514 West Maple Street, Suite 104 | Cumming, Georgia 30040 | (770) 888-8872 | forsythco.com Forsyth County Procurement Donna H. Kukarola, Director 4/19/19 ADDENDUM #1 BID 19-50-1620 For: Providing all materials, equipment and labor for restroom renovations at Hearthstone Lodge Community Center. This addendum supersedes and supplements all portions of the bidding documents and becomes part of the contract documents for the above-referenced project. Where any item called for in the specifications or indicated on the drawings is supplemented hereby, the original requirements shall remain in effect. Where any original item is amended, voided or superseded hereby, the provision of such item not so specifically amended, voided or superseded shall remain in effect. Clarifications from Mandatory Pre-Bid April 10, 2019: 1. Access is through the side door, reminder contractor is responsible for protection of flooring, walls from damage 2. Salvage wood slat walls as much as possible 3. Water fountain to be replaced – Sr. Center requested it by a hydration station type (to fill water bottles) 4. Confirmed electrical panel is one designated in place 5. Detail 2.5.1 – only one tile type T.1 for flooring and “wainscoting”, Type T-2 for sink areas 6. Hours of operation 7:00 am – 5:30 Monday, Wednesday, Friday; 7:00 am – 6:30 pm Tuesday and Thursday 7. Contractors had asked for either earlier hours or perhaps a Saturday – concern is over the noise for the users of the facility 8. Dumpster and laydown area will be designated in parking area 9. Fire Alarm – it is a strobe light notification

Upload: vuongtruc

Post on 12-Aug-2019

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Forsyth County Procurementbid-public.forsythco.com/BidDocs/Addendums/67f65a8f1e8342e89c7699722...Water fountain to be replaced – Sr. Center requested it by a hydration station type

514 West Maple Street, Suite 104 | Cumming, Georgia 30040 | (770) 888-8872 | forsythco.com

Forsyth County Procurement

Donna H. Kukarola, Director

4/19/19

ADDENDUM #1

BID 19-50-1620

For: Providing all materials, equipment and labor for restroom renovations at Hearthstone Lodge Community Center.

This addendum supersedes and supplements all portions of the bidding documents and becomes part of the contract documents for the above-referenced project. Where any item called for in the specifications or indicated on the drawings is supplemented hereby, the original requirements shall remain in effect. Where any original item is amended, voided or superseded hereby, the provision of such item not so specifically amended, voided or superseded shall remain in effect.

Clarifications from Mandatory Pre-Bid April 10, 2019:

1. Access is through the side door, reminder contractor is responsible for protection of flooring, walls from damage

2. Salvage wood slat walls as much as possible

3. Water fountain to be replaced – Sr. Center requested it by a hydration station type (to fill water bottles)

4. Confirmed electrical panel is one designated in place

5. Detail 2.5.1 – only one tile type T.1 for flooring and “wainscoting”, Type T-2 for sink areas

6. Hours of operation 7:00 am – 5:30 Monday, Wednesday, Friday; 7:00 am – 6:30 pm Tuesday and Thursday

7. Contractors had asked for either earlier hours or perhaps a Saturday – concern is over the noise for the users of the

facility

8. Dumpster and laydown area will be designated in parking area

9. Fire Alarm – it is a strobe light notification

Page 2: Forsyth County Procurementbid-public.forsythco.com/BidDocs/Addendums/67f65a8f1e8342e89c7699722...Water fountain to be replaced – Sr. Center requested it by a hydration station type

514 West Maple Street, Suite 104 | Cumming, Georgia 30040 | (770) 888-8872 | forsythco.com

Response to questions received (response in italics)

1. Do you want us to quote for whole building to be monitored of fire alarm? or only quote to install smoke detectors at

restroom?

Quote for smoke detectors in the restroom. Interpretation of the code is that since this is a renovation of a small

portion of the building, the entire building does not have to be brought up to code. Revision to drawing E-102 Note 5

to be sent at later date.

