction when valve blows off.
The bracket holes can be drilled on request.
3.4 Insulation
In case any insulation of the pressure relief valve is
provided, the bonnet must be kept free to avoid
unacceptable heating up of the spring.
3.5 Inlet Pipe
The inlet pipe for pressure relief valves should be as
short as possible and should be so arranged, that when
the valve is in its fully open position the pressure drop
must not exceed 3% of set pressure, the edging at the
inlet pipe should be rounded off or at least be
chamfered.
If the calculation results in a higher than 3% pressure
drop of set pressure then the inlet pipe size must be
enlarged.
3.6 Discharge Pipes/Back Pressure
The discharge piping on vapours and gases should be
installed in an ascending direction, on liquids in an
inclined direction.
2/13
FL 441
2
FAINGER LESER 2011
-
The discharge pipework of all pressure relief valves
should be so arranged that the back pressure, which is
built up during blow off, does not exceed a max. 15% of
set pressure.
In case of higher back pressure, pressure relief valves
with pressure compensating metal bellows (balanced
type) shall be used. In case the back pressure is >0.15
times set pressure the capacity of the pressure relief
valves must be recalculated.
3.7 Pressure Relief Valves with bellows
Pressure relief valves with elastomer bellows (TRD 721)
as well as metal bellows have a vent hole in the bonnet.
When fitting pressure relief valve with a vent hole care
must be taken to prevent moisture from entering the
bonnet. However, fluid escaping from the vent hole
indicates that the bellows have failed. Repair is
required.
When pressure relief valves with bellows are used with
toxic or inflammable fluids, care must be taken to fit a
suitable vent pipe to provide safe venting. For this
purpose, the vent can be threaded 1/4" BSP female on
request.
4. Mode of Operation/Maintenance
The working pressure of the plant should be at least 5% below the
blow down pressure of the valve to enable a correct reseat. When
a slight leakage occurs, due to deposits between the sealing
surfaces, surfaces can be cleaned by operating the lifting lever
causing the valve to blow off.
The valve should be closed by sudden release of the lever. If this
procedure does not stop the leakage, the valve seals are
probably damaged. Repairs should be carried out at our
workshop or by a qualified person.
It is recommended and in Germany required by Rules to lift
manually the valve lifting lever from time to time in order to
prevent accumulation of deposits that will affect valve operation.
For steam generators, the following requirements are
established in the German Technical Rules for Steam Boilers TRD
601, edition 6.83, Section 6.
"Testing of pressure relief valves is required for plants operating
with demineralized water and for hot water generators at
intervals of at least 6 months, with the exception of power plants.
For other steam generators, the test interval should not exceed 4
weeks".
It is important to ensure that the lifting lever does not engage the
spindle cap after the lift operation. The lever must be deflected
towards the center line of the bonnet until the lifting fork is
disengaged.
For pressure relief valves with open bonnet, a drain groove is
provided in the guide flange. Whilst blowing, condensate
escaping through the clearance between guide disc and spindle
is drained through this groove.
According to DIN specification 4754, Oct. 74 Edition
"Explanations", Para 4.4 pressure relief valves represent the last
step in the line of protection for the vessel, and they should be
able to prevent excess pressure when all other automatic or pilot
operated checking instruments have failed. To guarantee this
function pressure relief valves require, like all other technical
equipment, regular service. How often a valve must be checked,
depends on the actual operating conditions, so that no general
indications can be given. Usually pressure relief valves operating
in a corrosive atmosphere or on laden fluids require service more
often than valves operating clean conditions. This also applies if
the pressure relief valve operates frequently causing a higher
wear out to the seat and disc.
Special consideration is required if conditions such as vibration
(to be avoided, if possible) pressure pulsation and/or a too small
difference between working and set pressure cannot be avoided.
2/14
Instructions for the Treatment and Installation of
Pressure Relief Valves.
FL 441
2
Add, drain pipe in case of
prepared drain hole
FAINGER LESER 2011
-
1. Loosen the existing lead seal.
2. Press the lever (43) towards the middle until it reaches the
stop so that the lifting fork(44) no longer holds the
spindle cap (46).
3. Loosen and remove the lever cover (41).
4. Loosen the spindle cap (46) from the spindle (12),
remove the securing ring (91) and the pin (74).
5. Loosen the lock nut (19) of the adjusting screw (18).
6. Turn the adjusting screw (18) anticlockwise to remove the
all spring tension.
7. Remove the hex. nuts (56) from the flange of the bonnet
(9).
8. Lift off the bonnet (9).
9. Remove the upper spring plate (16).
10. Lift of the spring (54) and remove lower spring plate (16)
and split rings (14).
11. Remove spindle (12) with guide (8) and disc (7).
12. Carefully clean seat (5) and disc (7), and if required body
internals.
13. Refit spindle (12) with guide (8) and disc (7).
14. Fit the split rings (14) into spindle groove and retain with
the securing ring (59); slip on lower spring plate (16) to
locate on split rings (14).
15. Replace spring (54).
16. Slip on the upper spring plate (16) onto the spindle (12).
17. Align adjusting screw (18), and bonnet (9), over the
spindle (12) and refit.
18. Fit and tighten the hex. nuts (56).
19. Load the spring (54) to obtain the required set pressure.
Clockwise rotation of adjusting screw (18) increases
pressure. Anticlockwise rotation of adjusting screw (18)
reduces pressure.
20. Tighten the lock nut (19) onto the adjusting screw (18).
21. Refit and secure spindle cap (46) by pin (74) and
securing (91).
22. Screw-on the lever cover (41).
23. Pull the lever (43) towards the middle so that the lifting
fork (44) is pushed under the spindle cap (46).
24. Test spindle will lift correctly by pulling lever.
These instructions are applicable for Relief Valves, Safety
Valves and Safety Relief Valves.
2/15
Dismantling and Assembly Instructions
For Valve Type FL 441, FL 459 & FL 549 Series
FL 441
2
44
41
43
18
19
During all work the spindle has to be secured against twisting in order to prevent damage to the sealing surfaces.
