www.powrmatic.co.uk Flue Brochure Flue and Chimney Systems Powrmatic Ireland Through our sister company SFL, Powrmatic offers both single wall and twin wall flue/chimney systems for both gas and oil fired, condensing and non-condensing appliances to suit all applications and budgets. Powrmatic Ireland Flue & Chimney Range.

Upload: others

Post on 29-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • www.powrmatic.co.uk

    Flue BrochureFlue and Chimney SystemsPowrmatic Ireland

    Through our sister company SFL, Powrmatic offers both single wall and twin wall flue/chimney systems for both gas and oil fired, condensing and non-condensing appliances to suit all applications and budgets. Powrmatic Ireland Flue & Chimney Range.

  • POWRMATIC®

    Delivering complete climate control solutions worldwide

    Company OverviewWith flue diameters up to 1200 mm, combined with many years’ experience of supplying pre-fabricated chimney systems, Powrmatic is the ideal partner for chimney, venting and exhaust systems for commercial and industrial applications. Maximum flexibility is as-sured by our manufacturing capabilities, enabling special components to be produced in a timely manner.

    Powrmatic also offers full technical support covering areas such as design, sizing and regulatory compliance.

    2

  • Price List Index

    Sflue--------------------------------------------------------------------------------------------Pages 4-11

    Supra +----------------------------------------------------------------------------------Pages 12-26

    Nova--------------------------------------------------------------------------------------------Pages 27-45

    IL-------------------------------------------------------------------------------------------------------Pages 46-47

    Sigma----------------------------------------------------------------------------------------Pages 48-51

    Accessories---------------------------------------------------------------------Pages 52-53

    3

  • Straight LengthAvailable in nominal installed lengths of 120mm, 300mm, 500mm, 1000mm.

    ø 120mm Code 300mm Code 500mm Code 1000mm Code127mm 2110605 2141105 2141005 2140905

    152mm 2110606 2141106 2141006 2140906

    178mm 2110607 2141107 2141007 2140907

    203mm 2110608 2141108 2141008 2140908

    Adjustable LengthThe telescopic adjustable length offers a degree of flexibility when standard length dimensions are not suitable. All adjustable lengths are supplied with separate insulating material for insertion into the annulus once the installed length has been determined. Includes a clamp band as standard.

    Short Adjustable Length Long Adjustable Lengthø Min Max Code Min Max Code

    127mm 200 325 2144005 350 530 2141205152mm 200 325 2144006 350 530 2141206178mm 200 325 2144007 350 530 2141207203mm 200 325 2144008 350 530 2141208

    Adjustable Slip SectionDesigned to fit over any standard length and offers a degree of flexibility when standard dimensions are not suitable. Bottom length not included. Supplied with separate insulation and a clamp band. Only to be used to extend standard lengths.

    ø Min(mm) Max(mm) Code

    127mm 30 256 2143005

    152mm 30 244 2143006

    178mm 30 244 2143007

    203mm 30 244 2143006

    The adjustable components above are not load bearing, always use a support component directly above when vertically applied.

    Inspection LengthA 500mm length incorporating a removable door for inspection & cleaning.

    ø A(mm) Code

    127mm 500 2141805

    152mm 500 2141806

    178mm 500 2141807

    203mm 500 2141808

    Tapered Adaptor LengthOffers an aesthetic transition from single wall connecting flue pipe to Sflue.

    ø A(mm) B(mm) Code127mm 865 1015 2140405152mm 865 1015 2140406

    This component should only be fitted to a single wall connecting flue pipe, and not directly to the appliance.

    AB

    A

    MinMax

    MinMax

    LengthsSflue

    4

  • ElbowsSflue

    2 Segment Elbows (15°/ 30°/ 45°)Provides a change of direction, measured from the vertical by the specified angle. Elbows are supplied with an un-barbed female coupler (to allow for 360° rotations) and bolted locking band for rigid joint bracing, especially when used as an offset around gutters and fascia boards.

    Angle 15° 30° 45°ø Code Code Code

    127mm 2131405 2132305 2132205152mm 2131406 2132306 2132206178mm 2131407 2132307 2132207203mm 2131408 2132308 2132208

    3 Segment 90° ElbowProvides a 90° change of direction.

    ø A(mm) B(mm) C(mm) Code127mm 87 126 148 2145305152mm 92 136 157 2145306178mm 97 144 165 2145307203mm 102 156 174 2145308

    A

    B

    Single wall imperial stainless steel connecting flue pipe.For wood and multi-fuel appliances.Available in 5”-8” internal diameter.

    Connecting Flue

    Complementary SFL Product

    BS EN 1856-2 T600 N1 D V3 L50010 G400 M

    SIGMA 1MM

    www.powrmatic.ie

    A

    C

    5

  • Tees & Tee ComponentsSflue

    90° Equal TeeUsed at the base of a vertical chimney from a horizontal stove outlet, or as an inspection opening.

    ø A(mm) B(mm) C(mm) Code127mm 305 152 152 2114305152mm 325 162 162 2114306178mm 350 175 175 2114307203mm 375 187 187 2114308

    135° TeeUsed at the base of a vertical chimney, or to allow a smooth transition from the horizontal to vertical plain when used with a 45° elbow. The coupler on the branch is unbarbed to allow unlimited rotational adjustment and includes a bolted locking band.

    Dimension (mm) With 45° Elbow ø A(mm) B(mm) C(mm) D(mm) Code127mm 495 340 388 38 2141305152mm 495 375 422 45 2141306178mm 745 420 463 54 2141307203mm 745 450 492 60 2141308

    Tee Cap with DrainUsed at the bottom of a vertical chimney to facilitate drainage and cleaning. Fitted with a stainless steel 1” BSP external thread drain connection.

    ø Code127mm 2153205152mm 2153206178mm 2153207203mm 2153208

    Tee CapUsed to close off the branch or base of a tee, or for use as an access/inspection/cleaning component.

    ø Code127mm 2119105152mm 2119106178mm 2119107203mm 2119108

    A

    B

    C

    BA

    A

    B

    C

    AB

    C

    D

    6

  • Floor Penetration & Firestop ComponentsSflue

    Combustible floors - solid fuel and oil fired appliance’s (T450)The following components must be used when Sflue is fitted to a solid fuel or oil fired appliance, when the flue gas temperature will not exceed 450°C, and/or where the chimney system penetrates a combustible floor. Each ventilated component offers a 50mm distance to combustible materials.Intumescent Sealant (1099900) is required for the correct installation of ventilated components, available on page 13.

    Standard Ventilated Ceiling Support Kit (T450)Used to both support and firestop the chimney system when it passes through the first combustible floor, directly above the appliance. The support component incorporates a patented intumescent matrix design which expands rapidly with temperature and seals the plate to prevent the potential spread of fire or smoke from the room below. Also available painted black (add a ZB to the code), or white (add a ZW to the code).

    ø A(mm) B(mm) C(mm) Code 127mm 361 281 379 2172705152mm 381 301 399 2172706178mm 411 331 429 2172707203mm 431 351 453 2172708

    D5 White Ventilated Ceiling Support Kit (T450)Used as per the standard version. The D5 offers an aesthetically pleasing flat appearance where the chimney passes through the ceiling penetration and uses minimal ventilation openings. This component is finished in a high quality white gloss finish.

    ø A(mm) B(mm) Code127mm 352 279 2188805152mm 372 299 2188806178mm 402 329 2188807203mm 422 349 2188808

    Ventilated Firestop (T450)Used where the chimney passes through the upper combustible floors, and where sections below the floor are enclosed within a non combustible shaft. This item is not load-bearing.

    ø A(mm) B(mm) Code127mm 379 281 2188705152mm 399 301 2188706178mm 331 429 2188707203mm 355 453 2188708

    A B

    Non-combustible floorsThe following components can be used on applianc-es where the flue gas temperature does not exceed 250°C, and/or where the chimney passes through a non-combustible floor.

    Ceiling SupportProvides a 50mm air gap clearance to a penetrated floor or ceiling and is only used where Sflue penetrates a non-combustible floor, and/or services a gas or oil fired appliance where the flue gas temperature does not exceed 250°C.

    ø A(mm) B(mm) Code127mm 330 280 2102705152mm 355 305 2102706178mm 381 331 2102707203mm 406 356 2102708

    Firestop SpacerUsed to provide location, fire and dust stopping where Sflue is used through non-combustible floors, and/or services an appliance where the flue gas temperatures does not exceed 250°C. This item is not load bearing.

    ø A(mm) B(mm) Code127mm 330 280 2108705152mm 355 305 2108706178mm 381 331 2108707203mm 406 356 2108708

    B

    A B

    A

    C

    AB

    A B

    +

    Upper floor (Ventilated Firestop)

    First floor(Ventilated Ceiling Support)

    Apply a bead of intumescent sealant around the flange.

    www.powrmatic.ie7

  • Support ComponentsSflue

    Support Length (Strut/Guy Attachment)A 100mm installed length which incorporates a support plate located 33mm from the bottom edge and features slotted holes for rotational adjustment, for fixing to bespoke bracketry. This component also doubles as a strut / guy attachment length offering anchoring points to which guys, or preferably rigid stays can be secured using M8 nuts and bolts.

    ø Code127mm 2171305152mm 2171306178mm 2171307203mm 2171308

    Wall Support BracketUsed to take the vertical load of the chimney when supported from a wall. The support bracket is fully adjustable allowing varying clearances from the wall (50mm-150mm). Requires M10 wall fixings. Support length included.Stainless

    ø A(mm) B(mm) C(mm) Code127mm 282 311 265 2151705152mm 302 331 285 2151706178mm 331 360 314 2151707203mm 355 384 338 2151708

    Galvanised127mm 282 311 265 2151805152mm 302 331 285 2151806178mm 331 360 314 2151807203mm 355 384 338 2151808

    Single Wall to Sflue Anchor PlateDesigned to be used when connecting Sflue to a lintel or pre-cast chamber. A short section of liner projects a nominal 150mm through the bottom of the plate. This component could also be used to connect a flexible liner to Sflue on a capped chimney within the attic space. Maximum Load: 13m.

    ø A(mm) B(mm) C(mm) Code127mm 123 400 350 2152705152mm 148 400 350 2152706178mm 179 400 350 2152707203mm 204 400 350 2152708

    Bracing BracketA clamping collar for the attachment of struts/supports.

    ø Code127mm 2109205152mm 2109206178mm 2109207203mm 2109208

    Wall BandWall bands provide lateral support for the chimney and must be used at intervals not exceeding 3.0 metres beyond any load bearing support.

    ø A(mm) Code(S/S) Code(Galv)127mm 137 3115155 3116155152mm 162 3115205 3116205178mm 192 3115234 3116234203mm 212 3115235 3116255

    Wall Band Extension Pieces Where externally applied, the intervals between Wall Band fixing centres must be reduced from 3.0 metres to 2.5 metres. The maximum clearance is as detailed below. Available in both stainless steel and galvanised steel.

    ø Min Max Code(S/S) Code(Galv)All 50 100 3119136 3120136

    Heavy Duty Wall Band (S/S) Can also be used as a conventional wall band.

