follow-me charge stage coordination and what to expect out of multiple charge controllers....
TRANSCRIPT
![Page 3: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/3.jpg)
*Multiple Charge controllers without Follow-Me*Multiple Charge controllers with Follow-Me*Follow-Me
![Page 4: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/4.jpg)
*Controllers each need a Battery temp sensor*Equalize needs to be started on each controller*Float charges not coordinated *Displays needed for each controller
![Page 5: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/5.jpg)
*1 battery temp sensor needed*EQ, manual or Auto can be controlled by a single controller*Going to Float is coordinated*Single display can view all Follow-Me Classic’s
![Page 6: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/6.jpg)
![Page 7: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/7.jpg)
Programming Follow-Me
Press “Main Menu” and then use the arrows to scroll to “Tweaks” and press “Enter”
![Page 8: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/8.jpg)
Programming Follow-Me
Press the button labeled “More” and Press it again for “More2”
![Page 9: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/9.jpg)
Programming Follow-Me
Press the button labeled “More3” and Press it again for “More4”
![Page 10: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/10.jpg)
Programming Follow-Me
*Set the number for FollowMe*Turn BTS-NET on if wanted*Enter to save*Status button to return to “Home” screen
![Page 11: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/11.jpg)
Ground fault sharing
*Enable ground fault Hardware and software on one Classic only*Enable ground fault Software on any additional Classic’s you wish to turn off on GF
![Page 12: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/12.jpg)
Naming the Classic
*Use the Local App to name the Classic*Name shows up on the display of each Classic making navigating multiple Classic’s easier
![Page 13: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/13.jpg)
Addressing each Classic for viewing on a single MNGP
*Hold Left arrow and tap up or down to change address*Find an unused address to address that Classic to and press and hold left and right arrow till saved (Classic is address 10 by default)*Use the MNGP to address any Lite’s*Hold left arrow and tap up or down arrow to view different Classics on the Follow-Me network
![Page 14: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/14.jpg)
Programming the Classic Lite for Follow-Me
*Use the standard Classic’s MNGP and physically plug it into each Lite and follow the steps from earlier to enable Follow-Me, Battery temp sharing and Addressing of the Lite (If wanted)*Set the MNLP to Custom and plug it in. *MNLP’s from serial # 5435 or older will not work with Follow-Me, either leave them unplugged or contact us for a replacement
![Page 15: Follow-Me charge stage coordination and what to expect out of multiple charge controllers. Customerservice@midnitesolar.com](https://reader030.vdocument.in/reader030/viewer/2022032605/56649e7b5503460f94b7d006/html5/thumbnails/15.jpg)
*Absorb time and voltage must be set on all*Float voltage must be set on all*EQ time and voltage must be set on all*LED1 mode gives visual indication of function*Wind Synch*Cloned settings