FIRE GUARD has been developed indigenously by our R & D Engineering conforming to BS - 2189 standards and manufactured by us to withstand Indian conditions for longevity of life-span for uninterrupted service. Besides being most-economical, it has the following features for an automatic functioning:
Automatic detection of smoke or fire.
Automatic sounding of local alarm inviting attention of nearby available persons to extinguish fire by using fire extinguishers/ equipment kept in the premises.
Auxiliary relay contact for activation of peripheral equipments likeAuto Dialer, Auto Flooding System, Power Off etc.
l
l
l
Automatic Fire Detection & Alarm System
Electronic Security Solutions
E.R.T.L. Tested
FG-04
Fire GuardFIRE
Fire Alarm Systems
![Page 2: Fire+Guard+with+DI-FIRE+logo](https://reader036.vdocument.in/reader036/viewer/2022080223/55cf94dc550346f57ba4ee22/html5/thumbnails/2.jpg)
l
l
l
l
l
l
l
l
l
Features And Specification As Per BS: 2189 - 1988
Full Featured Built In Testing Facility
Four Zone With Plug-In Card For Easy Servicing
Fully Protected Power Supply With Built In charger
Supports All Type Of Smoke And Heat Detectors
Built In Noise Reduction Circuit For Avoiding False Alarm
Full Featured Fault Annunciation System With Ack. & Reset
Facility
Proven Field Tested Design
High MTBF
SPECIFICATION
ELECTRICAL
PROTECTION
AUDIO-VISUAL ALARM
INPUT
OUTPUT
TESTING
PHYSICAL
ENVIRONMENTAL
lllllll
l
l ll
l ll ll ll l
l
ll
l
ll
l
ll
Supply Voltage : 230 Volt ± 10 % A.CBattery Backup : 24 Volt, 7 Ah (External)Battery Charger : Constant CurrentSystem Voltage : 24 VoltEnd Of Line Resistance : 4K7 OhmOpen Detection Threshold : > 91.1% Of System VoltageFire Detection Threshold : > 10.8% And < 51.0% Of
System VoltageShort Detection Threshold : < 10.8% Of System Voltage
A.C Fuse : 1.0 Amp. D.C Fuse : 2.0 Amp.Battery Fuse : 5.0 Amp.
A.C Fail D.C FailCharger Fail Battery OpenBattery Low Zone IsolationZone Input Short Zone Input Open
Maximum 25 Sensors In Each Zone (Two Wire)
For Hooter (24 Volt, 2 Amp Max.)Aux. Relay Change-Over Contact
Full Featured Testing Of All Zones For Simulated Fire, Open and Short
Colour : RedEnclosure : 16 Gauge Cold Rolled Steel
SheetDimensions : 310mm x 295mm x 165mm
Operating Temp. : 0°C to 55°CMax. Humidity : 95% non condensing
IonizationSmoke Detector
Optical Smoke Detector
Alarm
Auto Dialer / Other Auxiliary Devices
Telephone Network
ManualCall point
ResponseIndicator
ROR Detector
INPUT
OUTPUT
APPLICATION DIAGRAM
digitals india security products pvt. Ltd.[An ISO 9001:2000 Company]
Corporate Office:
:
C-2, First Floor, Sector - 10, Noida - 201301 [U.P.] INDIA
Tel.: 0120 - 2539550, 4275850, Fax: 4320751, E-mail: [email protected] Mumbai Delhi & NCR Bangalore Kolkata Secunderabad Ahmedabad
Jalandhar Cantt. Lucknow Varanasi Patna Bhopal Indore Jabalpur Raipur Ranchi
Our Pan-India Presence
n n n nn n
n n n nnnn n n
www.digitalsindia.com www.disvu.netn