from the desk of managing director · h.o. and service center contact person phone no. (o) mobile...

8
OCTOBER 2019 AN ISO 9001 : 2015 COMPANY Training Calendar Piyush Patel (M.D.) Motor Control AN ISO 9001 : 2015 COMPANY Amtech Power Official News Letter of Amtech Electronics (India) Ltd., Gandhinagar, Gujarat (India) OT-iB Series OT-iB Series Energy saving in Back Water Pump From the Desk of Managing Director Our Values A popular speaker started off a seminar by holding up a Rs 500 note. A crowd of 200 had gathered to hear him speak. He asked, “Who would like this Rs 500 note?” 200 hands went up. He said, “I am going to give this Rs 500 note to one of you but first, let me do this.” He crumpled the currency note up. He then asked, “Who still wants it?” All 200 hands were still raised. “Well,” he replied, “What if I do this?” Then he dropped the currency note on the ground and stomped on it with his shoes. He picked it up, and showed it to the crowd. The currency note was all crumpled and dirty. “Now who still wants it?” All the hands still went up. “My friends, I have just showed you a very important lesson. No matter what I did to the money, you still wanted it because it did not decrease in value. It was still worth Rs 500. Many times in our lives, life crumples us and grinds us into the dirt. We make bad decisions or deal with poor circumstances. We feel worthless. But no matter what has happened or what will happen, We will never lose our value. We are special – Don’t ever forget it!” Product Overview “There are two ways of spreading light: to be the candle or to be the mirror that reflects it." MEET US at Stall No - 5170 Lane-E & F 3-6 December 2019 Pragati Maidan, New Delhi 3-6 December 2019 Pragati Maidan, New Delhi JK PAPER LTD. Customer’s Voice Techno-Talk What is Harmonic Mitigation? Substation Automation Best wishes for - Mathatma Gandhi Jayanti - Dussehra - Diwali - New year - Sardar Jayanti - AMTECH FAMILY Customer’s Voice Aashirwad Pulp and Paper Mills

Upload: others

Post on 23-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

OCTOBER 2019

AN ISO 9001 : 2015 COMPANY

Training Calendar

Piyush Patel (M.D.)

Motor Control

AN ISO 9001 : 2015 COMPANY

Amtech Power

Official News Letter of Amtech Electronics (India) Ltd., Gandhinagar, Gujarat (India)

OT-iB Series

OT-iB Series

Electronics Soft-Starter

MODENORM

ESC UP

DOWN ENTER

GROUP

STOPRESET

FAULT

RUN

Electronics Soft-Starter

MODENORM

ESC UP

DOWN ENTER

GROUP

STOPRESET

FAULT

RUN

Energy saving in Back Water Pump

From the Desk of Managing DirectorOur ValuesA popular speaker started off a seminar by holding up a Rs 500 note. A crowd of 200 had gathered to hear him speak. He asked, “Who would like this Rs 500 note?” 200 hands went up.He said, “I am going to give this Rs 500 note to one of you but first, let me do this.” He crumpled the currency note up. He then asked, “Who still wants it?” All 200 hands were still raised.“Well,” he replied, “What if I do this?” Then he dropped the currency note on the ground and stomped on it with his shoes.

He picked it up, and showed it to the crowd. The currency note was all crumpled and dirty.“Now who still wants it?” All the hands still went up.“My friends, I have just showed you a very important lesson. No matter what I did to the money, you still wanted it because it did not decrease in value. It was still worth Rs 500. Many times in our lives, life crumples us and grinds us into the dirt. We make bad decisions or deal with poor circumstances. We feel worthless. But no matter what has happened or what will happen, We will never lose our value. We are special – Don’t ever forget it!”

Product Overview

“There are two ways of spreading

light: to be the candle or to be the mirror that

reflects it."

MEET US

at Stall No - 5170Lane-E & F

3-6 December 2019 Pragati Maidan, New Delhi3-6 December 2019 Pragati Maidan, New Delhi

JK PAPER LTD.Customer’s Voice

Techno-TalkWhat is

Harmonic Mitigation?

