forgotten password

Upload: ian-abbey

Post on 05-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/2/2019 Forgotten Password

    1/2

    FrequentlyAskedQuestions

    app l i es t o P r oduc t DD5/DD10/DD20/DD30

    Question

    What can you do when you forget the Password ?

    Answer

    Enter the ACCESS menu and toggle down with the Soft key USER (underneath the name of the activated user)

    to the next on this switcher installed ``USER`` and press soft key LOGIN.

    In case the soft key USERS (see top side of the menu) appears then press the corresponding pushbutton.*) Now

    you will get a list of all the installed USER. Toggle with the arrow-buttons to that USER which you can not

    login, because of the unknown password. In the column ``Passwd`` you would have ``NO`` for no password or``YES`` for when a password would be necessary.

    Now select with the soft key PERMIT (right hand upper side) the same permission which this user had before

    and press soft key ENTER. In the column Passwd it changes from YES to NO.

    Now it should be possible to login the original USER without entering a password.

    *) In case the soft key USERS does not appear continue toggling to the next installed USER until you get an

    USER with SYSTEM permission.

    Background information: Only a SYSTEM user is authorised to delete a password of any other USER and only

    he would have the soft key USER with the list of all the USER available.

    In case there is only one USER with SYSTEM permission available there would be no direct possibility for

    deleting the password.

    If this is fact please proceed by the following:1st possibility: Connect the PC to the Service-Port of the E-Box (Service connector on front of the E-Box

    controller RY 1917 or at rear side of the E-Box).

    Cable necessary 9pin

    pin2-------------pin2

    pin3-------------pin3

    pin5-------------pin5

    or 1:1 cable except pin7 and pin 9 connected

    necessary Software: MS-KERMIT or other Terminal emulation program (VT102; Hyper terminal)

    Please refer also to the Service manual 4.2 SERVICE MENU; Connecting a PC

    Call KERMIT.exe; type C for connect; push the SPACE pushbutton at the PC; the Service menu appears.Choose INTEGRATED ERROR DIAGNOSIS by typing I at the PC, then choose CLEAR RAM FILES by

    typing C and choose QUERY by typing Q. Now the first file which could be deleted would appear and you

    would be asked for clear process by YES or NO. Type ``Y`` for Yes (use capital letters otherwise your entry

    would be ignored) at the file named ACCESS; All other positions must be answered with ``N`` for No. The

    RAM content will be cleared at the position ACCESS, respectively set to default; Only the user COMMON with

    permission SYSTEM will appear. All other USER must be re-entered.

    2nd possibility is much more easier to carry out but with the result that more settings would be lost.

    It is to perform an "emergency clear ".

    Doing this by pressing the RESET switch on the E-box controller RY 1917. If

    all LEDs of the bar are lit, press the push button which is close to the RESET button

    (named MONITOR or 1TERM) and hold it down until the LEDs are running again in normal operation.

    ATTENTION; this would clear the file contents of: ACCESS, CONF-EB andSTATE-EB. The most important set-ups would be lost: Aux couple, Prerouter and DVE set-ups, port protocols,

    Genlock phase, Col-Limiter, EXTRA Define-memo.