CAUTION
FAINGER LESER 2011
-
Remove lead seal.
Remove pin (74).
Pull lever (43) from lever cover.
Unscrew and remove lever cover (41).
Slacken locknut (19).
Turn adjusting screw (18) to the required set pressure.
Draw attention to the admissible pressure range of the spring !
Clockwise turning of adjusting screw increases the spring
tension, obtaining a higher set pressure.
Turning anticlockwise of adjusting screw reduces the spring
tension, obtaining a lower set pressure.
Reassemble in reverse order and lock at the set pressure.
2/16
1. Remove lead seal.
2. Remove pin (74).
3. Pull lever (43) from lever cover (41).
4. Unscrew and remove lever cover (41).
5. Remove Pin (74).
6. Remove spindle cap (46) from spindle (12).
7. Slacken lock nut (19) of adjusting screw (18).
8. Turn adjusting screw (18) anticlockwise to remove all spring
tension.
9. Unscrew bonnet (9), but first loosen discharge pipe.
10. Remove upper spring plate (17).
11. Lift off the spring (54).
12. Withdraw assembly of spindle (12), lower spring plate (16)
and disc (7).
13. Carefully clean seat (1) and disc (7), and if required body
internals.
14. Refit spindle (12) with lower spring plate (16) and disc (7).
Care should be taken to ensure valve spindle is not rotated.
74
19
43
41
18
Lifting Device H4
ATTENTION
15. Replace spring (54).
16. Slip on upper spring plate (17) to the spindle (12).
17. Align adjusting screw (18) and bonnet (9) over spindle (12)
and refit.
18. Load the spring (54) to obtain the required set pressure.
Draw attention to the admissible pressure range of the
spring !
Clockwise rotation of adjusting screw (18) increases
pressure.
Anticlockwise rotation of adjusting screw (18) reduces
pressure.
19. Tighten locknut (19).
20. Refit spindle cap (46) on the spindle (12).
21. Drive in pin (74).
22. Screw on lever cover (41).
23. Refit lever (43).
24. Drive in pin (74).
25. Seal the valve.
Spring Replacement
Dismantling and Assembly Instructions
For Valve Type FL 539 Series
FL 441
2
FAINGER LESER 2011
-
CONSTRUCTION TYPE
B - BELLOWS
C - CONVENTIONAL
O - OTHER, TO SPECIFY
SPRING MATERIAL
0 - OTHER, TO SPECIFY
1 - CS CD. PLATED
2 - HIGH TEMP. ALLOY
4 - STAINLESS STEEL
STANDARD ACCESSORIES
0 - OTHER, TO SPECIFY
2 - CLOSED, SCREWED CAP
4 - PACKED LEVER CAP
ORIFICE LETTER
ACC. TO API 526
*H C C6 1 5 2 4 X3
*74 C S6 4 C A 2
D, E
F
G
H
J
K, L
M, N, P
FLOW DIA 'do'
ACC. TO TUV
12
15
18
23
29
37
46
60
74
C6 - CS, ASTM A 216 WCB
(SS 316 TRIM)
S5 - SS, ASTM A 351 CF 8
(SS 316 TRIM)
S6 - SS, ASTM A 351 CF 8M
(SS 316 TRIM)
4L - SS, ASTM A 351 CF 3
(SS 316 L TRIM)
6L - SS, ASTM A 351 CF 3M
(SS 316 L TRIM)
HS - ASTM A 217 GR. WC6
(SS 316 TRIM)
00 - OTHER, TO SPECIFY
0 - OTHER, TO SPECIFY
1 - OPEN BONNET
2 - JACKETED TYPE
3 - TEST GAG
4 - 'O' RING DISC
6 - STELLITED NOZZLE & DISC
7 - COOLING SPACER
8 - DRAIN PLUG
SPECIAL FEATURES/EXTRA ACCESSORIES
'X' FOLLOWED BY THE FOLLOWING NOS.MATERIAL TYPE
CONNECTION RATING FOR
INLET & OUTLET
A - ANSI 150 # (For outlet only)
B - ANSI 300 #
C- ANSI 600 # (For inlet only)
D- ANSI 900 # II
E - ANSI 1500 # II
F - ANSI 2500 # II
0 - OTHER, TO SPECIFY
3 - PN 25 (For outlet only)
4 - PN 40
5 - PN 64 (For inlet only)
6 - PN 100 II
7 - PN 160 II
MODEL NO.
*H/CC61524X3
*74/CS64CA2
1) Prefix B is used in the 1st block along with orifice letter/flow dia for IBR (Indian Boiler Regulations) approved valves.
2) For Valve Type FL 441, High Pressure Series, Prefix ' * ' is added in the 1st block.
PROCEDURE FOR VALVE SIZING & SELECTION
Method of Model Numbering
For Valve Type FL 441 HP Series
3/01
Valves manufactured by FAINGER LESER based on DIN design are type tested & approved by the International Agency, TUV
(the German Type Test approving Authority) and the local statutory bodies like the CCoE (Chief Controller of Explosives), the
IBR (Indian Boiler Regulations Act, 1950) etc.
Sizing calculations are according to ASME Sec. VIII Div. 1 / API RP 520 or DIN 3320 / TRD 421, AD-Merkblatt 2000 - A2,
ISO 4126, IBR 1950, where applicable. For IBR Valves of FAINGER LESER, the assigned value of constant is: C=38. Relieving
capacity of the selected Valve would meet the customer required capacity.
Flange rating and center to face dimensions are according to API 526 / DIN 3320. Valves with special connections and
different center to face dimensions can also be provided on request.
FAINGER LESER Valves are tested for seat leakage according to API 527.