CHANGES TO THE DRAWINGS:

1-1 Sheet ID-2.51 FINISH PLAN AND ELEVATIONS: 1. Updated Elevations to show T-1 above showers 2. Added Alternate Add Equipment Schedule for EQ-1&EQ-2 Wood lockers 3. Reference attached sheet ID-2.51 revised under Addendum #1 dated April 19, 2019.

1-2 Sheet P001 PLUMBING LEGEND, NOTES & SCHEDULE:

1. Updated Plumbing Fixture Schedule P-6 Water Fountain specification 2. Reference attached sheet P001 revised under Addendum #1 dated April 19, 2019.

Page 3: Forsyth County Procurementbid-public.forsythco.com/BidDocs/Addendums/67f65a8f1e8342e89c7699722...Water fountain to be replaced – Sr. Center requested it by a hydration station type

UP

LIFE SAFETY PLAN LEGEND

SEPARATION PER IBC CHAPTER 5

CAPACITY PER LSC 7.3.3.1

DOORS = 0.2"/PERSON32"W DOOR = 30" CLR. = 150 CAPACITY36"W DOOR = 34" CLR. = 170 CAPACITY42"W DOOR = 40" CLR. = 200 CAPACITY48"W DOOR = 46" CLR. = 230 CAPACITY68"W DOOR = 64" CLR. = 320 CAPACITY72"W DOOR = 68" CLR. = 340 CAPACITY96"W DOOR = 92" CLR. = 460 CAPACITY

DOORS PER IBC 715.4

EXIT SIGNS PER IBC 1011

EXIT SIGNAGE (SHADING INDICATES FACE OF SIGN; ARROW SHOWN INDICATES DIRECTION)

ALLOWABLE DISTANCE PER LSC 12.2.6

TRAVEL DISTANCE LIMIT - MAX. 200 FT.

COMMON PATH LIMIT - MAX. 75 FT.

DEAD END LIMIT - MAX. 20 FT.

PATH OF EGRESS WITHIN BUILDING

TRAVEL DISTANCE & COMMON PATH (SEE NOTES ON PLANS)

NON-RATED PARTITION

LIFE SAFETY GENERAL NOTES

1. ALL WORK SHALL COMPLY WITH ALL STATE, CITY, AND LOCAL CODES, RULES, AND REGULATIONS. CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND INSPECTIONS ASSOCIATED WITH THIS WORK, AND SHALL PAY ALL COSTS AND FEES INVOLVED.

2. ALL ACCESSIBLE RESTROOMS MUST BE COMPLIANT WITH THE ADA AND OCGA 120-3-20A3. ENSURE ALL PIPING, MECHANICAL, AND ELECTRICAL HAVE THE PROPER FIRE-STOPPING MATERIALS.

A. 8.3.5.1 FIRESTOPPING SYSTEMS AND DEVICES REQUIRED. PENETRATIONS FOR CABLES, CABLE TRAYS, CONDUITS, PIPES, TUBES, COMBUSTIBLE VENTS AND EXHAUST VENTS, WIRES, AND SIMILAR ITEMS TO ACCOMMODATE ELECTRICAL, MECHANICAL, PLUMBING, AND COMMUNICATIONS SYSTEMS THAT PASS THROUGH A WALL, FLOOR, OR FLOOR/CEILING ASSEMBLY CONSTRUCTED AS A FIRE BARRIER SHALL BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE. THE FIRESTOP SYSTEM OR DEVICE SHALL BE TESTED IN ACCORDANCE WITH ASTM E 814, STANDARD TEST METHOD FOR FIRE TESTS OF

THROUGH PENETRATION FIRE STOPS, OR ANSI/UL 1470 STANDARD FOR FIRE TESTS OF THROUGH- PENETRATION FIRESTOPS, AT A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 IN WATER COLUMN (2.5N/M2) BETWEEN THE EXPOSED AND THE UNESPOSED SURFACE OF THE TEST ASSEMBLY.

4. THE PROVISIONS OF NFPA 241 (2000) STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, SHALL BE FOLLOWED. NOTE: SECTION 4.2.1 REQUIRES TEMPORARY ENCLOSURES (E.G. DUST BARRIERS) TO BE CONSTRUCTED USING NON-COMBUSIBLE, FLAME-RESISTANT, ETC. MATERIALS. THE USE OF POLYPROPYLENE PLASTIC OR SIMILAR COMBUSTIBLE MATERIALS (PLYWOOD, ETC.) TO ENCLOSE DEMOLITION WORK IS NOT PERMITTED BY THIS SECTION.

