Auto-swing Auto-air direction control5-level air direction setting
10°
70°Auto-swing from 10° to 70°
S ettable to 5 different levels between 10° to 70°
The air direc tion is set automatic ally to the memorised pos ition of the previous air direc tion. (Initial setting is 10° for c ooling and 70° for heating.)
10°
70°
10°
70°
Drastic size reduction
Reduced size (by 22% in volume, 32% in installation area)makes installation possible in a very limited space.
Sophisticated extension design
Easier to install and service
Compact and stylish design that does not detract from the decor of the room.
Improved airflow modes realise comfortable air distribution across the entire room
Switchable fan speed: High/Low
Programme "Dry"
To carry air to the far side of long rooms, extra-high airflow adds 10% more fan speed the "high" setting. Air discharge strength is selected from the remote controller.
Conventional(FAY71FAVE)
New model
21 Kg 13 Kg
Easier to install and service
Maintenance possible from the front of the unitAll maintenance tasks can be carried out via front access. During service work, attachment and detachment of parts is easier.
Low gas pressure detectionInsufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure.
WALL MOUNTED TYPE
Made more compact, stylish, and quieter
23 24Guide Line up
P. 3–4, 7–8Outdoor unitsP. 33–34
OptionsP. 58
Outer dimension drawingsP. 62, 63
Remote controllersP. 35–36
Standard specificationsP. 41, 51
Two selectable temperature-sensorsBoth indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control.
Flap is closed when not operating
Drain pan and air filter can be kept clean by mould-proof polystyrene
Removable and washable grille
DIII-NET connection is standard specification. Adapter is not required.
Light weightReduced weight by 8kg greatlyfacilitates installation.
*Temperature-sensor on indoor unit must be used when the air c onditioner is c ontrolled from another room.
**Wireless remote c ontroller does not have a
BRC7E619
Wired LCD remote controller Wireless LCD remote controllerA s ignal rec eiver must be added to the indoor unit.
Wireless remote c ontroller and s ignal rec eiver unit are sold as a set.
Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally.
Accessory required for indoor unit (option)
BRC1C61
Cooling only
BRC7EA618Heat pump
BRC7C611WCooling only
BRC7C610WHeat pump
WALL MOUNTEDTYPE
FAYFAY71LVE / FAY100FAVECooling onlyFAY71LVE / FAY100FAVE
FAY71LVE
FAY71L
FAY100F
FAY100FAVE
Heat pump
MouldpreventionComfort Work & Servicing Control features Others
Features (Features are explained on P. 37–38.)Feature
Model
Heat pumpCooling only
*1Applic able when wired remote c ontroller is used*2Applic able to R 71LU/R 100LU outdoor units (for temp. down to – 15°C ) (An option is required.)*3Applic able to R Y71LU/R Y100LU outdoor units (for temp. down to – 5°C )*4Applic able to R (Y)71LU/100LU outdoor units
Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
*4
*4
*4
*4
*1
*1
*3
*2
Sw
itch
ab
le
fan
sp
ee
d
Au
to
swin
g
Pro
gra
mm
e
"Dry
"
Hig
h
fan
sp
ee
d
mo
de
Dra
ft
pre
ven
tion
fu
nc
tion
Up
wa
rd
Ho
t st
art
Ye
ar-
rou
nd
c
oo
ling
a
pp
lica
ble
Tim
er
sele
cto
r
Pre
c
ha
rge
d
for
up
to
3
0
m
Dra
in
pu
mp
m
ec
ha
nis
m
Mo
uld
-pro
ofin
g
dra
in
pa
n
Mo
uld
re
sist
an
t tr
ea
tme
nt
for
filte
r
Filt
er
sig
n
Lo
w
ga
s p
ress
ure
d
ete
ctio
n
Em
erg
en
cy
op
era
tion
Se
lf-d
iag
no
sis
fun
ctio
n
Co
ntr
ol
by
2
rem
ote
c
on
tro
llers
Au
to-c
oo
ling
/he
atin
g
ch
an
ge
-ove
r
Au
to-r
est
art
PE
fin
Co
ntr
ol
by
1
rem
ote
c
on
tro
ller
Ext
ern
al
co
mm
an
d
co
ntr
ol
Ce
ntr
al
rem
ote
c
on
tro
l
Inte
rlo
ck
co
ntr
ol
Tw
o
sele
cta
ble
te
mp
era
ture
-se
nso
rs
1,050 mm
290 mm
-70 mm-200 mm
(FAY71FAVE)Conventional model
Height of drain up
Drain-pump kitIndoor unit
Installs onto side of unit.
1,000 mm
(Available to be installed onto right side.)
Comfort even on the far side of the room
Drain enclosure can be used on either left and right side.
Drain pump kit is available as option.
Below features only apply to FAY71L.
Signal receiver unit(Installed type)
(FAY71LVE)
45/41dB(A)FAY100FA
High Low
Sound level
43/37dB(A)FAY71L
High Low
Sound level
-
Guide Existing models:P.3 ~ 4
Outdoor units:P.25 ~ 26
Options:P.36 ~ 37
Outer dimension drawings:P.38 ~ 45
Remote controllers:P.27 ~ 28
Standard specifications:P.34
Guide Line up P. 3–4, 7–8
Outdoor unitsP. 33–34
OptionsP. 58
Outer dimension drawingsP. 63
Remote controllersP. 35–36
Standard specificationsP. 42, 52
Note: For optimal installation, space factors should be accurately calculated.
FLOOR STANDING TYPE
A good choice for spaces with ceilings so high that heating by ceiling-mounted units is inefficient.
Vertical airflow adjustment is possible when (changing between cooling and heating or) to match interior spaces and partitions.
Auto-swing Manual setting of vertical airflow louvers
71LA 41 35
Quiet operation Easier to install and service
LightweightIndoor unit High Low
125LA 49 43100LA 46 40
The unit can be easily transported and installed.
Auto-swing delivers comfort to every corner of the room
FVY units have swinging louver spreads comfortable airflow. Any uncomfortable sensation of sudden change is avoided by a slow cycle of 2 to 3 full swings per minute.
Switchable fan speed: High/Low
Long-life filter lasts about 1 year * Maintenance not required*For dust concentration of 0.15 mg/m3
Dehumidification is microprocessor con-trolled to prevent abrupt and uncomfort-able changes in air temperature.
Low gas pressure detectionInsufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure.
The floor-standingconfiguration meansthe FVY is easy to installand maintain. It can also be installedunder high ceilings.
Easy-to-operate, handy LCD control panel
The LCD displays text, numbers and graphics to indicate the temperature setting, timer setting, auto-swing, fan speed, and more. Furthermore, the LCD panel can be detached and used as a remote controller, so air conditioning can be controlled from another room or from the cash register. (Remote controller cable not included. Cables must be procured locally.)
Programme "Dry"
25 26
Note: This remote c ontroller has a temperature-sensor.
71 class 45 kg 39 kg
Indoor unit ConventionalFVY-F New model
125 class 67 kg 47 kg100 class 63 kg 46 kg
Weight
Two selectable temperature-sensorsTemperature-sensors on both indoor unit and wired remote controller. Temperature sensing can be set closer to the target area to further improve comfort level.
2 weeks AnnualConventional
filterLong-life filter
Filter exchange intervalLCD control panel is standard
FLOOR STANDINGTYPE
FVYFVY71LAVE–125LAVECooling onlyFVY71LAVE–125LAVEHeat pump
MouldpreventionComfort Work & Servicing Control features Others
Features (Features are explained on P. 37–38.)Feature
Model
Heat pumpCooling only
*1Applic able to R 71LU– R 125LU outdoor units (for temp. down to – 15°C ) (An option is required.)*2Applic able to R Y71LU– R Y125LU outdoor units (for temp. down to – 5°C ) *3Applic able to R (Y)71LU– 125LU outdoor units
*3
*3
*3
*3
*2
*1
Sw
itch
ab
le
fan
sp
ee
d
Au
to
swin
g
Pro
gra
mm
e
"Dry
"
Ho
t st
art
Tw
o
sele
cta
ble
te
mp
era
ture
-se
nso
rs
Ye
ar-
rou
nd
c
oo
ling
a
pp
lica
ble
Tim
er
sele
cto
r
Pre
c
ha
rge
d
for
up
to
3
0
m
Lo
ng
-life
fil
ter
Mo
uld
re
sist
an
t tr
ea
tme
nt
for
filte
r
Filt
er
sig
n
Lo
w
ga
s p
ress
ure
d
ete
ctio
n
Em
erg
en
cy
op
era
tion
Se
lf-d
iag
no
sis
fun
ctio
n
Co
ntr
ol
by
2
rem
ote
c
on
tro
llers
Au
to-c
oo
ling
/he
atin
g
ch
an
ge
-ove
r
Au
to-r
est
art
Co
ntr
ol
by
1
rem
ote
c
on
tro
ller
Ext
ern
al
co
mm
an
d
co
ntr
ol
Ce
ntr
al
rem
ote
c
on
tro
l
Inte
rlo
ck
co
ntr
ol
PE
fin
*Temperature-sensor on indoor unit must be used when the air c onditioner is c ontrolled from another room. **Wireless remote c ontroller does not have a temperature-sensor.