NOTE
API
TUV
3
FL 441
HP Series
FAINGER LESER 2011
-
3FL 441
HP Series
Safety Valve with Packed Lever Cap, H4
60
57
56
55
59
54
75
69
43
74
46
B
Y
C
H~
14
9
12
18
19
85
86
44
41
45
8
5
7
1
16
61
60
3/02 FAINGER LESER 2011
-
3/03
3
FL 441
HP Series
Note: The above material is for standard construction. Suitable material to be used for corrosion resistant/special application.
-60
-76
-10
14
200
392
300
572
540
1000
DIN 1.4310 (SS)
DIN 1.8159 (ALLOY STEEL)
DIN 1.1200 (CS)
-268
-268
-450
-450
-102
-151
-29
-21
427
800
540
10000
F
0
F
0
C
0
C
ASTM A 351 CF 8/8M
ASTM A 352 LCB ASTM A 216 WCB
ASTM A 217 WC6
TEMPERATURE Vs. MATERIAL OF CONSTRUCTION
Material of construction will vary according to the service conditions and customer requirement. Other special materials,
for example, Monel, Alloy-20, CF 3, CF 3M and accessories such as Cooling Spacer, Test Gag, Heating Jacket, Drain Plug,
Soft Seat (O-Ring) Disc etc. can be provided on request.
STANDARD MATERIAL (Also Refer to Method of Model Numbering for Details)
C41 / C61 S44 / S54 / S64 SPECIAL-1PART NAMETYPE
PART
No.
C
L
O
S
E
D
C
A
P,
H 2
PA
CK
ED
LEVER,
H4
1
5
7
8
9
12
14
16
18
19
42
54
55
56
57
59
60
61
69
75
85
86
43
44
45
46
74
80
82
BODY
NOZZLE
DISC ASSEMBLY
SPINDLE GUIDE/
GUIDE INSERT
BONNET
SPINDLE
SPLIT RING
SPRING PLATE
ADJUSTING SCREW
LOCK NUT
CAP (41)
SPRING
STUD
HEX. NUT
ROLL PIN
SECURING RING
GASKET
BALL
AXIAL THRUST BALL BEARING
SPACER
LEAD SEAL
SEAL WIRE
LEVER
LIFTING FORK
LEVER SHAFT
SPINDLE CAP
PIN
GLAND
HEX. NUT
A 216 Gr. WCB
AISI 316 Stellited
AISI 316 Stellited
A 216 Gr. WCB
AISI 316
A 216 Gr. WCB
AISI 316
AISI 316
CS CD. PLATED
AISI 316
AISI 316
A 216 Gr. WCB
CS CD. PLATED/
ALLOY STEEL
A 193 Gr. B7
A 194 Gr. 2H
SS
SS
C.A.F. / Non Asbestos
SS
C.A.F. / Non Asbestos
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
CS
CS
A 351 Gr. CF 8/8M
AISI 316 Stellited
AISI 316 Stellited
A 351 Gr. CF 8/8M
AISI 316
A 351 Gr. CF 8/8M
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
A 351 Gr. CF 8/8M
SS/
ALLOY STEEL
A 193 Gr. B8 / B8M
A 194 Gr. 8/8M
SS
SS
C.A.F. / Non Asbestos
SS
C.A.F. / Non Asbestos
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
AISI 316
SS
A 217 Gr. WC6
AISI 316 Stellited
AISI 316 Stellited
A 216 Gr. WCB
AISI 316
A 217 Gr. WC6
AISI 316
AISI 316
CS CD. PLATED
AISI 316
AISI 316
A 216 Gr. WCB
ALLOY STEEL
A 193 Gr. B7
A 194 Gr. 2H
SS
SS
C.A.F. / Non Asbestos
SS
C.A.F. / Non Asbestos
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
C.S.
C.S.
NOTE
SPRING
BODY
Standard Materials
FAINGER LESER 2011
-
3/04
Overall Dimensions3
FL 441
HP Series
Special sizes & connections or different center to face dimensions etc. can also be provided on request.
Inlet flange rating shall be from ANSI 600# to ANSI 2500# & the corresponding outlet flange rating shall be ANSI 150#
to ANSI 300# as per customer requirement. However, for inlet flange rating ANSI 1500# & above the outlet flange rating
shall be ANSI 300# in all cases.
*The applicable sizes are for only steam service when set pressure is above 32.0 bar g.
NOTE
143 18
1 25 50 160 15 15.0 450 475 100 135 13.0
250 12
143 18
2 40 50 160 15 18.0 435 460 152 124 13.0
250 12
78 29
3 40 80 130 23 25.0 510 535 120 145 14.0
160 18
73 37
4 50 80 139 29 35.0 565 590 120 170 16.0
160 23
48 46
5 80 100 90 37 50.0 670 720 155 180 16.0
140 29
40* 60*
6 80 150 65 46 80.0 760 810 180 190 17.0
100 37
36* 74*
7 100 150 55 60 105.0 835 885 190 215 17.0
86 46
Sl.
No. Size
mm
Size
mm
Max.
Set Pr.
bar g
Weight
Approx.
kgs.
