floor standing series · 2019. 3. 11. · rhr-1214-b r22 r410a non inverter floor standing series...

6
RHR-1214-B R22 R410A Non Inverter Floor Standing Series R410A FVGN-0319-F

Upload: others

Post on 18-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • RHR-1214-B

    R22

    R410ANon Inverter

    FloorStanding

    Series

    R410A

    FVGN-0319-F

  • Indoor ModelType Outdoor Model CapacityRange (Btu/hr)

    Floor Standing Product Line Up

    TYPE

    OF

    REF

    RIG

    ERA

    NT

    • FVN30/40/50/60AV1L

    • FVGR08/10NV1

    • FVPGR10/13/15/18/20NY1

    RN28/30CV1

    28,000-29,000

    36,000-55,000

    80,000-100,000

    100,000-200,000

    RN35/40/50/61DY1

    RUR08/10NY1

    RUR13/15/18/20NY1

    R41

    0A

    DIR

    ECT

    AIR

    BLO

    WD

    UC

    T C

    ON

    NEC

    TIO

    N

    RUR10NY1

  • ● Prominent temperature display● Real-time clock display● Easily accessible buttons

    White display lights up to indicate modes and temperature settings when activated

    KEY LOCK icon is displayed when activated to prevent children or others from tampering with the control buttons on the units

    Activation and deactivation of keylock by pressing ‘SWING’ and ‘TURBO’ simultaneously for 5 seconds

    Modern And Stylish DesignDaikin floor standing series is designed with stylish profile and classy control panel which could blend in any interior environment.

    Aesthetic Black Control Panel The control panel comes with large button for ease operation. It provides a white LED light for clear display when activated.

    Wireless Remote ControllerDaikin floor standing unit is incorporated with IR sensor for usage with wireles controller.

    DGS01wireless controller

    OFF State ON State

    Space saving with style and functionality* Applicable to model FVN30AV1L-60AV1L only

    Prod

    uct F

    eatu

    res

    Far Air ThrowThe floor standing is able to achieve air throw distance up to 25m*.* Note: Based on model FVN60AV1L

  • Removable Washable Saranet FilterRemoval of airborne dust particles through saranet filter ensures cleaner air supply.

    Turbo ModeThis function is available in COOL and DRY modes. Upon activation, the unit will run at full power with the indoor fan running at high speed for 20 minutes. This will provide a fast cooling for immediate comfort.

    Advanced Ion Plasma Technology For Air PurificationIon plasma generator remove airborne contaminates from the air we breathe, and thus create a refreshing environment .

    Generator

    Safety cache for prevention of access to electrical and mechanical parts during removal of filter.

    Auto Random RestartIn the event of sudden power failure during operation, the system will automatically restart-ed from the last setting condition. This eliminates the need to restart manually after each power failure.

  • Easy OperationDigital Remote Control Comes Standard With Indoor UnitTemperature setting is possible by button operation. The set temperature is conveniently displayed on the LED.

    50m maximum length and 30m maximum level difference to cover medium and large-scale building needs.

    Note 1 : It cannot be used for FVGR08-10NV1, FVPGR10-20NY1Note 2 : It cannot be used for FVPGR10-20NY1

    Prod

    uct F

    eatu

    res

    Design FlexibilityDesigned For Long Refrigerant Piping

    Enhanced Varieties Of Factory ModificationAnd Optional Accessories

    1

    2

    3

    4

    5

    6

    7

    8

    9

    Note 1

    Note 1 Note 2

    3

    1

    2

    4

    89

    6

    7

    5

    On/Off button LED display

    Compressor operation lamp.

    Fan operation lamp.

    Cool operation lamp.

    Fan button

    Temp. setting up

    Temp. setting down

    Mode button

    Outdoor unit roof installation possible for plenty of leeway.

    Max. length

    Max. level difference

    DirectAir Blow

    Auto restartModify for central control adapter kit (DAT107A55)Change fan motor and pulleyDischarge grill plenum chamberSide discharge grillon discharge plenum chamberLower drain panFront suction high efficiency filter chamber

    Fresh air inletRear suctionDrain pumpRemote sensor (Thermistor for suction air)All fresh air application

    LCD remote controller2Intelligent touch controller2Central remote controller2Unified ON/OFF controller2Schedule timer3Remote sensor (thermostor for suction air)3Remote controller

    Central control adaptor kit(external terminal for ON/OFF, abnormal)1

    Standard modelFactory modificationContact sales formore information

    DTA107A55

    BRC1C62DCS601C51

    DCS302CA61DCS301B61DST301BA61

    KRCS01-1-

    Low outdoor temp. 15˚C application and long pipe70m application

    Front suction base flange for front suction highefficiency filter chamberSuction grill for front suction high efficiencyfilter chamber

    DuctConnection

    Type

    Floor Standing Type

    Fact

    ory

    Mod

    ifica

    tion

    Opt

    ion

    -

    --

    -

    -

    Note: 1Wiring modification is needed on floor stand model to connect with central control ADP kit. 2Need to use central control adapter kit for option connection. 3Central control adapter kit and LCD remote controller is necessary for option connection.

    To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.

