foamglas insulation, sustainable design, and leed v4

11
1 © 2014 Pittsburgh Corning FOAMGLAS ® INSULATION, SUSTAINABLE DESIGN, AND LEED ® V4 A REPORT TO PITTSBURGH CORNING ON THE ATTRIBUTES ON FOAMGLAS ® CELLULAR GLASS INSULATION RELATIVE TO SUSTAINABLE BUILDING DESIGN. CHRISTINE A. SUBASIC, P.E., LEED AP 5/19/2014 © 2014 PITTSBURGH CORNING

Upload: others

Post on 01-Mar-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

1©2014 Pittsburgh Corning

FOAMGLAS® INSULATION,SUSTAINABLE DESIGN, AND LEED® V4A REPORT TO PITTSBURGH CORNING ON THE ATTRIBUTES ON FOAMGLAS® CELLULAR GLASS INSULATION RELATIVE TO SUSTAINABLE BUILDING DESIGN.

CHRISTINE A. SUBASIC, P.E., LEED AP 5/19/2014

©2014 PITTSBURGH CORNING

Page 2: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

2©2014 Pittsburgh Corning

FOAMGLAS® INSULATION, SUSTAINABLE DESIGN, AND LEED® V4

1 http://www.usgbc.org/articles/three-billion-square-feet-green-building-space-leed%C2%AE-certified accessed May 2014.2 For more information on the RED LIST, see http://declareproducts.com/content/declare-and-living-building-challenge.

Introduction Green building is firmly established in the commercial new construction market, and demand for green building materials continues to grow. As of April 2014, the U.S. Green Building Council (USGBC®) has certified 3 billion square feet of building space throughout the world1. Numerous federal government agencies and state governments have enacted green building initiatives. In many cases, these initiatives move beyond voluntary measures to actual LEED®certification requirements for public and in some cases, private, new construction. Further contributing to movement toward green building mandates is the development of the 2012 International Green Construction CodeTM (IgCCTM), an overlay code written in mandatory language for adoption in conjunction with the International Building Code.

The nature of green building criteria also continues to evolve. The newest version of the Leadership in Energy and Environmental Design®, or LEED®, rating systems, known as LEED v4 introduced a new approach for building materials and products. While some of the former credits remain, LEED v4 introduced three entirely new credits in the Materials & Resources section focused on product disclosure. This white paper examines these new credits and others in LEED v4 and their connection with FOAMGLAS® cellular glass insulation and accessory products.

Green building is not however, necessarily the same as sustainable design. Sustainable design refers to the design and construction of buildings in a way that meets the needs of today without compromising the needs of the future. With green building the focus is often limited to environmental impacts, but true sustainable design considers the economic and social aspects of the design in addition to the environmental impacts and looks to balance this “triple bottom line.” Sustainable building design is a holistic look at the entire building process. As a result, this report also includes other aspects of sustainable design that may not be included in current green building rating programs.

FOAMGLAS® Insulation and Accessory Adhesive & Sealant ProductsThis report evaluates FOAMGLAS® cellular glass insulation manufactured by Pittsburgh Corning, as well as PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant as used in sustainable commercial building designs. Though many of these sustainable strategies may also be appropriate for residential construction, the residential market has several unique aspects that are not covered here. Insights into the suitability of FOAMGLAS® cellular glass insulation, PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant for sustainable design strategies are based on information provided by Pittsburgh Corning and information obtained online.

Evaluating the applicability to sustainable design strategies requires an understanding of the use of the product and its manufacture. Based on information received from Pittsburgh Corning and that obtained online, the following generalizations can be made.

FOAMGLAS® cellular glass insulation is currently used globally in industrial applications, such as pipe and mechanical systems, as well as for building envelope applications such as roof, wall and sub-slab insulation. FOAMGLAS® cellular glass insulation is characterized by high compressive strength, resistance to moisture, and resistance to fire. While some other rigid insulating materials such as polyisocyanurate or polystyrene may have a higher initial insulating value, the thermal properties of FOAMGLAS® cellular glass insulation have demonstrated a longer useful life, even when exposed to moisture. Other common building insulations can rapidly lose their insulating properties when subject to moisture or settling. Furthermore, FOAMGLAS® cellular glass insulation has no RED LISTED2 components and is safe for workers to install in accordance with Pittsburgh Corning’s guide specifications.