Height " H Approx. Center to face
Closed
Cap, H2
mm
Packed
Lever, H4
mm
Outlet
"B"
mm
Inlet
"C"
mm
"Y"
mm
Inlet Outlet
Flow
dia
mm
FAINGER LESER 2011
-
3/05
3
FL 441
HP Series
SET PRESSURE, psigOrificeMedium
Letter 575 600 625 675 700 750 775 800 850 850 900 950 1000
D Steam 3575 3727 3879 4182 4334 4638 4790 4942 5246 5246 5549 5853 6157
Air 1276 1331 1385 1493 1548 1656 1710 1765 1873 1873 1982 2090 2199
Water 65 67 68 71 72 75 76 77 79 79 82 84 86
E Steam 6370 6640 6911 7452 7723 8264 8535 8805 9347 9347 9888 10429 10970
Air 2274 2371 2468 2661 2758 2951 3048 3144 3338 3338 3531 3724 3917
Water 116 119 121 126 128 133 135 137 141 141 145 149 153
F Steam 9977 10401 10825 11672 12096 12944 13368 13792 14640 14640 15488 16336 17183
Air 3563 3714 3865 4168 4319 4622 4774 4925 5228 5228 5530 5833 6136
Water 182 186 190 197 201 208 211 215 221 221 228 234 240
G Steam 16346 17041 17735 19125 19819 21208 21903 22597 23986 23986 25376 26765 28154
Air 5837 6085 6333 6829 7077 7573 7821 8069 8565 8565 9061 9557 10053
Water 298 305 311 323 329 341 346 352 363 363 373 383 393
H Steam 25511 26595 27678 29846 30930 33098 34182 35266 37434 37434 39602 41770 43938
Air 9109 9496 9884 10658 11045 11819 12206 12593 13367 13367 14141 14915 15689
Water 466 476 485 504 514 532 540 549 566 566 582 598 614
J Steam 41824 43601 45379 48933 50710 54264 56041 57819 61373 61373 64927 68482 72036
Air 14935 15569 16204 17473 18108 19377 20011 20646 21915 21915 23184 24454 25723
Water 763 780 796 827 842 872 886 900 928 928 955 981 1007
K Steam 59730 62268 64806 69882
Air 21329 22235 23141 24954
Water 1090 1113 1136 1181
L Steam 92715 96655 100595 108474 112413 120292 124232
Air 33107 34514 35921 38734 40141 42954 44361
Water 1692 1728 1764 1833 1867 1932 1964
M Steam 116991 121962 126933 136875 141846 151788 156759
Air 41775 43551 45326 48876 50651 54201 55976
Water 2135 2181 2226 2313 2356 2438 2479
N Steam 141039 147032 153025 165011 171004 182989 188982
Air 50363 52503 54643 58922 61062 65342 67482
Water 2574 2629 2683 2789 2840 2939 2988
Discharge Capacities
Calculation of mass flow acc. to ASME Sec. VIII Div. 1/ API 526
Capacities shown here are indicative. For detailed calculations, please provide the complete process data.
NOTE
Saturated Steam capacity in lb/h Air capacity at 15C in scfm Water capacity in U.S.gpm
FAINGER LESER 2011
-
3/06
Discharge Capacities
Calculation of mass flow acc. to DIN 3320 TRD 421 AD-Markblatt 2000-A2, ISO 4126
NOTE
Capacities shown here are indicative. For detailed calculations, please provide the complete process data.
Saturated Steam capacity in kg/h 3Air capacity at 15C in Nm /h Water capacity in /h3m
Flow SET PRESSURE, bar gMedium
dia mm 32.1 36.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0 75.0 80.0 85.0 90.0 95.0 100.0
18 Steam 2919 3241 3571 3979 4383 4791 5190 5590 5986 6379 6769 7162 7552 7939 8324
Air 5589 6197 6804 7412 8019 8627 9234 9842 10449 11057 11664 12272
Water 39 41 43 45 47 49 50 52 54 55 57 58
23 Steam 4766 5291 5830 6497 7156 7822 8473 9126 9774 10415 11052 11693 12330 12962 13590
Air 9125 10117 11109 12101 13093 14085 15077 16068 17060 18052 19044 20036
Water 64 67 71 74 77 80 82 85 88 90 93 95
29 Steam 7577 8412 9268 10329 11377 12435 13471 14509 15538 16558 17570 18589 19601 20607 21606
Air 14507 16084 17661 19238 20815 22392 23969 25545 27122 28699 30276 31853
Water 102 107 112 117 122 127 131 135 140 144 148 151
37 Steam 12334 13694 15087 16815 18520 20242 21928 23618 25293 26954 28601 30260 31908 33545 35171
Air 23615 26182 28749 31316 33883 36450 39017 41583 44150 46717 49284 51851
Water 165 174 183 191 199 206 213 220 227 234 240 246
46 Steam 19064 21166 23319 25989 28626 31287 33894 36506 39095 41662 44207 46771
Air 36501 40469 44436 48404 52371 56339 60306 64274 68241
Water 255 269 282 295 307 319 330 341 351
60 Steam 32434 36010 39673 44216 48702 53229
Air 62100 68850 75600
Water 435 458 480
74 Steam 49336 54775
Air
Water
3
FL 441
HP Series
Calculation of mass flow acc. to IBR 1950
Capacities shown here are indicative. For detailed calculations, please provide the complete process data.
NOTE
SET PRESSURE, bar g Flow
dia mm 32.1 34 36 38 40 42 44 46 48 50 55 60 65 70
18 3203 3387 3581 3774 3967 4161 4354 4548 4741 4935 5419 5902 6386 6870
23 5230 5530 5846 6162 6478 6794 7110 7425 7741 8057 8847 9637 10426 11216
29 8315 8792 9294 9796 10298 10800 11303 11805 12307 12809 14065 15320 16576 17831
37 13535 14311 15129 15946 16764 17581 18399 19216 20034 20851 22895 24939 26982 29026
46 20920 22120 23384 24647 25911 27175 28438 29702 30965 32229 35388 38546 41705 44864
60 35592 37634 39783 41933 44083 46233 48382 50532 52682 54831 60206
74 54139 57245 60515
(Saturated Steam capacity in kg/h)
FAINGER LESER 2011
-
4/01
CONSTRUCTION TYPE
B - BELLOWS
C - CONVENTIONAL
O - OTHER, TO SPECIFY
SPRING MATERIAL
0 - OTHER, TO SPECIFY
1 - CS CD. PLATED
2 - ALLOY STEEL
4 - STAINLESS STEEL
STANDARD ACCESSORIES
0 - OTHER, TO SPECIFY
2 - CLOSED, SCREWED CAP
4 - PACKED LEVER CAP
09 C S6 S S 44
S - SCREWED
0 - OTHER, TO SPECIFY
MODEL No.
