KV 1/2" solenoid valves are designed for small hydraulic lifts operating at speeds up to 0.16 m/s (32 fpm) or 1 m/s (200 fpm)depending on the valve selected. The smooth and accurate ride characteristics of the KVH valve which includes 'soft stop' inboth directions, render it highly suitable for quality home lifts and lifts for the handicapped.
Flow Range: 5-80 l/min. (1.3-20 gpm) - see flow pressure charts on page 6 Pressure Range: 3-100 bar (45-1500 psi).Oil Viscosity: 25-60 mm²/sec. at 40°C (15-35 cSt. at 120°F) Max. Oil Temperature: 70°C (158°F)Solenoids AC: 24 V/1.8 A, 42 V/1.0 A, 110 V/0.5 A, 230 V/0.18 A, 50/60 Hz Insulation Class, AC and DC: IP 68Solenoids DC: 12 V/2.1 A, 24 V/1.1 A, 42 V/0.6 A, 80 V/0.3 A, 110 V/0.25 A, 196 V/0.14 A.Ports: P Pump, Z Cylinder and T Tank all G1/2"
Control Valves for Small Lifts
Speeds max. (EN code)
Up One up speed, 0.16 m/s (32 fpm) max.Up start has built-in damping.Up stop has no damping (pump stops).
Down One down speed, 0.16 m/s (32 fpm) max.Down start has adjustable damping.Down speed is adjustable.Down stop has built-in damping.
Up One up speed 0.16 m/s (32 fpm) max. with soft stop,or 0.4 m/s (80 fpm) max. with overtravel and releveling.Up start has built-in damping.Up stop has adjustable damping (delayed pump stop required).
Down One down speed, 0.16 (32 fpm) max.Down start has adjustable damping.Down speed is adjustable.Down stop has built-in damping.
Up One up speed, 0.16 m/s (32 fpm) max.Up start has built-in damping.Up stop has no damping (pump stops).
Down Two down speeds, 1 m/s (200 fpm) max.Down start has adjustable damping.Fast down speed and leveling speeds are adjustable.Slow down and stop have built-in damping.
Up One up speed, 0,16 m/s (32 fpm) max. with soft stop,or 0.4 m/s (80 fpm) max. with overtravel and releveling.Up start has built-in damping.Up stop has adjustable damping (delayed pump stop required).
Down Two down speeds, 1 m/s (200 fpm) max.Down start has adjustable damping.Fast down speed and leveling speeds are adjustable.Slow down and stop have built-in damping.
Up Two up speeds, 1 m/s (200 fpm) max.Up start has built-in damping.Up stop has adjustable damping (delayed pump stop required).
Down Two down speeds, 1 m/s (200 ft/m) max.Down start has adjustable damping.Fast down speed and leveling speeds are adjustable.Slow down and stop have built-in damping.
![Page 2: Full Kv Valves Info](https://reader035.vdocument.in/reader035/viewer/2022081809/54f7fd424a79591c638b4fea/html5/thumbnails/2.jpg)
7
7
1
6
7
5
1
9
6
1
9
1
9
6
1
KV1S
9
9
6
5 6
5
5
D
D
9
D6
S 1
AD6
1S
9
7 9 S 1
C6 D
5
AC6 D
7 9 S 1
7 9 S 1 3
ACD6
KV1P
KV2P
KV2S
KVH
4
5
1
U
A
KS9 7
Y X
6
S
4
HPDHDL
BV
RSES
M
1
U
6
HPDHDL
BV
RSES
M
3
A
5
KS
F
H
D C
EN
S
V
XY
79
CDEN
F
H
1
U
6
HPDHDL
BV
RSES
M
KS
F
H
D C
EN
S
V
XY
79
1
U
6
HPDHDL
BV
RSES
M
A
5
KS
F
H
D
EN
S
V
Y
9
1
U
6
HPDHDL
BV
RSES
M
KS
F
H
D
EN
S
V
Y
9
CA
DC
A
DC
DC
A
V
3
34
B44
BLAIN HYDRAULICS 2
EN ISO 9001
2
ElectricalSequence
For Options:BV, EN, HP,KS,DH andDLsee page 4.
