Nursecall: by Tunstall
SystemDescription
Flamenco®Nursecall: by Tuns
00 8812 64
The manual was prepared with due care, and all details were checked for their correctness. However, we cannot assume any responsibility form possible discrepancies or incomplete information.
All rights to this documentation are reserved, in particular copyright and distribution rights. No part of this documen-tation may be reproduced in any form or processed, copied or distributed using electronic systems without the prior written consent by Tunstall GmbH.
We reserve the right for implementing technical changes.
© Tunstall GmbH
1. Table of Contents
1. Table of Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. Performance features . . . . . . . . . . . . . . . . . . . . . . . . . . . 32.1 Flamenco nurse call systems are … . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 Sample ward . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73.1 Presence message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Call types and call categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Signalling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.4 Consoles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.5 Call handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.6 Speech communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.7 Rooms without speech communication. . . . . . . . . . . . . . . . . . . . . . . . . 24
4. Interfaces - OpenConcept . . . . . . . . . . . . . . . . . . . . . . . . 254.1 Interfaces in rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.2 Interfaces at group bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.3 Interface at the central control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5. Organisational modes . . . . . . . . . . . . . . . . . . . . . . . . . . . 315.1 Ward operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.2 Ward coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.3 Central call handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.4 Zone nursing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.5 Room nursing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6. Configuration / SystemOrganizer . . . . . . . . . . . . . . . . . . 376.1 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6.2 System planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.3 Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7. The technology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397.1 System structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.2 Control unit OSY-ControlCenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
7.3 Speech communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
7.4 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
7.5 Wards and groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
8. System safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458.1 Partial system failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8.2 Failure of coupled systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8.3 Fail safe acc. to DIN VDE 0834:2000 . . . . . . . . . . . . . . . . . . . . . . . . . . 45
8.4 Failure of the electric power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 1
1. Table of Contents
8.5 Differentiated indication of fault location . . . . . . . . . . . . . . . . . . . . . . . . 46
9. Room types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 479.1 Patient room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
9.2 Function room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
9.3 Ward bathroom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
9.4 Nurse station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
9.5 Corridor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
9.6 Back boxes, connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
9.7 Cable legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
10. Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7310.1 Signal lamps, corridor displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
10.2 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
10.3 Room terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
10.4 Connection sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
10.5 Patient units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
10.6 Call handling consoles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
10.7 System software and PC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
10.8 TV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
10.9 Supplementary system components . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
10.10 Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
10.11 System control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
10.12 Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
10.13 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
10.14 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
11. Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
2 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
2. Performance features
2.1 Flamenco nurse call systems are …
2.1.1 … simple
Standard cables and back boxes.
Plug-and-Play components.
Products are robust, easy to clean.
Simple 3-step mounting.
Wire-saving installation.
Utilisation of current wiring nets possible.
Group bus (OSYnet) and room bus (RAN).
2.1.2 … safe
Safety acc. to the applicable regulations, e.g. DIN VDE 0834:2000.
Hierarchic fail-safe principle with safety concept.
System platform safe to operate independent from other networks.
Autonomous working basic system.
Function monitoring with fault location display.
2.1.3 … a speech system
Speech communication to all rooms and sections in the building.
Excellent speech quality.
Various ward consoles ComStation available.
PC based ManagementCenter for central call handling.
2.1.4 … intelligent
Individual system layout.
Free forming of wards, nursing units and organisational sections even across the constructional limits of a ward.
Free selectable organisational mode can be changed by staff on site at any time according to the nursing requirements.
2.1.5 … easy to configure
Planning and configuration of the whole system using a planning and configura-tion tool (SystemOrganizer).
System configuration of all relevant parameters by a hospital technician.
Complete system access via remote access.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 3
2. Performance features
2.1.6 … open
Many interfaces for foreign systems (patient data, alarm systems, telemetry ap-plications, facility management...).
Full integration of telephony applications (analogue, ISDN, VoIP, WLAN ...).
Compatibility with earlier systems EccoLine and NewLine.
Use of display units (e.g. corridor displays) even for messages from not-nurse-call-applications.
No integration of quick changing technologies such as PBX. Instead of that con-necting these devices via interfaces making an independent change of the single solutions possible.
2.1.7 … attractive
Attractive design - remarkable user comfort.
Differentiated demands for patient comfort are supported.
Easy to understand, intuitive and safe use and handling.
2.2 Sample ward
The following page shows a sample ward.
2.2.1 Legend
Room lamp Cancel switch//WC
ComTerminal Patient handset
Pull cord call switch ComStationBUS-C
Pneumatic call switch
Flurdisplay
Call switch Power supply unit24V=
4 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
2. Performance features
Fig. 1: Sample ward
24V=
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 5
2. Performance features
6 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
3.1 Presence message
The staff presence message is a substantial prerequisite for the correct and smooth operation of the system. Staff presence switches are fitted at the entrance area of all rooms where medical staff may be. As an option, sensors for automatic reporting of staff presence may be installed.
When entering the room the staff presence switch is activated, and it is deactivated when leaving the room.
3.1.1 Activated staff presence
signals the current where-about of staff.
acknowledges a fresh call in the room.
prepares the room to receive forwarded calls.
prepares the room for raising emergency calls. i.e. rooms with active staff pres-ence switches enjoy higher priority in signalling.
prepares the room for raising a cardiac alarm. Pressing the blue alarm button only raises a cardiac alarm, if staff presence is activated.
deletes the privacy status in the patient room.
Answered or acknowledged calls are cancelled by deactivating the presence switch (Exceptions: WC call, WC Emergency call).
3.1.2 Presence 1 and 2
Flamenco nurse call systems provide presence buttons for two staff groups:
Presence 1 (green button): Nursing staff 1
Presence 2 (yellow button): Nursing staff 2 or doctor
3.1.3 Presence buttons
Large-surface presence buttons are provided in the following devices:
ComTerminal Flamenco (77 0510 00)
RoomTerminal Flamenco (77 0520 00)
Staff presence switch (77 0212 00…)
Staff presence combination with call tone (77 0219 00…)
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 7
3. Functions
Fig. 2: Devices with presence buttons
3.1.4 Indication of presence states
Integrated reminder lights come on when staff presence is active.
Coloured lights in the room lamp indicate activated presence:
Presence 1: green
Presence 2: yellow
At the displays and consoles the presence of the two different staff groups is sepa-rately indicated.
1 Presence button for staff 1, green
2 Presence button for staff 2, yellow
3 Reminder light for staff presence 1, green
4 Reminder light for staff presence 2, yellow
77 0520 0077 0510 00 77 0212 00 A
77 0219 00 A
12
4 3 2 14
3
4
1
31
23
8 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
3.2 Call types and call categories
A call for help is raised by patients, staff or automatically through sensors. Depending on the call event there are different call types which are subdivided into call catego-ries, i.e. priorities. Allocation of call categories is acc. to DIN VDE 0834:2000, how-ever categories may be changed to suit a specific project.
3.2.1 Disconnection call
All patient devices which connected by plug and socket will raise a disconnection call when the connection is released. The resultant call is signalled as a call type ”call”.
While staff Presence is active, a disconnection call will be indicated at the optical dis-play at the room lamp only. However, this call will not be signalled to a console. Rea-son: With staff presence in the room, there must be a possibility to disconnect or exchange patient devices without raising a call.
Call category
Call type Call event
Calls(low priority)
Call A patient has raised a call, or the plug of a call device was pulled off the socket (Disconnection call).
WC call A patient has raised a call from the WC.
Door call The call button at a door entry speaker was pressed (”Ringing”) as request for entry.
Emergency calls
(mediumpriority)
Emergency call 1
Staff 1 (Nursing staff) has raised a call, i.e. a call was raised while Presence 1 was active.
Emergency call 2
Staff 2 (acc. to project understanding: Doctor or Staff 2) has raised a call, i.e. a call was raised while Presence 2 was active.
WC emer-gency call
Staff has raised a call from the WC, i.e. with the Presence activated, a call was raised from the WC.
Telephone call
Automatically raised call when a telephone is active in the staff duty room.
Diagnostic call
A medical monitoring device has raised a call. This may be a device which automatically raises a call when upper or lower monitored values are exceeded, e.g. an Infusomat.
Alarms(high priority)
Cardiac alarm
Staff has pressed a special alarm button to call for assistance, e.g. a re-animation team.
Tab. 1: Call categories and call types
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 9
3. Functions
3.2.2 Call escalation
Call escalation defines which call is displayed at which device and at what time. This ensures that every call is forwarded to the responsible location. The process for call escalation can be configured (Software SystemOrganizer).
Fig. 3: Call escalation (Example)
Patient presses the call button.
Nurse station not occupied.
Call forwarding to all rooms with staff.
Forwarding to another ward.
Forwarding via DECT.
10 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
3.3 Signalling
3.3.1 Signalling in a room
Location light
Call buttons have location lights, i.e. a visual assistance for finding the call button in the dark.
Reassurance light
Reassurance lights at the call device indicate that a call was raised from this button and to provide a reassurance for the patient. The reassurance light will stay on also after activating the staff presence in the room. This way, staff can quickly recognise the call location in the room.
Reminder light
Presence buttons and cancel buttons have reminder lights to show that the particular button.
3.3.2 Room lamps
77 0171 00 77 0170 00 Light section indicates:
Red Call category (call, emer-gency call, alarm)
Green Presence 1
Yellow Presence 2
77 0171 10 77 0170 10 Light section indicates:
Red Call category (call, emer-gency call, alarm)
Green Presence 1
Yellow Presence 2
White WC call, WC emergency call
77 0170 01 Light section indicates:
Blue Cardiac alarm
White WC call, WC emergency call
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 11
3. Functions
Room lamp 77 0170 01 is suitable as amendment to the room lamps 77 0170 00 and 77 0171 00 to indicate calls from the WC and cardiac alarms particularly.
3.3.3 Room lamp universal without RAN connection
The following room lamp is not connected to the room bus RAN. It is for universal use. In the Flamenco system it is used together with ComStationPC or ComStation-BUS-C.
3.3.4 Group lamps and direction lamps
Group lamps in the corridor indicate the calls from another ward when the other ward is coupled with this ward (ward coupling).
Direction lamps in the corridor show arrows to indicate the call location. These lamps are installed at junctions or where orientation could be difficult.
The allocation of rooms to group or direction lamps can be freely configured. The type of signalling can also be configured. Configuration is realised using the Software SystemOrganizer. The following summary describes standard settings for signalling.
Event Colour Fresh call Answered call
Call category: call Red Flashing On
WC call Red + White 1) Flashing On
Emergency call Red Rapid flashing On
WC emergency call Red + White 1) Rapid flashing On
Cardiac alarm Red + Blue 2) Flickering On
Presence1 Green
Presence 2 Yellow
1) only with room lamps 77 0170 01, 77 0171 10, 77 0170 10.2) only with room lamp 77 0170 01.
Tab. 2: Signalling at room lamps
Note! When more than one call are active, the highest category call is indicated. Fresh calls within a call category are indicated before answered calls.
Room lamp universal 77 0182 10
Light section indicates:
Green Presence, ComStation is in use
12 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
Call categories
The call category is indicated in the red light section of the group lamp and the direc-tion lamp:
Call category Call: Steady light.
Call category Emergency call: Slow flashing (1 sec. / 1 sec.).
Call category Alarm: Rapid flashing (0,3 sec. / 0,3 sec.).
Collective display
Red light section: When more than one call is active, the call category of the highest priority call is indicated: Alarm > Emergency call > Call.
3.3.5 Corridor display Alpha 16
At the corridor display Alpha 16 (single-sided version: 77 0150 00, double-sided ver-sion: 77 0160 00) call type and room number of the call location are indicated with alphanumerics.
The display can show 16 characters. Longer messages are shown as ticker.
Additionally the calls are signalled acoustically. Different call tones are allocated to each of the three call categories. Using the software SystemOrganizer the call tone volume can be set separately for every ward to „soft“, „medium“ or „loud“.
Direction lamp 77 0111 02 Light section indicates:
Red Call category (call, emer-gency call, alarm)
Green Presence
Group lamp 77 0112 02 Light section indicates:
Red Call category (call, emer-gency call, alarm) of group1
Green Presence of group 1
Red Call category (call, emer-gency call, alarm) of group 2
Green Presence of group 2
Light section Steady light Slow flashing Rapid flashing
Red Call Emergency call Alarm
Green Presence - -
Tab. 3: Signalling at group lamps and direction lamps
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 13
3. Functions
When several calls are active, the highest priority call is indicated. As an option it can be configured that all calls are indicated again and again in a rolling manner (Soft-ware SystemOrganizer).
Clock time is the standby indication.
14 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
3.4 Consoles
Consoles are primarily designed for the displaying and handling of calls. For this, Fla-menco provides a line of consoles to cater for diverse demands. The programme covers the following categories.
3.4.1 Ward console: ComStation
ComStationBUS-C
Category Application
Ward console Ward consoles are used for handling calls in a ward. Ward consoles in the Flamenco nurse call system are called ComStation. These ComStations are available in several versions.
Mobile console Mobile consoles are wireless telephones used for call handling. They can be used in support of the other con-soles. As staff can carry a wireless along, calls can be forwarded directly to the responsible nursing staff.
Central console A central console is a console where normally calls from all wards or from several houses are handled. The central consoles for the Flamenco nurse call system are referred to as ManagementCenter.
Call forwarding point Call forwarding points are devices used to answer for-warded calls in the rooms. With Flamenco systems these are ComTerminals.
Tab. 4: Consoles
The ComStationBUS-C is designed or answering and handling calls and to support nursing service. The ComStationBUS-C is equipped with microphone, loudspeaker and handset for speech communica-tion. The ComStationBUS-C is operated using select and navigation keys, supported by a colour display. System messages and additional information can be displayed as well.
ComStationBUS-C
(77 0605 50)
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 15
3. Functions
ComStationPC
ComStationCT Flamenco
3.4.2 Mobile console: Wireless telephone
The ComStationPC is a PC workstation with speech unit. Calls and presence states are presented in a ward planview. This ensures the quick identification of locations.
Calls and Emergency calls are shown in Red, Alarms in Blue, Presence 1 in Green, and Presence 2 in Yellow. The three call categories are enhanced through flashing indications, i.e. Calls - slow flashing; Emergency calls - quick flashing; Alarms - rapid flashing. In addition, call categories are also presented with special acoustic signals. As soon as a call is answered, the call type is indicated.
ComStationPC
(77 0602 00)
A ComStationCT Flamenco is the simplest type of a ward console. Calls are signalled via an acoustic tone generator, and there are different signals for each of the three call categories. The display will show call type and call location. When two or more calls are present, the highest priority call is indi-cated.
ComStationCT Flamenco(77 0606 00)
The display will show call type and call location. Other features of the mobile console depend on the type of wireless telephone used or on the type of PBX, respectively.
The mobile consoles are not part of the Flamenco nurse call system. They are part of a PBX which is coupled to the Flamenco system via an interface in the OSY-ControlCenter. OSY-CC VoIP-SIP Inter-face offers the coupling of a PBX for mobile speech communication.
16 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
3.4.3 Central console: ManagementCenter
3.4.4 Call forwarding point: ComTerminal Flamenco
The ManagementCenterPC is a PC workstation with speech unit. The ManagementCenterPC Push but-tons features additional push buttons.
Calls and presence states are indicated at the Man-agementCenterPC in the same manner as at the ComStationPC - with the addition that several wards are presented.
The ManagementCenterPC Push buttons features a push button for each room to quickly establish a speech communication to the respective room. Each push button has three LEDs for optical signal-ling: Red for Calls, Green for Presence 1 and Yellow for Presence 2. The flashing rhythm of the Red LED indicates the call category: Calls - slow flashing; Emergency calls - quick flashing; Alarms - rapid flashing.
ManagementCenterPC
(77 0610 00)
ManagementCenterPC Push buttons(77 0620 00)
When presence is active the display in the ComTer-minal Flamenco shows call type and location of the forwarded call. In addition, there are the acoustic signals, i.e. different signals for each call category
The call tone volume can be configured using the SystemOrganizer software.
ComTerminal Flamenco(77 0510 00)
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 17
3. Functions
3.5 Call handling
3.5.1 Raising a call
Calls are raised activating a specially marked call button. Call buttons at Tunstall devices are Red, showing a nurse logo. Exception: Cardiac Alarm (Blue button).
Call buttons are integrated in ComTerminal Fla-menco, patient handset and pear push switches. But they are also available as call switches.
Optional devices include pull cord and pneumatic switch.
Patient handset(74 0747 00)
Product Call trigger Person Call type
Patient handset Red call button Patient Call with bed identification
Pear push switch Red call button Patient Call with bed identification
ComTerminalRoomTerminal Call button
Red call button Staff Emergency call 1)+ Call
ComTerminal RoomTerminal Alarm button
Blue alarm button 1) Staff Cardiac alarm 1)
Call switch in the room
Red call button, pull cord, pneumatic activa-tion
Patient, Staff
CallEmergency call 1)
Alarm switch in the room
Blue alarm button 1) Staff Cardiac alarm 1)
Call switch/WC Red WC call button, pull cord, pneumatic activa-tion
Patient, Staff
WC callWC emergency call 1)
Diagnostic con-nection cable
Contact electro-medical device
automati-cally
Emergency call
1) Prerequisite: Presence is activated
Tab. 5: Call devices
18 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
3.5.2 Accepting a call
A raised call is first acknowledged or answered.
