C O M PA N Y P R O F I L EHISTORY
MISSION STATEMENT
VISION
VALUES
REGISTRATION & CERTIFICATION
The story of Flow-Tek Valves & Controls Inc began more than 20 years ago, when
founder Mr. K.B. Patel decided to expand his existing machine shop to begin designing
and manufacturing control valves in Ahmedabad, India. He established his company with
a vision of commitment to quality and reliability.
Since its modest beginning, Flow-Tek Valves & Controls Inc has maintained that vision
while becoming a worldwide leader along with India in the valve industry.
To be recognized as one of the world's most trusted and innovative manufacturer of fire
protection equipments by providing our customers highest quality products that combine
performance and advance technology with value pricing achieving 100% customer
satisfaction.
Continue to offer customers top quality products to meet or exceed customer's needs.
We focus on:
Customer service - Product quality - Product design - Delivery reliability.
For more than 20 years, FLOW-TEK VALVES & CONTROLS INC Control Valves has
maintained a family-like atmosphere in the workplace that goes hand in hand
with family values.Company founder Mr. K. B. Patel had a mission to produce a quality
product in a quality work environment.
Today his son Mr. Hemal Patel and Mr. Jatin Patel continue that mission and uphold
several important values both in the workplace and among their client base
FLOW-TEK VALVES & CONTROLS INC is dedicated to quality, as evidenced by their
ISO Quality System, UL Listings, IBR Approvals, NSIC registered, CE.
The company is also dedicated to continual improvement, as proven by their in-house
continual improvement department and constant pursuit of new industry approvals.
ISO 9001:2008 SSI CERTIFICATE
IBR APPROVAL
CE CERTIFICATE
NSIC CERTIFICATE
UL CERTIFICATE FOR DELUGE VALVE
IEC CERTIFICATE
QUALITY POLICY
FACTORY ACT LICENSE
FPAI CERTIFICATE
The Automatic Control Valve, the word is self explanatory. It is a highly engineered Automatic Control Valve
knowledgeably designed to operate off line pressure or if desired, from an independent power source and
pilots. Flow age valves are hydraulically operated, diaphragm actuated for multi-function control of non
corrosive, nonabrasive fluids.
Size Range : 25mm to 500mm
Pressure Rating : Class 150 & 300
MAIN VALVE DESIGN
The main valve is Self Actuating Type, Pilot Operated, Globe/Angle Pattern, Top & Bottom Guided, Glandless,
Hydraulically Operated, and Diaphragm Actuated for multifunction control of less viscous, non corrosive, non
abrasive fluids.
Our wide range of control pilots makes it possible to offer combination models for variety of functions. The main
valves contain only one moving part. This simplicity of design promotes dependability, making the maintenance
easier and extend the life of the valve.
The lower portion of main valve diaphragm assembly is a mechanical check feature, which acts independently
of diaphragm position or pilot control system, and provide immediate check action when flow ceases.
MAIN VALVE CONSTRUCTION
The main valve consist only three major components; Body, Cover and the Top & Bottom Guided Diaphragm
Assembly which is the only moving parts in the main valve making the online maintenance very easy.
With simplicity of design & packless construction, minimum part wear is there which assure trouble free
operation & long life of dependable.
“Flow-Tek” is available in various materials and in full range of sizes with either threaded or flanged ends
MAIN VALVE OPERATING PRINCIPLE
The main valve is normally closed, when pressure is applied to the valve inlet the same pressure is applied to the bonnet also
(upper chamber) the valve remains close. By controlling the pressure in the bonnet the valve can be made fully open or
closed.
AUTOMATIC CONTROL VALVE
1
FULL OPEN
When pressure in the cover chamber is released to a lower pressure zone the line pressure at the valve inlet opens the valve
allowing full flow.
MODULATING ACTION
FLOW AGE valves are hydraulically operated, by introducing or releasing the liquid from above the diaphragm at controlled rates. A pressure
differential is required, either inlet to outlet or inlet to atmosphere, depending on application.
The control valve holds any intermediate position when operating pressures are equal above and below the diaphragm. The control pilot modulates
the valve to automatically compensate for line pressure changes.
SELECTION
By varying the pilots and piping arrangement this valve is able to perform a diversity functions and Application. Multiple function
performed by a single valve can result in added system protection and lower cost to user The main valve and pilot valve can be
services, without removing from the main pipe line
Valves are sized to provide an appropriate pressure drop for each application. The minimum pressure drop should be 5 psi for inlet to atmosphere and 10 psi from inlet to outlet.
“Flow-Tek” Valves are design for use with clean liquid (water, ATF) application for other media is possible, consult factory.
“Flow-Tek” is a single chamber full port engineered basic valve used in nearly all FLOW AGEs model bearing its description. when the main valve is provided with different combination of pilot & accessories the valve perform a wide range of Automatic Fluid Control making it a specified valve for the Municipal Water Works, Water Distribution System, Fire Protection, Irrigation, Industrial Petroleum & Aviation Fueling System, Marine Theme Park, Decorative Fountain etc. for the system application like Remote Control, Pressure Regulation, Solenoid Operation, Rate of Flow Control, Liquid Level Control, Check Function and many more.
Valve size range :- ½” to 20” for higher size
contact to factory
Exclusive quad seal – Retained on 3.5 + sides
Positive drip-tight closed
Longer Life span (Non edged seat)
Diaphragm Actuated (One moving part)
Hydraulically Operated (Frictionless)
Top and Bottom Guided Stem
Packless Construction (Less maintenance)
FEATURES : STANDARD PRODUCTION VALVES
UL LISTED Deluge Valve.
Digital Control Valve.
Pressure Reducing Control Valve.
Pressure Relief Control Valve.
Rate of Flow Control Valve.
Slow Acting Check Valve.
Level Control Float Valve.
Solenoid Control Valve.
Altitude Control Valve One Way Flow / Two Way.
Surge Anticipation Control Valve.
Digital Set Stop.
And many more function as per requirements.
