fall09 wilson
DESCRIPTION
cvTRANSCRIPT
![Page 1: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/1.jpg)
Statistical Considerations for Implementing the FDA CV
Guidance for T2DM
Craig Wilson, PhDNIC-ASA Fall Meeting
October 15, 2009
![Page 2: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/2.jpg)
Regulatory History (1)
• Rosiglitazone (Avandia; GSK)– TZD for treatment of T2DM– Nissen and Wolski (May 2007)
• Meta-analysis of 42 studies (Ph2/3/4)– Increased risk of MI (OR=1.43; 95%CI [1.03, 1.98])– Possible increased risk of CV death (OR=1.64; 95%CI
[0.98, 2.74])
• Resulted in FDA black box warning
– Questions regarding validity of analysis• 6 of 48 studies excluded with no events
![Page 3: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/3.jpg)
Regulatory History (2)
• FDA Advisory Committee Meeting (July 2008)– Need for data to assess CV risk in T2DM– Endpoints for consideration– Reasonable NI margin for risk ratio to rule out
excess CV risk
![Page 4: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/4.jpg)
FDA CV Guidance for T2DM (1)
• Final guidance issued December 2008– Largely influenced by June 2008 advisory
committee meeting– Will be folded into draft FDA DM guidance
(February 2008) by end of 2009
• Key message: All development programs for T2DM should rule out “unacceptable increase in CV risk”
![Page 5: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/5.jpg)
FDA CV Guidance for T2DM (2)
• Programs should analyze “important CV events”• Suggests CV mortality, MI, stroke (core MACE)• Suggests hospitalization for ACS, urgent
revascularization, “other endpoints” should be adjudicated– Only core MACE + hospitalization for unstable angina likely to
be accepted as primary endpoint per DIA meeting (September 2009)
• Offers guidance for new and existing development programs
• Investigational drugs must not increase CV risk by more than 80% vs. control to initially market; definitely rule out 30% increase to continue on market
![Page 6: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/6.jpg)
New Studies/Programs• Prospective adjudication• High-risk population
– Advanced disease (eg, recent event or long duration of diabetes)
– Elderly– Renally impaired
• Meta-Analysis (Pooled Analysis)– Should include Ph2/3 studies– Comparison vs. control (placebo and/or active)– Long-term data (eg, ≥2 years)
• Stand-alone trial– Might also pool with other analyses
![Page 7: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/7.jpg)
Existing Studies/Programs
• “Meta-analysis” of Ph2/3 data• “Unacceptable risk” margins discussed in
context of upper bound of 2-sided 95% CI for risk ratio vs. control– >1.8 Safety trial needed (stand-alone or
pool with Ph2/3 data) to market– Between 1.3 and 1.8 + favorable risk-benefit
market + post-market trial to rule out 1.3– <1.3 + favorable risk-benefit market; post-
market trial “generally may not be necessary”
![Page 8: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/8.jpg)
Stand-Alone Trial Considerations
• Stand-alone trial: “…if the data from all the studies that are part of the meta-analysis will not by itself be able to show that the upper bound of the 2-sided 95% CI is <1.8, then an additional single, large safety trial should be conducted that alone, or added to other trials, would be able to satisfy this upper bound before NDA/BLA submission.”
• Stand-alone or pooled approach can also be used if between 1.3 and 1.8
• Guidance doesn’t address combining 1.8 and 1.3 analyses in same trial
• Guidance introduces possibility of approval for <1.8 when true risk ratio is 1.3
![Page 9: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/9.jpg)
Advisory Committee Meetings
• Conducted in April 2009– SMQ MACE: CV-related events (serious or
non-serious) based on MedDRA SMQs– Custom MACE: CV-related events (serious or
non-serious) identified by FDA
![Page 10: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/10.jpg)
Saxagliptin
• Onglyza; DPP-4 inhibitor; developed by BMS
• Presentation included controlled data up to 1 year
• Had favorable risk ratios– SMQ MACE (RR=0.85; 95% CI [0.52, 1.42])– Custom MACE (RR=0.2; 95% CI [0.04, 0.79])
• Approved by FDA in August 2009
![Page 11: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/11.jpg)
Liraglutide
• Victoza; GLP-1; developed by Novo Nordisk• Presentation included controlled data up to 1
year• Had less favorable risk ratios
– SMQ MACE (RR=0.9; 95% CI [0.56, 1.31])– Custom MACE (RR=0.7; 95% CI [0.32, 1.57])
• Data comparing to placebo alone not as favorable
• Approved by EMEA in June 2009; still awaiting FDA approval
![Page 12: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/12.jpg)
DIA Meeting
• Held September 2009• Core MACE (CV death, MI, stroke) only agreed primary
endpoint– Concerns regarding unstable angina adjudication (ability to
capture only serious/significant cases)– Some flexibility may exist for UA in the future
• Traditional statistical approaches encouraged (non-adaptive)– Concerns about Type 1 error protection
• Total of 18 CV study designs submitted to FDA so far• Suggestions that EMEA may follow a more “holistic”
approach to assessing CV risk than FDA
![Page 13: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/13.jpg)
Possible Stand-Alone Trial Designs (1)
• Stand-alone trial most robust way to rule out CV risk– FDA prefers placebo comparison per
guidance
• Few opportunities to determine scope of possible analyses acceptable to FDA
• Must rely on reasonable available methods
![Page 14: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/14.jpg)
Possible Stand-Alone Trial Designs (2)
• Time-to-event analysis (Cox regression) seemingly most appropriate analysis method– Reasonably simple and widely understood– Easily generates required hazard margin– Specific methods not stated in FDA guidance;
however, method should account for potential non-constant hazard
– Intent to treat• Survival function specification may rely on
completed trial– Proportional hazards assumption?– Implications of interim analyses?
