fire management products...#cfs2-7/2014 fire management products fas track 1000 fas track bt 1000...
TRANSCRIPT
FIRE MANAGEMENT PRODUCTS
TECHNICAL PRODUCT GUIDE
DDA
FAS TRACK 1000
2 #CFS2-7/2014
WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.com
RE-THINK FIRE CAULKING:FAS Track 1000 requires NO fire sealant or fire spray when used on solid concrete construction or when used with spray applied fireproofing at fluted pan decks for 1 and 2 hour fire rated walls.
FAS Track costs up to 25% LESS than other brands claiming the same type of fire/acoustical/sound abatement.
With FAS Track 1000 you are guaranteed that once installed the intumescent tape will not wear off, tear off, or fall off, making it the most reliable intumescent track on the market.
On fluted deck applications mineral wool can be replaced with spray applied fireproofing, this assembly will not require any additional fire spray or fire caulking
CODE COMPLIANCEFAS Track 1000 meets current building codes and its unique profile design provides industry solutions for meeting deflection requirements where other materials or systems are restricted by design, compressibility, elasticity, or bond strength characteristics.
FAS Track 1000 has no restrictions providing 100% unencumbered movement. FAS Track 1000 has been tested for compliance with Section 713.3 of the 2009 and 2012 IBC and 2010 CBC and is listed with UL Underwriters Laboratories in accordance with:
n UL 2079: Tests for Fire Resistance of Building Joint Systems.
n ASTM E 1966: Standard Test Method of Fire Tests of Firestop Systems.
n ULC S115-M95: Standard Method of Fire Tests of Firestop Systems.
n ICC-ESR 2012 *Pending
n ASTM E-119 Standard Test Methods for Fire Tests of Building Construction and Materials
n Sound tested in accordance to ASTM E90-09
SEISMIC REQUIREMENTSFAS Track 1000 is approved for Class III cycling requirements, 500 cycles at 30 cycles per minute,meeting seismic building codes requirements. The class III movement provides design advantages over mastic reliant systems which are currently limited to class II (wind sway) capabilities of 500 cycles at 10 cycles per minute.
AIR LEAKAGE RATINGAir leakage tests conducted for compliance with Section 713.6 of the 2009 and 2012 IBC and 2010 CBC are witnessed by UL on conditions using FAS Track as the joint treatment established L-Ratings of less than 1 CFM per lineal foot. Any rating below 1CFM is also considered the best possible L-Rating. This is achieved with the FAS Track 1000 profile which provides a consistent sealagainst the drywall.
TECHNICAL ASSISTANCEFor technical questions and assistance please call 1.800.775.2362 or 1.800.416.2278. Email [email protected] or visit our website at www.marinoware.com
SOUND BENEFITS: Whether the protection you need is Fire, Air (Smoke), or Sound FAS Track 1000 is all the protection you need in one easy application.
Sound tests were performed at Western Electro-Acoustic Laboratory in Southern California to prove that the FAS Track 1000 profile will maintain maximum STC ratings without secondary acoustic sealant applications. In fact several sound tests were conducted with a ½” to ¾” open joint at the head-of-wall and with a sealed head-of-wall joint on the same wall assembly. Both open and closed joints rendered the exact same STC rating proving that no sound is lost through the open head of wall joint.
Sound tests were also conducted on a 2-1/2” wide stud double wall a.k.a. plumbing-wall or chase-wall with a single layer on both sides rendered an STC rating of 60. Adding one layer to only one side of the double wall increased the STC rating to 63.
The UBC requires Sound Transmission Class (STC) ratings and Impact Insulation Class (IIC) ratings for dwelling units, which include hotels, motels, apartments, condominiums, dormitories, and monasteries to be at a minimum 50 STC or IIC rating. Sound ratings can be greatly reduced through sound flanking paths. To reduce flanking paths drywall should be sealed tight to the framing member around the perimeter.
3
www.MarinoWARE.com
#CFS2-7/2014
Fire Management Products
FAS TRACK 1000
FAS TRACK BT 1000
FAS TRACK 1000 DL
FAS TRACK 1000 SLOTTED
FAS Track BT 1000 is a bottom track that offers fire and air (smoke) protection. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 18, 30 and 33 mils (25 and 20 gauges) with a minimum G40 coating complying with ASTM A1003.
FAS Track 1000 DL is a deflection track with ½” Intumescent Tape that offers fire and air (smoke) protection. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 (DW) 20 (STR) and 18 gauges (30, 33 and 43 mils) with a minimum G40 coating complying with ASTM A1003; and Grade 50 Type H for 50 ksi yield strength steel for 16 gauge (54 mils) with a minimum G60 coating complying with ASTM A1003. FAS Track 1000 DL has been tested with Underwritten Laboratories in accordance with UL 2079.
U.S. Patent #8,640,415
U.S. Patent #8,640,415
U.S. Patent #8,640,415
“A” Track Member Width (inch)
Flange Size (inch)
Length (ft)
Steel Thickness mils (gauge)
2 ½, 3 5/8, 4, and 6
1 ¼”
30 (20 DW), 43 (18), 54 (16)
10
“A” Track Member Width (inch)
Flange Size (inch)
Length (ft)
Steel Thickness mils (gauge)
2 ½, 3 5/8, 4, 6, and 8
2”
10
FAS Track 1000 Slotted is a slotted deflection track that offers fire and air (smoke) protection. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 (DW), 20 (STR) and 18 gauges (33 and 43 mils) with a minimum G40 coating complying with ASTM A1003; and Grade 50 Type H for 50 ksi yield strength steel for 16 gauge (54 mils) with a minimum G60 coating complying with ASTM A1003. FAS Track 1000 has been tested with Underwritten Laboratories in accordance with UL 2079.