5. FIRE ALARM SYSTEMS SHALL BE PROTECTED DURING RENOVATIONS. 6. ALL REQUIRED MEANS OF EGRESS AND ALL REQUIRED FIRE PROTECTION FEATURES MUST BE IN PLACE AND CONTINUOUSLY

MAINTAINED FOR THE PORTION OF THE BUILDING BEING OCCUPIED DURING CONSTRUCTION, REPAIR, ALTERATION OR ADDITION IN ACCORDANCE WITH NFPA 101: 4.6.10.1, 2012 EDITION.

7. INTERIM FIRE PROTECTION BY FIRE EXTINGUISHERS TO BE PROVIDED DURING ALL WORK IN ACCORDANCE WITH NFPA 25 CHAPTER 14, 2012 EDITION.

BUILDING DATA

OCCUPANCY CLASSIFICATION: _______ASSEMBLY (NFPA CHPT. 3) GROUP A-3 (IBC CHPT 6)

TYPE OF CONSTRUCTION (IBC): ________RENOVATION, UNPROTECTED, UNSPRINKLERED

BUILDING AREAS (IBC):LEVEL 1 2,585 GSFTERRACE POOL LEVEL 3,982 GSFTOTAL AREA: 7,467 GSF

BUILDING OCCUPANCY (NFPA):LEVEL 1 25 PERSONSTERRACE LEVEL 79 PERSONSTOTAL: 104 PERSONS

RENOVATION AREA (TOILETS/SHOWERS):TOTAL: 375 GSF

INTERIOR WALL AND CEILING FINISH REQUIREMENTS (IBC TABLE 803.9):EXIT ENCLOSURES AND EXIT PASSAGEWAYS BCORRIDORS CROOMS AND ENCLOSED SPACES C

APPLICABLE CODES

2012 INTERNATIONAL BUILDING CODEWITH GEORGIA AMENDMENTS (2014)(2015)(2017)

2012 INTERNATIONAL FIRE CODEWITH GEORGIA AMENDMENTS (2014)

2012 INTERNATIONAL PLUMBING CODEWITH GEORGIA AMENDMENTS (2014)(2015)

2012 INTERNATIONAL MECHANICAL CODEWITH GEORGIA AMENDMENTS (2014)(2015)

2012 INTERNATIONAL FUEL GAS CODEWITH GEORGIA AMENDMENTS (2014)(2015)

2017 NATIONAL ELECTRICAL CODE(NO GEORGIA AMENDMENTS)

2009 INTERNATIONAL ENERGY CONSERVATION CODEWITH GEORGIA SUPPLEMENTS AND AMENDMENTS (2011)(2012)

2012 NFPA 101, LIFE SAFETY CODEWITH GEORGIA AMENDMENTS (2014)

2013 NFPA 72, NATIONAL FIRE ALARM & SIGNALING CODEWITH GEORGIA AMENDMENTS (2014)

2013 NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKERSYSTEMS WITH GEORGIA AMENDMENTS (2014)

2010 ADA STANDARDS, PER RULES AND REGULATIONS OF THESAFETY FIRE COMMISSIONER 120-3-20A

TRAVEL DISTANCE = 50'-0"

3330 Preston Ridge RD. Suite 380Alpharetta, GA 30005

2018,

Jeri

ch

o D

esig

n G

rou

p,

LL

C.

Th

ese d

raw

ing

s a

re p

rote

cte

d b

y t

he c

op

yri

gh

t la

ws o

f th

e U

nit

ed

Sta

tes.

Th

ese d

raw

ing

s o

r an

y p

art

th

ere

of

may

no

t b

e u

sed

fo

r an

y p

urp

ose o

r re

pro

du

ced

in

an

y f

orm

or

by

an

y m

ean

s w

ith

ou

t th

e w

ritt

en

co

nsen

t o

f D

ou

gS

haw

.