Hydraulic Circuit
Mot
or
Alternative Overtravel
Mot
orM
otor
Mot
or
Alternative Overtravel
Mot
or
Control Elements
A Solenoid (Up Stop)C Solenoid (Up Deceleration) &
Solenoid (Down Deceleration)D Solenoid (Down Stop)U Bypass ValveH Manual Lowering
Adjustments DOWN
6 Down Acceleration7 Down Full Speed9 Down Leveling SpeedDown Deceleration built-in
Adjustments UP
1 Bypass3 Up Decelaration &
Soft Stop4 Up Leveling Speed5 Up Soft StopUp Acceleration built-in
V Check ValveX Down ValveY Down Level ValveF Main FilterS Relief Valve
![Page 3: Full Kv Valves Info](https://reader035.vdocument.in/reader035/viewer/2022081809/54f7fd424a79591c638b4fea/html5/thumbnails/3.jpg)
KV1P
KV1S
KV2P
KV2S
KVH
3BLAIN HYDRAULICS
Adjustments UP
1. Up Bypass: When the pump is started, the unloaded car should remain stationary at the floor for a period of about 1 secondbefore starting upwards. The length of this delay is according to the setting of adjustment 1.'In' (clockwise) shortens the delay,'out' (c-clockwise) lengthens the delay.
Up Stop: At floor level, the pump-motor is de-energized. The stop may be abrupt depending on load and speed of approach. Noadjustment possible.
S Relief Valve: 'In' (clockwise) produces a higher, 'out' (c-clockwise) a lower maximum pressure setting (3 mm Allan Key).
1. Up Bypass: When the pump is started, the unloaded car should remain stationary at the floor for a period of about 1 secondbefore starting upwards. The length of this delay is according to the setting of adjustment 1.'In' (clockwise) shortens the delay,'out' (c-clockwise) lengthens the delay.
5. Up Stop: At floor level solenoid A is de-energized. Through a time relay the pump must run approx. 1/2 seconds longer to allowthe car to stop smoothly by valve operation according to the setting of adjustment 5. 'In' (clockwise) provides a softer stop, 'out'(c-clockwise) a quicker stop. Pre-adjustment: With solenoid A disconnected and the pump running, 5 should be turned in until thecar starts to move up, then slowly backed off again until the car stops.
Alternative Up Stop: At relatively higher speeds and with the time relay arrangements as with 'up stop' above, the car maytravel to just above floor level. In overtravelling the floor, down leveling solenoid D is energized, lowering the car smoothly backdown to floor level where D is de-energized.
S Relief Valve: 'In' (clockwise) produces a higher, 'out' (c-clockwise) a lower maximum pressure setting (3 mm Allan Key).
1. Up Bypass: When the pump is started, the unloaded car should remain stationary at the floor for a period of about 1 secondbefore starting upwards. The length of this delay is according to the setting of adjustment 1.'In' (clockwise) shortens the delay,'out' (c-clockwise) lengthens the delay.
Up Stop: At floor level, the pump-motor is de-energized. The stop may be abrupt depending on load and speed of approach. Noadjustment possible.
S Relief Valve: 'In' (clockwise) produces a higher, 'out' (c-clockwise) a lower maximum pressure setting (3 mm Allan Key).
1. Up Bypass: When the pump is started, the unloaded car should remain stationary at the floor for a period of about 1 secondbefore starting upwards. The length of this delay is according to the setting of adjustment 1.'In' (clockwise) shortens the delay,'out' (c-clockwise) lengthens the delay.
5. Up Stop: At floor level solenoid A is de-energized. Through a time relay the pump must run approx. 1/2 seconds longer to allowthe car to stop smoothly by valve operation according to the setting of adjustment 5. 'In'' (clockwise) provides a softer stop, 'out'(c-clockwise) a quicker stop. Pre-adjustment: With solenoid A disconnected and the pump running, 5 should be turned in until thecar starts to move up, then slowly backed off again until the car stops.
Alternative Up Stop: At relatively higher speeds and with the time relay arrangements as with 'up stop' above, the car maytravel to just above floor level. In overtravelling the floor, down leveling solenoid D is energized, lowering the car smoothly backdown to floor level where D is de-energized.