30, 33, 43, 54 (20, 18, 16)
“A” Track Member Width (inch)
Flange Size (inch)
Length (ft)
“G” Steel Thickness mils (gauge)
2 ½, 3 5/8, 4, 6, and 8
2 3/4”
10
30, 33, 43, 54 (20, 18, 16)
Intumescent Tape both sides
Viper Trackwith hem.
1/2” Intumescent Tapeboth sides
A
( A )
( 1 1/4” )
1/2”
Intumescent Tape
90º
( A )
( G )2”
( 120” )
( G )
1/2”
( A )
2 3/4”
1 3/4”
1 1/4”
1”1” Typical
10’ length
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
4
www.MarinoWARE.com
Fire Management Products
FAS TRACK 1000 DETAILS (¾” JOINT PROTECTION FOR 1 & 2 HR. FIRE RATED WALLS)
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
HW-D-0518 1 & 2 HR. Standard Wall, Perpendicular to Fluted Deck
HW-D-0524 1 & 2 HR. Standard Wall, Parallel & Directly Under Deck Flute,
Configurations A & B
HW-D-0652 1 & 2 HR. Standard Wall, Cantilevered Under Beam
HW-D-0551 1 & 2 HR. Standard Wall, Centered Directly Under Beam
HW-D-0553 1 & 2 HR. Standard Chase Wall, Perpendicluar to Fluted Deck
HW-D-0620 1 & 2 HR. Standard Wall, Parallel & Directly Under
Fluted Deck (Config A.)
HW-D-0620 1 & 2 HR. Standard Wall, Parallel & Offset Under
Fluted Deck (Config. B)
HW-D-0554 1 & 2 HR. Standard Chase Wall, Concrete Slab
HW-D-0624 1 & 2 HR. Standard Wall, Concrete Slab -
Flat Tape & Joint Compound
WW-D-0104 1 & 2 HR. Vertical Tie In To Concrete Slab
BW-S-0024 1 & 2 HR. Bottom Of Wall - Static Joint
HW-D-0514 2 HR. Standard Wall, Perpendicular to Fluted Deck
HW-D-0550 2 HR. Standard Wall, Gypsum Wallboard Ceiling
HW-D-0573 2 HR. Standard Wall, @ Fluted Deck Beam Penetration
HW-D-0518 1 HR. PERPENDICULAR TO FLUTED DECK
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
FLUTED METAL DECKWITH CONCRETE FILL
MINERAL WOOL
METAL STUDBY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
HW-D-0518 2 HR. PERPENDICULAR TO FLUTED DECK
FLUTED METAL DECKWITH CONCRETE FILL
MINERAL WOOL
TYPICAL STEELFASTENERS BY DESIGN
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
HW-D-0524 1 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE
FLUTED METAL DECKFILLED WITH CONCRETE FAS STRAP
MIN. #6 FRAMINGSCREW BY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
CONFIGURATION “A”
HW-D-0514 1 HR. PERPENDICULAR TO FLUTED DECK*FLUTED METAL DECKWITH CONCRETE
SPRAY FIREPROOFING
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
38" NOMINAL GAP
(34" JOINT PROTECTION)
#8 x 1/2" FRAMING SCREW
METAL STUDBY DESIGN
*NOTE: SINGLE LAYER OF 58" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HR.
5
www.MarinoWARE.com
Fire Management Products
FAS TRACK 1000 DETAILS
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
HW-D-0524 1 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE
MINERALWOOL
FLUTED METAL DECKFILLED WITH CONCRETE
2" STRAP INSTALLEDBY DESIGNTYPICAL STEEL
FASTENERS BY DESIGN
MIN. #6 FRAMINGSCREW BY DESIGN
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
HW-D-0551 1 HR. CENTERED DIRECTLY UNDER BEAM
FIRE PROOFING ORMINERAL WOOL
STEEL BEAM
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
1/2" x 20 GA. Z-BAR OR16 GA. CRC @ BY DESIGN3/4" JOINT PROTECTION
5/8" TYPE"X" DRYWALL
#8 x 1/2" FRAMINGSCREW
FLUTED METAL DECK WITHCONCRETE FILL
FAS TRACK 1000
METAL STUDBY DESIGN
TYPICAL STEEL FASTENERSBY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
HW-D-0551 2 HR. CENTERED DIRECTLY UNDER BEAM
FIRE PROOFING ORMINERAL WOOL
STEEL BEAM
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
1/2" x 20 GA. Z-BAR OR16 GA. CRC BY DESIGN.
3/4" JOINT PROTECTION
5/8" TYPE"X" DRYWALL
#8 x 1/2" FRAMINGSCREW
FLUTED METAL DECK WITHCONCRETE FILL
FAS TRACK 1000
METAL STUDBY DESIGN
TYPICAL STEEL FASTENERSBY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
CONFIGURATION “B”
HW-D-0524 2 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE
MINERALWOOL
FLUTED METAL DECKFILLED WITH CONCRETE
2" STRAP BY DESIGNTYPICAL STEELFASTENERS BY DESIGN
MIN. #6 FRAMINGSCREW BY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
FAS TRACK 1000
CONFIGURATION “B”
HW-D-0524 2 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE
CONFIGURATION “A”
HW-D-0550 1 HR. GYPSUM WALLBOARD CEILING*
TYPICAL STEELFASTENERS BY DESIGN
*NOTE: SINGLE LAYER OF 58" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING. 2 LAYERS FOR 2 HR.
