FBF-309-L
DESCRIPTION FEATURESLow insertion loss and good VSWR are achieved in this high Q, EMP protected bandpass filter. The model FBF-309-L features an EMP protection clamp voltage of 150V.
} Bandpass Filter
} EMP Protected
FBF-309-L
MPI Metropole Products, Inc.2040 Jefferson Davis Hwy. • Stafford,Virginia 22554 • 540.659.2132fx. 540.659.2133 • e. [email protected] www.MetropoleProducts.com
Description
Low insertion loss and good VSWR are achieved in this high Q, EMP protected bandpass � lter. The model FBF-309-L features an EMP protection clamp voltage of 150 V.
Features
• Bandpass Filter • EMP Protected
P: 540.659.2132 F: 540.659.2133
2040 Jefferson Davis Highway, Stafford, Virginia 22554
www.MetropoleProducts.com
FBF-309-L
SPECIFICATIONS
Center Frequency, nominal ............................................................................................................................................................................... 167 MHz
1 dB Bandwidth, Note 1 ............................................................................................................................................................................... 16 MHz min.
40 dB Bandwidth ........................................................................................................................................................................................ 45 MHz max.
Insertion Loss ................................................................................................................................................................................................1.5 dB max.
VSWR over 160 to 174 Mhz ......................................................................................................................................................1.6:1 max., 1.5:1 at center
Impedance ....................................................................................................................................................................................................50Ω nominal
Connectors ................................................................................................................................................................................................... TNC Female
Weight ..................................................................................................................................................................................................................... 15 oz.
Clamp Voltage Protection ........................................................................................................................................................................... 150V nominal
Note 1: Bandwidth is measured from the minimum insertion loss value. The lower 1 dB frequency must be ≤ 159 MHz, the upper 1 dB frequency must be ≥ 175 MHz
FBF-309-L
MPI Metropole Products, Inc.2040 Jefferson Davis Hwy. • Stafford,Virginia 22554 • 540.659.2132fx. 540.659.2133 • e. [email protected]
Speci� cations
Center Frequency, nominal .................................................................................................................................................................................................................................. 167 MHz1 dB Bandwidth, Note 1 ..............................................................................................................................................................................................................................16 MHz min.40 dB Bandwidth .......................................................................................................................................................................................................................................... 45 MHz max.Insertion Loss ...................................................................................................................................................................................................................................................1.5 dB max.VSWR over 160 to 174 Mhz ....................................................................................................................................................................................................1.6:1 max., 1.5:1 at center.Impedance .....................................................................................................................................................................................................................................................50Ω nominalConnectors .......................................................................................................................................................................................................................................................TNC FemaleWeight ....................................................................................................................................................................................................................................................................... 15 oz.Clamp Voltage Protection ........................................................................................................................................................................................................................... 150 V nominal
Note 1: Bandwidth is measured from the minimum insertion loss value. The lower 1 dB frequency must be ≤ 159 MHz, the upper 1 dB frequency must be ≥ 175 MHz
REV: 2/18/2015