8812 Frey Road, Houston, TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected] FLUORESCENT HIGH BAY T8 SURFACE MOUNT FEATURES • Instant restrike • Uplight option • No color shift • 480 Volt option • Extended lamp life • Improved uniform illumination • Lower component replacement cost • Dimming, occupancy sensor and emergency options available • Improved lumen maintenance ORdER LOGIC PROJECT INFORMATION Project Name Catalog # Type Date AppLICATION • Efficient fluorescent T8 alternative to existing surface mount High Bay lighting. • Suitable for industrial, institutional gymnasiums and warehousing. CONSTRUCTION • Body is code gauge aluminum painted white. • End caps are riveted to body for strength and rigidity. • Optics are high reflectance code gauge aluminum. • No tools required for ballast access. • Lens options available for various shielding requirements. ELECTRICAL • Quality name brand Class P, HPF electronic ballasts. • Camlock lampholders. • U.L. listed damp location. Note: Lens option not available for 5 and 6 lamped versions in ambient temperatures exceeding 55C. 4 - 4 ft. 4 32 FHS N X X X X 04 05 06 Length # Lamps M - Enhanced alum. W - White alum. Reflector Material W1 - Wire guard 11ga. L1 - Lens Prismatic, STD steel door frame L2 - Lens clear, STD steel door frame L4 - Lens clear, HD sealed door frame L5 - V-bottom lens, STD steel door frame XX - None Shielding 3 - (1) F32, 90 min. 8 - (1) or (2) F32, 90 min. X - None Emergency Battery Backup C - Charcoal filter L - Lamps installed S - Sealed body 48G - 480v Transformer Special Options UIN - Multi-volt 120-277 Instant start, Normal BF UIH - Multi-volt 120-277 Instant start, High BF Ballast X 022 - (2) 2 lamp 004 - (1) 4 lamp 023 - (1) 2 lamp, (1) 3 lamp 033 - (2) 3 lamp 024 - (1) 2 lamp, (1) 4 lamp 222 - (3) 2 lamp Ballast Configuration CUT SHEET: FLUORESCENT HIGH BAY T8 SURFACE MOUNT 24” 4”

Upload: crystal-pettibone

Post on 28-Jan-2016

215 views

Category:

Documents


0 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Fluorescent High Bay T8 Surface Mount

8812 Frey Road, Houston, TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected]

FLUORESCENT HIGH BAY T8 SURFACE MOUNT

FEATURES

• Instantrestrike

• Uplightoption

• Nocolorshift

• 480Voltoption

• Extendedlamplife

• Improveduniformillumination

• Lowercomponentreplacementcost

• Dimming,occupancysensorand emergencyoptionsavailable

• Improvedlumenmaintenance

ORdER LOGIC

Project InformatIon

Project Name

Catalog #

Type

Date

AppLICATION • EfficientfluorescentT8alternativeto existingsurfacemountHighBaylighting.

• Suitableforindustrial,institutional gymnasiumsandwarehousing.

CONSTRUCTION • Bodyiscodegaugealuminumpaintedwhite.

• Endcapsarerivetedtobodyforstrength andrigidity.

• Opticsarehighreflectancecodegauge aluminum.

• Notoolsrequiredforballastaccess.

• Lensoptionsavailableforvariousshielding requirements.

ELECTRICAL • QualitynamebrandClassP,HPFelectronic ballasts.

• Camlocklampholders.

• U.L.listeddamplocation.

Note:Lensoptionnotavailablefor5and6lampedversionsinambienttemperaturesexceeding55C.

4 - 4 ft.

4 32FHS N X X X X

040506

Length # Lamps

M - Enhanced alum.W - White alum.

Reflector Material

W1 - Wire guard 11ga.L1 - Lens Prismatic, STD steel door frameL2 - Lens clear, STD steel door frameL4 - Lens clear, HD sealed door frameL5 - V-bottom lens, STD steel door frameXX - None

Shielding

3 - (1) F32, 90 min.8 - (1) or (2) F32, 90 min.X - None

Emergency Battery Backup

C - Charcoal filterL - Lamps installedS - Sealed body48G - 480v Transformer

Special Options

UIN - Multi-volt 120-277Instant start, Normal BFUIH - Multi-volt 120-277Instant start, High BF

Ballast

X

022 - (2) 2 lamp004 - (1) 4 lamp023 - (1) 2 lamp, (1) 3 lamp033 - (2) 3 lamp024 - (1) 2 lamp, (1) 4 lamp222 - (3) 2 lamp

Ballast Configuration

CUT SHEET: FLUORESCENT HIGH BAY T8 SURFACE MOUNT

24”

24”

4”

ABCDE

A = 48” Length B = 28” (7/8 K.O.) C = 24” (2” K.O.) D = 6” (3/8” holes for surface mounting) E = 4” (7/8” K.O.)

Top view

4”

End view

7/8” K.O.

Page 2: Fluorescent High Bay T8 Surface Mount

8812 Frey Road, Houston, TX 77034 P (713) 943-9927 F (713) 943-2818 www.xtralight.com [email protected]

xTraLigHT.COm

FLUORESCENT HIGH BAY T8 SURFACE MOUNT

pHOTOMETRIC dATA

dIMENSIONAL dATA

2843

3791

1895

948

4723

3542

2362

1181

5903

4427

2952

1476

4082

3062

2041

1021

4723

3542

2361

1181

6282

4711

3141

1570

fHS 4X32 clear Lens• Spacing Criteria = 1.4• Efficiency = 83%

fHS 4X32 P12 Lens• Spacing Criteria = 1.3• Efficiency = 78%

fHS 5X32 clear Lens• Spacing Criteria = 1.8• Efficiency = 81%

fHS 5X32 P12 Lens• Spacing Criteria = 1.5• Efficiency = 78%

fHS 6X32 clear Lens• Spacing Criteria = 1.2• Efficiency = 78%

fHS 6X32 P12 Lens• Spacing Criteria = 1.1• Efficiency = 74%

CUT SHEET: FLUORESCENT HIGH BAY T8 SURFACE MOUNT

Enhancedaluminumopticsdatashown.

24”

24”

4”

ABCDE

A = 48” Length B = 28” (7/8 K.O.) C = 24” (2” K.O.) D = 6” (3/8” holes for surface mounting) E = 4” (7/8” K.O.)

Top view

4”

End view

7/8” K.O.