Call acknowledging
Accepting a call without establishing a speech communication is called 'acknowledg-ing'. This is effected at the call location by activating the presence status. Or this is effected in another room to which the call has been forwarded. Using the following devices forwarded calls can be remotely acknowledged: RoomTerminal Flamenco, ComStationT Flamenco.
Call answering
Accepting a call by way of a speech connection is called 'answering a call'. Devices for answering a call are designated as consoles: Ward console (ComStation), Cen-tral console (ManagementCenter), Mobile console (Wireless telephone), Call for-warding point (ComTerminal).
3.5.3 Speech
After answering a call there is a speech communication between the console and the call location.
3.5.4 Call cancelling
When the person seeking assistance has been satisfactorily handled, the call must be cancelled.
Call cancelling at the call location
Calls can be cancelled at the call location. Prerequisite: Staff must have acknowl-edged or answered the call first.
Call cancelling at the call location is automatically effected by de-activating the pres-ence button. WC calls and WC Emergency calls must normally be cancelled by ac-tivating a special WC cancel button.
Remote call cancelling from the console
Specific call types (Standard: Call type: calls) can be remotely cancelled from the console after a speech communication was established.
Call type Cancelling method
Call At the call location automatically by de-activating the presence or remote cancelling from console after a speech was established to the call location.
WC call Pressing the grey WC cancel button.
Door call A door call is cancelled as a remote function from the console, after a speech connection was established to the call location.
Tab. 6: Cancelling of different call types
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 19
3. Functions
3.5.5 Call forwarding
Call forwarding is the forwarding of calls to rooms where staff have activated their presence. At the ComTerminal, forwarded calls are signalled both in the display and by acoustic signal with call type and call location shown in the display.
The cancel switch/WC (77 0213 00...), the call switch/WC with cancel switch (77 0217 00...) and the staff presence combination with call tone (77 0219 00...) is-sue an acoustic signal. There is a different call tone for each call category.
Forwarded calls can be answered via the ComTerminal (call forwarding point). If speech communication to the call location was established, the forwarded call may be cancelled from the ComTerminal remotely.
Telephone call A telephone call is automatically cancelled when no telephone call is present. Manual cancellation is not possible.
WC emergency call Pressing the grey WC cancel button.
Emergency call 1 De-activating the presence at the call location.
Emergency call 2 De-activating the presence at the call location.
Diagnostic call Deleting the call at the initiating device plus de-activat-ing the presence.
Cardiac alarm De-activating the presence at the call location.
Call type Cancelling method
Tab. 6: Cancelling of different call types
20 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
3.6 Speech communication
3.6.1 Speech devices at consoles
ComStationBUS-C, ComStationPC und ManagementCenterPC
Speaking in the hands-free mode or - for more discretion - by using the hand-held receiver. If background noise is distractive, voice communication can be changed to half-duplex speech with manual control of the speech direction.
ComStationCT Flamenco
Free speaking via microphone and loudspeaker.
Wireless telephones
These units are normal telephones, and as such, communication is the same as with any conventional telephone connection.
3.6.2 Speech devices in a room
Speaking per room
Free speaking via microphone and loudspeaker in the ComTerminals.
Speaking per bed
Each bed has its own speech device (Patient handset). Speech communication ei-ther free or more discretely with reduced volume.
Non-system patient device
Aside from using Tunstall's Patient handset, bedside speech communication can also be effected with other make patient devices, e.g. with a patient telephone. In this case, communication features are determined by this particular device.
3.6.3 Privacy function
The system features an automatically controlled privacy function. This ensures un-authorised eavesdropping of persons.
To cater for specific situations, the privacy function can be disabled. This can be car-ried out automatically or manually. The status of the privacy function depends on:
Situation (call, presence status)
Setting of privacy button at the ComTerminal or at separate switch with privacy button
Room type „children's room“ (set at ComTerminal and in SystemOrganizer))
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 21
3. Functions
Privacy function principle
3.6.4 Announcements
Announcements can be initiated from ward consoles ComStation and central con-soles ManagementCenter.
Announcements are transmitted to ComTerminals, patients handsets, corridor dis-plays, and loudspeakers with announcement interface (e.g. in corridors or outside ar-eas.)
An announcement interrupts radio / TV programmes at the patient handset. An-nouncements can be preceded by a preparatory tone or by a prepared text (to be configured).
Call is active? yes Listening in possible
no
Listening in not possible
yes Privacy button activated?
no
Presence status activated? yes Listening in possible
no
Listening in not possible
no Setting “Children's room”? yes Listening in possible
Type of announcement Locations to transmit the announcement to
Ward announcement All rooms of a ward.
Staff announcement All rooms where staff is present. Optional Pres-ence 1 or Presence 2 or Presence 1+2.
Area announcement (free selectable area) *)
Selected rooms or wards.
Area announcement (defined area) *)
Defined area selected from a list. The list is con-figured in the SystemOrganizer.
Multiple line *) Several rooms. From rooms where privacy is off an answer can be received.
Tab. 7: Announcement types
22 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
3. Functions
Defined rooms can be excluded from the announcement, e.g. rooms with a ward con-sole ComStation, operating theatres.
Automatic announcements can be activated. In this case, prepared text messages are transmitted to the configured areas. The activation is effected from ward con-soles ComStationPC or central consoles ManagementCenter.
General announcement *) All rooms which the ManagementCenter console is in charge of.
*) not available at ComStationBUS-C.
Type of announcement Locations to transmit the announcement to
Tab. 7: Announcement types
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 23
3. Functions
3.7 Rooms without speech communication
It is possible to integrate rooms without speech communication into the nurse call system. Instead of ComTerminal Flamenco these rooms are equipped with RoomTerminal Flamenco or ControlTerminal Flamenco. The room periphery which is connected to the ComTerminal Flamenco can be connected to the RoomTerminal or ControlTerminal as well.
3.7.1 RoomTerminal Flamenco
3.7.2 ControlTerminal Flamenco
The ControlTerminal Flamenco (77 0550 00) has no keys. But therefore it includes a room lamp with 4 sections. As an option it is available with an integrated label field for room designation: ControlTerminal with doorplate (77 0551 00).
The signalling of the ControlTerminals equals to the room lamps 77 0170 10 and 77 0171 10, table 2 on page 12.
The RoomTerminal Flamenco is a complete replacement for the ComTerminal Flamenco but without speech communication.
When staff presence is active forwarded calls are displayed in the RoomTerminal's display. Call type and call location are displayed. Additionally the for-warded calls are acoustically signalled via a tone. The call tone differs for the three call categories.
The call tone volume can be configured in the Sys-temOrganizer software.
RoomTerminal Flamenco(77 0520 00)
77 0551 00 77 0550 00 Light section indicates:
Red Call category (call, emer-gency call, alarm)
Green Presence 1
Yellow Presence 2
White WC call, WC emergency call
24 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
4. Interfaces - OpenConcept
Flamenco nurse call systems feature several interfaces for connections in rooms, in a group and at the central control. Flamenco is designed as open-architecture for a number of other technical systems, i.e. Flamenco expands its functional spectrum by using other systems and it provides its own nurse call system for other systems. This synergy effect is your profit. You can combine the best and optimised individual solu-tions and products to create a powerful and cost-effective communication concept.
Abb. 4: OpenConcept
OSYlink AS
LAN/W
LAN
VoIP/SIP
ESPA 4.4.4
KIS/IT
Transport systemsBMA/GMS
TV
Entertainment
Licht/Raum
Mobile
Telef
onie
Pers
onal
plan
ung
Not
fallm
anag
emen
t
Pers
onal
schu
tz
Tele
met
rie A
larm
Emer
genc
y m
anag
emen
t
Staf
f pla
nnin
g
Mobile
telep
honyLicht/R
aum
Tele
met
ry a
larm
Sfta
ff pr
otec
tion
TransportsystemeFDS/DSS
HIS/IT
Light/space
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 25
4. Interfaces - OpenConcept
4.1 Interfaces in rooms
4.1.1 Light switching
The patient handset (74 0747 00) has 2 buttons for room and reading light. The pear push switch with call and light switch has a button for switching the light.
4.1.2 Radio / Television
The patient handset (74 0747 00) features an integrated loudspeaker and a socket for earphones for radio and TV sound. When the ear phones are connected, the loud-speaker is disabled. Switching on/off, program selection as well as volume control via the buttons on the patient handset.
Up to 5 permanently installed programs from the entertainment system are available via the connection socket. TV systems with integrated radio broadcast are connected via the RAN interface (77 0840 00). The arrangement caters for a random number of radio programs which are relayed via the tuner in the TV system. Control of the TV system: TV On/Off, program selection Up/Down.
When using the IR TV control module universal (70 0360 00) every standard TV set can be used. Or the TV set is equipped with an appropriate interface (RSIG).
4.1.3 Call devices
In addition to the nurse call devices of the Flamenco product range, additional call devices can be used, e.g. radio transmitters for wireless calling. As such, the con-nector of the 1-channel radio receiver (70 0831 00) can directly be plugged into the connection sockets (70 0171 03, 70 0171 50, 70 0424 00, 70 0424 50, 70 0434 00, 70 0434 50, 70 0448 00, 70 0449 00) from the Flamenco system.
The RAN interface (77 0840 00) supports the connection of other non-Flamenco call devices. Besides the call types Call, Cardiac alarm and WC call the RAN interface supports location light and reassurance light function as well as bed identification.
4.1.4 Patient units
If so desired, patient handsets other than the Tunstall patient handset may be used. Suitable alternatives are, for instance, patient telephones with built-in nurse call but-ton. The RAN interface with speech (77 0880 00) links the call button and the tele-phone speech path to the nurse call system. The selection of devices from third-party manufacturers must be coordinated with Tunstall.
26 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
4. Interfaces - OpenConcept
4.2 Interfaces at group bus
4.2.1 OSYlink-Universal
Inputs and outputs
4 monitored Inputs:- 2x Call- Emergency call- Alarm
1 Input, Collective announcement (to all wards)
1 Input, Collective announcement (to all staff)
1 Input for raising a call, associated an input for cancelling this call.
4 configurable solid state outputs. Factory setting:- 2x Call- Emergency call- Alarm
1 configurable solid state output
1 configurable solid state output with location light feature (functionally associat-ed with the inputs for calls)
2 configurable potential-free outputs (change-over contact, voltage source can be selected by jumper)
The outputs are configured using the SystemOrganizer.
4.2.2 Linking of legacy systems
Flamenco provides the option of connecting wards of legacy systems manufactured by Tunstall GmbH to the Flamenco system in a compatible way. For this, the ward bus of the legacy system is connected to the Flamenco system via an OSYlink AS interface module. Two different interface modules of OSYlink AS are available, de-pending on the legacy system.
The universal interface OSYlink-Universal (77 0803 00) is provided for linking of systems from third-party manufacturers and/or technical equipment with the group bus (OSYnet).
OSYlink-Universal(77 0803 00)
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 27
4. Interfaces - OpenConcept
OSYlink AS-CCS
OSYlink AS-CCS transforms the data and speech signals of legacy CCS systems into compatible signals for the Flamenco system. This way, it is possible to run indi-vidual wards using CCS technology in a Flamenco system environment.
For connecting a half-duplex speech system additionally a speech amplifier with in-dependent power supply unit is required. Normally this was already part of the legacy system.
OSYlink AS-L200
OSYlink AS-L200 transforms the data signals of the room terminals and the universal interfaces L200 of the legacy L200 system into compatible signals for the Flamenco system. This way, it is possible to run individual wards using L200 technology in a Flamenco system environment.
OSYlink AS type Legacy systems which can be linked
OSYlink AS-CCS(77 0870 00)
EccoLine with speech
NewLine C201
NewLine
CCS 2000 G
CCS 1080 G
CCS 1080 W
OSYlink AS-L20077 0872 00)
EccoLine L200
NewLine L200
Tab. 8: Modules for connecting of legacy systems
28 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
4. Interfaces - OpenConcept
4.3 Interface at the central control
The powerful OSY-ControlCenter (77 2000 00) monitors and controls not only nurse calls, it also serves as the turntable for links with external systems.
There are two central LAN interfaces for the data exchange with external systems. Depending on the application the communication is effected directly via the OSY-ControlCenter or via an separate server. For simple connections serial interfaces can be used.
For any details with your specific project, talk to the Tunstall representative. The fol-lowing paragraphs present some sample applications.
4.3.1 Radio paging system, DECT without speech
The nurse call system is prepared for the connection of radio paging systems or DECT telephone systems. The protocol is based on ESPA 4.4.4. This way, incoming calls from the nurse call system can be relayed to staff who carry a radio paging re-ceiver or a wireless phone.
The factory settings for the ESPA interface are: 1200 baud, 7 bits, even parity, 2 stop-bits. Format: <Event Identifier><Space><Ward Name><Space><Room Name><Space>.
4.3.2 Telephony (DECT, VoIP, WLAN, GSM)
A hospital's telephone infrastructure may also be used for speech communication with the nurse call system. Whether DECT, VoIP, WLAN, or GSM, all variants can be linked with the nurse call system. The telephone user will not note any difference.
When an external device should fail, e.g. due to a failure in the telephone system, Flamenco ensures that an active call is indicated at other display equipment within the nurse call system.
4.3.3 Hospital information system (HIS)
To support the work of nursing staff, patient data may be presented during call han-dling. The data are managed in the software PrimusGlobal+. Data can be exchanged between the software PrimusGlobal+ and the hospital information system. This way, there is no need for dual data entry.
The system driver HL7 links the hospital information system and the software family PrimusGlobal+. Defined data fields from the HL2 dataset are used, and they are available for further indication at the ManagementCenter. Selection of the desired in-formation is realised in close cooperation with the respective customer. Various transfer protocols and transfer methods can be realised.
Linking of the hospital information system is effected at the OSY-ControlCenter. For this realisation, a ManagementCenter with PrimusGlobal+ Module “Connect” and the PrimusGlobal+ system driver HL7 are required.
4.3.4 Fire detection system
Defined information from the fire detection system can be taken over by the Flamen-co system where they are used for other displays and for further processing. The
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 29
4. Interfaces - OpenConcept
type and amount of information as well as priority rating of such information will be defined in close cooperation with the customer
4.3.5 Facility management system
Defined information and events from the nurse call system Flamenco are transferred via interfaces to the facility management system where they are available for display-ing and for further processing. The type and amount of the events to be transferred will be defined in close cooperation with the customer.
Connection to the facility management system is realised at the OSY-ControlCenter. For this realisation, a ManagementCenter is required with PrimusGlobal+ Module “Connect” and the PrimusGlobal+ system driver FMS.
4.3.6 Use of nurse call system infrastructure by other systems
Optical and acoustic signal devices of the Flamenco nurse call system can also be made available for external systems. As such, corridor displays may present addi-tional information, e.g. Alarms from a fire detection system, information from the caf-eteria, notes on the use of mobile phones, etc. Other external systems may also be integrated to activate room and group lamps and/or acoustic signal generators of the nurse call system.
Exploit theses additional features for the nurse call system and stop additional cost from dual installations of displays, loudspeakers and other signalling devices. Use the idle time periods of the Flamenco displays and indicators to disseminate other information, messages, clock time, routing information, visitor information, etc.
30 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
5. Organisational modes
The Flamenco nurse call system can be adapted to a hospital's care organisation. Independent from the installation, the system can support various modes of a care organisation. Organisational changes can be realised without the need for additional
installation or for structural changes.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 31
5. Organisational modes
5.1 Ward operating mode
The ward operating mode is the traditional way of method for the handling of nurse calls. All calls within a ward will reach the responsible staff either directly at a ward console ComStation at the nurse station or at their respective present location (call forwarding).
Fig. 5: Ward operating mode
The ward operating mode is the ideal method for call handling when function care is the care solution that is realised for the ward. In functional nursing all care jobs are allocated and handled by all of the ward staff. Each nurse will handle tasks (func-tions) for all patients in the ward.
1 – 6 Wards 1 – 6
ComStation
ComStation
ComStation
ComStation
ComStation
ComStation
1 2
3 4
5 6
32 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
5. Organisational modes
5.2 Ward coupling
During periods of low activity, two or more wards which are operated in ward mode can be organisationally coupled. In Flamenco nurse call systems, this is realised with the 'ward coupling' function. All calls and presence states of the coupled wards are displayed at the consoles of all coupled wards or forwarded to rooms with active presence states, respectively.
The coupling of specific wards is pre-defined by the technical staff using the software SystemOrganizer. Nursing staff will activate the applicable ward coupling at the ComStation as required.
