features & benefits minimum roof pitch 2 · pdf filefor rev-5 a minimum roof pitch of 2...
TRANSCRIPT
REV-5
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 55641
REV-5REVSPEC
RR12.1
Note: On a roof pitch less than 3 degrees, we recommend that the pans be turned down in to the gutter and turned up at the ridge line in accordance with Australian Standards SAA HB39 - 1997 Installation Codeformetalroofingandwallcladding.Itis recommended that sheet lengths greater than 24m willrequireanexpansionjoint.
REV-5 Masses
MeasurementZincalume 0.35 BMT
Colorbond 0.35 BMT
Zincalume 0.42 BMT
Colorbond 0.42 BMT
Zincalume 0.48 BMT
Colorbond 0.48 BMT
kg/lm 2.74 2.79 3.26 3.32 3.7 3.76
kg/m23.60 3.67 4.28 4.35 4.86 4.93
m2/t 278 272 234 230 206 203
TheREV-5hasbeentestedtothefollowingstandards:
• AS1562.1-1992Designandinstallationofsheetroofandwallcladding.
• AS4040-1992Methodsoftestingsheetroofand wallingcladding-Part0:Introduction,listofmethodsandgeneralrequirements-Part2:Methodsoftestingsheet roof and wall cladding - Resistance to wind pressuresfornon-cycloneregions.
• TheREV-5ismanufacturedtoAS1397andAS2728standards.
• TheREV-5requiresinstallationtofollowtheAS1445andAS1565standardsfollowingtheHB39code.
• NCC-BCALo-HiCyclonicTests.
TOLERANCE & MASSES
MINIMUM ROOF PITCH 2 DEGREES
MATERIAL SPECIFICATIONS
RevolutionRoofingonlyuse100%BlueScopeSteelproducts.
ZINCALUME® steel aluminium/zinc alloy-coated steel complyingwithAS1397-2001G550,AZ150(550MPaminimumyieldstress,150g/m2 minimum coating mass); or StainlessSteelstandardgradedesignationisAISI/ASTMType430;UNSNo.S43000.
COLORBOND®steelmetalthicknessis0.35,0.42or0.48mm.G550,AZ150(550MPaminimumyieldstress,150g/m2minimumcoatingmass).COLORBOND® Ultra base metalthicknessis0.42or0.48mm.G550,AZ200(550MPaminimumyieldstress,200g/m2 minimumcoatingmass).
COLORBOND® steel.60BlueOrbG300,AZ150(300Mpaminimumyieldstress,150g/m2minimumcoatingmass).COLORBOND®Metallicsteelbasemetalthicknessis0.48mm.G550,AZ150(550Mpaminimumyieldstress,150g/m2minimumyieldstress,150g/m2minimumcoatingmass).TheCOLORBOND® prepainted steel complies with AS/NZS2728:1997.
TolerancesLength: +7mm/ -7mm Width: +4mm/ -4mm
ForREV-5aminimumroofpitchof2degreesisrecommended.
ThedistinctlinesallowtheprofiletocreateacontemporaryfinishallowingtheREV-5tobetheperfectsolutionfordomesticandcommercialapplications.REV-5canbeusedasbotharoofingandwallingproduct.REV-5provideseconomywithits762mmcoverageaswellasversatilityinallapplications.
The subtle square shaped rib of 27mm ensures greater strength, spanning capability, lightness and rigidity enabling the optimisation of the roof design for a cost effectiveoutcome.Withitseaseofinstallationroofershaveusedthisreliableandstrongprofileforover40years.
FEATURES & BENEFITS
• 762mmcoverage.• Improvedlapping&capillaryaction.• Choiceofpans&stiffenersinvaryingprofiles.• Suitableforbothroofing&claddingapplications.
