frequency converter m-max - reykjafell | lausnir í ... · pdf filepowerware ®,...

Download Frequency converter M-Max - Reykjafell | Lausnir í ... · PDF filePowerware ®, Holec ®, MEM , Santak and ... duplicated or distributed by means of electronic systems without

If you can't read please download the document

Upload: trinhkhanh

Post on 08-Feb-2018

231 views

Category:

Documents


13 download

TRANSCRIPT

  • Frequency converterM-Max

    Bed

    ien

    un

    gsh

    and

    bu

    ch

    Moeller addresses worldwide:www.moeller.net/address

    E-Mail: [email protected]: www.moeller.net

    Issued by: Moeller GmbHHein-Moeller-Str. 711D-53115 Bonn

    2009 by Moeller GmbHSubject to alterationAWB8230-1604en PB/PB/Eb 12/08Printed in the Federal Republic of Germany (02/09)Article No.: xxxxxx

    Eaton's electrical business is a global leader in electrical control, power distribution, uninterruptible power supply and industrial automation products and services. Eaton's global electrical brands, including Cutler-Hammer, MGE Office Protection Systems, Powerware, Holec, MEM, Santak and Moeller, provide customer-driven PowerChain Management solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical and OEM markets worldwide.www.eaton.com

    06/09 AWB8230-1603en

    A

    R

    cken

    bre

    ite

    bis

    10

    mm

    (1

    Bla

    tt =

    0,1

    06 m

    m f

    r

    XB

    S D

    igit

    ald

    ruck

    )(1

    Bla

    tt =

    0,0

    80 m

    m f

    r

    Eber

    wei

    n D

    igit

    ald

    ruck

    bei

    80

    g/m

    2 )

    User Manual

  • All brand and product names are trademarks or registered trademarks of the owner concerned.

    1st edition 2009, edition date 06/09

    2009 by Moeller GmbH, 53105 Bonn

    Author: Jrg RandermannProduction: Ren WiegandTranslation: globaldocs GmbH

    All rights reserved, including those of the translation.

    No part of this manual may be reproduced in any form (printed, photocopy, microfilm or any other process) or processed, duplicated or distributed by means of electronic systems without written permission of Moeller GmbH, Bonn.

    Subject to alteration without notice.

    R

    cken

    bre

    ite

    fest

    leg

    en!

    (1 B

    latt

    = 0

    ,106

    mm

    , gilt

    nu

    r f

    r X

    BS)

    (1 B

    latt

    = 0

    ,080

    mm

    f

    r Eb

    erw

    ein

    Dig

    ital

    dru

    ck b

    ei 8

    0 g

    /m2 )

  • I

    Before commencing the installation

    Disconnect the power supply of the device.

    Ensure that devices cannot be accidentally restarted.

    Verify isolation from the supply.

    Earth and short circuit.

    Cover or enclose neighbouring units that are live.

    Follow the engineering instructions (AWA) of the device concerned.

    Only suitably qualified personnel in accordance with EN 50110-1/-2 (VDE 0105 Part 100) may work on this device/system.

    Before installation and before touching the device ensure that you are free of electrostatic charge.

    The functional earth (FE) must be connected to the protective earth (PE) or to the potential equalisation. The system installer is responsible for implementing this connection.

    Connecting cables and signal lines should be installed so that inductive or capacitive interference does not impair the automation functions.

    Install automation devices and related operating elements in such a way that they are well protected against unintentional operation.

    Suitable safety hardware and software measures should be implemented for the I/O interface so that a line or wire breakage on the signal side does not result in undefined states in the automation devices.

    Ensure a reliable electrical isolation of the low voltage for the 24 volt supply. Only use power supply units complying with IEC 60364-4-41 (VDE 0100 Part 410) or HD 384.4.41 S2.

    Deviations of the mains voltage from the rated value must not exceed the tolerance limits given in the specifications, otherwise this may cause malfunction and dangerous operation.

    Emergency stop devices complying with IEC/EN 60204-1 must be effective in all operating modes of the automation devices. Unlatching the emergency-stop devices must not cause restart.

    Devices that are designed for mounting in housings or control cabinets must only be operated and controlled after they have been installed with the housing closed. Desktop or portable units must only be operated and controlled in enclosed housings.

    Moe

    llerG

    mbH

    Safe

    ty in

    stru

    ctio

    nsDanger! Dangerous electrical voltage!

  • II

    Measures should be taken to ensure the proper restart of programs interrupted after a voltage dip or failure. This should not cause dangerous operating states even for a short time. If necessary, emergency-stop devices should be implemented.

