flp-pmc-012 + pmce-012 - public address system · model power requirement power consumption output...

25
The PMC 012 12-Zone Remote Paging Microphone is designed to work hand- in-glove with Zone Selector (FLP-ZS-9812MKII) to build a platform of unified applications for emergency notification and remote paging. To maximize utilization, both built-in chime and override notification can be found in this paging console. The PMCE 012 12-Zone Paging Console Extension Unit is an extension to extend the broadcasting zones up to 12, 36 or 48 zones. Together with PMC 012, each unit of PMCE 012 allows extension of 12 different speaker zones. Each unit of PMCE 012 works with one unit of ZS 9812MKII to realize the zone selection function. FLP-PMC-012 + PMCE-012 12-channel Paging Console • Condenser gooseneck microphone adorned with illuminated ring • Two RJ45 port for 12-zone triggering • One XLR-balanced microphone output with volume control and LED display • One 2-tone chime generator with volume control • ALL CALL line out which link to extension unit PMCE 012 as well • 12-zone switches control with LED indicator • DC 24V interface Product Features Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish Specifications PMC 012 24V DC 2W ±775mV 600ohm, balanced >60dB 160 Hz ~ 12 kHz 180 x 150 x 52mm 1.2kg Black PMCE 012 24V DC 1W - - - 140 x 145 x 52mm 0.8kg Black Portable Sound System Mixer Amp/ Pre Amp/ Power Amp Paging Microphone & Zone selector Rack mount equipment DC 24V input Connect to Pre-Amplifier Connect to ZS-9812MKII 16

Upload: others

Post on 19-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

The PMC 012 12-Zone Remote Paging Microphone is designed to work hand- in-glove with Zone Selector

(FLP-ZS-9812MKII) to build a platform of unified applications for emergency notification and remote paging.

To maximize utilization, both built-in chime and override notification can be found in this paging console.

The PMCE 012 12-Zone Paging Console Extension Unit is an extension to extend the broadcasting zones up

to 12, 36 or 48 zones. Together with PMC 012, each unit of PMCE 012 allows extension of 12 different speaker zones.

Each unit of PMCE 012 works with one unit of ZS 9812MKII to realize the zone selection function.

FLP-PMC-012 + PMCE-01212-channel Paging Console

• Condenser gooseneck microphone adorned with illuminated ring

• Two RJ45 port for 12-zone triggering

• One XLR-balanced microphone output with volume control and LED display

• One 2-tone chime generator with volume control

• ALL CALL line out which link to extension unit PMCE 012 as well

• 12-zone switches control with LED indicator

• DC 24V interface

Product Features

Model

Power Requirement

Power Consumption

Output Level

S/N Ratio

Frequency Response

Dimension (D x W x H)

Weight

Material & Finish

Specifications

PMC 012

24V DC

2W

±775mV 600ohm, balanced

>60dB

160 Hz ~ 12 kHz

180 x 150 x 52mm

1.2kg

Black

PMCE 012

24V DC

1W

-

-

-

140 x 145 x 52mm

0.8kg

Black

Po

rtable

Sou

nd

System

Mixe

r Am

p/ P

re A

mp

/ Po

we

r Am

pP

agin

g M

icro

ph

on

e

& Z

on

e se

lec

tor

Rac

k mo

un

t eq

uip

me

nt

DC 24V input

Connect toPre-Amplifier

Connect toZS-9812MKII

16

Page 2: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

Please follow the instructions in this manual to obtain the optimum results from this unit.We also recommend that you keep this manual handy for future reference.

OP

ER

AT

ION

MA

NU

AL

PUBLIC ADDRESS SYSTEM

12 ZONES REMOTE PAGING MICROPHONEFLP-PMC012

FLP-PMC01212 ZONES REMOTE PAGINGMICROPHONE

TMTM

OUTPUT LEVEL

-18 -15 -12 -9 -6 -3 0 +3 +6 +9

-18 -15 -12 -9 -6 -3 0 +3 +6 +9

CH8

CH7

CH6

CH5

CH12

CH11

CH10

CH9

CH4

CH3

CH2

CH1

CHIME ALL TALK

POWER

Page 3: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

TABLE OF CONTENTS

2FLP-PMC012

1. SAFETY PRECAUTIONS .......................................................................................3

2. FEATURES ...............................................................................................................5

3. NOMENCLATURE AND FUNCTIONS

3.1 Front Panel ............................................................................................................. 6

3.2 Rear Panel..............................................................................................................7

4. .............................................................................................................8

5. APPLICATIONS .......................................................................................................9

6.SPECIFICATIONS .................................................................................................. 10

7.DIMENSIONAL DIAGRAM ....................................................................................11

OPERATION

Page 4: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference.

