  www.chinus.net CHINUS TECHNOLOGY FINGERPRINT DOOR LOCK INSTRUCTIONS MODEL FK-420

Upload: weley-melo

Post on 06-Oct-2015

220 views

Category:

Documents


0 download

TRANSCRIPT

  • www.chinus.net CHINUS TECHNOLOGY

    FINGERPRINT DOOR

    LOCK

    INSTRUCTIONS

    MODEL FK-420

  • www.chinus.net CHINUS TECHNOLOGY

    Page 2

    NOTICESPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT

    NOTICE AT ANY TIME. WE ARE NOT RESPONSIBLE FOR ANY

    DAMAGES CAUSED BY USERS MISOPERATION.

    INDEX

    SECTION 1: SAMPLE OF PRODUCT-----------------------------------------------3

    SECTION 2: FUNCTION-----------------------------------------------------------------3

    SECTION 3: SKETCH MAP -------------------------------------------------------------3

    SECTION 4: OPERATION INSTRUCTIONS-----------------------------------------4

    1. Fingerprint Management-----------------------------------------------------------------------------------------------4

    1.1 Registration of fingers--------------------------------------------------------------------------------4

    1.1.1. Registration of manager----------------------------------------------------------------------------------4

    1.1.2. Registration of common user-----------------------------------------------------------------------------5

    1.1.3. Digital inquiry ----------------------------------------------------------------------------------------------5

    1.2 Deletion instructions----------------------------------------------------------------------------------6

    1.2.1. Orientable deletion with finger--------------------------------------------------------------------------6

    1.2.2. Orientable deletion with position------------------------------------------------------------------------6

    1.2.3. Complete deletion------------------------------------------------------------------------------------------7

    2. Lock Functions-----------------------------------------------------------------------------------------------7

    2.1 Unlock with the registered fingers-----------------------------------------------------------------7

    2.2 State of always unlock-------------------------------------------------------------------------------- 7

    2.3 Limited unlock----------------------------------------------------------------------------------------- 8

    2.4 Lock from inside---------------------------------------------------------------------------------------8

    3 . Passw or d- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

    3.1 Unlock with password-------------------------------------------------------------------------------- 8

    3.2 How to set managers password-------------------------------------------------------------------- 8

    3.3 How to set common users password--------------------------------------------------------------9

    SECTION 5: FLOW DIAGRAM--------------------------------------------------------10

    SECTION 6: DOORFRAME DRAWING --------------------------------------------11

    SECTION 7: DOOR LOCK FITTINGS ----------------------------------------------11

    SECTION 8: ATTENTIONS ------------------------------------------------------------12

    SECTION 9: FAQS-----------------------------------------------------------------------13

    SECTION 10: REGISTER LIST ---------------------------------------------------------14

    NOTICE:

    THERE IS NO BATTERY IN THE LOCK FOR THE CONVENIENCE OF

    TRANSPORTATION, SO PLEASE INSTALL THE BATTERY FIRST ACCORDING

    TO THE INSTALLATION CD. THEN START OPERATION WITH THIS MANUAL.

  • www.chinus.net CHINUS TECHNOLOGY

    Page 3

    SECTION 1: SAMPLE OF PRODUCT

    SECTION 2: FUNCTION

    Fingerprint capacity: 80 fingers;

    Easy operation: humanity design for customer;

    5 managers+75 common users management;

    Unlock by fingerprint, ciphers and emergency keys;

    Hotel lock with international standard;

    Digital inquiry about storage quantity and locations;

    Delete the appointed fingerprint;

    Automatic alarm function;

    Low power consumption design;

    SECTION 3: SKETCH MAP

    How to press finger on the collecting window:

    Dimensions 2507533mm

    Weight 1.6 kg

    Operating Voltage 4.76V(DC) Record Capacity 80pcs

    Dynamic Power Consumption 140mA Static Power Consumption 18A

    Resolution 500dpi

    Acceptance Angle 40

    FAR(False Acceptance Rate) 0.0001% FRR(False Rejection Rate) 0.01%

    Matching Time 1s Operation Temperature -555 Operation Humidity 20%80%RH

    Red light

    Green light

    Collecting window

    Button

    Button

    Packing List

    Manual 1 Lock body 1

    AA battery 4 Bolt board 1

    Front panel 1 Bolt case 1

    Back panel 1 Fittings 1

    Mechanical

    key 2

    Quality

    certificate 1

    FK-420

    SPECIFICATIONS

  • www.chinus.net CHINUS TECHNOLOGY

    Page 4

    SECTION 4: OPERATION INSTRUCTIONS

    1. Fingerprint Management

    1.1 Registration of fingers:

    You can register 80 fingers at most, including 5 managers and 75 common users.

