45,000 - 60,000 BTU/hr. FLOOR FURNACES WILLIAMS These models offer affordable solutions for limited- space floor plans, remodels and remote cabin locations. Williams’ Floor Furnaces use no above-the-floor room space and efficiently circulate warm air by natural convection, without the aid of a blower. Our models are fitted with an automatic floor register grille temperature control. FEATURES No electricity required. “Matchless” pilot igniter Easy Installation Natural and propane models (conversion kits available) Combustion chamber lifts out for easy service Long-life and quiet heavy-duty burner Automatic temperature and safety controls Resettable vent-limit safety switch Not approved for use in Canada.

Upload: others

Post on 04-Oct-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

45,000 - 60,000 BTU/hr.

FLOOR FURNACES

WILLIAMS™

These models offer affordable solutions for limited-space floor plans, remodels and remote cabin locations. Williams’ Floor Furnaces use no above-the-floor room space and efficiently circulate warm air by natural convection, without the aid of a blower.

Our models are fitted with an automatic floor register grille temperature control.

FEATURES• No electricity required.• “Matchless” pilot igniter• Easy Installation• Natural and propane models (conversion kits available)

• Combustion chamber lifts out for easy service• Long-life and quiet heavy-duty burner• Automatic temperature and safety controls• Resettable vent-limit safety switch

Not approved for use in Canada.

FLOOR FURNACES

4505622A 4505621A 45,000 31,000 70 58.0 24 32 28 ½ 24 ¼ 32 ⅜ MILLIVOLT 147

6005622A 6005621A 60,000 42,000 70 58.0 24 42 28 ½ 24 ¼ 42 ⅜ MILLIVOLT 174

BTU/hr. INPUT

BTU/hr. OUTPUT WITHD

SHIPPING WEIGHT

(LBS.)PROPANENATURAL

MODEL NUMBER

AFUETHERMAL

EFFICIENCY PERCENT

LENGTHWIDTH

DIMENSIONS (INCHES)

HEIGHT

WILLIAMS™

“MATCHLESS” PILOT IGNITER All models include a “matchless” pilot igniter that assures convenient pilot lighting without matches.

FLOOR REGISTER TEMPERATURE CONTROL Williams' Floor Furnaces are equipped with an automatic floor register grille temperature control. This meets the latest American National Standards Institute Requirements. In extreme weather conditions, this control may be overridden to allow increased heat output

INTERIOR FURNACE CLEARANCES 6ʺ between the floor furnace and adjacent wall. 12ʺ between the floor furnace and doors, draperies or other combustible materials. 15ʺ walking space along two sides of the furnace.

Elevation rating from sea level to 2,000' Consult Owner’s Manual for installation of product at elevations over 2000' 1/2ʺ Gas Connection

EASY INSTALLATION

250 W. Laurel Street · Colton, CA 92324 USA Subject to change without notice © 2021 Williams L1026, 4-21

WARNING: This product can expose you to chemicals including epichlorohydrin which is known to the State of California to cause cancer and birth defects and/or other reproductive harm. For more information go to www.p65warnings.ca.gov

FEATURES

LENGTH

FLOOR OPEINING (IN.)THERMOSTAT

FLOOR

FLOOR JOIST

THIS SPACE MUST BE THE SAME SIZE AS THE OPENING CUT IN THE FLOOR

NOTE: THE HEADERS MUST NOT BE A SMALLER SIZE LUMBER THAN THE JOISTS

FURNACE

HEADERS

NOTE: IF TWO JOISTS ARE CUT, USE A DOUBLE

HEADER

450A 8953 8955

600A 8954 8956

MODEL SERIES

NATURAL TO

PROPANE

PROPANE TO

NATURAL

JOIST HEADERS

DEPTH OF THE FURNACE

18ʺ MINIMUM WORKING SPACE

FURNACE

12ʺ MINIMUM

12ʺ MINIMUM ON ALL SIDES EXCEPT CONTROL END OF THE FURNACE

DRAIN FROM FURNACE PIT

GROUND LEVEL12ʺ

4ʺ VENT PIPE (¼ʺ RISE PER FOOT)

VENTILATION OPENING

FIRST FLOOR

WALL

4ʺ VENT PIPE

18ʺ MINIMUM ON THE CONTROL END OF

THE FURNACE

CONVERSION KITS

THERMOSTAT SOLD SEPARATELY part number P322016

ANY WARRANTY CONSIDERATIONS ARE CONTINGENT ON INSTALLATION BY A QUALIFIED INSTALLER (CONTRACTOR). SELF-INSTALLATION IS PROHIBITED AND WILL INVALIDATE YOUR WARRANTY. • Read owner’s manual before using/installing.• Photographs are representative only.• Check local codes and ordinances for permitted uses.• Consult installation manual for clearances prior to installation.• We reserve the right to amend product specifications without notice.• Installation and servicing recommended by a qualified service person.• Please read the warranty for any limitations of disclaimers. Combustion chamber carries a 10-year limited warranty. All other parts carry a one-year limited warranty.• Venting must comply with the “Venting and Chimney Requirements” section of the instruction manual.• Massachusetts Approval G3-0816-23.