FUNCTIONS
ACV FTV 100 (UL LISTED DELUGE VALVE)
Deluge systems are connected to a water supply through a deluge valve that is opened by the operation of a smoke or heat detection system. The detection system is installed in the same area as the sprinklers. When the detection system is activated water discharges through all of the sprinkler heads in the system. Deluge systems are used in places that are considered high hazard areas such as power plants, aircraft hangars and chemical storage or processing facilities. Deluge systems are needed where high velocity suppression is necessary to prevent fire spread.
VALVE SIZE : 50, 65, 80, 100, 150, 200, 250, 300 NB
UL APPROVED SIZE : 80, 100, 150 NB (50, 200 NB Under UL approval)
TRIMS : Wet Pilot Trims,
Dry pilot Trims,
Electric trim,
ACCESSORIES : Drain System Water motor gong.
Pressure Switch, Pressure Gauges and For
Pressure Control Pilot.
For more detail you can contact us :
AUTOMATIC CONTROL VALVE
2
PNEUMATIC OPERATED DIGITAL CONTROL VALVE
Diaphragm type Digital Control Valves, electro hydraulically operated by Diaphragm – self fluid actuated type having resilient (soft) seating for zeroleakage to leakage class VI as per ANSI FCI-70-2 (ANSI B16.104).They use FT-100 (Globe Straight) or FT-2100 (Globe - Y) Basic valve, which is a packless design, Top and bottom guided for vibration-free movement. The valve can be serviced without removing from the line. All Internal Parts are of complete stainless steel for very long life and corrosion-free. The body and cover are epoxy coated, inside and outside for smooth flow surface and longer life. These DCV can be used very commonly for white Oil having max. Viscosity up to 30 CST.
FT-113-40R & FT-2113-40R (DIGITAL CONTROL VALVE)
PISTON TYPE DIGITAL CONTROL VALVE
FIRE SAFE DESIGN, ACTUATOR OPERATED BALL CONTROL VALVE
COMPONENTS
1. BASIC VALVE
2. NEEDLE VALVE - ADJ. CLOSING SPEED
3. NEEDLE VALVE - ADJ. OPENING SPEED
4. 2-WAY SOLENOID VALVE - NORMALLY OPEN
5. 2-WAY SOLENOID VALVE - NORMALLY CLOSE
6. AIR FILTER REGULATOR
7. STRAINER - ‘Y’ TYPE
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
This model valve Maintain a constant level in storage tanks and reservoirs. Valve controlled flow into the rank is proportional to discharge flow keeping tank full.
Note:- the modulating float control valve is remote mounted. A stilling well around the float should be installed if the liquid surface is subjected to turbulence or wind Minimum differential pressure 5 psig Refer flow table for maximum flow Inlet pressure Vs tank head pressure
FT-110-10 MODEL FOR FLOAT (CONSTANT LEVEL CONTROL VALVE)
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
COMPONENTS
1. BASIC VALVE
2. FIG. 10-11 MODULATING FLOAT CONTROL
3. NEEDLE VALVE - ADJ. CLOSING SPEED
4. STRAINER - ‘Y’ TYPE
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
AUTOMATIC CONTROL VALVE
3
FT-116 MODEL FOR PRESSURE RELIEF / SUSTAINING CONTROL VALVE
Installed on a by – pass line, mainline pressure is accurately controlled By pressure relief of excess pressure. Installed in a mainline it prevents upstream pressure from dropping below preset minimum NOTE : Adjustment Range : 20-200 Psig Optional 0-30 Psi (100-300 Psig)
FT-113 MODEL FOR SOLENOID ON-OFF CONTROL VALVE
ON-OFF Valve operated by 2 way Solenoid, the main valve opens fully or closes drip tight depending upon the actuation position of solenoid, energized to open/energized to close. The valve may be remotely operated by times, relay, probed or any trigged device to the solenoid NOTE : Solenoid energized to open / closed optional) At the time of Order advice factory actual system working pressure for correct solenoid selection.
Solenoid selection : 110V AC / 220V AC / 24V DC as per requirement.
COMPONENTS
1. BASIC VALVE
2. FIG.15 REDUCING CONTROL
3. NEEDLE VALVE - ADJ. CLOSING SPEED
4. STRAINER - ‘Y’ TYPE
COMPONENTS
1. BASIC VALVE
2. 2-WAY SOLENOID VALVE (NC)
3. NEEDLE VALVE - ADJ. CLOSING SPEED
4. STRAINER - ‘Y’ TYPE
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
Standard :
Optional :
Quick sizing :
Points to be consider :
20 to 175 Psi
0-30 Psig ( 100-300 Psig) in SS control
Valve size one size smaller than line size
Check Maximum and Minimum Flow Check
pressure Drop-pressure reducing valve or
cavitations chart If valve size required to smaller
then line size then Consult flow tek representative
Factory
FT-115 MODEL FOR PRESSURE REDUCING CONTROL VALVE
Automatically reduces a higher Inlet pressure to a contact Lower outlet pressure regardless of changing flow rate And/or varying inlet pressure,
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
COMPONENTS
1. BASIC VALVE
2. FIG.16 RELIEF CONTROL
3. NEEDLE VALVE - ADJ. CLOSING SPEED
4. STRAINER - ‘Y’ TYPE
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
AUTOMATIC CONTROL VALVE
4
This model valve permits flow when inlet pressure exceeds Outlet pressure, Should pressure reversal occur the valve closes drip-tight opening and Closing speeds are separately adjustable Function can varying by changing flow control devises and tubing changing. TYPE : No Speed Control, NO closing speed, Opening speed maintain, separate opening and closing speed.
FT-118 MODEL FOR SLOW ACTING CHECK VALVE (OPENING / CLOSING SPEED CONTROL)
Provides automatic filling of elevated tanks or reservoirs. When the altitude control senses a drop in level below the predetermined set point the valve opens to fill tank. Supply pressure is greater then static head pressure. Discharge of the tank is by separate line or when altitude control senses below the predetermined set point of the valve opens to fill the tank, the valve opens the Discharge when the head pressure more than the supply pressure.