Safety Symbol and Message ConventionsSafety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety

Indicates a potentially hazardous situation which, if mishandled, couldresult in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, couldresult in moderate or minor personal injury, and/or property damage.

When Installing the Unit

Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.

Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.

Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock.

Be sure to replace the unit's terminal cover after connection completion. Because high voltage is applied to the speaker terminals, never touch these terminals to avoid electric shock.

Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe as a catastrophic disaster may result.

Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling down, causing personal injury and/or property damage.

When the Unit is in Use

Should the following irregularity be found during use, immediately switch off the power, disconnect the power supply plug from the AC outlet and contact your nearest dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock. If you detect smoke or a strange smell coming from the unit. If water or any metallic object gets into the unit If the unit falls, or the unit case breaks If the power supply cord is damaged (exposure of the core, disconnection, etc.) If it is malfunctioning (no tone sounds.)

To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to your nearest dealer.

Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock.

Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock.

3

1. SAFETY PRECAUTIONS

FLP-PMC012

Page 5: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated inthe electrical installation of the building.

When Installing the Unit

Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock.

When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.

When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull.

Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and result in fire.

Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock.

When the Unit is in Use

Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage.

Make sure that the volume control is set to minimum position before power is switched on. Loud noise produced at high volume when power is switched on can impair hearing.

Do not operate the unit for an extended period of time with the sound distorting. This is an indication of a malfunction, which in turn can cause heat to generate and result in a fire.

Contact your dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result.

If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely.

Switch off the power, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more. Doing otherwise may cause a fire or electric shock.

1. SAFETY PRECAUTIONS

4FLP-PMC012

Page 6: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

5

2. FEATURES

FLP-PMC012

1. 1 MIC input

2. Built-in bell output

3. Output level instruction

4.12 Division trigger (with the FLP-ZS9812MKII on-line use)

5. DC 24V interface

Page 7: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

FLP-PMC01212 ZONES REMOTE PAGINGMICROPHONE

MIC

1122

33

PUSH

OUTPUT LEVEL

-18 -15 -12 -9 -6 -3 0 +3 +6 +9

-18 -15 -12 -9 -6 -3 0 +3 +6 +9

CH8CH7CH6CH5

CH12CH11CH10CH9

CH4CH3CH2CH1

CHIME ALL TALKPOWER

6

3. NOMENCLATURE AND FUNCTIONS

3.1 FRONT PANEL

FLP-PMC012

1 2 3 4

6

5

4. ALL

All zones button

5. TALK TALK button

6. CH1~CH12 zones button

7. CH1~CH12 zones indicator

1. OUTPUT LEVEL

2. POWER

Power indicator

. CHIME

Chime button

Signal indicator

3

7

Page 8: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

POWER

CHIMEVOL

MICVOL

MIN MAXMIN MAX

COM1 COM2ZONE1~6 ZONE7~12

MIX OUT

ALL OUT OUT IN

NOMENCLATURE AND FUCTIONS

7

3.2 REAR PANEL

FLP-PMC012

1. POWER SWITCH

2. ALL OUT

Short-circuit the signal

region output

3. OUT

OUTPUT DC 24V

4. IN

Input DC 24V

8761 3

5. COM1/COM2

Network Communication

Interface(Zone 1~12)

6. MIX OUT

MIC volume and CHIME volume output(XLR)

