flow blurring catalogue

13

Upload: ingeniatrics-tecnologias

Post on 07-Dec-2014

527 views

Category:

Technology


6 download

DESCRIPTION

- Low energy consumption - Cost efficient, very competitive price for high quantities - Simple geometry, Robust performance and low maintenance - Scalable: easily adjustable to your capacity needs, scaling out and/or up - Size range for different viscosities: Through small changes in operational conditions you obtain different size ranges with no need to change your Flow Blurring® nebulizer - Versatility

TRANSCRIPT

Page 1: Flow Blurring Catalogue
Page 2: Flow Blurring Catalogue

FlowInn FB Nebulizers

FWFB240T – Diameter 240 µm (tube)

FWFB240C – Diameter 240 µm (connector)

FWFB500T – Diameter 500 µm (tube)

FWFB500C – Diameter 500 µm (connector)

Applications:

Laboratory, coating,

localized nebulization or administration

Flow rates:

240 µm: 0,01 to 0,5 ml/min.

500 µm 0,1 to 10 ml/min.

FWFB240 FWFB500

Page 3: Flow Blurring Catalogue

Masterflow FB-Nebulizer

MFFB240T – Diameter 240 µm (tube)

MFFB240C – Diameter 240 µm (connector)

MFFB500T – Diameter 500 µm (tube)

MFFB500C – Diameter 500 µm (connector)

Applications: Laboratory, coating,

localized dispersion

Flow rates: 240 µm: 0,01 to 0,5 ml/min.

500 µm 0,1 to 10 ml/min.

High chemical resistance

MFFB240T MFFB240C

Page 4: Flow Blurring Catalogue

FB-Lab Nebulizers

PSFB240 – Diameter 240 µm

PSFB500 – Diameter 500 µm

Applications:

Spray Drying or Spray Chilling (liquid-gas)

and Emulsions (liquid-liquid) lab equipment.

Flow rates:

240 µm: 0,01 to 0,5 ml/min.

500 µm 0,1 to 10 ml/min.

High chemical resistance

Page 5: Flow Blurring Catalogue

EC-flow FB Nebulizers

ECFB0700 – 90º Diameter 700 µm

ECFB0700 – 180º Diameter 700 µm

ECFB1200 – 90º Diameter 1200 µm

ECFB1200 – 180º Diameter 1200 µm

ECFB1800 – 90º Diameter 1800 µm

ECFB1800 – 180º Diameter 1800 µm

Applications:

Coating, Water treatment, Lixiviates treatment, Wastes

treatment, Biomaterials production, Suspensions drying,…

Tailored with your brand ECFB0700 180º

ECFB0700 90º

Page 6: Flow Blurring Catalogue

NE4 FB Nebulizers

N4FB200 – Diameter 2 mm

N4FB400 – Diameter 4 mm

N4FB600 – Diameter 6 mm

Applications:

Spray Drying, Spray Chilling

Fluid Bed, Coating, Wastes treatment,

Biomaterials production, Water Treatment, …

Standard model: length 15cm

(available in different lengths)

Page 7: Flow Blurring Catalogue

®

7

Dye in polystyrene,

5 µm, CV 69%

(PSFB240S)

Shellac,

0.5-7 µm

(PSFB500S)

Maltodextrin,

0.3-4 µm

(PSFB500S)

Page 8: Flow Blurring Catalogue

8

Nanoclays suspension (15 %),

x50: 7 µm NE-4 N4FB6000 50 l/h

Lixiviate treatment,

X50: 19.7 µm ECFB1200 90º

NE4 inside

Spray Dryer

tank

Page 9: Flow Blurring Catalogue

cutting-edge technology to produce a spray of extremely

fine droplets within a desired range when monodispersion

is not strictly required

Consists in the micro-mixing of fluids using a

reflux cell

Pneumatic atomization with the highest

efficiency, up to 200 times more energy-

saving

Page 10: Flow Blurring Catalogue

Easily adjustable droplet size, up to tens of nm

Low energy consumption

Cost efficient, very competitive price for high quantities

Simple geometry, Robust performance and low maintenance

Scalable: easily adjustable to your capacity needs, scaling out and/or up

Versatility – Compatible with any liquids,

suspensions, polymeric solutionsand emulsions

– Verified for the following material:

Dissolutions:

Alginate, Quitosan, Shellac, Maltodextrine, …

Suspensions :

Clay, Lixiviates, Brine, …

Others

Fragrances and Perfumes, Urea, Oils,…

Glycerin, Creams, Paraffin

– Qualified for high concentrations and high viscosity:

• 0,9 up to 145.000cP

10

Page 11: Flow Blurring Catalogue

11

Viscosity Size range x50

1 cP from 3 to 53 microns

550 cP from 9 to 30 microns

3500 cP from 8 to 85 microns

13000 cP from 12 to 93 microns

53000 cP from 18 to 30 microns

145000 cP from 35 to 55 microns

Through small changes in operational conditions you obtain different

size ranges with no need to change your Flow Blurring® nebulizer

Page 12: Flow Blurring Catalogue

12

MODEL PART NUMBER TECHNOLOGY USE

Ø NOZZLE

EXIT HOLE

CALIBER

(µm)

Ø CAPILAR

(µm)

Ø AIR

FLOW

RANGE

(ml/min)

CONECTING

POSITION

Ø SIZE

RANGE

(µm)

FWFB240T FWNEB001000 Flow-Blurring Laboratory 240 240 0,01-0,5 3-30

FWFB240C FWNEB002000 Flow-Blurring Laboratory 240 240 0,01-0,5 3-30

FWFB500T FWNEB003000 Flow-Blurring Laboratory 500 500 0,1-10 3-30

FWFB500C FWNEB004000 Flow-Blurring Laboratory 500 500 0,1-10 3-30

MFFB240T MFNEB001000 Flow-Blurring Laboratory 240 240 0,01-0,5 3-30

MFFB240C MFNEB002000 Flow-Blurring Laboratory 240 240 0,01-0,5 3-30

MFFB500T MFNEB003000 Flow-Blurring Laboratory 500 500 0,1-10 3-30

MFFB500C MFNEB004000 Flow-Blurring Laboratory 500 500 0,1-10 3-30

PSFB240S PSNEB001000 Flow-Blurring Spray Dryer 240 240 0,01-0,5 3-30

PSFB500S PSNEB002000 Flow-Blurring Spray Dryer 500 500 0,1-10 3-30

ECFB0700 ECNEB001000 Flow-Blurring Industrial 700 700 5-35 90º 7-53

ECFB0700 ECNEB002000 Flow-Blurring Industrial 700 700 5-35 180º 7-53

ECFB1200 ECNEB003000 Flow-Blurring Industrial 1200 1200 8-80 90º 7-53

ECFB1200 ECNEB004000 Flow-Blurring Industrial 1200 1200 8-80 180º 7-53

ECFB1800 ECNEB005000 Flow-Blurring Industrial 1800 1800 10-160 90º 7-53

ECFB1800 ECNEB006000 Flow-Blurring Industrial 1800 1800 10-160 180º 7-53

N4FB2000 N4NEB001000 Flow-Blurring Industrial 2000 2000 10-160 7-35

N4FB4000 N4NEB002000 Flow-Blurring Industrial 4000 4000 80-425 7-53

N4FB6000 N4NEB003000 Flow-Blurring Industrial 6000 6000 160-850 7-35

Page 13: Flow Blurring Catalogue

Our technological service offer Development & Production of high value microspheres based on our proprietary technology for Microencapsulation:

Study and evaluation of starting material.

Design of innovative solutions for the required application based on our technology.

Pre-formulation studies and technology fitting.

Microparticle characterization : morphology, composition, analytical methods, etc.

Initial studies: stability, drug delivery profiles…

Scale-up and microparticle production.PI Parque Plata. C/Camino Mozárabe, 4141900 Camas, Sevilla. España/Spain

T. (+34)954 081 214 F. (+34)955 98022513