ADJUSTMENT RAGE : 5-20 FT 10-75 FT 50-200 FT
FT-127 MODEL ALTITUDE VALVE TWO WAY FLOW FOR ONE
COMPONENTS
1. BASIC VALVE
2. NEEDLE VALVE - ADJ. CLOSING SPEED
3. NEEDLE VALVE - ADJ. OPENING SPEED
4. CHECK VALVE
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
FT-114 MODEL FOR RATE OF FLOW CONTROL VALVE
Maintains a constant flow rate, adjustable, regardless of functions in the line pressure. The rate of flow pilot senses the differential pressure across the thin edge orifice plate mounted in the valve inlet flange. it responds to change the pressure and modulates the main valve to maintain the desired flow. Please Specify flows are at the time of order.
ADDITIONAL COMBINATION FUNCTION AVAILABLE : Rate of Flow / Solenoid ON-OFF.Rate of Flow / Pressure Reducing. Rate of Flow / Pressure Sustaining.
Points to be considered Orifice Plate sized as per application and per your acceptable pressure drop-please consult factory.
COMPONENTS
1. BASIC VALVE
2. FIG.16 RELIEF CONTROL
3. NEEDLE VALVE - ADJ. CLOSING SPEED
4. STRAINER - ‘Y’ TYPE
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
COMPONENTS
1. BASIC VALVE
2. FIG.27 ALTITUDE CONTROL
3. STRAINER - ‘Y’ TYPE
ACCESSORIES
1. LOCATED AS INDICATED
2. INCLUDED AS MARKED
X - ISOLATION COCKS
L - LIMIT SWITCH
P - POSITION INDICATOR
AUTOMATIC CONTROL VALVE
5
DESCRIPTION :
“FLOWAGE” MAKE Control Valve is a device capable of modulating flow at varying degrees between minimal flow and Full capacity in response to a signal from an external control device. The control valve, often referred to as “the final control element,” is a critical part of any control loop, as it performs the physical Work and is the element that directly affects the process.
PRINCIPLES OF OPERATION :
“FLOW-TEK” Control Valve is comprised of an actuator mounted to a valve. The valve modulates flow through movement of a valve plug in relation to the port(s) located within the valve body. The valve plug is Attached to a valve stem, which, in turn, is connected to the actuator. The actuator, which can be Pneumatically or electrically operated, directs the movement of the stem as dictated by the external Control device.
CONTROL VALVE
“FLOW-TEK” CAN OFFER GLOBE TYPE CONTROL VALVE :
Design
Flanges
F/F Distance
Leakage Class
ANSI B16.34
ANSI B16.5
ANSI B 16.10
ANSI B 16.104, ANSI-FCI-70
APPLICABLE STANDARDS
Model single seated, top guided valve with Quick Change Trims, designed for Economical service in wide Variety of application High valve co-efficient enables to handle Large flow rates with Low pressure Drop most widely used valve, for all major Fluids, Working conditions & Applications. Very easy to maintain. Valve size : ½” to 6” For valve size 8” and higher size consult factory Equal.
TRIMS : Equal percentage , Linear , Quick Opening, metering Pin.
MODEL NO : FT-729 (Single Seated, Globe, Unbalanced Design) Top guided,
CHARACTERISTICS :
TRIMS : Equal percentage , Linear , Quick Opening, metering Pin.
Model single seated, top and bottom Guided valve handle air, water, steam, gas, oil and other Fluids in process having tight shut off requirements top and bottom guided extends range of applications by Eliminating the side thrust effect of pressure drop across the plug, it can be used in throttling or On-Off service, it can be mounted in any position in the pipe line Valve size : ½” to 12”For valve size 14” and Higher size Consult factory.
MODEL NO : FT-714 (Single Seated, Globe) Top & Bottom guided
CHARACTERISTICS :
6
TRIMS : Equal percentage , Linear , Quick Opening, metering Pin.
Used for Thermic Fluid, Steam, Cooling Water, etc. Where excess amount of fluid has to be by-passed. 3-Way Valves are used for mixing two flows together, or for diverting a flow to or around a device (bypass). In order to produce consistent flow quantity for stable operation, the pressure drop across both flow paths(inlet to outlet) must be nearly equal. valve size : ½” to 6” for valve size 8” and Higher size Consult factory.
TRIMS : Equal percentage , Linear , Quick Opening, metering Pin.
CHARACTERISTICS :
MODEL NO : FT-715 (3 Way Mixing & Diverting) Skirt & Top Guided
Model single seated, control Valve accommodates air, water, steam, gas, oil and other Fluids in process in wide range of services condition simplicity Of valve body design and easy trim change out features coupled With high flow capacity result in lowered costs without sacrificing Quality owing to large relieving capacity of this model, Smaller size may be used thus reducing the investment and cutting pipe cost. valve size : ½” to 12” For valve size 14” and higher size consult factory.
TRIMS : Equal percentage , Linear , Quick Opening, metering Pin.
CHARACTERISTICS :
MODEL NO : FT-728 (Single Seated, Globe, Balanced Design) Cage Guided
Model single seated, control Valve accommodates air, water, steam, gas, oil and other Fluids in process in wide range of services condition simplicity of valve Model double seated, top and bottom Guided valve handle air, water, steam, gas, oil and other Fluids in process having tight shut off requirements Top and bottom guided extends range of applications by Eliminating the side thrust effect of pressure drop across the plug, Double seat construction permits control of higher differential pressure and Increase capacity of valve It can be used in throttling or on-off service, It can be mounted in any position in the pipe line valve size : ½” to 12” for valve size 14” and higher size consult factory design and easy trim change out features coupled With high flow capacity result in lowered costs without sacrificing Quality owing to large relieving capacity of this model, Smaller size may be used thus reducing the investment and cutting pipe cost. valve size : ½” to 12” For valve size 14” and higher size consult factory.
MODEL NO : FT-711 (Double Seated Globe) Top & Bottom guided
CHARACTERISTICS :
CONTROL VALVE
Quick
Ope
ning
Line
ar
Equal %
100
90
80
70
60
50
40
30
20
10
0
VALVE LIFT % OF FULL LIFT
FL
OW
% O
F M
AX
IMU
M C
V
Inherent Flow Characteristics Curves
0 10 20 30 40 50 60 70 80 90 100
7
in this category.