CONCRETE SLAB
OPEN WEB TRUSS ORJOIST
FURRING CHANNEL @24" O.C.
58" TYPE "C" GYPSUM
WALLBOARD
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
38" NOMINAL GAP
(34" JOINT PROTECTION)
#8 x 1/2" FRAMING SCREW
METAL STUDBY DESIGN
FLUTED METAL DECKFILLED WITH CONCRETE FAS STRAP
MIN. #6 FRAMINGSCREW BY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
6
www.MarinoWARE.com
Fire Management Products
FAS TRACK 1000 DETAILS
HW-D-0554 1 HR. CHASE WALL, CONCRETE SLAB
#8 x 1/2" FRAMINGSCREW
FAS TRACK 1000(TAPE ON FINISH SIDE ONLY)
5/8" TYPE "X"DRYWALL
METAL STUDSPACING BY DESIGN
CONCRETE SLAB
3/4" JOINTPROTECTION
DRYWALL SCREW1" LOWER THANTRACK LEG
HW-D-0554 2 HR. CHASE WALL, CONCRETE SLAB
#8 x 1/2" FRAMINGSCREWFAS TRACK 1000
(TAPE ON FINISH SIDE ONLY)
5/8" TYPE "X"DRYWALL
METAL STUDSPACING BY DESIGN
CONCRETE SLAB
3/4" JOINTPROTECTION
DRYWALL SCREW1" LOWER THANTRACK LEG
HW-D-0553 1 HR. CHASE WALL, PERPENDICULAR TO FLUTED DECK
#8 x 1/2" FRAMINGSCREW
FAS TRACK 1000(TAPE ON FINISH SIDE ONLY)
5/8" TYPE "X"DRYWALL
METAL STUDSPACING BY DESIGN
MINERAL WOOLFLUTED METAL DECKWITH CONCRETE FILL
3/4" JOINTPROTECTION
DRYWALL SCREW1" LOWER THANTRACK LEG
HW-D-0553 2 HR. CHASE WALL, PERPENDICULAR TO FLUTED DECK
#8 x 1/2" FRAMINGSCREW
FAS TRACK 1000(TAPE ON FINISH SIDE ONLY)
5/8" TYPE "X"DRYWALL
METAL STUDSPACING BY DESIGN
MINERAL WOOLFLUTED METAL DECKWITH CONCRETE FILL
3/4" JOINTPROTECTION
DRYWALL SCREW1" LOWER THANTRACK LEG
HW-D-0573 1 & 2 HR. FLUTED DECK BEAM PENETRATION*
MINERAL WOOL STUFFEDBETWEEN FRAMING ANDFIREPROOFING 50%COMPRESSED
(2) LAYERSDRYWALL
Z-CLIP
FAS TRACK 1000
METAL STUD
DRYWALL CUTAROUND I-BEAM WITH2" GAP
38" NOMINAL GAP
(34" JOINT PROTECTION)
I-BEAM
*NOTE: SINGLE LAYER OF 58" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING
FAS TRACK 1000
HW-D-0620 1 HR. PARALLEL & DIRECTLY UNDER FLUTED DECK
METAL STUDSPACING BY DESIGN
5/8" TYPE "X"DRYWALL
#8 x 1/2" FRAMINGSCREW
3/4" JOINT PROTECTION
FAS TRACK 1000
CONCRETE DECK
DRYWALL SCREW1" LOWER THANTRACK LEG
CONFIGURATION “A
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
7
www.MarinoWARE.com
Fire Management Products
FAS TRACK 1000 DETAILS
HW-D-0624 1 HR. CONCRETE SLAB
FAS TRACK 1000
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
CONCRETE SLAB
METAL STUDBY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
HW-D-0624 2 HR. CONCRETE SLAB
FAS TRACK 1000
5/8" TYPE "X" DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
CONCRETE SLAB
METAL STUDBY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
HW-D-0652 1 HR. & 2 HR. CANTILEVERED UNDER BEAM*FLUTED METAL DECK WITHCONCRETE FILL
1/2" x 20 GA. Z-BAR OR16 GA. CRC BY DESIGN
5/8" TYPE"X" DRYWALL
FIREPROOFING ORMINERAL WOOL
3.4 EXPANDEDRIB LATH
METAL STUDBY DESIGN
DRYWALL SCREW1" LOWER THANTRACK LEG
STEEL BEAM
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
FAS TRACK 1000
TYPICAL STEEL FASTENERSBY DESIGN
HW-D-0620 2 HR. PARALLEL & OFFSET UNDER FLUTED DECK
METAL STUDSPACING BY DESIGN
5/8" TYPE "X"DRYWALL
#8 x 1/2" FRAMINGSCREW
3/4" JOINT PROTECTION
FAST TRACK 1000
MINERAL WOOL
CONCRETE DECK
DRYWALL SCREW1" LOWER THANTRACK LEG
CONFIGURATION “B”
HW-D-0620 1 HR. PARALLEL & OFFSET UNDER FLUTED DECK
METAL STUDSPACING BY DESIGN
5/8" TYPE "X"DRYWALL
#8 x 1/2" FRAMINGSCREW
3/4" JOINT PROTECTION
FAS TRACK 1000
MINERAL WOOL
CONCRETE DECK
DRYWALL SCREW1" LOWER THANTRACK LEG
CONFIGURATION “B”
HW-D-0620 2 HR. PARALLEL & DIRECTLY UNDER FLUTED DECK
METAL STUDSPACING BY DESIGN
5/8" TYPE "X"DRYWALL
#8 x 1/2" FRAMINGSCREW
3/4" JOINT PROTECTION
FAS TRACK 1000
CONCRETE DECK
DRYWALL SCREW1" LOWER THANTRACK LEG
CONFIGURATION “A”
*NOTE: FOR 2 HR., 2 LAYERS 5/8” TYPE X ON BOTH SIDES.