09/CS64SS4
PROCEDURE FOR VALVE SIZING & SELECTION
FLOW DIA
09
MATERIAL TYPECONNECTION RATING
FOR INLET & OUTLET
C6 - CS, ASTM A 216 WCB
(SS 316 TRIM)
S5 - SS, ASTM A 351 CF 8
(SS 316 TRIM)
S6 - SS, ASTM A 351 CF 8M
(SS 316 TRIM)
5L - SS, ASTM A 351 CF 3
(SS 316 L TRIM)
6L - SS, ASTM A 351 CF 3M
(SS 316L TRIM)
00 - OTHER, TO SPECIFY
FL 459
4
Valves manufactured by FAINGER LESER are based on DIN design. Relieving capacity of the selected valve would meet the customer
required capacity. Sizing calculations are according to DIN 3320 / TRD 421, AD-Merkblatt 2000-A, ISO 4126 or
ASME Sec. VIII Div. 1/ API RP 520, where applicable. These Valves are approved by IBR.
/
FAINGER LESER Valves are tested for seat leakage according to API 527.
Method of Model Numbering
For Valve Type FL 459 Series
0 - OTHER, TO SPECIFY
1 - OPEN BONNET
2 - JACKETED TYPE
3 - TEST GAG
6 - STELLITED INLET (SEAT)
AND DISC
8 - DRAIN PLUG
SPECIAL FEATURES/ EXTRA
ACCESSORIES 'X' FOLLOWED
BY THE FOLLOWING NOS.
FAINGER LESER 2011
-
4/02
FL 459
4Safety Relief Valve with Packed Lever Cap, H4
45
44
12
19
85
86
41
46
74
43
75
16
18
9
14
54
16
598
57
61
78
2
60
1
7A
b
c
a
H
FAINGER LESER 2011
-
4FL 459
Part NameItemReco
mm
ended
Main
tenance
Part
s
Inlet Body
Outlet Body
Disc Compl.
Disc Body
Lifting Aid
Securing Ring
Guide
Bonnet
Spindle
Split Ring
Spring Plate
Adjusting Screw
Lock Nut
Name Plate
Spring
Pin
Securing Ring
Gasket
Ball
Lever Cover H 4
Lever H 4
Lifting Fork
Shaft
Spindle Cap
Pin
Spacer
'O' Ring
Support Ring / Gland
Hex. Nut
Lead Seal
Seal Wire
1* = Basic valve assembly
fitted with 2* and 4*
2* = Cap H2, gastight
4* = Lifting device H4,
gastight
1
2
7
7.1
7.2
7.3
8
9
12
14
16
18
19
50
54
57
59
60
61
41
43
44
45
46
74
75
79
80
82
85
86
4*
2*
1*
2*
4*
Assembly of Screwed Full Lift Valve
4/03
1*Cap H 2
Spacer
Lead Seal
Seal Wire
42
75
85
86
42
41
44
91
46
74
18
19
16
12
54
59
14
61
16
7.1
57
7.3
7.2
8281
83
43
8084
77
4579
75
86
85
9
60
8
60
2
1
7
50
FAINGER LESER 2011
-
Note: The above material is for standard construction. Suitable material to be used for corrosion resistant/special application.
-60
-76
-10
14
200
392
300
572
540
1000
DIN 1.4310 (SS)
DIN 1.8159 (ALLOY STEEL)
DIN 1.1200 (CS)
-268
-268
-450
-450
-102
-151
-29
-21
427
800
540
10000
F
0
F
0
C
0
C
ASTM A 351 CF 8/8M
ASTM A 352 LCB ASTM A 216 WCB
ASTM A 217 WC6
TEMPERATURE Vs. MATERIAL OF CONSTRUCTION
SPRING
BODY
FL 459
4
STANDARD MATERIAL (Also Refer to Method of Model Numbering for Details)
C61 S54 / S64PART NAMETYPE
PART
No.
C L
O S
E D
C
A P, H
2PA
CK
ED
LEVER,
H4
INLET BODY
OUTLET BODY
DISC
SPINDLE GUIDE
BONNET
SPINDLE
SPLIT RING
SPRING PLATE
ADJUSTING SCREW
LOCK NUT
CAP (41)
SPRING
ROLL PIN
SECURING RING
GASKET
BALL
SPACER
LEAD SEAL
SEAL WIRE
LEVER
LIFTING FORK
LEVER SHAFT
SPINDLE CAP
PIN
GLAND
HEX. NUT
AISI 316
CS
AISI 316
AISI 316
CS
AISI 316
AISI 316
CS CD. PLATED
AISI 316
AISI 316
CS
CS CD. PLATED / ALLOY STEEL / SS
SS
SS
C.A.F. / NON ASBESTOS
SS
C.A.F. / NON ASBESTOS
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
CS
CS
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
SS
SS
SS
C.A.F. / NON ASBESTOS
SS
C.A.F. / NON ASBESTOS
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
AISI 316
SS
The Valves can be provided with Bellows
NOTE
Standard Materials
4/04
1
2
7
8
9
12
14
16
18
19
42
54
57
59
60
61
75
85
86
43
44
45
46
74
80
82
FAINGER LESER 2011
-
Calculation of mass flow according to AD-Merkblatt 2000 - A2, ISO 4126
Size (mm) 20 x 25, 25 x 25
do (mm) 9.0
Set I II III
pressure Saturated Steam Air at 0C and Water at 20C
(bar g) (kg/h) 1013 mbar (Sm/h) (10 kg/h)
100 3296 3991 20.7
150 5438 5969 25.4
200 7946 29.3
250 9924 32.7
300 11902 35.9
350 13879 38.7
400 15857 41.4
Discharge Capacities4
FL 459
4/05
1
2
20
25
25
25300.0 75 4.09.0 66
Inlet
mm
Outlet
mm
Height
(approx.)
H
mm
Inlet
a+c
mm
Outlet
b
mm
Weight
(approx.)
kgs
Flow dia
do
mm
Sl.
No.