(1)DIRECT ACTING :
PNEUMATIC OPERATION : Two type actuators are available
ACTUATORS :
ACCESSORIES :
Bellow Sealed
Top/side Mounted Handwheel Operated
Electro-pneumatic Valve Positioner
Valve Posioner / I/P Convertor
Air filter Regulator
Air Lock
Limit Switches
Solenoid Valve
Pressure Transmitter
Temp. / Pressure Controller
Extended Bonnetï ï ï ï ï ï ï ï ï ï ï
Service
Controlled Fluid
Rate of Flow : Min, Max, Normal
Inlet And Out Let Pressure (psi)
Vapour Pressure (Liquids)
Critical Pressure (Liquids)
Temperature Operating And Maximum
Specific Gravity / Molecular Weight (Liquid / Gas)
Compressibility Factor (Gas)
Viscosity (Liquid)
Specific Weight (Steam)
Ratio Of Specific Heats (Gas And Steam)
Maximum Shut off Pressure (psi)
Should Valve Fail open or Close
ï ï ï ï ï ï ï ï ï ï ï ï ï ï
CONTROL VALVE
(2)REVERSE ACTING :
SPRING RANGE : Actuators are available using spring rates compatible with
valve and Trims size, actuator size and Process Conditions,
typical Spring range may be having approximately 12 or 24
psi spans Nominal air pressure to Diaphragm : 18 to 35 psi.
:PNEUMATIC / DIAPHRAGM ACTUATED :“Flow-Tek” Pneumatic Actuators are direct acting and utilize an air signal from an external control Device to create a modulating control action. The force of the air signal is received into the Actuator through a top port and distributed across the full area of the actuator's diaphragm. The Diaphragm presses down on the diaphragm plate and spring return assembly, which then moves the valve stem and plug assembly downward to stroke the valve. This actuator will move to a Stem-out position in the event of air signal failure. The choice of valve action (stem-In-To-Close or stem-In-To-Open) will determine its signal failure position.
8
Provides Air - to close action With
Direct Acting valve Plug or Air to
open action with reverse
acting valve plug.
Provides Air to Open action with
Direct Acting valve Plug or Air to
Close action with reverse Acting
valve Plug
LOCAL CONTROL :
ï
Watertight (IP68), Temporary submersible
Auxiliary limit switches
(Max 2 for each travel end)
Auxiliary torque switches
(Max 2 for each travel end)
Extended travel angle 0 0 0 0
(up to 120, 135, 180, 270)
Variation in torque and operating speed.
Explosion proof ( Ex d II B T4)
ICM1 FOR 1 & 3 Phase (Integral control Module) Main power : 3Ph / 220 / 380 / 440V AC : 1Ph / 110 / 220V AC.Control power : 24V DC, 5V DC.Magnetic selector switches: open / close & local / stop / remoteReversing electric contractors, transformer, phase detector.
: Potentiometer kit ( output signal : 0~1 kohm) High resolution potentiometer and precisely machined gearing are directly engaged with drive shaft to feedback continuous position of valve.
: Current transmitter (output signal : 4-20mA) Zero / span Adjustable (4 wire and 2 wire)
: Remote position controller (by input And output signal)
OPTIONS AVAILABLE / MECHANICAL :STANDARD SPECIFICATION :
: Weatherproof IP67, NEMA4 4x & 6,O-ring sealed, IP-68
: 110/220VAC/1Ph/50/60Hz, 380/440/VAC/3pH/50/60/Hz±10%, 24DC
: 110/220VAC/1Ph/50/60Hz,
: S4, 30~50%, 300~1200 start/Hour
: Squirrel Cage Induction motor
: 2 each for open and close (SPDT 250V AC / 10A rating )
: 1 each for open and close (SPDT 250V AC / 10A rating except INC 100)0 0 0 0: 90 ± 5 (0 ~ 100)
: Continuous mechanical indicator with arrow
: De-clutchable
: Provided by double worm gearing (no brake)
: 1 each for each travel end (open and close), external & adjustable
: 5W (110 / 220V AC) for anti condensation
: 2 - PF 3/4" TAP
: EP type grease
: Screw and lever Push type (Spring loaded)0 0 0 0
: Basic actuator :-20 C ~+ 70C C/W control option : -10 ~+ 60C
: 30% RH Max (Non Condensing)
: XVZ 10g. 02~34 Hz, 30 minutes
: Dry powder (Polyester)
Enclosure
Main Power Supply
Control Power Supply
Duty Cycle (on-off)
Motor
Limit switches
Torque Switches
Travel angle
Position Indicator
Manual Override
Self locking
Mechanical stopper
Space heater
Cable entries
Lubrication
Terminal Block
Ambient temperature
Ambient Humidity
Anti Vibration
External coating
POTENTIOMETER KIT
CURRENT TRANSMITTER
REMOTE POSITION CONTROLLER
REMOTE MOITORING AND CONTROL :
ï
ï
Compact and robust construction, Light weight providing high output torque (Max 9000Nm)
Wide range of Torque Variation (From min 100 Nm to max 9000 Nm)
Hard anodized aluminum housing inside and outside with external powder coated against various industrial environment.
Enclosure with radial seals & O-rings protection to weatherproof IP67 (NEMA 4 & 6 ) and optional water tight IP68.
Mounting base according to ISO 5211 standard.
Removable drive bush for easy machining and mounting.
Self - locking provided by double worm gearing (No brake required)
Auto - declutchable manual over ride hand wheel with pad lockable auto / manual switchable lever.
Reliable Mechanical Torque sensing system providing safe operation in overload condition.
Large size window indicator provides better position indication from a distance.
Various Local position control options providing easy commissioning and operation in field.
Digitalized control component.
ELECTRICAL OPERATION :
ELECTRICAL OPERATION :
ï ï ï ï ï ï ï ï ï ï ï ï
CONTROL VALVE
ELECTRIC ACTUATED :Electric Actuators are motor driven devices that utilize an electrical input signal to Generate a motor shaft rotation.