7. MIC VOL

MIC volume control

8. CHIME VOL

Chime volume control

2 4 5

POWER 24V 2A

Page 9: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

8FLP-PMC012

4. OPERATION

5.3.XLR CONNECTIONS

Page 10: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

5. APPLICATIONS

REAR PANEL CONNECTIONS

9 FLP-PMC012

POWER

CHIMEVOL

MICVOL

MIN MAXMIN MAX

COM1 COM2ZONE1~6 ZONE7~12

MIX OUT

ALL OUT OUT IN

DC24V+ -

RELAY TRIG

RELAY CON T

REMOTE SELECT

PIN 1-Z1PIN 2-Z2PIN 3-Z3PIN 4-Z4PIN 5-Z5PIN 6-Z6PIN 7-ACPIN 8-PR

AMP 1AMP 1

10

0V

10

0V

CO

MC

OM

ZONE 1ZONE 1

10

0V

10

0V

CO

MC

OM

AMP 2AMP 2

10

0V

10

0V

CO

MC

OM

ZONE 2ZONE 2

10

0V

10

0V

CO

MC

OM

AMP 3AMP 3

10

0V

10

0V

CO

MC

OM

ZONE 3ZONE 31

00

V1

00

V

CO

MC

OM

AMP 4AMP 4

10

0V

10

0V

CO

MC

OM

ZONE 4ZONE 4

10

0V

10

0V

CO

MC

OM

AMP 5AMP 5

10

0V

10

0V

CO

MC

OM

ZONE 5ZONE 5

10

0V

10

0V

CO

MC

OM

AMP 6AMP 6

10

0V

10

0V

CO

MC

OM

ZONE 6ZONE 6

10

0V

10

0V

CO

MC

OM

AMP 9AMP 9

10

0V

10

0V

CO

MC

OM

ZONE 9ZONE 9

10

0V

10

0V

CO

MC

OM

AMP10AMP10

10

0V

10

0V

CO

MC

OM

ZONE10ZONE10

10

0V

10

0V

CO

MC

OM

AMP 7AMP 7

10

0V

10

0V

CO

MC

OM

ZONE 7ZONE 7

10

0V

10

0V

CO

MC

OM

AMP 8AMP 8

10

0V

10

0V

CO

MC

OM

ZONE 8ZONE 8

10

0V

10

0V

CO

MC

OM

AMP11AMP11

10

0V

10

0V

CO

MC

OM

ZONE11ZONE11

10

0V

10

0V

CO

MC

OM

AMP12AMP12

10

0V

10

0V

CO

MC

OM

ZONE12ZONE12

10

0V

10

0V

CO

MC

OMREMOTE SELECT

PIN 1-Z7PIN 2-Z8PIN 3-Z9PIN 4-Z10PIN 5-Z11PIN 6-Z12PIN 7-ACPIN 8-GND

AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 1 TO 6 AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 7 TO 12

FLP-ZS9812MKII

100V 70V 4~16 COM

OUTPUT

LINKLINK

GND

LIFT

~230V/50Hz ~230V/50Hz

FUSE

POWER POWER FUSE FUSE

T10AL 250VT10AL 250V

T8AL 250VT8AL 250V

T6.3AL 250VT6.3AL 250V350W350W

500W500W

650W650W

INPUTSINPUTS

1122

33

RISK OF ELECTRIC SHOCKDO NOT OPEN

RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIRAVIS:

PUBLIC ADDRESS SYSTEM

SERIAL NO:

AMPLIFIER

Short-circuit the signal region output

POWER 24V 2A

Page 11: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

6.SPECIFICATIONS

MODEL

OUTPUT

FREQUENCY RESPONSE

CROSSTALK

DIMENSION(mm)

WEIGHT

POWER CONSUMPTION

POWER REQUIREMENTS

160Hz~12KHz

MIC input : 6mV

DC 24V

180X150X52mm

FLP-PMC012

2W

Balanced

1.25Kg

10FLP-PMC012

Page 12: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

7. DIMENSIONAL DIAGRAM

11 FLP-PMC012

50Over 50Over

Ove

r5

0

UNIT :mm

UNIT :mm

180

15

0

52

52

170

180

FLP-PMC01212 ZONES REMOTE PAGINGMICROPHONE

MIC

1122

33

PUSH

OUTPUT LEVEL

-18 -15 -12 -9 -6 -3 0 +3 +6 +9

-18 -15 -12 -9 -6 -3 0 +3 +6 +9

CH8CH7CH6CH5

CH12CH11CH10CH9

CH4CH3CH2CH1

CHIME ALL TALKPOWER

POWER

CHIMEVOL

MICVOL

MIN MAXMIN MAX

COM1 COM2ZONE1~6 ZONE7~12

MIX OUT

ALL OUT OUT IN

POWER

CHIMEVOL

MICVOL

MIN MAXMIN MAX

COM1 COM2ZONE1~6 ZONE7~12

MIX OUT

ALL OUT OUT IN

POWER 24V 2A

POWER 24V 2A

Page 13: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

PUBLIC ADDRESS SYSTEM

VersionV0.1

Page 14: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

Please follow the instructions in this manual to obtain the optimum results from this unit.We also recommend that you keep this manual handy for future reference.

