GENERAL NOTES FLOOR PLANS WERE PROVIDED BY THE OWNER AND MAY NOT REFLECT REVISIONS MADE DURING CONSTRUCTION OR RENOVATION MADE AFTERWARDS. INFORMATION SHOWN PERTAINING TO EXISTING CONDITIONS IS BASED UPON VISUAL INSPECTION AND EXISTING CONSTRUCTION DOCUMENTS USED BY THE ARCHITECT. ANY DISCREPANCIES DISCOVERED BY OTHERS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BEGINNING WORK. 2. ALL INTERIOR DIMENSIONS ON PLAN SHEETS ARE.... A: FACE OF STUD TO FACE OF STUD, (EXCLUSIVE OF FINISH MAT'L) UNLESS OTHERWISE NOTED. B: FACE OF STUD TO FACE OF EXISTING WALL, UNLESS OTHERWISE NOTED. C: ALL INTERIOR STUDS TO BE SPACED @ 1' - 4" o.c. UNLESS OTHERWISE NOTED. 3. GC TO COORDINATE ADDITIONAL NOTES AND DIMENSIONS BETWEEN 1/8" SCALE AND ENLARGED PLANS. 4. SEE LIFE SAFETY PLANS FOR FIRE RATED PARTITIONS. 5. UNLESS OTHERWISE NOTED, OWNER TO PROVIDE INTERIOR ROOM SIGNAGE. CONTRACTOR TO COORDINATE INSTALLATION w/SIGN VENDOR. 6. SEE PLUMBING PLANS FOR FLOOR DRAIN LOCATIONS. PROVIDE POSITIVE DRAINAGE TO FLOOR DRAIN. COORDINATE WITH ALL TRADES. 7. IN THE EVENT OF ANY DISCREPANCIES AND / OR ERRORS FOUND IN THE DRAWINGS, OR IF PROBLEMS ARE ENCOUNTERED DURING DEMOLITION. THE CONTRACTOR SHALL BE REQ'D TO NOTIFY THE DESIGNER BEFORE PROCEEDING WITH THE WORK. IF THE DESIGNER IS NOT NOTIFIED, THE CONTRACTOR SHALL TAKE RESPONSIBILITY FOR THE COST OF ANY REVISION. 8. IN THE EVENT THAT THERE ARE QUESTIONS CONCERNING THE HANDLING OF ANY CONTAMINATED MATERIALS, THE CONTRACTOR SHALL COORDINATE SUCH ISSUES WITH THE OWNERS REPRESENTATIVE. ALL MATERIALS SHALL BE HANDLED FOR DISPOSAL PROPERLY IN ACCORDANCE WITH ALL APPLICABLE LAWS AND REGULATIONS AT APPROVED FACILITIES WHICH ARE LICENSED AND / OR APPROVED FOR THE DISPOSAL OF OR HANDLING OF SUCH MATERIALS. 9. THIS WORK CONSISTS OF CLEARING, REMOVING AND DISPOSING OF ALL BLDG. DEMOLITION DEBRIS AND UTILITIES NOT REMOVED BY OTHERS THAT ARE WITHIN DESIGNATED PROJECT AREAS EXCEPT FOR SUCH OBJECTS THAT THE DESIGNER DESIGNATES TO REMAIN. THE WORK SHALL ALSO INCLUDE PRESERVING AND PROTECTING FROM INJURY OR DEFACEMENT OF ALL VEGETATION, STRUCTURE & OBJECTS DESIGNATED TO REMAIN. 10. CONTRACTOR TO COORDINATE ALL UTILITY DEMOLITION AND REMOVAL WITH PROPER AGENCIES. 11. CONTRACTOR TO COORDINATE WITH THE RESPECTIVE UTILITIES TO HAVE ALL UTILITY SERVICES REMOVED OR DISCONNECTED PRIOR TO THE COMMENCEMENT OF ANY DISCONNECTED, CAPPED OFF, PLUGGED OR OTHERWISE SECURED UTILITIES. CARE SHALL BE EXERCISED SO AS NOT TO DAMAGE ANY MAIN UTILITY LINES DUE TO DEMOLITION ACTIVITIES AND ANY SUCH DAMAGES WILL BE REPAIRED TO THE REQUIREMENTS OF THE RESPECTIVE UTILITY AR THE CONTRACTORS EXPENSE. ASSURE PROPER FUNCTION OF REMAINING UTILITIES UPON COMPLETION & REWORK. 12. CONTRACTOR SHALL MAKE ALL NOTIFICATIONS AND OBTAIN ALL PERMITS ASSOCIATED WITH THE DEMOLITION / REMOVAL OF BUILDINGS AND ANY RELATED APPURTENANCES. 13. PRIOR TO DEMOLITION OF ANY EXISTING CONSTRUCTION / ELEMENTS / EQUIPMENT ON ANY TRACT OR LOT, CONTRACTOR SHALL INSURE THAT ANY AND ALL HAZARDOUS MATERIALS INCLUDING BUT NOT LIMITED TO FRIABLE ASBESTOS CONTAINING MATERIAL SHALL BE HANDLED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REQUIREMENTS. THIS INCLUDES ANY NOTIFICATIONS AND PERMITS REQ'D. 14. ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS (NESHAP) PROMULGATED BY THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (USEPA), AND THE OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). 15. CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL MEASURES NECESSARY TO INCLUDE SILT FENCES AND INLET PROTECTION WHERE WATER DRAINS OFF DISTURBED AREAS, SEDIMENT AND EROSION CONTROL MEASURES SHALL BE IN PLACE PRIOR TO DEMOLITION OR CONSTRUCTION ACTIVITIES. 16. CONTRACTOR SHALL NOT DISTURB EXISTING CONDITIONS OUTSIDE LIMITS OF WORK UNLESS OTHERWISE NOTED; ANY DAMAGES INCURRED WILL BE REPAIRED AT CONTRACTOR'S EXPENSE. 17. THE ABBREVIATION G.C. WHERE SHOWN ON THE DRAWINGS, SHALL MEAN GENERAL CONTRACTOR. 18. THE G.C. SHALL SEAL ALL OPENINGS AROUND PIPES, DUCTWORK, ETC. THAT PENETRATE PARTITIONS ABOVE THE FINISHED CEILING. ALL WORK AND SEALANT MATERIAL SHALL BE APPROVED BY ARCHITECT. 19. THE G.C. SHALL PROVIDE ALL REQUIRED FIRE EXTINGUISHERS. 20. ALL EXTERIOR WALLS AND INTERIOR PARTITIONS SHALL EXTEND TO UNDERSIDE OF ROOF OR FLOOR DECK UNLESS NOTED OTHERWISE. 21. VERIFY SIZE AND LOCATION OF ALL LOUVERS, OPENINGS, AND CONCRETE PADS REQUIRED BY THE HEATING CONTRACTOR. HEATING CONTRACTOR TO CONDUCT COORDINATION MEETINGS w/ ALL DISCIPLINES. 22. EQUIPMENT, CABINETRY AND FURNISHINGS SUPPLIERS SHALL FIELD VERIFY ALL DIMENSIONS FOR NEW ITEMS BEFORE FABRICATION AND INSTALLATION. SHOP DRAWING SHALL CONTAIN VERIFIED DIMENSIONS WHERE POSSIBLE. 23. G.C. TO INSTALL WOOD OR METAL BLOCKING AS REQUIRED FOR INSTALLATION OF CASEWORK. MILLWORK, GRAB BARS, AND ANY OTHER ITEMS THAT REQUIRE SECURE ATTACHMENT TO WALLS AND/OR CEILINGS. 24. CONTRACTORS SHALL NOTE THAT MATERIALS CONTAINING ASBESTOS MAY BE ENCOUNTERED WHEN WORKING IN THE EXISTING BUILDING. CONTRACTORS SHALL COORDINATE THEIR WORK WITH THE OWNER. ALL ASBESTOS RELATED WORK SHALL BE COMPLETED BY THE ASBESTOS ABATEMENT CONTRACTOR. 1. PERFORM WORK AS REQ'D FOR PROPER COMPLETION OF THE WORK. THE DRAWINGS MAY NOT SHOW ALL EXISTING ITEMS OR CONDITIONS. CONTRACTOR SHALL NOT REC'V EXTRA PAYMENT FOR REQUIREMENTS WHICH CAN BE INFERRED THROUGH OBSERVATION OF EXISTING CONDITIONS AT THE SITE. IN THE EVENT CONCEALED CONDITIONS ARE ENCOUNTERED, WHICH MAY VARY SIGNIFICANTLY FROM THOSE INDICATED ON THE DRAWINGS, NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. ENLARGED PLANS SHALL HAVE PRECEDENCE OVER SMALL-SCALE PLANS. CONTRACTOR SHALL FIELD VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE. WHERE WORK IS PERFORMED IN EXISTING AREAS, THE EXISTING FINISHED CONDITIONS ARE TO BE REPAIRED OR REPLACED. THESE FINISHED CONDITIONS ARE TO MATCH EXISTING UNLESS OTHERWISE NOTED. WHERE NEW FINISHED CONDITIONS ARE TO BE INSTALLED, EXISTING FINISHED CONDITIONS ARE TO BE REMOVED BY THE CONTRACTOR AND APPROPRIATE PREPARATION OF SUBSTRATE SHALL BE COMPLETED FOR SPECIFIED FINISH. ALL INTERIOR FIRE-RATED PARTITIONS SHALL EXTEND TO DECK ABOVE (w/ SMOKE-TIGHT SEAL) OR SHALL TERMINATE AT ASSEMBLIES OF GREATER OR EQUAL RATING. NON FIRE-RATED PARTITIONS SHALL NOT PENETRATE FIRE-RATED PARTITIONS. AT FIRE-RATED AREAS, THE STRUCTURE OR CEILING SYSTEM SHALL BE RATED TO PROVIDE A FIRE-RATED OCCUPIED ENVELOPE. NEW GYP. BD. ABUTTING OTHER MATERIALS OR EXISTING FINISHES IS TO BE FINISHED w/ METAL EDGES. GYP. BD. @ STL. STUD FURR-OUTS IN AREAS w/ FINISHED CEILING SHOULD EXTEND TO 4-INCHES MINIMUM ABOVE FINISH CEILING AND BE BRACED WITH DIAGONAL MEMBERS SECURED TO STRUCTURE ABOVE @ 8FT. o.c. (MIN.) EXISTING DOORS & FRAMES THAT ARE TO BE REUSED SHALL BE CLEANED AND REFINISHED. ANY EXISTING DOOR THAT IS LABELED AS FIRE-RATED ON THE NEW LIFE SAFETY DWGS. SHALL BE FIELD VERIFIED BY THE CONTRACTOR. IF IT DOES NOT CONFORM TO THE REQUIRED RATING THEN IT IS TO BE REPLACED WITH A NEW DOOR TO MATCH WITH THE APPROPRIATE RATING 25. 26. 27. 28. 29. 30. 31. EQUIPMENT AND FURNISHINGS SUPPLIERS SHALL FIELD VERIFY ALL DIMENSIONS FOR NEW ITEMS BEFORE FABRICATION AND INSTALLATION. SHOP DRAWINGS SHALL CONTAIN VERIFIED DIMENSIONS. 