This rotation is, in turn, translated by the unit's linkage into a linear motion, which drives the valve stem and plug assembly for flow modulation. In case of electric signal failure, these actuators can be specified to fail in the stem-out, stem-in, or last position.
“Flow-Tek”
9
PRESSURE REDUCING VALVE
HIGH PRESSURE REDUCING VALVE
"Flow-Tek" FT-HP-32, FT-HP-35 is designed primarily for high pressure steam service commonly found in power plants, refineries, pulp and paper mills, and other high pressure process applications. Since high pressure superheated steam is routinely used for power generation (turbines), a pressure regulator capable...
"Flow-Tek" FT-LPRV, Balanced Plug Gas Pressure Regulator is the ideal valve for low pressure gas regulation with higher inlet pressures.The self-contained, low-pressure gas regulator is for use on tank blanketing, gas meter inlet pressure regulating, gas burners and other low-pressure air and gas applications. The valve has a 360° orientation, can be installed in any position, and can be easily repositioned while in line. The seat and plug can be inspected without removing body from the line.
FEATURES
FEATURES
Continuous un-perforated- diaphragm
Active Monitor Configuration Suitability
Size ranging from ½” to 2”
End connection options from ANSI 150# to ANSI 600# class
Tight shutoff capability
Easy online maintenance
Integral slam shut-off option with over pressure & under pressure cut-off
In-line maintenance-
Self-aligning plug-
Easy access to the seat for reduced down Stream. Ideal for
services where the valve is welded in lineGuided upper diaphragm plate, lower diaphragm plate and
stem ensures that the plug will stay centered in the seat
Stands up to the rigorous demands of high pressure services
for long diaphragm life
ï
ï
ï
ï
ï ï ï ï ï
ïï
ï ï ï
ï ï
LOW PRESSURE REDUCING VALVE
Inlet pressures up to 150 psi (10 bar)
Rugged, heavy-duty design allows emergency outlet pressure to
reachh 100% on inlet pressure without damaging valve
Completely Self-Operated - No external power source required
Soft elastomer plug provides ANSI Class VI shutoff
Easy to inspect and maintain - Seat and plug can be inspected
without removing body from the line
Completely self-operated. No external power source required
Wide range of low back-pressure settings - Choose from six pressure
ranges for set points ranging from 1” of WC. to 7 psi (3mbar to 0,5 bar)
Soft elastomer plug provides ANSI Class VI shutoff
"Flow-Tek" FT-1001 Self Acting, Pilot & Piston operated Pressure Reducing Valves are most popular for pressure reduction of STEAM in all types of Industries. The Valve operates on Spring Balance principle. The Downstream pressure is sensed below stainless steel diaphragm which is balanced by the spring tension. Increasing spring tension, increases outlet pressure and vice versa. The Valve has additional external Sense Line provision also, which improves performance and accuracy of outlet pressure.
FEATURES
High quality S. S. Diaphragm
Maintains Constant Outlet Pressure , irrespective to change in
Inlet Pressure (Pressure Drop is very low)
Suitable for Medium and Low Pressure (Steam, Gas, Air etc.)
Adjustable Spring (Wide range) for better pressure control
ïï
ï ï
PRESSURE REDUCING VALVE FOR STEAM
10
"Flow-Tek" is designed primarily for high pressure steam service commonly found in power plants, refineries, pulp and paper mills, and other high pressure process applications. Since high pressure superheated steam is routinely used for power generation (turbines), a pressure regulator capable...
FEATURES
ï
ï ï ï
ROBOTROL CONTROL VALVE
This design of pressure regulating valve is according to latest development and highly
in demand for accurate downstream pressure control. This is an ideal replacement of
self-regulating PRV where high flow & high accuracy are required.
No electric Connation or Control Supply required
Self-sense without let steam pressure, Air connection required.
Silent and very efficient valve
"Flow-Tek" FT-LPRV- Gas Back Pressure Regulator is the ideal valve for low-pressure gas regulation. The Mark 508 works in conjugation with the in a low-pressure tank blanketing valve system. LPRV can be used to vent gas from the tank to prevent the blanketing pressure from rising to a level that could damage the tank while maintaining a small, constant flow to keep the blanket fresh. During filling, It opens to allow gas to escape as the vapor space in the tank grows smaller. To size properly, find the rate of fill so that a regulator can be chosen based on it's ability to relieve the required amount of gas while sustaining desired blanketing pressure. The Mark 508 will also work well in any other type of low back-pressure gas application.
GAS BLANKETING VALVE
ï
ï ï
ï
ï
ï
FEATURES
Body rating up to 150 psi (10.3 bar)
Rugged, heavy-duty design - Emergency outlet pressure may reach 100% of inlet
pressure without damaging valve
360° body orientation - Valve can be installed in any position and easily repositioned
while in-line (3/4" - 8")
Easy maintenance - Seat and plug can be inspected without removing body from the
line (3/4" - 8")
Completely self-operated - No external power source required
Wide range of low back-pressure settings - Choose from six pressure ranges for set
points ranging from 1" of WC. to 7 psi (3mbar to 0,5 bar)
Tight shutoff - Soft elastomer plug provides ANSI Class VI shutoff ï
"Flow-Tek" FT-ACV-115 Pressure reducing & surge control valve automatically reduces a higher inlet pressure to a steady lower downstream pressure regardless of flow rate and inlet pressure fluctuations. Pilot valve enables the main valve to close quickly to prevent downstream surges.
FEATURES
ïï
ï
ï ï
LIQUID PRESSURE REDUCING VALVE
Automatically reduces a higher inlet pressure to a constant lower outlet pressure.
The valve consists of a main valve and a Fig. FT-15 pressure reducing control pilot.
Slight changes in downstream pressure acts on topside of control diaphragm causing
main Valve to counteract pressure changes and hold a constant outlet pressure.
The regulator will reduce the upstream pressure to a constant downstream pressure
regardless of the change in flow rates/or inlet pressure.
The pilot is a normally - Open valvethatsensesthedownstreampressure.
