General Features www.vision-batt.com VISION Rechargeable Products Sealed Lead Acid Battery VISION FM series are designed for general purpose applications, such as UPS, telecom, electrical utilities. With 10 years design life, the batteries comply to the most popular international standards, such as IEC896-2, BS6290-4, Eurobat Guide. The battery container and cover are available both in V0 class flame retardant ABS or HBO ABS plastics. Shenzhen Center Power Tech Co., Ltd. has come to obtain wide recognition from customers all over the world. This is not only due to the fact that our products are featured by reliable stability in quality, but also because we attach great importance to our communication with customers and our perfect understanding of customers' requirements as well. General purpose application Dimensions and Weight 6FM40-X 12V 40Ah Low Pressure Venting System Low Self Discharge U. L. Component Recognition o Six months shelf life at 20 C Design life 10 years Positive and negative plates in lead-calcium-tin alloy Stable Quality & High Reliability Sealed Construction Long Service Life Maintenance-Free Operation Shenzhen Center Power Tech. Co., Ltd SI Units English Units Length 197mm 7.76inch Width 165mm 6.50inch Height 170mm 6.69inch Total Height 170mm 6.69inch Approx. Weight 13.5Kg 29.8lbs Performance Characteristics Nominal Voltage 12V Number of cell 6 o o Nominal Capacity 77 F(25 C) 10 hour rate (4.00A, 10.8V) 40.0Ah 5 hour rate (7.00A, 10.5V) 35.0Ah 1 hour rate (25.9A, 9.60V) 25.9Ah Internal Resistance o o Fully Charged battery 77 F(25 C) 9.5mOhms Self-Discharge o 3% of capacity declined per month at 20 C(average) Operating Temperature Range o Discharge -20~60 C o Charge -10~60 C o Storage -20~60 C o o Max. Discharge Current 77 F(25 C) 400A(5s) Short Circuit Current 900A o o Charge Methods: Constant Voltage Charge 77 F(25 C) Cycle use 14.4-14.7V Maximum charging current 12A o Temperature compensation -30mV/ C Standby use 13.6-13.8V o Temperature compensation -20mV/ C The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Sulfuric acid Fiberglass Copper Rubber ABS ABS Lead Lead dioxide Raw material

Upload: nguyentuong

Post on 25-Apr-2018

217 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: FM-PDF - Solarguru · standards, such as IEC896-2, BS6290-4, Eurobat Guide. The battery container and cover are available both in V0 class flame retardant ABS or HBO ABS plastics

General Features

www.vision-batt.com

VISION Rechargeable ProductsSealed Lead Acid Battery

VISION FM series are designed for general purpose applications, such as UPS,telecom, electrical utilities.

With 10 years design life, the batteriescomply to the most popular internationalstandards, such as IEC896-2, BS6290-4,Eurobat Guide.

The battery container and cover areavailable both in V0 class flame retardantABS or HBO ABS plastics.

Shenzhen Center Power Tech Co., Ltd. has come to obtain wide recognition fromcustomers all over the world. This is not only due to the fact that our products are featured by reliable stability in quality, butalso because we attach great importance to our communication with customers andour perfect understanding of customers' requirements as well.

General purpose application

Dimensions and Weight

6FM40-X 12V 40Ah

Low Pressure Venting System

Low Self Discharge

U. L. Component Recognition

oSix months shelf life at 20 C

Design life 10 years

Positive and negative plates in lead-calcium-tin alloy

Stable Quality & High Reliability

Sealed Construction

Long Service Life

Maintenance-Free Operation

Shenzhen Center Power Tech. Co., Ltd

SI Units English Units

Length 197mm 7.76inch

Width 165mm 6.50inch

Height 170mm 6.69inch

Total Height 170mm 6.69inch

Approx. Weight 13.5Kg 29.8lbs

Performance Characteristics

Nominal Voltage 12V Number of cell 6

o o Nominal Capacity 77 F(25 C) 10 hour rate (4.00A, 10.8V) 40.0Ah 5 hour rate (7.00A, 10.5V) 35.0Ah 1 hour rate (25.9A, 9.60V) 25.9Ah Internal Resistance

o o Fully Charged battery 77 F(25 C) 9.5mOhms Self-Discharge

o 3% of capacity declined per month at 20 C(average)

Operating Temperature Rangeo Discharge -20~60 C

o Charge -10~60 Co Storage -20~60 C

o o Max. Discharge Current 77 F(25 C) 400A(5s) Short Circuit Current 900A

o o Charge Methods: Constant Voltage Charge 77 F(25 C) Cycle use 14.4-14.7V Maximum charging current 12A

o Temperature compensation -30mV/ C Standby use 13.6-13.8V

o Temperature compensation -20mV/ C

The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position.

Battery Construction

Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte

Sulfuric acidFiberglassCopperRubberABSABSLeadLead dioxideRaw material

Page 2: FM-PDF - Solarguru · standards, such as IEC896-2, BS6290-4, Eurobat Guide. The battery container and cover are available both in V0 class flame retardant ABS or HBO ABS plastics

Discharge Data

Shenzhen Center Power Tech. Co., Ltd

6FM40-X 12V 40Ahwww.vision-batt.com

VISION Rechargeable ProductsSealed Lead Acid Battery

End VoltagePer cell / V

End VoltagePer cell / V

Constant Current

1

10

100

1000

1 10 100 1000 10000

Time/mins

Cur

rent

/A

Constant Power

1

10

100

1000

1 10 100 1000 10000

Time/minsW

atta

ge/W

1.60 131 93.0 73.3 57.6 48.3 42.0 37.4 34.0 31.3 29.1 27.4 25.9 18.3 14.5 12.2 10.7 8.60 7.36 6.33 5.60 5.05 4.62 4.28 3.61 1.87