    5 managers can not only control the lock functions (e.g. unlock), but also the

    fingerprint management (e.g. register, delete fingerprint); while 75 common

    users can only operate the lock and they are not authorized to manage fingers.

    ATTENTION: As the default setting, there is not any finger in the lock before it

    is in use, so any finger can open it when it is electrified. Therefore, make sure

    to register the fingers as soon as possible to ensure safety.

    1.1.1. Registration of manager (1 ~ 5)

    STEP After the lock is electrified, press button to start. The collecting window turns

    bright and the green light glitters.

    STEP Press button down and dont release the finger until 10 seconds pass. (The

    red light glitters once after 5 seconds and it will glitter twice in all, with a di sound at the

    same time. After the red light glitters twice, release your finger. The collecting window is

    bright and the green light and red light glitter together).

    STEP (If there is no registered finger in the lock, go straight to the next step.) The manager

    presses his registered finger once to confirm. If it succeeds, there will be 3 continuous di

    sounds and the green light glitters; if it fails, the red light turns bright and a di sound is

    emitted to remind you of inputting correct manager finger.

    STEP After confirmation, input finger needed to be registered, input each finger for 3

    times. (The collecting window will be dark after you press finger each time to remind you of

    releasing finger. After hearing the di sound, input the same finger again. 3 times in all).

    STEP After 3 times input, three di sounds are emitted to remind you of registration are

    complete. You can continue to input other managers (repeat the former procedure) or wait to

    do other operations after the collecting window is dark. If the input fails, a di sound is given

    and the red light turns bright to remind you of registering fingers again (repeat the last step).

    NOTE: It is recommended to register not less than 2 managers for the convenience.

  • www.chinus.net CHINUS TECHNOLOGY

    Page 5

    1.1.2. Registration of common user680

    ONLY after the manager is registered, can the common users be registered.

    STEP After the lock is electrified, press button to start. The collecting window turns

    bright and the green light glitters.

    STEP Press button down and dont release the finger until 5 seconds pass. (The

    red light glitters once after 5 seconds, with a di sound at the same time. After that, release

    your finger. The collecting window is bright and the green light and red light glitter together).

    STEP The manager presses his registered finger once to confirm. If it succeeds, there will

    be 3 continuous di sounds and the green light and red light glitter together; if it fails, the red

    light turns bright and a di sound is emitted to remind you of inputting correct manager

    finger.

    STEP After confirmation, input finger needed to be registered, input each finger for 3

    times. (The collecting window will be dark after you press finger each time to remind you of

    releasing finger. After hearing the di sound, input the same finger again. 3 times in all)

    STEP After 3 times input, three di sounds are emitted to remind you of registration are

    complete. You can continue to input other users (repeat the former procedure) or wait to do

    other operations after the collecting window is dark. If the input fails, a di sound is given

    and the red light turns bright to remind you of registering fingers again (repeat the last step).

    NOTE: It is recommended to register not less than 2 fingers for one user.

    1.1.3. Digital inquiry: the amount and location of fingers can be inquired.

    Amount inquiry of fingers

    Amount of manager: When you register a new manager, presses button as soon as

    manager puts in his finger. The glittering times of light show the amounts of managers.

    Amount of common users: when you register a new common user, press button as soon as

    manager puts in his finger. The glittering times of light show the amounts of managers

    Location inquiry of registered fingers

    After the registration (press the fingers needed to register in the third time), press button

    immediately to demonstrate the position of the registered fingers.

    The glittering times of green and red lights stand for the location of users: the glittering times of

    green light are the tens value and red light are the units value. If the light does not glitter, the value

    is zero (e.g. if the green light glitters twice and the red light glitters 3 times, the figure is 23)

  • www.chinus.net CHINUS TECHNOLOGY

    Page 6

    1.2 Deletion instructions:

    1.2.1. Orientable deletion: delete the appointed finger (finger must be input)

    STEP After the lock is electrified, press button to start. The collecting window turns

    bright and the green light glitters.

    STEP Press button down and dont release the finger until 5 seconds pass. (The

    red light glitters once after 5 seconds. After that, release your finger. The collecting window is

    bright and the green light and red light glitter alternately).