Note : Anec hoic c hamber c onvers ion value, measured ac c ording to J IS parameters and
41/35dB(A)FVY71LA
High Low
Sound level
dB(A)
-
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
2827
FDMG71A
Freedom of layout Quiet operation
Middle static pressure type is available in a larger than standard space
Duct connection is simpler with standard rear intake chambers
The duct system allows the efficient location of discharge outlets in accordance with the room layout Indoor unit High
FDMG125A 45FDMG100A 44
42LOW38
FDMG140AFDMG180A
4647
3736
3637
FDYM03FA
FDYM05FA 44FDYM04FA 39
39
FDYM06FA 46
Switchable fan speed: High/Low
Programme "Dry"Dehumidification is microprocessor controlled to prevent abrupt and un-comfortable changes in air temperature.
Low gas pressure detectionInsufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure.
Compact, 295 mm high design makes installation possible where the ceiling space is limited (For FDYM)
Air c onditioner295 mm
Ordinary duc t(proc ured loc ally)
Ordinary duc t(proc ured loc ally)
Air blow Air intake
305 mm or more
See pages 31–32 for details of the Multi Series.
Supports simultaneous running of the twin and triple multi operations.Twin Multi Operation Triple Multi Operation
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Ventilation grille
Door-installedventilation grille
Ventilation grille
Wall-installedventilation grille
Under-door c utout
Under-door cutoutWhen air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Ventilates air through the partitioning wall. (S ee right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
FDYM03FA
FDMG100A
39dB(A)FDYM03FA
(220V)
High
Sound level
Guide Line upP. 3–10
Outdoor unitsP. 33–34
OptionsP. 59
Outer dimension drawingsP. 64, 65
Remote controllersP. 35–36
Standard specificationsP. 43, 48, 53, 56
Unit can be mounted in the ceiling and air can be delivered freely by duct.
DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE
FDMG/FDYMFDMG71AV1–180AV1FDYM03FAV1–06FAV1
Cooling only
FDYM03FAV1–06FAV1Heat pump
Comfort Work & Servicing Control features OthersFeatures (Features are explained on P. 37–38.)
*3
*3
*3
*3
*2
*1
Feature
Model
Heat pump
Cooling only
FDMGFDYM
*1Applic able to R 71LU– R 140LU outdoor units (for temp. down to – 15°C ) (An option is required.)*2Applic able to R Y71LU– R Y140LU outdoor units (for temp. down to – 5°C ) and R Y200LU– R Y250LU outdoor units (for temp. down to – 0°C )*3Applic able to R (Y)71LU– 140LU outdoor units
Sw
itch
ab
le
fan
sp
ee
d
Pro
gra
mm
e
"Dry
"
Ho
t st
art
Tim
er
sele
cto
r
Pre
c
ha
rge
d
for
up
to
3
0
m
Lo
w
ga
s p
ress
ure
d
ete
ctio
n
Em
erg
en
cy
op
era
tion
Se
lf-d
iag
no
sis
fun
ctio
n
Co
ntr
ol
by
2
rem
ote
c
on
tro
llers
Au
to-r
est
art
Ad
just
ab
le
ext
ern
al
sta
tic
pre
ssu
re
Gro
up
cont
rol
by
1 re
mot
e co
ntro
ller
Ext
ern
al
co
mm
an
d
co
ntr
ol
Ce
ntr
al
rem
ote
c
on
tro
l
Inte
rlo
ck
co
ntr
ol
PE
fin
Twin
an
d
trip
le
mul
ti op
erat
ion
Au
tom
atic
c
oo
l/h
ea
tc
ha
ng
e
-ove
r
Ye
ar-
rou
nd
c
oo
ling
a
pp
lica
ble
BRC4C64
Wired LCD remote controller Wireless LCD remote controller
Wireless remote c ontroller and s ignal rec eiver unit are sold as a set.
Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally.
Accessory required for indoor unit (option)
BRC1C61 Cooling only
BRC4C62Heat pump
Signal receiver unit(Separate type)
For FDYM
For FDMGDigital remote controller
KRC47-2AKRC47-4A
Remote controller
Note : Anec hoic c hamber c onvers ion value, measured ac c ording to J IS parameters and
dB(A) (220V)
KRC47-1A
-
3029
Supports simultaneous running of the triple and double twin multi operations.
Triple Multi Operation Double twin Multi Operation
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
Durable
Quiet operationSmall, lightweight, and easy-to-install outdoor unit.
Compact
51dB(A)FDY06KA
Sound level
Highly durable outdoor unit has PE fins for improved resistance to salt corrosion and atmospheric pollution.
DurableMany options are available for use with large-scale and advanced-function centrally controlled systems
Central controlQuiet operation
S uc tion c hamber
Air filter[Duc t c onnec tion]
To prevent increased operation sound, avoid installing the air suction grille directly below the suction chamber.
FDYB50KA FDY06KA
38dB(A)FDYB50KA
LOW
Sound level
Ideal for quiet, beautiful living spacesSuitable for condominiums and apartments, houses and hotels
Recommended for spacious and large-volume areas because of its flexible installationSuitable for large stores, factories, and other large areas, and for use with housing ducts in homes
Digital remote controller Remote controller
High
See pages 31–32 for details of the Multi Series.
Guide Line upP. 3–10
Outdoor unitsP. 33–34
OptionsP. 59
Outer dimension drawingsP. 64
Remote controllersP. 35–36
Standard specificationsP. 42, 52, 56
GuideLine upP. 3–4, 7–8Outdoor unitsP. 33–34
OptionsP. 59Outer dimension drawingsP. 65–67
Remote controllersP. 35–36Standard specificationsP. 44, 45, 53
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Ventilation grille
Door-installedventilation grille
Ventilation grille
Wall-installedventilation grille
Under-door c utout
Under-door cutoutWhen air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicate ventilation grilles should be installed on the partitioning wall or under the door between the rooms.
Ventilates air through the partitioning wall. (S ee right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
Cooling only
Heat pump
KRC47-2AKRC47-4A
KRC47-1A
Remote controllerCooling only
KRC47-3A
Wired LCD remote controller Wireless LCD remote controller
Wireless remote c ontroller and s ignal rec eiver unit are sold as a set.
Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally.
Accessory required for indoor unit (option)
BRC1C61
BRC4C62
Heat pumpWired LCD remote controller Wireless LCD remote controller
Wireless remote c ontroller and s ignal rec eiver unit are sold as a set.
Note: R emote c ontroller c able not inc luded. C ables must be proc ured loc ally.