S Relief Valve: 'In' (clockwise) produces a higher, 'out' (c-clockwise) a lower maximum pressure setting (3 mm Allan Key).
1. Up Bypass: When the pump is started, the unloaded car should remain stationary at the floor for a period of about 1 secondbefore starting upwards. The length of this delay is according to the setting of adjustment 1.'In' (clockwise) shortens the delay,'out' (c-clockwise) lengthens the delay.
3. Deceleration: When C is de-energized, the car decelerates according to adjustment 3 to leveling speed. 'In' (clockwise) providesa softer, 'out' (c-clockwise) a rougher deceleration.
4. Up Leveling: With solenoid C de-energized (see 3) the car will proceed at its leveling speed according to the setting of adjustment4. 'In' (clockwise) provides a quicker, 'out' (c-clockwise) a slower leveling speed.
3. Up Stop: At floor level solenoid A is de-energized. Through a time relay the pump must run approx. 1/2 seconds longer to allowthe car to stop smoothly by valve operation according to the setting of adjustment 3. 'In' (clockwise) provides a softer stop, 'out'(c-clockwise) a quicker stop. Pre-adjustment: With solenoid A disconnected and the pump running, 3 should be turned in until thecar starts to move up, then slowly backed off again until the car stops.
S Relief Valve: 'In' (clockwise) produces a higher, 'out' (c-clockwise) a lower maximum pressure setting (3 mm Allan Key).
Nominal Settings: Adjustment 1 (and 4 at KVH) level with flange faces. Adjustment 3 (at KVH) all the way 'in' (clockwise) then threeturns 'out' (c-clockwise). Adjustment 5 (KV1 & KV2) level with flange faces.
Valves are already tested and adjusted. Check electrical operation before changing valve settings. Test that the correct solenoid isenergized by removing nut and raising solenoid slightly to feel pull.
![Page 4: Full Kv Valves Info](https://reader035.vdocument.in/reader035/viewer/2022081809/54f7fd424a79591c638b4fea/html5/thumbnails/4.jpg)
BV HP EN
90
60
30
44
90°
65
65
DH/DL KS
4
DH/DL KS
BV HP EN
BLAIN HYDRAULICS
Options are shown with KV1P Valve. The same Optionscan be applied to all other KV Valve types .
KV Example with Options
KV Optional Equipment
BV Ball Valve built inEN Emergency Power SolenoidHP Hand PumpKS Slack Rope ValveDH Pressure SwitchDH Pressure SwitchUL UL/CSA Solenoids
KV1P / KV1S6. Down Acceleration: When solenoid D is energized, the car will accelerate downwards according to the setting of adjustment 6.
'In' (clockwise) provides a softer down acceleration, 'out' (c-clockwise) a quicker acceleration. Pre-adjustment: 6 should be turnedall the way in and then solenoid D energized. Turn 6 slowly back out until the car accelerates downwards.
7. Down Speed: With solenoid D energized as above, the down speed of the car is according to the setting of adjustment 9. 'In'(clockwise) provides a slower down speed, 'out' (c-clockwise) a faster down speed.
Down Stop: At floor level, solenoid D is de-energized causing the car to stop. No adjustment necessary.H Manual Lowering: 'out' (c-clockwise) allows the car to be lowered by hand. Closes automatically on release.
KV2P / KV2S / KVH6. Down Acceleration: When solenoids C and D are energized, the car will accelerate downwards according to the setting of
adjustment 6. 'In' (clockwise) provides a softer down acceleration, 'out' (c-clockwise) a quicker acceleration. Pre-adjustment: 6should be turned all the way in and then solenoid C and D energized. Turn 6 slowly back out until the car accelerates downwards.
7. Down Speed: With solenoids C and D energized as above, the down speed of the car is according to the setting of adjustment7. 'In' (clockwise) provides a slower down speed, 'out' (c-clockwise) a faster down speed.
Down deceleration: When solenoid C is de-energized whilst solenoid D remains energized, the car will decelerate according to thebuilt-in damping. No further adjustment will be required.