32. ALL EXISTING WD. DECK TO BE PAINTED w/ FIRE RETARDANT INTUMESCENT PAINT. 33. ABBREVIATIONS A.C.T. ACOUSTICAL CEILING TILE ADJ. ADJUSTABLE A.F.F. ABOVE FINISH FLOOR ALT. ALTERNATE ALUM. ALUMINUM ARCH. ARCHITECT BM. BEAM BLK. BLOCK BLKG. BLOCKING BLDG. BUILDING CEM. CEMENT C.F.S. CLEAR FLOOR SPACE C.J. CONTROL JOINT CL CENTER LINE CMU CONCRETE MASONRY UNIT CLR. CLEAR CLG. CEILING C.O. CASED OPENING COL. COLUMN CONC. CONCRETE CONSTR. CONSTRUCTION CONT. CONTINUOUS C.P.C.I. CONTRACTOR PROVIDED, CONTRACTOR INSTALLED DBL. DOUBLE DET. DETAIL DIA. DIAMETER DIAG. DIAGONAL DIM. DIMENSION DWG. DRAWING EA. EACH EL. ELEVATION EQ. EQUAL EQUIP. EQUIPMENT EXST. EXISTING EXP. EXPANSION EXT. EXTERIOR F.C. FILE CABINET FEC FIRE EXTINGUISHER CABINET FIN. FINISH FLR. FLOOR FRMG. FRAMING FT. FOOT GA. GAUGE GT. GROUT GYP. GYPSUM GYP. BD. GYPSUM BOARD HAZ. HAZARDOUS HCWD HOLLOW CORE WOOD DOOR HDR. HEADER HDW HARDWARE HMD HOLLOW METAL DOOR HNDRL. HANDRAIL HORIZ. HORIZONTAL HT. HEIGHT ICR INTERCHANGABLE CLASS ROOM IN. INCH INCL. INCLUDED INT. INTERIOR JAN. JANITOR JT. JOINT LAM. LAMINATE LAV. LAVATORY LBR. LUMBER LKR. LOCKER LMST. LIMESTONE LVR. LOUVER MAT. MATERIAL MAX. MAXIMUM MEZZ. MEZZAININE MIN. MINIMUM M.O. MASONRY OPENING MOD. BIT. MODIFIED BITUMEN M.R. MOISTURE RESISTANT MTL. METAL MTLR METAL ROOF MWP MEMBRANE WATERPROOFING N.I.C. NOT IN CONTRACT NOM. NOMINAL N.T.S. NOT TO SCALE O.C. ON CENTER O.P.C.I. OWNER PROVIDED, CONTRACTOR INSTALLED OPNG. OPENING OPP. OPPOSITE PLAM. PLASTIC LAMINATE PLYWD. PLYWOOD PNL. PANEL PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH P.T. PRESURE TREATED R. RADIUS REINF. REINFORCE REQD. REQUIRED REST. RESTROOM RLG. RAILING RM. ROOM R.O. ROUGH OPENING RTU ROOF TOP UNIT R.V. ROOF VENT S.C. SOLID CORE SCHED. SCHEDULE SCWD SOLID CORE WOOD DOOR SECT. SECTION SHT. SHEET SIM. SIMILAR SPEC. SPECIFICATIONS STD. STANDARD STL. STEEL STRUCT. STRUCTURAL SQ. SQUARE THK. THICK T.H. THRESHOLD TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE VERT. VERTICAL V.I.F. VERIFY IN FIELD W.P. WATERPROOF WT. WEIGHT W.W.F. WELDED WIRE FABRIC W/ WITH WD. WOOD ADA DISCLAIMER: ALL CONSTRUCTION ACTIVITIES SHALL BE COMPLETED IN FULL COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT ("ADA") AND ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD, FEDERAL REGISTER 36 CFR PARTS 1190 AND 1191, ACCESSIBLE GUIDELINES FOR BUILDINGS AND FACILITIES; ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES; PROPOSED RULE, PUBLISHED IN THE FEDERAL REGISTER ON JULY 23, 2004, AS HAS BEEN ADOPTED BY METRO. DRAWING INDEX SHEET NO SHEET NAME CD 03.18.16 REVISION #1 - 04.01.16 REVISION #2 - 04.21.16 E0.1 ELECTRICAL - LEGEND & SPECS X E0.2 ELECTRICAL - SCHEDULES & RISER X E0.3 ELECTRICAL - PANELBOARDS X X E1.0 LOWER LEVEL - LIGHTING X E1.1 FIRST FLOOR - AREA 'A' LIGHTING X E1.2 FIRST FLOOR - AREA 'B' LIGHTING X E1.3 FIRST FLOOR - AREA 'C' LIGHTING X E2.0 LOWER LEVEL - POWER / SYSTEMS X E2.1 FIRST FLOOR - AREA 'A' POWER / SYSTEMS X E2.2 FIRST FLOOR - AREA 'B' POWER / SYSTEMS X E2.3 FIRST FLOOR - AREA 'C' POWER / SYSTEMS X X E3.0 LOWER LEVEL - HVAC POWER / FA SUSTEMS X E3.1 FIRST FLOOR - AREA 'A' HVAC POWER / FA SYSTEMS X E3.2 FIRST FLOOR - AREA 'B' HVAC POWER / FA SYSTEMS X E3.3 FIRST FLOOR - AREA 'C' HVAC POWER / FA SYSTEMS X E4.1 ELECTRICAL - DETAILS X E4.2 ELECTRICAL - DETAILS X FP0.1 LEGEND & SCHEDULES - FIRE PROTECTION X FP1.1 LOWER LEVEL DEMOLITION X FP1.2 FIRST FLOOR AREA 'A' RENOVATION X FP1.3 FIRST FLOOR AREA 'B' RENOVATION X FP1.4 FIRST FLOOR AREA 'C' RENOVATION X FP1.5 LOWER LEVEL - RENOVATION X FP2.1 DETAILS - FIRE PROTECTION X DRAWING INDEX SHEET NO SHEET NAME CD 03.18.16 REVISION #1 - 04.01.16 REVISION #2 - 04.21.16 G0.0 COVER SHEET X G0.5 CODE REVIEW X X G1.0 DRAWING INDEX / GENERAL INFO. X X X G1.1 LOWER LEVEL - LIFE SAFETY PLANS X X G1.2 FIRST FLOOR - AREA 'A' LIFE SAFETY PLAN X G1.3 FIRST FLOOR - AREA 'B' LIFE SAFETY PLAN X G1.4 FIRST FLOOR - AREA 'C' LIFE SAFETY PLAN X G1.6 TYP. INTERIOR WALL PARTITIONS X X G1.7 TYP. UL RATING INFO. X A0.0 EXISTING SITE PLAN - SIDEWALKS X X A1.0 OVERALL PLANS - DEMOLITION X A1.1 OVERALL PLANS - RENOVATION X A1.2 LOWER LEVEL - DEMOLITION X X A1.3 FIRST FLOOR - AREA 'A' DEMOLITION X A1.4 FIRST FLOOR - AREA 'B' DEMOLITION X X A1.5 FIRST FLOOR - AREA 'C' DEMOLITION X X A1.6 LOWER LEVEL - RENOVATION X X X A1.7 FIRST FLOOR - AREA 'A' RENOVATION X X X A1.8 FIRST FLOOR AREA 'B' RENOVATION X X X A1.9 FIRST FLOOR AREA 'C' RENOVATION X X X A1.11 LOWER LEVEL- DIMENSIONED X X A1.12 FIRST FLOOR - AREA 'A' DIMENSIONED X A1.13 FIRST FLOOR - AREA 'B' DIMENSIONED X A1.14 FIRST FLOOR - AREA 'C' DIMENSIONED X A1.16 LOWER LEVEL - RCP X X A1.17 FIRST FLOOR - AREA 'A' RCP X A1.18 FIRST FLOOR - AREA 'B' RCP X A1.19 FIRST FLOOR - AREA 'C' RCP X A2.0 EXTERIOR ELEVATIONS X X A3.0 WALL SECTIONS X X A4.0 ENLARGED PLANS - TOILETS X X A4.2 ENLARGED PLANS - CASEWORK X A4.3 ENLARGED PLANS - CASEWORK X A4.4 STAIR DETAILS X A4.5 ROOF PLAN, DETAILS & MISC. FLASHING DETAILS X A6.0 DOOR SCHEDULES X X X A6.1 DOOR SCHEDULES X X X A6.2 WINDOW SCHEDULE & OPENING DETAILS X X A7.0 LOWER LEVEL FINISH PLAN X X A7.1 FIRST FLOOR AREA 'A' FINISH PLAN X X A7.2 FIRST FLOOR AREA 'B' FINISH PLAN X X A7.3 FIRST FLOOR AREA 'C' FINISH PLAN X X FS1 FOOD SERVICES - EQUIPMENT PLAN X S0.1 GENERAL NOTES X S1.1 FOUNDATION PLAN X X S1.2 ROOF PLAN X S2.1 FOUNDATION DETAILS X X S2.2 FOUNDATION DETAILS X S3.1 FRAMING DETAILS X M0.1 LEGEND & SCHEDULES - HVAC X M0.02 SCHEDULES - HVAC X M1.1 FIRST FLOOR AREA 'A' DEMOLITION X M1.2 FIRST FLOOR AREA 'B' DEMOLITION X M1.3 FIRST FLOOR AREA 'C' DEMOLITION X M1.4 LOWER LEVEL DEMOLITION X M1.5 FIRST FLOOR AREA 'A' RENOVATION X M1.6 FIRST FLOOR AREA 'B' RENOVATION X X M1.7 FIRST FLOOR AREA 'C' RENOVATION X M1.8 LOWER LEVEL - RENOVATION X M2.1 DETAILS - HVAC X M2.2 DETAILS - HVAC X M3.1 SPECIFICATIONS - HVAC X P0.1 LEGEND & SCHEDULES X P1.1 FIRST FLOOR AREA 'A' DEMOLITION X P1.2 FIRST FLOOR AREA 'B' DEMOILITION X P1.3 FIRST FLOOR AREA 'C' DEMOLITION X P1.4 LOWER LEVEL - DEMOLITION X P1.5 FIRST FLOOR AREA 'A' RENOVATION X P1.6 FIRST FLOOR AREA 'B' RENOVATION X P1.7 FIRST FLOOR AREA 'C' RENOVATION X P1.8 LOWER LEVEL - RENOVATION X P1.9 KITCHEN AREA RENOVATION X P2.1 SPECIFICATIONS - PLUMBING X ARCHITECTURAL: GENERAL: DATE: PROJECT NUMBER: DRAWING NUMBER: SHEET TITLE: REVISIONS: PROJECT TITLE: DRAWN BY: NASHVILLE * DENVER * SAN ANTONIO SAN FRANCISCO * PALM BEACH GARDEN 615.254.8500 * GHP1.com 217th FIFTH AVENUE NORTH NASHVILLE, TN. 37219 1 2 3 4 5 E D C B A E D C B A 1 2 3 4 5 60 MUSIC SQUARE EAST SUITE 300 NASHVILLE, TN 37203 PH: 615.383.6949 1162 FOSTER AVENUE NASHVILLE, TN 37210 PH: 615.921.2200 G1.0 DRAWING INDEX / GENERAL INFO. 03.18.2016 13093.09 1252 FOSTER AVE, NASHVILLE, TN 37210 STEM PREPARATORY ACADEMY HIGH SCHOOL RENOVATION C.D. FOOD SERVICES: PLUMBING: ELECTRICAL: MECHANICAL: STRUCTURAL: DRAWING INDEX NOTE : THE FOLLOWING SHEETS HAVE BEEN OMITTED IN ANTICIPATION OF ALTERNATE #1 - ADDITION TO BE PUBLISHED IN THE FUTURE: A1.10; A1.15; A1.20; A3.1; A4.1; A7.4 & G1.5 FIRE PROTECTION: 1 REVISION #1 - 04.01.2016 2 REVISION #2 - 04.21.2016