Substation Automation

Best wishes for - Mathatma Gandhi Jayanti

- Dussehra- Diwali

- New year- Sardar Jayanti

- AMTECH FAMILY

Customer’s VoiceAashirwad Pulp and Paper Mills

Page 2: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

TRAINING CALENDAR

201920192019201920192019201920192019202020202020

25-2623-2420-2125-2622-2319-2017-1821-2219-2023-2424-2519-20

+AXPERT-EAZYSERIES VFD

Active Static VAR Compensator

Active Front-end Converter

Active Harmonic Filter

Electronics Soft-Starter

MODENORM

ESC UP

DOWN ENTER

GROUP

STOPRESET

FAULT

RUN

OT-iB Series

Electronics Soft-Starter

MODENORM

ESC UP

DOWN ENTER

GROUP

STOPRESET

FAULT

RUN

OT-iB Series

Active Static VAR Compensator

AXPERT- Series ENGINEERED SYSTEMS

Active Harmonic FilterActive Front-end Converter

Product training module: About Amtech VFD and AC Motor fundamentals Physical familiarity of VFD and Soft Starter Understanding the specifications, different models, selecting the proper rating and options provided for VFD and Soft Starter Installation and Commissioning of VFD and Soft Starter Understanding of different applications of VFD and Soft Starter Trouble shooting of VFD and Soft Starter

TM Drive support software Axpert - Communicator for PC

Product Portfolio:

Page 3: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

3

TECHNO-TALK

In simple terms, harmonics are extra frequencies that when present in an electrical circuit, distort the AC sine wave. A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency.For example, if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc. Harmonic frequencies are equally spaced by the width of the fundamental frequency and can be found by repeatedly adding that frequency. In India, the fundamental frequency of electric supply is 50 Hz. The frequencies of the harmonics are 100 Hz, 150 Hz, 200 Hz, 250 Hz, 300 Hz, 350 Hz and so on. 150 Hz is called the 'third' harmonic (3 x 50 Hz), 250 Hz is called the 'fifth' harmonic (5 x 50 Hz), etc. The presence of harmonics in an electrical system distorts the clean shape of a sine wave.How do you know if you have harmonics in your electrical system?If you occasionally experience some unexplained occurrences such as flickering lights, alarms going off, or MCB's, MCCB's, RCD's and Earth Leakage devices tripping for no apparent reason, you are most likely experiencing harmonics in your electrical environment. Other signs are cables running hot, hot switchboards or overheating motors. If you are replacing your motor's bearings & insulation often, that's a strong indication of the presence of harmonics.What are the effects of harmonics in your electrical system?Harmonics are very harmful within an electrical system and can have serious consequences. For example, the presence of harmonics reduces the life of equipment. It is possible that the investment that you made in your motors & drives will not be realized if they are damaged and need replacing before their expected life span. This can be very expensive.Harmonics cause things to run hot, which cause stress on the cables and equipment. In the long term, this degrades an electrical system. The presence of harmonics will also mean that although you will get billed for the power that you are supplied, a large percentage of that power may be unusable. Harmonic mitigation is taking action to minimize the presence of harmonics in your electrical system and can achieve great cost savings.

WHAT IS HARMONIC MITIGATION?

Different types of Harmonic Mitigation devices at input (line) side of VSD (VFD)Line ReactorsAlso known as Inductors, Chokes & Line Filters.For use on the input of a VSD / Inverter or other non-linear devices.Virtually eliminate nuisance tripping.Extend life of semiconductors.Reduce harmonic distortion.Reduce surge currents.Improve true power factor.Passive Harmonic FiltersAlso known as 'Low Pass Filters'.For reducing harmonics at the VSD / Inverter or other non-

linear devices.Reduction of harmonics to 5-6%Reduce cable heating and line losses.Improve power factor and reduce system loss.Minimize interference with other equipment.Improved system voltage/current waveform.Prevent nuisance tripping of fuse and circuit breakers.Meets the IEEE519 Standard.Active Harmonic FiltersMainly used for group harmonic compensation at the main switchboard.Reduction of harmonics to 5% or less.Reactive current control.Load side transient suppression.Load side surge suppression. Reduction of supply sags and surges.Improves electrical system efficiency.Reduces operations and maintenance costs.Meets the IEEE519 Standard.

Output (load) side of VSD (VFD) Load ReactorsAlso known as Motor Chokes, Load Filters & Inductors.For use on the output of a VSD / Inverter or other non-linear devices.Protect motors from long lead effects.Reduce reflective currents.Reduce harmonic distortion.Reduce surge currents.Reduce motor temperature.Reduce motor audible noise.dV/dt FiltersdV/dt filters are designed to protect AC motors from the destructive effects of long lead peak voltages.Increase bearing life and up-time.Reduce common mode noise and currents.Prevent voltage spikes from exceeding 1 kV.Reduction in motor peak voltages.Protection of motor insulation.Reduction of motor temperature.Sine Wave FiltersIn addition to protecting the motor, the sine-wave filter also provides protection for the VSD / Inverter.Unshielded motor cables can be used, lower project costs.Motor operating life is increased.Longer motor cables possible.Significantly lower eddy current and stray flux losses.Significant reduction of bearing currents.Eliminate torque ripple.Eliminate voltage wave reflection.Reduces motor noise, vibration and heat.