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
8
www.MarinoWARE.com
Fire Management Products
FAS J-TRACK (SHAFT WALL) (¾” JOINT PROTECTION FOR 1 & 2 HR. WALLS)
The FAS J-Track provides the same great benefits of FAS Track 1000 within a shaft wall assembly.
• FAS J-Track has longer legs than standard J-Runner to provide greater deflection at the head-of-wall joint
• FAS J-Track provides ¾” overall unencumbered movement
• FAS J-Track provides the best possible L-Rating (smoke) for 1 and 2 hour fire ratings
• FAS J-Track eliminates the installation of fire caulking or additional drywall rips
FAS J-TRACK (Shaft Wall)
FAS J-Track is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 30 mil (20ga DW), 33mil (20ga STR) with a minimum G40 coating complying with ASTM A1003. FAS J-Track has been tested with Underwritten Laboratories in accordance with UL 2079 for shaft wall assemblies.
“A” Track Member Width (inch)
Flange Size (inch)
Length (ft)
Steel Thickness mils (gauge)
2 ½, 4, and 6
30 (20ga DW), 33 (20ga STR)
10
1 ½” short leg, 2 ½” long leg
Patent Pending
HW-D-0525 2 HR. PERPENDICULAR TO FLUTED DECK* HW-D-0525 2 HR. PERPENDICULAR TO FLUTED DECK*
FLUTED METAL DECKWITH CONCRETE FILL
MINERAL WOOL
TYPICAL STEELFASTENERS BY DESIGN
*NOTE: SINGLE LAYER OF 5 8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING
CH STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
FAS J-TRACK
38" NOMINAL GAP
(3 4" JOINT PROTECTION)
FLUTED METAL DECKWITH CONCRETE FILL
MINERAL WOOL
TYPICAL STEELFASTENERS BY DESIGN
*NOTE 1: SINGLE LAYER OF *NOTE 2: NO FIRE SPRAY REQUIRED
58" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING
CH STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
FAS J-TRACK
38" NOMINAL GAP
(3 4" JOINT PROTECTION)
CEMENTITIOUSSPRAY FIREPROOFING
WW-S-0061 1 HR. SHAFT WALL VERTICAL TIE IN TO CONCRETE SLAB WW-S-0061 2 HR. SHAFT WALL VERTICAL TIE IN TO CONCRETE SLAB
1" SHAFT LINER
34" JOINT
PROTECTION
CONCRETE
CH STUD
TYPICAL STEELFASTENERS BY DESIGN
FAS J-TRACK
MINERAL WOOL
58" TYPE "X"
DRYWALL
DRYWALL SCREW
34" JOINT
PROTECTION
CONCRETE
TYPICAL STEELFASTENERS BY DESIGN
FAS J-TRACK1" SHAFT LINER
CH STUD
MINERAL WOOL
58" TYPE "X"
DRYWALL
DRYWALL SCREW
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
9
www.MarinoWARE.com
Fire Management Products
FAS J-TRACK (SHAFT WALL) ¾” JOINT PROTECTION
HW-D-0622 2 HR. DIRECTLY UNDER BEAM* HW-D-0623 2 HR. PARALLEL & CANTILEVER UNDER BEAM*
STEEL BEAM
MINERAL WOOL ORSPRAY FIREPROOFING
CONCRETE SLAB OR FLUTEDMETAL DECK WITH CONCRETE FILL
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
1/2" x 20 GA. Z-BAR OR16 GA. CRC @ 16" O.C.
CT STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
MINERAL WOOL
38" NOMINAL GAP
(34" JOINT PROTECTION)
*NOTE: SINGLE LAYER OF 58" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING
FAS J-TRACK
CONCRETE SLABOR FLUTED METALDECK WITHCONCRETE FILL
STEEL BEAM
STRUCTURALFIREPROOFING(THICKNESS BY OTHERS)
EXPANDED METALLATH
1/2" x 20 GA. Z-BAR OR16 GA. CRC @ 16" O.C.