    ø A(mm) B(mm) Code127mm 250 112.5 3109512152mm 270 126 3109515178mm 300 139 3109517203mm 320 152 3109520

    Extension Brackets (S/S)Size A(mm) CodeShort 324 31093ST

    Medium 395 31093MDLong 600 31093LG

    Roof/Rafter SupportDesigned to allow a chimney to be supported on roof joists, trussed rafters etc. Supplied with a diameter specific rotational clamp band. Maximum suspended chimney length supported is 6 metres and maximum total length supported is 9 metres. Suits up to 600mm rafter span.

    ø A(mm) B(mm) Code127mm 617 206 7072612152mm 643 232 7072615178mm 669 258 7072617203mm 694 283 7072620

    Universal Roof/Rafter Support As the Roof/Rafter Support above, but with a gimbal plate that is universal across all diameters. The gimbal plate is adjusted on site to match the diameter of the chimney. Suits up to 600mm rafter span. Each item consists of 2 supports.

    ø A(mm) B(mm) CodeAll 203 220 7002900

    CB

    C

    BA

    A

    B

    AB

    A

    A

    B

    A

    8

  • AdaptorsSflue

    Appliance Adaptor Installation

    Use ceramic rope or fire cement when installing an adaptor to the stove outlet.

    Adaptors will suit most types of single wall connecting pipe.

    Appliance AdaptorUsed to connect the appliance outlet to the Sflue chimney system. Also used to connect Sflue to single wall connecting flue pipe.

    ø A(mm) O.D. Code127mm 36 123 2119405152mm 36 148 2119406178mm 36 178 2119407203mm 36 198 2119408

    Adaptor to Cast IronA crimped, reduced inner section to adapt a cast iron stove outlet directly to Sflue. Features an outer sleeve for improved aesthetics.

    ø A(mm) O.D. Code127mm 103 114 2119505152mm 103 139 2119506178mm 103 165 2119507203mm 103 190 2119508

    Sflue to Flex AdaptorUsed to connect Sflue to a flexible flue liner.

    ø(I.D) (O.D)

    CodeA(mm) B(mm)127mm 134 125 2150105152mm 161 145 2150106178mm 187 175 2150107203mm 218 195 2150108

    Flex to Sflue AdaptorUsed to connect from a flexible flue liner to Sflue.

    ø A(mm) B(mm) Code127mm 132.5 125 2150205152mm 157.5 145 2150206178mm 190 171 2150207203mm 213 196 2150208

    Short Tapered AdaptorOffers an aesthetic transition from the single wall connecting flue pipe to an Sflue chimney system.

    ø A(mm) Code127mm 150 2140505152mm 150 2140506

    This component should only be fitted to a single wall connecting flue pipe, and not directly to the appliance.

    Sflue IncreaserAn increaser to facilitate an increase in diameter size between Sflue components.

    ø Flue size A(mm) Code127mm 152 2151005127mm 178 2154805127mm 203 2154905152mm 178 2150606152mm 203 2154806178mm 203 2151207

    Appliance Increaser AdaptorUsed to increase from the appliance outlet size by one diameter size.

    ø A(mm) O.D. Code127mm 30 97 2119705152mm 30 123 2119706178mm 30 148 2119707203mm 30 173 2119708

    A

    O.D.

    A

    O.D. A

    O.D.A

    B

    ø

    A

    A

    B

    Mechanical fixings such as screws or rivets should not be used to secure an adaptor to the spigot or connecting flue pipe.

    www.powrmatic.ie9

  • TerminalsSflue

    Top StubThe Top Stub offers the least resistance to flue gases and are ideal for solid fuel and oil fired appliances, providing there is drainage at the base of the chimney.

    ø A(mm) Code127mm 228 2117305152mm 228 2117306178mm 228 2117307203mm 228 2117308

    Rain CapThe Rain Cap offers a degree of protection from rain and is suitable for solid fuel and oil fired appliances.

    ø Code127mm 2107405152mm 2107406178mm 2107407203mm 2107408

    Rain Cap with 1” MeshAs the Rain Cap above, but with a mesh incorporated to protect from birds.

    ø Code127mm 2107605152mm 2107606178mm 2107607203mm 2107608

    Storm CowlThe Storm Cowl is designed to offer maximum protection against driving rain and strong winds. Please note that this is not an anti-down draught terminal. For solid fuel applications, the Round Top would be recommended.

    ø A(mm) B(mm) Code127mm 294 175 2148705152mm 319 188 2148706

    178mm 344 188 2148707

    203mm 369 210 2148708

    Round TopThe Round Top offers strong protection against driving rain and wind, recommended for exposed locations. The new design features a barbed coupler and a step for easier installation.

    ø A(mm) B(mm) Code127mm 255 234 2107505152mm 300 234 2107506178mm 358 234 2107507203mm 402 234 2107508

    Solid Fuel Chimney Termination HeightsTermination for solid fuel and oil are subject to EN 15287. The illustration below is for solid fuel. If the chimney serves an oil-fired pressure jet appliance, the chimney must discharge a minimum of 600mm above the roof penetration point, or any adjacent structure, if it is within 750mm. The chimney must also terminate at least 600mm from any opening into the building and 300mm from any combustible material. For domestic natural gas appliances, chimney termination heights are governed by BS EN 5440-1.Minimum distance measured from the top of the chimney construction, excluding any pot or terminal:

    A 2.3 metres horizontally clear of the roof surface, e.g. if the roof pitch is 45°, then the chimney should project 2.3 metres above it, and:

    a) At least 1m above the highest point of intersection of the chimney and weather surface; or

    b) At least as high as the ridge.

    B 1.0 metre, provided A is satisfied, or 600mm above the ridge if G is less than 600mm.

    C 1.0 metre above the top of any flat roof, and the top of any openable roof light, dormer window or ventilator, etc., if it is located within 2.3 metres.

    D/E If D is less than 2.3 metres, E shall be not less than 600mm.

    F 600mm above the ridge.

    G If G is within 600mm of the ridge then B shall be 600mm above the ridge.

    A

    AB

    CE

    F

    G

    D

    A

    B

    A

    B

    10

  • AccessoriesSflue

    Sprung Locking BandA locking band must be used on all joints and is included with each component that has a female coupler.

    ø Code127mm 2108605152mm 2108606178mm 2108607203mm 2108608

    Bolted Locking BandA screw-toggle locking band is provided as standard with the unbarbed female coupler on elbows and 135° tee branches. Can be used to provide extra strength on a joint.

    ø Code127mm 2108605MT152mm 2108606MT178mm 2108607MT203mm 2108608MT

    Intumescent SealantRequired for the correct installation of the Ventilated Ceiling Support Kits & Firestops

    Code290ml 0199900

    Angled Wall Cover Rings

    90° Trim CollarThis item is used to offer an aesthetic closing ring where a chimney passes through an outside wall. Manufactured from polished stainless steel.

    ø A(mm) B(mm) Code127mm 108 394 2108505152mm 103 409 2108506178mm 105 444 2108507203mm 108 474 2108508

    45° Adjustable Wall Sleeve Must be used where a 135° tee is used to pass the chimney through an external masonry wall and provides a continuous, uninterrupted run through the wall. Provides clearance of 25mm as standard. Adjustable for a wall thickness of 200mm - 380mm. Once extended, the joint must be secured with self-tapping screws and covered around the circumference with a heat resistant foil duct tape. Available in both stainless steel and galvanised steel.Not suitable for applications where the wall construction may contain combustible materials.

    Stainless Steel (Masonry)ø A(mm) Min Max Code

    127mm 237 200 380 3107305152mm 257 200 380 3107306178mm 287 200 380 3107307203mm 311 200 380 3107308

    Galvanised Steel (Masonry)ø A(mm) Min Max Code

    127mm 237 200 380 3107105152mm 257 200 380 3107106178mm 187 200 380 3107107203mm 311 200 380 3107108

    Structural Locking BandRequired for added security on unsupported stacks up to 2.5m above the final support or wall band, in accordance with the instructions.

    ø Code127mm 2159805152mm 2159806178mm 2159807203mm 2159808

    Angled Wall Cover Ring (2-Piece)Designed to offer an aesthetic trim around the chimney where it penetrates the wall at an angle. The component is available in 5 angle variations.

    ø A(mm)0-10° 10-20° 20-30° 30-40° 40-50°Code Code Code Code Code

    127mm 159 7071212 7071312 7070012 7070312 7070212152mm 146.5 7071215 7071315 7070015 7070315 7070215

    A

    A

    495mm

    A

    B

    Min

    Max

    www.powrmatic.ie11

  • LengthsSupra Plus

    Straight LengthsAvailable in ‘nominal’ installed lengths as detailed in the tables below

    ØInstalled Length

    974mm 474mm80mm 4110108 4110208

    100mm 4110110 4110210130mm 4110113 4110213150mm 4110115 4110215180mm 4110118 4110218200mm 4110120 4110220250mm 4110125 4110225300mm 4110130 4110230350mm 4110135 4110235

    ØInstalled Length

    224mm 98mm80mm 4110308 4110708

    100mm 4110310 4110710130mm 4110313 4110713150mm 4110315 4110715180mm 4110318 4110718200mm 4110320 4110720250mm 4110325 4110725300mm 4110330 4110730350mm 4110335 4110735

    Probe LengthA 224mm installed length featuring a test point, closed via a 1/4” BSP screw.

    Ø Code80mm 4110908

    100mm 4110910130mm 4110913150mm 4110915180mm 4110918200mm 4110920250mm 4110925300mm 4110930350mm 4110935

    Damper Length (P1 Only)Used to increase resistance / reduce draught in a system or at appliance connection. This is not a reflux device and is manually set. The damper blade provides a maximum closure of 70%. Only suitable for positive pressure applications up to 200 Pa (P1).

    Ø A Code100mm 230 4119610130mm 230 4119613150mm 230 4119615180mm 230 4119618

    200mm 230 4119620

    250mm 230 4119625

    Inspection Length (P1 Only)Designed to be installed within the system to allow access for inspection and cleaning. The door closes on an elastomer seal to provide a condensate and pressure resistant joint and must only be used where the flue gas temperature will not exceed 200°C. For high temperature applications the door seal must be removed prior to installation.

    Ø A B Code80mm 475 100 4111008

    100mm 475 100 4111010130mm 475 180 4111013150mm 475 200 4111015180mm 475 200 4111018200mm 475 200 4111020250mm 475 200 4111025300mm 475 200 4111030350mm 475 200 4111035

    Adjustable LengthDesigned to be used to make up a required length between two components. It should only be used with a standard length which must be ordered separately. Minimum length of adjustment is set to give an engagement of half of the flue diameter. Adjustable Lengths are also supplied with a special Gasket Set which must be used for condensing and positive pressure applications. Adjustable Lengths can be cut to size on site if required.

    Ø A MIN A MAX Code80mm 63 306 4114408

    100mm 63 296 4114410130mm 63 281 4114413150mm 63 271 4114415180mm 63 243 4114418200mm 63 233 4114420250mm 63 208 4114425300mm 63 183 4114430350mm 63 158 4114435

    Seal Lubricant Lubricant must be applied around the circumference of the fitted seal, providing a lubricated interface between the seal and the liner when the product is used for positive pressure and wet applications. A single bottle will lubricate many seals and will be sufficient for several system installations.