Page 3: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

3©2014 Pittsburgh Corning

FOAMGLAS® cellular glass insulation is manufactured primarily from sand, limestone and soda ash. The raw materials are melted and the resulting glass is crushed to a fine powder and mixed with a cellulating agent. The powder is dispensed into molds, and sintered and cellulated (chemical reaction at high temperature) to form large buns. The buns are annealed to eliminate stress and limit breakage. The buns are trimmed into blocks of required size (18”x24”x thickness up to 7”) and then packaged. In this block form, FOAMGLAS® cellular glass insulation can be used directly as wall, roof or below grade insulation. FOAMGLAS® cellular glass insulation can be fabricated into pipe insulation or other shapes made from blocks. This fabrication may occur at separate authorized facilities not owned by Pittsburgh Corning.

The melting furnace is fueled by natural gas and electricity. Waste heat is captured in the glass melting process and is reused to preheat combustion air for the melting oven. Cellulating furnaces and annealing ovens are fueled by natural gas. Water used in the process to cool equipment is re-circulated and recycled. A minimal amount of fresh water is used to prepare molds. At present no post consumer recycled materials are used in the manufacture of FOAMGLAS® cellular glass insulation in the U.S., though European facilities use 30% or more post-consumer recycled glass content in their manufacture of FOAMGLAS® cellular glass insulation.

PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL CW Sealant are low-VOC products used in assembling FOAMGLAS® cellular glass insulation components into piping and equipment insulation systems and/or building insulation systems.

Evaluating Sustainable DesignThe most widely used commercial green building assessment tool in the U.S. is the LEED® for New Construction rating system. However, there are several other green building standards available for use. These include the Green Building Assessment Protocol for Commercial Buildings© (ANSI/GBI 01-2010), the Standard for High-Performance Green Buildings Except Low-Rise Residential Buildings© (ANSI/ASHRAE/USGBC/IES Standard 189.1-2011) and the National Green Building StandardTM (NAHB/ICC 700-2012) for residential construction. In addition, the International Code Council in conjunction with several other organizations has developed the 2012 International Green Construction CodeTM (IgCCTM) as a mandatory language overlay code for use with the International Building Code. The Canada Green Building Council also offers a LEED® rating system that is slightly different from the U.S. version. A brief description of each program follows.

The Green Building Assessment Protocol for Commercial Buildings© (ANSI/GBI 01-2010) is a consensus standard developed by the Green Building Initiative (GBI) and based on the Green Globes online building and management environmental audit. It allows for either self-assessment or third-party verification of a building’s design and construction.

The Standard for High-Performance Green Buildings Except Low-Rise Residential Buildings© (ANSI/ASHRAE/USGBC/IES Standard 189.1-2011) is a consensus standard based on LEED for New Construction. This standard is intended for adoption by local jurisdictions and is written in mandatory language with both prescriptive and performance compliance paths. It is an accepted compliance path within the 2012 IgCC.

The National Green Building StandardTM (NAHB/ICC 700-2012) was developed by the National Association of Home Builders (NAHB) and the International Code Council. This standard covers residential construction, including neighborhood development.

2012 International Green Construction CodeTM (2012 IgCCTM) was developed by International Code Council, sponsors such as ASTM International, the U.S. Green Building Council and others, and numerous stakeholders. The IgCC is an overlay code meant to be adopted in conjunction with the International Building Code. It is written in mandatory language with some jurisdictional choice. It is a minimum green building code and contains many of the same requirements as the other green building programs. However it also includes provisions for life cycle assessment and building service life.

Page 4: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

4©2014 Pittsburgh Corning

LEED® for New Construction is a tool for assessing the energy and environmental impact of buildings that was developed by the U.S. Green Building Council (USGBC®). LEED® stands for Leadership in Energy and Environmental Design, and USGBC has developed several rating systems for the different types of construction in the building industry, including new construction, existing buildings, schools, etc. The LEED rating systems are voluntary rating systems that provide a third-party certification to define what constitutes a “green” building.

The LEED® Canada for New Construction 2009 rating system is based on the U.S. version of LEED 2009. Some of the most notable differences for building products are that LEED Canada for New Construction 2009 includes a credit for utilizing durable materials, recognizes differences in method of transport for building products, and uses a specific recycled content calculation for products utilizing cement replacements (supplementary cementing materials). Going forward Canada will not develop a separate rating system, but will instead support Alternative Compliance Paths for LEED v4.

