forcibly software loading procedure for bts3900 and bts3900a

16
Document Title Security Level: 2009-05-06 HUAWEI Confidential Page1, Total16 Forcibly Software Loading Procedure (Applicable For BTS3900 and BTS3900A) Prepared by: Md. Abdullah-Al-Mamun Staff ID: 00718390 Contents Starting the Site Maintenance Terminal System Locally Logging In to the BTS Forcibly Loading Software of GTMU Activating Software of GTMU Site Opstart Adding DRFU Software Loading of DRFU Activating Software of DRFU Troubleshooting case

Upload: -

Post on 03-Nov-2014

121 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page1, Total16

Forcibly Software Loading Procedure

(Applicable For BTS3900 and BTS3900A)

Prepared by: Md. Abdullah-Al-Mamun Staff ID: 00718390

Contents

� Starting the Site Maintenance Terminal System

� Locally Logging In to the BTS

� Forcibly Loading Software of GTMU

� Activating Software of GTMU

� Site Opstart

� Adding DRFU

� Software Loading of DRFU

� Activating Software of DRFU

� Troubleshooting case

Page 2: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page2, Total16

Starting the Site Maintenance Terminal System

Before starting the Site Maintenance Terminal, firstly, set the IP address of the Site Maintenance Terminal

PC; secondly, connect the Site Maintenance Terminal PC to the BTS; finally, log in to the Site Maintenance

Terminal.

Setting the IP Address of the Site Maintenance Terminal PC

1. Windows XP operating system as an example. On the Windows XP operating system, choose Start >

Control Panel.

2. Select Network Connections. A dialog box is displayed. Right-click the Local Area Connection icon.

3. Choose Properties on the shortcut menu,. The Local Area Connection Properties dialog box is

displayed.

4. Select Internet Protocol (TCP/IP).

5. Click Properties. The Internet Protocol (TCP/IP) Properties dialog box is displayed.

6. Select Use the following IP address.

7. Enter the correct IP address, subnet mask, and default gateway. Ensure that the IP address of the Site

Maintenance Terminal PC and the IP address (192.168.0.72/255.255.255.0) of the BTS are located in the

same network segment, so that a local maintenance path can be set up.

8. Click OK to complete the setting.

Page 3: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page3, Total16

Locally Logging In to the BTS

We can run the Site Maintenance Terminal to directly log in to the BTS.

Prerequisites

• The Site Maintenance Terminal PC is connected properly to the BTS.

• The Site Maintenance Terminal PC is installed with the latest site maintenance terminal software.

Procedure

1. Double-click btsm.exe to start the Site Maintenance Terminal System.

If the communication between the Site Maintenance Terminal PC and the BTS is not set up, the

Communication failed dialog box is displayed, as shown in figure.

2. Click Yes. The Set Communication Port Parameter dialog box is displayed, as shown in figure

3. In the Select Communication Port area, click Network Port. In the Configure IP area, set the IP address

to 192.168.0.72.

Page 4: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page4, Total16

4. Click OK. The Site Maintenance Terminal System window is displayed, as shown in Figure

5. On the Site Maintence Terminal System, choose User and then Login. Enter User Name (Omc by

default) and User Password (omc by default) to log in.

Page 5: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page5, Total16

6. In maintenance console, select the BTS to be maintained, and then press F5. A box for entering the

operation passwords appears at the top of the window. Enter cf + hours (24 hour). If the current time of the

system is 14:32, enter cf14. If the times 9:00am enter cf09, then press Enter.

7. The following Window will displayed with more function

Page 6: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page6, Total16

8. Get Site Management Right. Click OK of the Message box.

Forcibly Loading Software of GTMU

1. This function is performed to load software to the main control board. The main control board of the base

station is the GTMU. Select Site0 > Double Click the Function Forced Software Load. In the dialog box

Browse the required File for GTMU i.e. gtmudown.pck. Enter the latest Version and File ID: GTMU_MAIN.

Then Click Start….

Page 7: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page7, Total16

2. We can view the loading progress in the Site Maintenance Terminal System. If the software is loaded

successfully, the Loading software successfully message is displayed on the status bar.

Activating Software of GTMU

NOTE: Once Software Loading complete wait approximate 2 minute then start Activating Software.

1. Select Site0 > Double Click the Function Software Activation. The dialog box is displayed. In the Version

area, enter the version number. In the File ID drop-down list, select the file ID, as shown in figure

Page 8: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page8, Total16

2. Click OK. The Software activation successfully message is displayed on the status bar at the bottom of

the dialog box.