Accessory required for indoor unit (option)
BRC1C61
BRC4C62
DUCT CONNECTIONLOW STATIC PRESSURE TYPE
FDBG/FDYBFDBG25AVE–71AVECooling onlyFDYB35KAVE–71KAVEHeat pump
DUCT CONNECTIONHIGH STATIC PRESSURE TYPE
FD(Y)FD03KY1–20KY1Cooling onlyFDY06KAY1–20KAY1Heat pump
*2 *3
*3
*2*4 *4*1
Features (Features are explained on P. 37–38.)Feature
Model
Heat pumpCooling only
*1Applic able to R Y140LU outdoor units (for temp. down to – 5°C ) and R Y200LU– R Y250LU outdoor units (for temp. down to – 0°C )*2Applic able to R (Y)140LU outdoor units*3R equired to c hange the pulley*4FDY06-10 only
Comfort Work & Servicing Control features Others
Ho
t st
art
Tim
er
sele
cto
r
Pre
c
ha
rge
d
for
up
to
3
0
m
Lo
w
ga
s p
ress
ure
d
ete
ctio
n
Em
erg
en
cy
op
era
tion
Se
lf-d
iag
no
sis
fun
ctio
n
Co
ntr
ol
by
2
rem
ote
c
on
tro
llers
Au
to-r
est
art
Ad
just
ab
le
ext
ern
al
sta
tic
pre
ssu
re
Gro
up
cont
rol
by
1 re
mot
e co
ntro
ller
Ext
ern
al
co
mm
an
d
co
ntr
ol
Ce
ntr
al
rem
ote
c
on
tro
l
Inte
rlo
ck
co
ntr
ol
PE
fin
Au
tom
atic
c
oo
l/h
ea
tc
ha
ng
e
-ove
r
Ye
ar-
rou
nd
c
oo
ling
a
pp
lica
ble
Comfort Work & Servicing Control features Others
*2*2*1
Features (Features are explained on P. 37–38.)Feature
Model
Heat pumpCooling only *1Applic able to R Y71LU outdoor units (for temp. down to – 5°C )
and R Y200LU– R Y250LU outdoor units (for temp. down to – 0°C )*2Applic able to R Y71LU outdoor units
Sw
itch
ab
le
fan
sp
ee
d
Pro
gra
mm
e
"Dry
"
Ho
t st
art
Tim
er
sele
cto
r
Pre
c
ha
rge
d
for
up
to
3
0
m
Lo
w
ga
s p
ress
ure
d
ete
ctio
n
Em
erg
en
cy
op
era
tion
Se
lf-d
iag
no
sis
fun
ctio
n
Co
ntr
ol
by
2
rem
ote
c
on
tro
llers
Au
to-r
est
art
Ad
just
ab
le
ext
ern
al
sta
tic
pre
ssu
re
Gro
up
cont
rol
by
1 re
mot
e co
ntro
ller
Ext
ern
al
co
mm
an
d
co
ntr
ol
Ce
ntr
al
rem
ote
c
on
tro
l
Inte
rlo
ck
co
ntr
ol
PE
fin
Trip
le
and
d
oub
le
twin
m
ulti
oper
atio
n
Au
tom
atic
c
oo
l/h
ea
tc
ha
ng
e
-ove
r
Ye
ar-
rou
nd
c
oo
ling
a
pp
lica
ble
(220V)
Signal receiver unit(Separate type)
Signal receiver unit(Separate type)
Note : Anec hoic c hamber c onvers ion value, measured ac c ording to J IS parameters and c riteria.
FDBG60AVE 42 39Indoor unit High Low
dB(A)
-
MULTI SERIES
MULTI SERIESTwin, Triple, and Double Twin Multi-Operation
Simultaneous operation system
Note: This type of system does not allow individual control or independent operation of indoor units. It is not the best choice for large rooms with partitions.
In a single-floor restaurant, for example, positioning 4 units at strategic locations realises comfortable airflow that reaches every inch of the room.
Double Twin Multi operation
4 indoor units can be run simultaneously with a single outdoor unit.
Improved comfort level and space-saving for outdoor unit installation
Required about 40% less installation space for outdoor unit
4 indoor units distribute comfortable airflow throughout the room. Simultaneous operation of four indoor units can be controlled from a single remote controller. Requires a single refrigerant piping system.
Triple Multi operation Twin Multi operation
Indoor units include ceiling mounted cassette type, ceiling suspended type, and duct connection middle and low static pressure type.
Before5 HP x 2 units
R(Y)125KU x 2 units
10 HP double twin multi operation
R(Y)200KU or R(Y)250KU x 1 unit
New
Before New
Installing multiple units is economical and realises comfortLower cost of installation than for individual pair typeReduced installation space for outdoor unitsEnhanced comfort from distributed indoor units
Branch piping kitBranch piping kit
Branch piping kitBranch piping kit
Branch piping kit
In large interior spaces a single indoor unit may not be able to provide uniform comfort. Installation of 2 to 4 units, can provide an effective solution.
Dea
d zo
ne
Dea
d zo
ne
31
500 mm
300 mm
300 mm
1000 mm
Simultaneous operation system
Remote controllers for the Multi Series
Simultaneously operates 2 to 4 indoor units using a single outdoor unit.
32
(Branch piping kits are sold separately. Please use the model indicated on page 59) Refrigerant piping uses terminal branching to facilitate installation.
Main pipeRemote controller
Outdoor unit
Branch piping kit
Sub unit Main
unit
L
L2L1
Piping Guideline
Main pipeRemote controller
Outdoor unit
Branch piping kit
Sub unit Main
unit
L
L3L2
Sub unit
L1
Sub unit Sub
unit
Main pipeRemote controller
Outdoor unit
Branch piping kit
Sub unit Main
unit
L
L6L5L4
L3
L1
L2
Max. branch piping length
*1 Max. (L1, L2) means maximum length out of L1 and L2. *2 Min. (L1, L2) means minimum length out of L1 and L2.
Max. (L1, L2)*1 20 m
Simultaneous operation system
Max. level difference between outdoor unit and indoor units
Max. (L1, L2 , L3) 20 m Max. (L1, L2) Max. (L3, L4, L5, L6) 20 m
30 m 30 m 30 m
Max. level difference between indoor units 0.5 m 0.5 m 0.5 m
Max. piping length L Max. (L1, L2) 50 m L Max. (L1, L2, L3) 50 m L Max. (L1, L2) Max. (L3, L4, L5, L6) 50 m
Max. branch pipe length difference Max. (L1, L2) Min. (L1, L2)*2 10 m L2 L1 10 m L4 L3 10 m L6 L5 10 m
(L2 L6) (L1 L3) 10 mMax. (L1, L2, L3) Min. (L1, L2, L3) 10 m
Double Twin Multi OperationTwin Multi Operation
Twin Multi Operation Triple Multi Operation Double Twin Multi Operation
Triple Multi Operation
In case of L1 L2, L3 L4, L5 L6
Guide Line upP. 5–6, 9–10
Outdoor unitsP. 33–34
OptionsP. 57–59
Outer dimension drawingsP. 60–74
Remote controllersP. 35–36
Standard specificationsP. 46–48, 54–56
(For Triple Multi)(For Twin Multi) (For Double Twin Multi)
(Option)
Connect the wired remote controller to turn an indoor unit into the master unit.
Install the signal receiver unit (part of the optional wireless remote controller) to turn an indoor unit into the master unit.
Wired remote controller has a temperature-sensor. Depending on the installation conditions, select and set the temperature-sensor of a selected indoor unit or the temperature-sensor of the remote controller.
Because the wireless remote controller does not have a temperature-sensor, select the temperature-sensor of the indoor master unit.
Wired LCD remote controller
BRC1C61
Wireless LCD remote controller
CEILING MOUNTED CASSETTE TYPE
A single remote controller controls simultaneous operation of multiple indoor units.
Supports Two selectable temperature-sensor functions.
Note: An indoor unit's temperature-sensor must be used when the air conditioners are controlled from another room.
INDOOR UNIT(Option)
CEILING SUSPENDED TYPE
DUCT CONNECTIONLOW STATIC PRESSURE TYPE
Note: Selectable temperature sensing is available with ceiling-mounted cassette and ceiling-suspended models, but not with middle static-pressure models.
DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE
BRC7C612WCooling only BRC7C613W
Heat pump
BRC7E63WCooling only BRC7EA66
Heat pump
Heat pump BRC4C62
BRC4C62Cooling only BRC4C64
Heat pump
-
Fully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence.
Fitted with wide inlet fan (Applies to R(Y)71LU–140LU)
Compactly designed outdoor unit with interior layout optimised for the smooth airflow.
The design curved Super Aero Grille restricts the spread of exhaust gas and fits in the same space as conventional outdoor units.
Slim and low-profile design outdoor units (Applies to R(Y)71LU–140LU)
The light weight makes delivery and installation easier.
Reduced weight (Applies to R(Y)71LU-125LU)
To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air.
Fitted with Super Aero Grille(Applies to R(Y)71LU–140LU)
Smooth running, minimal vibration, low operating sound.
Equipped with scroll compressor for quiet operation (Applies to R(Y)125LU and 140LU)
Operation soundWide inlet fan (Applies to R(Y)71LU–140LU)
C o m pa c t
Compact unit provides quiet operation.
Defrost control delivers powerful heating in extremely cold climates(Applies to RY71LU–140LU) (Heat pump only)
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.(Applies to R(Y)71LU–140LU)
I n s t a l la t io n a n d m a in t e n a n c e
Pre charged for up to 30 metres
Heat pumpOutdoor unit Sound level (cool/heating)
dB(A)
RY71LU 48/49RY100LU 49/52RY125LU 49/52RY140LU 54/56
Max
. poi
nt o
f in
tegr
al c
apac
ity
Difference between indoor heat exchange temperature and intake air temperature ( T)
Integral heating capacity
Def
rost
and
hot
sta
rt
Defrost begins in this area
00
5
10
15
20
25°C
10 20 30 40 50 60 70 80Elapses operation time (min.)