While each of these rating systems is slightly different in content and approach, there is general agreement on the importance of evaluating:

• energy efficiency • water efficiency • land use (sites) • materials and resources (resource efficiency) • pollution (global impact) • indoor environmental quality (health and well being) • transport • operations and maintenance

However, sustainable design encompasses many elements not included in LEED or other assessment tools. A better tool for evaluating sustainable design is found in the Principles of High Performance School Buildings developed by the Sustainable Buildings Industry Council. These principles of high performance, sustainable building design are:

• Environmentally responsive site planning • Energy efficient building shell • Thermal comfort • Energy analysis • Renewable energy • Water efficiency • Safety and security • Daylighting • Commissioning • Environmentally preferable materials and products • High performance HVAC • High performance electric lighting • Life cycle cost analysis • Acoustic comfort • Superior indoor air quality • Visual comfort

This framework of principles of high performance buildings provides consideration of several elements not covered in many green building programs that are key to sustainable design. These include durability, efficient use of materials, avoidance of waste, life cycle costs, environmental life cycle assessment, and safety and security. Fortunately as LEED and other green building programs continue to evolve, some of these important aspects, such as avoidance of waste and life cycle assessment, are being included.

Page 5: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

5©2014 Pittsburgh Corning

FOAMGLAS® Insulation, Accessory Products and Sustainable Design PrinciplesThe applicability of a product to a sustainable building design strategy depends both on its use and on characteristics of its manufacture. This section describes the high performance sustainable design principles applicable to FOAMGLAS® cellular glass insulation, PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant.

ENVIRONMENTALLY RESPONSIVE SITE PLANNINGEnvironmentally responsive site planning includes consideration of site selection, site disturbance, storm water management, and effect of the building on its surroundings. One area of interest is the use of vegetated (“green”) roofs. Vegetated roofs are increasingly used on sustainable building designs to reduce the heat island effect and reduce storm water runoff from the roof. The heat island effect is that effect whereby dark colored surfaces retain excess heat creating a microclimate. This is why oftentimes nighttime temperatures in the countryside are much cooler than in a city. The heat island effect can be reduced by shading of horizontal surfaces and by utilizing light-colored, reflective materials, or by introducing vegetation. Vegetation absorbs moisture and provides an evaporative cooling effect on the roof. FOAMGLAS® cellular glass insulation is especially suited for use under a vegetated roof because of its high compressive strength and resistance to moisture. ENERGY EFFICIENT BUILDING SHELL, THERMAL COMFORT, AND ENERGY ANALYSISAn energy efficient building envelope is a key component in sustainable building design. Achieving an energy efficient building envelope includes consideration of both the insulating value of materials as well as the thermal mass of materials.

FOAMGLAS® cellular glass insulation can be used to provide the necessary insulation for the building envelope, in both vertical (wall) applications and horizontal (roof/sub-slab) applications. Cavity wall applications for FOAMGLAS® cellular glass insulation pose a challenge in that the required thickness to achieve the necessary R-value may exceed the allowable cavity width requiring engineering of wall ties. Applications such as foundation insulation, exterior wall insulation, and roof insulation are best suited to FOAMGLAS® cellular glass. The high compressive strength of FOAMGLAS® cellular glass insulation may provide an advantage for structures in which the roof bears a high load, such as vegetated roofs, parking decks, and terraces.

SAFETY AND SECURITYSafety and security are two aspects of sustainable design that are not covered by the LEED rating systems. Fire-resistant construction and resistance to impacts and wind-borne debris promote occupant health and safety. FOAMGLAS® cellular glass insulation is non-combustible.

HIGH PERFORMANCE HVAC High performance HVAC systems are designed to respond to occupancy and environmental conditions. High performance HVAC systems may incorporate cooling by flushing with night air under appropriate environmental conditions, or the use of ground-source heat pumps. High performance HVAC also includes use of equipment that does not contain HCFC’s and halons. FOAMGLAS® cellular glass insulation is often used as piping or duct insulation in HVAC&R applications such as these.

ENVIRONMENTALLY PREFERABLE MATERIALS AND PRODUCTSConsideration of the environmental impact of building materials and products is an important element in a sustainable design, though it is only one of several criteria to be considered for product selection. Materials should be evaluated over their entire life cycle, from raw material extraction to end of useful life. This life cycle assessment (LCA) of a building material or product must include accurate evaluation of product service life.