9. Down Leveling: With solenoid C de-energized and solenoid D remaining energized, the car will travel at its down leveling speedaccording to the setting of adjustment 9. 'In' (clockwise) provides a slower, 'out' (c-clockwise) a faster down leveling speed.
Down Stop: At floor level, solenoid D is de-energized causing the car to stop. No adjustment necessary.H Manual Lowering: 'out' (c-clockwise) allows the car to be lowered by hand. Closes automatically on release.
KS Slack Rope Valve Nominal Settings: With the end of adjustment K initially level with flange faces, open the manual lowering.Thecar without load should descend. Turn 'in' (clockwise) adjustment K until the car comes to a stop then 'out' (c-clockwise) againuntil it again descends. In case the car does not come to a stop, i.e. at pressures over 15 bar, turn 'in' (clockwise) K all the way andthen back 'out' (c-clockwise) half a turn. See also KS sheet.
Valves are already tested and adjusted. Check electrical operation before changing valves settings. Test that the correct solenoidis energized by removing nut and raising solenoid slightly to feel pull.
KV Nominal Settings: Adjustments 7 & 9, screwheads level with the hexagon heads.
Adjustments DOWN
Optional
Separate Equipment
RS Pipe Rupture ValveES Pipe Rupture Valve End Switch
![Page 5: Full Kv Valves Info](https://reader035.vdocument.in/reader035/viewer/2022081809/54f7fd424a79591c638b4fea/html5/thumbnails/5.jpg)
34,5
M6
PT
65
8
P
M6
M6
25
3614
T
50
BLAIN HYDRAULICS
KV1P KV1S
65
110
7 44
37
50
4015,5
111
20
5
KS
6
1
9
5
L SHKS
T Y U P
KV1P KV1S
AD6KV2P KV2S
ACD6
L KS H 7 9 S
VF VF Y
T P U
T P
4
3
L H 7 9 S
7
M6
19
Z
7,5
Z
M6
T P
11012
5
P
M6
20
34
2565
15,5 10,5
KV2P
T
50
110
100
4030 34,5
50
65
KV2S, KVH
Z
Z
34
1
5
1
C ADKVH
125
Z
Z
Z
Z
X
Measurements
Assembly
Adjustments
1 Bypass3 Deceleration &
Soft Stop 'Up'4 Leveling 'Up'5 Soft Stop 'Up'6 Start 'Down'7 Speed 'Down'9 Leveling 'Down'S Relief Valve
Connections
P PumpT TankZ Cylinder
KV1P andKV1S
KV2P andKV2S
Control Elements
A Solenoid 'Up Stop'C Solenoid 'Up Deceleration' &
Solenoid 'Down Deceleration'D Solenoid 'Down Stop'U Bypass ValveV Check ValveX Down ValveY Down Leveling ValveH Manual LoweringL Gauge Shut Off CockF Main Filter
![Page 6: Full Kv Valves Info](https://reader035.vdocument.in/reader035/viewer/2022081809/54f7fd424a79591c638b4fea/html5/thumbnails/6.jpg)
4
Z
7+9
10 20 30 40 50 60 70 80 90 100 110 120 130140 150
100
90
80
70
60
50
40
30
20
10
1400
1200
1000
800
600
400
200
5 10 15 20 25 30 35
S
3+5
US gpm
l/min
US gpm
5 10 15 20 25
10 20 30 40 50 60 70 80 90 100l/min
5 10 15 20 25
10 20 30 40 50 60 70 80 90 100
US gpm
l/min
300200100
400300200100
20
10
30
20
10
↓
KV1&KV2
1
S
KV
H
KS
MM
M
DR6
MO
6
DF
N6
DK
DG
S6 AS
AH
AF
AN
MO
AR
M
AD
20
KV1
KV2
10 40
80