    Wherever faults in the automation system may cause damage to persons or property, external measures must be implemented to ensure a safe operating state in the event of a fault or malfunction (for example, by means of separate limit switches, mechanical interlocks etc.).

  • 06/09 AWB8230-1603en

    Contents

    About This Manual 5Writing Conventions 5Abbreviations and Symbols 6 Units 6

    1 M-Max Series 7System overview 7Checking the Delivery 8Rating and Rating Plate 9 Key to part numbers 10 General rated operational data 12 Technical data 14M-Max Designation 16Features 17Selection criteria 18Proper use 20Maintenance and inspection 20Service and warranty 20

    2 Engineering 21Introduction 21Electrical power network 22 Mains connection and configuration 22 Mains voltage and frequency 22 Voltage balance 22 Idle power compensation devices 23 Mains reactors 23Safety and switching 24 Fuses and cable cross-sections 24 Cables and fuses 24 Residual-current device 24 Mains contactor 25EMC measures 26Motor and Application 27 Motor selection 27 Connecting motors in parallel 27 Motor and circuit type 28 Bypass operation 29 Connecting EX motors 29

    1

  • Contents 06/09 AWB8230-1603en

    3 Installation 31Introduction 31Installation guidelines 31 Mounting position 31 Cooling measures 31 Fixing 32EMC-compatible installation 35 EMC measures in the control panel 35 Earthing 35 Shielding 35Electrical Installation 37 Power section connections 38 Arrangement and connection of the power terminals 40 Connection on control section 41 Arrangement and connection of the control signal

    terminals 42 Function of the control signal terminals 43 Block diagram 48 Insulation testing 50

    4 Operation 53Checklist for commissioning 53Hazard warnings 54Commissioning with control signal terminals (factory setting) 55 Brief Instructions 58

    5 Error and Warning Messages 61Introduction 61 Error messages 61 Fault log (FLT) 61 Alarm messages 61

    6 Parameters 65Control unit 65 Display unit 66 General information on menu navigation 66 Setting parameters 67Parameter menu (PAR) 69 Parameter selection (P1) 71 Analog input (P2) 73 Digital input (P3) 76 Analog output (P4) 79 Digital output (P5) 80 Drives control (P6) 81 Motor (P7) 85 Protective functions (P8) 87 PI controller (P9) 90 Fixed frequency setpoint value (P10) 92 U/f-characteristic curve (P11) 94 Braking (P12) 97 System parameter 100Operational data indicator (MON) 102Setpoint input (REF) 104

    2

  • 06/09 AWB8230-1603en Contents

    7 Serial interface (Modbus RTU) 105Introduction 105 Operating mode Modbus RTU 107 Modbus Process Data 108 Output process data 108 Input process data 108 Bit Definition 109

    Appendix 111Special technical data 111Dimensions and frame size 114Cables and fuses 116Mains contactors 118 Mains reactors 119 Motor reactors 121List of parameters 123 Quick configuration (basis) 123 All Parameters 125

    Index 133

    3

  • 06/09 AWB8230-1603en

    4

  • 06/09 AWB8230-1603en

    About This Manual

    This manual provides a description of the frequency inverters of the M-Max series. It provides special information required for project planning, installation and for the operation of the MMX frequency inverter. All information applies to the specified hardware and software versions.

    Please read the manual thoroughly before you install and operate the frequency inverter.

    We assume that you have a good knowledge of engineering fundamentals and that you are familiar with handling electrical systems and machines, as well as with reading technical drawings.

    Writing Conventions

    The symbols used in this manual have the following meanings:

    X Indicates instructions to be followed

    In order to make it easier to follow the manual, the name of the current chapter is shown in the header of the left-hand page and the name of the current section is shown in the header of the right-hand page. This does not apply to pages at the start of a chapter or to empty pages at the end of a chapter.

    h Indicates useful tips and additional information.

    h Caution!Warns about the possibility of minor property damage.

    i Warning!Warns about the possibility of serious property damage and minor injuries.

    j Danger!Warns about the possibility of major property damage and serious injuries or death.

    h In order to make it easier to understand some of the figures included in this manual, the housing of the frequency inverter, as well as other safety-relevant parts, have been left out. However, it is important to note that the frequency inverter must always be operated with its housing placed properly, as well as with all required safety-relevant parts.

    h Please follow the installation instructions in the AWA8230-2416 installation instructions document.

    h This manual was created in an electronic format. You can also order a hard copy version of it.

    h All the specifications in this manual refer to the hardware and software versions documented in it.

    h More info