3. Make sure from the Board Information of GTMU that the loaded Software Version is correct.

Page 9: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page9, Total16

Site Opstart

1. Select Site0 > Double Click the Function Site Opstart.The dialog box is displayed. Click OK.

2. The Site Opstart successfully message is displayed on the status bar at the bottom of the dialog box.

Page 10: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page10, Total16

Adding DRFU

1. In the left pane of the Site Maintenance Terminal System window, select Board. In the right pane of the

window, double-click Board Configuration. The Board Configuration window is displayed Double Click on

GTMU. Then Topology Configuration window is displayed as shown in figure.

2. Collect Topology info first. Click ADD RRU. Deploy DRRU window is displayed enter Card Type; card No,

SFP No and Hop No.

Page 11: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page11, Total16

3. The following example for Single Band (900MHz): TRX configuration 4/4/4.

4. The following example for Duel Band (900 MHz and 1800MHz) 4/4/4 + 4/4/4 Topology configuration:

DRFU Position in Topology config (4/4/4)_ 900MHz

DRFU0 & DRFU1_900

DRFU2 & DRFU3_900

DRFU4 & DRFU5_900

DRFU6 & DRFU7_1800

DRFU8 & DRFU9_1800

DRFU10 & DRFU11_1800

Page 12: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page12, Total16

5. DRFU position info details in Topology configuration:

DRFU0 & DRFU1_900

DRFU6 & DRFU7_1800

DRFU2 & DRFU3_900

DRFU8 & DRFU9_1800

DRFU4 & DRFU5_900

DRFU10 & DRFU11_1800

Page 13: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page13, Total16

Software Loading of DRFU

1. Once DRFU adding complete then Select Site0 > Double Click the Function Forced Software Load. In the

dialog box Browse the required File for DRFU i.e. drfudown.pck. Enter the latest Version and File ID:

DRFU_MAIN. Then Click Start….

2. We can view the loading progress in the Site Maintenance Terminal System. If the software is loaded

successfully, the Loading software successfully message is displayed on the status bar.

Page 14: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page14, Total16

Activating Software of DRFU

1. Select Site0 > Double Click the Function Software Activation. The dialog box is displayed. DRFU board

downloading progress % message is displayed on the status bar at the bottom of the dialog box. So DRFU

software activation starts automatically once loading complete successfully. There are no specified sequences

for activating the software of the boards.

2. Note it will take long time. So have to wait until all DRFU’s loading complete. Once any DRFU downloading

progress 100% complete, check the respective DRFU Board Information the version correct or not.

Page 15: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page15, Total16

Troubleshooting case 1

�Phenomenon Description: Even though GTMU software loading completed successfully the Version still

not updated.

�Suggestions and Summary: This is occurred due to Execute the function Software Activation without

waiting few minutes (approx 2 min) after Loading Software Successfully.

So have to wait few minutes once loading Software Successfully.

Page 16: Forcibly Software Loading Procedure for BTS3900 and BTS3900A

Document Title Security Level:

2009-05-06 HUAWEI Confidential Page16, Total16

Troubleshooting case 2

� Phenomenon Description: Even DRFU Software activation in progress but not completed 100% and

immediately takes other DRFU and continue activation progress.

� Suggestions and Summary: Check how many DRFU failed to update the version and Start the Software

Activation process for those DRFU separately.

Select Site0 > Double Click the Function Software Activation. The dialog box is displayed. In the dialog box

Enter the latest Version, Board No. and File ID: DRFU_MAIN. Then Click OK.

Troubleshooting case 3

� Phenomenon Description: During the activation of the DRFU board software, if the Site Maintenance

Terminal prompts that the software activation failed.

� Suggestions and Summary: Check the communication between the BBU and the DRFU.

1. Check the status of the CPRI0 LED on the GTMU panel of the BBU and the status of the CPRI0 and CPRI1

LEDs on the DRFU panel. All the LEDs are in the on in green status. (The status of the LED corresponding

to the CPRI port that is not in use should be Off.)

2. Check that the signal cables between cascaded DRFUs are securely connected to the CPRI0 and CPRI1

ports.

3. Check that one end of the CPRI signal cable is securely connected to the CPRI0 port on the DRFU and the

other end is securely connected to the CPRI port on the BBU.

4. Check the SFP male connectors at both ends of the CPRI signal cable. If the connector is faulty, replace it.