Sheet No.

Date

Sheet Title

Job No.

Drawn By Checked By

PRINT RECORD

RELEASED FOR CONSTRUCTION

1/2

3/2

019

1:5

0:2

8 P

M

C:\U

se

rs\w

rega

n\D

ocu

me

nts

\18

02

8_

DG

FO

CO

He

art

hsto

ne

_A

RC

H1

7_

wre

gan

@je

richo

-desig

n.c

om

.rvt

LS-1.01

LIFE SAFETY

01/14/2019 18028

TA/WR JDG

HE

AR

TH

ST

ON

E L

OD

GE

RE

ST

RO

OM

RE

NO

VA

TIO

N

FO

RS

YT

H C

OU

NT

Y

7305 L

AN

IER

DR

IVE

, C

UM

MIN

G G

A 3

0041

SCALE: 1/8" = 1'-0"

LIFE SAFETY PLAN1

No. DATE DESCRIPTION

01/14/2019 PERMIT SET

By David Heard at 11:30 am, Feb 20, 2019

Construction Access

Page 4: Forsyth County Procurementbid-public.forsythco.com/BidDocs/Addendums/67f65a8f1e8342e89c7699722...Water fountain to be replaced – Sr. Center requested it by a hydration station type

ID-2.51

ID-2.51

6

ID-2.51

3 7

2 4

9

8

T-1

T-1

WD-1WD-1

5

10

F-3

WOMEN'S

102

MEN'S

101

CORRIDOR

100

WD-1WD-1

48"AFF

T-2

T-2

3

ID-1.01

3

ID-1.01

T-1

48"AFF

T-1

48"AFF

T-1

T-1

48"AFF

24"ABOVE

COUNTER

24"ABOVE

COUNTER

T-1

ABOVE

PRE-FAB

SHOWER

T-1

ABOVE

PRE-FAB

SHOWER

T-1

ABOVE

PRE-FAB

SHOWER

T-1

ABOVE

PRE-FAB

SHOWER

F-3F-1

F-2

F-2 F-1F-2

F-1

F-1

F-3

F-2

F-1

F-2

F-2

F-3

2

ID-1.01

2

ID-1.01F-4

2' -

3"

5' - 0" 4' - 2"

7' -

1"

EQ-2

EQ-1

EQ-1

WD-1

T-1

WD-2

WD-3

TOP CAP

END CAP

WD-1

T-1

WD-2

2

ID-1.01

7' - 1"RELOCATED

LOCKERS N.I.C.

BENCH

PROVIDE

ALTERNATE ADD

TO PROVIDE NEW

PER ALTERNATE

ADD EQUIPMENT

SCHEDULE

TA-06

WD-1

T-1

4' - 2"

2

ID-1.01

TA-04

F-4

RELOCATED

LOCKERS N.I.C.

PROVIDE ALTERNATE ADD TO

PROVIDE NEW PER ALTERNATE

ADD EQUIPMENT SCHEDULE

OPEN

T-2

24" ABOVE

COUNTER

WD-2

TOP CAP

WD-1

COUNTERTOP &

APRON CLAD IN

SS-1

T-1

T-1

TO 48"AFF ON

ALL WALLS IN

STALLS, TYP.

ABOVE

SHOWERS

ON ALL

WALLS, TYP.

AT ALL

CORNERS

WD-2

T-2

24" ABOVE

COUNTER

P-2

WD-2

TOP CAP

WD-3

1

ID-1.01

WD-1

OPEN WD-2

AT ALL

CORNERS

SEE G1.01 FOR

MOUNTING

HEIGHTS

FINISH SYMBOL LEGEND

WALL FINISH

BASE FINISH

FLOOR FINISH

ACCENT WALL FINISH

FLOOR TRANSITION

FINISH PLAN KEY NOTES

FLOOR FINISH DIRECTION

F-#

CPT-4

P-3BB-2

P-4

T-3

COUNTERTOP &

APRON CLAD IN

SS-1

24"

ABOVE

COUNTER

T-1

P-2

AT ALL

CORNERS

WD-2

WD-2

WD-3

TOP CAP

1

ID-1.01

WD-3

WD-2

TA-06

F-4

EXISTING

LOCKERS,

N.I.C.