Defrost operation complete(heating operation restart)
Defrost monitoring start (monitors to maximum point)
Integral heating capacity and temperature difference (actual measurement when outdoor temperature is -1.5°C)
Cooling onlyOutdoor unit Sound level
R71LU 48R100LU 49R125LU 49R140LU 54
OUTDOOR UNIT
Allowed refrigerant pipe length and level difference
Max. length Max. leveldifference
Pre charged*1
25 m10 mR25J20 m10 mRY35F25 m10 mR35J
30 mRY71LUR71LU
30 mRY100LUR100LU50 m
(Equivalent length 70 m)
50 m(Equivalent length 70 m)
10 mRY50GAR50G 30 m
5 mRY60GAR60G 30 m
50 m(Equivalent length 70 m)
50 m(Equivalent length 70 m)
30 mRY125LUR125LU
30 mRY140LUR140LURG71ARA140ARG180A
Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.
P o w e r fu lUses "Receiver" to enhance refrigerant control (Applies to R(Y)71LU–140LU)
Instead of the using an accumulator to ab-sorb excess refrigerant, Daikin outdoor units have a receiver in the piping located away from the compressor. By preventing the return of liquid to the compressor, the receiver enhances reliability.
Cooling is efficient even in winter when indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers.
Suited for year-round cooling applications
RY200KU and250KU can adapt up to 0°C.
Also adapts to year-round cooling
A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified.
4-direction piping offers greater layout freedom(Applies to R(Y)71LU–140LU)
Facilitates pump down (Refrigerant recovery function)
Effective gas monitoring reduces the labor required for operation, maintenance, and repairs.
Piping can be run from the front, bottom, right or rear surface according to how the unit is installed.
Low gas level detection function(Applies to R(Y)71LU–140LU)
• Heat pump/RY71–140LU: possible up to -5°C• Cooling only/R71–140LU: possible up to -15°C• The year-round cooling kit is required as option.
OUTDOOR UNIT
(Applies to all outdoor units)
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
D u r a bi l i t yHeat exchange fins provided with anti-corrosion treatment
ConstructionNon-treated fin
PE fin
Aluminium
AluminiumC orros ion res is tantac rylic res in
Hydrophilic film
Common width and depth make series installation easy.
200 and 250 class models canbe combined for centralised, horizontal-series installation
R(Y)250KU
1280 mm
R(Y)200KU
1280 mm
R(Y)200KU
1280 mm
690 mm
Max. length Max. leveldifference
Pre charged*1
50 m(Equivalent length 70 m) 30 m
50 m(Equivalent length 70 m) 30 m
5 mR(Y)200KU
5 mR(Y)250KU
Piping can be drawn out from three directions - front, left side, or below.
33 34
Flexible design for large roomor multi-use
Q u ie t O pe r a t io n
(Heat pump only)
R(Y)71LU R(Y)100LU R(Y)125LU R(Y)140LU
500
50
(mm)
conventional
108 kgRY100KUV1
New
89 kgRY100LUV1
Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.
Allowed refrigerant pipe length and level difference
To optimise heating performance, by monitoring the difference in air temperature in the indoor/outdoor heat exchanger and the intake air temperature, the system accurately adjusts to provide the best operating parameters. This enables defrost mode to be initiated and so minimise indoor declines in temperature caused by frost. For example, if the outdoor airtemperature falls to -1.5°C, the integrated heating capacity is raised about 20%.
RU08/10KU models are factory shipped with refrigerant charged for 5 m of piping.RU08/10K models are factory shipped with no refrigerant charged.
RU08/10K models are available in two type depending on installation conditions
15 m15 m15 m
30 m
30 m
15 m
15 m
30 m
30 m
50 m(Equivalent length 70 m)5 m
R100FUR125FU 30 m
50 m(Equivalent length 70 m)5 m 30 m
Note : Anec hoic c hamber c onvers ion value, measured ac c ording to J IS parameters and
-
LCD REMOTE CONTROLLER
Remote controller options are shown on the page introducing each indoor unit model.
Wireless LCD remote controllerThe wireless remote controller is supplied in a set with a signal receiver.Shape of signal receiver unit differs according to the indoor unit.
Note: The s ignal rec eiver unit shown in the photograph is for mounting ins ide the dec oration panel of the c eiling mounted c assette type.
N o n -po la r , do u ble -c o r e c o n n e c t io n s pe c i f ic a t io n s s im pl i fy w ir in g
S k y A ir s h a r e s c o m m o n c o n t r o l w it h H R V (h e a t r e c la im v e n t i la t io n ) a n d t h e o t h e r D a ik in a i r -c o n dit io n in g u n it s , t h u s s im pl i fy in g in t e r lo c k in g o pe r a t io n s .
Easily adaptable to large-scale, high-function, centralised remote control systems.Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.
Optional adaptor for external commands or remote control of external equipment has been standardised to one type.
F a c i l i t a t e s m a in t e n a n c e a n d r e pa ir
Non-polar, double-core remote controller wire prevents wiring mistakes. signal receiver unit (or decoration panel) of wireless type is also easy to connect.
All initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted units can be remotely set without having to use stepladder access for manual setting.Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically).Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction.
Signal receiver unit (For ceiling mounted cassette type)
Wireless remote controller
Note: When a wireless remote c ontroller is used, remote c ontrol by two remote c ontrollers is not poss ible.
L C D pa n e l s h o w s o pe r a t in g s t a t u s in le t t e r s , n u m be r s , a n d m o t io n .Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
(Not available for ceiling mounted built-in type and duct connection type )Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Programming time display Operation start and stop time can be set for individual timers up to 72 hours. The liquid crystal display also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
LCD REMOTECONTROLLERS
signal receiver mounted type
For easier operation, louver switches, which are frequently used, have been made larger.Oil-resistant plastic casing. Only 17 mm thick. Can be installed either recessed or exposed.
W ir e d r e m o t e c o n t r o l le r h a s bu i l t -in t e m pe r a t u r e -s e n s o r (Applies to wired remote controllers)
Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.)Note: The indoor unit’s temperature-sensor is specified at the time of
shipment. Temperature sensing with the wired remote controller is not available with the ceiling mounted cassette corner, ceiling-mounted built-in, and duct connection type.
Easier to read because LCD screen is larger.
35 36
Wired LCD remote controller
*1. When the auto-swing function is not available, the message, THIS FUNCTION IS NOT AVAILABLE is displayed when the wind direction adjustment button is pressed.*2. Applicable to only heat pump type.
C e n t r a l r e m o t e c o n t r o l le r
Easily adaptable to large-scale, high-function, centralised remote control system.
Centralised control, with setting as simple as it is with a standardremote controller, of up to 64 groups (1,024 indoor units) is possible.
DCS302CA61 (Option)
With its high functionality, the full color “all-in-one” graphic controller facilitates management of Skyair System in a variety of ways.
DCS601C51 (Option)U n if ie d o n /o ff c o n t r o l le r
Centralised control of on/off by group or all at once for up to 256 indoor units.
DCS301BA61 (Option)S c h e du le t im e r
Unified control of weekly schedule for up to 1,024 indoor units.
DST301BA61 (Option)
Indoor units applicable for the remote controller
S im ple s y s t e m pr o v ide s a d iv e r s e a s s o r t m e n t o f c o n t r o l m o de s .
Interface adaptorfor SkyAir series
Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin VRV system.Necessary for interface adaptor for SkyAir series with the central remote control units shown at above.
DTA102A52 (Option)
Central control adaptor kit *2
DTA107A55 (Option)
Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time.
BRC1C61
CEILING MOUNTED CASSETTE TYPECEILING SUSPENDED TYPECEILING SUSPENDED CASSETTE TYPECEILING MOUNTED CASSETTE CORNER TYPEWALL MOUNTED TYPE CEILING MOUNTED BUILT-IN TYPE*1DUCT CONNECTION LOW STATIC PRESSURE TYPE *2DUCT CONNECTION MIDDLE STATIC PRESSURE TYPEDUCT CONNECTION HIGH STATIC PRESSURE TYPE *2
*1. When the auto-swing function is not available, the message, THIS FUNCTION IS NOT AVAILABLE is displayed when the wind direction adjustment button is pressed.*2. Applicable to only heat pump type.•Standard remote controller (BRC1C61) is not required.•If the BRC1D61 is connected to the centralised remote controller, the schedule function is not available.
Indoor units applicable for the remote controller
BRC1D61
CEILING MOUNTED CASSETTE TYPECEILING SUSPENDED TYPECEILING SUSPENDED CASSETTE TYPECEILING MOUNTED CASSETTE CORNER TYPEWALL MOUNTED TYPE CEILING MOUNTED BUILT-IN TYPE*1DUCT CONNECTION LOW STATIC PRESSURE TYPE *2DUCT CONNECTION MIDDLE STATIC PRESSURE TYPEDUCT CONNECTION HIGH STATIC PRESSURE TYPE *2
BRC1C61
24-hour clock function (1-hour backup for power failures)Programming function for each day of week.Scheduling possible of start/stop and temperature limit (5 settings/day)Programming can be enabled or disabled. Copy function for programmed schedules.