    STEP The manager presses his registered finger once to confirm. If it succeeds, there will

    be 3 continuous di sounds and the green light and red light glitter together; if it fails, the red

    light turns bright and a di sound is emitted to remind you of inputting correct manager

    finger.

    STEP After confirmation, input finger needed to be deleted once on collecting window.

    STEP After that, three di sounds are emitted twice to remind you of deletion are

    complete. You can continue to delete other users (repeat the former procedure) or wait to do

    other operations after the collecting window is dark. If the input fails, a di sound is given

    and the red light turns bright to remind you of deleting fingers again (repeat the last step)

    1.2.2 Orientable deletion: delete the appointed finger according to its location (see 1.1.3

    Location inquiry of registered fingers of last page for reference).

    STEP After the lock is electrified, press button to start. The collecting window turns

    bright and the green light glitters.

    STEP Press button down and dont release the finger until 5 seconds pass. (The

    red light glitters once after 5 seconds. After that, release your finger. The collecting window is

    bright and the green light and red light glitter alternately).

    STEP The manager presses his registered finger once to confirm. If it succeeds, there will

    be 3 continuous di sounds and the green and red light glitter together; if it fails, the red light

    turns bright and a di sound is emitted to remind you of inputting correct manager finger.

    STEP After confirmation, input fingers location with two buttons (.e.g. if fingers

    location is 23, press button twice and press button three times, then press

    button to confirm).

    STEP Repeat the last step and input the location once again.

    STEP The green light and red light will glitter to remind you of checking the location

    (The glittering times of green and red lights stand for the location of users: the glittering times

    of green light are the tens value and red light are the units value. If the light does not glitter,

    the value is zero).

    STEP After confirmation, press button once to finish the deletion.

  • www.chinus.net CHINUS TECHNOLOGY

    Page 7

    1.2.3. Complete deletion: delete all fingers, including managers and common users.

    STEP After the lock is electrified, press button to start. The collecting window turns

    bright and the green light glitters.

    STEP Press button down and dont release the finger until 10 seconds pass. (The

    red light glitters once after 5 seconds and it will glitter twice in all, with a di sound at the

    same time. After the red light glitters twice, release your finger. The collecting window is

    bright and the green light and red light glitter alternately).

    STEP The manager presses his registered finger once to delete all common users. If it

    succeeds, there will be 3 continuous di sounds and the green light and red light glitter

    together; if it fails, the red light turns bright and a di sound is emitted to remind you of

    inputting correct manager finger.

    STEP The manager presses his registered finger once again to delete all managers. If it

    succeeds, there will be 3 continuous di sounds and the green light and red light glitter

    together; if it fails, the red light turns bright and a di sound is emitted to remind you of

    inputting correct manager finger.

    2. Lock Functions

    2.1 Unlock with the registered fingers

    STEP After the lock is electrified, press button to start. The collecting window

    turns bright and the green light glitters.

    STEP Press the registered finger once in the center of collecting window with a little

    strength.

    STEP Lock opens and you can twist the door handle to unlock. After 3 seconds, it locks.

    2.2 State of always unlock: the door will always be open.

    STEP Open the lock first.

    STEP After the lock is open, twist the lock handle downwards immediately or press down

    button . Dont release finger until 5 seconds pass (after 5 seconds, a di sound is

    given to remind you of releasing finger).

    STEP Under this condition, anyone can open it without registered finger.

    STEP Twist the lock handle downwards or press down button for another 5 seconds

    to back into the normal status (Dont release finger until 5 seconds pass, after 5 seconds, a

    di sound is given to remind you of releasing finger).

  • www.chinus.net CHINUS TECHNOLOGY

    Page 8

    2.3 Limited unlock: only managers can open the lock

    STEP Open the lock first.

    STEP After the lock is open, twist the lock handle downwards immediately or press down

    button . Dont release until 10 seconds pass (after 5 seconds, a di sound is given and

    another di sound is given after 10 seconds to remind you of releasing finger).

    STEP After hearing the second di sound, release hands or finger. The collecting

    window gets bright to remind you of inputting the managers finger.

    STEP Input the managers finger in the center of collecting window. If it succeeds, the

    collecting window will get dark. Only manager can open it next time.

    2.4 Lock from inside:

    Turn the deadbolt on the back panel to lock from inside. Under this status, fingerprint and

    password cannot open it from outside. Only emergency keys take effect.

    3. Password

    Apart from the fingerprint and emergency keys, password is also available to open the door.