Upload: others

Post on 04-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

GENERAL NOTES

FLOOR PLANS WERE PROVIDED BY THE OWNER AND MAY NOT REFLECT REVISIONS MADE DURINGCONSTRUCTION OR RENOVATION MADE AFTERWARDS. INFORMATION SHOWN PERTAINING TO EXISTINGCONDITIONS IS BASED UPON VISUAL INSPECTION AND EXISTING CONSTRUCTION DOCUMENTS USED BYTHE ARCHITECT. ANY DISCREPANCIES DISCOVERED BY OTHERS SHALL BE BROUGHT TO THE ATTENTIONOF THE ARCHITECT PRIOR TO BEGINNING WORK.

2.

ALL INTERIOR DIMENSIONS ON PLAN SHEETS ARE....A: FACE OF STUD TO FACE OF STUD, (EXCLUSIVE OF FINISH MAT'L) UNLESS

OTHERWISE NOTED.B: FACE OF STUD TO FACE OF EXISTING WALL, UNLESS OTHERWISE NOTED.C: ALL INTERIOR STUDS TO BE SPACED @ 1' - 4" o.c. UNLESS OTHERWISE

NOTED.

3.

GC TO COORDINATE ADDITIONAL NOTES AND DIMENSIONS BETWEEN 1/8" SCALE AND ENLARGED PLANS.

4.

SEE LIFE SAFETY PLANS FOR FIRE RATED PARTITIONS.

5.

UNLESS OTHERWISE NOTED, OWNER TO PROVIDE INTERIOR ROOM SIGNAGE. CONTRACTOR TOCOORDINATE INSTALLATION w/SIGN VENDOR.

6.

SEE PLUMBING PLANS FOR FLOOR DRAIN LOCATIONS. PROVIDE POSITIVE DRAINAGE TO FLOORDRAIN. COORDINATE WITH ALL TRADES.

7.

IN THE EVENT OF ANY DISCREPANCIES AND / OR ERRORS FOUND IN THE DRAWINGS, OR IF PROBLEMSARE ENCOUNTERED DURING DEMOLITION. THE CONTRACTOR SHALL BE REQ'D TO NOTIFY THEDESIGNER BEFORE PROCEEDING WITH THE WORK. IF THE DESIGNER IS NOT NOTIFIED, THECONTRACTOR SHALL TAKE RESPONSIBILITY FOR THE COST OF ANY REVISION.

8.

IN THE EVENT THAT THERE ARE QUESTIONS CONCERNING THE HANDLING OF ANY CONTAMINATEDMATERIALS, THE CONTRACTOR SHALL COORDINATE SUCH ISSUES WITH THE OWNERS REPRESENTATIVE.ALL MATERIALS SHALL BE HANDLED FOR DISPOSAL PROPERLY IN ACCORDANCE WITH ALL APPLICABLELAWS AND REGULATIONS AT APPROVED FACILITIES WHICH ARE LICENSED AND / OR APPROVED FOR THEDISPOSAL OF OR HANDLING OF SUCH MATERIALS.

9.

THIS WORK CONSISTS OF CLEARING, REMOVING AND DISPOSING OF ALL BLDG. DEMOLITIONDEBRIS AND UTILITIES NOT REMOVED BY OTHERS THAT ARE WITHIN DESIGNATED PROJECTAREAS EXCEPT FOR SUCH OBJECTS THAT THE DESIGNER DESIGNATES TO REMAIN. THE WORKSHALL ALSO INCLUDE PRESERVING AND PROTECTING FROM INJURY OR DEFACEMENT OF ALLVEGETATION, STRUCTURE & OBJECTS DESIGNATED TO REMAIN.

10.

CONTRACTOR TO COORDINATE ALL UTILITY DEMOLITION AND REMOVAL WITH PROPER AGENCIES.

11.

CONTRACTOR TO COORDINATE WITH THE RESPECTIVE UTILITIES TO HAVE ALL UTILITY SERVICESREMOVED OR DISCONNECTED PRIOR TO THE COMMENCEMENT OF ANY DISCONNECTED, CAPPED OFF,PLUGGED OR OTHERWISE SECURED UTILITIES. CARE SHALL BE EXERCISED SO AS NOT TO DAMAGE ANYMAIN UTILITY LINES DUE TO DEMOLITION ACTIVITIES AND ANY SUCH DAMAGES WILL BE REPAIRED TO THEREQUIREMENTS OF THE RESPECTIVE UTILITY AR THE CONTRACTORS EXPENSE. ASSURE PROPERFUNCTION OF REMAINING UTILITIES UPON COMPLETION & REWORK.

12.

CONTRACTOR SHALL MAKE ALL NOTIFICATIONS AND OBTAIN ALL PERMITS ASSOCIATED WITH THEDEMOLITION / REMOVAL OF BUILDINGS AND ANY RELATED APPURTENANCES.

13.

PRIOR TO DEMOLITION OF ANY EXISTING CONSTRUCTION / ELEMENTS / EQUIPMENT ON ANY TRACT ORLOT, CONTRACTOR SHALL INSURE THAT ANY AND ALL HAZARDOUS MATERIALS INCLUDING BUT NOTLIMITED TO FRIABLE ASBESTOS CONTAINING MATERIAL SHALL BE HANDLED IN ACCORDANCE WITH ALLLOCAL, STATE, AND FEDERAL REQUIREMENTS. THIS INCLUDES ANY NOTIFICATIONS AND PERMITSREQ'D.

14.

ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE NATIONAL EMISSION STANDARDS FORHAZARDOUS AIR POLLUTANTS (NESHAP) PROMULGATED BY THE UNITED STATES ENVIRONMENTALPROTECTION AGENCY (USEPA), AND THE OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA).

15.

CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL MEASURES NECESSARY TO INCLUDE SILTFENCES AND INLET PROTECTION WHERE WATER DRAINS OFF DISTURBED AREAS, SEDIMENT ANDEROSION CONTROL MEASURES SHALL BE IN PLACE PRIOR TO DEMOLITION OR CONSTRUCTIONACTIVITIES.

16.

CONTRACTOR SHALL NOT DISTURB EXISTING CONDITIONS OUTSIDE LIMITS OF WORK UNLESSOTHERWISE NOTED; ANY DAMAGES INCURRED WILL BE REPAIRED AT CONTRACTOR'S EXPENSE.