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 55642
REV-5REV-5REVSPEC
SERVICEABILITY AND STRENGTH
Cyclonic 0.42 BMT & 0.48 BMTLo Hi Lo - CYCLONIC Wind Uplift Resistance -
StrengthLimitStateDesigntoBCA
Span
(mm)
0.42 BMT 0.48 BMT
End Span (kpa)
Internal Span (kpa)
End Span (kpa)
Internal Span (kpa)
900 7.02 - 7.60 -
1200 4.43 6.55 5.03 7.14
1500 2.97 4.39 3.42 4.98
1800 2.07 3.16 2.50 3.63
2100 1.50 2.44 2.01 2.82
2400 - 1.82 - 2.29
Revolution Roofing REV-5RecommendedMaximumSupportSpacings(mm)SPANTABLE
Wall Span 0.35 BMT 0.42 BMT 0.48 BMT
Single Span 1700 2300 2700
End Span 2200 1800 1500
Internal Span 2400 2350 2000
Stiffened Eaves Overhang 300 300 350
Non-Cyclonic 0.42 BMTNON-CYCLONIC Wind Uplift Resistance - ServiceandStrengthLimitStateDesign
Span
(mm) End Span (Trend)
Span
(mm) Internal Span (Trend)
Serviceability (kPa)
Strength (kPa)
Serviceability (kPa)
Strength (kPa)
900 3.27 6.07 1200 3.13 5.91
1200 2.43 4.94 1500 2.43 4.93
1500 1.77 4.06 1800 1.85 4.13
1800 1.24 3.35 2100 1.37 3.46
Non-Cyclonic 0.48 BMTNON-CYCLONIC Wind Uplift Resistance - ServiceandStrengthLimitStateDesign
Span
(mm)
End Span (Trend)
Span
(mm)
Internal Span (Trend)
Serviceability (kPa)
Strength (kPa)
Serviceability (kPa)
Strength (kPa)
900 3.49 7.18 1200 3.39 7.10
1200 2.25 6.05 1500 2.34 6.14
1500 1.29 5.17 1800 1.48 5.36
1800 0.50 4.45 2100 0.76 4.69
Note:
1. Forroofingthedataisbasedonfoottrafficloading.2. Forwallingthedataisbasedonwindpressure.3. Theabovedatatableisbasedonsupportsof1.5mmBMT.4. 0.35BMTisrecommendedforwallingapplicationsonly.
Revolution Roofing REV-5RecommendedMaximumSupportSpacings(mm)SPANTABLE
Roof Span 0.42 BMT 0.48 BMT
Single Span 1000 1700
End Span 1600 2000
Internal Span 2000 2750
Unstiffened Eaves Overhang 200 250
Stiffened Eaves Overhang 350 350
SPAN TABLE NON-CYCLONIC
Design Parameters
STANDARD INTERPRETATION OF SPANS
Internal End
KL 1.0 KL 2.0
∑C=-0.85 ∑C=-1.50
Pu = 1.03kPa 1.82kPa
Ps = 0.70kPa 1.23kPa
Internal Span
End Span
End Span
O
O
Internal Span
End Span
End Span
O
O
O = Overhang
Single Span
End Bay
Internal Bay
Region A:Terrain Category 2Height=10mKL =2.0Vz=45m/secq*u =1.215kPaqs =0.821kPaCp.e=-0.65Cp.i=0.20
Note:
Table limits for walls based on pressuresstatedinabovetable.
Theabovecyclonicdataisbasedonsupportsof1.5mmBMTG450steelsectionsandthefollowingfixings:Screws = 14g-10tpix50mmhexheadWashers= BXSQUARELOK38hexhead1mmthick washers.
Theabovecyclonicdataisbasedonsupportsof1.5mmBMTG450steelsectionsandthefollowingfixings:Screws = M6.2-13tpix50mmhexheadwithseal
REV-5
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 5564
FASTENER SPACING NON-CYCLONIC
3
REV-5REVSPEC
Maximum Support Spacings
ThemaximumrecommendedsupportspacingsarebasedontestinginaccordancewithAS1562.1-1992,AS4040.1-1992andAS4040.2-1992.Therecommendedroofspanstakeintoconsiderationbothresistancetowindpressureandlightrooftraffic(trafficarisingfrommaintenance).Thewallspanstakeintoconsiderationtheresistancetowindpressureonly.
4 fasteners per sheet - end supports and end laps
Crest Fastener Location
FASTENER SPACING CYCLONIC
4 fasteners per sheet - end supports and end laps
Pan Fastener Location
Note: Mostcommonpracticeis:4fastenersforinternalspansand4fastenersforsingleandendspans,equatingto5-6 screwpersquaremetre.