    Seal Lubricant (250ml) 3107500

    Notes: The SFL Seal Lubricant has been specifically formulated for use with SFL EPDM and Silicone Seals. Failure to use SFL Lubricant when installing seals in Supra Plus may invalidate the product warranty and limit the working life of the seal.

    Inst

    alle

    d Le

    ngth

    A

    AB

    A

    www.powrmatic.ie12

  • AdaptorsSupra Plus

    Appliance AdaptorUsed to connect the SUPRA Plus product to the appliance. The interface between the Adaptor and the appliance outlet should be sealed with silicone sealant when used on condensing appliances, unless the appliance incorporates a seal at the outlet.

    Ø A(mm) B(mm) OD Code80mm 55 105 77 4119308

    100mm 55 105 97 4119310130mm 55 105 127 4119313150mm 55 105 147 4119315180mm 55 105 177 4119318200mm 55 105 197 4119320250mm 55 105 247 4119325300mm 55 105 297 4119330350mm 55 105 347 4119335

    SUPRA Plus - NOVA® AdaptorDesigned to facilitate connection from the SU-PRA Plus to NOVA® chimney system.

    Ø Code80mm SUPRA Plus to 100mm

    NOVA®4179608

    100mm 4179610130mm 4179613150mm 4179615180mm 4179618200mm 4179620250mm 4179625300mm 4179630350mm 4179635

    Adaptor to Flex (P1)Used to connect the SUPRA Plus product to a generic liner providing it meets the dimension of the adaptor. Supplied with easy fit clamping band.

    Ø A(mm) B(mm) C(mm) Code100mm 96 113 88 4111710130mm 121 138 88 4111713150mm 146 163 88 4111715180mm 171 190 88 4111718200mm 196 213 88 4111720250mm 246 263 88 4111725300mm 296 313 88 4111730350mm 346 363 88 4111735

    Adaptor from Flex (P1)Used to connect the SUPRA Plus product from a generic liner, providing it meets the dimension of the adaptor. Supplied with an easy fit clamping band, see page 17.

    Ø A(mm) B(mm) C(mm) Code100mm 96 113 138 4112110130mm 121 138 138 4112113150mm 146 163 138 4112115180mm 171 193 138 4112118200mm 196 213 138 4112120250mm 246 263 138 4112125300mm 296 313 138 4112130350mm 346 363 138 4112135

    80mm SUPRA Plus - 100mm Flex Adaptor (P1)Used to connect from 80mm SUPRA Plus to 100mm generic flexible chimney liner. Supplied with easy fit clamping band.

    Ø A(mm) B(mm) C(mm) Code80 96 113 117 4117908

    Supra / Supra Plus Conversion AdaptorsSupra Plus is the latest iteration of our single wall system for positive pressure condensing applications and supersedes the original Supra product. SFL offer conversion adaptors to convert to and from existing Supra installations.

    Ø SUPRA Plus-SUPRA

    SUPRA-SUPRA Plus

    80mm 4111508 4111608100mm 4111510 4111610130mm 4111513 4111613150mm 4111515 4111615180mm 4111518 4111618200mm 4111520 4111620250mm 4111525 4111625300mm 4111530 4111630350mm 4111535 4111635

    A

    B

    OD

    80m

    m

    AB

    C

    C

    AB

    BA

    C

    13

  • TeesSupra Plus

    90° TeeUsed to provide a 90° connection in a system or can be used as an access / inspection point when used with a Tee Cap

    Ø A B C Code80mm 285 131 90 4110508

    100mm 285 131 90 4110510130mm 315 146 105 4110513150mm 335 156 115 4110515180mm 365 171 130 4110518200mm 387 183 142 4110520250mm 437 208 167 4110525300mm 484 215 190 4110530350mm 534 255 215 4110535

    93° Equal TeeThe tee is provided with a 3° connection on the branch to allow for condensate drainage.

    Ø A B C Code80mm 285 131 90 4110608

    100mm 285 131 90 4110610130mm 315 146 105 4110613150mm 335 156 115 4110615180mm 365 171 130 4110618200mm 387 183 142 4110620250mm 437 208 167 4110625300mm 484 215 190 4110630350mm 534 255 215 4110635

    95° Equal TeeThe tee is provided with a 5° connection on the branch to allow for condensate drainage.

    Ø A B C Code80mm 285 131 90 4119108

    100mm 285 131 90 4119110130mm 315 146 105 4119113150mm 335 156 115 4119115180mm 365 171 130 4119118200mm 387 183 142 4119120250mm 437 208 167 4119125300mm 484 215 190 4119130350mm 534 255 215 4119135

    135° Equal TeeUsed to provide a 45° connection in a system or as a chimney entry point. Can be used as an access / inspection point when used with a Tee Cap, or as a drain when fitted with a Tee Cap with Drain.

    Ø A B C Code80mm 226 129 129 4112208N

    100mm 253 153 153 4112210N130mm 296 189 189 4112213N150mm 325 213 213 4112215N180mm 367 249 249 4112218N200mm 395 274 274 4112220N250mm 465 334 334 4112225N300mm 536 393 393 4112230N350mm 607 455 455 4112235N

    Dimensions with 45° Elbow Added

    Ø E G80mm 250 193

    100mm 274 214130mm 311 250150mm 335 273180mm 371 310200mm 395 335250mm 455 395300mm 523 475350mm 583 536

    C

    A

    B

    C

    A

    B

    C

    E

    G

    C

    A

    B

    A

    B

    14

  • www.powrmatic.ie

    Reducing TeesSupra Plus

    Body ø D1 Branch ø D2 A B C 90° 93° 95°

    100 80 83 198 72 4159001N 4159301N 4159501N

    130 80 98 198 72 4159004N 4159304N 4159504N

    130 100 98 218 82 4159005N 4159305N 4159505N

    150 80 108 198 72 4159009N 4159309N 4159509N

    150 100 108 218 83 4159012N 4159312N 4159512N

    150 130 108 248 97 4159016N 4159316N 4159516N

    180 80 123 198 72 4159017N 4159317N 4159517N

    180 100 123 218 82 4159019N 4159319N 4159519N

    180 130 123 248 97 4159022N 4159322N 4159522N

    180 150 123 268 107 4159023N 4159323N 4159523N

    200 80 133 198 72 4159024N 4159324N 4159524N

    200 100 133 218 82 4159026N 4159326N 4159526N

    200 130 133 248 97 4159028N 4159328N 4159528N

    200 150 133 268 107 4159029N 4159329N 4159529N

    200 180 133 298 122 4159031N 4159331N 4159531N

    250 80 158 198 72 4159032N 4159332N 4159532N

    250 100 158 218 82 4159033N 4159333N 4159533N

    250 130 158 248 97 4159036N 4159336N 4159536N

    250 150 158 268 107 4159037N 4159337N 4159537N

    250 180 158 298 122 4159038N 4159338N 4159538N

    250 200 158 318 132 4159039N 4159339N 4159539N

    300 80 183 198 72 4159041N 4159341N 4159541N

    300 100 183 218 82 4159042N 4159342N 4159542N

    300 130 183 248 97 4159043N 4159343N 4159543N

    300 150 183 268 107 4159046N 4159346N 4159546N

    300 180 183 298 122 4159047N 4159347N 4159547N

    300 200 183 318 132 4159048N 4159348N 4159548N

    300 250 183 368 157 4159049N 4159349N 4159549N

    350 80 208 198 72 4159051N 4159351N 4159551N

    350 100 208 218 82 4159052N 4159352N 4159552N

    350 130 208 248 97 4159054N 4159354N 4159554N

    350 150 208 268 107 4159056N 4159356N 4159556N

    350 180 208 298 122 4159057N 4159357N 4159557N

    350 200 208 318 132 4159058N 4159358N 4159558N

    350 250 208 368 157 4159059N 4159359N 4159559N

    A

    B

    C

    D1

    D2

    15

  • Tee Components & DrainsSupra Plus

    Tee CapUsed to close off the branch / base of a tee or the end of a header/manifold. Held in position with a Locking Band.

    Ø A(mm) Code80mm 70 4114908

    100mm 70 4114910130mm 70 4114913150mm 70 4114915180mm 70 4114918200mm 70 4114920250mm 70 4114925300mm 70 4114930350mm 70 4114935

    Tee Cap with DrainUsed at the bottom of a vertical run, usually under a tee, to facilitate drainage of condensates from the system. The component includes a stainless steel BSP connection to allow drainage pipework to be connected.

    Ø B Code80mm 1" BSP 4114308

    100mm 1" BSP 4114310130mm 1" BSP 4114313150mm 1" BSP 4114315180mm 1" BSP 4114318200mm 1" BSP 4114320250mm 1" BSP 4114325300mm 1" BSP 4114330350mm 1" BSP 4114335

    Tee Cap with Offset DrainAs the previous item, but with a drain on the rim.

    Ø B Code80mm 1" BSP 4116908

    100mm 1" BSP 4116910130mm 1" BSP 4116913150mm 1" BSP 4116915180mm 1" BSP 4116918200mm 1" BSP 4116920250mm 1" BSP 4116925300mm 1" BSP 4116930350mm 1" BSP 4116935

    Horizontal Duct Drain c/w CapUsed as a drainage point on the end of an inclined manifold or inclined run. Incorporates a 1” BSP stainless steel externally threaded drain connection and cap. The end cap is not removable.

    Ø A(mm) Code

    80mm 107 4111808

    100mm 107 4111810

    130mm 107 4111813

    150mm 107 4111815

    180mm 107 4111818

    200mm 107 4111820

    250mm 107 4111825

    300mm 107 4111830

    350mm 107 4111835

    Horizontal Duct DrainUsed as a drainage connection within an inclined manifold or inclined run. Incorporates a 1” BSP stainless steel externally threaded drain connection and internal dam.

    Ø A(mm) Code

    80mm 132 4110808

    100mm 132 4110810

    130mm 132 4110813

    150mm 132 4110815

    180mm 132 4110818

    200mm 132 4110820

    250mm 132 4110825

    300mm 143 4110830

    350mm 143 4110835

    Vertical In-line DrainUsed either vertically in line or with the Appliance Adaptor. The design helps to divert condensates through an external connection, preventing excessive quantities of condensates from entering back into the appliance. The drain connection is provided with a standard 1” BSP externally threaded pipe to facilitate connection to suitable drainage pipe work.

    Ø Code

    80mm 4119008

    100mm 4119010

    130mm 4119013

    150mm 4119015

    180mm 4119018

    200mm 4119020

    250mm 4119025

    300mm 4119030

    350mm 4119035

    1”BSP

    70m

    m

    70mm

    B

    A

    A

    130m

    m

    16

  • www.powrmatic.ie

    Support ComponentsSupra Plus

    Support LengthThe Support Length can serve two applications, firstly allowing a SUPRA Plus liner to be lowered down a chimney and secondly as a Support Length when used with the Support Plate (with collar removed).