KVH, KV1S, KV2S
KVH
Z
DH/DL
L KS H S L KS H 7
D/6D/6C
KV1SKV2SKVH
ZA VFFF F EO
FZA V VO
7ESM9F76
X / Y8
MSSZ SOYOFIXTXO
1F1EUF UOU EO
6 7 8HO
SESMMSSOSZSFSK
MM
6 May 98 BLAIN HYDRAULICS Designers and Builders of High Quality Valves for Hydraulic Elevators Printed in Germany
bar psi bar
bar psi
psi
KV1P, KV1S,KV2P, KV2S
↓
↓KVH
BOWWOVO WB 4E
D
DR
MO
DF
DNHN
DK
HS DG
S6
M
MM
C A
4 KVH
A
0-Ring: 13x1 V0-Ring: 5,28x1,78 - V
0-Ring: 9x2 P
A
0-Ring: 5,28x1,78 - V
0-Ring: 21x2 P
CO
KV2KVH
KV2KVH
1 3 KVH
5 KV2S
KVH
KV1P KV1S
KV2SKVHKV2P
9 0-Ring: 9x2 P
5
91
Z
DH/DL
For pressure-flow conditions withinshaded area, use 3/4" piping toavoid unnecessary power loss.Pump flows above 80 l/min. notrecommended
Example orderKV2S, 65 l/min, 25 bar (empty),220WSor: KV2S/80/220WS
Pressure Drop P - ZInsert Selection and Down Flow Chart
Solenoid Valves AdjustmentsPos. No. Item1 1F Flange - Bypass
1E Adjustment - BypassEO 0-Ring - Adjustment (3,5x1,5 - P)U Flow Guide - BypassUO 0-Ring - Bypass (17x1 - V)UF Spring - Bypass
3 3 Adjustment Up Deceleration4 4E Adjustment Up Levelling
WB Sleave - Check ValveBO 0-Ring - Sleave (11x1 - V)W Up Levelling ValveWO 0-Ring - Up Levelling Valve (5x1 - V)VF Spring - Check ValveFF Guide - Check Valve
5 5 Adjustment - Up Stop6 6 Adjustment - Down Acceleration
7+9 7E Adjustment - Down Valve9F Spring - Down ValveYO 0-Ring - Flow Guide (10x1 - V)XO Seal - Flow Guide (5.28x1.78 - P)XT 0-Ring DiscX Down Flow Guide (Brass)Y Down Levelling Flow Guide (Steel) - KV2Y Down Flow Guide (Steel) - KV1
S SE Adjustment Screw - Relief ValveSM Hexagonal - Relief ValveMS Locking ScrewSO 0-Ring - NippleSZ Nipple - Relief ValveSF Spring - Relief ValveSK Piston - Relief Valve
H H Manual Lowering - Self ClosingHO Seal - Man. Lowering (0-Ring 5.28x1.78 - V)
KS KS Slack Rope ValveA+B MM Nut Solenoid
AD Collar SolenoidM Coil Solenoid (indicate voltage)AR Tube Solenoid 'Up'MO 0-Ring SolenoidAN Needle Solenoid 'Up'AF Spring Solenoid 'Up'AH Seat Housing 'Up'AS Seat Solenoid 'Up'
C+D M Coil Solenoid (indicate voltage)C DR Tube - Solenoid 'Down', w/o adj. 6D DR6 Tube Solenoid 'Down', with adj. 6
MO 0-Ring SolenoidDF Spring Solenoid 'Down'
C DN Needle Solenoid 'Down'D N6 Needle Solenoid 'Down' (Nipple)C HN Needle Solenoid 'Down'
DK Core Solenoid 'Down'DG Seat Housing 'Down'(Solen.D with screen)
C S6 Seat Solenoid 'Down'C HS Seat Housing 'Down'C CO 0-Ring Seat HousingZ ZA Cylinder Thread Connection
V Check ValveVO 0-Ring Check Valve (5,28x1,78 - V)F Main Filter
L L Gauge Shut Off Cock
Parts List
Flow Valves
Sta
tic p
ress
ure
with
em
pty
car.
Lowest Relief Pressure
0-Rings: V - VitonP - Perpunan
In case of down leakage, replace and testin the following order:KV1P, KV1S, KV2P, KV2S: S6, N6, HO,YO (and XO with KV2), V complete.KVH: S6, N6, HN, HS, CO, HO, YO, XO,W complete.