figure 13.1 a mercury droplet, shown here in cross section, steadily grows as mercury slowly flows...

12
Electrochemical Science and Technology: Fundamentals and Applications, Keith B. Oldham, Jan C. Myland and Alan M. Bond. © 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd. Figure 13.1 A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube.

Upload: lou

Post on 25-Feb-2016

26 views

Category:

Documents


0 download

DESCRIPTION

Figure 13.1 A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube. Figure 13.2 Simple electro-capillary curve at a mercury electrode. The simplicity of such a curve is often impaired by the presence of adsorbing species. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.1 A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube.

Page 2: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.2 Simple electro-capillary curve at a mercury electrode. The simplicity of such a curve is often impaired by the presence of adsorbing species.

Page 3: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.3 The relationship of capacitance to electrode potential according to three models of the double layer: those of Helmholtz, Gouy and Chapman, and Stern. The

following parameters were adopted: T = Tº, c = 10 mM, xH = 0.2 nm, εH = 6 10–11

F m–1, ε = 7 10–10 F m–1, A = 1 mm2, and Ezc = –230 mV versus SHE.

Page 4: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.4 Cartoon of the supposed structure of the interfacial region of a

double layer when the electronic conductor is charged negatively (left) or positively

(right). Only a small portion of the diffuse zone is shown.

Page 5: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.5 The potential, field, and charge density profiles according to the Stern model. A 10.0 mM aqueous solution of singly charged ions at 25.0ºC confronts an

electronic conductor bearing a positive charge of density 10.0 mC m–2. A permittivity of ε = 78.54 ε0 is assumed, except εH = 10.0ε0 in the compact layer, which has a width of

0.400 nm.

Page 6: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.6 Capacitance-versus-potential graphs, measured by a.c., for the Hg | 11000 mM KCl(aq) interface without and with 10 mM pentanol, revealing evidence of strong adsorption of the CH3(CH2)4OH molecules in the range –0.7 V < E < –0.1 V. At lower frequencies the sharp peaks become higher, while at high frequencies they disappear

because the changing electric field outruns the adsorption/desorption speeds.

Page 7: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.7 A linear potential-scan voltammogram for the oxidation of cytochrome-c peroxidase1326, a surface-confined reaction. The data relate to a monolayer coverage of

the enzyme on a graphite electrode, scanned at a rate of 20 mV s–1 in a phosphate buffer. The figure represents only the faradaic portion of the voltammogram. The much

larger non-faradaic current has been subtracted.

Page 8: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.8 The current-voltage curve when a platinum electrode is subjected to a slow triangular potential perturbation over the range 0.0 V ≤ E(t) ≤ 1.5 V in sulfuric acid. The

graph is illustrative only, because the detail depends on the scan rate, the acid concentration, the reversal potentials and particularly on the metallurgical and

electrochemical pretreatment of the platinum.

Page 9: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.9 A faradaic current badly contaminated by background.

Page 10: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.10 Neither I, the current through the faradaic element, nor E–ERE, the voltage across it, is directly measurable. The potentiostat’s ammeter measures Imeas = I+Inf, while

its voltmeter records the applied voltage ΔEappl = E –ERE – ImeasRu.

Page 11: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.11 Variation of Gibbs energy with the size of the nucleus. Though this diagram actually describes the formation of a liquid from a supercooled vapor1348, the

same principles apply to all metastable systems.

Page 12: Figure 13.1  A mercury droplet, shown here in cross section, steadily grows as mercury slowly flows from the supporting capillary tube

Electrochemical Science and Technology: Fundamentals and Applications,Keith B. Oldham, Jan C. Myland and Alan M. Bond.© 2011 John Wiley & Sons, Ltd. Published 2011 by John Wiley & Sons, Ltd.

Figure 13.12 Adsorption of “extra” ions causes a field that is sensed by the nearby field-effect transistor.