Page 6: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

6©2014 Pittsburgh Corning

There are several aspects to consider in the environmental evaluation of building materials. Life cycle assessment allows for a complete examination of all aspects of building material manufacture and use. It includes all impacts from raw material acquisition to manufacturing to building maintenance and end of building life. This is often called “cradle to grave” for building materials. However in the U.S., life cycle assessment of building materials is often lacking. Few manufacturers can provide such robust information about their products. As a result, green building rating systems often include single attribute measures of environmental impact, as well as measures that reflect on-site construction practices. In this context environmentally preferred products should incorporate one or more of the following strategies:

• Abundance of raw materials • Efficient use of raw materials • Use of bio-based or rapidly renewable materials • Use of recycled materials • Sustainable measures in acquisition or manufacture • Use of regionally available materials (near to building project site) • Regional manufacture or fabrication (near to building project site) • Recyclable • Salvageable • Durable • Non-toxic (not made of toxic materials) • Avoidance of construction waste

FOAMGLAS® cellular glass insulation may incorporate several of these sustainable strategies. FOAMGLAS® cellular glass insulation is made in large part from sand which is considered an abundant raw material. FOAMGLAS® cellular glass insulation manufacturing has little waste. Roughly 90% of raw materials are used in the final product. Opportunity exists for obtaining raw materials close to the manufacturing plant. The Sedalia plant sources approximately 75% (by weight) of its raw materials from within 500 miles of the factory, and 63% within 100 miles of the factory, although in the LEED® rating systems it is the distance between material extraction, as well as manufacture, and the project site that is calculated.

FOAMGLAS® cellular glass insulation is 100% glass, and as such, is recyclable. FOAMGLAS® cellular glass insulation is durable and requires little or no maintenance. FOAMGLAS® cellular glass insulation is inert, is not made from toxic materials (no HCFC’s), and retains its physical properties for its entire life span.

FOAMGLAS® cellular glass insulation can be made of recycled materials, though it is not presently done in the U.S. Pittsburgh Corning’s European facilities use 30% or more post-consumer recycled glass content in the production of FOAMGLAS® cellular glass insulation.

LIFE CYCLE COST ANALYSISCosts of building materials should be considered over the entire life span of the building. Durable materials like glass products generally have an advantage in that because of their long life and low maintenance, their life cycle costs are often low as compared with products that have a low initial cost but high life cycle cost.

ACOUSTIC COMFORTAcoustic comfort is another important element in sustainable designs. Walls with high Sound Transmission Class (STC) values provide superior acoustic insulation. FOAMGLAS® cellular glass insulation used in a building envelope can nominally contribute to achieving the minimum STC for walls of 50 required by most rating systems with acoustic criteria.

Page 7: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

7©2014 Pittsburgh Corning

SUPERIOR INDOOR AIR QUALITYSuperior indoor air quality encompasses both the reduction/elimination of pollutants in a building (i.e. tobacco smoke, chemical pollutants) as well as moisture control to help prohibit mold. FOAMGLAS® cellular glass insulation is inert, is not a food source for pests or rodents, does not support mold growth, does not produce volatile organic compounds (VOCs) nor any hazardous chemicals currently designated as having high health risks. PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant are low VOC products that meet the general requirements for VOC emissions of SCAQMD Rule 1168, July 1, 2005 adhesive and sealant applications, as analyzed by the methods specified in Rule 1168.

The LEED® v4 Rating SystemIn fall 2013 U.S. Green Building Council formally launched LEED v4. The suite of LEED rating systems that make up LEED v4 now addresses an even broader array of buildings that make up 21 different market sectors. LEED rating systems are organized into the broad categories of building design and construction (BD+C), interior design and construction (ID+C), building operations and maintenance (O+M), neighborhood development (ND) and homes (HOMES). Within each of these broad categories numerous types of construction are covered. One of the most widely used rating systems is BD+C New Construction. As a result, this white paper focuses on the credits found in this rating system.

LEED v4 has a renewed focus on reducing contributions to global climate change as well as enhancing human health and quality of life. The point distribution among various credits reflects these stated priorities and has resulted in modifications from the previous version. Totally new credits have been introduced in LEED v4, while others have been eliminated. The total number of available points remains unchanged at 110 points, as do the certification levels (Figure 1). However the organization of the credits has been changed.

In LEED v4 the credits are organized into eight categories plus a new credit for Integrative Process (Figure 2). The former Sustainable Sites category has been split into two: Sustainable Sites (SS) and Location and Transportation (LT). The SS contains those credits related to site development while LT contains those credits focused on site selection and its location. A new credit has been added in each category, but the essential aspects of the credits remain unchanged.