MINERAL WOOL ORSPRAY FIREPROOFING
CT STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
MINERAL WOOL
38" NOMINAL GAP
(3 4" JOINT PROTECTION)
*NOTE: SINGLE LAYER OF 58" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING
FAS J-TRACK
8"
HW-D-0625 1 HR. CONCRETE SLAB HW-D-0625 2 HR. CONCRETE SLAB
CT STUD
FAS J-TRACK
1" SHAFT LINER
MINERAL WOOL
CONCRETE SLAB
5/8" TYPE "X" DRYWALL
34" JOINT PROTECTION
CT STUD
FAS J-TRACK
1" SHAFT LINER
MINERAL WOOL
CONCRETE SLAB
5/8" TYPE "X" DRYWALL
34" JOINT PROTECTION
CONFIGURATION “A” CONFIGURATION “A”
CT STUD
FAS J- TRACK
1" SHAFT LINER
MINERAL WOOL
CONCRETE SLAB
5/8" TYPE "X" DRYWALL
34" JOINT PROTECTION
FLAT TAPE & JOINTCOMPOUND
FLAT TAPE & JOINTCOMPOUND OVERHALF ROUND BACKERROD (OPTIONAL)
HW-D-0625 1 HR. CONCRETE SLAB
CONFIGURATION “B”
HW-D-0653 2HR. FLUTED DECK BEAM PENETRATION*
MINERAL WOOL STUFFEDBETWEEN FRAMING ANDFIREPROOFING 50%COMPRESSED
(2) LAYERSDRYWALL
Z-CLIP
FAS J-TRACK
CT STUD
DRYWALL CUTAROUND I-BEAM WITH2" GAP
38" NOMINAL GAP
(34" JOINT PROTECTION)
I-BEAM
FAS J-TRACK
*NOTE: SINGLE LAYER OF 5 8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
10
www.MarinoWARE.com
Fire Management Products
FAS STRAP
HW-D-0524 1 HR. OFFSET & PARALLEL UNDER FLUTED DECK HW-D-0524 2 HR. OFFSET & PARALLEL UNDER FLUTED DECK
PATENT PENDING
Member Width Length Gauge(mils)
10 ½ ” 10’ 0” 20 and 16 GA* (30 and 54mil)
FAS STRAP SPECIFICATION
FAS Strap is a flat strap with 2 strips of 1/2” to 1 ¼” intumescent. This strap is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield strength steel for 20 (33 mils) with a minimum G40 coating complying with ASTM A924; and Grade 50 Type H for 50 ksi yield strength steel for 16 gauge (54 mils) with a minimum G60 coating complying with ASTM A924. The FAS STRAP is listed under Underwriters Laboratories for one and two hour head of wall fire rated wall assemblies.
#8 x 1/2" FRAMINGSCREW
FLUTED METAL DECKFILLED WITH CONCRETE FAS STRAP
5/8" TYPE "X" DRYWALL
1" NOMINAL GAP(2" JOINT PROTECTION)
SLOTTED TRACK
DEFLECTION DRICTANGLE - DDA(BOTH SIDES)
DRYWALL SCREW1" LOWER THANTRACK LEG
METAL STUDBY DESIGN
#8 x 1/2" FRAMINGSCREW
FLUTED METAL DECKFILLED WITH CONCRETE
DRYWALL SCREW1" LOWER THANTRACK LEG
FAS STRAP
5/8" TYPE "X" DRYWALL
1" NOMINAL GAP(2" JOINT PROTECTION)
SLOTTED TRACK
DEFLECTION DRIFTANGLE - DDA(BOTH SIDES)
METAL STUDBY DESIGN
CONFIGURATION “A” CONFIGURATION “A”
*Other Thicknesses Available
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
11
www.MarinoWARE.com
Fire Management Products
FAS STRAP
HW-D-0524 1 HR. SHAFT WALL, PARALLEL & DIRECTLY UNDER DECK FLUTE
HW-D-0524 2 HR. SHAFT WALL, PARALLEL & DIRECTLY UNDER DECK FLUTE HW-D-0524 1 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE
HW-D-0524 2 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE HW-D-0524 1 HR. SHAFT WALL, PARALLEL & DIRECTLY UNDER DECK FLUTE
CONFIGURATION “A”
CONFIGURATION “A”CONFIGURATION “A”
CONFIGURATION “A”CONFIGURATION “A”
CT STUD
SLOTTEDTRACK ORJ-RUNNER
DEFLECTION DRIFTANGLE - DDA
1" SHAFT LINER
1" NOMINAL GAP(2" JOINT PROTECTION)
MINERAL WOOL
5/8" TYPE "X" DRYWALL
FLUTED METAL DECKWITH CONCRETE
FAS STRAP
FLUTED METAL DECKWITH CONCRETE
FAS STRAP
CT STUD
SLOTTEDTRACK ORJ-RUNNER
DEFLECTION DRIFTANGLE - DDA
1" SHAFT LINER
1" NOMINAL GAP(2" JOINT PROTECTION)
MINERAL WOOL
5/8" TYPE "X" DRYWALL
FLUTED METAL DECKFILLED WITH CONCRETE FAS STRAP
MIN. #6 FRAMINGSCREW BY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
FLUTED METAL DECKFILLED WITH CONCRETE FAS STRAP
MIN. #6 FRAMINGSCREW BY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
FLUTED METAL DECKWITH CONCRETE
FAS STRAP
CT STUD
FAS J-TRACK
1" SHAFT LINER
1" NOMINAL GAP(2" JOINT PROTECTION)
MINERAL WOOL
5/8" TYPE "X" DRYWALL
HW-D-0524 2 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE
FLUTED METAL DECKFILLED WITH CONCRETE FAS STRAP
MIN. #6 FRAMINGSCREW BY DESIGN
TYPICAL STEELFASTENERS BY DESIGN
FAS TRACK 1000
DRYWALL SCREW1" LOWER THANTRACK LEG
5/8" TYPE "X"DRYWALL
3/4" JOINTPROTECTION
#8 x 1/2" FRAMINGSCREW
METAL STUDBY DESIGN
CONFIGURATION “A”
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
12
ARCHITECT SPECIFIED & CONTRACTOR PREFERRED
CONTRACTOR PREFERRED, ARCHITECT SPECIFIEDWith above ceiling space at a premium most projects carefully coordinate all the MEP’s into a very limited area. With little wasted space it makes it extremely difficult to properly install the fire protection at the head-of-wall and just as difficult to inspect. Therefore many head of wall conditions are not properly fire rated ultimately putting lives at risk. The DDA head-of-wall joint system allows the fire protection to be installed during the framing process before the MEP’s are installed while there is still access to the head of wall.