Remote control is equipped with weekly timer function.Wired LCD remote controller with weekly schedule timer
BRC1D61
Indoor units applicable for the remote controller
Signal receiver unit is contained inside decoration panel or indoor unit
CEILING MOUNTED CASSETTE TYPE
DUCT CONNECTION LOW STATIC PRESSURE TYPEDUCT CONNECTION MIDDLE STATIC PRESSURE TYPEDUCT CONNECTION HIGH STATIC PRESSURE TYPE
WALL MOUNTED TYPE
CEILING SUSPENDED CASSETTE TYPE
BRC7C612W BRC7C613W
BRC7E63W BRC7EA66
BRC7C528W BRC7C529W
BRC7EA618 BRC7E619BRC7C610W
FAY71LFAY100FA BRC7C611W
BRC4C62
BRC4C62 BRC4C64
BRC4C62
CEILING SUSPENDED TYPE
Heat pump Cooling only
Necessary optional accessory
Control by 1remote controller
Control pattern Wired remote controller Wireless remote controller
Control by 2remote controllers
Group control
Control by external command
Centralised remotecontrol
Interlock controlwith HRV
(Basic system)
Link by remote controller group control.
Zone link control by centralised control.
For control from 2 locations such as in room and control room, exits, etc.
For simultaneous control of up to 16 indoor units.
Centralised control of up to 64 indoor groups from remote locationup to 1 kilometer away.
C ontrol by 1 wireless remote c ontroller and 1 wired remotec ontroller (S ee note 1)
S ignal rec eiver unit installed on indoor unit
Automatic address setting func tion
S ignal rec eiver unit installed on 1 indoor unit
S ignal rec eiver unit installed on indoor unit
Optional wiring adaptor for elec tric al appendic es is nec essary
Optional S kyAir series interfac e adaptor required. *1
C an be operated s imultaneously by remote c ontroller (set by ventilation mode)
HR V for indoor units within a zone are operated by interloc kingOptional interfac e adaptor for S kyAir seriesis nec essary *1
(C ommand from outs ide)
C entral remote c ontroller (option)
C entral remote c ontroller (option)
HR V
Non-polar, double-c ore (max. wiring length 500 m)
C onnec ts 2 wired remote c ontrollers
Automatic address setting func tion
Optional S kyAir series interfac e adaptor required. *1
C an be operated s imultaneously or independently by remote c ontroller (set by ventilation mode)
HR V for indoor units within a zone are operated by interloc kingC an also be operated independently by remote c ontroller.Optional interfac e adaptor for S kyAir seriesis nec essary *1
(C ommand from outs ide)
C entral remote c ontroller (option)
C entral remote c ontroller (option)
HR V
HR V HR V
Note : DIII-net adaptor function is standard equipment for the FAY71L.
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room.
*Please refer to the page 59 for the details.
(for FD series)
*2.The central control adaptor kit for FDB series can be made to order.
*1. DIII-net adaptor function is standard equipment for the FAY71L.
Optional wiring adaptor for elec tric al appendic es is nec essary
Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units.
-
C o m f o r t
A u t o -s w in g
Air discharge direction angle can be set (fixed setting)
D r a ft pr e v e n t io n fu n c t io n (heating)
You can increase fan speed approximately 10% higher than the "high" setting.
M o u l d p r e v e n t i o n
H ig h fa n s pe e d m o de
Dehumidification is microprocessor controlled to prevent uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling.
P r o g r a m m e " D r y "
Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.
H ig h -c e i l in g a ppl ic a t io n
Uncomfortable cold air draft is not discharged when heating operation starts or when switching to heat after defrosting.
H o t s t a r t (after defrost)
Efficient cooling even in winter when indoor temperatures are higher than those outside, such as in underground pub-lic spaces or offices with many computers.
Y e a r -r o u n d c o o l in g a ppl ic a ble
Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.
T im e r s e le c t o r
Sanitary filter has mould-resistant treatment.M o u ld-r e s is t a n t t r e a t m e n t fo r f i l t e r
Mould-proofing maintains hygiene by preventing growth in highly humid conditions.
M o u ld-pr o o f in g dr a in pa nO p t i o n s
Two types are available: 65% and 90% colorimetry.H ig h -e ff ic ie n c y f i l t e r u n it
Requires no maintenance for about 4 years* (10,000 h) in stores and offices. * For dust concentration of 0.15 mg/m3
U lt r a lo n g -l i fe f i l t e r
You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.
F r e s h -a ir in t a k e k i t
W o r k a n d S e r v i c i n g
Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.
D r a in pu m p m e c h a n is m
Maintenance is not required for one year (two years when a ceiling mounted cassette type is used).
L o n g -l i fe f i l t e r
Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.
C e i l in g s o i l in g pr e v e n t io n fu n c t io n
If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.
P r e c h a r g e d fo r u p t o 3 0 m e t r e s
If there is a malfunction elsewhere in the system, the fan or compressor can still be operated.
E m e r g e n c y o pe r a t io n
The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates.
S e l f d ia g n o s is fu n c t io n
C o n t r o l f e a t u r e s
If there is a power outage while the equipment is op-erating, operations will restart in the same mode as before the power cut when electricity is restored.
A u t o -r e s t a r t
A u t o c o o l/h e a t c h a n g e -o v e r
Using 2 remote controllers you can operate the equipment locally or from a remote location.
C o n t r o l by 2 r e m o t e c o n t r o l le r s
Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.
You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.)
C o n t r o l by 1 r e m o t e c o n t r o l le r
E x t e r n a l c o m m a n d c o n t r o l
Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away.
C e n t r a l r e m o t e c o n t r o l
Enables interlocking control with external equipment such as heat reclaim ventilation (HRV).
I n t e r lo c k c o n t r o l
Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner.
To prevent cold air drafts, automatically adjusts airflow to horizontal vector when heating initially starts or when the thermostat turns off.
Detects difference in preset temperature and actual room temperature and automatically switches to cooling or heating accordingly.
Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room.
(1) Air direction in standard position
(2) Air direction in draft prevention position
(3) Air direction in ceiling soiling prevention position
You can freely set 3 air discharge positions by remote controller.
S w in g pa t t e r n s e le c t io n (draft prevention, standard, ceiling soiling prevention)
High setting provides maximum reach while low setting minimises drafts.
S w it c h a ble fa n s pe e d
O t h e r s
To achieve increased durability by improved resistance to salt corro-sion and atmospheric pollution, coated PE fins (with special acryl pre-treatment) are used for the heat exchanger of the outdoor unit.In high corrosive areas, regular maintenance needs to be carried out.
P E f in
Simultaneously operates 2–4 indoor units with a single outdoor unit.
T w in / t r iple / do u ble t w in m u lt i o pe r a t io n
37 38
Use the temperature-sensor in the indoor unit when controlling air conditioning from another room.
T w o s e le c t a ble t e m pe r a t u r e -s e n s o r s
Temperature-sensors are included in the indoor unit and op-tional wired remote controller. Temperature sensing closer to target area is possible to further
Note: Wireless remote controllers have no temperature-sensor.
(Heat pump only)
• Heat pump/RY71—140LU: possible up to -5°C• Cooling only/R71—140LU: possible up to -15°C• The year-round cooling kit is required as option.
Applicable for ceiling mounted cassette type and ceiling mounted cassette corner type.
Abundance of functions that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Applicable for wall mounted type
Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.
The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.
F i l t e r s ig n
L o w g a s pr e s s u r e de t e c t io n
Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by microprocessor to maintain proper gas pressure.Reliability is assured and maintenance and inspection can be carried out more quickly.
(Horizontal air disc harge)
(Applies to R(Y)71LU–140LU)
*Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending.