OPERATION MANUAL

TMTM

PROFESSIONAL PUBLIC ADDRESS SYSTEM

12 ZONES PAGING CONSOLE EXTENSION UNIT

FLP-PMCE012

Page 15: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

TABLE OF CONTENTS

1. SAFETY PRECAUTIONS .......................................................................................3

2. FEATURES ...............................................................................................................5

3. NOMENCLATURE AND FUNCTIONS

3.1 Front Panel ............................................................................................................. 6

3.2 Rear Panel..............................................................................................................6

4. .............................................................................................................7

5. APPLICATIONS .......................................................................................................8

6. SPECIFICATIONS ..................................................................................................9

7. DIMENSIONAL DIAGRAM ...................................................................................10

OPERATION

2

Page 16: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference.

Safety Symbol and Message ConventionsSafety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety

Indicates a potentially hazardous situation which, if mishandled, couldresult in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, couldresult in moderate or minor personal injury, and/or property damage.

When Installing the Unit

Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.

Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.

Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock.

Be sure to replace the unit's terminal cover after connection completion. Because high voltage is applied to the speaker terminals, never touch these terminals to avoid electric shock.

Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe as a catastrophic disaster may result.

Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling down, causing personal injury and/or property damage.

When the Unit is in Use

Should the following irregularity be found during use, immediately switch off the power, disconnect the power supply plug from the AC outlet and contact your nearest dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock. If you detect smoke or a strange smell coming from the unit. If water or any metallic object gets into the unit If the unit falls, or the unit case breaks If the power supply cord is damaged (exposure of the core, disconnection, etc.) If it is malfunctioning (no tone sounds.)

To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to your nearest dealer.

Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock.

Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock.

1. SAFETY PRECAUTIONS

3

Page 17: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated inthe electrical installation of the building.

When Installing the Unit

Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock.

When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.

When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull.

Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and result in fire.

Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock.

When the Unit is in Use

Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage.

Make sure that the volume control is set to minimum position before power is switched on. Loud noise produced at high volume when power is switched on can impair hearing.

Do not operate the unit for an extended period of time with the sound distorting. This is an indication of a malfunction, which in turn can cause heat to generate and result in a fire.

Contact your dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result.

If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely.

Switch off the power, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more. Doing otherwise may cause a fire or electric shock.

SAFETY PRECAUTIONS

4

Page 18: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

2. FEATURES

1. With two RJ45 port for 12 zone triggering.

2. 12 zone switches control witr LED indicator.

3. 24V DC main power supply with link out function.

4. ALL CALL line in and out connector to extend the ALL CALL function to another unit.

5

Page 19: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

3. NOMENCLATURE AND FUNCTIONS

3.1 FRONT PANEL

1

6

2

1. "Power button indicator": mainly used for the power switch indicates when the machine is turned on

LED lights, LED goes off when the machine is turned off.

2. "Partition key control": 12 partitions separate key control buttons, on the front panel corresponding to

CH1 to CH12 keys to control 12 zone if is effective, when the corresponding partition keys are pressed,

indicator lights showing the current partition active.

1

2345

1. The power switch, the main use to make power switch .

2. COM2 interface, with PLC9812 machinery, mainly used to control 7-12 partition PLC9812 machine.

3. COM1 interface, with PLC9812 machinery, mainly used to control 1-6 partition PLC9812 machine.

4. Power input and output interface, mainly used for machine power input, also a DC24V power output,

the power output is not affected by power switch.

5. The region's input and output interface, mainly used to make the machine enter the region, also has

an output to control the region, the region just need to enter "ALL IN" shorting these two ports can

serve to control the region.

3.2 REAR PANEL

Page 20: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

7

1. The COM1 and COM2 will be connected to the left REMOTE SELECT(Z1~Z6) and right REMOTE

SELECT(Z7~Z12) of the FLP-ZS9812MKII respectively.