Fig. 6: Ward coupling
1 – 6 Wards 1 – 6
1 + 2 Ward 1 is coupled with ward 2
3 + 4 Ward 3 is coupled with ward 4
5 + 6 Ward 5 is coupled with ward 6
ComStation
ComStation
ComStation
ComStation
ComStation
ComStation
1 + 2
3 + 4
5 + 6
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 33
5. Organisational modes
5.3 Central call handling
In the central call handling mode, all calls of all wards are directed exclusively to a superior central console, a ManagementCenter, answered from this central console and from here, all further measures are initiated. The central console Management-Center is suitable to act as the sole console position in a house. The central call han-dling mode may also be realised as a temporary measure, only, e.g. during night time, or in a mode where individual wards operate in a decentralised mode from time to time.
Aside from patient rooms and function rooms, all rooms where staff or patients may dwell must be incorporated into the system. To fully exploit the possibilities of the ManagementCenter all additional functions should also be integrated in the system (administration, X-ray, pharmacy, etc.).
Fig. 7: Central call handling
The central call handling mode is perfectly suitable when several hospitals are cou-pled. In this case, one ManagementCenter is responsible for all coupled houses.
ManagementCenter
34 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
5. Organisational modes
5.4 Zone nursing
In the case of 'zone nursing' the ward is divided into structural sections commensu-rate with the building architecture. Nursing staff is organised in teams, and each team is responsible for a certain zone. Suitable consoles for zone nursing are ward con-soles ComStation or mobile consoles, i.e. wireless telephones. Call forwarding is also prepared for within the zone.
Fig. 8: Zone nursing
5.4.1 Shifts
Depending on the day of the week or on the clock time, it may be necessary to change zone allocations. For instance, two zones of daytime operations may be joined to create a single zone for the night time. With Flamenco nurse call systems this change to the nursing situation is be realised by way of shift allocation.
The software SystemOrganizer is the tool to set up work shifts and to compose the zones for the respective shift. At the ComStation, nursing staff can change the nurse call system from one shift mode to another shift mode, i.e. day shift volume and night shift volume.
Team 1 Team 2
Zone 1 Zone 2
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 35
5. Organisational modes
5.5 Room nursing
In the case of room nursing, one team of nursing staff is responsible for all patients in one or more rooms. As for the nurse call system, this essentially constitutes zone nursing, where the rooms are not necessarily next to each other. The configuration procedure for this nursing mode is virtually the same as for area nursing.
Fig. 9: Room nursing
Team 1 Team 2
Zone 2 Zone 1 Zone 1 Zone 2 Zone 2
Zone 1 Zone 2 Zone 1 Zone 1 Zone 1
36 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
6. Configuration / SystemOrganizer
Fig. 10: SystemOrganizer (77 0750 00)
The SystemOrganizer software is the planning and configuration tool for the Flamen-co system. It provides the user interface to the system control unit OSY-Control-Center and enables the complete parameter setting for the nurse call system.
The handling and the subdivision follows Flamenco's basic principle. The physical parameters are strictly separated from the organisational assignments.
The access is password protected by 5 different user levels. Herewith is ensured, that each user group (planning office, care management...) can only make the set-tings, which are important for him/her.
Right from the planning stage the SystemOrganizer is used to enter the project struc-tures of buildings, wards and rooms. All parameters can be modified every time to adapt to the respective needs.
By using the data from the beginning of the planning over the whole life cycle of the system it will never be necessary to enter data twice. All data can be copied, saved and readout from an OSY-ControlCenter. Herewith it is ensured, that every time the valid data are used
6.1 Requirements
Microsoft Windows 7, Windows XP, or Windows 2000
10/100 Mbit LAN access
Software training “SystemOrganizer”
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 37
6. Configuration / SystemOrganizer
6.2 System planning
Construction of the basic structure of buildings, wards, rooms
Plan view presentation
Screen shot directly from the screen
Import of existing graphics
Various pre-set room types
Free allocation of room numbers and designations
Printable survey of buildings, wards, rooms
6.3 Configuration
Country-specific settings
Setting date and time
Assignment of physical addresses for rooms and peripherals
Designations and room numbers for rooms, wards, buildings, etc.
Setting call types and system messages
Signalling options e.g. tone and flash-signal sequences
Parameters for call handling e.g. call types, call categories
Defining announcement areas
Organisational assignment of rooms (locations) to wards, shifts, etc.
Defining ward couplings
Parameter setting for escalation procedures for call handling
Administration of interfaces to external systems
Administration of cordless telephony devices (DECT/radio paging system/WLAN)
Setting all system parameters including the administration of integrated networks and IP addresses
38 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
7. The technology
Fig. 11: System overview
PSA: Radio paging systemBMA: Fire detection systemKIS: Hospital information system
OSYnet-SafetyController
OSY-ControlCenter
PSA / DECT
BMA
KIS
...
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 39
7. The technology
7.1 System structure
The nurse call system uses a bus system with a group bus (OSYnet) and an intelli-gent room bus (RAN). The group bus OSYnet combines individual rooms and possi-ble interfaces in the ward in a network. The room bus serves as the network for the various devices in a room.
System control is centrally effected in the OSY-ControlCenter. The OSY-Control-Center handles both data flow management and speech communication.
For larger systems several OSY-ControlCenters may be coupled.
If the OSY-ControlCenter should fail, decentralised OSYnet-SafetyControllers will handle the light call functions. In the wards, they are connected to the group bus OSYnet.
Electric power supply for the system is realised via decentrally installed power supply units. The number of such units and their locations depend on the total electric power that is needed. Power to the OSY-ControlCenter is also provided via an external power supply unit.
Fig. 12: System structure
– : Group 1 – 4 OSYnet: Group bus
RAN: Room bus
OSY-ControlCenter
...
...
...
...
40 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
7. The technology
7.2 Control unit OSY-ControlCenter
The complete system control is centrally effected in the OSY-ControlCenter. The system control com-prises data transmission including system functions and a separate speech system.
The OSY-ControlCenter serves as the central sys-tem interface for input and output of data, for speech connections and system messages, and also for remote access and system updating.OSY-ControlCenter
(77 2000 00)
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 41
7. The technology
7.3 Speech communication
Speech communication and data transmission are physically and logically separated from each other. The speech line of the system connects the system's own speech units: ComTerminal Flamenco, Patient handset, ComStationBUS-C, ComStationPC, ComStationCT Flamenco, ManagementCenterPC, ManagementCenterPC Push but-tons.
7.3.1 Non-system speech paths
Aside from speech communication within the nurse call system, speech communica-tion is also possible with other speech units: patient telephones, wireless telephones (DECT or GSM mobile) etc. The interfaces to the telecommunication systems are provided at the OSY-ControlCenter.
The various devices can be used along with the Tunstall patient devices or consoles with nearly the same quality or functions. Their use can be in an exclusive mode or in a mixed mode. But the planning and design of such solutions require detailed knowledge of the technology, the operational spectrum and of down-line functional and organisational sequences.
Fig. 13: Non-system speech paths
Wireless telephone Patient's telephone
OSY-ControlCenter
...
...
...
DECT
42 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
7. The technology
7.4 Cables
7.4.1 Types of cable
The installation can be realised using a data cable, e.g. CAT7 (22 AWG), or commer-cially available installation cables for communication systems e.g. IY(ST)Y4x2x0.8.
Electric power for all components is provided via a separate net, also with commer-cially available cables, e.g. 2x2,5 mm².
For detailed information on the types of cables to be used, refer to page 71. Maxi-mum permissible cable lengths in an OSYnet
Fig. 14: Maximum permissible cable lengths in an OSYnet
= Bus termination at last bus user (= 120 Ohms resistor)
Group 1, Ward 1
Group 2, Ward 2
Group 5, Ward 7
Group 3, Ward 4
Group 3, Ward 3
Group 4, Ward 5
Group 4, Ward 6
max. 700 m
ba + b = max. 700 m
c + d + e = max. 700 m
a
c
e
d
OSYnet-Gateway
OSYnet-Y-RepeaterOpto
max. 700 m max. 700 m
OS
Y-C
ontro
lCen
ter
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 43
7. The technology
7.5 Wards and groups
Fig. 15: Distribution of wards to groups
Wards are the organisational entities in hospitals. As such, a ward is a comprehen-sive entity also for normal operations in Flamenco nurse call systems. However, the physical structure in Flamenco nurse call systems is independent of this organisa-tion.
During the development of Flamenco the organisational structure was totally sepa-rated from the technical structure. Rather than the ward, it is the 'physical' group which - technically speaking - is the entity. Each group is managed via a control unit (which is a module in the central control unit OSY-ControlCenter). A group may com-prise several wards. As a matter of fact, wards may be distributed among or allocated to various groups.
This group-related arrangement provides for many advantages. The number of con-trol units can be substantially reduced. The number of required control units or groups is not determined by the number of wards but rather by the building structure and by the desired fail-safe criteria.
The physical structure's independence from the organisational structure provides for another substantial advantage: Planning personnel does not have to consider any later organisational structure while planning the physical installation for the system phase for the physical installation of cabling and devices. At any later date, the sys-tem can be altered and adjusted to a changed organisation without being limited by the system's physical structure.
Ward = Organisational entity
Group = Physical entity
Organisation of hospital Flamenco Technology
Ward 1 Ward 2 Group 1
Ward 5 Ward 6 Group 3
Ward 3 Ward 4 Group 2
44 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
8. System safety
8.1 Partial system failure
Flamenco nurse call system feature a hierarchic structure. In case of a failure of in-dividual group users, the remaining users will continue to operate as designed. Room functions will remain functional also when the associated group bus should fail. A raised call is still indicated at the room lamp. The initiating call device can easily be identified by the illuminated reassurance light.
All call initiating elements and their transmitting routes are monitored. Failures or de-ficiencies in the transmission of calls are indicated for the nursing staff with no delay, using the displays and indications still available.
8.2 Failure of coupled systems
In most applications, the Flamenco nurse call system is coupled with other systems. Nevertheless, the nurse call system will sustain as a self-contained system. In other words, also in case of failures at telecommunication systems, data networks, TV sys-tems or at other interfaces, the functions of the Flamenco nurse call system will re-main operational.
8.3 Fail safe acc. to DIN VDE 0834:2000
The OSYnet Safety Controller is directly connected to the group bus. Each group must have its own OSYnet-SafetyController.
8.4 Failure of the electric power supply
In case of a mains failure, current calls and status information are stored and will not be lost. Configuration data are redundantly stored in the system.
In normal installations, the call system is connected to an auxiliary power supply sys-tem. In case of a failure in the mains supply net, this auxiliary device will sustain the necessary electric power.
The OSYnet-SafetyController (77 2100 00) com-plies with the fail safe requirement acc. to DIN VDE 0834:2000. Where this high safety standard is not required, there is no definite demand for the use of the OSYnet-SafetyController.
In case of a failure of the central system control, the OSYnet-SafetyController automatically sustains the light call functions of the nurse call system, but not including speech communication. The controller supports call forwarding. Signalling at the room lamp is ensured via the ComTerminal.
OSYnet-SafetyController(77 2100 00)
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 45
8. System safety
Where a building is not fitted with an auxiliary power supply system, the auxiliary sup-ply for the Flamenco nurse call system must be ensured by other means. For this, there is e.g. a special power supply unit (77 3400 00). Its integrated batteries ensure the uninterrupted supply for at least 15 minutes. Separate uninterruptible power sup-ply systems (UPS) are required for units (e.g. PCs) which are not connected to the 24 V power supply net. These UPS must be provided by the customer.
8.5 Differentiated indication of fault location
The affected locations of technical faults are immediately displayed at the consoles so that nursing staff is informed without delay. In addition, the OSYnet-SafetyCon-troller has a potential free output (change-over contact) for the signalling of faults, i.e. for connection to optical or acoustic fault indicators. Further fault information can be obtained via remote access.
Using the integrated test function in the ComTerminal a defective component in the room will quickly be located.
46 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
The following pages show a selection of frequently used room types with examples on equipment and devices.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 47
9. Room types
9.1 Patient room
9.1.1 Patient room with speech
70 0434 00
70 0424 00
77 0510 00
77 0170 00
74 0747 00
74 0747 00
77 0211 01 A
77 0213 00 A
OSYnet + Ip OSYnet + Ip
77 0215 01 A
In
Is
Is
In
In
Ie
Ie
IePA system (100 V) on-siteSystème de diffusion musique fourni par le client
ELA-Anlage bauseits
48 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
For required back boxes and connectors refer to page 68. For cable legend see page 71.
Per room
ComTerminal Flamenco 77 0510 00
Room lamp for display of all call types and presence states:e.g. Room lamp, 3 sections
optional with individual indication for WC call / WC emergency call:e.g. Room lamp, 4 sections
77 0170 00
77 0170 10
Per bed
Connection socket combi orConnection socket combi, bedhead unit
70 0424 0070 0434 00
Patient handset in corner seating unit (optional) 74 0747 00
In WC room
If additional display for WC call / WC emergency call is desired, e.g. as direction lamp in front of the WC:Room lamp cardiac alarm, WC 77 0170 01
WC cancel button to cancel WC calls / WC emergency callse.g. Cancel switch/WC 77 0213 00 A
A nurse call device must be within reach from washbasin, WC, shower, bathtub; selection:Call switch/WCPull cord call switch/WCPneumatic call switch/WC
77 0211 01 A77 0215 01 A77 0216 01 A
In corner seating unit (optional)
Call device, e.g. Call switch 77 0211 00 A
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 49
9. Room types
9.1.2 Patient room without speech, with ControlTerminal
70 0171 50
70 0171 03
77 0550 00
70 0710 00
77 0211 01 A
77 0213 00 A
OSYnet + Ip OSYnet + Ip
77 0215 01 A
In
In
In
In
In
70 0710 00
77 0219 00 A
50 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
For required back boxes and connectors refer to page 68. For cable legend see page 71.
Per room
Optional:ControlTerminal FlamencoControlTerminal Flamenco with doorplate
77 0550 0077 0551 00
ControlTerminal installation kit 77 0960 00
ControlTerminal ConfigSet(only one is required per nurse call system)
77 0920 00
Staff presence combination with call tone 77 0219 00 A
Per bed
Connection socket with call switch orConnection socket with call switch, bedhead unit
70 0171 0370 0171 50
Optional:Pear push switch incl. call and light switch, 2 m connection cablePear push switch incl. call and light switch, 4 m connection cablePear push switch incl. 2 call switches, 2 m connection cablePear push switch incl. 2 call switches, 4 m connection cable
70 0710 00
70 0710 01
70 0711 0070 0711 01
In WC room
WC cancel button to cancel WC calls / WC emergency callse.g. Cancel switch/WC
77 0213 00 A
A nurse call device must be within reach from washbasin, WC, shower, bathtub; selection:Call switch/WCPull cord call switch/WCPneumatic call switch/WC
77 0211 01 A77 0215 01 A77 0216 01 A
In corner seating unit (optional)
Call switch 77 0211 00 A
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 51
9. Room types
9.1.3 Patient room without speech, with RoomTerminal
70 0171 50
70 0171 03
77 0520 00
77 0170 00
70 0710 00
77 0211 01 A
77 0213 00 A
OSYnet + Ip OSYnet + Ip
77 0215 01 A
In
In
In
In
In
70 0710 00
52 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
For required back boxes and connectors refer to page 68. For cable legend see page 71.
Per room
RoomTerminal Flamenco 77 0520 00
Room lamp for display of all call types and presence states:e.g. Room lamp, 3 sections
optional with individual indication for WC call / WC emergency call:e.g. Room lamp, 4 sections
77 0170 00
77 0170 10
Per bed
Connection socket with call switch orConnection socket with call switch, bedhead unit
70 0171 0370 0171 50
Optional:Pear push switch incl. call and light switch, 2 m connection cablePear push switch incl. call and light switch, 4 m connection cablePear push switch incl. 2 call switches, 2 m connection cablePear push switch incl. 2 call switches, 4 m connection cable
70 0710 00
70 0710 01
70 0711 0070 0711 01
In WC room
If additional display for WC call / WC emergency call is desired, e.g. as direction lamp in front of the WC:Room lamp cardiac alarm, WC 77 0170 01
WC cancel button to cancel WC calls / WC emergency callse.g. Cancel switch/WC 77 0213 00 A
A nurse call device must be within reach from washbasin, WC, shower, bathtub; selection:Call switch/WCPull cord call switch/WCPneumatic call switch/WC
77 0211 01 A77 0215 01 A77 0216 01 A
In corner seating unit (optional)
Call device, e.g. Call switch 77 0211 00 A
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 53
9. Room types
9.1.4 Patient room: Light switching
Connection socket combi (70 0424 00) and Connection socket combi, bedhead unit (70 0434 00) have a socket for the patient handset (74 0747 00). With the patient handset (74 0747 00) the room light and the reading light can be switched on and of.
Connection socket combi (70 0424 00) and Connection socket combi, bedhead unit (70 0434 00) have a socket for a pear push witch. Connection socket with call switch (70 0171 03) and Con-nection socket with call switch, bedhead unit (70 0171 50) have two sockets for pear push switch-es. With the pear push switch incl. call and light switch (70 0710 0x) the room light or the reading light can be switched on and off.
Pulse relay (electronic)
EFE 005900; ELTAKO ES75-100-12…24V UC; ELTAKO, ES61-8 …230V UC; ELTAKO, ESR61NP-230+UC (pulse relay and switching relay)
Pulse relay (mechanical) *)
ELTAKO S91-100-24VDC
*) For use of mechanical relays a free-wheeling diode is required.