Note:
-
15 30
39 40
CEILING MOUNTED CASSETTE CORNER TYPE
White
35
12,100/11,6003.54/3.4
FHK35FV1
R35GV1
3,040/2,930
1.41/1.40
12423
39/33215X1,110X710
30
Ivory white Hermetically sealed rotary type
1.11.10 (Charged for 10 m)
48540X750X270
37
45
17,700/17,5005.19/5.1
FHK45FV1
R50GV1
4,460/4,400
2.25/2.24
12423
39/34215X1,110X710
31
1.71.20 (Charged for 10 m)
49540X750X270
42
60
22,760/22,2006.6/6.5
FHK60FV1
R60GV1
5,690/5,600
2.76/2.74 3.07/3.07 (V1)3.05/3.05 (Y1)
17600
41/36215X1,310X710
3370X1,240X800
8.5
70X1,240X800
8.5
70X1,440X800
9.5
2.21.50 (Charged for 5 m)
54685X800X300
61
71
26,600/26,2007.8/7.7
FHYK71FJV1R71LUV1R71LUY1
6,700/6,600
17600
41/36215X1,310X710
3370X1,440X800
9.5
2.24Hermetically sealed scroll type
2.8 (Charged for 30 m)48
770X900X32072 (V1), 71 (Y1)
CEILING MOUNTED CASSETTE TYPE
White
35
12,100/11,6003.54/3.4
FH35BVE
R35GV1
3,040/2,930
13458
37/32195X960X680
23
Ivory white Hermetically sealed rotary type Hermetically sealed scroll type
1.11.10
48540X750X270
37
50
17,700/17,5005.19/5.1
FH50BVE
R50GV1
4,460/4,400
13458
38/33195X960X680
24
1.71.20
49540X750X270
42
60
22,760/22,2006.6/6.5
FH60BVE
R60GV1 R125LUY1
5,690/5,600
1.51/1.50 2.16/2.15 2.80/2.78 4.92/4.92
16564
38/33195X1,160X680
26
2.21.50
54685X800X300
61
71
26,600/26,2007.8/7.7
FHY71BVER71LUV1R71LUY1
6,700/6,600
17600
39/35195X1,160X680
27
2.242.8
48770X900X320
72 (V1), 71 (Y1)
100
36,100/35,70010.6/10.5
FHY100BVER100LUV1R100LUY1
9,100/9,000
24847
42/37195X1,400X680
32
3.003.7
491,170X900X32087 (V1), 84 (Y1)
125
44,500/43,60013.0/12.8
FHY125BVE
11,200/11,000
301,05944/39
195X1,590X68035
3.753.7
491,170X900X320
98
White
35
12,100/11,9003.54/3.5
FHC35KVE
R35GV1
3,040/3,010
1.20/1.20
14494
230X840X840
24
Ivory white Hermetically sealed scroll typeHermetically sealed rotary type
1.11.10
48540X750X270
37
50
18,200/18,1005.34/5.3
FHC50KVE
R50GV1
4,590/4,560
2.02/2.01
15529
230X840X840
24
1.71.20
49540X750X270
42
60
22,000/21,8006.44/6.4
FHC60KVE
R60GV1 R125LUY1
5,540/5,500
2.45/2.44 4.96/4.96 5.02/5.02
19670
230X840X840
24
2.21.50
54685X800X300
61
71
26,600/26,2007.8/7.7
FHYC71KVER71LUV1R71LUY1
6,700/6,6003.07/3.07 (V1)3.05/3.05 (Y1)
4.01/4.01 (V1)3.96/3.96 (Y1)
19670
230X840X840
24
2.242.8
48770X900X320
72 (V1), 71 (Y1)
100
36,100/35,70010.6/10.5
FHYC100KVER100LUV1R100LUY1
9,100/9,000
28988
288X840X840
28
3.003.7
491,170X900X32087 (V1), 84 (Y1)
125
44,500/43,60013.0/12.8
FHYC125KVE
R140LUY1
140FHYC140KVE
11,200/11,000
331,16442/3633/29 33/29 35/30 35/30 39/34
288X840X84040X950X950 40X950X950 40X950X950 40X950X950 40X950X950 40X950X950
285 5 5 5 5 5
3.753.7
49 541,170X900X320
98
Both liquid and gas piping
CEILING SUSPENDED TYPE
Both liquid and gas pipingBoth liquid and gas piping
49,400/48,40014.5/14.2
12,500/12,200
351,23544/37
288X840X84040X950X950
285
4.504.1
1,345X900X320109
----------
19.4 to 54 19.4 to 4619.4 to 46
19.4 to 5419.4 to 46 19.4 to 46
21 to 46, -15 to 46 3 (Option installed)
14 to 23 14 to 25
21 to 46, -15 to 46 3 (Option installed)
14 to 25
21 to 46-15 to 46 3 (Option installed)
14 to 25
----------
3015
14 to 23
3015
14 to 23
50 (equivalent length 70 m)25 30
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoorunit
Indoor unit
Outdoor unit
Dimensions(HXWXD)
Colour
mmmm
Sound level (H/L) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weight kgkgUnit
Decoration panel
Airflow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Certified operation range
Max. interunit piping length mmMax. installation level difference
50 (equivalent length 70 m)3025
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
ModelName
Indoorunit
Indoor unit
Outdoor unit
Sound level (H/L) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Machine weight kg
Certified operation range °CDB
Certified operation range °CWB
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Airflow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Dimensions (HXWXD)
Colour
mm
Max. interunit piping length mmMax. installation level difference
50 (equivalent length 70 m)25 30
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoorunit
Indoor unit
Outdoor unit
Dimensions(HXWXD)
Colour
mmmm
Sound level (H/L) 2 dB(A)
Refrigerant charge (R-22)Sound level 2
kgdB(A)
Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)
Max. installation level differenceHeat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weight kgkgUnit
Decoration panel
Airflow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Certified operation range
Max. interunit piping length mm
CEILING SUSPENDED CASSETTE TYPE
White
Ivory white Hermetically sealed scroll type
R125LUY1
71
26,600/26,2007.8/7.7
FUY71FJV1R71LUV1R71LUY1
6,700/6,600
40/35
19670
165X895X89525
2.242.8 (Charged for 30 m)
48770X900X320
72 (V1), 71 (Y1)
100
36,100/35,70010.6/10.5
FUY100FJV1R100LUV1R100LUY1
9,100/9,000
43/381,023
29
230X895X89531
3.003.7 (Charged for 30 m)
491,170X900X32087 (V1), 84 (Y1)
125
44,500/43,60013.0/12.8
FUY125FJV1
11,200/11,000
4.97/4.97
44/391,129
32
230X895X89531
3.753.7 (Charged for 30 m)
491,170X900X320
98
30
21 to 46, -15 to 46 3 (Option installed)
14 to 25
50 (equivalent length 70 m)
3.08/3.08 (V1)3.06/3.06 (Y1)
4.07/4.07 (V1)4.02/4.02 (Y1)
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
ModelName
Indoorunit
Indoor unit
Outdoor unit
Sound level (H/L) 2 dB(A)
Refrigerant charge (R-22) kgSound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Machine weight kg
Certified operation range °CDB
Certified operation range °CWB
Piping connections
mmLiquid (Flare)
Max. installation level differenceBoth liquid and gas pipingHeat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Airflow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Dimensions (HXWXD)
Colour
mm
Max. interunit piping length mm
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Power supply VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Power supply VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
19.4 to 5419.4 to 46 19.4 to 46
3.10/3.10 (V1)3.08/3.08 (Y1)
3.90/3.90 (V1)3.85/3.85 (Y1)
(Charged for 10 m)
(Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
(Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
kWMotor outputCompressor Type
kWMotor outputCompressor Type
kWMotor outputCompressor Type
kWMotor outputCompressor Type
Note : 1Rated cooling capacities are based on the following conditions: 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bIndoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R140LU is 7.5 m.)2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3This value is for when year-round cooling kit (option) is installed.
Note : 1Rated cooling capacities are based on the following conditions: 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bIndoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R125LU is 7.5 m.)2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3This value is for when year-round cooling kit (option) is installed.