CODE COMPLIANCEDDA not only meets all current building code deflection requirements but it can also provide fire, smoke and sound protection for drift & lateral movement. DDA is the first of it’s kind to provide unencumbered movement in both vertical deflection and lateral drift movement in a joint system that utilizes fire spray over mineral wool on just one side of the wall.
DDA has no restrictions providing 100% unencumbered movement. DDA has been tested for compliance with Section 713.3 of the 2006 and 2009 IBC and 2007 CBC and is listed with UL Underwriters Laboratories in accordance with:
• UL 2079: Tests for Fire Resistance of Building Joint Systems.• ASTM E 1966: Standard Test Method of Fire Tests of Firestop
Systems.• ULC S115-M95: Standard Method of Fire Tests of Firestop Systems.• ICC ESR-2012
SEISMIC REQUIREMENTSDDA is approved for Class III cycling requirements, 500 cycles at 30 cycles per minute,meeting seismic building codes requirements. The class III movement provides design advantages over mastic reliant systems which are currently limited to class II (wind sway) capabilities of 500 cycles at 10 cycles per minute.
AIR LEAKAGE RATINGAir leakage tests conducted for compliance with Section 713.6 of the 2006 IBC and 2007 CBC are witnessed by UL on conditions using DDA as the joint treatment established L-Ratings of less than 1 CFM per lineal foot. Any rating below 1 CFM is also considered the best possible L-Rating.
TECHNICAL ASSISTANCEFor technical questions and assistance please call 866.545.1545 or email [email protected] or visit our website at marinoWARE.com
DDAUS Patent #8,595,999 B1 (Deflection Drift Angle) is a composite steel angle with intumescent tape factory applied to the inside leg of the steel angle. The DDA is a fire-rated accessory that when combined with slotted or deep leg track will offer 2” unencumbered movement at the head-of-wall joint in accordance with UL-2079 “Test for Fire Resistance of Building Joint Systems”. The 2-1/2” outside leg marked for proper identification. The section is fabricated from minimum 0.018-inch thick hot-dipped red galvanized steel complying with ASTM A653 having minimum G-40 coating.
BENEFITS:• The DDA provides a universal fit for any wall width, gauge, height,
radius, pitched, shaft wall or standard wall• Easy installation; DDA is tapped in to place over the leg of the
track, the ¾” leg is friction fit between the overhead structure and the web of the header track
• There is no need for mechanical fasteners the DDA’s friction fitprovides fire and smoke protection during both vertical andlateral drift movement
• The DDA comes in 10’ lengths with 10 per box up to 2”unencumbered movement with positive stud attachment DDA butt joints are over lapped
• When fire spray is required RectorSeal brand fire sprays are required on ONLY ONE SIDE of the wall
• Over 20 separate UL reports in accordance to UL2079 “Test for FireResistance of Building Joints”
• Maintains best possible LRating (smoke rating) and NO loss of STCsound ratings at headofwall joint
• Uses up to 75% less fire spray with the majority of the joint systemsrequiring no fire spray at all
• DDA and RectorSeal brand fire spray offer an industry bestsustainable-life warranty
• DDA and Rectorseal brand fire sprays and sealants are 100% made in the USA
• All Engineering Judgements utilizing fire spray or fire sealant are provided by RectorSeal
• For complete list of all UL joint system visit cemcosteel.com
Sound Benefits: Whether the protection you need is Fire, Smoke, or Sound, DDA will help you achieve your requirements. Sound tests were performed at Western Electro-Acoustic Laboratory in Southern California to prove that the DDA will maintain maximum STC ratings without secondary acoustic sealant applications. In fact several sound tests were conducted both with a ½” to ¾” open joint at the head-of-wall and with a sealed head-of-wall joint on the same wall assembly. Both open and closed joints rendered the exact same STC rating proving that nosound is lost through the open head of wall joint.
Unlike fire or acoustic sealants that will crack and split with minimal movement the DDA will provide protection for the most extreme real life conditions and allow your head-of-wall joint to freely move both lateral and vertically without ever compromising the sound (STC) rating.