    One manager password and one common user password can be set with two buttons. The

    alternate application of two buttons forms a 4-digit password.

    3.1 Unlock with password:

    STEP After the lock is electrified, press button to start. The collecting window

    turns bright and the green light glitters.

    STEP Input passwords (start with button , then input the password and end with

    button . The pressing times stands for the each figure of password. E.g. if the

    password is 1234, you must press button once1, press button twice2,

    press button three times3 and press button four times4.

    STEP Press button once to confirm.

    STEP If the password is correct, the lock will open and close in 3 seconds.

    3.2 How to set managers password

    STEP After the lock is electrified, press button to start. The collecting window

  • www.chinus.net CHINUS TECHNOLOGY

    Page 9

    turns bright and the green light glitters.

    STEP Press button down and dont release the finger until 10 seconds pass. (The

    red light glitters once after 5 seconds and it will glitter twice in all, with a di sound at the

    same time. After the red light glitters twice, release your finger. The collecting window is

    bright and the green light and red light glitter together).

    STEP The manager presses his registered finger once to confirm. If it succeeds, there will

    be 3 continuous di sounds and the green light glitters; if it fails, the red light turns bright

    and a di sound is emitted to remind you of inputting correct manager finger.

    STEP After confirmation, input password needed to be registered, (see the password

    input in last page for reference, start with button and end with button ).

    Press button once to confirm.

    STEP Repeat the last step and input the password again.

    3.3 How to set the password of common users

    STEP After the lock is electrified, press button to start. The collecting window

    turns bright and the green light glitters.

    STEP Press button down and dont release the finger until 5 seconds pass. (The

    red light glitters once after 5 seconds, with a di sound at the same time. After that, release

    your finger. The collecting window is bright and the green light and red light glitter together).

    STEP The manager presses his registered finger once to confirm. If it succeeds, there will

    be 3 continuous di sounds and the green light glitters; if it fails, the red light turns bright

    and a di sound is emitted to remind you of inputting correct manager finger.

    STEP After confirmation, input password needed to be registered, (see the password

    input in last page for reference, start with button and end with button ).

    Press button once to confirm.

    STEP Repeat the last step and input the password again.

    ATTENTIONS:

    All operation will terminate if no operation continues in 9 seconds.

    When it starts with low power, the red light will glitter and 3 di sounds will be given.

    It will give an alarm automatically in 5 seconds if it is prized or doesnt close well.

    The registration of common users must be under the authentication of manager.

    Power consumption is a little different according to different models.

    There is no initial password. Password can not be revised but to be covered by the new

    one. After complete deletion, all passwords are erased.

  • www.chinus.net CHINUS TECHNOLOGY

    Page 10

    SECTION 5: FLOW DIAGRAM

    Input password

    Press to start

    Input finger

    Door unlock

    Unlock with handle

    Lock closes in 3s

    Pass

    Unlock

    Delete finger

    Manager press finger

    Pressfor 10s

    Delete manager

    Delete common user

    Press finger

    Manager press finger once

    Pressfor 5s

    Press fingers

    position and

    press to confirm

    Pass

    Press to start

    Pass

    Delete finger

    Orientable

    Deletion

    Complete

    Deletion

    Deletion

    Press down

    handle or

    buttonfor 5s after lock

    opens

    Always unlock

    Lock Operation

    Limit unlock

    Only manager can

    unlock

    Always unlock

    Press down

    handle or

    buttonfor another 5s

    Normal status

    Manager press

    finger once

    Pass

    Limit unlock

    Press down

    handle or button

    for 10s after lock opens

    Registration

    Manager press

    finger once

    Pressfor 5s Pressfor 10s

    Registration of

    common users

    Twice inout the

    4-digit

    password to

    register the

    password

    Press finger 3 times

    Next registration

    Registration of

    managers

    Pass

    Press to start

  • www.chinus.net CHINUS TECHNOLOGY

    Page 11

    1

    2 3 4

    81112 10 9 7 56

    14 13

    SECTION 6: DOOR LOCK FITTINGS

    SECTION 7: DOORFRAME DRAWING

    No. Name &

    specification Quantity

    1 M3*10flat head

    bolt 1

    2 Battery case 1

    3 M5*60flat head

    bolt 4

    4 Back panel 1

    5 Front panel 1

    6 Round spring 2

    7 Foursquare stick 2

    8 Doorframe 1

    9 Lock body 1

    10 M4*30 bolt 2

    11 Bolt panel 1

    12 M4*6 flat head

    bolt 2

    13 M4*30 bolt 2

    14 Door bolt case 1

    In side door drilling Outsidedoor drilling

  • www.chinus.net CHINUS TECHNOLOGY

    Page 12

    Sheathe

    Foursquare

    stick

    SECTION 8: ATTENTIONS

    FINKIN Fingerprint locking devices are used by people with the need for a more

    secure working environment. To ensure a long lasting trouble free use of this

    product, please read the following cautions. Keep away from:

    Strong magnetism

    Strong radiation

    Salt

    Dampness

    High temperature

    Low temperature

    Direct sunshine

    1. FINKIN locking devices retain many characteristics of fingerprints. There

    are no pictures of them, so there is not a privacy problem.

    2. When used, your finger must not be too dry or too damp. If your finger is too

    dry, simply touch your forehead or nose to make a primary contact.

    3. Be careful to not scratch the fingerprint scanning window. Please keep the

    window clean by using a soft damp cloth. Do not use any type of abrasive

    cleaners as they will damage the scanning window.

    4. If the door is distorted or becomes warped, it will cause too much friction

    between the lock bolt trough and dead bolt case. So the locking device works

    properly, you will need to adjust the position of the lock trough and the dead

    bolt case.

    5. Beeping alarm will sound when battery is low on power, change to a new

  • www.chinus.net CHINUS TECHNOLOGY

    Page 13

    battery.

    6. Key can open door at any status.

    7. For security, every user should use more than two fingerprints.

    8. If there are complications on opening the door lock, contact the local

    distributor for assistance. Do not try to repair the fingerprint lock assembly.

    SECTION 9: FAQs

    QUESTION: Fingerprint lock works with batteries, so what should we do if the batteries fail?

    ANSWER: The lock is supplied by four AA alkaline batteries. The door lock alarm will sound

    automatically. Replace the old battery with new batteries. When the alarm is first sounds, you can

    use the door lock approximately 30 more times. You can have access through the door by key if

    necessary.

    QUESTION: My finger was injured or cut, how can I open the door?

    ANSWER: Normally small cuts will not restrict access, larger cuts will require you gain entrance

    with your passage key.

    QUESTION: Why is it necessary to input my fingerprint three times during programming of the

    lock mechanism?

    ANSWER: On registering the finger, our model needs 3 times to collect the fingerprint

    characteristics to ensure their accuracy, while when we open it, our model just compares the image

    with the collected characteristic. Therefore, once is enough.

    QUESTION: Why does the door not unlock with my registered finger?

    ANSWER: There are four basic reasons for this:

    a) The fingerprint used is not the finger recorded.

    b) Your fingerprint could be too dry or too damp.

    c) Finger was not pressed firmly enough on the scanning window, use additional pressure..

    d) The original fingerprint was not imprinted in the memory firmly enough and the system cannot

    identify it. It is best to use two fingerprints when programming, so there would be a back up.

    Re-program your fingerprint lock with new use prints.

    QUESTION: After I press button and press button for a few seconds, why cant I

    get into the process of fingerprint deletion?

    ANSWER: Before you press button , you may touch this button for a short time carelessly.

    In such a situation, the system needs passwords to continue. Therefore, you have to wait 9 seconds

    until the light extinguishes. If you want to delete fingerprints, please press button directly for

    5 or 10 seconds after operation starts.

  • www.chinus.net CHINUS TECHNOLOGY

    Page 14

    SECTION 10: REGISTER LIST

    User Position Light I.D. User Name New user name

    Manager

    01 Green

    bright red 1

    02 Green

    bright red 2

    03 Green

    bright red3

    04 Green

    bright red 4

    05 Green

    bright red 5

    Common

    users

    06 Green

    bright red 6

    07 Green

    bright red 7

    08 Green

    bright red 8

    09 Green

    bright red 9

    10 Green 1 red

    bright

    11 Green 1 red

    1

    12 Green 1 red

    2

    77 Green 7 red

    7

    78 Green 7 red

    8

    79 Green 7 red

    9

    80 Green 8 red

    bright

    Remarks:

    1. Above register is for fingerprint user access history to assist door lock administrator to add

    new users or to delete a user.

    2. 78 (Green 7 red 8) express: Green light will glitter 7times and red light glitter 8 times.

    80 (Green 8 red bright) express: Green light will glitter 8 times and red light keeps bright.

    Bright means the light is a steady bright light.