    When used to lower a liner down an existing chimney, All the lugs on the Support Length must be used. The maximum length of product that can be supported by the component is 30 metres.

    Ø Code80mm 4110408

    100mm 4110410130mm 4110413150mm 4110415180mm 4110418200mm 4110420250mm 4110425300mm 4110430350mm 4110435

    Bracing BracketUsed to provide lateral stability back to a support structure. This component must only be used with rigid stays and can be fitted anywhere on the pipe other than between the swages. Structural calculations must be made for each application. Rigid stays must be connected to the three fixing points of this three part component. The hole diameters for the M6 nuts and bolts are 7mm. Constructed from stainless steel.

    Ø I.D. (mm) Code80mm 82 4069208

    100mm 102 4069210130mm 132 4069213150mm 152 4069215180mm 182 4069218200mm 202 4069220250mm 252 4069225300mm 302 4069230350mm 352 4069235

    Support PlateConsists of a stainless steel plate with a three part support collar. The collar rests on the plate and is located under the bead/swage at a joint between components. The three fixing points of the collar rest on the plate, the hole in which being large enough to permit the passage of the swages of the SUPRA Plus construction.The plate must be adequately supported and secured to an adjacent structure. This component can also be used in conjunction with a Support Length, but the collar would be discarded for this application.

    A support must always be used above an Adjustable Length where applied in a vertical application, or where the Adjustable Length would be otherwise liable to load. The maximum length which can be supported by this component is 30 metres.

    Ø Code80mm 4051108

    100mm 4051110130mm 4051113150mm 4051115180mm 4051118200mm 4051120250mm 4051125300mm 4051130350mm 4051135

    Wall Support BracketThis wall band incorporates additional side support struts which can be located below or above the band. In either case the band is located under the bead/swage at a joint between the components. Provides 50mm clearance from the wall. The maximum length which can be supported by this component is 30 metres. Constructed from stainless steel.

    Ø A B C Code80mm 91 114 63.5 4051208

    100mm 104 124 83.5 4051210130mm 118 158 92 4051213150mm 128 168 112 4051215180mm 143 183 142 4051218200mm 153 193 162 4051220250mm 178 218 212 4051225300mm 202 252 266 4051230350mm 227 277 316 4051235

    208m

    m

    A

    B

    C

    17

  • Support ComponentsSupra Plus

    Wall BandTo be used at intervals not exceeding 2.5 metres to provide lateral stability for both vertical and horizontal applications within the system. Manufactured from stainless steel and suitable for both internal and external applications. Provides 50mm clearance from the wall. Maximum free-standing height above last support is 1.5m.

    Ø A(mm) Code80mm 63.5 3115084

    100mm 83.5 3115104130mm 92 3115134150mm 112 3115154180mm 142 3115185200mm 162 3115205250mm 212 3115255300mm 266 3115305350mm 316 3115355

    Adjustable Split BandOffers support to the chimney system when suspending from the ceiling. The Split Band has adjustable brackets to allow the support of angled inclines runs. Designed for use with M10 Drop Rods.

    Ø Code80mm 3123008

    100mm 3123100130mm 3123130150mm 3123150180mm 3123180200mm 3123200250mm 3123250300mm 3123300350mm 3123350

    Location BandThis component consists of a strap which must be secured underneath a joint. It has four equally located stainless steel “spokes” designed to centrally locate and brace the system when lowered into an existing chimney or shaft, and should be used at intervals not exceeding 3 metres. Bespoke Location Bands can be manufactured to order.

    Ø A(mm) Code

    80mm 340 4117108

    100mm 375 4117110

    130mm 390 4117113

    150mm 410 4117115

    180mm 540 4117118

    200mm 560 4117120

    250mm 610 4117125

    300mm 660 4117130

    350mm 850 4117135

    130mm-350mm

    80mm-100mm

    AncillariesSupra Plus

    Replacement SealsThe replacement seals are only suitable for use with the Supra Plus product. Please refer to page 16 for installation instructions on remov-ing and installing replacement seals. Seals are classed as sacrificial and therefore covered by a 12 month manufacturing defects warranty.

    Ø Code80mm 4006308

    100mm 4006310130mm 4006313150mm 4006315180mm 4006318200mm 4006320250mm 4006325300mm 4006330350mm 4006335

    Sprung Locking Band Used for the general assembly of the Supra Plus product. Features a simple sprung toggle locking device for ease of installation on site requiring no additional tooling.

    Ø Code80mm 4117308

    100mm 4117310130mm 4117313150mm 4117315180mm 4117328200mm 4117320250mm 4117325300mm 4117330350mm 4117335

    Bolted Locking BandUsed mainly where additional bracing and strength is required at the joint, such as when installing offsets etc. This band features a lever toggle and adjustable setscrew to allow greater clamping pressure to be exerted on the joint.

    Ø Code80mm 4117008

    100mm 4117010130mm 4117013150mm 4117015180mm 4117028200mm 4117020250mm 4117025300mm 4117030350mm 4117035

    A

    A

    A

    www.powrmatic.ie18

  • TerminalsSupra Plus

    Gas TerminalA terminal designed for use where SUPRA Plus serves conventional gas fired equipment. Incorporates a bird screen/mesh. For condensing and positive pressure applications, a Tapered Top Stub with Mesh is recommended.

    Ø B(mm) A(mm) Code

    80mm 90 210 4116108

    100mm 90 210 4116110

    130mm 115 235 4116113

    150mm 115 235 4116115

    180mm 220 293 4116118

    200mm 220 320 4116120

    250mm 198 365 4116125

    300mm 234 416 4116130

    350mm 288 468 4116135

    Tapered Top StubThis terminal offers least minimal resistance to the evacuation of flue gases and helps to minimise the effects of pluming through slightly increasing the velocity.

    Ø A(mm) B(mm) Code

    80mm 70 241 4115808

    100mm 90 241 4115810

    130mm 120 241 4115813

    150mm 140 241 4115815

    180mm 170 241 4115818

    200mm 190 241 4115820

    250mm 240 241 4115825

    300mm 290 241 4115830

    350mm 340 241 4115835

    Tapered Top Stub with MeshØ A(mm) B(mm) Code

    80mm 70 241 4116008

    100mm 90 241 4116010

    130mm 120 241 4116013

    150mm 140 241 4116015

    180mm 170 241 4116018

    200mm 190 241 4116020

    250mm 240 241 4116025

    300mm 290 241 4116030

    350mm 340 241 4116035

    Parallel Top Stub and MeshSuitable for gas condensing appliances. Parallel flow to minimise back pressure on appliance and maintain system velocity. Fitted with 10mm welded stainless steel mesh.

    Ø A(mm) Code

    80mm 50 4155408

    100mm 50 4155410

    130mm 50 4155413

    150mm 50 4155415

    180mm 50 4155418

    200mm 50 4155420

    250mm 50 4155425

    300mm 50 4155430

    350mm 50 4155435

    Rain CapThis is a basic terminal that offers a degree of protection against rainwater ingress. Not suitable for gas appliances.

    Ø A (mm) B(mm) Code

    80mm 200 183 4155208

    100mm 200 186 4155210

    130mm 255 174 4155213

    150mm 305 221 4155215

    180mm 365 221 4155218

    200mm 406 264 4155220

    250mm 507 276 4155225

    300mm 614 354 4155230

    350mm 716 419 4155235

    A

    A

    A

    A

    A

    B

    B

    B

    B

    www.powrmatic.ie19

  • Elastomer Seal (P1 / W Applications)The Elastomer Seal is located in the recess of the female end of the Supra chimney system as detailed in Fig 1. Where Supra is being used for condensing (WET) / positive pressure (P1) applications up to 200Pa at a maximum flue gas temperature of 200°C, Elastomer Seals MUST be fitted at each joint within the system.Note: Joint Seals are only suitable for gas and 28Sec (Kerosene) applications within the above limits. Where Elastomer Seals are being used, the chimney system must be installed with a minimum of 3° or preferably 5° incline to the horizontal to ensure adequate back drainage of condensation. Failure to maintain an adequate incline and lack of drainage component in the system may lead to premature failure of the product / seals.

    Seal Size Code Number400mm 4006340500mm 4006350600mm 4006360

    Seal lubricant (P1/W))This must be applied around the circumference of the fitted seal to provide a lubricated interface between the seal and the liner when the product is used for positive pressure and wet applications.

    Code NumberSeal Lubricant (250ml) 3107500

    Only SFL lubricant should be used as it has been specially formulated for use with both silicone and EPDM seal materials. Failure to use SFL lubricant when installing seals in Supra product may invalidate the product warranty.

    Sprung Locking BandThis component must be used on every joint be-tween components. Needs to be ordered separately.

    Size Code Number400mm 4027040500mm 4027050600mm 4027060

    Straight Length

    Installed Legnth (mm)

    80mm- 150mm 988 458 193180mm- 600mm 969 459 204

    Lengths

    Code Number4020140 4020240 40203404020150 4020250 40203504020160 4020260 4020360

    Inspection LengthDesigned to be installed within the system to allow access for inspection and cleaning. The door closes on an elastomer seal to provide a water and pressure resistant joint and must only be used where the flue gas temperature will NOT exceed 200°C. For high temperature applications both the inner and outer door seal must be removed prior to installation.

    Size Code No. A B

    400mm 4021040 289 170500mm 4021050 289 170600mm 4021060 289 170

    Adjustable LengthDesigned to be used to make up a required length between two components. It should be used with a standard length which MUST be ordered separately. It can also be inserted into the female end of other components, but however applied, must engage a depth equivalent to at least half the diameter of the Supra being used. Adjustable Length (80mm - 350mm) are also supplied with a special Locking Band and Seal which must be used for condensing applications. For sizes above 350mm, the A Locking Band and Seal MUST be ordered separately.

    Size Code Number400mm 4024440500mm 4024450600mm 4024460

    Adjustable Locking Band and Seal (400mm - 600mm Supra)Required for above sizes when used on wet / positive pressure systems.

    Size Code Number400mm 4007240500mm 4007250600mm 4007260

    AncillariesSupra 1mm

    LengthsSupra 1mm

    AB

    www.powrmatic.ie

    Supra 1mm not stocked, contact us for lead time and price.

    20

  • TeesSupra 1mm

    90° TeeUsed to provide a 90° connection in a system run or can be used as an access / inspection point when used with a Locking Plug

    Size Code No. A B C

    400mm 4020540 969 466 303

    500mm 4020550 969 466 303

    600mm 4020560 969 466 477

    95° Equal TeeThe tee is provided with a 5° connection on the branch to allow for condensate drainage. Can be used at the base of a vertical stack or to facilitate a 5° incline.

    Size Code No. A B C

    400mm 4021940 969 466 303

    500mm 4021950 969 466 303

    600mm 4021960 969 466 477

    135° Equal TeeUsed to provide a 45° connection in a system run or as the entry point to a chimney. Can be used as an access / inspection point when used with a Locking Plug or as a drain when fitted with a Condensate Collector.