17.

THE ABBREVIATION G.C. WHERE SHOWN ON THE DRAWINGS, SHALL MEAN GENERAL CONTRACTOR.

18.

THE G.C. SHALL SEAL ALL OPENINGS AROUND PIPES, DUCTWORK, ETC. THAT PENETRATE PARTITIONSABOVE THE FINISHED CEILING. ALL WORK AND SEALANT MATERIAL SHALL BE APPROVED BYARCHITECT.

19.

THE G.C. SHALL PROVIDE ALL REQUIRED FIRE EXTINGUISHERS.

20.

ALL EXTERIOR WALLS AND INTERIOR PARTITIONS SHALL EXTEND TO UNDERSIDE OF ROOF OR FLOORDECK UNLESS NOTED OTHERWISE.

21.

VERIFY SIZE AND LOCATION OF ALL LOUVERS, OPENINGS, AND CONCRETE PADS REQUIREDBY THE HEATING CONTRACTOR. HEATING CONTRACTOR TO CONDUCT COORDINATIONMEETINGS w/ ALL DISCIPLINES.

22.

EQUIPMENT, CABINETRY AND FURNISHINGS SUPPLIERS SHALL FIELD VERIFY ALL DIMENSIONS FORNEW ITEMS BEFORE FABRICATION AND INSTALLATION. SHOP DRAWING SHALL CONTAIN VERIFIEDDIMENSIONS WHERE POSSIBLE.

23.

G.C. TO INSTALL WOOD OR METAL BLOCKING AS REQUIRED FOR INSTALLATION OF CASEWORK.MILLWORK, GRAB BARS, AND ANY OTHER ITEMS THAT REQUIRE SECURE ATTACHMENT TO WALLSAND/OR CEILINGS.

24.

CONTRACTORS SHALL NOTE THAT MATERIALS CONTAINING ASBESTOS MAY BE ENCOUNTERED WHENWORKING IN THE EXISTING BUILDING. CONTRACTORS SHALL COORDINATE THEIR WORK WITH THE OWNER.ALL ASBESTOS RELATED WORK SHALL BE COMPLETED BY THE ASBESTOS ABATEMENT CONTRACTOR.

1.

PERFORM WORK AS REQ'D FOR PROPER COMPLETION OF THE WORK. THE DRAWINGS MAY NOTSHOW ALL EXISTING ITEMS OR CONDITIONS. CONTRACTOR SHALL NOT REC'V EXTRA PAYMENTFOR REQUIREMENTS WHICH CAN BE INFERRED THROUGH OBSERVATION OF EXISTINGCONDITIONS AT THE SITE. IN THE EVENT CONCEALED CONDITIONS ARE ENCOUNTERED, WHICHMAY VARY SIGNIFICANTLY FROM THOSE INDICATED ON THE DRAWINGS, NOTIFY THE ARCHITECTBEFORE PROCEEDING WITH THE WORK.

DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCEOVER SCALED DIMENSIONS. ENLARGED PLANS SHALL HAVE PRECEDENCE OVER SMALL-SCALE PLANS.CONTRACTOR SHALL FIELD VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ON THE JOB SITE.

WHERE WORK IS PERFORMED IN EXISTING AREAS, THE EXISTING FINISHED CONDITIONS ARE TO BEREPAIRED OR REPLACED. THESE FINISHED CONDITIONS ARE TO MATCH EXISTING UNLESSOTHERWISE NOTED. WHERE NEW FINISHED CONDITIONS ARE TO BE INSTALLED, EXISTING FINISHEDCONDITIONS ARE TO BE REMOVED BY THE CONTRACTOR AND APPROPRIATE PREPARATION OFSUBSTRATE SHALL BE COMPLETED FOR SPECIFIED FINISH.

ALL INTERIOR FIRE-RATED PARTITIONS SHALL EXTEND TO DECK ABOVE (w/ SMOKE-TIGHT SEAL) ORSHALL TERMINATE AT ASSEMBLIES OF GREATER OR EQUAL RATING. NON FIRE-RATED PARTITIONSSHALL NOT PENETRATE FIRE-RATED PARTITIONS. AT FIRE-RATED AREAS, THE STRUCTURE ORCEILING SYSTEM SHALL BE RATED TO PROVIDE A FIRE-RATED OCCUPIED ENVELOPE.

NEW GYP. BD. ABUTTING OTHER MATERIALS OR EXISTING FINISHES IS TO BE FINISHED w/ METALEDGES.

GYP. BD. @ STL. STUD FURR-OUTS IN AREAS w/ FINISHED CEILING SHOULD EXTEND TO 4-INCHESMINIMUM ABOVE FINISH CEILING AND BE BRACED WITH DIAGONAL MEMBERS SECURED TO STRUCTUREABOVE @ 8FT. o.c. (MIN.)

EXISTING DOORS & FRAMES THAT ARE TO BE REUSED SHALL BE CLEANED AND REFINISHED. ANYEXISTING DOOR THAT IS LABELED AS FIRE-RATED ON THE NEW LIFE SAFETY DWGS. SHALL BE FIELDVERIFIED BY THE CONTRACTOR. IF IT DOES NOT CONFORM TO THE REQUIRED RATING THEN IT IS TO BEREPLACED WITH A NEW DOOR TO MATCH WITH THE APPROPRIATE RATING

25.

26.

27.

28.

29.

30.

31.

EQUIPMENT AND FURNISHINGS SUPPLIERS SHALL FIELD VERIFY ALL DIMENSIONS FOR NEW ITEMSBEFORE FABRICATION AND INSTALLATION. SHOP DRAWINGS SHALL CONTAIN VERIFIED DIMENSIONS.

32.

ALL EXISTING WD. DECK TO BE PAINTED w/ FIRE RETARDANT INTUMESCENT PAINT.33.

ABBREVIATIONS

A.C.T. ACOUSTICAL CEILING TILEADJ. ADJUSTABLE A.F.F. ABOVE FINISH FLOORALT. ALTERNATEALUM. ALUMINUMARCH. ARCHITECTBM. BEAMBLK. BLOCKBLKG. BLOCKINGBLDG. BUILDINGCEM. CEMENTC.F.S. CLEAR FLOOR SPACEC.J. CONTROL JOINTCL CENTER LINECMU CONCRETE MASONRY UNITCLR. CLEARCLG. CEILINGC.O. CASED OPENINGCOL. COLUMNCONC. CONCRETECONSTR. CONSTRUCTIONCONT. CONTINUOUSC.P.C.I. CONTRACTOR PROVIDED, CONTRACTOR INSTALLEDDBL. DOUBLEDET. DETAILDIA. DIAMETERDIAG. DIAGONALDIM. DIMENSIONDWG. DRAWINGEA. EACHEL. ELEVATIONEQ. EQUALEQUIP. EQUIPMENTEXST. EXISTINGEXP. EXPANSIONEXT. EXTERIORF.C. FILE CABINETFEC FIRE EXTINGUISHER CABINETFIN. FINISHFLR. FLOORFRMG. FRAMINGFT. FOOTGA. GAUGEGT. GROUTGYP. GYPSUMGYP. BD. GYPSUM BOARDHAZ. HAZARDOUSHCWD HOLLOW CORE WOOD DOORHDR. HEADERHDW HARDWAREHMD HOLLOW METAL DOORHNDRL. HANDRAILHORIZ. HORIZONTALHT. HEIGHTICR INTERCHANGABLE CLASS ROOMIN. INCHINCL. INCLUDEDINT. INTERIORJAN. JANITORJT. JOINTLAM. LAMINATELAV. LAVATORYLBR. LUMBERLKR. LOCKERLMST. LIMESTONELVR. LOUVERMAT. MATERIALMAX. MAXIMUMMEZZ. MEZZAININEMIN. MINIMUMM.O. MASONRY OPENINGMOD. BIT. MODIFIED BITUMENM.R. MOISTURE RESISTANTMTL. METALMTLR METAL ROOFMWP MEMBRANE WATERPROOFINGN.I.C. NOT IN CONTRACTNOM. NOMINALN.T.S. NOT TO SCALEO.C. ON CENTERO.P.C.I. OWNER PROVIDED, CONTRACTOR INSTALLEDOPNG. OPENINGOPP. OPPOSITEPLAM. PLASTIC LAMINATEPLYWD. PLYWOODPNL. PANELPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHP.T. PRESURE TREATEDR. RADIUSREINF. REINFORCEREQD. REQUIREDREST. RESTROOMRLG. RAILINGRM. ROOMR.O. ROUGH OPENINGRTU ROOF TOP UNITR.V. ROOF VENTS.C. SOLID CORESCHED. SCHEDULESCWD SOLID CORE WOOD DOORSECT. SECTIONSHT. SHEETSIM. SIMILARSPEC. SPECIFICATIONSSTD. STANDARDSTL. STEELSTRUCT. STRUCTURALSQ. SQUARETHK. THICKT.H. THRESHOLDTYP. TYPICALU.N.O. UNLESS NOTED OTHERWISEVERT. VERTICALV.I.F. VERIFY IN FIELDW.P. WATERPROOFWT. WEIGHTW.W.F. WELDED WIRE FABRICW/ WITHWD. WOOD

ADA DISCLAIMER:ALL CONSTRUCTION ACTIVITIES SHALL BE COMPLETED IN FULL COMPLIANCEWITH THE AMERICANS WITH DISABILITIES ACT ("ADA") AND ARCHITECTURALAND TRANSPORTATION BARRIERS COMPLIANCE BOARD, FEDERAL REGISTER36 CFR PARTS 1190 AND 1191, ACCESSIBLE GUIDELINES FOR BUILDINGS ANDFACILITIES; ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY GUIDELINES;PROPOSED RULE, PUBLISHED IN THE FEDERAL REGISTER ON JULY 23, 2004,AS HAS BEEN ADOPTED BY METRO.