Tab. 9: Usable relays for light switching
70 0424 00
OSYnet + Ip OSYnet + Ip
Ie
IePA system (100 V) on-siteSystème de diffusion musique fourni par le client
ELA-Anlage bauseits
Room light on/offRaumlicht ein/aus
Éclairage d‘ambiance marche/arrêt
Leselicht ein/ausReading light on/off
Éclairage de lecture marche/arrêt
RANIs
24 V DC
Impulsdauer 150 msPulse duration 150 msDurée d‘impulsion 150 ms
54 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.1.5 Patient room: Light dimming
Connection socket combi universal (70 0449 00) und Connection socket combi, bedhead unit, universal (70 0448 00) have a socket for Patient handset universal (74 0748 00) and a socket for a pear push switch. With the Patient handset universal (74 0748 00) the room light and the reading light can be controlled (on/off, dimming). With the pear push switch incl. call and light switch (70 0710 0x) the room light or the reading light can be controlled (on/off, dimming). The outputs for light control provide a 24 V signal for the length of time the light switch remains pressed. The outputs may be loaded with 60 mA. The dimming feature requires suitable dimmable ballasts. The control voltage is 24 V DC. For example with DALI interface.
In combination with RAN interface universal (70 0848 00) two external actuators can be controlled by the patient handset universal (74 0748 00) (connected to an connection socket combi universal (70 0449 00) or connection socket combi, bedhead unit universal (70 0448 00), e.g. for blinds up-wards and downwards. Maximum contact load: 60 mA / 24 V.
Attention! Patient handset universal (74 0748 00), connection socket combi universal (70 0449 00) and connection socket combi, bedhead unit universal (70 0448 00) cannot be used for TV control neither for TV tone / radio tone transmission.
Switching relay (electronic)
ELTAKO ER61-UC; ELTAKO ESR61NP-230+UC (pulse relay and switching relay)
Switching relay (mechanic) *)
ELTAKO R12-100-24VDC (for top-hat rail); ELTAKO R91-100-24 VDC (flush or surface mounting); FINDER 49.61-7024.4050
*) For use of mechanical relays a free-wheeling diode is required
Tab. 10:Usable relays for light dimming
70 0449 00
OSYnet + Ip OSYnet + Ip
Room light dimmingRaumlicht dimmen
Leselicht dimmenReading light dimming
Faire varier l‘intensité d‘éclairage d‘ambiance
RANIs
RAN
70 0848 00
In
In
z.B. Jalousie aufwärts/abwärtse.g. Blinds up/down
p.ex. lever/abaisser les stores
Faire varier l‘intensité d‘éclairage de lecture
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 55
9. Room types
9.1.6 Patient room: TV control
Standard TV set (open TV tone)
Connection socket combi (70 0424 00) and Connection socket combi, bedhead unit (70 0434 00) allow TV control in combination with Patient handset (74 0747 00) and RAN interface (77 0840 00).
IR TV control module universal (70 0360 10) allows the control of standard TV sets using infrared signals. Additionally needed: kit for IR TV control module (70 0360 20), addressing plug for IR TV control module universal (70 0360 30) and one-time TV control module programming service (70 0360 50).
Note: No tone transmission to patient handset.
Data
70 0424 00
OSYnet + Ip OSYnet + Ip
Ie
Ie
PA system (100 V) on-siteSystème de diffusion musique fourni par le client
ELA-Anlage bauseits
RAN
Ia
TV74 0747 00
Daten
Données00 0280 40
70 0360 20
70 0360 10 IR
77 0840 00
In
56 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.1.7 Patient room: TV control
Standard TV set with tone transmission to Patient handset
Connection socket combi, TVL (70 0424 50) and Connection socket combi, bedhead unit, TVL (70 0434 50) allow TV control in combination with Patient handset (74 0747 00), RAN interface (77 0840 00) and IR TV control module universal Audio (70 0360 11).
Attention! These connections sockets are used only for this application.
IR TV control module universal Audio (70 0360 11) allows the control and tone transmission from standard TV sets using infrared signals. Additionally needed: kit for IR TV control module Audio (70 0360 21), addressing plug for IR TV control module (70 0360 30) and one-time TV control module programming service (70 0360 50).
Data
70 0424 50
OSYnet + Ip OSYnet + Ip
Ie
Ie
PA system (100 V) on-siteSystème de diffusion musique fourni par le client
ELA-Anlage bauseits
RAN
Ia
TV74 0747 00
Daten
Données00 0280 40
70 0360 21
70 0360 11 IR
77 0840 00
In
Ia2Ton
SoundSon
SCART
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 57
9. Room types
9.1.8 Patient room: TV control
Hospital LCD TV, professional
Connection socket combi (70 0424 00) and Connection socket combi, bedhead unit (70 0434 00) allow TV control in combination with Patient handset (74 0747 00) and the RAN interface (77 0840 00). TV sets are available in different sizes.
For the programming per project one TV installation kit (74 7002 56/XX*) required. Note: XX* stand for the current year, that means for example. 74 7002 56/13 for 2013.
The TV sets are prepared for standard VESA wall mounts.
Three different wall mounts can be ordered from Tunstall (74 7002 80, 74 7002 81, 74 7002 82).
Data
70 0424 00
OSYnet + Ip OSYnet + Ip
Ie
Ie
PA system (100 V) on-siteSystème de diffusion musique fourni par le client
ELA-Anlage bauseits
RAN
Ia
TV74 0747 00
Daten
Données00 0280 4077 0840 00
In
Ia2Ton
SoundSon
SCART
74 7005 26/XX* (26“)74 7005 32/XX* (32“)
58 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.1.9 Patient room: Separate shower and WC
Separate call cancelling for each cubicle; collective room lamp (77 0170 00) in corridor and sep-arate room lamps (77 0170 01) in room (channel encoding) with additional display for each cubi-cle. Maximum of 7 channels for each ComTerminal.
Channel numbers 1 - 6 can be used as bed numbers 1 - 6.
70 0434 00
70 0424 00
77 0510 00
77 0170 00
74 0747 00
74 0747 00
77 0211 01 A
OSYnet + Ip OSYnet + Ip
77 0215 01 A
In
Is
Is
In In
Ie
Ie
77 0213 00 A
77 0213 00 A
77 0212 00 A77 0215 01 A
In
77 0170 01
77 0170 01
In In
77
666
7
6
0
0 = Kanalnummer 0= Channel number 0= Numéro de canal 0
0
IePA system (100 V) on-siteSystème de diffusion musique fourni par le client
ELA-Anlage bauseits
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 59
9. Room types
9.2 Function room
For required back boxes and connectors refer to page 68. For cable legend see page 71.
Per room
ComTerminal Flamenco 77 0510 00
Room lamp for display of all call types and presence states:e.g. Room lamp, 3 sections
77 0170 00
77 0510 00
77 0170 00
OSYnet + Ip OSYnet + Ip
In
60 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.3 Ward bathroom
9.3.1 Ward bathroom with speech, with ComTerminal
Per room
ComTerminal Flamenco 77 0510 00
Room lamp for display of all call types and presence states:e.g. Room lamp, 3 sections
77 0170 00
For each bath / WC
Pull cord call switch, suitable for shower, WCCall switch, suitable for washbasinPneumatic call switch, suitable for bath tubs
77 0215 00 A77 0211 00 A77 0216 00 A
77 0510 00
77 0170 00
OSYnet + Ip OSYnet + Ip
In
In
InIn
In
77 0211 00 A
77 0215 00 A 77 0216 00 A
77 0211 00 A
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 61
9. Room types
9.3.2 Ward bathroom without speech, with ControlTerminal
Per room
Optional:ControlTerminal FlamencoControlTerminal Flamenco with doorplate
77 0550 0077 0551 00
ControlTerminal installation kit 77 0960 00
ControlTerminal ConfigSet (only one is required per nurse call system)
77 0920 00
Staff presence combination with call tone 77 0219 00
For each bath / WC
Pull cord call switch, suitable for shower, WCCall switch, suitable for washbasinPneumatic call switch, suitable for bath tub
77 0215 00 A77 0211 00 A77 0216 00 A
77 0550 00
OSYnet + Ip OSYnet + Ip
In
In
InIn
In
77 0211 00 A
77 0215 00 A 77 0216 00 A
77 0211 00 A
77 0219 00 A
62 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.4 Nurse station
9.4.1 Ward console ComStationBUS-C
Per room
ComStationBUS-C 77 0605 50
Connection socket ComStation 74 0452 30
Room lamp universal, 2 sections 77 0182 10
OSYnet + Ip OSYnet + Ip
In
74 0452 30
77 0605 50
77 0182 10
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 63
9. Room types
9.4.2 Ward console ComStationCT Flamenco
For required back boxes and connectors refer to page 68. For cable legend see page 71.
Per room
ComStationCT Flamenco 77 0606 00
Connection socket ComStation 74 0452 30
Room lamp for display of all call types and presence states: e.g. Room lamp, 3 sections
77 0170 00
OSYnet + Ip OSYnet + Ip
In
77 0170 00
74 0452 30
77 0606 00
64 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.4.3 Ward console ComStationPC
Per room
ComStationPC 77 0602 00
Connection socket ComStationPC 74 0452 60A
Room Lamp universal, 2 sections 77 0182 10
PrimusGlobal+ System set-up & configuration 77 0790 00
PrimusGlobal+ Project data up to 36 rooms, standardor layout.
77 0790 0177 0790 02
OSYnet + Ip OSYnet + Ip
In
74 0452 60A
77 0602 00
77 0182 10
+ 77 0790 00+ 77 0790 02
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 65
9. Room types
9.4.4 Nurse station without speech, ComStationT Flamenco
For required back boxes and connectors refer to page 68. For cable legend see page 71.
Per room
ComStationT Flamenco 77 0606 20
Connection socket ComStation 74 0452 30
Room lamp for display of all call types and presence states: e.g. Room lamp, 3 sections
77 0170 00
OSYnet + Ip OSYnet + Ip
In
77 0170 00
74 0452 30
77 0606 20
66 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.5 Corridor
Corridor displayThe corridor display Alpha 16 (77 0150 00) or corridor display Alpha, double-sided (77 0160 00) is directly connected to thegroup bus OSYnet.
Group lamps, Direction lamps4 direction lamps (77 0111 02) or group lamps for 4 wards (77 011X 02) can be con-nected per OSYlink-Group lamp (77 0802 00).
Door entry speakerTo each OSYlink-Door entry speaker (77 0801 00) one door entry speaker (77 0350 00) can be connected.
Loudspeaker with announcement interfaceTo each OSYlink-Announcement (77 0804 00) a maximum of 5 loudspeakers with announcement interface (05 0024 01) can be connected.
Devices or technical equipment from other makes
Connection of devices or technical equipment from other makes via OSYlink-Universal (77 0803 00).
OSYnet + Ip OSYnet + Ip
77 01x0 00
OSYnet + Ip OSYnet + Ip
77 0802 00 A2
A177 0111 02
77 0112 02
OSYnet + Ip OSYnet + Ip
77 0801 00
77 0350 00
OSYnet + Ip OSYnet + Ip
77 0804 00
05 0024 01
OSYnet + Ip OSYnet + Ip
77 0803 00
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 67
9. Room types
9.6 Back boxes, connectors
Back boxes
Connectorsolid wall
partition wall
1-g
an
g1
70
100
00
2-g
an
g1
70
410
00
1-g
an
g1
75
100
00
2-g
an
g1
75
400
00
70
080
700
77 0211 00...... = A, C, F
Call switch
77 0211 01...... = A, C, F
Call switch/WC
77 0212 00...... = A, C, F
Staff presence switch
77 0213 00... ... = A, C, F
Cancel switch/WC
77 0214 00...... = A, C, F
Cardiac alarm switch
77 0215 00...... = A, C, F
Pull cord call switch
77 0215 01...... = A, C, F
Pull cord call switch/WC
77 0216 00...... = A, C, F
Pneumatic call switch
77 0216 01...... = A, C, F
Pneumatic call switch/WC
77 0217 00...... = A, C, F
Call switch/WC with can-cel switch
77 0218 00...... = A, C, F
Call switch with privacy switch
77 0219 00...... = A, C, F
Staff presence combina-tion with call tone
70 0171 03 Connection socket with call switch
70 0807 01
70 0171 50 Connection socket with call switch, bedhead unit
built-in medical supply unit
00 0211 37
68 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
70 0424 00 Connection socket combi
70 0424 50 Connection socket combi, TVL
70 0449 00 Connection socket combi universal
70 0434 00 Connection socket combi, bedhead unit
built-in medical supply unit
70 0434 50 Connection socket combi, bedhead unit, TVL
70 0448 00 Connection socket combi, bedhead unit Universal
74 0452 30 Connection socket Com-Station
74 0452 60A Connection socket Com-
StationPC
77 0510 00 ComTerminal Flamenco
77 0520 00 RoomTerminal Fla-menco
77 0550 00 ControlTerminal Fla-menco
77 0960 00
77 0551 00 ControlTerminal Fla-menco with doorplate
77 0960 00
77 0111 02 Direction lamp
77 0112 02 Group lamp, 2 groups
77 0113 02 Group lamp, 3 groups
77 0114 02 Group lamp, 4 groups
Back boxes
Connectorsolid wall
partition wall
1-g
ang
170
100
00
2-g
ang
170
410
00
1-g
ang
175
100
00
2-g
ang
175
400
00
700
807
00
A2
A1
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 69
9. Room types
77 0170 00 Room lamp, 3 sections
77 0170 01 Room lamp cardiac alarm, WC
77 0170 10 Room lamp, 4 sections
77 0171 00 Room lamp, 3 sections, with doorplate
77 0171 10 Room lamp, 4 sections, with doorplate
77 0175 00 Room lamp, 3 sections, glass decor
77 0175 01 Room lamp cardiac alarm, WC, glass decor
77 0175 10 Room lamp, 4 sections, glass decor
77 0182 10 Room lamp universal, 2 sections
70 0807 07
77 0185 20 Room lamp universal, 2 sections, glass decor
70 0807 07
77 4000 00 OSYnet-Y-Repeater-Opto
77 0950 00
Back boxes
Connectorsolid wall
partition wall
1-g
ang
170
100
00
2-g
ang
170
410
00
1-g
ang
175
100
00
2-g
ang
175
400
00
700
807
00
70 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
9. Room types
9.7 Cable legend
To simplify the handling of installation plans, Tunstall GmbH has introduced an ex-panded cable legend. The cables are organised according to their application areas. Relevant types of cables are allocated to specific application areas. These shall be considered as minimum requirements.
Marking Designation Cable type
Ia General cables IY(ST)Y 2x2x0.8
Ia2 General cables IY(ST)Y 2x2x0.6
Ia3 General cables IY(ST)Y 3x2x0.6
Ia4 General cables IY(ST)Y 4x2x0.6
Ia5 General cables IY(ST)Y 4x2x0.8
OSYnet Group bus OSYnet Recommended cables:CAT7 (22 AWG) with diameter = 0.64 mmIY(ST)Y 4x2x0.8 with diameter = 0.8 mm
Optional cables:CAT5 (23 AWG) with diameter = 0.57 mm CAT6 (23 AWG) with diameter = 0.57 mmCAT7 (23 AWG) with diameter = 0.57 mmIY(ST)Y 4x2x0.6 with diameter = 0.6 mm
Ie Entertainment cables 2x IYY per channelor similar cables (1 double wire required for each programme)
In Room bus RAN IY(ST)Y 2x2x0.8
Ip Power cable NYM 2x2.5 mm²
Is Speech cable plus room bus RAN
2x IY(ST)Y 2x2x0.8
Tab. 11: Cable legend
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 71
9. Room types
72 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.1 Signal lamps, corridor displays
Functions Order No.
Room lamp, 3 sections
Signal lamp with three light sections for visual signalling of all call types and presence states (2 staff groups).
LED red: all call types
LED green: presence 1
LED yellow: presence 2
Connection to room bus (RAN)
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0170 00
Room lamp, 3 sections, with doorplate
as 77 0170 00, but additionally with label field for room designation.
Dimensions (HxWxD): 190 x 150 x 40 mmLabel field (HxW): approx. 70 x 92 mm
77 0171 00
Room lamp, 3 sections, glass decor
as 77 0170 00, but with decorative glass frame.
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0175 00
Room lamp cardiac alarm, WC
Signal lamp with three light sections as sup-plement to room lamp 77 0170 00 or 77 0171 00 for visual signalling of cardiac alarm and WC calls.
LED blue: cardiac alarm
LED blue: cardiac alarm
LED white: WC call
Connection to room bus (RAN)
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0170 01
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 73
10. Product overview
Room lamp Alarm, WC, glass decor
as 77 0170 01, but as supplement to room lamp 77 0175 00.
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0175 01
Room lamp, 4 sections
Signal lamp with four light sections for visual signalling of all call types and presence states (2 staff groups) and for WC call as sin-gle indication.
LED red: calls
LED green: presence 1
LED yellow: presence 2
LED white: WC call
Connection to room bus (RAN)
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0170 10
Room lamp, 4 sections, with doorplate
as 77 0170 10, but additionally with label field for room designation.