Overall Dimensions
Size
100-440
Set
Pressure
bar g
Center to Face
FAINGER LESER 2011
-
CONSTRUCTION TYPE
C - CONVENTIONAL
O - OTHER, TO SPECIFY
SPRING MATERIAL
0 - OTHER, TO SPECIFY
1 - CS CD. PLATED
4 - STAINLESS STEEL
STANDARD ACCESSORIES
0 - OTHER, TO SPECIFY
2 - CLOSED, SCREWED CAP
4 - PACKED LEVER CAP
10 C S6 S S 44
S - SCREWED
0 - OTHER, TO SPECIFY
MODEL No.
10/CS64SS4
PROCEDURE FOR VALVE SIZING & SELECTION
FLOW DIA
10
12.5
MATERIAL TYPECONNECTION RATING
FOR INLET & OUTLET
C6 - CS, ASTM A 216 WCB
(SS 316 TRIM)
S5 - SS, ASTM A 351 CF 8
(SS 316 TRIM)
S6 - SS, ASTM A 351 CF 8M
(SS 316 TRIM)
5L - SS, ASTM A 351 CF 3
(SS 316 L TRIM)
6L - SS, ASTM A 351 CF 3M
(SS 316L TRIM)
HS - ASTM A 217 GR. WC6
(SS 316 TRIM)
LS - ASTM A 352 GR. LCB
(SS 316 TRIM)
AY - ALLOY - 20
(ALLOY - 20 TRIM)
HY - HASTELLOY - 'C'
(HAST. - 'C' TRIM)
SP - SPECIAL
C8 - CS, ASTM A 216 WCB
(SS 316 L TRIM)
00 - OTHER, TO SPECIFY
FL 539
Method of Model Numbering
For Valve Type FL 539 Series
5/01
5
Valves manufactured by FAINGER LESER are based on DIN design. Relieving capacity of the selected valve would meet the customer
required capacity. Sizing calculations are according to DIN 3320 / TRD 421, AD-Merkblatt 2000-A2, ISO 4126 or ASME Sec. VIII
Div. 1/ API RP 520, where applicable.
1
2
3
15
15
20
15
20
20
180
180
180
33
33
33
0.9
1.0
1.1
01
02
03
10
10
12.5
48
48
48
Inlet
mm
Outlet
mm
Height
(approx.)
H
mm
Inlet
a+c
mm
Outlet
b
mm
Weight
(approx.)
kgs
Designation
Flow dia
do
mm
Sl.
No.
Overall Dimensions
Note: Valves with special connections and center to face dimensions can also be provided on request.
/
FAINGER LESER Valves are tested for seat leakage according to API 527.
Center to face Size
Note:
For Flow dia 12.5mm,
the model No. would
read as 12/.....
FAINGER LESER 2011
-
5/02
FL 539
5Safety Valve with Packed Lever Cap, H4
1
60
61
7
57
59
27
16
12
54
19
17
9
18
b
c
a+
c
a
~H
41
79
43
74
46
74
85
75
86
FAINGER LESER 2011
-
FL 539
Assembly of a Spring Loaded Safety Valve5
5/03
Inlet Body
Disc Compl.
Bonnet
Spindle
Lower Spring Plate
Upper Spring Plate
Adjusting Screw
Lock Nut
Guide
Name Plate
Spring
Pin
Securing Ring
Gasket
Ball
1
7
9
12
16
17
18
19
27
50
54
57
59
60
61
1*= Basic valve assembly
fitted with 2* and 4*
Cap H2
Spacer
42
75
2* = Cap H2, gastight
no lifting gear
Part NameItem
1*
2*
4*
Lever Cover H4
Lever H4
Spindle Cap
Pin
Spacer
O-ring
41
43
46
74
75
79
4*= Lifting Gear H4,
gastight construction
2*
4*
Stainless Steel Bonnet
42
75
43
79
74
41
75
50
18
19
9
74
27
60
57
46
17
12
54
59
16
61
7
1 7
FAINGER LESER 2011
-
5/04
Standard Materials
FL 539
5
STANDARD MATERIAL (Also Refer to Method of Model Numbering for Details)
C61 S54/S64PART NAMETYPE
PART
No.
C L
O S
E D
C
A P
, H
2PA
CK
ED
LEVER,
H4
Note: The above material is for standard construction. Suitable material to be used for corrosion resistant/special application.