DRAWING INDEX

SHEET NO SHEET NAME CD

03.

18.1

6

RE

VIS

ION

#1

- 04

.01.

16

RE

VIS

ION

#2

- 04

.21.

16

E0.1 ELECTRICAL - LEGEND & SPECS XE0.2 ELECTRICAL - SCHEDULES & RISER XE0.3 ELECTRICAL - PANELBOARDS X XE1.0 LOWER LEVEL - LIGHTING XE1.1 FIRST FLOOR - AREA 'A' LIGHTING XE1.2 FIRST FLOOR - AREA 'B' LIGHTING XE1.3 FIRST FLOOR - AREA 'C' LIGHTING XE2.0 LOWER LEVEL - POWER / SYSTEMS XE2.1 FIRST FLOOR - AREA 'A' POWER / SYSTEMS XE2.2 FIRST FLOOR - AREA 'B' POWER / SYSTEMS XE2.3 FIRST FLOOR - AREA 'C' POWER / SYSTEMS X XE3.0 LOWER LEVEL - HVAC POWER / FA SUSTEMS XE3.1 FIRST FLOOR - AREA 'A' HVAC POWER / FA SYSTEMS XE3.2 FIRST FLOOR - AREA 'B' HVAC POWER / FA SYSTEMS XE3.3 FIRST FLOOR - AREA 'C' HVAC POWER / FA SYSTEMS XE4.1 ELECTRICAL - DETAILS XE4.2 ELECTRICAL - DETAILS X

FP0.1 LEGEND & SCHEDULES - FIRE PROTECTION XFP1.1 LOWER LEVEL DEMOLITION XFP1.2 FIRST FLOOR AREA 'A' RENOVATION XFP1.3 FIRST FLOOR AREA 'B' RENOVATION XFP1.4 FIRST FLOOR AREA 'C' RENOVATION XFP1.5 LOWER LEVEL - RENOVATION XFP2.1 DETAILS - FIRE PROTECTION X

DRAWING INDEX

SHEET NO SHEET NAME CD

03.

18.1

6

RE

VIS

ION

#1

- 04

.01.

16

RE

VIS

ION

#2

- 04

.21.

16

G0.0 COVER SHEET XG0.5 CODE REVIEW X XG1.0 DRAWING INDEX / GENERAL INFO. X X XG1.1 LOWER LEVEL - LIFE SAFETY PLANS X XG1.2 FIRST FLOOR - AREA 'A' LIFE SAFETY PLAN XG1.3 FIRST FLOOR - AREA 'B' LIFE SAFETY PLAN XG1.4 FIRST FLOOR - AREA 'C' LIFE SAFETY PLAN XG1.6 TYP. INTERIOR WALL PARTITIONS X XG1.7 TYP. UL RATING INFO. X

A0.0 EXISTING SITE PLAN - SIDEWALKS X XA1.0 OVERALL PLANS - DEMOLITION XA1.1 OVERALL PLANS - RENOVATION XA1.2 LOWER LEVEL - DEMOLITION X XA1.3 FIRST FLOOR - AREA 'A' DEMOLITION XA1.4 FIRST FLOOR - AREA 'B' DEMOLITION X XA1.5 FIRST FLOOR - AREA 'C' DEMOLITION X XA1.6 LOWER LEVEL - RENOVATION X X XA1.7 FIRST FLOOR - AREA 'A' RENOVATION X X XA1.8 FIRST FLOOR AREA 'B' RENOVATION X X XA1.9 FIRST FLOOR AREA 'C' RENOVATION X X XA1.11 LOWER LEVEL- DIMENSIONED X XA1.12 FIRST FLOOR - AREA 'A' DIMENSIONED XA1.13 FIRST FLOOR - AREA 'B' DIMENSIONED XA1.14 FIRST FLOOR - AREA 'C' DIMENSIONED XA1.16 LOWER LEVEL - RCP X XA1.17 FIRST FLOOR - AREA 'A' RCP XA1.18 FIRST FLOOR - AREA 'B' RCP XA1.19 FIRST FLOOR - AREA 'C' RCP XA2.0 EXTERIOR ELEVATIONS X XA3.0 WALL SECTIONS X XA4.0 ENLARGED PLANS - TOILETS X XA4.2 ENLARGED PLANS - CASEWORK XA4.3 ENLARGED PLANS - CASEWORK XA4.4 STAIR DETAILS XA4.5 ROOF PLAN, DETAILS & MISC. FLASHING DETAILS XA6.0 DOOR SCHEDULES X X XA6.1 DOOR SCHEDULES X X XA6.2 WINDOW SCHEDULE & OPENING DETAILS X XA7.0 LOWER LEVEL FINISH PLAN X XA7.1 FIRST FLOOR AREA 'A' FINISH PLAN X XA7.2 FIRST FLOOR AREA 'B' FINISH PLAN X XA7.3 FIRST FLOOR AREA 'C' FINISH PLAN X X

FS1 FOOD SERVICES - EQUIPMENT PLAN X

S0.1 GENERAL NOTES XS1.1 FOUNDATION PLAN X XS1.2 ROOF PLAN XS2.1 FOUNDATION DETAILS X XS2.2 FOUNDATION DETAILS XS3.1 FRAMING DETAILS X

M0.1 LEGEND & SCHEDULES - HVAC XM0.02 SCHEDULES - HVAC XM1.1 FIRST FLOOR AREA 'A' DEMOLITION XM1.2 FIRST FLOOR AREA 'B' DEMOLITION XM1.3 FIRST FLOOR AREA 'C' DEMOLITION XM1.4 LOWER LEVEL DEMOLITION XM1.5 FIRST FLOOR AREA 'A' RENOVATION XM1.6 FIRST FLOOR AREA 'B' RENOVATION X XM1.7 FIRST FLOOR AREA 'C' RENOVATION XM1.8 LOWER LEVEL - RENOVATION XM2.1 DETAILS - HVAC XM2.2 DETAILS - HVAC XM3.1 SPECIFICATIONS - HVAC X

P0.1 LEGEND & SCHEDULES XP1.1 FIRST FLOOR AREA 'A' DEMOLITION XP1.2 FIRST FLOOR AREA 'B' DEMOILITION XP1.3 FIRST FLOOR AREA 'C' DEMOLITION XP1.4 LOWER LEVEL - DEMOLITION XP1.5 FIRST FLOOR AREA 'A' RENOVATION XP1.6 FIRST FLOOR AREA 'B' RENOVATION XP1.7 FIRST FLOOR AREA 'C' RENOVATION XP1.8 LOWER LEVEL - RENOVATION XP1.9 KITCHEN AREA RENOVATION XP2.1 SPECIFICATIONS - PLUMBING X

ARCHITECTURAL:

GENERAL:

DATE:

PROJECTNUMBER:

DRAWING NUMBER:

SHEET TITLE:

REVISIONS:

PROJECT TITLE:

DRAWN BY:

NASHVILLE * DENVER * SAN ANTONIO

SAN FRANCISCO * PALM BEACH GARDEN

615.254.8500 * GHP1.com

217th FIFTH AVENUE NORTHNASHVILLE, TN. 37219

1

2

3

4

5

E D C B A

E D C B A

1

2

3

4

5

60 MUSIC SQUARE EASTSUITE 300

NASHVILLE, TN 37203PH: 615.383.6949

1162 FOSTER AVENUENASHVILLE, TN 37210

PH: 615.921.2200

G1.0

DRAWING INDEX /GENERAL INFO.

03.18.2016

13093.09

1252 FOSTER AVE,NASHVILLE, TN 37210

STEMPREPARATORYACADEMY

HIGH SCHOOLRENOVATION

C.D.

FOOD SERVICES:

PLUMBING:

ELECTRICAL:

MECHANICAL:

STRUCTURAL:

DRAWING INDEX NOTE: THE FOLLOWING SHEETS HAVE BEEN OMITTED IN ANTICIPATION OF ALTERNATE #1- ADDITION TO BE PUBLISHED IN THE FUTURE: A1.10; A1.15; A1.20; A3.1; A4.1; A7.4 & G1.5

FIRE PROTECTION:

1 REVISION #1 - 04.01.2016

2 REVISION #2 - 04.21.2016

Page 2: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

AREA OF WORK

AREA OF WORK

LOWER LEVEL - KEY PLAN

CRAWL SPACE

CR

AW

L S

PA

CE

CRAWL SPACE

STAIRS

101 MECH

003VESTIBULE

004

COPY / WORKAREA

005

I.C.R.

006I.C.R.

007

CORRIDOR

002

VESTIBULE

009

MECH

010

J.C.

011

TLT

012

TLT

013

CORR.

014

MTG. ROOM

015

STAIRS

159

CORR.

016

OFC.

022

OFC.

023

WORK AREA

020

TLT

019

TLT

018

007

006

004

013

012

011

015

018

019

020

022

023

021

024A

01

01

04 05

01

A1

A3.0

P2 P5

P2

P2

P2

P1 P1

P1

P2

P1

P1

P1

P2

P2

P2

P5

VESTIBULE

001

CORRIDOR

008

01

STG

005A

05

005A

P8

P7

I.C.R.

017

I.C.R.

021

I.C.R.

024

017

P1

P1

UP

UP

UP

UP

0303

003

009010

101B

001

002

159A 016A

024B 016C

014

ELECTRICAL

010A

010A

MECH

017A

LOWER LEVEL LIFE SAFETY - WEST

LOWER LEVEL LIFE SAFETY - EAST

09

APPROX. LOCATION OFEXISTING SUMP PUMPS

APPROX. LOCATION OFEXISTING FIRE ENTRANCE

A4.4C1

016B

UP

OFC

005B

005B

05

UP

NEW CODE COMPLIANT HANDRAIL

NEW CODE COMPLIANTHANDRAIL / GUARDRAIL

SEE SHEET A4.0 FOR TYPICALTOILET EQUIPMENT

E

E

SEE SHEET A4.0 FOR TYPICALTOILET EQUIPMENT

P7

11 11

11

11

11

017A

ALT. #3 (SEE SHEET G0.5 FOR ADD'L INFO.)