o/ 6.4o/ 12.7
o/ 6.4o/ 15.9
I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32
o/ 6.4o/ 15.9
o/ 9.5o/ 15.9
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)
o/ 9.5o/ 19.1
o/ 26.0 (Hole)
o/ 6.4o/ 12.7
o/ 6.4o/ 15.9
I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26
o/ 6.4o/ 15.9
o/ 9.5o/ 15.9
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)
o/ 9.5o/ 15.9
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26 I.Do/ 20XO.Do/ 26o/ 26.0 (Hole) o/ 26.0 (Hole)o/ 26.0 (Hole)
o/ 6.4o/ 12.7
o/ 6.4o/ 15.9
I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32
o/ 6.4o/ 15.9
o/ 9.5o/ 15.9
o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole)
-
White
2.98/ 2.98(V1)2.96/2.96(Y1)
3.90/3.90 (V1)3.85/3.85 (Y1)
Ivory white Hermetically sealed scroll type
71
26,600/26,2007.8/7.7
FAY71LVER71LUV1R71LUY1
6,700/6,600
19670
43/37290X1,050X230
13
2.242.8 (Charged for 30 m)
48770X900X320
72 (V1), 71 (Y1)
100
36,100/35,70010.6/10.5
FAY100FAVER100LUV1R100LUY1
9,100/9,000
23811
45/41360X1,570X200
26
3.003.7 (Charged for 30 m)
491,170X900X32087 (V1), 84 (Y1)
WALL MOUNTED TYPE
30
21 to 46, -15 to 46 3 (Option installed)
14 to 25
50 (equivalent length 70 m)
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
ModelName
Indoorunit
Indoor unit
Outdoor unit
Sound level (H/L) 2 dB(A)
Refrigerant charge (R-22) kgSound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Machine weight kg
Certified operation range °CDB
Certified operation range °CWB
Piping connections
mmLiquid (Flare)
Max. installation level differenceBoth liquid and gas pipingHeat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Airflow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Dimensions (HXWXD)
Colour
mm
Max. interunit piping length mm
FLOOR STANDING TYPE
White
Ivory white Hermetically sealed scroll type
R125LUY1
71
26,600/26,2007.8/7.7
FVY71LAVER71LUV1R71LUY1
6,700/6,600
41/35
18635
1,850X600X27039
2.242.8 (Charged for 30 m)
48770X900X320
72 (V1), 71 (Y1)
100
36,100/35,70010.6/10.5
FVY100LAVER100LUV1R100LUY1
9,100/9,000
46/4098828
1,850X600X35046
3.003.7 (Charged for 30 m)
491,170X900X32087 (V1), 84 (Y1)
125
44,500/43,60013.0/12.8
FVY125LAVE
11,200/11,000
5.06/5.06
49/431,129
32
1,850X600X35047
3.753.7 (Charged for 30 m)
491,170X900X320
98
30
21 to 46, -15 to 46 3 (Option installed)
14 to 25
50 (equivalent length 70 m)
3.18/3.18 (V1)3.16/3.16 (Y1)
4.03/4.03 (V1)3.98/3.98 (Y1)
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
ModelName
Indoorunit
Indoor unit
Outdoor unit
Sound level (H/L) 2 dB(A)
Refrigerant charge (R-22) kgSound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Machine weight kg
Certified operation range °CDB
Certified operation range °CWB
Piping connections
mmLiquid (Flare)
Max. installation level differenceBoth liquid and gas pipingHeat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Airflow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Dimensions (HXWXD)
Colour
mm
Max. interunit piping length mm
White
35
12,100/11,6003.54/3.4
FHB35FV1
R35GV1
3,040/2,930
11.5405
38/32300X700X800
30
1.11.10
48540X750X270
37
45
17,700/17,5005.19/5.1
FHB45FV1
R50GV1
4,460/4,400
14494
39/34300X700X800
31
1.71.20
49540X750X270
42
60
22,760/22,2006.6/6.5
FHB60FV1
R60GV1 R125LUY1
5,690/5,600
17600
41/35300X1,000X800
41
2.21.50
54685X800X300
61
71
26,600/26,2007.8/7.7
FHYB71FV1R71LUV1R71LUY1
6,700/6,600
19670
41/35300X1,000X800
41
2.242.8
48770X900X320
72 (V1), 71 (Y1)
100
36,100/35,70010.6/10.5
FHYB100FV1R100LUV1R100LUY1
9,100/9,000
27953
41/35300X1,400X800
51
3.003.7
491,170X900X32087 (V1), 84 (Y1)
125
44,500/43,60013.0/12.8
FHYB125FV1
11,200/11,000
351,23544/38
300X1,400X800
5255X880X500
3.5
55X880X500
3.5
55X1,100X500
4.5
55X1,100X500
4.5
55X1,500X500
6.5
55X1,500X500
6.5
3.753.7
491,170X900X320
98
CEILING MOUNTED BUILT-IN TYPE
Ivory white Hermetically sealed scroll typeHermetically sealed rotary type
3.13/3.13 (V1)3.11/3.11 (Y1)
4.00/4.00 (V1)3.95/3.95 (Y1)1.47/1.46 2.33/2.32 2.78/2.76 4.74/4.74
Both liquid and gas piping
21 to 46, -15 to 46 3 (Option installed)
14 to 25
----------
----------
3015
14 to 23
50 (equivalent length 70 m)3025
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoorunit
Indoor unit
Outdoor unit
Dimensions(HXWXD)
Colour
mmmm
Sound level (H/L) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Unit
Piping connections
mmLiquid (Flare)
Heat insulationMax. installation level difference
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Decoration panel
UnitDecoration panel
Machine weight kgkgUnit
Decoration panel
Airflow rate (H) m3/mincfm
Outdoorunit
Colour
mm
Certified operation range
Max. interunit piping length mm
41 42
9,000/8,9002.64/2.60
2,270/2,250
13458
41/38260X900X580
22
12,100/11,9003.54/3.50
3,040/3,010
13458
41/38260X900X580
22
18,200/18,1005.34/5.30
4,590/4,560
13458
41/38260X900X580
23
24,000/23,8007.03/6.97
6,050/6,00026,600/26,200
7.80/7.70
6,700/6,600
18635
42/39260X1,300X580
31
18635
42/39260X1,300X580
31
Cooling capacity 1a/1b, 4 kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD) mmSound level (H/L) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H)
Fan Driving system
m3/mincfm
Outdoorunit
mm
Certified operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
R25JV1 R35JV1 R50GV1 R60GV1 R71FUV1R71FUY1
2.82/2.802.06/2.051.25/1.240.88/0.87 2.76/2.75
14 to 2514 to 23
Direct drive (2 speed)
Colour
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Power supply VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Power supply VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Power supply VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
19.4 to 5419.4 to 46 19.4 to 46
(Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
kWMotor outputCompressor Type
kWMotor outputCompressor Type
kWMotor outputCompressor Type
kWMotor outputCompressor Type
1.11.0
48560X695X265
33
1.71.20
49540X750X270
42
2.21.50
54685X800X300
61
2.22.10
52816X880X370
87 (V1), 84 (Y1)
Ivory white Hermetically sealed typeHermetically sealed rotary type
Both liquid and gas piping
21 to 52
301550 (equivalent length 70 m)3025
19.4 to 5419.4 to 46 19.4 to 46
(Charged for 10 m)
0.70.8
46560X695X265
27
(Charged for 10 m) (Charged for 10 m) (Charged for 5 m) (Charged for 5 m)
DUCT CONNECTION LOW STATIC PRESSURE TYPE
Note : 1Rated cooling capacities are based on the following conditions:(FHB) 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bSuction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R125LU is 7.5 m.)(FAY) 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bIndoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R100LU is 7.5 m.)2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3This value is for when year-round cooling kit (option) is installed.
Note : 1Rated cooling capacities are based on the following conditions:(FVY) 1aIndoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bIndoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R125LU is 7.5 m.)(FDBG) 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bSuction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3This value is for when year-round cooling kit (option) is installed.4Capacities are gross, with no deduction made for evaporator fan motor heat.
o/ 6.4o/ 12.7
o/ 6.4o/ 15.9
I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32
o/ 6.4o/ 15.9
o/ 9.5o/ 15.9
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)
o/ 9.5o/ 15.9
I.Do/ 13XO.Do/ 18
o/ 9.5o/ 19.1
I.Do/ 20XO.Do/ 26o/ 26.0 (Hole) o/ 26.0 (Hole)
o/ 9.5o/ 15.9
I.Do/ 20XO.Do/ 26
o/ 9.5o/ 19.1
I.Do/ 20XO.Do/ 26
o/ 9.5o/ 19.1
I.Do/ 20XO.Do/ 26o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)
o/ 6.4o/ 12.7
o/ 6.4o/ 15.9
3/4B 3/4B 3/4B 3/4B
o/ 6.4o/ 15.9
o/ 9.5o/ 15.9
o/ 18.0 (Hole)
o/ 6.4o/ 9.53/4B
o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 18.0 (Hole) o/ 26.0 (Hole)
25FDBG25AVE
35FDBG35AVE
50FDBG50AVE
60 71FDBG60AVE FDBG71AVE
-
43 44
DUCT CONNECTION HIGH STATIC PRESSURE TYPE
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoor unitOutdoor unit
Dimensions (HXWXD) mmSound level (H) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Brazing)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H)
Fan External static pressureDriving system
m3/mincfm
Pa(mmH2O)
Outdoorunit
mm
Certified operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
Colour
Power supply
kWMotor outputCompressor Type
----------
Ivory white
Both liquid and gas piping30
50 (equivalent length 70 m)
14 to 25
Belt drive98 (10) 147 (15)
Y1: 3 phase, 380–415 V, 50 Hz
21 to 52
Hermetically sealed scroll type
3/4B 1B
200 250 400 500FD08KY1 FD10KY1
24.3/24.0 29.7/29.2
RU08KUY1 RU10KUY1
682,400
832,929
500X1,130X850 500X1,330X85093 104
53
FD15KY1 FD20KY1RU08KUY1X2
48.6/47.9 59.3/58.4
RU10KUY1X2
1364,800
1665,859
625X1,620X850 625X1,980X850161 187
58 60
83,000/81,800 101,200/99,600 166,000/163,500 202,400/199,40020,900/20,600 25,500/25,100 41,800/41,200 51,000/50,200
51
7.5/7.4 9.9/9.8 15.0/14.8 19.8/19.6
185 200
60 61
5.0 (Charged for 5 m)
6.1 (Charged for 5 m)
185X2 200X2
60 3 61 3
5.0 (Charged for 5 m)X2
6.1 (Charged for 5 m)X2
1,220X1,280X690 1,440X1,280X690 (1,220X1,280X690)X2 (1,440X1,280X690)X2
7.5 9.0 7.5X2 9.0X2
o/ 12.7 o/ 15.9 o/ 12.7X2 o/ 15.9X2o/ 25.4 o/ 31.8 o/ 25.4X2 o/ 31.8X2
----------
Note : Models RU08K(U)Y1 and RU10K(U)Y1 are recommended for commercial facilities.1Rated cooling capacities are based on the following conditions: 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bSuction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3Specification for outdoor unit is for a single unit only.