![Page 15: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/15.jpg)
Possible Stand-Alone Trial Designs (3)
• Traditional analysis– Single analysis after 611 events to rule out
1.3– Pros: Widely accepted; no concern about
Type 1 error control– Cons: One-and-done scenario; time
consideration if needed to market
![Page 16: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/16.jpg)
Possible Stand-Alone Trial Designs (4)
• Separate trials (Fleming; DIA)– Conduct one trial to rule out 1.8 (122 events)– Conduct a separate trial (611 events) to rule
out 1.3– Pros: Widely accepted; no concern about
Type 1 error control– Cons: Still one-and-done scenarios; what if
margin barely missed? What if trials give conflicting results? Cost considerations
![Page 17: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/17.jpg)
Possible Stand-Alone Trial Designs (5)
• Traditional analysis with single step-down interim look– Analyze after 122 events to rule out 1.8– If successful, continue to 611 events to rule
out 1.3; otherwise, declare futility and stop the trial
– Pros: Efficient use of study population– Cons: Prevents assessment of 1.3 if 1.8 can’t
be ruled out; power reduction to rule out 1.3 without more events
![Page 18: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/18.jpg)
Possible Stand-Alone Trial Designs (6)
• Adaptive monitoring (Connor and Berry; January 2009)– Currently being used for CV trial for Libigel (BioSante) to rule out
an upper bound of 2.0– Could be modified to current CV guidance– Use predictive probabilities to monitor accrual and likelihood of
trial success (<1.3)– Conduct periodic pre-planned analyses
• Stop accrual for high predictive probability of trial success• Declare futility for low predictive probability of trial success• Stop trial for success when upper bound of CI is <1.3
– Type 1 error and power confirmed via simulation– Pros: Allows frequent monitoring of trial; potentially reduces
total subjects enrolled; may allow interim monitoring to rule out 1.8
– Cons: Potential for regulatory agencies to be skeptical, given strong interest in Type 1 error protection (DIA meeting)
![Page 19: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/19.jpg)
Possible Stand-Alone Trial Designs (7)
• Group sequential design (Fleming; DIA)– Analyze after 122 events to rule out 1.8– If successful, continue to 611 events to rule out 1.3;
use alpha-spending function (OBF) to control Type 1 error for 2 analyses
– Pros: Efficient use of study population; still allows assessment of 1.3 even if 1.8 can’t be ruled out
– Cons: Would potentially require more time to market (if 1.8 can’t be ruled out); difficult to rule out 1.8 at interim unless true hazard highly favorable; may require more events than stated to maintain desired power
![Page 20: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/20.jpg)
Possible Stand-Alone Trial Designs (8)
• Group sequential design with step-down– Use alpha-spending function (OBF) and repeated CIs
to rule out 1.8 (Durrleman and Simon [1990])– If successful, use separate alpha-spending function
(OBF) and repeated CIs to rule out 1.3; otherwise, stop the trial for futility
– Pros: Efficient use of study population; provides more power to rule out 1.8 if true hazard is close to 1.0; provides early assessment to rule out 1.8
– Cons: Prevents assessment of 1.3 if 1.8 can’t be ruled out; potential power reduction to rule out 1.3 without adding more events
![Page 21: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/21.jpg)
Superiority?
• Could design from beginning as superiority trial using traditional approach– Would likely require substantial data– Unlikely to get label claim
• Step-down analysis once 1.3 ruled out?– Dependent on proximity of upper 95% CI
bound to 1.3– Adaptive design likely best suited for task– How long do you look?
![Page 22: Fall09 wilson](https://reader033.vdocument.in/reader033/viewer/2022051313/54832dd8b47959140d8b496d/html5/thumbnails/22.jpg)
Questions?