fleet modernization upgrade jan 2019–isaac gonzález sevillano · 4. dcs implementation dcs...
TRANSCRIPT
![Page 1: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/1.jpg)
www.tecnatom.es All right reserved ® 2017
1
Jan 2019 – Isaac González Sevillano
Fleet Modernization Upgrade
![Page 2: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/2.jpg)
www.tecnatom.es All right reserved ® 2017
2
index
Introduction
Computers and Simulation Environment Modernization
Input/output System Modernization
Codes/models Modernization
DCS Modernization
Conclusions, Lessons learned & operating experience
Fleet Modernization Upgrade
![Page 3: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/3.jpg)
www.tecnatom.es All right reserved ® 2017
3
Introduction
![Page 4: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/4.jpg)
COMPANYFOUNDATION
ZORITA NPPPROGRAM STARTS
TECHNOLOGICALINDEPENDENCEACHIEVED
TECNATOM AS INTERNATIONALGROUP
www.tecnatom.es Corporate PresentationAll rights reserved
DEVELOPMENT OF SPANISH NPPPROGRAM
195719571957 196219621962 70’s70’s70’s 80’s80’s80’s 2010’s2010’s2010’s
1975-1979
Automated Inspection Systems
Full Scope Simulators
90’s
Internationalization inNuclear Markets
Consolidation of Strategic Alliances
2000’s
Diversification to Synergic Markets
Company Milestones
![Page 5: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/5.jpg)
Subsidiaries & Shared Companies
Representatives
Projects
International Footprint
www.tecnatom.es
![Page 6: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/6.jpg)
Current Nuclear Fleet
New Reactors
Advanced Reactors
Research Reactors
Gas Combined
Coal
Cogeneration
Renewable
Oil & Gas
Manufacturing
Process Industry
Aerospace
Railway
Automotive
Power
Generation
Industrial
www.tecnatom.esCorporate Presentation
All rights reserved
Markets1
Life
cycle
Complex technological industries with thehighest quality and safety standards
![Page 7: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/7.jpg)
7
www.tecnatom.es
Value propositionDevelop and implement integrated and innovative solutions that promote the safety, efficiency and reliability of your assets, processes and the performance of people
2 3 4
Training&
Safety
Inspection&
Testing
Technology&
Product
Digital Operation& Asset Mgmt
1
Corporate PresentationAll rights reserved
![Page 8: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/8.jpg)
www.tecnatom.es All right reserved ® 2017
8 Fleet Modernization Upgrade
• 5 Spanish replicasimulators.
• Certified accordingto the ANSI-3.5
Introduction
![Page 9: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/9.jpg)
www.tecnatom.es All right reserved ® 2017
9 Fleet Modernization Upgrade
All Spanish FSS had a specificmodernization plan.
• First Stage: Long-Term operation.- Modernization of Computers and
simulation environment- Modernization of Input/output System
• Second Stage: Improve OperatorTraining.
- Improve new codes/models to trainnew scenarios (shutdown sequences,severe accident...)
- Implementation of DCS
Introduction
![Page 10: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/10.jpg)
www.tecnatom.es All right reserved ® 2017
10
Computers and Simulation Environment Modernization
![Page 11: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/11.jpg)
www.tecnatom.es All right reserved ® 2017
11 Fleet Modernization Upgrade
Computers and Simulation Environment Modernization
Avoid obsolescence of SimulatorArchitecture:
• New computers, from Unix toWindows
• New Simulation environment
• Porting of the source code (newcompilation).
![Page 12: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/12.jpg)
www.tecnatom.es All right reserved ® 2017
12
Input/output System Modernization
![Page 13: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/13.jpg)
www.tecnatom.es All right reserved ® 2017
13 Fleet Modernization Upgrade
Input/output System Modernization
Avoid obsolesce of I/O System (hard tofind spare cards)
Tesis+ is the evolutionary design of theTesis I/O system.
It is a distributed system based on aTCP/IP network protocol (fast or GIGA-Ethernet) running under Windows OS(64 bits) with a client/server architecture.
![Page 14: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/14.jpg)
www.tecnatom.es All right reserved ® 2017
14
Codes/models Modernization
![Page 15: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/15.jpg)
www.tecnatom.es All right reserved ® 2017
15 Fleet Modernization Upgrade
Codes/models Modernization
• Migration to the Tecnatom model buildermodels (Team Suite: Team_Flow,Team_Logic, Team_Electric…)
• Upgrade thermal hydraulics codes tocope with new scenarios: midloop, openvessel…
• Add new codes to cope with SevereAccident Scenarios. MAAP
![Page 16: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/16.jpg)
www.tecnatom.es All right reserved ® 2017
16 Fleet Modernization Upgrade
Codes/models Modernization: Shutdown Scenarios
• Best Estimated codes (TRAC_RT) upgradedto cope with incondensable gas, allowingcontinuous operation in outage scenarios.