----------
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
71
26,600/26,2007.8/7.7
FDYM03FAV1
6,700/6,600
20706
39295X1,100X680
42
2.242.8 (Charged for 30 m)
48770X900X320
72 (V1), 71 (Y1)
100
36,100/35,70010.6/10.5
FDYM04FAV1
9,100/9,000
26917
39295X1,500X680
56
3.003.7 (Charged for 30 m)
491,170X900X32087 (V1), 84 (Y1)
125
44,500/43,60013.0/12.8
FDYM05FAV1
11,200/11,000
351,235
44295X1,500X680
57
3.753.7 (Charged for 30 m)
491,170X900X320
98
140
49,400/48,40014.5/14.2
FDYM06FAV1
12,500/12,200
371,306
98(10) 98(10) 98(10) 98(10)46
295X1,500X68057
4.504.1 (Charged for 30 m)
541,345X900X320
109
Both liquid and gas piping
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD) mmSound level (H) 2 dB(A)
Refrigerant charge (R-22) kgSound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H)Fan
External static pressure
m3/mincfm
Pa(mmH2O)
Outdoorunit
mm
Certified operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
R71LUV1R71LUY1
R100LUV1R100LUY1 R125LUY1 R140LUY1
3.25/3.25 (V1)3.23/3.23 (Y1)
4.08/4.08 (V1)4.03/4.03 (Y1) 5.06/5.06 5.18/5.18
Hermetically sealed scroll type
21 to 46, -15 to 46 3 (Option installed)
14 to 25
3050 (equivalent length 70 m)
Ivory white
Colour
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
kWMotor outputCompressor Type
----------
71 100 125 140
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoor unitOutdoor unit
Dimensions (HXWXD) mmSound level (H) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H)
Fan External static pressureDriving system
m3/mincfm
Pa(mmH2O)
Outdoorunit
mm
Certified operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
Colour
Power supply
kWMotor outputCompressor Type
Ivory white
Both liquid and gas piping30
50 (equivalent length 70 m)
14 to 25
FD03KY1 FD04KY1 FD05KY1R71FUY1
8.1/ 7.927,800/27,000
11.0/10.8 14.0/13.8
R100FUY1 R125FUY1
26917
301,059
461,623
450X650X85051 59 72
4946Belt drive
88 (9)69 (7)
Y1: 3 phase, 380–415 V, 50 Hz
FD06KY1RU06KY1
17.4/17.237,700/36,900 47,600/46,800 59,500/58,800
7,000/6,800 9,500/9,300 12,000/11,800 15,000/14,800
521,835
450X1,130X85079
51
2.50/2.48 3.52/3.48 4.19/4.15 5.7/5.7
450X900X850
Hermetically sealed type
84 109 110
52 56 57
21 to 52
2.1 (Charged for 5 m)
2.4 (Charged for 5 m)
2.8 (Charged for 5 m)
Hermetically sealed scroll type
112
59
3.0 (Charged for 5 m)
816X880X370 1,215X880X370 1,345X880X320
3.0 3.8 4.5 4.5
Note : 1Rated cooling capacities are based on the following conditions: 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bSuction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R140LU is 7.5 m.)2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3This value is for when year-round cooling kit (option) is installed.
o/ 9.5o/ 15.9
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32
3/4B
o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5o/ 15.9 o/ 19.1 o/ 19.1 o/ 19.1
o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) ----------
----------
71
30,000/29,6008.8/8.7
FDMG71AV1
7,600/7,500
2381142
305X1,350X68043
2.202.4 (Charged for 5 m)
52816X880X370
87 (V1), 84 (Y1)
100
36,100/35,70010.6/10.5
FDMG100AV1
9,100/9,000
341,200
44305X1,550X680
51
3.002.4 (Charged for 5 m)
561,215X880X370
117 (V1), 109 (Y1)
125
44,500/43,60013.1/12.9
FDMG125AV1
11,200/11,000
371,306
45305X1,550X680
52
3.752.8 (Charged for 5 m)
571,215X880X370
110
140
49,400/48,40014.5/14.2
FDMG140AV1
12,500/12,200
421,412
46305X1,550X680
52
4.50Hermetically sealed scroll type
2.9 (Charged for 5 m)55
1,345X880X370113
Both liquid and gas piping
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoor unit
Outdoor unit
Dimensions (HXWXD) mmSound level (H) 2 dB(A)
Refrigerant charge (R-22) kgSound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)
Heat insulation
mmGas (Flare)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H)Fan m3/mincfm
Outdoorunit
mm
Certified operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
RG71AV1RG71AY1
R100FUV1R100FUY1 R125FUY1 RG140AY1
3.15/3.13 4.08/4.04 4.89/4.85 5.25/5.25
Hermetically sealed type
21 to 52 21 to 50
14 to 25
3050 (equivalent length 70 m)
Ivory white
Colour
Power supply V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
kWMotor outputCompressor Type
o/ 9.5o/ 15.9
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
o/ 9.5o/ 19.1
o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)3/4B 3/4B 3/4B 3/4B
180
58,700/57,50017.2/16.8
FDMG180AV1
14,700/14,400
421,482
47305X1,900X680
58
4.502.8 (Charged for 5 m)
561,345X880X370
114
RG180AY1
6.45/6.45
o/ 9.5o/ 19.1
o/ 26.0 (Hole)3/4B
-
45 46
DUCT CONNECTION HIGH STATIC PRESSURE TYPE
Cooling capacity 1a/1b kWBtu/hkcal/h
kWPower consumption 1a/1b
°CDB
°CWBCertified operation range
ModelName
Indoor unitOutdoor unit
Dimensions (HXWXD) mmSound level (H) 2 dB(A)
Refrigerant charge (R-22) kg
Sound level 2 dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Brazing)
Heat insulation
mmGas (Brazing)mmDrain Indoor unit
Outdoor unit
kg
Airflow rate (H)
Fan External static pressureDriving system
m3/mincfm
Pa(mmH2O)
Outdoorunit
mm
Certified operation range
Max. interunit piping length mm
Machine weight
Indoorunit
Colour
Max. installation level difference
Colour
Power supply
kWMotor outputCompressor Type
Note : Models RU08K(U)Y1 and RU10K(U)Y1 are recommended for commercial facilities.1Rated cooling capacities are based on the following conditions: 1aSuction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 1bSuction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). 2Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
3Specification for outdoor unit is for a single unit only.4This is the amount of refrigerant required for piping of five meters or less. Since the unit does not contain refrigerant when shipped from the factory, it must be added at the installation site. For details, please refer to the installation manual.
----------
Ivory white
Both liquid and gas piping30
50 (equivalent length 70 m)
14 to 25
Belt drive98 (10) 147 (15)
Y1: 3 phase, 380–415 V, 50 Hz
21 to 52
Hermetically sealed scroll type
3/4B 1B
200 250 400 500FD08KY1 FD10KY1
24.3/24.0 29.7/29.2
RU08KY1 RU10KY1
682,400
832,929
500X1,130X850 500X1,330X85093 104
53
FD15KY1 FD20KY1RU08KY1X2
48.6/47.9 59.3/58.4
RU10KY1X2
1364,800
1665,859
625X1,620X850 625X1,980X850161 187
58 60
83