    Size Code No. A B C

    400mm 4022240 969 679 521

    500mm 4022250 969 730 642

    600mm 4022260 969 780 762

    135° Tee and 45° Elbow configurationUsed to provide a 90° connection in a system run or can be used as an access / inspection point when used with a Locking Plug

    Size E G

    400mm 783 632

    500mm 832 753

    600mm 881 872

    Locking PlugUsed to close off the branch or base of a tee or the end of a header/manifold. Held in position with a Locking band.

    Size Code Number A

    400mm 4024940 77

    500mm 4024950 77

    600mm 4024960 77

    Condensate CollectorUsed at the bottom of a vertical run, usually under a Tee, to facilitate drainage of condensates from the system. The component includes a stainless steel BSP connection to allow drainage pipework to be connected by others.

    Size Code Number A B400mm 4024340 77 2”500mm 4024350 77 2”600mm 4024360 77 2”

    Offset Condensate CollectorAs above but with drain on rim.

    Size Code Number A B400mm 4026940 77 2”500mm 4026950 77 2”600mm 4026960 77 2”

    Horizontal Duct DrainUsed as a drainage point on the end of an inclined manifold or inclined run. Incorporates an internal condensate dam and BSP stainless steel connection for condensate drainage. Also supplied with fixed end cap. Note: The Cap cannot be removed.

    With CapSize Code No. A

    400mm 4021840 200500mm 4021850 200600mm 4021860 200

    Without CapSize Code No. A

    400mm 4020840 200500mm 4020850 200600mm 4020860 200

    Tee ComponentsSupra 1mm

    77mm

    2”BSP

    77m

    m

    C

    A

    B

    C

    A

    B

    C

    E

    G

    A

    B

    77mm

    2”BSP

    A

    www.powrmatic.ie21

  • ElbowsSupra 1mm

    15° ElbowUsed to provide a 15° change of direction from the vertical.

    Size Code No. A B

    400mm 4022540 31 197

    500mm 4022550 33 211

    600mm 4022560 34 224

    30° ElbowUsed to provide a 30° change of direction from the vertical.

    Size Code No. A B

    400mm 4022440 74 237

    500mm 4022450 80 262

    600mm 4022460 87 286

    40° ElbowUsed to provide a 40° change of direction from the vertical.

    Size Code No. A B

    400mm 4029840 113 274

    500mm 4029850 127 311

    600mm 4029860 139 346

    45° ElbowUsed to provide a 45° change of direction from the vertical.

    Size Code No. A B

    400mm 4022340 124 263

    500mm 4022350 139 299

    600mm 4022360 153 333

    85° ElbowUsed to provide a 85° change of direction from the vertical. Also for use on condensing systems to allow a 5° incline to aid drainage of condensate back through the system.

    Size Code No. A B400mm 4022740 343 338500mm 4022750 388 386600mm 4022760 434 437

    87° ElbowUsed to provide a 87° change of direction from the vertical. Also for use on condensing systems to allow a 3° incline to aid drainage of condensate back through the system where headroom is minimal. No standard code-made as a special.

    Size Code No. A B400mm

    N/A - Price on application500mm600mm

    90° ElbowUsed to provide a 90° change of direction from the vertical.

    Size Code No. A B

    400mm 4022840 357 320

    500mm 4022850 405 368

    600mm 4022860 452 415

    A

    B

    A

    B

    A

    B

    A

    B

    B

    A

    B

    A

    B

    A

    www.powrmatic.ie22

  • AdaptorsSupra 1mm

    Appliance AdaptorUsed to connect the Supra product to the appliance. The interface between the Adaptor and the appliance outlet should be sealed with silicon sealant when used on condensing appliances.

    Size Code No. A B

    400mm 4029340 42 197500mm 4029350 42 197600mm 4029360 42 197

    Appliance Adaptor with Condense TrapUsed to connect the Supra product to the appliance and drain condensate from the system where used on high efficiency and condensing appliances. The interface between the Adaptor and the appliance outlet should be sealed with silicon sealant. The design helps divert condensates through a 15mm OD stainless steel tube to which a drain hose can be connected, prior to entering the appliance.

    Size Code No. A

    400mm 4021440 130

    500mm 4021450 130

    600mm 4021460 130

    TerminalsSupra 1mm

    Tapered Top StubThis terminal offers least resistance to the evacuation of flue gases and should only be used in accordance with the regulations.

    SizeDimensions

    Code NumberA B

    400mm 350 228 4025840500mm 400 228 4025850600mm 500 228 4025860

    Tapered Top Stub with MeshThis terminal should be used with gas condensing appliances as it offers least resistance to flow and help minimise the effects of pluming.

    SizeDimensions

    Code NumberA B

    400mm 350 228 4026040500mm 400 228 4026050600mm 500 228 4026060

    Rain CapThis is a basic terminal that offers a de-gree of protection against rain ingress

    Size Code Number400mm 4055240500mm 4055250600mm 4055260

    Gas TerminalA terminal designed for use where Supra serves conventional gas fired equipment. Incorporates a bird screen/mesh. For condensing and positive pressure applications it is suggested to use a Tapered Top Stub with Mesh.

    SizeDimensions

    Code NumberA B

    400mm 519 418 4006140500mm 623 526 4006150600mm 720 634 4006160

    B

    A

    Flue Size

    A

    A

    B

    A

    B

    A

    B

    B

    A

    www.powrmatic.iewww.powrmatic.ie23

  • Support ComponentsSupra 1mm

    Bracing BracketUsed to provide lateral stability back to sup-port structure. This component must only be used with rigid stays and can be fitted any-where on the pipe other than between the swages. Structural calculations must be made for each application. Rigid stays must be con-nected to the three fixing points of this three part component. The hole diameters for the M6 nuts and bolts are 7mm. Constructed from stainless steel.

    Size Code Number400mm 4069240

    500mm 4069250

    600mm 4069260

    Support PlateConsists of a stainless steel plate with a three part support collar. The collar rests on the plate and is located under the bead/swage at a joint between components. The three fixing points of the collar rest on the plate, the hole in which being large enough to permit the passage of the swages of the Supra construction.The plate must be adequately supported and secured to an adjacent structure. This component can also be used in conjunction with a Support Length, but the collar would be discarded for this application.This component or a Wall Support MUST ALWAYS be used above an Adjustable Length where applied in a vertical application, or where the Adjustable Length would be otherwise liable to load. The maximum length which can be supported by this component is 30 metres.

    Size Code Number

    400mm 4051140

    500mm 4051150

    600mm 4051160

    Wall BandTo be used at intervals not exceeding 2.5 metres to provide lateral stability for both vertical and horizontal applications within the system. Manufactured from stainless steel and suitable for both internal and external applications.

    Size A Code Number80mm 63.5 3115084

    100mm 83.5 3115104130mm 92 3115134150mm 112 3115154180mm 142 3115185200mm 162 3115205250mm 212 3115255300mm 266 3115305350mm 316 3115355400mm 366 3115405500mm 467 3115505600mm 567 3115605

    Support LengthThe Support Length can serve two applications, firstly allowing a Supra liner to be lowered down a chimney and secondly as a Support Length when used with the Support Plate (less the collar).In all cases, ALL the lugs on the Support Length MUST be used when lowering the product. The maximum length of product that can be supported by the component is 30 metres.

    Size Code Number400mm 4020440500mm 4020450600mm 4020460

    Location BandThis component consists of a strap which must be secured underneath a joint. It has four equally located stainless steel “spokes” designed to centrally locate and brace the system where lowered into an existing chimney or shaft, and should be used at intervals not exceeding 3 metres. Constructed from stainless steel.Bespoke Location Bands to facilitate non-standard shafts can be manufactured to order. Please refer to SFL Technical Department with your requirement.

    Size A Code Number400mm 900 4017140

    500mm 1000 4017150

    600mm 1100 4017160

    130mm-350mmA

    A

    www.powrmatic.ie24

  • LengthsNova

    Straight LengthAvailable in nominal installed lengths of 1500mm, 1000mm, 500mm, 250mm & 120mm.

    ø 120mm Code 250mm Code 500mm Code 1000mm Code

    100mm 4575304N 4571904N 4575104N 4575004N130mm 4575305N 4571905N 4575105N 4575005N150mm 4575306N 4571906N 4575106N 4575006N180mm 4575307N 4571907N 4575107N 4575007N200mm 4575308N 4571908N 4575108N 4575008N250mm 4575310N 4571910N 4575110N 4575010N304mm 4575312N 4571912N 4575112N 4575012N355mm 4575314N 4571914N 4575114N 4575014N

    1500mm Code

    150mm 4579906N

    Adjustable LengthThe adjustable length offers a degree of flexibility when standard length dimensions are not suitable. All adjustable lengths are supplied with separate insulating material for insertion into the annulus once the installed length has been determined. As the insulation density is installed on site and not controlled by SFL, we would recommend that this component is located at least 300mm from any combustible material.

    Type Short (210mm - 320mm) Long (310mm - 500mm)

    ø Code Code Seal100mm 4576604N 4574604N 4006310130mm 4576605N 4574605N 4006313150mm 4576606N 4574606N 4006315180mm 4576607N 4574607N 4006318200mm 4576608N 4574608N 4006320250mm 4576610N 4574610N 4006325

    Short (255mm - 410mm) Long (330mm - 550mm)304mm 4576612N 4574612N 4006530355mm 4576614N 4574614N 4006535

    Where Adjustable Lengths are required for positive pressure and condensate resistance, two seals are required per component.

    Tapered Adaptor LengthDesigned to offer an aesthetic transition from the appliance outlet or connecting flue pipe tothe NOVA chimney system.

    ø A (mm) O.D Code

    130mm 125mm 4570405N150mm 150mm 4570406N180mm 175mm 4570407N200mm 200mm 4570408N

    To order NOVA® in satin black factory-finish, add a “B” to the end of the part number. e.g. for 150ID starter length, use part number 4570406NBThese are made to order. Enquire to customer services for lead times.

    996m

    m

    150m

    mM

    IN

    MAX

    www.powrmatic.ie25

  • LengthsNova

    Adjustable Slip LengthAn alternative to conventional adustable lengths, this component consists of a length which will fit inside an existing chimney length and a cover jacket to be insulated by the installer with the insulation provided.

    A distance of 300mm to combustible materials should be observed when installing this component.

    N.B. This component does not form a complete length of twin-wall chimney (as do our regular adjustable lengths) and requires a standard straight length of the same diameter.

    ø Code

    100mm 4570004N130mm 4570005N150mm 4570006N180mm 4570007N200mm 4570008N250mm 4570010N

    Inspection Length – (N1/D)Use to provide access for inspection or cleaning via an insulated lockable door. This component is only suitable for negative pressure/dry non-condensing applications. For positive pressure or wet condensing applications use the P1/W inspection length.

    ø Code100mm N/A130mm 4576205N150mm 4576206N180mm 4576207N200mm 4576208N250mm 4576210N304mm 4576212N355mm 4576214N

    Inspection Length – (P1/W)Use to provide access for inspection and cleaning. To be used for positive pressure and wet systems where the flue gases are likely to condensate within the chimney system. Suitable for flue gas temperatures up to 200°C at 200Pa.

