fbc-007 flat cleaver for pretium unicam | test...

4
p/n 006-392, Issue 2 STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | APRIL 2011 | PAGE 1 OF 4 | PRETERMINATED SYSTEMS | CABLES | CONNECTORS | CABLE ASSEMBLIES | HARDWARE | TOOL KITS AND ACCESSORIES | TEST EQUIPMENT | SPLICE EQUIPMENT | FAN-OUT KITS | TRAINING FBC-007 Flat Cleaver for Pretium ® UniCam ® 1. COMPONENTS Number Components 1 Keep Button (Black) 2 Scrap Button (Red) 3 Cleave Button (Blue) 4 Fiber Handler 5 Latch 6 Strip Length Guide 2. FIBER PREPARATION Step 1: Strip fiber a minimum of 40mm. TPA-3711 1 4 5 6 2 3 40mm minimum TPA-3712 Step 2: Check fiber against strip length guide. TPA-3713 3. CLEAVING JACKETED FIBER Step 1: Flip fiber handler. Step 2: Follow Steps 1 through 8 for in Section 4 for cleaving 900 micron fiber. TPA-3720

Upload: trinhanh

Post on 28-Apr-2018

217 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: FBC-007 Flat Cleaver for pretium UniCam | TEST …store.stsi.com/assets/files/corning/fbc-007-instructions.pdf · STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE

p/n 006-392, Issue 2

STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE 1 OF 4

| PR

ETE

RM

INAT

ED

SY

STE

MS

| C

AB

LES

| C

ON

NE

CTO

RS

| C

AB

lE A

SS

EM

BlI

ES

| H

AR

DW

AR

E |

TOO

L K

ITS

AN

D A

CC

ES

SO

RIE

S |

TES

T E

QU

IPM

EN

T | S

PLI

CE

EQ

UIP

ME

NT

| FA

N-O

UT

KIT

S |

TRA

ININ

GFBC-007 Flat Cleaver for pretium® UniCam®

1. COMPONENTS

Number Components1 Keep Button (Black)2 Scrap Button (red)3 Cleave Button (Blue)4 Fiber Handler5 latch6 Strip length Guide

2. FIBER PREPARATIONStep 1: Strip fiber a minimum of 40mm.

TPA-3711

14

56

2

3

40mm minimum

TPA-3712

Step 2: Check fiber against strip length guide.

TPA-3713

3. CLEAVING JACKETED FIBERStep 1: Flip fiber handler.

Step 2: Follow Steps 1 through 8 for in Section 4 for cleaving 900 micron fiber.

TPA-3720

Page 2: FBC-007 Flat Cleaver for pretium UniCam | TEST …store.stsi.com/assets/files/corning/fbc-007-instructions.pdf · STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE

STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE 2 OF 4

4. CLEAVING 900 MICRON FIBER

5. CLEAVING FOR 250 MICRON AND UNICAM® FANOUT APPLICATIONSStep 1: Add handler track to cleaver.

a. Remove 900/2.9 handler. b. Depress latch and lift cover.

TPA-3721 TPA-3722

TPA-3714

TPA-3715 TPA-3716

TPA-3717

TPA-3718

TPA-3719

Depress Black and Red buttons. Insert fiber until it stops. Release buttons.

Cycle Red Button once. Press Blue Button.

Check cleave length against guide.

Hold scrap fiber and pressRed Button to remove.

Hold fiber and pressBlack Button to remove.

TPA-3713

TPA-3717

TPA-3852

1 2 3

4 5

7 8

6

Page 3: FBC-007 Flat Cleaver for pretium UniCam | TEST …store.stsi.com/assets/files/corning/fbc-007-instructions.pdf · STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE

STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE 3 OF 4

c. Insert handler track. d. Press firmly to close.

TPA-3723

PressLatch

TPA-3724

Step 2: Strip fiber and check length against guide.

Step 3: Load fiber into Blue UniCam fanout handler.

TPA-3725

Step 4: Depress red and Black buttons and load handler with fiber into cleaver.

Step 5: Cycle Red button once.

TPA-3728 TPA-3729

Step 6: Press Blue button. Step 7: press Black button and slide handler out of the cleaver.

TPA-3730TPA-3731

Step 8: Remove fiber from handler and check cleave length against guide.

Step 9: Hold scrap fiber and press Red button to remove.

TPA-3725

TPA-3732

TPA-3739Align fanout tubing to scribe line

Align coating to nose.OptiSnap 900 Micron Application (Blue Handler)

Page 4: FBC-007 Flat Cleaver for pretium UniCam | TEST …store.stsi.com/assets/files/corning/fbc-007-instructions.pdf · STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE

STANDARD RECOMMENDED PROCEDURE 006-392 | ISSUE 2 | AprIl 2011 | PAGE 4 OF 4

Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA 1-800-743-2671 • FAX +1-828-325-5060 • International +1-828-901-5000 • http://www.corning.com/cablesystems

Corning Cable Systems reserves the right to improve, enhance, and modify the features and specifications of Corning Cable Systems’ products without prior notification. Evolant, Pretium, and UniCam are registered trademarks of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified.

© 2011 Corning Cable Systems. All rights reserved. Published in the USA.

6. TROUBLESHOOTINGproblem possible Causes Solutions (Actions)

Cleaver is producing bad cleaves or breaking fibers.

1. Debris in the clamps 1. Clean the clamps per the instructions.

2. Blade is worn or damaged. 2. Replace the blade per the instructions.

7. MAINTENANCE

7.1. Opening Cleaver for Cleaning or MaintenanceTo open depress latch and lift cover. Depress latch while pressing firmly to close.

TPA-3722

PressLatch

TPA-3716

7.2. CleaningWipe three places with fiber wipes and cleaning fluid. Aggressively clean scrap pad if experiencing fiber breaks

7.3. Replacing BladeStep 1: remove two screws, blade block,

and blade with blade pin.Step 2: replace blade and reuse blade

pin.

TPA-3734

Screws

Blade Block

Blade and Blade Pin

KPA-1000

Used Blade

ReplacementBlade

Blade Pin

TPA-3733

Clamp Arms

Clamp Arm

Scrap Pad

Scrap Pad