2. Network cable using the straight-through cable.

3. When press ALL CALL on FLP-ZS9812MKII, all 12 zones LED of FLP-PMC012 and FLP-PMCE012

should be switch on.

4. When press ALL CALL on FLP-PMC012, also all 12 zones LED of FLP-ZS9812MKII and FLP-PMCE012

should switch on.

5. When press ALL CALL on FLP-ZS9812MKII, which connect to FLP-PMCE012, only corresponding

FLP-PMCE012 12 zones LED are switch on. 12 zones for other FLP-PMC012 and other FLP-PMCE012

and other FLP-ZS9812MKII cannot switch on.

NOTE: the instructions refer to the instructions used in conjunction with FLP-ZS9812MKII.

4. OPERATION

Page 21: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

REAR PANEL CONNECTIONS

8

POWER

CHIMEVOL

MICVOL

MIN MAXMIN MAX

COM1 COM2ZONE1~6 ZONE7~12

MIX OUT

ALL OUT OUT IN

RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIRAVIS:

RISK OF ELECTRIC SHOCKDO NOT OPEN

POWER 24V 2A

DC24V+ -

RELAY TRIG

RELAY CON T

REMOTE SELECT

PIN 1-Z1PIN 2-Z2PIN 3-Z3PIN 4-Z4PIN 5-Z5PIN 6-Z6PIN 7-ACPIN 8-PR

AMP 1

10

0V

CO

M

ZONE 11

00

V

CO

M

AMP 2

10

0V

CO

M

ZONE 2

10

0V

CO

M

AMP 3

10

0V

CO

M

ZONE 3

10

0V

CO

M

AMP 4

10

0V

CO

M

ZONE 4

10

0V

CO

M

AMP 5

10

0V

CO

M

ZONE 5

10

0V

CO

M

AMP 6

10

0V

CO

M

ZONE 6

10

0V

CO

M

AMP 9

10

0V

CO

M

ZONE 9

10

0V

CO

M

AMP10

10

0V

CO

M

ZONE10

10

0V

CO

M

AMP 7

10

0V

CO

M

ZONE 7

10

0V

CO

M

AMP 8

10

0V

CO

M

ZONE 8

10

0V

CO

M

AMP11

10

0V

CO

M

ZONE11

10

0V

CO

M

AMP12

10

0V

CO

M

ZONE12

10

0V

CO

MREMOTE SELECT

PIN 1-Z7PIN 2-Z8PIN 3-Z9PIN 4-Z10PIN 5-Z11PIN 6-Z12PIN 7-ACPIN 8-GND

AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 1 TO 6 AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 7 TO 12

DC24V+ -

RELAY TRIG

RELAY CON T

REMOTE SELECT

PIN 1-Z1PIN 2-Z2PIN 3-Z3PIN 4-Z4PIN 5-Z5PIN 6-Z6PIN 7-ACPIN 8-PR

AMP 1

10

0V

CO

M

ZONE 1

10

0V

CO

M

AMP 2

10

0V

CO

M

ZONE 2

10

0V

CO

M

AMP 3

10

0V

CO

M

ZONE 3

10

0V

CO

M

AMP 4

10

0V

CO

M

ZONE 4

10

0V

CO

M

AMP 5

10

0V

CO

M

ZONE 5

10

0V

CO

M

AMP 6

10

0V

CO

M

ZONE 6

10

0V

CO

M

AMP 9

10

0V

CO

M

ZONE 9

10

0V

CO

M

AMP10

10

0V

CO

M

ZONE10

10

0V

CO

M

AMP 7

10

0V

CO

M

ZONE 7

10

0V

CO

M

AMP 8

10

0V

CO

M

ZONE 8

10

0V

CO

M

AMP11

10

0V

CO

M

ZONE11

10

0V

CO

M

AMP12

10

0V

CO

M

ZONE12

10

0V

CO

MREMOTE SELECT

PIN 1-Z7PIN 2-Z8PIN 3-Z9PIN 4-Z10PIN 5-Z11PIN 6-Z12PIN 7-ACPIN 8-GND

AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 1 TO 6 AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 7 TO 12