• Highly demanded by training schools andthe regulatory body
• Scenarios to train based on PSA and plantoperational experiences
• More relevant midloop operations and open-vessel
![Page 17: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/17.jpg)
www.tecnatom.es All right reserved ® 2017
17
DCS Modernization
![Page 18: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/18.jpg)
www.tecnatom.es All right reserved ® 2017
18 Fleet Modernization Upgrade
DCS Modernization
• New DCS of Spanish NPPs such as newturbine digital control systems, new feed watercontrol systems, etc… have beenimplemented in FSS in the recent years.
• They are based on platforms such as OvationMARKVI, S7,etc…
• Implementation first in Simulators lead tonumerous benefits. Most important:
- Tune the DCS in Simulator- Operator Training in advance
![Page 19: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/19.jpg)
www.tecnatom.es All right reserved ® 2017
19 Fleet Modernization Upgrade
DCS Implementation. Feed Water Level Control of Cofrentes NPP
• Replace the analog control system,panel components and humanmachine interfaces. Under MARKVIplatform of GE
• The DCS implementation pursued 4goals:
1. Control response analysis and tuning2. Plant operators training in advance3. Operating and Functional Procedures
review and validation4. HFE: Validation and Regulatory Body
requirements fulfillment
![Page 20: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/20.jpg)
www.tecnatom.es All right reserved ® 2017
20
CONCLUSIONSLessons learned & operating experience
![Page 21: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/21.jpg)
www.tecnatom.es All right reserved ® 2017
21 Fleet Modernization Upgrade
CONCLUSIONS
Benefits of the modernization process in the Spanish FSS:
• Extension of the simulators life
• Simulators stability and robustness
• Improved training in new scenarios
• The implementation in the simulator of the DCS prior than in plant, lead to these benefits:
- Detection of discrepancies and parameters adjustment- Training the operators in advance- Simulator behaviour closer to real plant- Physical Fidelity- Review of procedures- Validation of the HMI
![Page 22: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/22.jpg)
www.tecnatom.es All right reserved ® 2017
22 Fleet Modernization Upgrade
Lessons learned & operating experience
1. Planification of Simulators Modernization� Avoid obsolesce and ensure long-term operation.
the sooner the better
2. Source code porting� Different results with different compilers
� Long time of testing: Whole simulator to be tested
3. Shutdown sequences� Long time scenarios: make the training sessions
dynamic and prioritized according to PSA
4. DCS implementation� DCS usually required of high level of detail
models
60
62
64
66
68
70
72
74
76
78
0 500 1000 1500 2000
T34 = 5.2 min
T34 = 2.6 min
T34 = 10 min
generic control
wcap-9284
generic control (2)
60
62
64
66
68
70
72
74
76
78
0 500 1000 1500 2000
T34 = 5.2 min
T34 = 2.6 min
T34 = 10 min
generic control
wcap-9284
generic control (2)
![Page 23: Fleet Modernization Upgrade Jan 2019–Isaac González Sevillano · 4. DCS implementation DCS usually required of high level of detail models 60 62 66 68 70 72 74 76 78 0 500 1000](https://reader033.vdocument.in/reader033/viewer/2022053012/5f0f2ed27e708231d442e5d2/html5/thumbnails/23.jpg)
“©2017 Tecnatom, S.A.
Todos los derechos reservados. El contenido de esta obra está protegido por la Ley y no podrá ser
reproducida, ni en todo ni en parte, ni transmitida, ni registrada por ningún sistema de
recuperación de información, en ninguna forma ni por ningún medio, sin el consentimiento previo
y por escrito de Tecnatom, S.A. y de sus autores.
Tecnatom y el logotipo de Tecnatom son marcas registradas de Tecnatom, S.A.”
www.tecnatom.es
“©2017 Tecnatom, S.A.
Todos los derechos reservados. El contenido de esta obra está protegido por la Ley y no podrá ser
reproducida, ni en todo ni en parte, ni transmitida, ni registrada por ningún sistema de
recuperación de información, en ninguna forma ni por ningún medio, sin el consentimiento previo
y por escrito de Tecnatom, S.A. y de sus autores.
Tecnatom y el logotipo de Tecnatom son marcas registradas de Tecnatom, S.A.”
www.tecnatom.es