Page 4: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

DOC. NO. CS-282TITLE: ENERGY SAVING IN COOLER FAN

Payback Period Approximately 4-5 Months

Industry : PaperApplication : Back Water PumpMotor rating : AC Induction Motor, 3-Phase 18.5 kW : 415 Volt : 1440 RPM : 50Hz : 35Amp :Previous system : Motor was running on Star Delta Starter.Problem observed : 1) High maintenance cost. 2) Energy losses due to flow control by valve.Present system : AXPERT-VT240S, 22 kW Variable Frequency Drive used. kW (Consumption) Valve PositionPrevious system (Without drive) : 18 kW 86 % OpenPresent system (With drive) : 13 kW 100 % OpenSystem block diagram :

Merits of new system : 1. Easy & smooth operation. 2. Energy saving due to flow control by VFD.Economical analysis :

Energy consumption without VFD - P1 = 18 kWEnergy consumption with VFD - P2 = 13 kWEnergy saving per day ((P1 - P2) x 24) = 120 UnitsSaving per day @ Rs. 5/- Unit = Rs. 600/-Saving per year (Approx. 320 Days) = Rs. 1,92,000/-

18.5 kW, 35 A, 3-PHASE INDUCTION MOTORAXPERT-VT240S

3-PHASE, 415 V,AC SUPPLY

22 kWBACK WATER PUMP

Page 5: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

AMTECH POWER CUSTOMER’S VOICE

Page 6: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

6

PRODUCT OVERVIEW

SUBSTATION AUTOMATIONSubstations are the building blocks for any grid. Amtech has been automating those substations ensuring highest interoperability, thanks to international standards like IEC 61850, and providing grid operators and owners with highest efficiency and increased productivity. Without adequate protection those substations can quickly come tumbling down.Amtech Grid Automation enables the digitalization of the grid so that our customers can improve reliability and ensure safe and clean energy supply to their consumers. Amtech’s substation automation systems offer a seamless and scalable solution for automating and providing visibility to power system networks.

Amtech’s intelligent Substation Automation System is used to manage the collected data for the purpose of system monitoring, evaluation, control, protection, and automation. Updating substation automation offers the opportunity to reduce operational and maintenance costs, increasing plant productivity with the aid of enhanced schemes as well as condition monitoring for circuit breakers, power transformers, etc. Led by our team of industry experts, Amtech can develop, integrate and deliver a complete automation system that is tailored to your specific needs and requirements. Solutions we are able to provide can be as straightforward as developing a local substation HMI to creating a complex solution that is integrated with SCADA or DCS systems and able to provide Fault diagnostic capability, Asset predictive diagnostics, Load shedding, and Secure engineering access.

Substation Automation System Key FeaturesFlexible AutomationProgrammable Logic EditorOnline ControlPredictive maintenance through analysis of

operating conditionsSophisticated built-in control & protection

algorithmsEnables integration of protection systemsProvides remote data retrieval & setting

capabilityCommon databaseWeb-enabled designIEC 61850 Substation AutomationSubstation Control & Monitoring System ApplicationsAutomatic voltage controlSynchronismTap position monitoringLoad & bus transferLoad curtailmentCapacitor control algorithmSubstation maintenance modeFault detectionSequence of event recorder

Page 7: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

CUSTOMER’S VOICE

Page 8: From the Desk of Managing Director · H.O. and Service Center Contact Person Phone No. (O) Mobile No. E-mail H.O. Gandhinagar Bhavana Thakkar 079-23289101-102-103 09909975944 sales@amtechelectronics.com

Gandhinagar

Atlanta

GandhinagarAhmedabad

Mumbai

Surat

MuzaffarnagarDelhi(Gurgaon)

VadodaraIndore

Jamnagar

Udaipur

Kolkata

Nagpur

Pune

Hyderabad

Vapi Raipur

Bhopal

Jamshedpur

JaipurLucknow

Vizag

Bangalore

Chennai

Belgaum

PondicherryTrichy

AurangabadNasik

Chandigarh

Veraval

M. D. Kamath

Paresh Patel

Regional Offices

Contact Person Phone No. (O) Mobile No. E-mail022-28846083Vrajesh Yadav 09819900501

09108051977

09825042458

[email protected]@amtechelectronics.com

[email protected]

MumbaiBangaloreChennaiDelhi

T. S. Sridhar 09840618533 09940229955.

[email protected]

Umesh Bhatia 09589344318Indore / Raipur [email protected]

H.O. and Service CenterContact Person Phone No. (O) Mobile No. E-mailBhavana Thakkar 09909975944H.O. Gandhinagar [email protected] Moradiya 09909973780Amtech Service Center

[email protected]

G. Sateesh Kumar 09573900222Hyderabad [email protected] C. 09932820680Kolkata [email protected]

09825042458095893443180957390022209932820680

09108051977

Pankaj Gulati 09888748620Chandigarh [email protected]