    Dims (mm)

    ø A B Code

    100mm 206 70 4576304N130mm 206 80 4576305N150mm 215 100 4576306N180mm 215 100 4576307N200mm 215 100 4576308N250mm 215 100 4576310N304mm 215 100 4576312N355mm 215 100 4576314N

    B

    A

    500m

    m

    Duct Drain LengthUsed in an inclined position to trap condensate and permit drainage. It is fitted with a standard stainless steel BSP thread connection and incorporates an internal back flow dam.

    ø Dim A Code

    100mm 150 4576804N130mm 150 4576805N150mm 150 4576806N180mm 150 4576807N200mm 150 4576808N250mm 150 4576810N304mm 150 4576812N355mm 150 4576814N

    Probe LengthSupplied with a M16 threaded washer and bolt to facilitate a commissioning sampling probe. Cover jacket supplied to cover sampling point when not in use.

    100mm 4576704N130mm 4576705N150mm 4576706N180mm 4576707N200mm 4576708N250mm 4576710N304mm 4576712N355mm 4576714N

    A B C150mm 100mm 80mm

    Damper Length (P1/W)Use for balancing multi-inlet systems and to add resistance. Also suitable for wet systems.

    ø Code100mm 4574004N130mm 4574005N150mm 4574006N180mm 4574007N200mm 4574008N250mm 4574010N304mm 4574012N355mm 4574014N

    A

    1” BSP

    250m

    m

    A B

    C

    www.powrmatic.ie

    500m

    m

    26

  • ElbowsNova

    2 Segment Elbows (15°, 30°, 40°, 45°)Provides a change of direction, measured from the vertical by the specified angle. See technical data in Nova brochure for dimensions. Elbows are now supplied with an unbarbed female coupler and screw-toggle type locking band.

    Angle ø 15° Code 30° Code 40° Code 45° Code

    100mm 4575404N 4575504N 4575604N 4575704N130mm 4575405N 4575505N 4575605N 4575705N 150mm 4575406N 4575506N 4575606N 4575706N 180mm 4575407N 4575507N 4575607N 4575707N 200mm 4575408N 4575508N 4575608N 4575708N 250mm 4575410N 4575510N 4575610N 4575710N 304mm 4575412N 4575512N 4575612N 4575712N 355mm 4575414N 4575514N 4575614N 4575714N

    Three-segment 90°, 85° & 87° ElbowsProvides a change of direction measured from the vertical. Use 85° and 87 ° for condensing applications where a 5° or 3° incline (respectively) to the horizontal is required for condensate drainage.

    Angle 85° Dimension (mm) 87° Dimension (mm)

    ø A B C Code A B C Code

    100mm 91 126 192 4575804N 91 126 185 4574904N

    130mm 98 136 207 4575805N 98 136 200 4574905N

    150mm 102 144 217 4575806N 102 144 210 4574906N180mm 108 156 233 4575807N 108 156 226 4574907N200mm 112 165 244 4575808N 112 165 236 4574908N250mm 123 185 270 4575810N 123 185 262 4574910N304mm 132 217 297 4575812N 132 217 291 4574912N355mm 140 235 318 4575814N 140 235 312 4574914N

    Angle 90° Inspection Elbow

    Dimension (mm)

    ø A B C Code

    100mm 91 180 283 4576104N130mm 98 180 290 4576105N

    150mm 102 200 301 4576106N180mm 108 200 307 4576107N200mm 112 200 311 4576108N250mm 123 200 322 4576110N304mm 133 200 332 4576112N355mm 143 200 342 4576114N

    A

    A

    B

    C

    A

    B

    C

    A

    Dimension (mm)

    ø A B C Code

    100mm 91 180 283 4576104N130mm 98 180 290 4576105N150mm 102 200 301 4576106N180mm 108 200 307 4576107N200mm 112 200 311 4576108N250mm 123 200 322 4576110N304mm 133 200 332 4576112N355mm 143 200 342 4576114N

    www.powrmatic.ie27

  • TeesNova

    www.powrmatic.ie

    90° Equal TeeUsed as the entry to a vertical chimney, or for horizontal header configurations.

    Angle 90° Equal Tee

    Angle 90° Dimension (mm)

    ø A B C Code

    100mm 300 180 140 4573004N130mm 330 195 155 4573005N150mm 350 205 165 4573006N180mm 380 220 180 4573007N200mm 400 230 190 4573008N250mm 450 255 215 4573010N304mm 500 265 240 4573012N355mm 550 305 265 4573014N

    Reducing Tees

    Branch ø 90° Code 95° Code

    100mm 4559001 4559501130mm 4559003 4559503150mm 4559011 4559511180mm 4559021 4559521200mm 4559028 4559528250mm 4559034 4559534300mm 4559041 4559541

    90° & 95° Reducing TeeA wide variety of reducing tee combinations are available. Listed here are the most common single-step reductions (i.e. 150mm body, 130mm branch). For a full list of standard reducing tees, please visit www.sflchimneys.com

    Angle 93° Dimension (mm) 95° Dimension (mm)

    ø A B C Code A B C Code

    100mm 300 180 140 4573304N 300 180 140 4576404N 130mm 330 195 155 4573305N 330 195 155 4576405N 150mm 350 205 165 4573306N 350 205 165 4576406N 180mm 380 220 180 4573307N 380 220 180 4576407N 200mm 400 230 190 4573308N 400 230 190 4576408N 250mm 450 255 215 4573310N 450 255 215 4576410N 304mm 500 286 240 4573312N 500 286 240 4576412N 355mm 550 305 270 4573314N 550 305 270 4576414N

    93° & 95° Equal TeeUsed at the base of a vertical chimney, or for horizontal header configurations. Allows for a 3° or 5° (respectively) incline on wet systems to allow for condensate drainage.

    135° TeeUsed at the base of a vertical chimney, or to allow a smooth transition from the horizontal to vertical plain when used with a 45° elbow. The coupler on the branch is unbarbed to allow unlimited rotational adjustment and provided with an adjustable screw-toggle locking band.

    Dimension (mm)With 40° Elbow With 45° Elbow

    ø A B C D C D Code100mm 495 325 385 23 385 31 4576504N130mm 495 340 407 22 407 30 4576505N150mm 495 375 439 29 439 38 4576506N180mm 745 420 481 37 481 47 4576507N200mm 745 450 509 43 509 53 4576508N250mm 745 520 577 55 577 65 4576510N304mm 745 585 625 73 625 84 4576512N

    28

  • Tee ComponentsNova

    Tee CapUsed to close off the branch or base of a tee or for use as an access/inspection component.

    ø A Code100mm 63 4579104N130mm 63 4579105N150mm 63 4579106N180mm 63 4579107N200mm 63 4579108N250mm 63 4579110N304mm 63 4579112N355mm 63 4579114N

    Tee Cap with DrainUsed at the bottom of a vertical chimney to facilitate the drainage of condensate from the system. Fitted with a stainless steel BSP external thread drain connection.

    ø A Code100mm 63 4576904N130mm 63 4576905N150mm 63 4576906N180mm 63 4576907N200mm 63 4576908N250mm 63 4576910N304mm 63 4576912N355mm 63 4576914N

    Draught RegulatorDual action draught regulator suitable for gas, oil and solid fuel applications. Designed to be used with SFL chimney systems where excessive draught is likely to create combustion problems. When used with the NOVA chimney system, the regulator should be applied with the 45785XXN appliance adaptor (in turn located onto the 90° tee branch).

    ø Code100mm 3192004130mm 3192005150mm 3192006180mm 3192007200mm 3192008250mm 3192010304mm 3192012355mm 3192014

    SpecificationDiameter (mm)

    150/180 200/250Classification to DIN 4796 4 4

    Adjustment Range (Pa) 10-33 4-35

    IncreasersNova

    A

    A

    1”BSP

    IncreaserFacilitates an increase in diameter by one step. Constructed with a smooth conical design and welded seams to prevent the build up of condensates

    ø Dim A (mm) Code100mm 130 4573604N130mm 150 4573605N150mm 180 4573606N180mm 200 4573607N200mm 250 4573608N100mm 150 4573704N150mm 200 4573706N

    Eccentric IncreaserDesigned specifically for condensing applications to provide an increase in diameter without pooling of condensation in horizontal or inclined runs.

    ø A Code150mm 200 4570606N180mm 250 4570607N200mm 250 4570608N200mm 304 4570708N250mm 304 4570610N250mm 355 4570710N

    A

    A

    250mm

    Draught Regulator c/w Pressure ReliefIdeal for use on biomass pellet appliances but also suitable for gas and oil fired appliances where the flue gas temperature will not exceed 400°C. The component also includes an explosion/pressure relief mechanism as required by many biomass appliance manufacturers. Supplied with male adaptor.Note: This component is supplied with an un-barbed male coupler to allow the Draught Regulator to be positioned plumb vertical at any angle of flue-run.

    ø Code150mm 4574206N180mm 4574207N200mm 4574208N

    Tee ComponentsNova

    198m

    m

    www.powrmatic.ie29

  • AdaptorsNova

    Appliance AdaptorUsed to connect the appliance outlet to the NOVA® chimney system. This adaptor is also used for connection of the draught regulator to the branch of a 90° tee. Also used to connect NOVA® to Sigma single wall connecting flue pipe.

    ø O.D. Code100mm 98 4578504N130mm 128 4578505N150mm 148 4578506N180mm 178 4578507N200mm 198 4578508N250mm 248 4578510N304mm 298 4578512N355mm 348 4578514N

    Appliance Adaptor (Imperial)Used for connection to appliances with imperial or equivalent spigots.

    ø A O.D. Code130mm 63 125mm 4578405N180mm 63 175mm 4578407N

    Appliance Increaser AdaptorUsed to increase the appliance outlet size by one diameter.

    ø O.D. (A) Code100mm 80mm 4579404N150mm 123mm 4579505N150mm 130mm 4579405N

    NOVA® to Supra+ AdaptorDesigned to facilitate connection from the NOVA® to Supra chimney system.

    ø Code100mm 4179704N130mm 4179705N150mm 4179706N180mm 4179707N200mm 4179708N250mm 4179710N304mm 4179712N355mm 4179714N

    NOVA® to Flex AdaptorUsed to connect the NOVA® product to a flexible flue liner. Supplied with clamp band for ease of installation.

    ø A B Code100mm 113 96 4573404N130mm 138 121 4573405N150mm 163 146 4573406N180mm 190 171 4573407N200mm 213 196 4573408N250mm 263 246 4573410N304mm 313 296 4573412N355mm 363 346 4573414N

    Flex to NOVA® AdaptorUsed to connect a flexible flue liner to NOVA®, e.g. where a masonry chimney has been capped within a roof void. Supplied with clamp band for ease of installation.

    ø A B Code100mm 113 96 4573204N130mm 138 121 4573205N150mm 163 146 4573206N180mm 190 171 4573207N200mm 213 196 4573208N250mm 263 246 4573210N304mm 313 296 4573212N355mm 363 346 4573214N

    Adaptor to Nova (45732XXN)

    Clamp band with screw toggle adjustment

    Flexible chimney liner

    Flex adaptor installation example

    63m

    m

    O.D.

    63m

    m

    O.D.

    113m

    m

    O.D.