-60
-76
-10
14
200
392
300
572
540
1000
DIN 1.4310 (SS)
DIN 1.8159 (ALLOY STEEL)
DIN 1.1200 (CS)
-268
-268
-450
-450
-102
-151
-29
-21
427
800
540
10000
F
0
F
0
C
0
C
ASTM A 351 CF 8/8M
ASTM A 352 LCB ASTM A 216 WCB
ASTM A 217 WC6
TEMPERATURE Vs. MATERIAL OF CONSTRUCTION
1
7
9
12
16
17
18
19
27
42
54
57
59
60
61
75
85
86
43
46
74
79
Inlet Body
Disc Complete
Bonnet
Spindle
Lower Spring plate
Upper Spring plate
Adjusting Screw
Lock Nut
Guide
Cap (41)
Spring
Roll Pin
Securing Ring
Gasket
Ball
Spacer
Lead Seal
Seal Wire
Lever, H4
Spindle Cap
Pin
"O" Ring
AISI 316
AISI 316
A 216 Gr. WCB
AISI 316
AISI 316
CS CD. PLATED
AISI 316
AISI 316
AISI 316
CS
CS CD. PLATED
SS
SS
C.A.F. / NON ASBESTOS
SS
C.A.F. / NON ASBESTOS
LEAD
MS
CS
AISI 316
SS
NEOPRENE/VITON
AISI 316
AISI 316
A 351 Gr. CF 8/8M
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
--
AISI 316
SS
SS
SS
C.A.F. / NON ASBESTOS
SS
C.A.F. / NON ASBESTOS
LEAD
MS
AISI 316
AISI 316
SS
NEOPRENE/VITON
FAINGER LESER 2011
-
Discharge Capacities
Calculation of mass flow according to AD-Merkblatt 2000 - A2, ISO 4126
I- Saturated Steam kg/h II - Air at 0 C (32 F) and 1013,25 mbar absolute (scm/h) III - Water at 20 C (68 F) (kg/h)
do 10 12.5
p (bar g) I II III I II III
0,5 21 25 734 26 32 927
1 29 36 1039 37 46 1311
1,5 38 47 1272 46 59 1605
2 45 58 1469 56 72 1854
2,5 53 68 1642 66 85 2073
3 60 77 1799 76 97 2270
3,5 67 87 1943 85 109 2452
4 75 97 2077 94 121 2622
4,5 82 106 2203 103 134 2781
5 89 116 2322 112 146 2931
6 103 135 2544 130 170 3211
7 118 154 2748 148 194 3468
8 132 174 2938 166 218 3707
9 146 193 3116 184 243 3932
10 160 212 3284 202 267 4145
12 189 251 3598 238 315 4541
14 217 289 3886 274 364 4905
16 246 328 4155 309 412 5243
18 274 366 4407 345 461 5561
20 303 405 4645 381 509 5862
22 331 443 4872 417 558 6148
24 360 482 5088 453 606 6422
26 389 520 5296 489 655 6684
28 418 559 5496 526 703 6936
30 446 587 5689 562 751 7179
32 475 636 5875 598 800 7415
34 505 674 6056 635 848 7643
36 534 713 6232 672 897 7865
38 563 751 6403 709 945 8080
40 592 790 6569 746 994 8290
42 622 828 6731 783 1042 8495
44 651 867 6890 820 1091 8695
46 681 905 7044 857 1139 8890
48 711 944 7196 895 1188 9081
50 741 982 7344 933 1236 9269
55 816 1078 7703 1028 1357 9721
60 893 1175 8045 1124 1478 10153
65 970 1271 8374 1221 1600 10568
70 1048 1367 8690 1319 1721 10967
75 1127 1463 8995 1418 1842 11352
80 1207 1560 9290 1519 1963 11724
85 1288 1656 9576 1621 2084 12085
90 1370 1752 9853 1724 2205 12435
95 1452 1848 10123 1828 2327 12776
100 1536 1945 10386 1934 2448 13108
105 2041 10643 2569 13432
110 2137 10893 2690 13748
115 2233 11138 2811 14057
120 2330 11378 2932 14359
125 2426 11612 3054 14655
130 2522 11842 3175 14945
135 2618 12068 3296 15230
140 2715 12289 3417 15509
145 2811 12507 3538 15784
150 2907 12721 3659 16054
5
FL 539
5/05FAINGER LESER 2011
-
FL 549
6
CONSTRUCTION TYPE
C - CONVENTIONAL
O - OTHER, TO SPECIFY
SPRING MATERIAL
0 - OTHER, TO SPECIFY
1 - CS CD. PLATED
4 - STAINLESS STEEL
STANDARD ACCESSORIES
0 - OTHER, TO SPECIFY
2 - CLOSED, SCREWED CAP
4 - PACKED LEVER CAP
19 C S6 2 2 4 X34
0 - OTHER, TO SPECIFY
1 - OPEN BONNET
2 - JACKETED TYPE
3 - TEST GAG
4 - 'O' RING DISC
6 - STELLITED INLET (SEAT)
& DISC
8 - DRAIN PLUG
SPECIAL FEATURES/EXTRA ACCESSORIES
'X' FOLLOWED BY THE FOLLOWING NOS.
A - ANSI 150 #
B - ANSI 300 #
C - ANSI 600 #
D - ANSI 900 #
E - ANSI 1500 #
F - ANSI 2500 #
0 - OTHER, TO SPECIFY
S - SCREWED
1 - PN 10
2 - PN 16
3 - PN 25
4 - PN 40
5 - PN 64
6 - PN 100
7 - PN 160
MODEL No.
19/CS64224X3
MATERIAL TYPEORIFICE
DESIGNATION
04
06
07
08
11
19
20
30
31
C6 - CS, ASTM A 216 WCB
(SS 316 TRIM)
S5 - SS, ASTM A 351 CF 8
(SS 316 TRIM)
S6 - SS, ASTM A 351 CF 8M
(SS 316 TRIM)
5L - SS, ASTM A 351 CF 3
(SS 316 L TRIM)
6L - SS, ASTM A 351CF 3M
(SS 316 L TRIM)
CH - CS, ASTM A 216 WCB
(HASTELLOY C TRIM)
SM - SS, ASTM A 351 CF 8M
(MONEL TRIM)
HS - ASTM A 217 GR. WC6
(SS 316 TRIM)
LS - ASTM A 352 GR. LCB
(SS 316 TRIM)
AY - ALLOY - 20
(ALLOY - 20 TRIM)
HY - HASTELLOY - 'C'
(HASTELLOY- 'C' TRIM)
SP - SPECIAL
00 -
FLF - 549 is for Flanged type and FLS - 549 is for Screwed type construction.
Other special material also available. Please check specific quotation for model number
Valves manufactured by FAINGER LESER are based on DIN design. Relieving capacity of the selected valve would meet the customer
required capacity. Sizing calculations are according to DIN 3320 / TRD 421, AD-Merkblatt 2000 - A2, ISO 4126 or ASME Sec. VIII
Div. 1 / API RP 520, where applicable. These valves are approved by the CCoE (Chief Controller of Explosives), Nagpur.
FAINGER LESER Valves are tested for seat leakage according to API 527.
PROCEDURE FOR VALVE SIZING & SELECTION
6/01
/
CONNECTION RATING
FOR INLET & OUTLET
NOTE
Method of Model Numbering
For Valve Type FL 549 Series
Note:
For Flow dia 12.5mm,
the model No. would
read as 12/.....
