    FRESH AIR INTAKE

    LOUVERS

  • 7/31/2019 Fresh Air Intake

    2/7

    CAT DUCT PRODUCT RANGE

    GI Rectangular Ducting

    GI Spiral Ducting

    Aluminum Ducting

    Stainless Steel Ducting

    Black Steel Ducting Fire Rated Ducting

    Rectangular Volume Control Dampers ( GI & SS )

    Round Volume Control Dampers ( GI, SS & AL )

    Fire Dampers

    Air Filters

    Access Doors

    VAV

    Sound Attenuators Back Draft Dampers

    Metal Cladding ( AL & SS )

    Fresh Air Intake Assembly

    S.S. Kitchen Equipments

    CAT DUCT PRODUCTS ARE WIDELY APPROVED

    AND USED IN QATAR INCLUDING PROJECTS FOR

    KAHRAMAA, ASHGHAL, PEARL QATAR ETC.

  • 7/31/2019 Fresh Air Intake

    3/7

    Description

    The frame and blades are of high quality extruded aluminium profile construction with the advantagesof corrosion resistance and rigidity

    Composed of two sets of inverted U - channels mounted vertically on two opposite rows

    Drain holes of 20mm diameter are provided in two rows at the bottom of the louver for emptying

    filtered sand and dust

    Can be manufactured from galvanized steel sheets

    Designed to separate sand and dust from the air steam

    Generally used for ventilation application and at inlet duct of air handling unit

    Standard finishes

    Natural aluminium anodized finish

    Finish as per RAL colour codes

    Flexibility of finishing available as an option

  • 7/31/2019 Fresh Air Intake

    4/7

    FRESH AIR LOUVER FOR EXTERNAL

    AIR INTAKE APPLICATION

    SAND TRAP LOUVER FOR EXTERNAL

    AIR INTAKE APPLICATION

    Description

    Louvers are designed for both intake and exhaust air service

    in commercial applications.

    Total structure is weather proof and blades are inclined

    downwards to protect against rainwater. The fresh air louver

    is used to allow fresh clean air to the air handling units.

    Construction

    Fresh Air Louvers casing /frame is manufactured from

    extruded aluminium.

    Blades are inclined at 45 on 45mm blade pitch centre to

    minimize water ingress.

    Insect screen will be fitted at the backside to protect entering

    of insects.

    Insulating gasket is fixed around the back of the frame to

    prevent infiltration between the louver frame and casing.

    Frame & Louver: Aluminium Extrusion

    Insert Screen: Galvanized Steel Mesh

    Optional: GI 20 GA Frame & Blades

    Description

    The sand trap Louver is used as prefilter for the protection of

    air conditioning plants in areas exposed to extreme levels of

    industrial pollution. It has high degrees of separation of

    sand and large dust concentrations. The vertically arranged

    sections and open for sand drainage ensure that the sand

    trap louver is self-cleaning and maintenance free.

    Construction

    Sand trap Louvers with vertical slots are designed to separate

    dust and sand from air stream. It will separate 80 percentage

    of solid particles retained in the atmosphere.

  • 7/31/2019 Fresh Air Intake

    5/7

    ALUMINIUM FILTER FOR EXTERNAL

    AIR INTAKE APPLICATION

    DescriptionAluminium filters are permanent filters with layers of

    aluminium slit and expanded into mesh of differing

    densities, encased in galvanized steel frame.

    Aluminium filters are permanent filters and are washable

    type panel filters made up of 9 ply aluminium filter media

    in single layer or two layers encased in galvanized steel

    frame.

    Construction

    Filter outer casing made from GI sheet of 1.2mm thickness.

    One end of casing closed with a door by which we can

    remove filter for cleaning purpose.

    Door fixed with Piano Hinges and door locked by means

    of cam lock arrangement.

    Outer Casing with 25mm flange outside made up of GI

    18 Ga.

    Filter Frame: GI 22 Ga Thickness

    Optional: Aluminium Extrusion

    The frame and baffles are made from 1.0 mm (20 Ga) thickness

    GI Sheet. Construction allows air stream pass through thevertical restriction where all the sand particles falling down-

    wards are collected in a tray.

    Outer Casing with 25mm flange outside allows STL to be

    assembled along with louver and filter sections.

    Vertical Frame: GI 20 Ga Thickness

    Optional: Aluminium Extrusion

    Outer Casing: GI 18 Ga Thickness

    Vertical Frames

    Outer Casing

    Sand Collecting Tray

    Washable Filter Media

    Outer Casing

  • 7/31/2019 Fresh Air Intake

    6/7

    SAND TRAP LOUVER

    WITH BIRD SCREEN

    ConstructionFrame and blades:

    1.5mm and 1.2mm thick high quality extruded aluminium

    profiles.

    Bird screen

    12mm x 12mm x 1.5mm dia aluminium wire mesh as

    standard.

    12mm x 12mm x 1mm dia G.I. wire mesh as optional.

    Drain20mm dia self drain holes at the bottom of the louver.

    Description

    Polyfiber CPFRT20 model filters are flat type panel filters

    made up of G2/G3/G4 or F5 grade synthetic filter media.

    In this type the filter media pad is encased in a metallic

    frame (galvanized steel), bonded properly to ensure a

    leak-free operation. A wire mesh having 98% open area

    is provided on the upstream and down stream which

    reinforces and supports the filter media.

    Construction

    Filter outer frame made from GI sheet of 1.0mm thickness.

    Filter media encased by 12mm x 12mm galvanized metallic

    frame.

    Above the size of 800mm, a separate reinforcement strip

    will be provided to strengthen the structure.

    Generally high efficiency filter comes next to the aluminium

    washable filter.

    High Efficiency Filter

    Polyfibre with wiremesh

    HIGH EFFICIENCY FILTER FOR

    EXTERNAL AIR INTAKE

    APPLICATION

  • 7/31/2019 Fresh Air Intake

    7/7