1.65 124 88.4 68.9 54.8 46.3 40.7 36.4 33.1 30.6 28.6 27.0 25.6 18.0 14.2 11.9 10.4 8.43 7.24 6.23 5.51 4.98 4.56 4.22 3.55 1.86

1.70 119 83.7 66.7 52.8 44.5 39.0 35.3 32.6 30.5 28.4 26.6 25.2 17.7 14.0 11.7 10.2 8.27 7.11 6.14 5.45 4.93 4.53 4.21 3.52 1.84

1.75 110 79.1 64.9 51.5 43.4 38.0 34.3 31.5 29.3 27.5 26.1 24.9 17.4 13.7 11.4 9.95 8.11 7.00 6.02 5.33 4.81 4.40 4.07 3.48 1.82

1.80 101 71.9 58.7 47.5 40.8 36.3 33.1 30.8 28.9 26.9 25.2 23.8 16.8 13.2 11.1 9.72 7.90 6.80 5.87 5.20 4.70 4.31 4.00 3.40 1.79

1.60 251 177 141 117 103 92.9 83.1 75.7 70.0 64.2 59.5 55.6 39.3 31.2 26.3 23.0 18.0 15.0 12.9 11.5 10.2 9.29 8.71 7.38 3.97

1.65 233 163 128 105 91.9 82.9 74.7 68.6 63.8 58.8 54.6 51.2 36.5 29.1 24.7 21.7 17.0 14.1 12.2 10.9 9.90 9.12 8.50 7.25 3.90

1.70 215 155 124 102 89.0 80.3 71.8 65.5 60.5 56.4 53.1 50.3 35.6 28.3 23.8 20.9 16.5 13.9 12.1 10.8 9.79 9.03 8.42 7.16 3.85

1.75 198 148 120 98.9 86.2 77.7 69.8 63.9 59.3 55.4 52.2 49.5 35.1 27.8 23.5 20.6 16.3 13.7 11.9 10.6 9.58 8.82 8.21 6.98 3.76

1.80 186 140 116 95.5 83.2 75.0 67.7 62.3 58.0 54.2 51.2 48.6 34.4 27.3 23.0 20.2 16.1 13.6 11.7 10.4 9.43 8.66 8.04 6.84 3.68

5min 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min 1h 1.5h 2h 2.5h 3h 4h 5h 6h 7h 8h 9h 10h 12h 24h

5min 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min 1h 1.5h 2h 2.5h 3h 4h 5h 6h 7h 8h 9h 10h 12h 24h

1.60V 1.65V 1.70V1.75V 1.80V

1.60V 1.65V 1.70V1.75V 1.80V

oConstant Current Discharge Data ( Amperes at 25 C )

oConstant Power Discharge Data ( Watts per cell at 25 C )

Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, ChinaTel: 86 755 8431 8088 Fax: 86 755 8431 8038 E-mail: [email protected] Website: http://www.vision-batt.com

(Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values.

Page 3: FM-PDF - Solarguru · standards, such as IEC896-2, BS6290-4, Eurobat Guide. The battery container and cover are available both in V0 class flame retardant ABS or HBO ABS plastics

Shenzhen Center Power Tech. Co., Ltd

6FM40-X 12V 40Ahwww.vision-batt.com

VISION Rechargeable ProductsSealed Lead Acid Battery

Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, ChinaTel: 86 755 8431 8088 Fax: 86 755 8431 8038 E-mail: [email protected] Website: http://www.vision-batt.com

Self-discharge characteristic

Life characteristics of Standby use Cycle service life in relation todepth of discharge

110

100

90

80

70

60

50

400 2 4 6 8 10 12 14 16 18 20

Storage time: months

Cap

acity

(%)

Cap

acit y

(%)

120

100

80

60

40

20

0 4 6 8Life(year) Number of cycles(cycles)

Cap

acity

(%)

120

100

80

60

40

20

0 200 400 600 800 1000 1200 1400

Charging time (hours)

Cha

rged

Vol

u me

(%)

Cur

rent

(XCA)

Vol

tage

(V)

15.0

14.0

13.0

12.0

11.0

0.25

0.20

0.15

0.10

0.05

00 2 4 6 8 10 12 14 16 18 20

140

120

100

80

60

40

20

0

Constant voltage chargingocharacteristic (0.25CA,25 C)

CHARGED VOLUME

CHARGE VOLTAGE

CHARGING CURRENT

Relationship betweencharging voltage and temperature

-10 0 10 20 30 40 50 60oAmbient temperature( C)

2.6

2.5

2.4

2.3

2.2

5.2

5.0

4.8

4.6

4.4

7.8

7.5

7.2

6.9

6.6

10.4

10.0

9.6

9.2

8.8

15.6

15.0

14.4

13.8

13.2

(V/1

2V)

(V/C

ELL )

( V/8

V)

(V/ 6

V)

(V/4

V)

% Depth of30 discharge

ODischarge characteristic (25 C)

min hDischarge time

Vol

tage

(v)

13.0

12.0

11.0

10.0

9.0

8.0

01 2 3 5 10 20 30 60 2 3 5 10 20 300

Temperature effects on float life

Temperature effects on capacity

15

5

10

0

120

100

80

60

40

20

0o-20 -10 0 10 20 30 40 50( C)

Life

(yea

rs)

oTemperature( C)

Cap

acity

(%)

10 20 30 40 50