INTERIOR ELEVATION NOTES

1. GENERAL CONTRACTOR TO COORDINATE EQUIPMENT OUTLINED IN "EQUIPMENT

LEGEND" WITH OWNER & OWNER'S MEDICAL EQUIPMENT REPRESENTATIVE. THIS

INCLUDES VERTICAL AND HORIZONTAL MOUNTING HEIGHTS OF ALL DEVICES,

COORDINATION WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING. THE

ARCHITECT SHALL RECEIVE SHOP DRAWINGS SHOWING FINALIZED SELECTION OF

EQUIPMENT AND SPECIFICA MODEL NUMBERS REVIEWED BY DESIGN TEAM/ENGINEERS

PRIOR TO PROCEEDING WITH SCOPE OF WORK.

2. ELECTRICAL OUTLETS ARE ONLY SHOWN FOR COORDINATION WITH EQUIPMENT, SEE

ELECTRICAL DRAWINGS FOR MORE INFORMATION..

3. LOW VOLTAGE BY OWNE'S REPRESENTATIVE.

4. FURNITURE SHOWN IS TO BE PROVIDED BY OWNER U.N.O. GENERAL CONTRACTOR TO

COORDINATE WITH OWNER ON DELIVERY SCHEDULE.

3330 Preston Ridge RD. Suite 380Alpharetta, GA 30005

2018,

Jeri

ch

o D

esig

n G

rou

p,

LL

C.

Th

ese d

raw

ing

s a

re p

rote

cte

d b

y t

he c

op

yri

gh

t la

ws o

f th

e U

nit

ed

Sta

tes.

Th

ese d

raw

ing

s o

r an

y p

art

th

ere

of

may

no

t b

e u

sed

fo

r an

y p

urp

ose o

r re

pro

du

ced

in

an

y f

orm

or

by

an

y m

ean

s w

ith

ou

t th

e w

ritt

en

co

nsen

t o

f D

ou

gS

haw

.

Sheet No.

Date

Sheet Title

Job No.

Drawn By Checked By

PRINT RECORD

RELEASED FOR CONSTRUCTION

4/1

8/2

019

4:1

6:0

9 P

M

C:\U

se

rs\w

rega

n\D

ocu

me

nts

\18

02

8_

DG

FO

CO

He

art

hsto

ne

_A

RC

H1

7_

wre

gan

@je

richo

-desig

n.c

om

.rvt

ID-2.51

FINISH PLAN &ELEVATIONS

01/14/2019 18028

TA/WR JDG

HE

AR

TH

ST

ON

E L

OD

GE

RE

ST

RO

OM

RE

NO

VA

TIO

N

FO

RS

YT

H C

OU

NT

Y

7305 L

AN

IER

DR

IVE

, C

UM

MIN

G G

A 3

0041

SCALE: 3/8" = 1'-0"

RESTROOM FINISH PLAN1

SCALE: 3/8" = 1'-0"

MEN'S NORTH ELEV7

SCALE: 3/8" = 1'-0"

MEN'S EAST ELEV8 SCALE: 3/8" = 1'-0"

MEN'S SOUTH ELEV9

SCALE: 3/8" = 1'-0"

WOMEN'S WEST ELEV2

SCALE: 3/8" = 1'-0"

WOMEN'S NORTH ELEV3

SCALE: 3/8" = 1'-0"

WOMEN'S EAST ELEV4SCALE: 3/8" = 1'-0"

FOUNTAIN ELEV6

KEY NOTES - FINISH PLAN

KEY

NOTE # DESCRIPTION

F-1 WALL TRANSITION - END DETAIL. SEE 5/ID-1.01

F-2 WALL TRANSITION - CORNER DETAIL. SEE 4/ID-1.01

F-3 WALL TRANSITION - WOOD TO TILE TOP DETAIL. SEE 6/ID-1.01

F-4 MODIFIED BENCH PER NEW DIMENSIONS. REFER TO DETAIL 2/ID-1.01. FINISH NEW

CUT ENDS TO MATCH EXISTING.