Dimensions (HxWxD): 190 x 150 x 40 mmLabel field (HxW): approx. 70 x 92 mm
77 0171 10
Room lamp, 4 sections, glass decor
as 77 0170 10, but with decorative glass frame.
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0175 10
Functions Order No.
74 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Room lamp universal, 2 sections
Signal lamp with two light sections for visual signalling of staff presence 1 and telephone calls as individual indication.
No connection to room bus (RAN).
For use e.g. in combination wit ComStation-BUS-C or ComStationPC.
LED green: presence 1
LED white: telephone call
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0182 10
Room lamp universal, 2 sections, glass decor
as 77 0182 10, but with decorative glass frame.
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0185 20
Doorplate universal
Doorplate without light sections, for room designation.
Dimensions (HxWxD): 110 x 150 x 40 mmLabel field (HxW): approx. 70 x 92 mm
77 0189 00
Direction lamp
Display of directions to calls.
LED module red
LED module green
Arrows to customer specifications.
Connection to OSYlink-Group lamp (77 0802 00).
Dimensions (HxWxD): 80 x 86 x 70 mm
77 0111 02
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 75
10. Product overview
Group lamp, 2 groups
Group-related display of calls for 2 groups with two light fields for each group (green, red).
2 LED modules green
2 LED modules red
Inscription to customer specifications.
Connection to OSYlink-Group lamp (77 0802 00).
Dimensions (HxWxD): 80 (each lamp) x 86 x 70 mm
77 0112 02
Group lamp, 3 groups
as 77 0112 02, but for 3 groups
77 0113 02
Group lamp, 4 groups
as 77 0112 02, but for 4 groups
77 0114 02
Corridor display Alpha 16
Display with alphanumerics for calls and sys-tem information. Tone generator for acoustic signals, loudspeaker for announcements.
For mounting in corridors and staff rooms.
Single-sided design
16 digits, alphanumeric
Connection cable with free wire ends for connection to group bus (OSYnet).
Dimensions w/o mounting bracket (HxWxD): 120 x 765 x 35 mm
77 0150 00
Corridor display Alpha 16, double-sided
as 77 0150 00, but double-sided design.
Dimensions w/o mounting bracket (HxWxD): 120 x 765 x 125 mm
77 0160 00
Functions Order No.
76 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.2 Switches
Functions Order No.
Call switch
Water protected switch for raising calls.
2 call buttons (red)
Connection to Room Bus (RAN)
Dimensions (HxWxD): 91 x 91 x 36 mm
77 0211 00 A
77 0211 00 A
Call switch
as 77 0211 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 36 mm
77 0211 00 C
Call switch
as 77 0211 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 36 mm
77 0211 00 F
Call switch/WC
as 77 0211 00 A, but for raising WC calls / WC emergency calls.
77 0211 01 A
Call switch/WC
as 77 0211 00 C, but for raising WC calls / WC emergency calls.
77 0211 01 C
Call switch/WC
as 77 0211 00 F, but for raising WC calls / WC emergency calls.
77 0211 01 F
Staff presence switch
Water protected switch for activating pres-ence for 2 staff groups.
1 presence button staff 1 (green)
1 presence button staff 2 (yellow)
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 36 mm
77 0212 00 A
77 0212 00 A
Staff presence switch
as 77 0212 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 36 mm
77 0212 00 C
Staff presence switch
as 77 0212 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 36 mm
77 0212 00 F
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 77
10. Product overview
Cancel switch/WC
Water protected switch for cancelling WC calls and WC emergency calls.
2 cancel buttons (grey)
Acoustic signalling of forwarded calls
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 36 mm
77 0213 00 A
77 0213 00 A
Cancel switch/WC
as 77 0213 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 36 mm
77 0213 00 C
Cancel switch/WC
as 77 0213 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 36 mm
77 0213 00 F
Cardiac alarm switch
Water protected switch for raising cardiac alarms.
2 alarm buttons (blue)
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 36 mm
77 0214 00 A
77 0214 00 A
Cardiac alarm switch
as 77 0214 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 36 mm
77 0214 00 C
Cardiac alarm switch
as 77 0214 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 36 mm
77 0214 00 F
Functions Order No.
78 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Pull cord call switch
Water protected switch for raising calls via pull cord.
2 m pull cord and call handle (red) with nurse symbol
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 56 mm
77 0215 00 A
77 0215 00 A
Pull cord call switch
as 77 0215 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 56 mm
77 0215 00 C
Pull cord call switch
as 77 0215 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 56 mm
77 0215 00 F
Pull cord call switch/WC
as 77 0215 00 A, but for raising WC calls / WC emergency calls.
77 0215 01 A
Pull cord call switch/WC
as 77 0215 00 C, but for raising WC calls / WC emergency calls.
77 0215 01 C
Pull cord call switch/WC
as 77 0215 00 F, but for raising WC calls / WC emergency calls.
77 0215 01 F
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 79
10. Product overview
Pneumatic call switch
Water protected switch for raising calls by squeezing the bulb.
2 m air hose and red rubber bulb
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 56 mm
77 0216 00 A
77 0216 00 A
Pneumatic call switch
as 77 0216 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 56 mm
77 0216 00 C
Pneumatic call switch
as 77 0216 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 56 mm
77 0216 00 F
Pneumatic call switch/WC
as 77 0216 00 A, but for raising WC calls / WC emergency calls.
77 0216 01 A
Pneumatic call switch/WC
as 77 0216 00 C, but for raising WC calls / WC emergency calls.
77 0216 01 C
Pneumatic call switch/WC
as 77 0216 00 F, but for raising WC calls / WC emergency calls.
77 0216 01 F
Call switch/WC with cancel switch
Water protected switch for raising WC calls and WC emergency calls as well as for can-celling WC calls and WC emergency calls.
1 call button (red)
1 cancel button (grey)
Acoustic signalling of forwarded calls
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 36 mm
77 0217 00 A
77 0217 00 A
Call switch/WC with cancel switch
as 77 0217 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 36 mm
77 0217 00 C
Call switch/WC with cancel switch
as 77 0217 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 36 mm
77 0217 00 F
Functions Order No.
80 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Call switch with privacy switch
Water protected switch for raising calls and for local switching the privacy function.
1 call button (red)
1 privacy button (grey)
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 36 mm
77 0218 00 A
77 0218 00 A
Call switch with privacy switch
as 77 0218 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 36 mm
77 0218 00 C
Call switch with privacy switch
as 77 0218 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 36 mm
77 0218 00 F
Staff presence combination with call tone
Water protected switch for activating staff presence and for raising calls
1 call button (red)
1 presence button staff 1 (green)
Acoustic signalling of forwarded calls
Connection to room bus (RAN)
Dimensions (HxWxD): 91 x 91 x 36 mm
77 0219 00 A
77 0219 00 A
Staff presence combination with call tone
as 77 0219 00 A, but with glass frame.
Dimensions (HxWxD): 107 x 107 x 36 mm
77 0219 00 C
Staff presence combination with call tone
as 77 0219 00 A, but with narrow frame.
Dimensions (HxWxD): 80 x 80 x 36 mm
77 0219 00 F
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 81
10. Product overview
10.3 Room terminals
Functions Order No.
ComTerminal Flamenco
Communication terminal with duplex speech feature, for use in patient rooms, staff rooms and function rooms.
Innovative control panel made of real glass with integrated sensors and display elements for easy and intuitive operation
Surface mounting, plug-in electronic com-ponents
Connection to group bus OSYnet
Red call button with symbol, location light and reassurance light
Blue alarm button with symbol, location light and reassurance light, configurable
Green large presence button for staff 1, with reminder light
Yellow large presence button for staff 2, with reminder light
4 function keys with situation related func-tions
Graphic display, backlit, 128x64 dot ma-trix
High-quality loudspeakers and high-end electret microphone
Configuration menu for selection of room functions and for system parameter set-ting
Integrated function monitoring feature with status indication
International version, language selectable via configuration
Moisture-protected casing
Close and smooth surface, easy to clean and to disinfect
No data loss during power failure
Possible mixed operation in Flamenco systems without speech
Room bus (RAN) for connection of further user elements and displays
Dimensions (HxWxD): 205 x 110 x 34 mm
77 0510 00
82 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
RoomTerminal Flamenco
Room terminal for use in patient rooms, staff rooms and function rooms, without speech communication.
Surface mounting, plug-in electronic com-ponents
Connection to group bus OSYnet
Red call button with symbol, location light and reassurance light
Blue alarm button with symbol, location light and reassurance light
Green large presence button for staff 1, with reminder light
Yellow large presence button for staff 2, with reminder light
4 function keys with situation related func-tions
Attention tone for announcements
Call re-activation after a programmed time
Graphic display, backlit, 128x64 dot ma-trix
Configuration menu for selection of room functions and for system parameter set-ting
Integrated function monitoring feature with status indication
International version, language selectable via configuration
Moisture-protected casing (IP 54)
Close and smooth user surface, easy to clean and to disinfect
No data loss during power failure
Possible mixed operation in Flamenco systems with speech
Room bus (RAN) for connection of further user elements and displays
Dimensions (HxWxD): 205 x 110 x 34 mm
77 0520 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 83
10. Product overview
ControlTerminal Flamenco
ControlTerminal for patient rooms, staff rooms and function rooms, without speech communication. The ControlTerminal includes a room lamp and is installed in the corridor instead of an additional room lamp.
Surface mounting
Connection to group bus OSYnet
No data loss during power failure
4 light sections:LED red: callsLED green: staff presence 1LED yellow: staff presence 2LED white: WC call
Possible mixed operation in Flamenco systems with speech
Room bus (RAN) for connection of further user elements and displays
Dimensions (HxWxD): 110 x 150 x 40 mm
77 0550 00
ControlTerminal Flamenco with doorplate
as 77 0550 00, but additionally with label field for room designation.
Dimensions (HxWxD): 190 x 150 x 40 mmLabel field (HxW): approx. 70 x 92 mm
77 0551 00
Functions Order No.
84 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.4 Connection sockets
Functions Order No.
Connection socket with call switch
Connection socket for two call devices with call button and extra external call input.
1 red call button with reassurance light for raising calls
2 identical sockets for connection of plug-in call devices (pear push switch, diagnos-tic devices, etc.)
Additional external call input for connect-ing a call device (normally closed contact)
Pulse output for light switching: 150 ms, 24 V DC, max. 200 mA
Connection to room bus (RAN)
Dimensions (HxWxD): 90 x 90 x 29 mm
70 0171 03
Connection socket with call switch, bedhead unit
Connection socket for two call devices with call button and extra external call input.
1 red call button with reassurance light for raising calls
2 identical sockets for connection of plug-in call devices (pear push switch, diagnos-tic devices, etc.)
1 backside connection for an additional call button with location and reassurance light. Normally closed or normally open contact can be set by DIP switch.
2 outputs for light switching: 24 V DC, max. 200 mA
Connection to room bus (RAN)
Dimensions (HxWxD): 70,5 x 70,5 x 28 mm
70 0171 50
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 85
10. Product overview
Connection socket combi
For wall mounting. For connecting of patient units and call devices.
1 socket for patient handset (74 0747 00)
1 socket for call device (pear push switch, diagnostic unit, etc.)
Facility for connection of light switching (on/off)
5 entertainment programmes
Connection for TV sound
TV control in combination with RAN inter-face (77 0840 00)
Connection to room bus (RAN)
Dimensions (HxWxD): 90 x 181 x 10 mm
70 0424 00
Connection Socket Combi, TVL
Use only, if TV is coupled via IR TV control module universal audio!
For wall mounting. For connecting of patient units and call devices.
1 socket for patient handset (74 0747 00)
1 socket for call device (pear push switch, diagnostic unit, etc.)
Facility for connection of light switching (on/off)
5 entertainment programmes
Connection for TV sound
TV control in combination with RAN inter-face (77 0840 00)
Connection to room bus (RAN)
Dimensions (HxWxD): 90 x 181 x 10 mm
70 0424 50
Functions Order No.
86 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Connection socket combi universal
For wall mounting. For connecting of patient units and call devices.
1 socket for patient handset universal (74 0748 00)
1 socket for call device (pear push switch, diagnostic unit, etc.)
Facility for connection of light control (on/off, dimming)
Control of 2 external actuators via RAN in-terface universal (70 0848 00), e.g. blinds upwards/downwards
Dimensions (HxWxD): 90 x 181 x 10 mm
70 0449 00
Connection socket combi, bedhead unit
For installation in medical supply units. For connecting of patient units and call devices.
1 socket for patient handset (74 0747 00)
1 socket for call device (pear push switch, diagnostic unit, etc.)
Facility for connection of light switching (on/off)
5 entertainment programmes
Connection for TV sound
TV control in combination with RAN inter-face (77 0840 00)
Connection to room bus (RAN)
Dimensions (HxWxD): 181 x 131 x 37 mm
70 0434 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 87
10. Product overview
Connection socket combi, bedhead unit, TVL
Use only, if TV is coupled via IR TV control module universal audio!
For installation in medical supply units. For connecting of patient units and call devices.
1 socket for patient handset (74 0747 00)
1 socket for call device (pear push switch, diagnostic unit, etc.)
Facility for connection of light switching (on/off)
5 entertainment programmes
Connection for TV sound
TV control in combination with RAN inter-face (77 0840 00)
Connection to room bus (RAN)
Dimensions (HxWxD): 181 x 131 x 37 mm
70 0434 50
Connection socket combi, bedhead unit, universal
For installation in medical supply units. For connecting of patient units and call devices.
1 socket for patient handset universal (74 0748 00)
1 socket for call device (pear push switch, diagnostic unit, etc.)
Facility for connection of light control (on/off, dimming)
Control of 2 external actuators via RAN in-terface universal (70 0848 00), e.g. blinds upwards/downwards
Dimensions (HxWxD): 181 x 131 x 37 mm
70 0448 00
Connection Socket ComStation
Data socket for connecting a ComStationBUS-
C, ComStationCT Flamenco, ComStationT Flamenco. For wall mounting on a 2 gang back box.
Dimensions (HxWxD): 81 x 152 mm
74 0452 30
Functions Order No.
88 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Connection Socket ComStationPC
Data socket for connecting a ComStationPC. For wall mounting on a 2 gang back box.
Dimensions (HxWxD): 81 x 152 mm
74 0452 60A
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 89
10. Product overview
10.5 Patient units
Functions Order No.
Patient handset
Patient handset with duplex speech facility. Designed for use at the patient bed
Ergonomic housing with all-round protec-tive edge
Protection class (IP54)
Automatic switching of volume in relation to the type of usage
Audio transmission (TV/Radio) discrete or open via loudspeaker
TV control in combination with RAN inter-face (77 0840 00)
Clear inscription with simple symbols
Excellent voice quality, high-quality Elec-tret microphone and high-quality loud-speaker
Red call button with reassurance light and integrated location light
Yellow light button for reading light (on/off)
Yellow light button for room light (on/off)
2 buttons for control of the entertainment programmes (TV/Radio)
2 buttons for volume control (TV/Radio)
2 buttons for TV control, status indication
1 ear phone socket (3.5 mm jack) for con-ventional ear phones (32 Ohm), e.g. 70 0801 00
Connection cable with rugged connector, cable length 2.5 m
Wall fixing with patient handset bracket (70 0800 00) possible
Weight: 297 g
Dimensions (HxWxD): 195.5 x 52 x 25 mm
74 0747 00
90 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Patient handset universal
Universal patient handset with duplex speech facility. Designed for use at the patient bed
Ergonomic housing with all-round protec-tive edge
Protection class (IP54)
Clear inscription with simple symbols
Excellent voice quality, high-quality Elec-tret microphone and high-quality loud-speaker
Red call button with reassurance light and integrated location light
Yellow light button for reading light (on/off, dimming)
Yellow light button for room light (on/off, dimming)
2 buttons for control of external actuators in connection with RAN interface univer-sal (70 0848 00), e.g. blinds upwards/downwards
Connection cable with rugged connector, cable length 2.5 m
Wall fixing with patient handset bracket (70 0800 00) possible
Weight: 297 g
Dimensions (HxWxD): 195.5 x 52 x 25 mm
74 0748 00
Pear push switch incl. call and light switch, 2 m connection cable
Humidity protected call and light switch for raising calls and reading light control.
Connection to socket for call devices con-tained in connection sockets.
Dimensions (HxW): 60 x 20 mm
70 0710 00
Pear push switch incl. call and light switch, 4 m connection cable
as 70 0710 00, but 4 m connection cable.
Dimensions (HxWxD): 60 x 20 mm
70 0710 01
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 91
10. Product overview
Pear push switch incl. 2 call switches,2 m connection cable
Humidity protected call switch for raising calls.
Connection to socket for call devices con-tained in connection sockets
Dimensions (HxW): 60 x 20 mm
70 0711 00
Pear push switch incl. 2 call switches, 4 m connection cable
as 70 0711 00, but 4 m connection cable.
70 0711 01
Sound detector
Sound detector for acoustic monitoring of rooms leading to automatic call activation in case of any noises. Normal conversation will not activate a call.