12

2

GENERAL RENOVATION NOTES:

1. SEE SHEET G1.6 FOR ADD'L INTERIOR PARTITION INFORMATION.

2. SEE SHEET LIFE SAFETY PLANS FOR FIRE RATED PARTITIONS.

3. ALL CMU CORES (NOT FILLED SOLID FOR REINFORCING) SHALL REC'VFOAMED-IN PLACE MASONRY INSULATION. SEE STRUCTURAL FORREINFORCING.

4. ALL WINDOWS ARE TO REC'V NEW WINDOW SHADES AS SPECIFIED. GC TOFIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING SHADES.

WALL LEGEND:

EXISTING WALL SYSTEM

NEW WALL: 3 5/8" STL. STUDS WITH 5/8" GYP. BD. ON EACH FACE.

NON-RATED SMOKE PARTITION

1 HR RATED PARTITION

SEE SHEET G1.6 TYPICAL INTERIOR WALL PARTITIONS FOR ADD'L INFORMATION

HATCH INDICATESAREA OF NEW CONCRETESEE STRUCTURAL

INDICATES LOCATION OF GAS COCK - SEE SHEET A4.1

RENOVATION KEYNOTES:

01 INFILL EXISTING CMU WALL WHERE EXISTING DOORS & FRAME HAVE BEENREMOVED. INFILL TO MATCH SURROUNDING WALL TYPE AND PAINTED /FINISHED TO MATCH. MASONRY INFILL SHALL BE TOOTHED TOGETHER

02 THIS NOTE OMITTED.

03 ALIGN NEW WALL FLUSH w/ EXISTING WALL.

04 NEW CASED OPENING TO BE FINISHED TO MATCH THE SURROUNDINGCONDITIONS

05 NEW CONCRETE FLOOR SLAB AND FOOTINGS - SEE STRUCTURAL

06 INFILL OPENING IN EXISTING EXTERIOR WALL SYSTEM. MATCHSURROUNDING CONSTRUCTION. BRICK TO BE APPROVED BYARCHITECT PRIOR TO CONSTRUCTION

07 NEW CONCRETE PATIO SLAB - SEE STRUCTURAL

08 EXTERIOR BRICK TO BE CLEANED.

09 PROVIDE NEW STL. LINTEL - SEE STRUCTURAL

10 PROVIDE ATTIC ACCESS. WHERE POSSIBLE SAVE / RELOCATE EXISTINGACCESS LADDERS. SEE SHEET A4.4 FOR NEW LADDER DETAILS

11 PROVIDE MANUAL PROJECTION SCREENS AT THE TEACHING WALL OF EACHCLASSROOM (SEE SPECIFICATIONS)

1

DATE:

PROJECTNUMBER:

DRAWING NUMBER:

SHEET TITLE:

REVISIONS:

PROJECT TITLE:

DRAWN BY:

NASHVILLE * DENVER * SAN ANTONIO

SAN FRANCISCO * PALM BEACH GARDEN

615.254.8500 * GHP1.com

217th FIFTH AVENUE NORTHNASHVILLE, TN. 37219

1

2

3

4

5

E D C B A

E D C B A

1

2

3

4

5

60 MUSIC SQUARE EASTSUITE 300

NASHVILLE, TN 37203PH: 615.383.6949

1162 FOSTER AVENUENASHVILLE, TN 37210

PH: 615.921.2200

A1.6

LOWER LEVEL -RENOVATION

03.18.2016

13093.09

1252 FOSTER AVE,NASHVILLE, TN 37210

STEMPREPARATORYACADEMY

HIGH SCHOOLRENOVATION

C.D.

1/8" = 1'-0"C1 LOWER LEVEL - RENOVATION

NORTH

1 REVISION #1 - 04.01.2016

2 REVISION #2 - 04.21.2016

Page 3: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

RE

F.

LOBBY

100

I.C.R.

102

I.C.R.

108

SPEC. ED.

109

BOY'S TLT

107

J.C.

106

GIRL'S TLT

105

I.C.R.

103

STAIRS

101

WORK ROOM /BREAK AREA

118I.C.R.

120

BOY'S TLT

123

J.C.

124

GIRL'S TLT

125

I.C.R.

126

CORR.

122

CORR.

128

I.C.R.

127

I.C.R.

121

I.C.R.

119

MEETING

117

TLT

114

TLT

115

MECH.

112A

MECH.

113A

12312

6

120

118

127

119

107

105

106

109

121

117

114

115

102

108

125

124

103

A4.0E3

Sim

A4.0E3

Sim

A4.0C3

Sim

A4.3E4

0101

01

01

01

01 01

01

0101

01 010101

010101

01

P1

P1

P2

P5

P1

P1

P1P1

P1

P5

P1

P2

P1

P1

P1

P5

P1

P2

CO

RR

IDO

R

104

CORRIDOR

116

P1CORRIDOR

111

RECEPTION

110

ADMIN. / OFC

113

PROFESSIONALDEVELOPMENT

112

112A

112D

113B

113

IT CLST.

113B

UP

UP 101A

101B

104

112B

112C

113A

128A

A4.3B1

10

FILE ROOM

118A

ALL EXTERIOR ELEMENTS OFEXISTING ENTRY ( WALLS, CEILINGSETC.) - PREP & PAINT.

100

118A

INFILL EXISTING WINDOW w/ BRICK& CMU TO MATCH EXISTING

FIELD VERIFY EXACT LOCATIONOF EXISTING WINDOWS TO ENSURENEW WALLS DO NOT CONFLICT w/EXISTING WINDOWS, TYP.

PROVIDE NEW AWNING TOBE SIMILAR IN SIZE w/ EXISTING

DN

SEE SHEET A0.0 FOR ADD'LSIDEWALK / RAMP INFORMATION

11 11

11

11

11

1111

11

11

2

FIRST LEVEL - KEY PLAN

AREA 'A'

GENERAL RENOVATION NOTES:

1. SEE SHEET G1.6 FOR ADD'L INTERIOR PARTITION INFORMATION.

2. SEE SHEET LIFE SAFETY PLANS FOR FIRE RATED PARTITIONS.

3. ALL CMU CORES (NOT FILLED SOLID FOR REINFORCING) SHALL REC'VFOAMED-IN PLACE MASONRY INSULATION. SEE STRUCTURAL FORREINFORCING.

4. ALL WINDOWS ARE TO REC'V NEW WINDOW SHADES AS SPECIFIED. GC TOFIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING SHADES.

RENOVATION KEYNOTES:

01 INFILL EXISTING CMU WALL WHERE EXISTING DOORS & FRAME HAVE BEENREMOVED. INFILL TO MATCH SURROUNDING WALL TYPE AND PAINTED /FINISHED TO MATCH. MASONRY INFILL SHALL BE TOOTHED TOGETHER

02 THIS NOTE OMITTED.

03 ALIGN NEW WALL FLUSH w/ EXISTING WALL.

04 NEW CASED OPENING TO BE FINISHED TO MATCH THE SURROUNDINGCONDITIONS

05 NEW CONCRETE FLOOR SLAB AND FOOTINGS - SEE STRUCTURAL

06 INFILL OPENING IN EXISTING EXTERIOR WALL SYSTEM. MATCHSURROUNDING CONSTRUCTION. BRICK TO BE APPROVED BYARCHITECT PRIOR TO CONSTRUCTION

07 NEW CONCRETE PATIO SLAB - SEE STRUCTURAL

08 EXTERIOR BRICK TO BE CLEANED.

09 PROVIDE NEW STL. LINTEL - SEE STRUCTURAL

10 PROVIDE ATTIC ACCESS. WHERE POSSIBLE SAVE / RELOCATE EXISTINGACCESS LADDERS. SEE SHEET A4.4 FOR NEW LADDER DETAILS

11 PROVIDE MANUAL PROJECTION SCREENS AT THE TEACHING WALL OF EACHCLASSROOM (SEE SPECIFICATIONS)

1

WALL LEGEND:

EXISTING WALL SYSTEM

NEW WALL: 3 5/8" STL. STUDS WITH 5/8" GYP. BD. ON EACH FACE.

NON-RATED SMOKE PARTITION

1 HR RATED PARTITION

SEE SHEET G1.6 TYPICAL INTERIOR WALL PARTITIONS FOR ADD'L INFORMATION

HATCH INDICATESAREA OF NEW CONCRETESEE STRUCTURAL

INDICATES LOCATION OF GAS COCK - SEE SHEET A4.1

DATE:

PROJECTNUMBER:

DRAWING NUMBER:

SHEET TITLE:

REVISIONS:

PROJECT TITLE:

DRAWN BY:

NASHVILLE * DENVER * SAN ANTONIO

SAN FRANCISCO * PALM BEACH GARDEN

615.254.8500 * GHP1.com

217th FIFTH AVENUE NORTHNASHVILLE, TN. 37219

1

2

3

4

5

E D C B A

E D C B A

1

2

3

4

5

60 MUSIC SQUARE EASTSUITE 300

NASHVILLE, TN 37203PH: 615.383.6949

1162 FOSTER AVENUENASHVILLE, TN 37210

PH: 615.921.2200

A1.7

FIRST FLOOR - AREA'A' RENOVATION

03.18.2016

13093.09

1252 FOSTER AVE,NASHVILLE, TN 37210

STEMPREPARATORYACADEMY

HIGH SCHOOLRENOVATION

C.D.