SCALE: 3/8" = 1'-0"

MEN'S WEST ELEV10

SCALE: 3/8" = 1'-0"

WOMEN'S SOUTH ELEV5

No. DATE DESCRIPTION

01/14/2019 PERMIT SET

A 04/19/2019 ADDENDUM 1

A

A

A

ALTERNATE ADD EQUIPMENT SCHEDULE (EQ-)

TAG NO. DESCRIPTION Manufacturer Model

FURNISHED BY INSTALLED BY

NOTESCONTRACTOR OWNER CONTRACTOR OWNER

EQ-1 3 WIDE DOUBLE TIER -

CHARCOAL OAK

ALL WOOD

LOCKERS

SWF12 2T

3W CO

X X ADD SIDE PANEL

SW CO

EQ-2 1 WIDE DOUBLE TIER -

CHARCOAL OAK

ALL WOOD

LOCKERS

SWF12 2T

1W CO

X X

A

A

Page 5: Forsyth County Procurementbid-public.forsythco.com/BidDocs/Addendums/67f65a8f1e8342e89c7699722...Water fountain to be replaced – Sr. Center requested it by a hydration station type

GENERAL PLUMBING NOTESALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH THE 2012 INTERNATIONAL PLUMBING CODE WITH GEORGIA STATE AMENDMENTS, ALL LOCAL CODES AND ALL OTHER REGULATIONS GOVERNING WORK OF THIS NATURE

THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK MATERIALS AND LABOR TO SATISFY A COMPLETE AND WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED.

THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ALL FEES AS REQUIRED.

THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE THE CONDITIONS THAT MAY EFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS.

WASTE AND VENT PIPING

A. ABOVE GROUND

1.

2.

3.

4.

5.

CEILINGS, OR FLOORS.SHALL NOT CROSS FIRE RATED WALLS,IN THE AIR PLENUM CEILINGS AND

NOTE: PVC PIPING SHALL NOT BE USED

SOLVENT JOINTS.AND SPIGOT JOINTS OR SCH. 40 PVC WITHSERVICE WT. CAST IRON WITH BELL

B: BELOW GRADE:

PVC WITH SOLVENT JOINTS.OR BELL AND SPIGOT JOINTS; OR SCH. 40

- 3" AND LARGER: SERVICE WT. CAST IRON WITH NO-HUB

JOINTS OR DWV COPPER WITH SOLDER JOINTS.ENDS OR SCH. 40 PVC WITH SOLVENT

- 2" AND BELOW: SCH. 40 GALV. STL. PIPE WITH SCREWED

DOMESTIC WATER PIPING

A. UNDERGROUND: PROVIDE TYPE "K" SOFT DRAWN COPPER TUBING WITH BRAZED CONNECTIONS

B: ABOVE GROUND: PROVIDE TYPE "L" HARD DRAWN TUBING WITH 125 PSI SOLDER JOINTS, COPPER OR BRASS FITTINGS

6.

DRAINAGE PIPING SHALL RUN STRAIGHT AS POSSIBLE AND SHALL HAVE LONG TURN FITTINGS.

DRAINAGE PIPING 3" DIAMETER AND SMALLER SHALL BE RUN AT UNIFORM SLOPE OF AT LEAST 1/4" PER FOOT, AND PIPING LARGER THAN 3" SHALL BE RUN AT A SLOPE OF NO LESS THAN 1/8" PER FOOT.

ALL VENT PIPING SHALL BE SLOPED TO DRAIN BACK TO FIXTURES.

ALL STUB-INS AND/OR SLAB OR WALL PENETRATIONS TO BE PER NFPA 20 SECTION 2-11.1 AND 1.2-11.1. ALL PIPING PENETRATIONS OF BUILDING FOUNDATIONS OR FOOTINGS SHALL BE SLEEVED.

PLUMBING SYSTEM SHALL BE FLOW AND PRESSURE TESTED IN ACCORDANCE WITH STANDARD PRACTICE AND THE 2012 IPC.

