full service - electric fire pump controllers · pdf file• run test push button •...
TRANSCRIPT
1GPxGPx
GPx SeriesFull Service - Electric Fire Pump Controllers
2016-2017OPTIONAL
Standard Features• ViZiTouch V2 operator interface• NEMA 2 assembly• Pressure and event recorder• Voltage and amperage display• Single operator for both isolating switch and circuit breaker• Surge arrestor• Lifting lugs• Run test push button• Available with automatic power transfer switch• Emergency start handle
• Start and stop pushbuttons• Locked rotor protector• Phase reversal indication• Remote start / deluge valve start provision• Pressure transducer and run test solenoid valve externally mounted• Gland plate• Audible alarm• Alarm contacts for remote indication• Available with full voltage and reduced voltage starting
2GPx
GPx SeriesGPx
GPA model shown
Alarm bell
Externally mounted pressuretransducer and run test solenoidvalve with protective cover
Lifting Lugs
ViZiTouch V2 operator interface
Exterior USB Port (Interior USB port also supplied)
Custom designed Isolation switch / Circuit breaker operator handle
Key lock
Remote alarm contacts withremovable terminals
Surge arrestor
Custom designed emergency startmechanism with integrated limit switch
Gland plate
Automatic power transfer switch
GPW + GPU model shown
1
2
4
6
5
7
1
5
9
2
6
10
3
7
4
8
3
11
12
8
9
10
1112
3GPx
GPx Series
ViZiTouch V2 major features include:• Touch screen operation with 7” color display and intuitive graphics• Multi-language• Upgradable software• Password protected
ConfigHome 26C14:34:282016.Dec.01
Pressure
Periodic test
Advanced
PSI
PT1
Duration (min)
14:09:552016.Dec.01
Cut-in
Cut-out 150
100
Monday
Week. Test
Auto. Shutdown (m)
Date and time
RUN TEST
User login
Duration (min) 10
Duration (min) 10
30
5
7
Max. Pres. 300
2
EventsHistory 26°C14:34:282016.Dec.01
2016.12.01
2016.12.01 Under Voltage: ACTIVE
Under Voltage INACTIVE
2016.12.01 Alarms Reset
2016.12.01
2016.12.01
2016.12.01
2016.12.01
2016.12.01
2016.12.01
2016.12.01
14:28:23
14:28:52
14:28:09
14:09:55
14:11:22
14:03:11
14:08:46
14:03:03
14:12:06
14:28:08 ACB in OFF or Tripped: INACTIVE
Alternate is Tripped/Open: INACTIVE
Control Voltage not Healthy: ACTIVE
Generator: Started
Motor: Started in Automatic
Loss of Power: ACTIVE
Pump On Demand: INACTIVE
ServiceHome 26C14:33:062016.Dec.01
Last service date
Commissionning date
Service interval
Nameplate Information
Jockey pump cut-in
Live view
Jockey pump cut-out
Complete service
Next service due
2016.12.01 14:28:52
2016.12.01 14:28:52
1 year
130
2016.12.01 14:28:52
110
+ 65 6795 8114+ 65 6795 7823
ASIA
+ 32 (0) 1084 4001EUROPE
+ 1 800 363 8448+ 514 334 0523
AMERICAS
+ 971 (0)4 887 0615MIDDLE EAST
Pressure CurvesHistory 26°C14:37:172016.Dec.01
150
120
90
60
30
0
2016.02.2314:24:05
2016.02.2314:25:05
1m 5m 20m 1h 2h 3h 4h 5h 6h 12h 1d 2d 3d 4d 5d 6d 1w 2w
StatisticsFirst Service StatisticsStatistics 26C14:34:282016.Dec.01
First Service Statistics
From
2016.12.01Since
2016.12.01
14:28:09
20
0-00-08-57
14:08:46
99.1 PSI
61-04-08-27On Time
Motor
Start Count
Last Started On
Pressure
Minimum
On Time
Home Screen
Electric Fire Pump Controller