FLOW DIA
08
12.5
16
FAINGER LESER 2011
-
FL 549
6S
(Screwed Type FLS-549)
afety Valve with Packed Lever Cap, H4
6/02
~ H
b
ca
a +
c
46
74
43
12
75
16
9
54
14
60
8
2
7
60
1
61
57
45
44
41
86
85
19
18
59
FAINGER LESER 2011
-
Safety Valve with Packed Lever Cap, H4(Flanged Type FLF-549)
FL 549
6
6/03
H~
e
d
60
1
48
61
57
7
2
8
14
9
54
16
75
12
43
74
60
59
18
19
86
85
41
44
45
46
FAINGER LESER 2011
-
FL 549
6
6/04
Assembly of a Spring Loaded Safety Valve
18
85
86
9
60
8
60
2
61
1
7
57
14
16
42
75
2*
4*
41
44
90
43
83
80
4579
75
19
Inlet Body
Outlet Chamber
Disc Compl.
Spindle Guide
Bonnet
Spindle
Split Ring
Spring Plate
Adjusting Screw
Lock Nut
Name Plate
Spring
Pin
Securing Ring
Gasket
Ball
1
2
7
8
9
12
14
16
18
19
50
54
57
59
60
61
1*= Basic valve assembly
fitted with 2*and 4*
Cap H2
Spacer
Lead Seal
Seal Wire
Lever Cover H4
Lever H4
Lifting Fork
Shaft
Spindle Cap
Pin
Spacer
O ring
Circlip
Lead Seal
Seal Wire
42
75
85
86
41
43
44
45
46
74
75
79
80
83
85
86
2 * = Cap H2, gastight
no lifting gear
4*= Lifting Gear H4,
gastight construction
Part NameItem
1*
2*
4*
46
16
74
12
54
59
50
Supporting Ring/Gland
FAINGER LESER 2011
-
Note: The above material is for standard construction. Suitable material to be used for corrosion resistant/special application.
-60
-76
-10
14
200
392
300
572
540
1000
DIN 1.4310 (SS)
DIN 1.8159 (ALLOY STEEL)
DIN 1.1200 (CS)
-268
-268
-450
-450
-102
-151
-29
-21
427
800
540
10000
F
0
F
0
C
0
C
ASTM A 351 CF 8/8M
ASTM A 352 LCB ASTM A 216 WCB
ASTM A 217 WC6
TEMPERATURE Vs. MATERIAL OF CONSTRUCTION
SPRING
BODY
FL 549
6Standard Materials
6/05
STANDARD MATERIAL (Also Refer to Method of Model Numbering for Details)
C61 S54 / S64 SPECIAL-1PART NAMETYPE
PART
No.
C L
O S
E D
C
A P, H
2PA
CK
ED
LEVER,
H4
1
2
7
8
9
12
14
16
18
19
42
48
54
57
59
60
61
75
85
86
43
44
45
46
74
80
82
INLET BODY
OUTLET CHAMBER
DISC
SPINDLE GUIDE
BONNET
SPINDLE
SPLIT RING
SPRING PLATE
ADJUSTING SCREW
LOCK NUT
CAP (41)
INLET FLANGE
SPRING
ROLL PIN
SECURING RING
GASKET
BALL
SPACER
LEAD SEAL
SEAL WIRE
LEVER
LIFTING FORK
LEVER SHAFT
SPINDLE CAP
PIN
GLAND
HEX. NUT
AISI 316
A 216 Gr. WCB
AISI 316
AISI 316
A 216 Gr. WCB
AISI 316
AISI 316
CS CD. PLATED
AISI 316
AISI 316
A 216 Gr. WCB
CS
CS CD. PLATED
SS
SS
C.A.F. / NON ASB.
SS
C.A.F. / NON ASB.
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
CS
CS
AISI 316
A 351 Gr. CF 8/8M
AISI 316
AISI 316
A 351 Gr. CF 8/8M
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
A 351 Gr. CF 8/8M
AISI 316
SS
SS
SS
C.A.F. / NON ASB.
SS
C.A.F. / NON ASB.
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
AISI 316
SS
HASTELLOY-C/MONEL
A 351 Gr. CF 8M
HASTELLOY-C/MONEL
AISI 316
A 351 Gr. CF 8M
AISI 316
AISI 316
AISI 316
AISI 316
AISI 316
A 351 Gr. CF 8M
AISI 316
SS
SS
SS
C.A.F. / NON ASB. / PTFE
SS
C.A.F. / NON ASB. / PTFE
LEAD
MS
CS
SS
AISI 316
AISI 316
SS
AISI 316
SS
Material of construction will vary according to the service conditions and customer requirement. Other special materials, for example, Monel,
Alloy-20, CF 3, CF 3M and accessories such as Test Gag, Heating Jacket, Drain Plug, Soft Seat (O-Ring) Disc etc.. can be provided on request.
NOTE
FAINGER LESER 2011
-
@ The flow Dia 'do' shall be 8.0mm for set pressure above 113.0 bar g while using C.S. Spring and 95.0 bar g
while using S.S. Spring.
* Outlet size of 25 mm is standard, however, 20 mm can also be provided on request for flow Dia, 8.0mm
Special sizes & connections or different center to face dimensions etc. can also be provided on request.
6/06
Overall dimensions
FL 549
6FLANGED TYPE (FLF-549 Series)
SCREWED TYPE (FLS-549 Series)
Sl.
No.
mm
Inlet
d
mm
Inlet
mm
Outlet
e
mm
Outlet
Height
(approx)
H
mm
Weight
Approx.
kgs.
Flow dia
do
mm
Dia.
d
mmsq. in. sq. mm
1
2
3
4
5
6
7
8
9
15
20
25
25
25
25
25
40
40
25*
25
25
25
40
40
50
40
50
300
300
300
300
300
310
310
310
310
90
90
90
90
90
105
105
105
124
80
80
80
80
80
114
114
114
121
3.0
3.0
3.5
3.5
4.0