Distributed by:
13
www.MarinoWARE.com
The standard Deflection Drift Angle (DDA) is a red ¾”x 2-1/2” steel/intumescent angle that will provide up to 2” unencumbered movement on the following UL reports:
HW-D-0514 – Perpendicular to Flutes (Spray Fireproofing Fill)
HW-D-0577 – Standard Wall Perpendicular to Fluted Deck
HW-D-0524 – Standard Wall, Parallel & Under Fluted Deck Configurations A & B
HW-D-0582 – Standard Wall, Parallel to Beam Assembly Under Fluted Deck
HW-D-0580 – Standard Chase Wall to Fluted Deck (DDA)*
HW-D-0579 – Standard Wall Off Centered Under Beam
HW-D-0652 – Standard Wall Cantilevered Under Beam
HW-D-0579 – Standard Wall Directly Under Beam/Slab Bypass at I-Beam
HW-D-0596 – Standard Wall at Concrete Stairwell Slab Bypass
HW-D-0620 – Standard Wall Parallel to Fluted Deck/Directly Under Flute Configurations A & B
HW-D-0583 – Standard Wall Fluted Deck Perpendicularto I-Beam Penetration
HW-D-0584 – Shaft Wall Perpendicular to Under FlutedDeck (DDA)*
HW-D-0524 – Shaft Wall Offset and Parallel to Under FlutedDeck Configurations A & B
HW-D-0622 – Shaft Wall Under Beam
HW-D-0653 – Shaft Wall Cantilever Under Beam
HW-D-0621 – Shaft Wall Concrete Slab Bypass
HW-D-0563 – Shaft Wall Parallel to Beam at Fluted Deck*
HW-D-0623 – Shaft Wall at Fluted Deck I-Beam Penetration
HW-D-0576 – Concrete Deck
HW-D-0585 – Shaft Wall at Concrete Deck
HW-D-0581 – Chase Wall at Concrete Deck*
Distributed by:
DDA US Patent #8,595,999
Fire Management Products
DDA
Intumescent Tape
*Detail not shown in catalog, refer to www.UL.com.
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
14
www.MarinoWARE.com
Fire Management Products
DDA-1
.625
1.250
.313 .059
.250
Per Customers Specifications
DDA-1 is a RED or BLACK 5/8” x 1-1/4” steel/intumescent angle that will provide1” unencumbered movement for standard walls and shaft walls as listed onthe following UL reports:
HW-D-0514 – Perpendicular to Flutes (Spray Fireproofing Fill)
HW-D-0515 – Concrete Slab*
HW-D-0518 – Perpendicular to Fluted Deck*
HW-D-0524 – Parallel to Flute (FAS Strap)
HW-D-0550 – Gypsum Wallboard Ceiling*
HW-D-0551 – Centered Under Beam*
HW-D-0553 – Chase Wall at Pan Deck*
HW-D-0554 – Chase Wall at Concrete Slab*
HW-D-0573 – Perpendicular I-Beam Penetration*
HW-D-0620 – Parallel to Flute directly Under Flute
HW-D-0652 – Cantilever Fireproofing Under Beam
HW-D-0525 – Perpendicular to Flute Shaft Wall*
HW-D-0623 – Beam Penetration at Shaft Wall
HW-D-0622 – Shaft Wall under I-Beam
HW-D-0653 – Shaft Wall Cantilever Under Beam
HW-D-0556 – Parallel to Beam*
HW-D-0585 – Shaft Wall at Concrete Deck
All DDA-1 details and UL reports can be found at www.marinoWARE.com
Distributed by:
DDA-1 US Patent #8,595,999
Intumescent Tape
*Detail not shown in catalog, refer to www.UL.com.
SCALE 1 : 2
SCALE 1 : 2SCALE 2 : 1
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
15
www.MarinoWARE.com
Fire Management Products
DDA (DEFLECTION DRIFT ANGLE) FOR FLUTED PAN DECK APPLICATIONS
HW-D-0514 DDA-1, DDA DDA-1, DDA
DDA DDADDA DDA
HW-D-0577
HW-D-0524-A
HW-D-0524-B HW-D-0524 SHAFT WALL
HW-D-0576
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK
CT STUD
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK
DDA DDA
Distributed by:For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
16
www.MarinoWARE.com
Fire Management Products
DDA (DEFLECTION DRIFT ANGLE) FOR FLUTED PAN DECK APPLICATIONS
HW-D-0620-A
HW-D-0583
HW-D-0579 HW-D-0582
HW-D-0585
HW-D-0596
MARINOWARE SLOTTEDTRACK WITH DDA
MARINOWARE SLOTTEDTRACK
CT STUD
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK WITH DDA
DDA DDA
DDA DDA
DDA DDA-1, DDA
Distributed by: For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
17
www.MarinoWARE.com
HW-D-0653
HW-D-0622 HW-D-0623
HW-D-0621HW-D-0620-B
HW-D-0652
STEEL BEAM
CEMCO DEFLECTIONDRIFT ANGLE - DDA
SPRAYFIREPROOFING
CONCRETE SLAB OR FLUTEDMETAL DECK WITH CONCRETE FILL
STRUCTURAL STEELFIREPROOFING(THICKNESS BY OTHERS)
1/2" x 20 GA. Z-BAR OR16 GA. CRC @ 16" O.C.