Settings History/Statistics
EventsService
Pump Curves Pressure Curves
PMS 295 PMS 361 Noir
®
ViZiTouch V2 operator interface
GPx
GPxHome 53C06:45:342016.Dec.01
Non pressure actuated Automatic controller Automatic shutdown
N2
N3
N1
A2
A3
A1
480 V 480 V
480 V
0 V0 V
0 V
480 V 480 V
480 V
23.4A
23.4A
23.4A
MANUAL
0
300
System
70PSI
90110
0
300
System
Home 26C13:34:102016.Dec.01
Pressure actuated Non automatic controller Automatic shutdown
L2
L3
L1480 V 480 V
480 V
23.4A
23.4A
23.4A
90
150
70PSI
Electric Fire Pump Controllerwith Automatic Transfer Switch
0
300
System
Home 26C13:34:102016.Dec.01
Pressure actuated Non automatic controller Automatic shutdown
L2
L3
L1480 V 480 V
480 V
23.4A
23.4A
23.4A
90
150
70PSI
On-screen menuHome
Alarm
Configuration
History
Service
Manual
Languages
Pump CurvesHistory 26°C14:37:172016.Dec.01
P
90
68
45
23
01075538 1613 2150 Q 2016.02.23
14:25:05
4GPx
LISTEN • DEVELOP • LEADwww.tornatech.com
Tornatech Inc. Head Office - Montreal, Quebec, Canada Tel.: + 1 514 334 0523 Toll free: + 1 800 363 8448 Fax: + 1 514 334 5448
Tornatech Europe SPRL - Wavre, Belgium Tel.: + 32 (0) 10 84 40 01 Fax: + 32 (0) 10 24 75 05
Tornatech FZE - Dubai , United Arab Emirates Tel.: + 971 (0)4 887 0615 Fax: + 971 (0)4 887 0604
Tornatech Pte Ltd. - Singapore Tel.: + 65 6795 8114 Tel.: + 65 6795 7823 Fax: + 65 6795 3201 AsiaMiddle EastEuropeAmericas
GPx-SBRO-003-E Rev.0 Printed in Canada
GPx
GPx SeriesACROSS-THE-LINE
PARTWINDING
AUTOTRANSFORMER
SOFT STARTSOFT STOP
PRIMARYRESISTOR
WYE-DELTACLOSED
TRANSITION
WYE-DELTAOPEN
TRANSITION
MODEL NUMBER GPA GPP GPR GPS GPV GPW GPYVOLTAGE FULL REDUCED REDUCED REDUCED REDUCED REDUCED REDUCED
TYPICAL VOLTAGE APPLIED MOTOR STARTING 100% 100% 65% 30% (adjustable) 70% 100% 100%
INRUSH CURRENT 6 X FULLLOAD CURRENT
60% OF FULL LOAD CURRENT WITH 1ST WINDING
42% OF FULL LOAD CURRENT
30% OF FULL LOAD CURRENT
(adjustable)
50% OF FULL LOAD CURRENT
33% OF FULL LOAD CURRENT
33% OF FULL LOAD CURRENT
STARTING TORQUE 100% 48% 42% 30% 50% 33% 33%
MOTOR TYPE STANDARD SPECIAL STANDARD STANDARD STANDARD SPECIAL SPECIAL
# OF WIRECONNECTIONS 3 WIRE 6 WIRE 3 WIRE 3 WIRE 3 WIRE 6 WIRE 6 WIRE
Model Voltage HP Short Circuit Withstand Rating
Seismic Certified
GPA GPA+GPU
GPP GPP+GPU
GPY GPY+GPU
200V - 208V5-150 100kA Yes
200 50kA No
220V - 240V5-200 100kA Yes
250 50kA No
380V - 416V5-300 100kA Yes
350-450 50kA No
440V - 480V
5-400100kA
Yes
450No
50050kA
575V - 600V 5-500 Yes
GPR GPR+GPU
GPW GPW+GPU
200V - 208V5-150 100kA Yes
200 50kA No
220V - 240V5-200 100kA Yes
250 50kA No
380V - 416V5-300 100kA Yes
350-450 50kA No
440V - 480V
5-400100kA
Yes
450No
50050kA
575V - 600V 5-500 Yes
Model Voltage HP Short Circuit Withstand Rating
Seismic Certified
GPS GPS+GPU
200V - 208V
5-100100kA
Yes
150No
200 50kA
220V - 240V
5-150100kA
Yes
200No
250 50kA
380V - 416V
5-250100kA
Yes
300No
350-450 50kA
440V - 480V
5-300
100kA
Yes
350
No400
450
500
50kA575V - 600V
5-400 Yes
450No
500
GPx Series / Voltage / HP / Short Circuit Withstand Rating / Seismic Certification
GPx Models / Starting Methods
Based on NEMA B type motors.
How to order: GPx - V / HP / Ph / Hz / options Ex.: GPA - 208 / 30 / 3 / 60 / options