PIPING SUPPORTS (ABOVE GRADE) ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE AND PREFORMED METAL TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL BE AS SPECIFIED IN MSS SP-69.

PIPING SUPPORTS (BELOW GRADE) EARTH SHALL BE EXCAVATED TO A MINIMUM DEPTH WITH AN EVEN SURFACE TO INSURE SOLID BEARING OF PIPE FOR ITS ENTIRE LENGTH.

NEW HOT WATER PIPING TO BE INSULATED WITH 1" FIBERGLASS INSULATION. NEW COLD WATER PIPING TO BE INSULATED WITH 1/2" FOAM INSULATION.

PROVIDE SHUTOFF VALVES AT ALL FIXTURES, BOTH HOT AND COLD. AT SHOWERS, LOCATE SHUT OFF VALVE ABOVE LAY IN CEILING ADJACENT TO SHOWERS BEING SERVED IN THE SAME ROOM.

7.

8.

9.

10.

11.

12.

13.

14.

15.

P-1

MARK DESCRIPTION

WATER CLOSET -FLOOR MOUNT

MANUFACTURER & CATALOG NO.

AMERICAN STANDARD CHAMPTON PRO

WASTECONNECTION

CWCONNECTION

HWCONNECTION

VENTCONNECTION

3" 1-1/2" - 2"

FLOOR MOUNTED, TANK TYPE, 1.28 GPF FLUSH, COMFORT HEIGHT, ELONGATED WHITE VITREOUS CHINA. PROVIDE WITH OPEN-FRONT SEAT, FLUSH HANDLE TO BE ON WIDE SIDE OF STALL.

COMMENTS

PLUMBING FIXTURE SCHEDULE

P-1H WATER CLOSET -FLOOR MOUNT-ADA 3" 1-1/2" - 2"

P-2 URINAL - ADA AMERICAN STANDARD6002.525

2" 3/4" - 1-1/2"

WHITE VITREOUS CHINA, ADA COMPLIANT, MAXIMUM 17" FROM FLOOR TO RIM, 0.125 GPF, 2" OUTLET SPUD, PROVIDE WITH STRAINER, WALL HANGER AND ACCESSORIES AS NEEDED FOR A COMPLETE INSTALLATION. SELECTRONIC FLUSH VALVE WITH BATTERY OPERATED SENSOR. WITH MANUAL OVERRIDE BUTTON.

P-4 LAVATORYUNDERMOUNT

KOHLER K-2611-SU 1-1/2" 1-1/4"

UNDERMOUNT, 20-GAUGE STAINLESS STEEL OVAL BASIN, 11-3/4" X 16-3/4". PROVIDE WITH COUNTER MOUNTED FAUCET EQUAL TO AMERICAN STANDARD SELECTRONIC WITH PLUG IN POWER ADAPTER AND 0.5 GPM AERATOR AND GRID STRAINER. PROVIDE TEMPERING VALVE EQUAL TO TACO 5120 TO MAINTAIN 110°F OR LESS TO LAVATORY.

P-6 WATER FOUNTAIN ELKAY LZSTL8WSLP 1-1/4" 1/2" - 1-1/4"WALL MOUNTED HI-LOW WATER FOUNTAIN WITH FRONT/SIDE TOUCH PADS, 8 GPH CAPACITY, 50°F SUPPLY WATER, ADA COMPLIANT WITH BOTTLE FILLER.

P-5 SHOWERDELTA - CLASSIC 400AMERICAN STANDARD - RELIANT 3

ACRYLIC SHOWER 36" X 36" OUTSIDE DIMENSIONS WITH TEXTURED BOTTOM, WEIGHTED SHOWER CURTAIN. PROVIDE WITH SHOWER TRIM EQUAL TO AMERICAN STANDARD RELIANT 3 LESS DIVERTER TUB SPOUT, WITH PRESSURE BALANCED MIXING VALVE WITH HIGH TEMP LIMIT STOP AND INTEGRATED CHECK VALVES TO ELIMINATE CROSS FLOW.

