filterinsertreplacement_hdu27_cjc

1
Filter Insert Replacement CJC TM Fine Filter HDU 27/- Manufacturer: C.C.JENSEN A/S Løvholmen 13 DK-5700 Svendborg Phone +45 6321 2014 Fax +45 6222 4615 [email protected] www.cjc.dk PF1202 - 11.11.2009 Close valve on oil outlet Stop CJC TM Filter Close valve on oil inlet When filter housing is drained, unscrew top nut Lift off filter housing Remove used filter insert(s). Deposit according to national legislation Clean filter bottom. Place new CJC TM Filter Insert(s) Unscrew spring nut Remove spring and spring guide Tighten top nut with torque of 90 Nm Tighten spring nut with hand until contact with spring guide. Then tighten spring nut 4 turns per filter insert Replace O-ring for top nut Replace O-ring and place filter housing. If type 27/108, replace both O-rings FILTER INSERT REPLACEMENT 1 9 1 2 Pressure gauge Filter housing 3 Top nut 4 Automatic air vent/ Air vent screw 5 Spring nut 6 Spring guide 7 Filter insert 8 Filter bottom Power ON/OFF 11 Motor 10 Pump 13 Valve on oil inlet 12 Oil drain valve Valve on oil outlet 14 7 Filter insert 14 13 12 9 8 3 Replace O-ring 9 Open oil drain valve. Drain acc. to environ- mental precautions! Mount spring guide care- fully - make sure there is no contact between O-ring and thread Replace O-ring(s) 3 90 Nm 3 18 Automatic air vent: No action Air vent screw: Open screw 4 Automatic air vent Air vent screw 4 3 6 7 16 2 1 5 11 17 Be aware that oil spillage is a serious safety risk - keep clean! 6 7 7 5 12 13 9 8 7 10 X4 per insert 5 15 6 Replace O-ring for spring guide 14 If >1 insert type B, BLA or BLAT, use insert guide between filter inserts Automatic air vent: No action Air vent screw: Replace usit ring for air vent screw, and tighten with torque of 10 Nm 4 19 Replace usit ring Automatic air vent Air vent screw 10 Nm

Upload: vanecnr

Post on 03-Feb-2016

8 views

Category:

Documents


0 download

DESCRIPTION

cjc

TRANSCRIPT

Page 1: FilterInsertReplacement_HDU27_CJC

Filter Insert ReplacementCJCTM Fine Filter HDU 27/-

Manufacturer: C.C.JENSEN A/S • Løvholmen 13 • DK-5700 Svendborg • Phone +45 6321 2014 • Fax +45 6222 4615 • [email protected] • www.cjc.dk

PF1202 - 11.11.2009

Close valve on oil outletStop CJCTM Filter Close valve on oil inlet When filter housing isdrained, unscrew top nut

Lift off filter housing

Remove used filter insert(s). Deposit according

to national legislation

Clean filter bottom. Place new CJCTM Filter Insert(s)

Unscrew spring nut Remove spring andspring guide

Tighten top nut withtorque of 90 Nm

Tighten spring nut with hand until contact with

spring guide. Then tighten spring nut 4 turns per

filter insert

Replace O-ring for top nutReplace O-ring and place filter housing.

If type 27/108, replace both O-rings

FILTER INSERT REPLACEMENT

1

9

1

2Pressure gauge

Filter housing

3Top nut

4

Automatic air vent/Air vent screw

5Spring nut

6Spring guide

7Filter insert

8Filter bottom

PowerON/OFF

11Motor

10Pump

13

Valve on oil inlet

12Oil drain valve

Valve on oil outlet14

7Filter insert

1413

12

9

8

3

Replace O-ring

9

Open oil drain valve. Drain acc. to environ-mental precautions!

Mount spring guide care-fully - make sure there is

no contact between O-ring and thread

Replace O-ring(s)

3

90 Nm

3

18

Automatic air vent: No actionAir vent screw: Open screw

4

Automatic air vent

Air vent screw

43 6 7

16

21 5

11

17

Be aware that oil spillage is a serious

safety risk - keep clean!

6

7 75

12 1398

7

10

X4 per insert

5

15

6

Replace O-ringfor spring guide

14

If >1 insert type B, BLAor BLAT, use insert guide

between filter inserts

Automatic air vent: No actionAir vent screw: Replace usit ring for air vent screw, and

tighten with torque of 10 Nm

4

19

Replaceusit ring

Automatic air vent

Air vent screw

10 Nm