Sprin Range: Standard : 20175psig.Optional:5-35psig
11
PRESSURE REDUCING VALVE
TECHNICAL DETAILS
DESIGN TYPE
SIZE RANGE
STRUCTURE
MATERIAL
PRESSURE REDUCING VALVE FOR STEAM / HIGH PRESSURE REDUCING VALVE / LOW PRESSURE REDUCING
VALVE / GAS BLANKETING VALVE / GAS PRESSURE REGULATOR / LIQUID PRESSURE REDUCING VALVE
ROBOTROL CONTROL VALVE / PRESSURE REDUCING STATION / DESUPER HEATER / Gas & Liquid Meter Skids
15mm (1/2") to 300mm (12")
.
WCB, LCB,CF8, CF8M, Hastelloy, Inconel, Duplex Stainless Steel, …
more material on request available
13% Cr Steel, 304 , 304L, 316, 316L, 321, 347, F51, Monel
End Connection
Body
Trim
Flanged End to suit ANSI / DIN / BS / JIS / IS etc
APPLICABLE STANDARDS
Design Standard
Testing Standard
Face To Face
End Connection
Pressure – Temperature Chart
MFG STANDARD
API 598 / CONTROL VALVE ANSI-FCI-70-2-2006 STD
MFG STANDARD
Flanged End - ASME B 16.5 Butt Weld End – ASME B 16.25
ASME B 16.34
APPLICATION
Water works.
Power plants.
Sewage plants.
Process industries.
Chemical and petrochemical plants.
Steam Service
Air, Nitrogen, Natural Gas, Hydrogen and many other Industrial Gases. Sewage plants.
Petroleum industries
Aviation industries
Water works and sprinkler system
STEAM USE FOR HIGH PRESSURE STEAM LINE
Liquid service
ïïïï ï
ï
ï
ï
ï
ï
ï
ï
12
PRESSURE REDUCING VALVE
SAFETY VALVE
“Flow-Tek” Series FT-500 relief valves are intended for ASME section VIII steam service application and are furnished with a regular lifting lever and open cap as standard. The spring in FT-500-open bonnet design is exposed to atmosphere for cooling. Option accessories include a test-gag and governor ring as required by IBR (Industrial Boiler Regulation) in some cases.Special Inconel 725 disc is used for set pressure above 30 kg/cm2. Standard disc is SS316 and Nozzle of SS410 considering the steam up to temp. of 42c. Body/Bonnet are ASTM A216, Gr.WCB as standard up to temp. 420c. for steam temp. 420c. to 480c. WC6 Body, Bonnet is used and from 480c to 538c.-WC9 Body and Bonnet are used.
FEATURES
100% Compatibility to API 526
Single Trim (identical internal parts for steam/gas/liquids) allows economical maintenance
Quick delivery (2 - 4 weeks from the factory or next day from local warehouse)
Quick delivery for high-alloy materials
Longer valve lifespan due to hardened disc and (partially) satellited seat
Longer lifespan of optional bellows through integrated shielding
STEAM APPLICATION SAFETY VALVE
“Flow-Tek” FT 520series spring loaded pressure relief valve has been engineered to providing high quality cover pressure protection for Air, Gas, Vapors, Liquid and two phase application in an exceptionally rugged standardized design to the process and power industries. All valve casting and forging are manufactured to ASME/ASTM standard material specification. These are available in WCB/WC6/WCC/WC9/CF8/CF8M/CA15/Hastalloy-C/NACE MR0175 etc.High pressure valves will have Inconel Disc. And SS347H-Nozzle. Standard valves have SS316 Nozzle and Disc.
FEATURES
GAS SAFETY VALVE
Closed Bonnet and closed cap for general purpose service
Design of API 526/527 for all Nozzle Orifice from D through V
Single blow down ring for blow down adjustment
Packed lever available as optional (Prefix-'P')
Easily converted to any type of cap configuration.
Soft seat available for liquid application
Flange to ANSI/B16.5 as well as BS-10/PN
Chrome-Vanadium alloy steel springs as standard for 8.0mm and above wire dia
Full compliance with ASME Boiler and Pressure Vessel code section
VIII and API 526 and 527
Available in NACE standard MR0175 where application demands
LIQUID SAFETY VALVE
“Flow-Tek” FT 115 Pressure Relief, Sustaining or Backpressure Control Valve is designed to permit flow when upstream pressure is above the adjustable set point of the control pilot, and throttle toward closed when upstream pressure falls below the adjustable set point.When the valve is installed "off the main line" on the branch of a tee, it serves as a Pressure Relief Control Valve. It is normally closed, and quickly opens when upstream pressure exceeds the pilot setting, relieving excess pressure.When valve installed "in line" connecting two distribution zones, the valve acts as a Pressure Sustaining Control Valve. When pressure in the upstream zone falls below the pilot setting, the valve modulates toward a closed position, sustaining pressure in the upstream zone. When the valve is installed "in line" on the discharge of a pump, it acts as Backpressure Control Valve. When pump discharge
FEATURES
Auto Re-circulation on a refueled to control the pumping pressure of Air Crafts.
Solenoid Override or Pneumatic Override to safeguard the system. This can be operated remotely
to re-circulate full flow.
When installed in Main line, it prevents upstream pressure dropping below preset value.
When installed on a By-Pass line, it controls main line pressure by relieving excess pressure in
By-Pass/sump.
Ideal for pump by pass to protect the downstream equipment.
Relief pilot (F16) is normally closed due to spring tension.
With increase in upstream pressure above set value, Pilot (F-16) opens which makes Main Valve to
open fully.
Spring Range: Standard: 20-200 psig. Optional: 5-30
13
100% Compatibility to API 526
Single Trim (identical internal parts for steam/gas/liquids) allows economical maintenance
Quick delivery (2 - 4 weeks from the factory or next day from local warehouse)
Quick delivery for high-alloy materials
Longer valve lifespan due to hardened disc and (partially) stellited seat
“Flow-Tek” Series FT-300 used in very low pressure safety valve in many types of industries like Reactors, Vessels and Pipe line application.