4 fasteners per sheet - end supports and end laps
Crest Fastener Location
4 fasteners per sheet - end supports and end laps
Note: Mostcommonpracticeis:4fastenersforinternalspansand5fastenersforsingleandendspans.
Pan Fastener Location
Note: Afterexposureofcladdingtoanextremewindevent,itisrecommendedthatinspectionbeperformedtoconfirm claddingintegrity.
*Theabovedatadisplayedisbasedontrenddata,whichisatruerepresentationoftheaverageproductcapability.
OPTIONAL V-SHAPED ALTERNATE PAN DETAIL
RevolutionRoofingalsoofferanoptionalalternatepandetailfortheREV-5profile.ForfurtherinformationregardingthisadditionaloptionpleasedonothesitatetocontactyournearestRevolutionRoofingoffice.
MILE END SOUTH SA55 Scotland Road
P: 08 8352 0911 F: 08 8352 0922
LONSDALE SA14 Bredbo Street
P: 08 8186 0545 F: 08 8186 1341
OSBORNE PARK WA55b Hector Street
P: 08 9217 9011 F: 08 9204 55644
REV-5REV-5REVSPEC
REV-5 Cyclonic Pierce Fixing
Type Fixing to Steel Fixing To Timber
Cres
t Fixe
d M6.2-13x50mmHexHeadHG/Sea+Squarelokwashers5-691-01-010-2C4,
1mm thick, class 4
M6.2-13x50mmHexHeadHG/Seal+Squarelokwashers5-691-01-010-2C4,
1mm thick, class 4
Pan
Fixe
d 10-16x16mmMetalTekshexagon head with seal +
Squarelokwashers5-691-01-010-2C4,1mmthick,class4
M6-11x25mmRoofzipshexagon head with seal +
Squarelokwashers5-691-01-010-2C4,1mmthick,class4
Side
Lap
&
Acce
ssor
ies Self drilling needle point stitching screws with hex, slot-head EPDMseal:8-15x15alternativelyselfdrillingscrewswithhex,
washer-head&EPDMseal:10-16x16orsealedblindrivets:4.8mmdiameteraluminium.
Side Laps
RevolutionRoofingrecommendusingsidelapfastenersatmidspanswhenusingtheREV-5atitsmaximumlength.Thisensuresthesheetlapsareheldfirmlyinplaceandhelpreducethe possibility of future leaks that arise from expansion and contraction.TheedgeoftheREV-5withitsimprovedcapillaryactionshouldalwaysbeusedastheunderlap.Whencladdingis supported, side lap fasteners are generally not needed for extrastrength.
Turning of Sheeting Ends
It is common practice to overlap sheets into box gutters by 150mmwhenroofpitchislessthan10º.Thepansofthesheets should be turned down at lower ends and turned up at upperends.WhenREV-5islaidonapitchlessthan5degrees, cut back the corner of the undersheet at the downhillendofthesheettoblockcapillaryaction.
Lengths
Sheetsaresuppliedcustomcuttolonglengths.
INSTALLATION & SCREWS NON-CYCLONIC
Fixing to Timber
REV-5canbecrestorpanfixedtotimberorsteelsupportswiththerecommendedfastenersnolessthan30mmfromsheetends.
Fixing to Steel
CREST OR PAN FIXING
REV-5 Non-Cyclonic Pierce Fixing
TypeFixing to Steel(Up to 1.9mm)
Fixing To Steel(2.0mm - 3.5mm)
Fixing To Timber
Cres
t Fi
xed M6.2-13x50mmHex
HeadHiGripw/-SealSelfDrilling12-14x45mmHexHeadHiGripw/-Seal
M6.2-13x65mmor65mmT17Timber
Pan
Fixe
d M6.2-13x25mmor10-16x16mmMetalTeks Hexagon Head
with Seal-
M6.2-13x25mmor10-12x
25mmT17
Side
Lap
&
Acce
ssor
ies
Selfdrillingneedlepointstitchingscrewswithhex,slot-headEPDMseal:8-15x15alternativelyselfdrillingscrewswithhex,washer-head&EPDMseal:10-
16x16orsealedblindrivets:4.8mmdiameteraluminium.
RECOMMENDED FASTENERS