DC24V+ -

RELAY TRIG

RELAY CON T

REMOTE SELECT

PIN 1-Z1PIN 2-Z2PIN 3-Z3PIN 4-Z4PIN 5-Z5PIN 6-Z6PIN 7-ACPIN 8-PR

AMP 1

10

0V

CO

M

ZONE 1

10

0V

CO

M

AMP 2

10

0V

CO

M

ZONE 2

10

0V

CO

M

AMP 3

10

0V

CO

M

ZONE 3

10

0V

CO

M

AMP 4

10

0V

CO

M

ZONE 4

10

0V

CO

M

AMP 5

10

0V

CO

M

ZONE 5

10

0V

CO

M

AMP 6

10

0V

CO

M

ZONE 6

10

0V

CO

M

AMP 9

10

0V

CO

M

ZONE 9

10

0V

CO

M

AMP10

10

0V

CO

M

ZONE10

10

0V

CO

M

AMP 7

10

0V

CO

M

ZONE 7

10

0V

CO

M

AMP 8

10

0V

CO

M

ZONE 8

10

0V

CO

M

AMP11

10

0V

CO

M

ZONE11

10

0V

CO

M

AMP12

10

0V

CO

M

ZONE12

10

0V

CO

MREMOTE SELECT

PIN 1-Z7PIN 2-Z8PIN 3-Z9PIN 4-Z10PIN 5-Z11PIN 6-Z12PIN 7-ACPIN 8-GND

AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 1 TO 6 AMPLIFIER INPUTS-ZONE OUTPUTS FOR ZONE 7 TO 12

5. APPLICATIONS

Page 22: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

6.SPECIFICATIONS

MODEL

POWER REQUIREMENTS

NETWORK INTERFACE

OPERATING TEMPERATURE

WEIGHT

DIMENSION

OPERATING HUMIDITY

RJ45

5 ~40

20%~80% Relative humidity, non condensing

1.25kg

FLP-PMCE012

143x135x55mm

DC 24V

9

Page 23: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

7. DIMENSIONAL DIAGRAM

10

Page 24: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

Version 0.1

TMTM

Page 25: FLP-PMC-012 + PMCE-012 - Public Address System · Model Power Requirement Power Consumption Output Level S/N Ratio Frequency Response Dimension (D x W x H) Weight Material & Finish

MANUFACTURER / IMPORTER TEST LABORATORY

This is the result of test, that was carried out from the submitted type-samples of a product in conformity with the specification of the respective standards. The declaration holder has the right to fix the CE-mark for EMC on the product complying with the inspection sample

09 August 2014

(Date) (Date)

(Surname, forename) (Company stamp)

(Company stamp) CTS (Ningbo) Testing Service Technology Co., Ltd.

NB test site:2/F., South Tower, Huoju Building, No.181, Canghai Road, Jiangdong Science and Technology Park, Ningbo, Zhejiang, China

GZ test site: A101, No.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China

CTS (NINGBO) TESTING SERVICE TECHNOLOGY OPERATE ACCORDING TO ISO/IEC 17025

EC DECLARATION OF CONFORMITY EU - ELECTROMAGNETIC COMPATIBILITY DIRECTIVE -

This declares that the following designated product

Paging Microphone Model No.: FLP-PMC001, FLP-PMC010, FLP-IP6702, FLP-PMC012, FLP- PMCE012

Brand Name: FLEPCHER (Product identification)

Complies with the essential protection requirements of the European Parliament and of the Council Directive 2004/108/EC on the approximation of the laws of the Member States relating

to electromagnetic compatibility. This declaration applies to all specimens manufactured in accordance with the attached

manufacturing drawings which form part of this declaration. Assessment of compliance of the product with the requirements relating to electromagnetic

compatibility was based on the following standards:

EN 55013: 2013 EN 61000-3-2: 2006+A2:2009, EN 61000-3-3: 2008

EN 55020:2007+A11 :2011 (Identification of regulations / standards)

This declaration is the responsibility of the Applicant / importer Flepcher Sdn Bhd

9, Jalan Kenari 10, Bandar Puchong Jaya, 47100 Puchong, Selangor, Malaysia

(Name / Address)

THIS DOC IS ONLY VALID IN CONNECTION WITH TEST REPORT NUMBER: CGZ3140702-00695-E-D

Fi03
新建图章