FIGURE 1:LEED® v4 Certification Levels

FIGURE 2:LEED® v4 Categories

16

10

11

33

13

16

64 1 Location and Transportation

Sustainable Sites

Water Efficiency

Energy and Atmosphere

Materials and Resources

Indoor Environmental Quality

Innovation

Regional Priority

Integrative Process

Total Possible

Platinum

Gold

Silver

Certified

......................................................................................0 20 40 60 80 100 120

110

80

60

50

40

Page 8: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

8©2014 Pittsburgh Corning

Changes to Materials and Resources in LEED® v4The most significant changes in LEED v4 occurred in the Materials and Resources category. In LEED 2009 the Materials and Resources (MR) category awarded points in credits focused on the attributes of recycled content, regional materials, rapidly renewable materials, and certified wood, as well as reuse of materials and construction waste management. LEED v4 takes an entirely different approach. The focus of MR in LEED v4 is on product transparency. Six of the 13 possible points relate to product ingredient disclosure, including environmental product declarations (EPD), supply chain reporting and material ingredient reporting. Other significant changes in the MR category include the addition of whole building life cycle assessment and the elimination of regional materials as a stand-alone credit. The credits that form the MR category in LEED v4 are shown in Table 1.

Table 1: LEED v4 Materials and Resources Category

LEED® v4 Credits and FOAMGLAS® Insulation and Accessory ProductsFOAMGLAS® cellular glass insulation, PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant can contribute toward earning LEED® points on a project in several credit categories as described below.

SUSTAINABLE SITESCredit 4 – Rainwater ManagementCredit 5 – Heat Island ReductionFOAMGLAS® cellular glass insulation can be part of a vegetated roof design which is one sustainable strategy that can be used to earn both of these Sustainable Sites credits.

CREDIT LEED v4 POINTS DESCRIPTION

Prereq 1............Storage and Collection of Recyclables.......................................Req’d...............Requires a place for storage and collection of RecyclablesPrereq 2............Construction & Demolition Waste Management Planning.....Req’d...............Requires implementation of a construction waste management plan.Credit 1.............Building Life-Cycle Impact Reduction..............................................5.................Options 1-3 reward reuse of buildings and materials. Option 4 covers whole building life cycle assessment for new construction.Credit 2.............Building Product Disclosure and Optimization -.............................2................Rewards reporting of environmental impacts Environmental Product Declarations building products.Credit 3.............Building Product Disclosure and Optimization -.............................2................Rewards reporting of raw material sources Sourcing of Raw Materials & type of raw materials (i.e. recycled content).Credit 4.............Building Product Disclosure and Optimization -.............................2................Rewards material ingredient disclosure via Material Ingredients chemical screening tools.Credit 5.............Construction and Demolition Waste Management.......................2................Rewards diversion of wastes from landfill in addition to reduction of total construction waste.

Page 9: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

9©2014 Pittsburgh Corning

ENERGY & ATMOSPHEREPrerequisite 2 – Minimum Energy Performance Credit 2 - Optimize Energy Performance FOAMGLAS® cellular glass insulation can be used as part of strategies to help achieve the required energy performance and to further reduce the amount of energy consumed by the building.

MATERIALS & RESOURCESRegional materials is no longer a stand-alone credit in LEED v4 but has been incorporated as weighting multiplier in MR credits 2, 3 and 4. Products that meet the criteria specified in these credits that are sourced (extracted, manufactured, purchased) within 100 miles (160 km) of the project site are valued at 200% of their base contributing cost. Note that this provision does not apply to all options within these credits. See http://www.usgbc.org/credits/new-construction/v4/material-%26-resources for more information.

Credit 2 - Building Product Disclosure and Optimization - Environmental Product Declarations (EPD)An EPD is available for FOAMGLAS® manufactured in the European Union at www.pe-international.com/uploads/media/IBU_Declaration_Foamglas.pdf. Due to differences in raw materials and manufacturing process, an EPD for FOAMGLAS® manufactured in North America is not currently available.

Credit 3 - Building Product Disclosure and Optimization - Sourcing of Raw Materials Option 1: Raw material source and extraction reporting This option requires a third-party verified report prepared in accordance with the GRI Framework. Though FOAMGLAS® insulation does not currently meet this requirement, a sustainability report, Our Journey. From Environmental Responsibility to Long Term Sustainability, is available on their website. The intention is for future reports to be done in compliance with the GRI Framework.Option 2: Leadership extraction practicesFOAMGLAS® insulation produced in the European Union contains at least 30% post-consumer recycled glass from windshields.