1/8" = 1'-0"B1 FIRST FLOOR - AREA 'A' RENOVATIONNORTHNORTH

1 REVISION #1 - 04.01.2016

2 REVISION #2 - 04.21.2016

Page 4: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

REF.

FIRST LEVEL - KEY PLAN

AREA 'B'

CORR.

139

I.C.R.

140

CORRIDOR

144

I.C.R.

141GIRL'S TLT

143

J.C.

145

BOY'S TLT

146

I.C.R.

142

I.C.R.

147

I.C.R.

148

MECH

149

STG

150

WORK AREA

152

TLT

153

TLT

154

SPEC. ED

151

CORR.

155

SCIENCELECTURE

156

LAB STG

157A

MECH

157B

SCIENCE LAB

157

MECH

157CLOBBY

158

STAIR

159

I.C.R.

161

CORR

164

I.C.R.

162

GIRL'S TLT

163

J.C.

165

BOY'S TLT

166

SPEC. ED.

167

I.C.R.

168

A4.2

E5

E3

A4.2C3

C5

159

151

160

163

165

157E

157A

167

161

168

162

153

154

152

145

140

141

142

148

147

156

166

A4.0E3

Sim

A4.0C3

Sim

A4.0E3

Sim

02

01

01

01

01

01

01

01

0101

0101

01

01

UP

UP

C.O.

139

149

150

157D

157C

164B

ELECTRICAL

150A

150A

INSTRUCTOR'S DESKCS# 6008A

TYP. GAS COCK -SEE SHEET A4.1

A4.3E1

A4.3

D1

157F

MTG. ROOM

158A

158A

IT CLST.

160

10

DN

INSTRUCTOR'S DESKCR# 6008A

ALL EXTERIOR ELEMENTS OF EXISTINGENTRY ( WALLS, CEILINGS ETC.) - PREP& PAINT.

P1P1

P1

P1

P1

P2

P1

158D

159A

143

146

157B

SEE SHEET A0.0 FOR ADD'LSIDEWALK / RAMP INFORMATION

TYP. STUDENT DESKCR# 6510

11

11

11 11

11

11

11

11

11

11

2

2

GENERAL RENOVATION NOTES:

1. SEE SHEET G1.6 FOR ADD'L INTERIOR PARTITION INFORMATION.

2. SEE SHEET LIFE SAFETY PLANS FOR FIRE RATED PARTITIONS.

3. ALL CMU CORES (NOT FILLED SOLID FOR REINFORCING) SHALL REC'VFOAMED-IN PLACE MASONRY INSULATION. SEE STRUCTURAL FORREINFORCING.

4. ALL WINDOWS ARE TO REC'V NEW WINDOW SHADES AS SPECIFIED. GC TOFIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING SHADES.

RENOVATION KEYNOTES:

01 INFILL EXISTING CMU WALL WHERE EXISTING DOORS & FRAME HAVE BEENREMOVED. INFILL TO MATCH SURROUNDING WALL TYPE AND PAINTED /FINISHED TO MATCH. MASONRY INFILL SHALL BE TOOTHED TOGETHER

02 THIS NOTE OMITTED.

03 ALIGN NEW WALL FLUSH w/ EXISTING WALL.

04 NEW CASED OPENING TO BE FINISHED TO MATCH THE SURROUNDINGCONDITIONS

05 NEW CONCRETE FLOOR SLAB AND FOOTINGS - SEE STRUCTURAL

06 INFILL OPENING IN EXISTING EXTERIOR WALL SYSTEM. MATCHSURROUNDING CONSTRUCTION. BRICK TO BE APPROVED BYARCHITECT PRIOR TO CONSTRUCTION

07 NEW CONCRETE PATIO SLAB - SEE STRUCTURAL

08 EXTERIOR BRICK TO BE CLEANED.

09 PROVIDE NEW STL. LINTEL - SEE STRUCTURAL

10 PROVIDE ATTIC ACCESS. WHERE POSSIBLE SAVE / RELOCATE EXISTINGACCESS LADDERS. SEE SHEET A4.4 FOR NEW LADDER DETAILS

11 PROVIDE MANUAL PROJECTION SCREENS AT THE TEACHING WALL OF EACHCLASSROOM (SEE SPECIFICATIONS)

1

WALL LEGEND:

EXISTING WALL SYSTEM

NEW WALL: 3 5/8" STL. STUDS WITH 5/8" GYP. BD. ON EACH FACE.

NON-RATED SMOKE PARTITION

1 HR RATED PARTITION

SEE SHEET G1.6 TYPICAL INTERIOR WALL PARTITIONS FOR ADD'L INFORMATION

HATCH INDICATESAREA OF NEW CONCRETESEE STRUCTURAL

INDICATES LOCATION OF GAS COCK - SEE SHEET A4.1

EXISTING EXTERIOR WALL

EXISTING CONCRETE SLAB

EXISTING PIPE HANDRAIL (PAINT)

EXISTING STEPS

EXISTING PIPE HANDRAIL (PAINT)

EXISTING CONCRETE SIDEWALK

EXISTING EXTERIOR WALL

1' -

0"

+/-

V.I.

F.

NEW CONCRETE TO PROVIDE5FT MIN. LANDING IN FRONT OFDOOR. FIELD VERIFY WIDTH

NEW CODE COMPLIANT PIPEHANDRAIL (PAINT)

5' -

0"

+/-

C2 / A1.8

11 / S2.1

SEE STRUCTURAL DETAIL 11 / S2.1FOR ADD'L INFORMATION

FIE

LD V

ER

IFY

HG

T.

FT

G.

SEE STRUCT.

EXISTING BLDG

COLD JOINT

EXISTING CONC.STOOP

NEW CONC. DOWELEDINTO EXISTING - SET INEPOXY

EXISTING PIPE HANDRAIL (PAINT)

NEW CODE COMPLIANT PIPEHANDRAIL (PAINT)

SEE STRUCTURAL DETAIL 11 / S2.1FOR ADD'L INFORMATION

GRADE

DATE:

PROJECTNUMBER:

DRAWING NUMBER:

SHEET TITLE:

REVISIONS:

PROJECT TITLE:

DRAWN BY:

NASHVILLE * DENVER * SAN ANTONIO

SAN FRANCISCO * PALM BEACH GARDEN

615.254.8500 * GHP1.com

217th FIFTH AVENUE NORTHNASHVILLE, TN. 37219

1

2

3

4

5

E D C B A

E D C B A

1

2

3

4

5

60 MUSIC SQUARE EASTSUITE 300

NASHVILLE, TN 37203PH: 615.383.6949

1162 FOSTER AVENUENASHVILLE, TN 37210

PH: 615.921.2200

A1.8

FIRST FLOOR AREA'B' RENOVATION

03.18.2016

13093.09

1252 FOSTER AVE,NASHVILLE, TN 37210

STEMPREPARATORYACADEMY

HIGH SCHOOLRENOVATION

C.D.

1/8" = 1'-0"D1 FIRST FLOOR - AREA 'B' RENOVATION

NORTH

1/4" = 1'-0"D2 DOOR STOOP EXPANSION 1/2" = 1'-0"C2 STOOP SECTION

1

1 REVISION #1 - 04.01.2016

2 REVISION #2 - 04.21.2016

Page 5: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

AreaOffice

FIRST LEVEL - KEY PLAN

AR

EA

'C'

RA

MP

UP

CORR.

128

CAFE

130

ELEC.

129

KITCHEN

134

STORAGE

132

TLT

133CORR.

139

DISHWASH

131

06

06

06

CAFE CORRIDOR

130A

130A

130B

A

A

A

A

A

NEW WINDOWS TO BECENTERED ON EXISTING WINDOWAS SHOWN, TYP. FIELD VERIFYCONDITIONS

NEW DOORS TO BE CENTERED ONEXISTING WINDOW OPENING ASSHOWN. FIELD VERIFY CONDITIONS

A2.0E4

01

01

07

A1

A2.0

E1

A2.0

E1

A3.0

C1

A2.0

08

08

C.O.

C.O.

C.O.

134A

128B

133

134C

139

10

01

129

PAINT EXISTING CASTIRON SINK

RELOCATE EXISTING HOSEBIBB - SEE PLUMBING

RETURN PASS THRU TO WORKINGORDER SEE SHEET A7.3 FOR ADD'LINFORMATION

P2

P2

P2

NEW CORRIDOR RAMP -SEE DETAIL E4 / A1.9

1' -

0"

MIN

.

LAN

DIN

GLA

ND

ING

LAN

DIN

GR

AM

P U

PR

AM

P U

P

EXISTING CORRIDOR RAMPTO REC'V NEW HANDRAILS

06

06

06

132

130C

SEE SHEET FS1 FOR ADD'LKITCHEN EQUIPMENT

SEE SHEET A0.0 FOR ADD'LSIDEWALK / RAMP INFORMATION

PROVIED COILING COUNTER DOOR ASSPECIFIED.

2

2

2

GENERAL RENOVATION NOTES:

1. SEE SHEET G1.6 FOR ADD'L INTERIOR PARTITION INFORMATION.

2. SEE SHEET LIFE SAFETY PLANS FOR FIRE RATED PARTITIONS.

3. ALL CMU CORES (NOT FILLED SOLID FOR REINFORCING) SHALL REC'VFOAMED-IN PLACE MASONRY INSULATION. SEE STRUCTURAL FORREINFORCING.