    A

    B

    A

    B

    www.powrmatic.ie30

  • Support ComponentsNova

    ø Code100mm 3123150130mm 3123180150mm 3123200180mm 3123230200mm 3123250250mm 3123300304mm 3123350355mm 3123400

    ø A B Code100mm 33 117 4578804N130mm 33 117 4578805N150mm 33 117 4578806N180mm 33 117 4578807N200mm 33 117 4578808N250mm 33 117 4578810N304mm 33 117 4578812N355mm 33 117 4578814N

    AB

    AB

    D

    Roof / Rafter SupportProvided with adjustable and locking gimbal plates to permit a chimney to be supported on roof joists, trussed rafters etc. Maximum suspended chimney length supported is 6.0 metres and maximum total length supported is 9.0 metres.

    ø A B Code

    100mm 418 310 7072610130mm 448 340 7072613150mm 468 360 7072615

    180mm 498 390 7072618

    200mm 518 410 7072620250mm 568 460 7072625304mm 618 510 7072630355mm 668 560 7072635

    Single Wall to NOVA® Anchor PlateDesigned to be used when connecting NOVA® to a lintel or pre-cast chamber. A short section of liner projects a nominal 32mm through the bottom of the plate. Installed length “H” is 40mm while “E” is 27mm and there are 8 x 11mm fixing holes at the centres shown in the table below. Manufactured in stainless steel. Maximum Load: 13m

    For loading details and maximum distance between supports, please see technical section of SFL Nova brochure.

    Universal Split BandOffers lateral support to the chimney system. The split band has adjustable brackets to allow the support of inclined runs. Design for use with M10 Drop Rod.

    ø A B C D Code100mm 281 196 252 40 4577504N130mm 311 226 282 40 4577505N150mm 331 246 302 40 4577506N180mm 360 275 331 40 4577507N200mm 384 299 355 40 4577508N250mm 432 345 403 40 4577510N304mm 482 395 453 40 4577512N355mm 533 446 504 40 4577514N

    Support length (Strut/Guy Attachment)A 117mm installed length which incorporates a plate located 33mm from the bottom edge and features slotted holes for rotational adjustment. This component also doubles as a strut / guy attachment length offering anchoring points to which guys, or preferably rigid stays can be secured using M8 nuts and bolts. Manufactured from stainless steel.

    www.powrmatic.ie31

  • Wall Support BracketUsed to take the vertical load of the chimney when supported from a wall. The support bracket is fully adjustable allowing varying clearances from the wall (50mm as standard). Requires M10 wall fixings.

    ø A B C Stainless Code Galvanised Code100mm 252 281 235 4572304 4572204130mm 282 311 265 4572305 4572205150mm 302 331 285 4572306 4572206180mm 331 360 314 4572307 4572207200mm 355 384 338 4572308 4572208250mm 403 432 384 4572310 4572210304mm 453 482 434 4572312 4572212355mm 504 533 485 4572314 4572214

    Universal Support PlateA support plate designed for use with bespoke bracketry such as Uni-Strut/Niessing or site fabricated. Supplied complete with a Support Length. Fixing hole size 11mm to suit M10 fixings.

    ø A B Max Load Stainless Code Galvanised Code100mm 196 252 13m 4571704N 4571404N130mm 226 282 13m 4571705N 4571405N150mm 246 302 13m 4571706N 4571406N180mm 275 331 13m 4571707N 4571407N200mm 299 355 13m 4571708N 4571408N250mm 345 403 13m 4571710N 4571410N304mm 395 453 13m 4571712N 4571412N355mm 446 504 13m 4571714N 4571414N

    For loading details and maximum distance between supports, please see Nova brochure.

    Support ComponentsNova

    A

    A B

    C

    A

    B

    www.powrmatic.ie

    Dim Galvanised Code Extension (mm) Stainless Code Galvanised Code

    ø A Stainless Min Max

    100mm 112 3115154 3116154 65 105 3119136 3120136

    130mm 142 3115185 3116185 50 100 3119136 3120136

    150mm 162 3115205 3116205 50 100 3119136 3120136

    180mm 192 3115234 3116234 50 100 3119136 3120136

    200mm 212 3115255 3116255 50 100 3119136 3120136

    250mm 266 3115305 3116305 50 100 3119180 3120180

    304mm 316 3115355 3116355 75 140 3119245 3120245

    355mm 366 3115405 3116405 50 120 3119245 3120245

    Wall Band Extension PiecesUsed with Wall Bands, these components allow the clearance between the wall and outer surface of the chimney to be increased. Where externally applied, the intervals between Wall Band fixing centres must be reduced from 4.0 metres to 3.5 metres. The maximum clearance is as detailed below.

    See installation section of SFL Nova brochure for assembly details.

    Wall BandsWall bands provide lateral support for the chimney and must be used at intervals not exceeding 4.0 metres beyod any load bearing support.

    For external applications the stainless steel version must be used.

    32

  • Support ComponentsNova

    Pick & Mix Support SystemAn alternative system to SFL’s conventional support components, designed to offer a flexible solution to the individual support requirements of domestic installations. Available for chimney diameters up to 250mm, each part is ordered separately to comprise the bracket required.

    The Wall Band is designed to offer 50mm clearance from the outer case of the chimney to the back plate of the bracket. Where required, Extension Brackets can be used to increase this distance to within the specified dimensions as detailed within the table below. The bracket must be installed plumb and fixed to the structure using adequate fixings. The Wall Bracket is fitted with two M6 Nut Inserts to allow easy fixing of the two Support Band Rings using the M6 bolts and washers provided.

    Extension Brackets are designed to extend the clearance from the outer case of the chimney to the structure. The Extension Brackets have been designed to slide through on the inside of the Wall band and can be cut to length if required.

    Maximum/minimum distances for wall bands and extension arms:ø Max Max Max Min Min

    100mm 249 320 525 55mm 50mm130mm 234 305 510 55mm 50mm150mm 224 295 500 55mm 50mm180mm 209 280 485 55mm 50mm200mm 199 270 475 55mm 50mm250mm 174 245 450 55mm 50mm

    Bracing Brackets can be attached to the Extension Brackets along with the Support Plate and Universal Split Band to produce a Wall Support for vertical loading.

    Maximum extension Loading

    ø SHORT MEDIUM LONG Max Loading (m)100mm 124 195 400 8.6130mm 94 165 370 7.0150mm 74 145 350 6.2180mm N/A 115 320 5.2200mm N/A 95 300 4.8250mm N/A N/A 250 3.9

    Wall BandCan also be used as a conventional Wall Band

    ø A Code100mm 220 3109510130mm 250 3109513150mm 270 3109515180mm 300 3109518200mm 320 3109520250mm 370 3109525

    Extension BracketsAvailable in Short, Medium and Long versions to provide the required distance from wall

    Size A CodeShort 324 31093ST

    Medium 395 31093MDLong 600 31093LG

    Bracing BracketsAvailable in three sizes to suit Extension Brackets (above).

    Size A (mm) CodeShort 521 31094ST

    Medium 557 31094MDLong 571 31094LG

    Support lengthCan be used with the Support Plate and Bracing Brackets as part of a loadbearing wall support.

    ø Code100mm 4578804N130mm 4578805N150mm 4578806N180mm 4578807N200mm 4578808N250mm 4578810N

    Support PlateFor use with the support length and cantilever framework to create a loadbearing wall support.

    ø A Code100mm 220 3109710130mm 250 3109713150mm 270 3109715180mm 300 3109718200mm 320 3109720250mm 370 3109725

    A

    A

    A

    A

    www.powrmatic.ie33

  • Floor & Ceiling PenetrationNova

    Gas and oil appliance (T250) The following components MUST be used on gas or oil fired appliances where the flue gas temperatures does not exceed 250°C and / or where the chimney passes through a non-combustible floor.

    Ceiling SupportProvides a 50mm air gap clearance to a penetrated floor or ceiling and is only used where NOVA® penetrates a non-combustible floor, and / or services a gas or oil fired appliance where the flue gas temperature does not exceed 250°C

    Firestop SpacerUsed to provide location, fire and dust stopping where NOVA® is used through non-combustible floors, and / or serves a gas or oil fired appliance where the flue gas temperatures does not exceed 250°C. This item does not load bear.

    Dimension (mm) Dimension (mm)

    ø A B Code A B Code100mm 300 250 4502704 300 250 4508704130mm 330 280 4502705 330 280 4508705150mm 355 305 4502706 355 305 4508706180mm 381 331 4502707 381 331 4508707200mm 406 356 4502708 406 356 4508708250mm 457 407 4502710 457 407 4508710304mm 507 457 4502712 507 457 4508712355mm 558 508 4502714 558 508 4508714

    Solid fuel and oil fire appliance (T450)The following components MUST be used where NOVA® is used on solid fuel or oil fired appliances where the flue gas temperature will not exceed 450°C and /or where the chimney system penetrates a combustible floor. Each ventilated component offers a 50mm clearance to combustible materials.

    Standard Ventilated Ceiling Support (T450)Used to both support and firestop the chimney system when it passes through the first combustible floor directly above the appliance. The support component incorporates a patented intumescent matrix design which expands rapidly with temperature and seals the plate to prevent the potential spread of fire or smoke from the room below.

    Ventilated Firestop (T450)Used where the chimney passes through the upper combustible floors and where sections below the floor are enclosed within a non combustible shaft. This item does not load bear.

    Dim (mm) Dim (mm)

    ø A B C Code A B Code100mm 331 251 349 7072710 251 349 5508310130mm 361 281 379 7072713 281 379 5508313150mm 381 301 399 7072715 301 399 5508315180mm 411 331 429 7072718 331 429 5508318200mm 431 351 453 7072720 351 453 5508320250mm 481 401 501 7072725 402 501 5508325304mm 531 451 551 7072730 452 551 5508330

    For painted variations add the following letters after the part number:- White: ZW

    D5 Ventilated Ceiling Support (T450)Used as per the standard version. The D5 offers an aesthetically pleasing flat appearance where the chimney passes through the ceiling penetration and uses minimal ventilation openings. This component is finished in a high quality white wet-sprayed finish.

    ø A B Code100mm 322 249 7072810ZW130mm 352 279 7072813ZW150mm 372 299 7072815ZW180mm 402 329 7072818ZW200mm 422 349 7072820ZW

    B

    A

    A B

    C

    AB

    AB

    www.powrmatic.ie

    Standard Ventilated Ceiling Support (T450)

    Ventilated Firestop (T450)

    Standard Ventilated Ceiling Support (T450) Ventilated Firestop (T450)

    34

  • Ventilated Firestop (T450)

    TerminalsNova

    Top StubThe terminal offers the least resistance to flue gases and is ideal for solid fuel and oil fired appliances, providing there is drainage at the base of the chimney.

    Top Stub With MeshIdeally suited for condensing/high efficiency appliances. Not suitable for solid fuel application or where there is no provision for drainage below termination.