FEATURES
WEIGHT & LEVER OPERATED SAFETY VALVE
100% Compatibility to API 526
Valve having lever and weight that can maintaining as much set pressure you required
FEATURES
THERMAL RELIEF VALVE
Flow-Tek Series FT-100 Screwed end and FT-110 Flanged End are used in Pharmaceutical Industries, Food and Beverages, Nuclear Chemical Reactors, Vessels and Pipe line application.
Specific application is also found on high pressure triplex plunger pump-where this is used to protect the over pressure occurrence on such type of pumps and pipelines.This is also widely used on air eliminator in loading terminals of petroleum products.
FEATURES
"Flow-Tek" Balanced Plug back Pressure Regulator is the ideal valve for excess pressure gas relief.The self-contained, low-pressure gas regulator is for use on tank blanketing, gas meter inlet pressure maintain, gas burners and other low-pressure air and gas applications. The valve has a 360° orientation, can be installed in any position, and can be easily repositioned while in line. The seat and plug can be inspected without removing body from the line.
BACK PRESSURE REGULATOR
Inlet pressures up to 150 psi (10 bar)
Rugged, heavy-duty design allows emergency outlet pressure to reach 100% on inlet
pressure without damaging valve
Completely Self-Operated - No external power source required
Soft elastomer plug provides ANSI Class VI shutoff
Easy to inspect and maintain - Seat and plug can be inspected without removing body
from the line
Completely self-operated. No external power source required
Wide range of low back-pressure settings - Choose from six pressure ranges for set
points ranging from 1" w.c. to 7 psi (3mbar to 0,5 bar)
Soft elastomer plug provides ANSI Class VI shutoff
SAFETY VALVE
Model FT-600 Close Bonnet Type Safety Relief Valves are designed for high pressure service these valves are suitable for saturated and superheated steam; Non-poisonous and non inflammable Gases and Vapours. Model FT-600 is a Closed Bonnet type Valve specially designed for poisonous and inflammable gases, vapours and liquids. These valves are available in 12 sizes as per API-526 Orifice sizes (EA-RA) and ANSI flanges covering set pressure ranging from 1.2 bar to 204 bar. A variety of materials are available to suit temperature ranges up to 550°C.
FEATURES
HIGH PRESSURE SAFETY VALVE
Design: API-526 & API-520 PART-1, ASME SECTION-1, VIIL IBR & NACE MR 0175
(2002 EDITION) Flange Drilling: ANSI B16.5, BS: 10, DIN, JIS STD.
Leakage Test: API-527
Material: ASTM STANDARD
14
SAFETY VALVE
“Flow-Tek” FT 620 series PILOT OPERATED pressure relief valve has been engineered to providing high quality cover pressure protection for Air, Gas, Vapors, Liquid and two phase application in an exceptionally rugged standardized design to the process and power industries.All valve casting and forging are manufactured to ASME/ASTM standard material specification. These are available in WCB/WC6/WCC/WC9/CF8/CF8M/CA15/Hastalloy-C/NACE Mr0175 etc.High pressure valves will have Inconel Disc. And SS347H-Nozzle. Standard valves have SS316 Nozzle and Disc.
FEATURES
PILOT OPERATED SAFETY VALVE
Pilot Operated Safety Valve:
Piping between the pilot and main valves is integrated into the cover to prevent damage
and freezing
Integrated Backflow Preventer as standard part
Four week delivery time from the factory
Higher capacity than comparable size with extra orifices
20% less installation space than competitors' comparable models
Supplementary Loading System:
Higher operating pressures are possible
Closing pressure difference of up to -3 %; opening process is independent of
back pressure
Functional test and valve adjustment possible during operation
Max. 0.1 sec. for valve to open completely
APPLICABLE STANDARDS
Design Standard
Testing Standard
End Connection
Pressure – Temperature Chart
API-520 , API-521, API-526, API-527, ASME SEC-VIII
API 527
Flanged End - ASME B 16.5 Butt Weld End – ASME B 16.25
E B 16.5 Butt Weld End – ASME B 16.25
ASME B 16.34
15
PRS with Control Valve
Pressure reduction for saturated & superheated steam with pneumatic control valve with PID control, which ensures high accuracy and fast recovery from disturbance in downstream pressure.
“Flow-Tek” We offer Pilot Operated Pressure reducing Station for Liquid Service. It is more efficient and economical to produce steam at high pressures ready for delivery through the distribution system. This may mean that the pressure needs to be reduced prior to the point of use or for different parts of the system. A reliable method of providing pressure reduction is to use a pilot operated pressure reducing valve station.
FEATURES
FEATURES
"Flow-Tek" We also offer pressure reducing stations with pressure control systems. High quality components are used which ensure reliability of the system. These are also engineered, designed and fabricated at FLOW TEK and duly hydro tested before dispatch. Note : Entire assembly is offered with IBR Certificate. PRS with Direct Acting Valve Assured accurate consistent downstream reduced pressure irrespective of fluctuations at inlet. Gives more latent heat, which is heat used in industrial equipment's resulting in lower fuel consumption.
FEATURES
PRESSURE REDUCING STATION
Designed as per best steam engineering practices
Assured accurate consistent downstream reduced pressure
irrespective of fluctuations at inlet
Safety valve sized for full discharge capacity of the PRS
Specially designed flow divider to ensure low noise levels
Rugged in design
Can be used in hazardous area without any certification
Operates even on low flow conditions
Fast response to pressure changes
Ready to install i.e. reduces installation time and field engineering
Maintenance free and user friendly
Both IBR Certified & Non IBR PRS are available
First time in India IBR approved bellow seal valves
Non IBR range also available
Available in the entire size range up to 250 mm NB
World class bellows from Germany
Zero maintenance valve
Bellow seal valves with multiple points of sealing ensures safe operation
Special integral stellited seat
Back seat arrangement as standard feature for all valves
Absolutely maintenance free and user friendly
Direct Acting PRV Self-acting, compact design to reduce the pressure of saturated steam. It can be offered with condensate pot.