Sensitivity and noise duration can be adjusted.
Connection to socket for call devices con-tained in connection sockets
Dimensions (HxWxD): 96 x 48 x 24 mm
70 0790 00
1 Channel radio receiver
UHF 1-channel switching receiver for receiv-ing of signals from associated UHF radio transmitters.
NOTE: The radio transmission is not moni-tored, and the system with transmitter and receiver may be used only as a complemen-tary element in combination with a normal nurse call system.
Call is raised when unit is disconnected
Integrated antenna
Raised call indicator
Status control
Connection to socket for call devices con-tained in connection sockets
Dimensions (HxWxD): 96 x 48 x 24 mm
70 0831 00
Functions Order No.
92 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
1 Channel hand held transmitter
Splash-proof 1 channel transmitter with pearl-formed shoulder-band of synthetic material for wireless activation of calls within a room.
Trigger button
Optical function indication
Usable in combination with radio receiver 70 0831 00.
Protection class: IP 67
Weight: 38 g
Radio frequency: 433.92 MHz
Dimensions (HxWxD): 60 x 40 x 15 mm
70 0831 01
1 Channel bracelet transmitter
Splash-proof 1 channel bracelet transmitter, watch-formed, with synthetic watch strap for wireless activation of calls within a room.
Trigger button
Optical function indication
Usable in combination with radio receiver 70 0831 00.
Protection class: IP 57
Weight: 25 g
Radio frequency: 433.92 MHz
Diameter: 42 mm, height: 16 mm
70 0831 02
Diagnostic connection cable
For connection of electrical medical devices to connection sockets. Packing unit = 5
Connection to socket for call devices con-tained in connection sockets
Cable length 2 m
70 0812 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 93
10. Product overview
Sensor mat for connection socket
Large mat for triggering of calls by stepping on it or by pressing it. The mat is placed e.g. in front of the bed. If the patient leaves the bed or falls from the bed onto the mat, a call is triggered within the nurse call system.
Large sensor area
Normally closed contact
Disconnection call
Fault monitoring
Water-proof
PVC, easy to clean
Connection to socket for call devices con-tained in connection sockets
Dimensions (W x D): 1200 x 500 mmThickness of the stepping area: 4 mm
Z 00 8002 02
Functions Order No.
94 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.6 Call handling consoles
Functions Order No.
ComStationBUS-C
Ward console for ward nurse station for answering and handling calls and to support nursing service.
Microphone, loudspeaker and handset for speech communication
Call answering and call handling
Automatic answering according to priority
Announcements
Enabling and disabling of ward coupling
Enabling and disabling of shifts
Display of system messages
Handset or hands-free speech
5.7 inch multi-functional colour display, resolution 640x480, LED illuminated
Operation using select buttons as soft keys
Plastic foil keypad
Desktop or wall mounting
Output for staff presence
Output for external call tone
Connection to the group bus (OSYnet) via Connection Socket ComStation
Dimensions (HxWxD): 55 x 273 x 185 mm
77 0605 50
ComStationPC
Screen based version of a ward console for decentralised processing of all functions within a ward. Prepared for connection to the group bus (OSYnet).
Speech communication via desktop speech unit with integrated handset.
Interface for system computer
System computer (80 6010 00)
Monitor
77 0602 00
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 95
10. Product overview
ComStationPC
- continued -
Display and processing of prepared ward functions:
Calls, Emergency calls, Alarms
Indication of call location
Staff presence states
Bed identification 1 – 6
Call status (fresh / answered)
Additional information:
Date / Clock time
Speech control and speech status
Technical system messages
Operating modes:
Ward mode
Ward coupling
Freely defined operating modes
Announcements:
Flexible installation of different announce-ment circuits, ordered by rooms, wards or areas as individual or general announce-ments to all rooms or to rooms with active presences states only.
Care data:
To support call handling, a local database is provided. Here, person-related care data are administrated. Data administration is effected directly from the console workstation.
Call recording:
All call data, staff presence messages and system events can be recorded. The data can be filtered and sorted by different criteria.
Software administration contract:
The acquiring of the system software Primus-Global+ is combined with placing of a soft-ware administration contract with costs.
77 0602 00
Functions Order No.
96 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
ComStationCT Flamenco
Desktop terminal for the nurse station for handling and processing of calls, raising of calls or alarms to call for additional staff. Ena-ble and disabling ward couplings and shifts (zone nursing).
Innovative control panel made of real glass with integrated sensors and display elements for easy and intuitive operation
4 function keys with situation related func-tions
Red call button with symbol, location light and reassurance light
Blue alarm button with symbol, location light and reassurance light, configurable
Green large presence button for staff 1, with reminder light
Yellow large presence button for staff 2, with reminder light
Moisture-protected casing
Close and smooth surface, easy to clean and to disinfect
Indication of nurse call system faults with fault location
Possible mixed operation in Flamenco systems without speech
Room bus (RAN) for connection of further user elements and displays
International version, language selectable via configuration
Integrated configuration menu
Possible mixed operation in Flamenco systems without speech
Integrated interface for room bus (RAN)
Connection to group bus (OSYnet) via connection socket ComStation (74 0452 30)
2.5 m connection cable with strain relief
Dimensions (HxWxD): 30–120 x 110 x 240 mm
77 0606 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 97
10. Product overview
ComStationT Flamenco
Desktop terminal without speech communica-tion for the nurse station for displaying and acknowledging of calls, raising of calls or alarms to call for additional staff. Enable and disabling ward couplings and shifts (zone nursing).
Innovative control panel made of mem-brane switches and display elements for easy and intuitive operation
4 function keys with situation related func-tions
Red call button with symbol, location light and reassurance light
Blue alarm button with symbol, location light and reassurance light
Green large presence button for staff 1, with reminder light
Yellow large presence button for staff 2, with reminder light
Close and smooth user surface, easy to clean and to disinfect
Indication of nurse call system faults with fault location
International version, language selectable via configuration
Integrated configuration menu
Possible mixed operation in Flamenco systems with speech
Integrated interface for room bus (RAN)
Connection to group bus (OSYnet) via connection socket ComStation (74 0452 30)
2.5 m connection cable with strain relief
Dimensions (HxWxD): 30 –120 x 110 x 240 mm
77 0606 20
Functions Order No.
98 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
ManagementCenterPC
Central console as PC console for central handling and processing of all functions within the nurse call system. Prepared for connection to the OSY-ControlCenter.
Speech communication via desktop speech unit with integrated hand-held re-ceiver.
Interface for system computer
System computer (80 6010 00)
Monitor
Indication and processing of functions which are prepared for the nurse call system (selec-tion):
Calls, Emergency calls, Alarms
Indication of call location
Staff presence states
Bed identification 1 – 6
Call status (fresh / answered)
Additional information:
Speech control and speech status
Technical system messages
Messages from external systems via in-terfaces
Control of operating modes:
Central mode / Ward mode
Ward coupling
Mixed operating modes, freely defined
Announcements:
Flexible preparation of different announce-ment circuits sorted by rooms, wards, areas as individual or general announcements to all rooms or only to rooms with active presence states.
Multi-station operation:
The connected wards can be flexibly allo-cated to several console workstations. Oper-ators may choose a distribution to several locations or a handover (reduced work load during night shift) from several consoles to one console.
77 0610 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 99
10. Product overview
ManagementCenterPC
- continued -
Care data:
To support call handling, a local database is provided with person-related care data. Data administration is effected directly at the con-sole.
Call recording:
All call data, staff presence states and system events can be recorded. Filtering and sorting of these data can be executed acc. to a com-prehensive range of criteria.
Additional software modules are available
Software administration contract:
The acquiring of the system software Primus-Global+ is combined with placing of a soft-ware administration contract with costs.
77 0610 00
ManagementCenterPC Push buttons
Central console with push buttons and inte-grated PC console for central handling and processing of all functions in the nurse call system. Designed as PC workstation with additional push buttons. Adapted to the size and scope of the relevant project. Control arrangement can be freely positioned in a room. Prepared for connection to the OSY-ControlCenter.
Ward fields as module with 36 push keys each and 3 allocated optical indicators for display of calls and 2 presence states for simple handling of communication tasks.
Speech communication via desktop speech unit with integrated hand receiver.
Interface to system computer
System computer (80 6010 00)
Monitor
Additionally the ManagementCenterPC push buttons provides all functions, that are described for the ManagementCenterPC (77 0610 00).
77 0620 00
Functions Order No.
100 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.7 System software and PC
Functions Order No.
PrimusGlobal+ „Call recording“
Software to support nursing documentation.
Basis:
Windows operating system
Data interface for connection to the Fla-menco nurse call system
Database for all system and customer-specific data
Software interface for remote administra-tion of the system
User interface for the nurse call system.
Functions:
Permanent recording of all system events (calls, staff presences, etc.) incl. date, clock time and appropriate information on data source, such as ward and room designation
Selection of locations to be analysed (wards, rooms, etc.)
Filtering of data acc. to event time
Filtering of data acc. to type of event (calls, staff presence, other events)
Filtering of data acc. to executed tasks
Selection of parameters to be shown
Sorting of data acc. to different criteria
Printing function
Export function to standard Office packag-es in CSV format.
Software administration contract:
The acquiring of the system software Primus-Global+ is combined with placing of a soft-ware administration contract with costs.
77 0710 00
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 101
10. Product overview
PrimusGlobal+ module “Connect”
Supplement to the PrimusGlobal+ “Manage-mentCenter”. The module “Connect” provides interfaces to other systems, such as hospital information system, fire detections system and Facility Management System.
Depending on the respective application, Connect uses the appropriate system driver.
NOTE: For every application, detailed arrangements with the respective customer are required, and additional cost may accrue from development work for specific adapta-tions
77 0720 00
PrimusGlobal+ system driver HL7
Nursing and/or personal data to be used at the console of the Flamenco nurse call sys-tem can be assessed from the hospital infor-mation system (HIS). The system driver HL7 establishes the link between the hospital information system and the software family PrimusGlobal+.
77 0720 01
PrimusGlobal+ system driver FDS
Reports from the fire detection system (FDS) can also be indicated in the Flamenco nurse call system. The system driver FDS links the fire detection system with the software family PrimusGlobal+.
77 0720 02
PrimusGlobal+ system driver FMS
Fault messages from the Flamenco nurse call system can be relayed to the Facility Man-agement System and be displayed there as well. The system driver FMS links the Facility Management System and the software family PrimusGlobal+.
77 0720 03
PrimusGlobal+ system driver CUS
Customer-specific development: Other links are available on request. Various transfer protocols and transfer methods can be sup-ported.
77 0720 04
Functions Order No.
PrimusGlobal+„ManagementCenter“
PrimusGlobal+„Connect“
102 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
OSY-CC VoIP-SIP Interface
For active support of nursing this interface enables a coupling of the nurse call system to a modern PBX for mobile speech communi-cation. The coupling is realised centrally and directly to the OSY-ControlCenter.
Data exchange to a PBX or to an alarm server is realised via SIP. The speech con-nection is made via VoIP.
The PBX is physically connected via LAN.
Forwarding of call messages to a cordless telephone
Automatic redial on busy
Call location and call type are displayed in the display of the cordless telephone
Speech connection is established to the calling party
Denying the conversation is possible.
Deleting the call depending on the call sta-tus in the nurse call system.
Closing the conversation.
Due to the very different technical conditions beforehand a close agreement between the user and the supplier of the PBX must take place.
Adaptations that may be required are possi-ble after a previous common specification. They are charged depending on the amount of work.
77 0740 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 103
10. Product overview
OSY-CC DIA Interface
The interface was developed for coupling intensive care devices to the Flamenco sys-tem.
Filtered messages are received by the nurse call system and displayed there. Hereby the priorities, the display order, and the display location can be configured.
The displayed data can be received from the interface or can be assigned in a separate table and be re-defined.
The communication is realised using ESPA 4.4.4 protocol via a serial interface or a LAN connection.
Different transfer protocols and transfer methods can be supported. Depending on the amount of work additional costs for adap-tation developments may incur. The costing is made after the specification sheet was approved.
77 0741 00
OSY-CC FDS Interface
The interface is designed for coupling a fire detection system (FDS) to the Flamenco nurse call system.
Filtered messages are received by the nurse call system and displayed there. Hereby the priorities, the display order, and the display location can be configured.
The displayed data can be received from the interface or can be assigned in a separate table and be re-defined.
The communication is realised using ESPA 4.4.4 protocol via a serial interface RS232.
Different transfer protocols and transfer methods can be supported. Depending on the amount of work additional costs for adap-tation developments may incur. The costing is made after the specification sheet was approved.
77 0742 00
Functions Order No.
104 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
PrimusGlobal+ ”System set-up and configuration”
Necessary services for the implementation of PrimusGlobal+ software to be performed by Tunstall GmbH.
Prerequisite is the basic installation and the preparation with the relevant function mod-ules and system drivers. Hardware is pre-pared in compliance with local demands and fully tested.
Scope of performance:
Installation of the operating system
Preparation of the function modules, sys-tem modules and drivers
Preparation of hardware and function check
Preparation of operating and control structure and user menu
Comprehensive function checks and doc-umentation of configuration
Further to the system installation and configu-ration, the individual rooms must be config-ured to comply with the project specifications. Relevant data and designations for buildings, wards, and rooms are prepared. Individual display and indicating elements for rooms and wards are placed and activated as desired. Optional use of standard graphic ele-ments or planview graphics:
77 0790 00
PrimusGlobal+ ”Project data for up to 36 rooms, standard”
Input of project-specific data
Use of standard graphics for the display level
77 0790 01
PrimusGlobal+ ”Project data for up to 36 rooms, layout”
Input of project-specific data
Use of graphic CAD data for planview
Adapting of planview for use as display level
77 0790 02
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 105
10. Product overview
SystemOrganizer
Software for comfortable planning and config-uring of Flamenco nurse call systems. Com-prehensive range of settings for simple use and operation.
Operation:
Interactive and user-guided application
5 user levels, password protected
3 display levels (physical, electric, organi-sational)
Access to all system and project data via tree structure
Use on any computer with system access, also via remote access
Organisation of several projects and ar-chiving of data
Read out of project configuration of cur-rent project, presentation of current con-figuration
Plausibility check during data input
77 0750 00
Laser printer b/w
High-quality laser printer.
Design and version in compliance with cur-rent standard equipment. Further details on request.
80 5015 00
System computer
System computer for operation and control of a ManagementCenter and for the use of inde-pendently operating software applications.
Design and version in compliance with cur-rent standard equipment. Further details on request.
80 6010 00
Functions Order No.
106 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Monitor 17”
High-quality flat-screen. Designed for desk-top use or for installation into a Management-Center.
Design and version in compliance with cur-rent standard equipment. Further details on request.
80 6047 00
Monitor 19”High-quality flat-screen. Designed for desk-top use or for installation into a Management-Center.
Design and version in compliance with cur-rent standard equipment. Further details on request.
80 6049 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 107
10. Product overview
10.8 TV
10.8.1 Connection of standard TV sets
Functions Order No.
IR TV control module universal
Interface for control of a standard TV set using infrared signals.
Applicable in connection with RAN inter-face (77 0840 00)
Consisting of a control module and an in-frared transmitting unit. Mounting directly to the infrared input of the TV set.
For configuration of the control signals the TV model must be known.
Dimensions (HxWxD): 40 x 100 x 50 mm
70 0360 10
IR TV control module universal Audio
Interface for control of a standard TV set using infrared signals.
Integrated audio amplifier for driving an oper-ator device. The output volume can be adjusted within predefined limits using a pro-gramming tool. The audio levels have to be adapted to the patient handset.
Applicable in connection with RAN inter-face (77 0840 00)
Consisting of a control module and an in-frared transmitting unit. Mounting directly to the infrared input of the TV set.
For configuration of the control signals the TV model must be known.
Dimensions (HxWxD): 40 x 120 x 65 mm
70 0360 11
Kit for IR TV control module
Connection and mounting kit for IR TV control module universal.
70 0360 20
108 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.8.2 Hospital LCD TV
Kit for IR TV control module audio
Connection and mounting kit for IR TV control module universal audio.
70 0360 21
Addressing plug for IR TV control moduleUse with IR TV control module universal and universal audio. Addressing for assignment of the patient handsets for controlling the TV set.
One plug needed per project.
70 0360 30
TV control module programming
Service for one-time programming of the con-trol codes to the IR TV control module univer-sal or IR TV control module universal audio.
One-time needed per TV set model in use.
70 0360 50
Functions Order No.
Hospital LCD TV 26”, professional
LCD TV for use in patient rooms. Prepared for use together with Flamenco nurse call system.
Screen diagonal: 66 cm / 26 inch
Image format: 16:9
VESA standard
Design and version in compliance with cur-rent standard equipment. Further details on request.
XX* in the order no. stands for the current year, e.g. 74 7005 26/13 for 2013.
74 7005 26/XX*
Image similar
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 109
10. Product overview
Hospital LCD TV 32”, professional
LCD TV for use in patient rooms. Prepared for use together with Flamenco nurse call system.
Screen diagonal: 81 cm / 32 inch
Image format: 16:9
VESA standard
Design and version in compliance with cur-rent standard equipment. Further details on request.