CT STUD
5/8" TYPE "X" DRYWALL1" SHAFT LINER
MARINOWARE SLOTTEDTRACKMINERAL WOOL
1" NOMINAL GAP(2" JOINT PROTECTION)
MARINOWARESLOTTEDTRACK
MARINOWARE SLOTTEDTRACK
MARINOWARE SLOTTEDTRACK WITH DDA
CT STUD
MARINOWARE SLOTTEDTRACK WITH DDA
MARINOWARE SLOTTEDTRACK WITH DDA
CT STUD
CONCRETE SLAB ORFLUTED METAL DECKWITH CONCRETE FILL
CEMCO DEFLECTIONDRIFT ANGLE-DDA
CT STUD
5/8" TYPE "X" DRYWALL
1" SHAFT LINER
MINERAL WOOL
5/8" NOMINAL GAP(1 1/4" JOINTPROTECTION)
MARINOWARE SLOTTEDTRACK WITH DDA
DDA-1, DDA DDA
DDA-1, DDA DDA-1, DDA
DDA-1, DDA DDA-1, DDA
No longer are shaft wall assemblies the most difficult head-of-wall condition to protect from dynamic fire ratings. The DDA can be used with standard J-Runner track or slotted track for joints that require greater movement. The DDA provides the most economical solution for shaft wall assemblies with dynamic movement as the DDA is installed only on the finish side of wall. There is NO fire sealant required above the shaft liner. The majority of the UL head-of-wall joint systems do not require any fire spray and the DDA allows the shaft wall to be built from one side as intended.
Distributed by:
Fire Management Products
DDA: SHAFT WALL ASSEMBLIES
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
18
www.MarinoWARE.com
Fire Management Products
FAS-093X
Distributed by:
FAS-093X
SCALE 1 : 2
• NO Drywall Rips Required
• NO Fire Sealant Required
• NO Mineral Wool Required
12"
14"
14"
WW-D-0172
.578
R.030 R.030
R.030
.938
.072 .122 .478
SCALE 2 : 1
US Patent 8,671,632
FAS-093X Fire Rated control joint is a composite control joint with intumescent tape factory applied to the back side of the control joint. The FAS-093X has been tested according to UL-2079 “Test For Fire Resistance of Building Joint Systems” and is used to relieve stresses of expansion and contraction of drywall interior partitions or ceilings running in a horizontal or vertical direction. The opening is protected by an orange plastic tape to indicate the fire rating this tape is removed after joint compound has been applied and the finish is completed. The section is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 Ksi yield strength steel 13 mil thickness.
2000
For assistance, please contact Marino\WARE at 800-627-4661 or visit www.MarinoWARE.comThis technical information reflects the most current information available and supersedes any and all previous publications effective July 31, 2015.
19
www.MarinoWARE.com
FAS Track™ and DDA™ represent an environmental advancement for interior partition construction. Their resilient intumescent layer of Blaze Seal makes it a one-piece solution to acoustical and fire resistive head assemblies. FAS Track and DDA’s partition head assembly eliminates most bridging, elastomeric sealants, mineral wool, and the need to cut drywall to fit the flutes of decking. FAS Track and DDA reduce scraps and waste and often does not require any sealant to be applied to the head of wall joint. Resources are saved, and indoor air quality is improved.
FAS Track and DDA contribute to a number of LEED credits in the 2009 New Construction, Core and Shell, Commercial Interiors, and Schools rating systems.
RESOURCE CONSERVATION: Because even very short pieces of FAS Track and DDA are used in construction, very little is wasted. Scraps as small as 16 inches are often retained. The metal portion of smaller scraps can be recycled, once the BlazeSeal is peeled off by hand. For projects with high targets for MR 2 Construction Waste Management, this method of recycling FAS Track and DDA scraps will contribute to this credit.
MR CREDIT 4 RECYCLED CONTENT: FAS Track and DDA contributes 32.7% recycled content to this credit.
IEQ 3.2 INDOOR AIR QUALITY MANAGEMENT PLAN – BEFORE OCCUPANCY: If the Air Testing option is selected by the project team, FAS Track and DDA are valuable players in achieving this credit. FAS Track and DDA eliminate the need for spray-applied smoke seal and elastomeric fire sealant. They also can take the place of acoustical sealant in some assemblies. With no solvents and very low VOC content, FAS Track and DDA significantly reduce indoor air pollution. The Air Testing option is difficult to achieve, and every bit of indoor pollution that FAS Track and DDA eliminate from the project increases the chances of success.
IEQ 4.1 LOW-EMITTING MATERIALS – ADHESIVES AND SEALANTS:FAS Track and DDA’s intumescent fire-resistive seal is a solid, factory-applied layer, so it is not required to comply with the Adhesives and Sealants VOC limits. Moreover, because BlazeSeal provides all the fire protection required for many partitions, no spray-applied smoke seals or elastomeric fire-resistive sealants are required, so their VOC contributions are eliminated.
IEQ 4.6 LOW-EMITTING MATERIALS – CEILING AND WALL SYSTEMS (LEED FOR SCHOOLS): This credit does not apply to FAS Track and DDA. Only the gypsum board and the wall coverings are required to be tested.
IEQ 9 ENHANCED ACOUSTICAL PERFORMANCE (LEED FOR SCHOOLS): FAS Track and DDA improve the Sound Transmission Class (STC) of partitions, and can even eliminate the need for acoustical sealant at the head of partitions. Its resilient BlazeSeal layer helps damp sound transmission of partitions around core learning spaces and can help achieve this credit.
For other LEED credit contributions, see www.cemcosteel.com and click “LEED Certification”.
If you have any questions, concerns, or clarifications, please contact our Technical Services Department at (800) 627-4661 or www.marinoWARE.com.
FAS TRACK AND DDA’S ENVIRONMENTAL BENEFITS AND LEED CONTRIBUTIONS
20 #CFS2-7/2014
www.MarinoWARE.com
For more information, please contact Marino\WARE® Technical Services at 866-545-1545 This technical information reflects the most current information available and supersedes any
and all previous publications effective July 31, 2015 #CFS2-7/2015© 2015 Ware Industries, Inc. All rights reserved