2" 1/2" 1/2" 1-1/2"

P-5H SHOWER - ADA 2" 1/2" 1/2" 1-1/2"

BARRIER FREE THRESHOLD WITH REINFORCED SHOWER BASE. 38.6" X 38.4" OUTSIDE DIMENSIONS WITH GRAB BARS, FOLDING SHOWER SEAT, WEIGHTED SHOWER CURTAIN. PROVIDE WITH SHOWER TRIM EQUAL TO AMERICAN STANDARD RELIANT 3 LESS DIVERTER TUB SPOUT, WITH PRESSURE BALANCED MIXING VALVE WITH HIGH TEMP LIMIT STOP AND INTEGRATED CHECK VALVES TO ELIMINATE CROSS FLOW.

FREEDOM - APF3838BF4P.5AMERICAN STANDARD - RELIANT 3

FLOOR MOUNTED, TANK TYPE, 1.28 GPF FLUSH, COMFORT HEIGHT, ELONGATED WHITE VITREOUS CHINA. PROVIDE WITH OPEN-FRONT SEAT, FLUSH HANDLE TO BE ON WIDE SIDE OF STALL.

AMERICAN STANDARD CHAMPTON PRO

1/2" 1/2"

EXISTING PIPING - EX

SANITARY, WASTE ABOVE FLOOR - S, W, SAN

STORM BELOW FLOOR - ST

VENT PIPING - V

COLD WATER PIPING - CW

HOT WATER PIPING - HW

CLEANOUTS - CO, WCO, FCO, GCO

GATE VALVE - GV

BALL VALVE - BV

FLOOR DRAIN - FD

ABOVE CEILING

ABOVE FLOOR

BELOW FLOOR

BELOW GRADE

CONDENSATE DRAIN

CLEAN OUT

COLD WATER

DOWN

DOWNSPOUT NOZZLE

EMERGENCY ROOF DRAIN / LEADER

EMERGENCY ROOF DRAIN WATER

FLOOR CLEANOUT

FLOOR DRAIN

HOT WATER

HOT WATER CIRCULATING

INSTANTANEOUS WATER HEATER

NONFREEZE WALL HYDRANT

PLUMBING FIXTURE

PLUMPED DISCHARGE

ROOF DRAIN

ROOF DRAIN LEADER

RAIN WATER

VENT

VENT THROUGH ROOF

WASTE

WALL CLEANOUT

A/C

A/F

B/F

B/G

CD

CO

CW

DN

DSN

ERL

ERW

FCO

FD

HW

HWC

IWH-1

NFWH

P-*

FP

RD

RL

RW

V

VTR

W

WCO

PLUMBING LEGEND

NOTE: EVERY SYMBOL AND ABBREVATION MAY NOT BE USED ON THIS PROJECT

3330 Preston Ridge RD. Suite 380Alphretta, GA 30005

2018

, Jer

icho

Des

ign

Gro

up, L

LC. T

hese

dra

win

gs a

re p

rote

cted

by

the

copy

right

law

s of

the

Unite

d St

ates

. The

se d

raw

ings

or a

ny p

art t

here

of m

ay n

ot b

e us

ed fo

r any

pur

pose

or r

epro

duce

d in

any

form

or b

y an

y m

eans

with

out t

he w

ritte

n co

nsen

t of D

oug

Shaw

.

Sheet No.

Date

Sheet Title

Job No.

Drawn By Checked By

PRINT RECORD

FOR CONSTRUCTION

GEI PROJECT # 18162

4/18

/201

9 4:

00:2

1 P

MC

:\Use

rs\jm

ccut

cheo

n\D

ocum

ents

\Rev

it Lo

cal M

odel

s\18

162

- Hea

rthst

one

Cen

tral M

odel

R17

_grif

fithe

ng.rv

t

P001

PLUMBING LEGEND,NOTES, & SCHEDULE

01/14/2018 18028

GAW Checker

HEAR

THST

ONE

LO

DGE

REST

ROO

M R

ENO

VATI

ON

FORS

YTH

COUN

TY

7305

LAN

IER

DR

IVE,

CU

MM

ING

GA

3004

1

No. DATE DESCRIPTION1/14/2019 PERMIT SET

A 04/19/2019 ADDENDUM 1

A A