XX* in the order no. stands for the current year, e.g. 74 7005 32/13 for 2013.
74 7005 32/XX*
Image similar
Hospital LCD TV 42”, professional
LCD TV for use in patient rooms. Prepared for use together with Flamenco nurse call system.
Screen diagonal: 107 cm / 42 inch
Image format: 16:9
VESA standard
Design and version in compliance with cur-rent standard equipment. Further details on request.
XX* in the order no. stands for the current year, e.g. 74 7005 32/13 for 2013.
74 7005 32/XX*
Image similar
TV installation kit
for Hospital LCD TV, professional.
XX* in the order no. stands for the current year, e.g. 74 7002 56/13 for 2013.
74 7002 56/XX*
TV wall mount „Base“
One pivot point
Tilting, pivoting
VESA MIS-D, 100, MIS-D, 75
Additional adapter for VESA MIS-E 200 x 200mm
74 7002 80
Functions Order No.
110 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
TV wall mount „Advance“
Two pivot points
Tilting, pivoting and extendible
VESA MIS-D, 100, MIS-D, 75
Additional rails for VESA MIS-E 200 x 200mm
74 7002 81
TV wall mount „Comfort“
Three pivot points
Tilting, pivoting and extendible
VESA MIS-D, 100, MIS-D, 75
Additional rails for VESA MIS-E 200 x 200mm
74 7002 82
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 111
10. Product overview
10.9 Supplementary system components
Functions Order No.
Loudspeaker with announcement interface
Big, high efficiency, ceiling-mounted loud-speaker. For mounting in hallways and large rooms.
Adjustable amplifier for announcements
Transducer for entertainment transmis-sion
Connection to OSYlink-Announcement
Weight: 1,25 kgDiameter: approx. 267 mmHeight: approx. 135 mmCut-out in ceiling: 238 mm
05 0024 01
Door entry speaker
For voice communication between main door and nurse call system. Suitable for use at out-side and inside doors.
2 integrated buttons: Call and Delete
3 status lamps
Microphone and loudspeaker
Surface mounting
Installation in furniture possible
Direct connection to OSYlink-Door entry speaker
Control of door lock release
IP 53
Ambient temperature (operation): -25 – +55 °CDimensions (HxWxD): 215 x 100 x 36 mm
77 0350 00
112 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.10 Interfaces
10.10.1 Interfaces in the group
Functions Order No.
OSYlink-Door entry speaker
Interface for connecting a door entry speaker (77 0350 00) to the group bus (OSYnet).
2-wire-connection to the door entry speaker (data and speech)
Connection for door opener transformer 12 V AC
Mounting on wall or top-hat rail (35 mm), several units can be mounted side-by-side
Outputs short-circuit and overload pro-tected
Input for local call cancelling in combina-tion with a separate switch
Dimensions (HxWxD): 90 x 106 x 58 mm
77 0801 00
OSYlink-Group lamp
Interface for connecting group lamps to the group bus (OSYnet). Usable as collective or direction display. Room allocation and group forming possible.
4 x 2 potential-free outputs for connecting 4 group lamps, with two light sections each
Power supply selectable (jumper) internal from the nurse call system or external
Display compliant with DIN VDE 0834:2000, centrally configurable
Flexible allocation of user addresses in the software SystemOrganizer
Mounting on wall or top-hat rail (35 mm), several units can be mounted side-by-side
Outputs short-circuit and overload pro-tected
Dimensions (HxWxD): 90 x 106 x 58 mm
77 0802 00
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 113
10. Product overview
OSYlink-Universal
Interface for connecting of external systems and/or technical devices to the group bus (OSYnet).
4 monitored Inputs: 2x Call, Emergency call, Cardiac alarm
1 Input, Collective announcement to all wards
1 Input, Collective announcement to all staff
1 Input for raising a call, associated an in-put for cancelling this call.
4 configurable solid state outputs. Default: 2x Call, Emergency call, Cardiac alarm
1 configurable solid state output
1 configurable solid state output with loca-tion light feature (functionally associated with the inputs for calls)
2 configurable potential-free outputs (change-over contact, voltage source can be selected by jumper)
The outputs are configured using the Sys-temOrganizer.
Mounting on wall or top-hat rail (35 mm), several units can be mounted side-by-side
Outputs short-circuit and overload pro-tected
Dimensions (HxWxD): 90 x 160 x 58 mm
77 0803 00
OSYlink-Announcement
Interface for connecting announcement loud-speakers with announcement interface (05 0024 01) to the group bus (OSYnet). Connection of single devices or groups.
Audio output for driving active loudspeak-ers (max. 5 loudspeakers)
1 potential-free digital output for control of signalling the activity of the announce-ment system
Mounting on wall or top-hat rail (35 mm), several units can be mounted side-by-side
Outputs short-circuit and overload pro-tected
Dimensions (HxWxD): 90 x 106 x 58 mm
77 0804 00
Functions Order No.
114 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
OSYlink AS-CCS
Interface for the compatible connection of a ward using one of the following legacy sys-tems to the Flamenco system: EccoLine with speech, NewLine C201, NewLine, CCS 2000 G, CCS 1080 G, CCS 1080 W.
The interface transforms the data and speech signals of the legacy system into compatible signals for the Flamenco system. This way, it is possible to run individual wards using a legacy system in a Flamenco system environ-ment.
For connecting a half-duplex speech system CCS1080 W additionally a speech amplifier (74 8000 00) with the power supply unit (21 8000 00) is required.
Configuration with SystemOrganizer
24 V-power supply from the ward power supply unit
Mounting on wall or top-hat rail (35 mm), several units can be mounted side-by-side
Dimensions (HxWxD): 90 x 160 x 58 mm
77 0870 00
OSYlink AS-L200
Interface for the compatible connection of a ward using one of the following legacy sys-tems to the Flamenco system: EccoLine L200, NewLine L200.
The interface transforms the data signals of the legacy system into compatible signals for the Flamenco system. This way, it is possible to run individual wards using a legacy system in a Flamenco system environment.
Configuration with SystemOrganizer
24 V-power supply from the ward power supply unit
Mounting on wall or top-hat rail (35 mm), several units can be mounted side-by-side
Dimensions (HxWxD): 90 x 160 x 58 mm
77 0872 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 115
10. Product overview
10.10.2 Interfaces in the room
Functions Order No.
RAN interface
Interface for the connection of a third-party device to the room bus (RAN).
A top-hat rail clip is included with delivery.
Available applications:
External call device raises call type „Call“.
External call device raises call type „Car-diac alarm“.
External call device raises call type „WC call“.
External presence sensor switches pres-ence 1 or 2.
External devices serves as privacy button.
Telephone call raises call type „Tele-phone call“.
TV set is controlled using patient handset.
Dimensions (HxWxD) without top-hat rail clip: 32 x 34 x 16 mm
77 0840 00
RAN interface with speech
Interface for the connection of analogue speech systems per bed to the room bus (RAN). As patient units telephones or other devices with speech can be used, provided that they comply with the specification for the connection. The patient unit to be used has to be approved by Tunstall GmbH.
Mounting on a top-hat rail e.g. in a medical supply unit.
Dimensions (HxWxD) without fixing clips: 13 x 51 x 95 mm
77 0880 00
116 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
RAN interface universal
Interface for the connection of 2 external actuators being controlled by the patient handset universal (74 0748 00), e.g. blinds upwards / blinds downwards. Transferring the signals in combination with a connection socket combi universal (70 0449 00) or a connection socket combi, bedhead unit, uni-versal (70 0448 00).
2 potential-free normally open contacts
Maximum contact load: 60 mA / 24 V.
Control by one or all patient handsets uni-versal in the room
Connection to the room bus (RAN).
Intended for mounting on a 35 mm sup
Dimensions (HxWxD): 76 x 72 x 41 mm
70 0848 00
Telephone interface relay
for connecting analogues telephones to a nurse call system. A telephone call will be displayed as a call in the nurse call system.
Mounting on a 35 mm top-hat rail.
Dimensions (HxWxD): 70 x 35 x 70 mm
11 5350 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 117
10. Product overview
10.11 System control
Functions Order No.
OSY-ControlCenter
Control centre for the nurse call system, mon-itors and controls all communications between the various system components. It also serves as the central interface for the input and output of data, speech connections and system messages. It allows for the cen-tral system access for servicing the system and for later expansions via remote access.
The OSY-ControlCenter is a self-sufficient system unit and it is independent of supple-mentary external equipment such as net-works and LAN components. Even if faults occur at systems or components which are connected via interfaces or networks, the basic function of the nurse call system will be sustained. This functional security is valid for the whole system and it is not limited to spe-cific ward-related functions.
The modular setup allows for the adaptation to different sizes of systems. Several OSY-ControlCenters may be coupled.The number of modules required for a particular project or installation depends on the total number of users to be linked to the system and on the number of internal and external communica-tion connections to be provided for. Additional interfaces can be added to the system at any time, for instance for HIS, facility manage-ment and linking of PBX.
Designed as 19” wall cabinet, also suita-ble for mounting in commercially available 19-inch racks (8HU)
External network switch, 1 height unit (other dimensions acc. to relevant equip-ment)
Ample room for connecting the installa-tion, separate protective cover and fixing possibility for incoming cables
For easy mounting and to facilitate trou-ble-shooting, all connections are plug-in type connectors
Integrated system monitoring with display of system status via allocated LEDs, visi-ble from outside
Supply voltage: 24 V DC
118 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
OSY-ControlCenter Master-2
Maximum number of connections:
2 groups
220 users
77 2002 00
OSY-ControlCenter Master-4
Maximum number of connections:
4 groups
440 users
77 2004 00
OSY-ControlCenter Master-6
Maximum number of connections:
6 groups
660 users
77 2006 00
OSY-ControlCenter Master-8
Maximum number of connections:
8 groups
880 users
77 2008 00
OSY-ControlCenter Slave-2
Requires a master. Maximum number of connections:
2 groups
220 users
77 2202 00
OSY-ControlCenter Slave-4
Requires a master. Maximum number of connections:
4 groups
440 users
77 2204 00
OSY-ControlCenter Slave-6
Requires a master. Maximum number of connections:
6 groups
660 users
77 2206 00
OSY-ControlCenter Slave-8
Requires a master. Maximum number of connections:
8 groups
880 users
77 2208 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 119
10. Product overview
OSYnet-SafetyController
SafetyController for direct connection to the group bus (OSYnet). In case of OSY-Control-Center fail, the SafetyController will automati-cally take over the control of the group bus. In safety operating mode, all basic functions of the nurse call system will be sustained.
Control of the nurse call system's basic functions for a physical group in accord-ance with DIN VDE 0834:2000.
Automatic switching between normal and safety operating mode
1 potential-free switching contact (change-over contact) for indication of op-erating mode
1 potential-free switching contact (change-over contact) for indication of faults
Dimensions (HxWxD): 90 x 106 x 58 mm
77 2100 00
120 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.12 Power supply
Functions Order No.
Power supply unit UPS
Power supply unit for supplying the nurse call system with safety extra-low voltage (SELV), compliant with EN 60950-1. The number of rooms, that can be connected, is project spe-cific. Integrated batteries for uninterruptible operation with a minimum of 15 minutes backup power supply.
Wide range input for international use.
Short-circuit and overload protected.
Control LEDs and contact outputs for trans-mission of status information: normal opera-tion, battery operation, fault message.
Closed housing in protection class I. Designed for wall mounting in rooms
Weight: 9 kgDimensions (HxWxD): 244 x 325 x 178 mm
77 3400 00
Power supply unit UPS 60
Power supply unit for supplying the nurse call system with safety extra-low voltage (SELV), compliant with EN 60950-1. The number of rooms, that can be connected, is project spe-cific. Uninterruptible operation in connection with battery set for UPS 60 (77 3450 00), with approx. 1 hour backup power supply.
Wide range input for international use.
Short-circuit and overload protected.
Control LEDs and contact outputs for trans-mission of status information: normal opera-tion, battery operation, fault message.
Closed housing in protection class I. Designed for wall mounting in rooms, prefera-bly above the battery set for UPS 60.
Weight: 4 kgDimensions (HxWxD): 244 x 325 x 178 mm
77 3400 10
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 121
10. Product overview
Battery set for UPS 60
Batteries which build in connection with the power supply unit UPS 60 an uninterruptible power supply (UPS) with approx. 1 hour backup power supply.
Closed housing in protection class III. Designed for wall mounting in rooms, prefera-bly below the power supply unit UPS 60.
Weight: 2 kgDimensions (HxWxD): 244 x 325 x 178 mm
77 3450 00
Power supply unit
Power supply unit for supplying the nurse call system with safety extra-low voltage (SELV), compliant with EN 60950-1. The number of rooms, that can be connected, is project spe-cific.
Wide range input for international use.
Short-circuit and overload protected.
Control LEDs and contact outputs for trans-mission of the active operation status.
Closed housing in protection class I. Designed for wall mounting in rooms
Weight: 2 kgDimensions (HxWxD): 244 x 325 x 178 mm
77 3401 00
Functions Order No.
122 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
10.13 Installation
Functions Order No.
OSYnet-Y-RepeaterOpto
Data repeater for electric isolation of the group bus (OSYnet).
Designed for separating and/or isolating the group bus into two independent sections. Y-distribution.
Application: One for each physical group.
Direct connection to group bus (OSYnet) and its sections (Sub-D, 9-pole).
Top-hat mounting 35 mm
Dimensions (HxWxD): 85 x 25 x 83 mm
77 4000 00
OSYnet-Gateway
Active gateway for electric isolation of group bus OSYnet. Designed to extend the max. cable length for the OSYnet by 700 m.
Direct connection to the group bus (OSYnet) and its sections, screw clamps
Electric isolation of line sections
Top-hat mounting 35 mm
Dimensions (HxWxD): 105 x 37 x 35 mm
77 4001 00
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 123
10. Product overview
10.14 Accessories
Functions Order No.
Steel loudspeaker frame
for loudspeaker with announcement inter-face (05 0024 01).
Weight: 570 g
Fire protection rating to B2 (DIN 4102)
Diameter of installation cut-out: 238 mmInstallation depth: 215 mm
00 0272 48
USB connection cable
e.g. for connecting a printer to a PC.
Plug A / plug B
Length: 1-5 m
00 0647 74
Line transformer (100/25 V, 10 W)
to transform the entertainment voltages from 100 V eff to 25 V eff. Preferably installed as a level transformer. One transformer is required per entertainment channel. Suitable to be integrated into distributor units. Potential sep-aration.
Input voltage: 100 V eff
Output voltage: 25 V eff
Max. output power: 10 W
Frequency response: 50 Hz - 10 kHz
Weight: 930 g
Dimensions (HxWxD): 93 x 58 x 65 mm
14 1000 00
Back box solid wall, 1-gang
Mounting opening: Ø 60 mmDepth: 46 mmE.g. for signal lamps, switches, connection socket with call switch.
17 0100 00
124 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Back box solid wall, 2-gang
Mounting opening: 140 x 60 x 42 mm, ovalWithout separating.E.g. for connection socket combi, connection socket ComStation.
17 0410 00
Back box partition wall, 1-gang
Burr hole: Ø 68 mmDepth: 47 mmE.g. for signal lamps, switches, connection socket with call switch.
17 5100 00
Back box partition wall, 2-gang
Burr hole: Ø 2 x 68 mm, oval
Depth: 47 mm,Centre distance: 71 mm, without separating
E.g. for connection socket combi, connection socket ComStation.
17 5400 00
Security transformer (24 V/250 VA)
for wall mounting for external supply of addi-tional signal lamps
Nominal power approx. 250 VA
Input voltage 230 V, 50/60 Hz
Output voltage 24 V +/- 5% selectable/switch-able
Weight: 5,0 kg
Dimensions (HxWxD): 240 x 175 x 130 mm
21 1200 00
Equipment and cable clamp
Practical protection for all patient units. Cables and equipment are safely guided along the bed supporting rod or the ”bed gal-lows”. The clamp will come off when the pull-ing force it too high.
Packing unit = 10 clamps.
70 0361 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 125
10. Product overview
Patient handset bracket
Wear-free plastic bracket with integrated ele-ment to change the volume with the unit parked at the bracket. Vertical or horizontal mounting.
Dimensions (HxWxD): 198 x 57 x 18 mm
70 0800 00
Patient handset bed bracket Völker
Wear-free plastic bracket with integrated ele-ment to change the volume with the unit parked at the bracket. For use with a bed from Völker company.
Dimensions (HxWxD): 198 x 100 x 60 mm
70 0800 10
Headphone
Headphone with 3.5 mm jack plug to listen discretely to entertainment/TV programmes in connection with the patient handsets.
1.8 m connection cable
70 0801 00
Self-releasing adapter, patient unit
Automatic release for excessive pulling force. Separates the line connection between patient handset and connection socket, thereby preventing any physical damage
13-pole connector
Dimensions (HxWxD): 17 x 17 x 120 mm
74 0812 50
Self-releasing adapter, pear push switch
as 74 0812 50, but for pear push switch.
8-pole connector
Dimensions (HxWxD): 14 x 14 x 120 mm
74 0812 51
Functions Order No.