Credit 4 - Building Product Disclosure and Optimization - Material IngredientsOption 1: Material ingredient reporting FOAMGLAS® insulation has prepared chemical inventory of the product to at least 0.1% (1000 ppm) using Chemical Abstracts Service Registry Numbers (CASRN) which can be obtained upon request.Option 2: Material ingredient optimization Though FOAMGLAS® insulation is not yet certified compliant with GreenScreen v1.2 Benchmark plans are underway to pursue this certification.

FOAMGLAS® cellular glass insulation is also manufactured without the use of HCFC’s and is often used as part of HVAC&R systems that do not use HCFC’s.

Credit 5 – Construction Waste Management Option 1: DiversionFOAMGLAS® cellular glass insulation scrap construction waste can be recycled.

INDOOR ENVIRONMENTAL QUALITYCredit 2 – Low-Emitting Materials –Though insulation is not considered in this section, FOAMGLAS® cellular glass insulation would also eliminate another potential source of VOC’s in a building. PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant are low VOC products that meet the requirements of this credit.

Page 10: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

10©2014 Pittsburgh Corning

SUMMARY OF LEED® CREDITS FOR FOAMGLAS® INSULATION AND ACCESSORY PRODUCTSFOAMGLAS® cellular glass insulation as currently manufactured can be part of a strategy to earn points in the following LEED®v4 credits.

• SUSTAINABLE SITES o Credit 4 – Rainwater Management o Credit 5 – Heat Island Reduction• ENERGY AND ATMOSPHERE o Prerequisite 2 – Minimum Energy Performance o Credit 2 - Optimize Energy Performance • MATERIALS AND RESOURCES o Credit 2 - Building Product Disclosure and Optimization- Environmental Product Declarations (EPD) o Credit 3 - Building Product Disclosure and Optimization - Sourcing of Raw Materials • Option 2: Leadership extraction practices (European Union plants) o Credit 4 - Building Product Disclosure and Optimization - Material Ingredients • Option 1: Material ingredient reporting - subject to publication of CASRN • Option 2: Material ingredient optimization - subject to successful completion of GreenScreen Benchmark 1.2 o Credit 5 – Construction Waste Management

When the project site is within 100 miles of the manufacturing location, FOAMGLAS® insulation may also qualify as a regional material as part of MR credits 2, 3 and 4.

• INDOOR ENVIRONMENTAL QUALITY o Credit 2 – low-emitting materials

PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant can contribute toward LEED® v4 Credit on IEQ Credit 2, Low-Emitting Materials.

Other Green Rating ProgramsFOAMGLAS® cellular glass insulation has been named a certified Living Building Challenge RED LIST FREE product. This certification is part of the ingredient transparency program administered by the International Living Future Institute’s Living Building Challenge. The Living Building Challenge’s Declare program requires participating manufacturers to provide a material ingredients list, fostering transparency in the marketplace. Products that have been Declared “Red List Free” are eligible for use on Living Building Challenge projects. The Red List is composed of 14 materials and chemicals, all of which have been deemed “worst in class” for their effects on human health and the environment. FOAMGLAS® cellular glass insulation does not contain CFCs, HCFCs or any other hazardous materials or compounds. The RED LIST FREE labels for FOAMGLAS® products can be found in the International Living Future Institute’s database: FGL-0001 / FGLz-0002.

FOAMGLAS® cellular glass insulation is GreenSpec® Listed, and was named a Top 10 Green Building Product by BuildingGreen, Inc. in 2010. See BuildingGreen, Inc.’s GreenSpec® Green Building Product Database: http://greenspec.buildinggreen.com/content/pittsburgh-corning for further information.

Page 11: FOAMGLAS INSULATION, SUSTAINABLE DESIGN, AND LEED V4

11©2014 Pittsburgh Corning

SummarySustainable building design goes beyond the often narrow consideration of environmental impacts found in green building rating systems to also consider societal and economic factors. This report provides information on the many ways FOAMGLAS® cellular glass insulation, PC® RTV 450 Silicone Adhesive, PC®99 Adhesive, PITTSEAL® 444N, and PITTSEAL® CW Sealant can contribute to a sustainable building design. In addition, information on FOAMGLAS® products and the new Materials and Resources credits found in LEED v4 is also provided, as well as other product disclosure information provided by Pittsburgh Corning through the Declare and GreenSpec® programs.

FOAMGLAS®, PC® and PITTSEAL® are registered trademarks of Pittsburgh Corning.LEED® and USGBC® are registered trademarks of U.S. Green Building Council.GreenSpec® is a registered trademark of Building Green.