fs30 ice cooling

11
FS30 Ice Cooling FS30 Ice Cooling

Upload: vernon-fletcher

Post on 01-Jan-2016

36 views

Category:

Documents


1 download

DESCRIPTION

FS30 Ice Cooling. COLD PLATE AND ICE BIN. Out. Ice Bin. In. Cold Plate. COLD PLATE. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: FS30 Ice Cooling

FS30 Ice CoolingFS30 Ice Cooling

Page 2: FS30 Ice Cooling

COLD PLATE AND ICE BIN

In

Out

Cold Plate

Ice Bin

Page 3: FS30 Ice Cooling

COLD PLATE

Out

CARBONATOR PROBE FITING

SYRUP INLETS

WATER INLET

FOR PLAIN

WATER DRINKS

OUTLETS FOR CARBONATED WATER

OUTLETS FOR PLAIN WATER

WATER INLET TO

CARBONATOR PUMP

10º Pitch front to

back

The Cold Plate is located on the floor of the Ice Bin. The ice that lays on top is used for dispensing, but it also acts as the cooling agent to chill the water, brand syrups and soda water prior to dispensing.

Page 4: FS30 Ice Cooling

COLD PLATE THEORY

Heat is removed from water, soda and brand syrups during circulation through the cold plate.

In OutSyrup and water circuits

Page 5: FS30 Ice Cooling

COLD PLATE COOLING

Cold Plate Liquid enters warm

Liquid exits cold

Page 6: FS30 Ice Cooling

CARBONATED WATER OUTLETS

PRE-CHILL CIRCUIT

POST-CHILL CIRCUIT

ORIFICE (HIDDEN FROM

VIEW)

CARBONATOR TANK“PICTURE FRAME” OF 2” DIAMETER TUBING AROUND TUBING BUNDLES

OUTLETS OUT OF CARBONATOR

TANK, TO POST-CHILL CIRCUIT

COLD PLATE CIRCUITS

Water Level

Page 7: FS30 Ice Cooling

ICE BRIDGING

Ice Bridging

In Out

As the ice that is cooling the water and syrups melts, there is a tendency to create a hollow cavity in the ice just above the cold plate. This condition is referred to as “Ice Bridging”. The efficiency of the cooling is greatly reduced for the ice is no longer in contact with the cold plate.

Page 8: FS30 Ice Cooling

An agitator bar inside the ice bin rotates to break up the Ice Bridging and assures that the cold plate is covered with ice.

ICE BRIDGING

Page 9: FS30 Ice Cooling

ICE AGITATIONAgitator bars break up the bridging each time the wheel carries ice up to ice chute for dispensing.

Plus there is also periodic agitation when ice the dispensing is idle.

Periodic agitation times are:2 sec every 90 min’s - Cubed4 sec every 150 min’s - Pellett

Page 10: FS30 Ice Cooling

10

CONTROLLING THE ICE LEVEL

Ice Machine

Ice Adapter Plate

Maximum Ice Level below top of unit:

6” for cubed

9” for Cubelet

6 to 9”

Install bin thermostat between ice maker and dispenser to control ice level

Cubelet bin thermostat capillary tube holder

Cube bin thermostat capillary tube holder (P/N 82-3939)

Controlling the ice level within the bin is important to the cooling process . Too low a level could cause run outs, too much can effect the efficiency of the agitation.