126 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
Connector, 3-pole
Plug-type connecting clamp for connecting of switches and room lamps to the room bus (RAN).
Screw connections up to 1.5 mm²
70 0807 00
Connector, 4-pole
Plug-type connecting clamp for connecting the connection socket with call switch to the room bus (RAN).
Screw connections up to 1.5 mm²
70 0807 01
Connector, 7-pole
Plug-type connection clamp for connecting the room lamps universal.
Screw connections up to 1.5 mm²
70 0807 07
LED module, red
for room lamps.
Signalling of calls
77 0190 00
LED module, yellow
for room lamps.
Signalling of staff presence 2
77 0190 01
LED module, green
for room lamps.
Signalling of staff presence 1
77 0190 02
LED module, white
for room lamps.
Signalling of WC calls
77 0190 03
LED module, blue
for room lamps.
Signalling of alarms
77 0190 04
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 127
10. Product overview
Smoke detector
Opto-electronic smoke detector including pluggable relay module for connecting to the Tunstall nurse call system.
77 0901 00
IP-NTP TimeServer DCF77
The TimeServer receives time signals using DCF77 signals. It is a stand alone version and transfers the time signals via the Ether-net using the SNTP protocol.
When used in the Flamenco system and con-nected to the OSY-ControlCenter the system time will be updated automatically.
Mounting on top-hat rail
Power supply 24 VDC
Active DCF 77 antenna
Configuration software for Microsoft Win-dows
77 0910 00
IP-NTP TimeServer GPS
The TimeServer receives time signals using GPS signals. It is a stand alone version and transfers the time signals via the Ethernet using the SNTP protocol.
When used in the Flamenco system and con-nected to the OSY-ControlCenter the system time will be updated automatically.
Mounting on top-hat rail
Power supply 24 VDC
GPS antenna
Configuration software for Microsoft Win-dows
77 0910 01
OSYnet-Connecting plug
for OSYnet-Y-RepeaterOpto.
77 0950 00
Functions Order No.
128 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
10. Product overview
ControlTerminal ConfigSet
Configuration tool for configuring the Con-trolTerminal Flamenco and the ControlTermi-nal with doorplate Flamenco.
USB/OSYnet-Interface
All required connection cables and plugs
Wall power supply unit for the ControlTer-minal to be configured
Configuration software
Online help
77 0920 00
ControlTerminal installation kit
for mounting a Control Terminal to a standard two gang back box.
Mounting plate
4-pole connector, up to 2.5 mm²
2 insertion bridges
8-pole connectors
Fixing screws
Pre-mounted.
77 0960 00
Functions Order No.
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 129
10. Product overview
130 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
11. Index
11. Index
Numerics1 Channel bracelet transmitter 931 Channel hand held transmitter 931 Channel radio receiver 26, 92
AAccessories 124Acknowledge 19Address 38Addressing plug for IR TV control module 57,109Addressing plug for IR TV control module uni-versal 56Alarm 7, 9, 11, 12, 13, 16, 17, 24, 27Alarm button 7, 18, 78, 82, 83, 97, 98Announcement 22, 83, 95, 96, 99Answered call 7, 12Answering forwarded calls 17Area announcement 22, 38Arrow 12, 75Automatic answering 95AWG 43
BBack box partition wall, 1-gang 125Back box partition wall, 2-gang 125Back box solid wall, 1-gang 124Back box solid wall, 2-gang 125Back boxes 68Bath tub 62Bath tube 61Battery set for UPS 60 122Bed 49, 51, 53, 96, 99Blinds upwards/downwards 87, 88Blue button 18, 78, 82, 83, 97, 98Blue light section 11BMA 39Bus termination 43
CCable legend 71Cable length 43Cable types 43Call 9, 11, 12, 13, 16, 21, 27
Accept 19Acknowledge 19Call category 11, 13, 16, 17, 24Call type 9Cancel 19Raise 18Remote cancelling 19
Call button 9, 10, 11, 18, 77, 80, 81, 82, 83, 85,90, 91, 97, 98Call category 9, 11, 13
Call 12Call escalation 10Call forwarding 7, 10, 20, 32, 33, 35, 80, 81Call forwarding point 15, 17, 19Call handling 15, 18, 95Call handling consoles 95Call location 16, 19, 24, 96, 99Call recording 96, 100, 101Call switch 4, 49, 51, 53, 61, 62, 68, 77Call switch with privacy switch 21, 68, 81Call switch/WC 49, 51, 53, 68Call switch/WC with cancel switch 68, 80Call tone 13, 16, 17, 20, 24Call type 9, 20, 24Calls at the same time 12, 13, 16Calls witch/WC 77Cancel 19Cancel button 11, 19, 20, 78, 80Cancel switch/WC 4, 20, 49, 68, 78Cardiac alarm 9, 12, 18
Cancel 20Cardiac alarm switch 68, 78Care data 100Care management 37CAT 43CCS 28, 115Central call handling 34Central console 15, 17, 19, 22, 34Channel encoding 59Children’s room 21ComStation 12, 15, 19, 22, 32, 33, 35ComStation/BUS-C 4, 12, 15, 21, 42, 63, 88,95ComStation/CT Flamenco 16, 21, 42, 64, 88,97ComStation/PC 12, 21, 42, 65, 89, 95ComStation/T Flamenco 19, 66ComTerminal 4, 15, 17, 19, 20, 21, 22, 59ComTerminal Flamenco 7, 17, 18, 42, 49, 60,61, 69, 82Configuration 37, 38Connection socket 26Connection socket combi 49, 54, 56, 58, 69, 86Connection socket combi Universal 55, 69, 87Connection socket combi, bedhead unit 49, 54,56, 58, 69, 87Connection socket combi, bedhead unit Uni-versal 55, 69, 88Connection socket combi, bedhead unit, TVL
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 131
11. Index
57, 69, 88Connection socket combi, TVL 57, 69, 86Connection socket ComStation 63, 64, 66, 69,88Connection socket ComStation/PC 69, 89Connection socket with call switch 51, 53, 68,85Connection socket with call switch, bedheadunit 51, 53, 68Connection sockets 85Connector, 3-pole 127Connector, 4-pole 127Connector, 7-pole 127Connectors 68Console 8, 9, 10, 15, 19, 21, 33Consoles 95Control unit 41ControlTerminal 50ControlTerminal ConfigSet 51, 62, 129ControlTerminal Flamenco 24, 51, 62, 69, 84ControlTerminal Installation kit 51ControlTerminal installation kit 62, 129ControlTerminal with doorplate Flamenco 51,62, 69, 84Corner seating unit 49, 51, 53Corridor display 4, 13, 22Corridor display Alpha 16 13, 67, 76Corridor display Alpha 16, double-sided 67, 76Country-specific settings 38
DDecentralised mode 34DECT 29DECT telephone 10Diagnostic call 9
Cancel 20Diagnostic connection cable 93Dimming 87, 88DIN VDE 0834 3, 9
Fail safety 45Direction lamp 12, 13, 67, 69, 75Disconnection call 9Doctor 7, 9Door call 9, 19
Cancel 19Door entry speaker 9, 112Doorplate Universal 75
EEar phones 90EccoLine 28, 115Emergency call 7, 11, 12, 13, 16, 17, 18, 24,27Emergency call 1 9Emergency call 2 9
Cancel 20Entertainment 26, 86, 87, 88Equipment and cable clamp 125
FFacility Management-System 30Failure of the electric power supply 45Fault location 46Fire detection system 29, 104Flashing 12, 13, 17Flickering 12Forwarded call 20Fresh call 7, 12Function room 34, 60Functional nursing 32
GGeneral announcement 23General cables 71Green button 7, 8, 77, 81, 82, 83, 97, 98Green light section 11, 12, 13, 24Grey button 19, 20, 78, 80, 81Group 43, 44Group bus 3, 27, 40, 71Group lamp 12, 13, 67Group lamp, 2 groups 69, 76Group lamp, 3 groups 69, 76Group lamp, 4 groups 69, 76
HHandset 21Handsfree speech 21Headphone 126HIS 29HL7 29Hospital information system 29Hospital LCD TV 109Hospital LCD TV 26“, professional 109Hospital LCD TV 32“, professional 110Hospital LCD TV 42“, professional 110
IInfrared 56, 57Infusomat 9Interface 25, 38, 40
At group bus 27At the central control 29In rooms 26In the group 113
Interfaces 113In the room 116
IP-NTP TimeServer DCF77 128IP-NTP TimeServer GPS 128IR TV control module universal 26, 56, 108IR TV control module universal Audio 57, 108
132 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
11. Index
KKIS 39Kit for IR TV control module 56, 108Kit for IR TV control module Audio 57, 109
LLaser printer b/w 106LED modules 127Legacy system 27, 115Light 54
Dimming 55Light button 90, 91Light section 11, 12, 13
Flashing 12Flickering 12
Light switching 26Line transformer (100/25 V, 10 W) 124Location light 11Loudspeaker with announcement interface 22,67, 112
MManagementCenter 3, 15, 17, 19, 22, 34ManagementCenter/PC 17, 21, 42, 99ManagementCenter/PC Push buttons 100Medical monitoring device 9Medical supply unit 68Mobile console 15, 16, 19Monitor 17” 107Monitor 19” 107Multiple line 22
NNewLine 28, 115Non-system speech paths 42Nurse station 10, 32Nurse station without speech 66Nursing documentation 101Nursing staff 7, 9, 18
OOpenConcept 25Organisation 31, 44Organisational entity 44OSY-CC DIA Interface 104OSY-CC FDS Interface 104OSY-CC VoIP-SIP Interface 16, 103OSY-ControlCenter 29, 37, 40, 41, 44, 118OSY-ControlCenter Master-4 119OSY-ControlCenter Master-6 119OSY-ControlCenter Master-8 119OSY-ControlCenter Slave-2 119OSY-ControlCenter Slave-4 119OSY-ControlCenter Slave-6 119
OSY-ControlCenter Slave-8 119OSYlink AS 27OSYlink AS-CCS 28, 115OSYlink AS-L200 28, 115OSYlink-Announcement 114OSYlink-Door entry speaker 67, 113OSYlink-Group lamp 67, 113OSYlink-Universal 27, 67, 114OSYnet 3, 27, 40, 71
Cable types 71Maximum permissible cable lengths 43
OSYnet-Connecting plug 128OSYnet-Gateway 43, 123OSYnet-SafetyController 39, 45, 120OSYnet-Y-RepeaterOpto 43, 70, 123
PPartial system failure 45Patient 9, 18Patient device
Third-party device 21Patient handset 4, 18, 22, 26, 42, 49, 54, 56,57, 90
TV control 56Patient handset bed bracket Völker 126Patient handset bracket 126Patient handset Universal 55, 91Patient room 7, 34, 48
Light dimming 55Light switching 54Separate shower and WC 59TV control 57, 58
Patient room with speech 48Patient room without speech 50, 52Patient units 90Patient’s telephone 42Pear push switch 18, 26, 85, 86, 87, 88Pear push switch incl. 2 call switches, 2 m con-nection cable 51, 53, 92Pear push switch incl. 2 call switches, 4 m con-nection cable 51, 53, 92Pear push switch incl. call and light switch 54Pear push switch incl. call and light switch, 2 mconnection cable 51, 53, 91Pear push switch incl. call and light switch, 4 mconnection cable 51, 53, 91Personal 10Physical entity 44Planning office 37Planview 38, 65Plug 9Pneumatic activation 18Pneumatic call switch 4, 18, 61, 62, 68, 80Pneumatic call switch/WC 49, 51, 53, 68Power supply 45, 121Power supply unit 4, 40, 46, 122
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 133
11. Index
Power supply unit UPS 121Power supply unit UPS 60 121Presence 7, 8, 11, 13, 16, 17, 18, 20, 21Presence 1 7, 8, 9, 11, 12, 16, 17, 24Presence 2 7, 8, 9, 11, 12, 16, 24Presence button 7, 11, 77, 81, 82, 83, 97, 98
Staff 1 8Staff 2 8
Presence message 7PrimusGlobal+ "Call recording" 101PrimusGlobal+ “Project data up to 36 rooms,layout” 105PrimusGlobal+ “Project data up to 36 rooms,standard” 105PrimusGlobal+ „System set-up and configura-tion“ 105PrimusGlobal+ module “Connect” 30, 102PrimusGlobal+ Project data up to 36 rooms 65PrimusGlobal+ System driver CUS 102PrimusGlobal+ System driver FDS 102PrimusGlobal+ System driver FMS 102PrimusGlobal+ System driver HL7 102PrimusGlobal+ System set-up & configuration65Priority 9, 16Privacy 7, 21Privacy button 21, 22, 81Privacy function 22Project 37PSA 39Pull cord 18Pull cord call switch 4, 18, 61, 62, 68, 79Pull cord call switch/WC 49, 51, 53, 68Pulse relay 54Push buttons 17
RRadio 26Radio call devices 26Radio paging system 29, 39RAN 3, 12, 40, 82, 83, 97, 98RAN interface 57, 58, 116RAN interface Universal 91, 117RAN interface with speech 26, 116Reading light 26, 54Reanimation team 9Reassurance light 11Red button 18, 77, 80, 81, 82, 83, 85, 90, 91,97, 98Red call button 18Red light section 11, 13, 24Relay for light switching 54Reminder light 8, 11Remote cancelling 19, 20Room bus 3, 12, 40, 83, 97, 98
Room button 82Room lamp 4, 9, 11, 12, 24, 49, 53, 84Room lamp cardiac alarm, WC 49, 53, 70, 73Room lamp cardiac alarm, WC, glass decor 70,74Room lamp Universal 12Room lamp Universal, 2 sections 63, 65, 70,75Room lamp Universal, 2 sections, glass decor70, 75Room lamp, 3 sections 49, 53, 61, 64, 70, 73Room lamp, 3 sections, glass decor 70, 73Room lamp, 3 sections, with doorplate 70, 73Room lamp, 4 sections 70, 74Room lamp, 4 sections, glass decor 70, 74Room lamp, 4 sections, with doorplate 70, 74Room light 26, 54Room number 38Room terminals 82Room types 47Rooms without speech communication 24RoomTerminal 52RoomTerminal Flamenco 7, 18, 19, 24, 53, 69,83Rufklasse 11Ruftaste 11
SSecurity transformer (24 V/250 VA) 125Self releasing adapter, patient unit 126Self releasing adapter, pear push switch 126Sensor mat for connection socket 94Several calls 12, 13, 16Shift 35, 95Signal lamps 73Signalling 11
In the room 11Smoke detector 128Software administration contract 96, 100, 101Sound detector 92Speech 19Speech amplifier 115Speech cable 71Speech communication 3, 15, 21, 42Speech connection 19, 20Speech devices 21Speech per bed 21Speech per room 21Staff 7, 9, 15, 18Staff announcement 22Staff presence combination with call tone 7, 20,51, 62, 68, 81Staff presence switch 7, 68Staff room 9Station 43
134 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
11. Index
Steady light 13Steel loudspeaker frame 124Supplementary system components 112Switches 77Switching relay 55System computer 99, 100, 106System control 118System overview 39System planning 38System safety 45System structure 40, 41SystemOrganizer 3, 10, 12, 13, 14, 17, 21, 22,24, 33, 37, 106
Requirements 37Software training 37
TTeam 35Technology 39Telephone call 9, 75
Cancel 20Telephone interface relay 117Telephony 4, 29, 38Ticker 13Time 14, 38TV 26, 56, 57, 86, 87, 88, 90, 108TV control module programming 109TV control module programming service 56, 57TV installation kit 58, 110TV wall mount “Advance” 111TV wall mount “Base” 110TV wall mount “Comfort” 111
UUSB connection cable 124
VVESA 58, 110
WWard 32, 33, 40, 44Ward announcement 22Ward bathroom 61Ward bathroom with speech 61Ward bathroom without speech 62Ward console 15, 19, 22, 32, 35, 63, 64, 65Ward console ComStation/PC 65Ward coupling 12, 38, 96Ward mode 96Ward operating mode 32Ward planview 16WC 9, 12, 49, 51WC call 7, 9, 11, 12, 18, 24
Cancel 19, 20WC emergency call 7, 9, 11, 12, 18, 24
White light section 11, 12, 24Wireless telephone 15, 16, 19, 21, 42
YYellow button 7, 8, 77, 82, 83, 90, 91, 97, 98Yellow light section 11, 24
ZZone 35
Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0) 135
11. Index
136 Flamenco - System Description - 00 8812 64, 12/13 (Rev. 3.0)
TunstaOrkott48291Germat: +49 f: +49 (info@t
www.t
6386
Find all you want to know about the Flamenco nurse call system:
Flamenco Data Sheet Catalogue
FlaOrd
FlaOrd
Fla
The dowww.
ll GmbHen 66 Telgteny(0) 25 04/7 01-00) 25 04/7 01-4 99unstall.de
unstall.de
QUALITYMANAGEMENT
SYSTEM
DQS certified toDIN EN ISO 9001
Reg. no. 56386
Reg. no. 5
menco System Descriptioner No. 00 8812 64
menco Technical Manualer No. 00 8812 60
menco Instructions for Use
cuments are ready for downloading:tunstall.de