Pilot Operated Pressure Reducing Station
Extremely accurate
No need for an external power source
Easy to adjust
16
Minimum straight length at outlet should be 4 mtrs.
Minimum distance of Temperature Sensor from the point of water injection should be 10 to 12 mtrs.
Water pressure should be minimum 7 bar more than the steam pressure.
Maximum recommended pressure difference between steam and water is 45 bar. If it exceeds
45 bar then install pressure control valve in waterline to reduce water pressure within limits.
Spray water should be very clean (equivalent to boiler feed water).
It is recommended to install a strainer of 0.8 mm mesh before water control valve.
Spray water should be very clean (equivalent to boiler feed water).
Instrument quality air is required.
Minimum controllable temperature is Saturation temperature + 7°C
Minimum inlet velocity should be 15mts/sec for FND and 7mts/sec for VND.
It is necessary to keep the steam flow rates (for max. and min conditions) as practical as possible.
Else the turndown ratio increases unnecessarily which necessitates the selection and use of a
combination of nozzles in the same spray cylinder
FEATURES
PRESSURE REDUCING STATION
Modular and compact design
No cooling water control valve required
Ultra-fine atomization
Patented nozzle design
Simple installation
High differential pressures possible
DESUPER HEATER
"Flow-Tek" Desuperheater leading suppliers of Steam Desuperheaters. We specialize in designing and manufacturing such equipment for power, process and co-generation plants.
STEAM DESUPERHEATERING The most practical way of reducing the superheat value of steam is by the direct addition of water. To achieve temperature stability of the conditioned steam and prevent thermal shock in downstream pipes, cooling water must be atomized. It is also necessary to have a correct mix of superheated steam and cooling water.
The potential to reduce the degree of outlet superheat is limited by the capability of control system. Almost all desuperheaters are used to reduce the steam (or gas) temperature as close to saturation as possible.
Most desuperheater models (types) are actually capable of achieving saturation or close to the saturation. The cavities that these units must be controlled precisely to prevent flooding of the whole system. The limitation of the control system is its sensitivity range. Consider a system with a controlled outlet temperature set at 1 °C above the saturation, where the controls are designed to maintain +/- 1 Deg.C.
The cooling water injection into the steam will continue till the temperature falls to saturation.. Then only the controls will reduce the cooling water injection. Due to the delays inherent in the control system (specifically introduction of derivative band) which is not in scope of desuperheater manufacturer, cooling water will continue to flow at the design rate for a short time. In that small amount of time, the saturated steam will be allowed to condense. Condensing vapor creates a vacuum, which sucks in more vapor, which too continues to condense. This results in loss of control, downstream equipment may be damaged & the downstream processes may be severely affected. Due to these reasons, we have opted to not guarantee DE superheating lower than 4 - 5 °C above the saturation. The downstream processes do not suffer much from such small amount of superheat.
EFFECTIVE DE SUPERHEATING
Recommendations for efficient working of DSH
17
"Flow-Tek" Gas & Liquid Meter Skids creating innovative fabrication solutions to address your unique applications, FLOW TEK Manufacturing builds made-to-order gas and liquid meter skids at our state-of-the-art facility in Ahmedabad. Flow tek's high-performance metering skids are constructed to match your flow rate requirements, and product benefits and options include:
FEATURES
PRESSURE REDUCING STATION
GAS & LIQUID METER SKIDS
High load capacityDurable, corrosion-free construction Negligible downtimeLow maintenance costs Full assembly on robust, steel framesNew and retrofitted designsCheck valves and security features
Flow tek valves engineers have built many of meter skid configurations for customers in theoil refinery, petrochemical and natural gas industries, and each design undergoes thorough
APPLICATION
Water works.
Power plants.
Sewage plants.
Process industries.
Chemical and petrochemical plants.
Steam Service
Air, Nitrogen, Natural Gas, Hydrogen and many other Industrial Gases. Sewage plants.
Petroleum industries
Aviation industries
Water works and sprinkler system
STEAM USE FOR HIGH PRESSURE STEAM LINE
Liquid service
18
CLIENTS LIST
TESTING FACILITY
PMI TEST
TYPE OF VALVES : FLANGE END VALVES
MAX TEST PRESSURE : 160 kg/cm.sq.
AIR : 6 kg/cm.sq.
SIZE : 2" TO 8" (CLASS 150 & 300)
SIZE : 2" TO 6" (CLASS 150,300 & 600)
AUTOMATIC CONTROL VALVE TEST BENCH
HYDRO BODY AND SEAT TEST BENCH
FULLY AUTOMATIC FUNCTION TEST BENCH AUTOMATIC CONTROL VALVE, PNEUMATIC CONTROL VALVE
TYPE OF VALVES : FLANGE END VALVES
SIZE : 2" TO 12" (CLASS 150 & 300)
Plot No. 172-173, Road - 4, G.I.D.C., Kathwada,Ahmedabad - 382 430. Gujarat, India.Phone : 079-2290 0219, 2290 0220.Mobile : +91 98240 80899, 98245 39702, 97251 04304E-mail : [email protected] / [email protected] : www.flowtekvalves.com, www.delugecontrolvalve.com
RANGE OF PRODUCT
KNIFE EDGE GATE VALVES
BALL VALVES
GATE VALVES
GLOBE VALVES
NON-RETURN VALVES
DIAPHRAGM VALVES
BUTTERFLY VALVES
STRAINERS / FILTERS
FLUSH BOTTOM VALVES
BLOW-DOWN VALVES
PLUG VALVES
FOOT VALVES
PULP VALVES
PINCH VALVES
SIGHT GLASS VALVES
MOISTURE SEPARATOR
STEAM TRAPE
RUBBER AND PTFE LINED VALVES
INDUSTRIAL VALVES
DELUGE VALVES AND SKID - UL LISTED
AUTOMATIC CONTROL VALVES
PNEUMATIC CONTROL VALVES
DIGITAL CONTROL VALVE
PRESSURE REDUCING VALVES
SAFETY VALVES & THERMAL RELIEF VALVE
PRESSURE REDUCING STATION AND
DESUPERHEATERS
AUTOMATION VALVES