    Dimension (mm) Dimension (mm)

    ø A Code A Code

    100mm 100 4570804 100 4570704130mm 100 4570805 100 4570705150mm 100 4570806 100 4570706180mm 100 4570807 100 4570707200mm 100 4570808 100 4570708250mm 100 4570810 100 4570710304mm 100 4570812 100 4570712355mm 100 4570814 100 4570714

    Rain CapThe Rain Cap offers a degree of protection from rain and is suitable for solid fuel and oil fired appliances.

    Round TopThe Round Top offers a greater degree of protection against driving rain and wind, recommended for exposed locations.

    Dim (mm) Dim (mm)

    ø A B Code A B Code

    100mm 255 192 4577304 255 155 4573104130mm 255 197 4577305 300 159 4573105150mm 300 204 4577306 300 157 4573106180mm 358 265 4577307 358 189 4573107200mm 402 265 4577308 402 194 4573108250mm 500 300 4577310 500 253 4573110304mm 716 345 4577312 716 288 4573112355mm 716 385 4577314 716 356 4573114

    Storm CowlThe Storm Cowl is designed to offer the maximum protection against driving rain and strong winds. Please note that this is not an anti-down draught terminal.

    Storm Cowl with MeshNot suitable for solid fuel applications.

    ø A B Code A B Code

    100mm 270 165 4578704 270 165 4578904130mm 294 165 4578705 294 165 4578905150mm 319 165 4578706 319 165 4578906180mm 344 165 4578707 344 165 4578907200mm 369 165 4578708 369 165 4578908250mm 419 210 4578710 419 210 4578910

    NOVA® Mini EUROCOWLThe NOVA®-specific edition of the most popular anti-downdraught cowl on the market, complete with a factory-fitted NOVA female coupler and locking band for effortless and secure installation.

    ø Code

    150mm 4574506N

    A

    A

    A

    B

    A

    B

    A

    B

    Gas Terminalø A B Code

    100mm 236 118 4552404130mm 236 118 4552405150mm 267 118 4552406180mm 293 220 4552407200mm 320 220 4552408250mm 368 220 4552410304mm 421 220 4552412355mm 469 220 4552414A

    B

    www.powrmatic.ie35

  • AccessoriesNova

    NOVA® Stainless Storm CollarThe NOVA® polished stainless steel storm collar is larger and offers a greater degree of protection from weathering. It also adds a superb looking finish to your installation. Highly recommended to complement the EcoPro flashing.

    ø A B Code100mm 151 350 4504104130mm 181 380 4504105150mm 201 400 4504106180mm 231 400 4504107200mm 251 450 4504108

    Trim CollarThe trim collar is a polished stainless steel circular collar with a nominal 105mm wide circular flange. This item is used to offer an aesthetic closing ring where a chimney passes through an outside wall.

    ø Code100mm 4583204130mm 4583205150mm 4583206180mm 4583207200mm 4583208250mm 4583210304mm 4583212355mm 4583214

    45° Wall SleevesMust be used where a 135° tee is used to pass the chimney through an external wall and thus providing a continuous interrupted run through the wall. Provides 50mm clearance as standard. Although designed to suit a 280mm maximum width wall, special sizes can be manufactured to order.

    ø A Code100mm 250 3107204130mm 280 3107205150mm 300 3107206180mm 330 3107207200mm 350 3107208250mm 400 3107210304mm 450 3107212355mm 500 3107214

    Seal LubricantThis must be applied around the circumference of the fitted seal to provide a lubricated interface between the seal and the liner when the product is used for positive pressure and wet applications.

    Code250ml 3107500

    Only SFL lubricant should be used as it has been specially formulated for use with both silicone and EPDM seal materials. Failure to use SFL lubricant when installing seals in NOVA product will invalidate the product warranty and potentially cause failure of the seal.

    A

    B

    Sprung Locking BandThe locking band must be used on all joints and are included with each component having a female coupler.

    ø Code100mm 4578604130mm 4578605150mm 4578606180mm 4578607200mm 4578608250mm 4578610304mm 4578612355mm 4578614

    Bolted Locking BandThe screw-toggle locking band is provided as standard with the unbarbed female coupler on elbows and 135° tee branches.

    ø Code100mm 4578604MT130mm 4578605MT150mm 4578606MT180mm 4578607MT200mm 4578608MT250mm 4578610MT304mm 4578612MT355mm 4578614MT

    Joint Sealing Ring (W/P1)

    ø Code100mm 4006310130mm 4006313150mm 4006315180mm 4006318200mm 4006320250mm 4006325304mm 4006430355mm 4006435

    Joint Sealing Ring (W/P1) for 305mm and 355mm Adjustable Lengths ONLY

    ø Code304mm 4006530355mm 4006535

    A

    www.powrmatic.ie36

  • ComponentsNova

    Angled Wall Cover RingThe wall cover ring is designed to offer an aesthetic trim around the chimney where it penetrates a wall at an angle. This component is available in five angle variations, 0°-10°, 10°-20°, 20°- 30°, 30°-40° and 40°- 50°.

    Wall Penetration Angle

    ø A 0°-10° Code 10°-20° Code 20°-30° Code 30°-40° Code 40°-50° Code130mm 156 5571213N 5571313N 5570013N 5570313N 5570213N150mm 146 5571215N 5571315N 5570015N 5570315N 5570215N180mm 131 5571218N 5571318N 5570018N 5570318N 5570218N200mm 121 5571220N 5571320N 5570020N 5570320N 5570220N

    Intumescent SealantRequired for the correct installation of the Ventilated Ceiling Support & the D5 firestop.

    Code290ml 0199900

    www.powrmatic.ie37

  • Lengths and ComponentsNova Commercial

    Straight LengthsStraight lengths are available in nominal in-stalled lengths of 1000mm, 500mm and 250mm.

    SizeCode Numbers

    1000mm 500mm 250mm

    400mm 4575016N 4575116N 4571916N

    450mm 4575018N 4575118N 4571918N

    500mm 4575020N 4575120N 4571920N

    550mm 4575022N 4575122N 4571922N

    600mm 4575024N 4575124N 4571924N

    Inspection LengthUsed to provide access for cleaning and inspection. For pressure and wet applications both the inner and outer door seals MUST be fitted to the product.

    SizeDimensions

    CodeA B

    400mm 100 200 4576316N

    450mm 100 200 4576318N

    500mm 100 200 4576320N

    550mm 100 200 4576322N

    600mm 100 200 4576324N

    Adjustable Slip SectionThe Adjustable Length offers a degree of flexibility when standard dimensions are not suitable. The Adjustable Length is 505mm long and is designed to slide over an existing standard length and must be engage by at least half the diameter of the product being installed. Adjustable Lengths are supplied with separate insulating material for insertion into the annulus once the installed length has been determined.For positive pressure and wet applications a seal must be fitted to the liner of the product in accordance with the installation instructions - See SFL Nova brochure.

    Size Code

    400mm 4576616N

    450mm 4576618N

    500mm 4576620N

    550mm 4576622N

    600mm 4576624N

    Intumescent SealantRequired for the correct installation of the Ventilated Ceiling Support & the D5 firestop.

    Code290ml 0199900

    Horizontal Duct DrainUsed in horizontal or inclined positions to trap condensation and permit drainage from the system. It is fitted with a standard stainless steel BSP threaded connection.

    Size A Code400mm 2” BSP 4576816N450mm 2” BSP 4576818N500mm 2” BSP 4576820N550mm 2” BSP 4576822N600mm 2” BSP 4576824N

    Probe LengthSupplied with a M16 threaded washer and bolt to facilitate a commissioning sampling probe. Cover jacket supplied to cover sampling point when not in use.

    ø Code100mm 4576704N130mm 4576705N150mm 4576706N180mm 4576707N200mm 4576708N250mm 4576710N304mm 4576712N355mm 4576714N

    A

    B

    MINM

    AX

    A BC

    2”BSP

    www.powrmatic.ie38

  • Tee ComponentsNova Commercial

    Tee Cap with DrainUsed at the bottom of a vertical chimney to facilitate the drainage of condensation from the system. All sizes are fitted with a 2” BSP stainless steel drain boss.

    Size A Code400mm 50 4576916N450mm 50 4576918N500mm 50 4576920N550mm 50 4576922N600mm 50 4576924N

    Tee CapUsed to close off the branch or base of a Tee.

    Size A Code400mm 50 4579116N450mm 50 4579118N500mm 50 4579120N550mm 50 4579122N600mm 50 4579124N

    Draught RegulatorDuel action draught regulator suitable for gas and oil fired appliances. Designed to be used with SFL chimney systems where excessive draught is likely to create combustion problems. Where used with the Nova chimney system, the regulator should be applied with the 45794XX Appliance Adaptor, where XX relates to the diameter and located into the branch of a 90° Tee.

    Size Code400mm 3192016

    The following components MUST be used on gas or oil fired appliances where the flue gas temperatures do not exceed 250°C.

    Provides a 50mm air gap clearance to a penetrated floor or ceiling and is only used where the Nova product penetrates a non-combustible floor, and/or services a gas or oil fired appliance where the flue gas temperatures do not exceed 250°C.

    SizeDimensions

    CodeA B

    400mm 605 555 4502716450mm 655 605 4502718500mm 711 661 4502720550mm 762 712 4502722600mm 813 763 4502724

    Firestop SpacerUsed to provide location, fire and dust stopping where Nova is used through non-combustible floors, and / or serves a gas or oil fired appliance where the flue gas temperatures do not exceed 250°C. This item is non-loadbearing.

    SizeDimensions

    CodeA B

    400mm 605 555 4508716450mm 655 605 4508718500mm 711 661 4508720550mm 762 712 4508722600mm 813 763 4508724

    Floor PenetrationNova Commercial

    A

    A

    2”BSP

    B

    A

    A B

    www.powrmatic.ie39

  • Support ComponentsNova Commercial

    Support Length / Guy BracketA 117mm installed length which incorporates a support plate located 33mm from the bottom edge and features slotted holes for rotational adjustment. For use with the Universal Support Plate or as a Support Length for bespoke bracketry. This component also doubles as a strut / guy attachment length offering anchoring points to which guys, or preferably rigid stays can be secured using M8 nuts and bolts. Manufactured from stainless steel.

    Size Code400mm 4578816N450mm 4578818N500mm 4578820N550mm 4578822N600mm 4578824N

    Wall Support BracketUsed to take the vertical load of the chimney when supported from a wall. The Support is fully adjustable allow-ing varying clearances from the wall (50mm as standard). Requires M10 wall fixings. Supplied complete with Support Length and fixings.

    SizeDimensions

    A B C400mm 551 580 528

    450mm 602 631 579500mm 651 680 628550mm 702 731 679600mm 751 780 728

    SizeCode

    Stainless Galvanised400mm 4572316 4572216450mm 4572318 4572218500mm 4572320 4572220550mm 4572322 4572222600mm 4572324 4572224

    Wall BandsWall Bands provide lateral support for the chimney and must be used at intervals not exceeding 4.0 metres above any load bearing support. For external applications it is rec-ommended that the stainless steel version is used.

    Size A (mm)Code

    Stainless Galvanised400mm 417 3115455 3116455450mm 467 3115505 3116505500mm 517 3115555 3116555550mm 567 3115605 3116605600mm 617 3115655 3116655

    Support Pl