    DurabilityHeat Exchange Fins Provided With Anti-Corrosion Treatment

    Flexible design and great liability for factory and offices* Applicable to model FVGR08NV1-10NV1, FVPGR10NY1-20NY1 only

  • SpecificationFVN30AV1L FVN40AV1L FVN50AV1L FVN60AV1L

    RN30CV1

    FVN40AV1L

    RN35DV1 RN40DY1 RN50DY1 RN61DY1

    Btu/hr 29,000 42,000 45,000 55,000

    W 8,500 12,309 13,189 16,120

    W 2,900 4,100 4,900 5,490

    A 13.40 [6.58] [8.42] [9.35]

    Btu/hr / W 10.00

    FVN30AV1L

    RN28CV1

    28,000

    8,208

    2,840

    13.0

    9.86

    36,000

    10,550

    3,860

    17.10

    9.33

    71

    10.24 9.18 10.02

    V/Ph / Hz 220-240 / 1 / 50

    l/s / CFM

    Pa/in.wg

    319 / 675 489 / 1,035 489 / 1,035 552 / 1,170

    dBA 44 49 50 54

    UNIT DIMENSION INDOOR UNIT 1,850 x 600 x 270

    (H x W x D) OUTDOOR UNIT 753 x 855 x 328

    INDOOR UNIT 42 45 48 51

    OUTDOOR UNIT 57 95 84 105

    LIQUID mm/in

    GAS mm/in 19.05 / 3/4

    RUNNING CURRENT, 1ø[3ø]

    MODELINDOOR UNIT

    OUTDOOR UNIT

    TOTAL COOLING CAPACITY

    INPUT POWER

    COPPER PIPE SIZE

    EER

    POWER SOURCE

    REFRIGERANT TYPE R410A

    -

    AIR FLOW

    EXTERNAL STATIC PRESSURE

    SOUND PRESSURE LEVEL(MEASURED IN SOUND ROOM)

    mm

    UNIT WEIGHT kg

    DIRECT BLOW (AUTOMATIC LOUVER LEFT & RIGHT)AIR DISCHARGE

    380-415 / 3 / 50

    1,850 x 600 x 350

    HEAT INSULATION BOTH LIQUID AND GAS PIPING

    852 x 1,030 x 400

    9.52 / 3/8

    15.88 / 5/8

    1. DUE TO PRODUCT INNOVATION, ALL SPPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE2. ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARD ISO 5151 3. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4. SOUND PRESSURE LEVELS ARE MEASURED IN ANECHOIC CHAMBER. DURING ACTUAL OPERATION, SOUND PRESSURE LEVEL WILL HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.5. THE RUNNING CURRENT MEASURED AT SITE MAY VARY FROM THE SPECIFICATIONS STATED

    FVN30AV1L-60AV1L

    1. DUE TO PRODUCT INNOVATION, ALL SPPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE2. ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARD ISO 5151 3. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4. SOUND PRESSURE LEVELS ARE MEASURED IN ANECHOIC CHAMBER. DURING ACTUAL OPERATION, SOUND PRESSURE LEVEL WILL HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.5. THE RUNNING CURRENT MEASURED AT SITE MAY VARY FROM THE SPECIFICATIONS STATED

    FVGR08NV1-10NV1 , FVPGR10NY1-20NY1FVGR08NV1 FVGR10NV1 FVPGR13NY1 FVPGR15NY1 FVPGR18NY1 FVPGR20NY1

    RUR08NY1 RUR10NY1

    FVPGR10NY1

    RUR10NY1 RUR13NY1 RUR15NY1 RUR18NY1 RUR20NY1

    Btu/hr 80,000 100,000 120,000 160,000 180,000 200,000

    W 23,447 29,308 35,170 46,893 52,755 58,617

    W 10,000 11,200 14,900 17,800 21,200 24,800

    A [16.8] [18.9] [24.3] [29.0] [34.6] [40.4]

    Btu/hr / W 8.00 8.93

    100,000

    29,308

    11,400

    [19.2]

    8.77 8.05 8.99 8.49 8.06

    V/Ph / Hz

    l/s / CFM 902 / 1,910 1,336 / 2,830

    -

    dBA 60 61

    UNIT DIMENSION INDOOR UNIT 1,870 x 950 x 510 1,870 x 1,170 x 510 1,740 x 1,170 x 510

    (H x W x D) OUTDOOR UNIT

    INDOOR UNIT 107 143

    OUTDOOR UNIT 203 206

    150

    206 243 319 322 329

    LIQUID mm/in

    GAS mm/in 22.23 / 7/8

    MODELINDOOR UNIT

    OUTDOOR UNIT

    TOTAL COOLING CAPACITY

    INPUT POWER

    SOUND PRESSURE LEVEL(MEASURED IN SOUND ROOM)

    mm

    UNIT WEIGHT kg

    RUNNING CURRENT, 1ø[3ø]

    EER

    POWER SOURCE

    REFRIGERANT TYPE

    COPPER PIPE SIZE

    AIR DISCHARGE

    380-415 / 3 / 50

    R410A

    DIRECT BLOW DUCT CONNECTION

    2,001 / 4,240

    147 / 0.59

    1,336 / 2,830 2,700 / 5,720

    62 63

    1,870 x 1,470 x 720

    AIR FLOW

    12.7 / 1/2 15.88 / 5/8

    28.58 / 1-1/8 34.93 / 1-3/8

    1,870 x 1,170 x 720

    1,680 x 930 x 765 1,680 x 1,240 x 765

    180 240

    Pa/in.wgEXTERNAL STATIC PRESSURE

    BOTH LIQUID AND GAS PIPINGHEAT INSULATION