4. ALL WINDOWS ARE TO REC'V NEW WINDOW SHADES AS SPECIFIED. GC TOFIELD VERIFY WINDOW OPENINGS PRIOR TO ORDERING SHADES.

RENOVATION KEYNOTES:

01 INFILL EXISTING CMU WALL WHERE EXISTING DOORS & FRAME HAVE BEENREMOVED. INFILL TO MATCH SURROUNDING WALL TYPE AND PAINTED /FINISHED TO MATCH. MASONRY INFILL SHALL BE TOOTHED TOGETHER

02 THIS NOTE OMITTED.

03 ALIGN NEW WALL FLUSH w/ EXISTING WALL.

04 NEW CASED OPENING TO BE FINISHED TO MATCH THE SURROUNDINGCONDITIONS

05 NEW CONCRETE FLOOR SLAB AND FOOTINGS - SEE STRUCTURAL

06 INFILL OPENING IN EXISTING EXTERIOR WALL SYSTEM. MATCHSURROUNDING CONSTRUCTION. BRICK TO BE APPROVED BYARCHITECT PRIOR TO CONSTRUCTION

07 NEW CONCRETE PATIO SLAB - SEE STRUCTURAL

08 EXTERIOR BRICK TO BE CLEANED.

09 PROVIDE NEW STL. LINTEL - SEE STRUCTURAL

10 PROVIDE ATTIC ACCESS. WHERE POSSIBLE SAVE / RELOCATE EXISTINGACCESS LADDERS. SEE SHEET A4.4 FOR NEW LADDER DETAILS

11 PROVIDE MANUAL PROJECTION SCREENS AT THE TEACHING WALL OF EACHCLASSROOM (SEE SPECIFICATIONS)

1

WALL LEGEND:

EXISTING WALL SYSTEM

NEW WALL: 3 5/8" STL. STUDS WITH 5/8" GYP. BD. ON EACH FACE.

NON-RATED SMOKE PARTITION

1 HR RATED PARTITION

SEE SHEET G1.6 TYPICAL INTERIOR WALL PARTITIONS FOR ADD'L INFORMATION

HATCH INDICATESAREA OF NEW CONCRETESEE STRUCTURAL

INDICATES LOCATION OF GAS COCK - SEE SHEET A4.1

LANDING

6' - 0"

RAMP

20' - 7" +/-

LANDING

6' - 0"

RAMP

16' - 5" +/-

LANDING

5' - 0"

LENGTH OF CORRIDOR #139

53' - 11" +/-

1' -

5"

1' -

5"

1' - 0"

1' - 0"

HA

ND

RA

IL

34"

- 3

8"

HA

ND

RA

IL

34"

- 3

8"

10

' - 1

0" +

/-

2' -

10"

1 1/2" Ø HANDRAIL - FIRMLYATTACHED TO WALL

CJCJ

CJ

CJ CJ

CJ

4" CONCRETE RAMP / LANDINGTYP. - SEE STRUCTURAL

4" MIN. COMPACTEDGRAVEL FILL

DATE:

PROJECTNUMBER:

DRAWING NUMBER:

SHEET TITLE:

REVISIONS:

PROJECT TITLE:

DRAWN BY:

NASHVILLE * DENVER * SAN ANTONIO

SAN FRANCISCO * PALM BEACH GARDEN

615.254.8500 * GHP1.com

217th FIFTH AVENUE NORTHNASHVILLE, TN. 37219

1

2

3

4

5

E D C B A

E D C B A

1

2

3

4

5

60 MUSIC SQUARE EASTSUITE 300

NASHVILLE, TN 37203PH: 615.383.6949

1162 FOSTER AVENUENASHVILLE, TN 37210

PH: 615.921.2200

A1.9

FIRST FLOOR AREA'C' RENOVATION

03.18.2016

13093.09

1252 FOSTER AVE,NASHVILLE, TN 37210

STEMPREPARATORYACADEMY

HIGH SCHOOLRENOVATION

C.D.

1/8" = 1'-0"C1 FIRST FLOOR - AREA 'C' RENOVATION

NORTH

1/4" = 1'-0"E5 CORRIDOR #139

1 REVISION #1 - 04.01.2016

2 REVISION #2 - 04.21.2016

Page 6: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

GENERAL DOOR NOTES:

1. ALL 7' - 0" TALL DOORS TO RECEIVE (3) HINGES, TYP.

2. DOORS TALLER THAN 7' - 0" TO RECEIVE (4) OR MORE HINGES.

3. AT CENTER LINE OF DOOR, WHERE FLOOR MATERIAL CHANGESPROVIDE DOOR THRESHOLD OR TRANSITION STRIP. SUBMITRECOMMENDED TRANSITION MATERIAL FOR REVIEW & APPROVAL.

4. PROVIDE NEW ALUM. THRESHOLD AT ALL EXTERIOR DOORSUNLESS OTHERWISE NOTED.

5. THIS NOTE OMITTED.

6. PROVIDE NEW WEATHERSTRIPING @ ALL EXTERIOR DOORS.

7. PAINT EXTERIOR H.M. DOORS / FRAMES TO MATCH BRICK COLOR

8. SEE SPECIFICATIONS FOR DOOR FINISH. WOOD DOOR DESIGNATIONON THE DOOR SCHEDULE PERTAINS ONLY TO TYPE OF MATERIALNOT FINISH VENEER.

9. FIRE RATED DOORS REQUIRE EDGE SMOKE SEALING TO COMPLYWITH POSITIVE PRESSURE TEST.

10. FIRE RATED DOORS TO HAVE FIRE RATED FRAMES, HARDWARE,CLOSERS & ACCESSORIES TO MEET UL DESIGN. COORDINATEWITH SPECIFICATIONS.

11. THIS NOTE OMITTED.

12. ANY GLASS IN FIRE-RATED DOORS SHALL BE 1/4" WIRE GLASS

DOOR ABBREVIATIONS:

ALUM. ALUMINUM

HM HOLLOW METAL

F FLUSH

PR PAIR

TEMP'D 1/4" TEMPERED

WG 1/4" WIRE GLASS

WD WOOD

HG HALF GLASS

NV NARROW VIEW

EXIST. EXISTING

PL PLASTIC LAM.

PT PAINT

BL BORROWED LIGHT

FG FULL GLASS

ME MATCH EXISTING

DPS DOOR POSITION SWITCH

DATE:

PROJECTNUMBER:

DRAWING NUMBER:

SHEET TITLE:

REVISIONS:

PROJECT TITLE:

DRAWN BY:

NASHVILLE * DENVER * SAN ANTONIO

SAN FRANCISCO * PALM BEACH GARDEN

615.254.8500 * GHP1.com

217th FIFTH AVENUE NORTHNASHVILLE, TN. 37219

1

2

3

4

5

E D C B A

E D C B A

1

2

3

4

5

60 MUSIC SQUARE EASTSUITE 300

NASHVILLE, TN 37203PH: 615.383.6949

1162 FOSTER AVENUENASHVILLE, TN 37210

PH: 615.921.2200

A6.0

DOOR SCHEDULES

03.18.2016

13093.09

1252 FOSTER AVE,NASHVILLE, TN 37210

STEMPREPARATORYACADEMY

HIGH SCHOOLRENOVATION

C.D.

LOWER LEVEL DOOR SCHEDULE

MARK ROOM NAME

DOORDOORFRAME

FIRERTG HDW COMMENTSPAIR

DOOR SIZEMTL TYPE FINISH GLAZ MTL TYPEWIDTH HGT THK

001 STAIRS / VEST. - 3' - 0" 7' - 0" 1 3/4" - - - - - - 60 MIN 14.0 EXISTING DOOR / NEW HARDWARE002 CORRIDOR - 3' - 0" 7' - 0" 1 3/4" - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE003 MECH - 3' - 0" 7' - 0" 1 3/4" - - - - - - 45 MIN 15.0 EXISTING DOOR / NEW HARDWARE004 VESTIBULE - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 16.0005A COPY / WORK AREA - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 12.0005B OFC - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 2.0006 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0007 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0009 VESTIBULE - 3' - 0" 7' - 0" 1 3/4" - - - - - - 8.0 EXISTING DOOR / NEW HARDWARE010 MECH - 3' - 0" 7' - 0" 1 3/4" - - - - - - 45 MIN 8.0 EXISTING DOOR / NEW HARDWARE010A ELECTRICAL - 3' - 0" 7' - 0" 1 3/4" H.M. F PT - HM A 12.0011 J.C. - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 11.0012 TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0013 TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0014 CORRIDOR - 3' - 0" 7' - 0" 1 3/4" - - - - - - 13.0 EXISTING DOOR / NEW HARDWARE015 MEETING ROOM - 3' - 0" 7' - 0" 1 3/4" H.M. F PT - HM A 2.0016A CRAWL SPACE ACCESS - 3' - 0" 7' - 0" 1 3/4" - - - - - - 9.0 EXISTING DOOR / NEW HARDWARE016B CORRIDOR - 3' - 6" 7' - 0" 1 3/4" SCW F STAIN - HM A 60 MIN 10.0016C CORRIDOR - 3' - 0" 7' - 0" 1 3/4" - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE017 I.C.R. - 3' - 0" 7' - 0" 1 3/4" - - - - - - 5.0 EXISTING DOOR / NEW HARDWARE017A MECH - 3' - 0" 7' - 0" 1 3/4" - - - - - - 15.0 EXISTING DOOR / NEW HARDWARE018 TLT. - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0019 TLT. - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0020 WORK AREA - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 2.0021 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 6.0022 OFC. - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 2.0023 OFC. - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 2.0024A I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 6.0024B I.C.R. - 3' - 0" 7' - 0" 1 3/4" - - - - - - 1.0 EXISTING DOOR / NEW HARDWARE

FIRST FLOOR AREA 'A' - DOOR SCHEDULE

MARK ROOM NAME

DOORDOORFRAME

FIRERTG HDW COMMENTSPAIR

DOOR SIZEMTL TYPE FINISH GLAZ MTL TYPEWIDTH HGT THK

100 LOBBY - 3' - 0" 7' - 0" 1 3/4" - - - - - - - 4.0 EXISTING DOOR / REMOTE ACCESS, PROX READER, KEY FOB101A STAIRS - 3' - 0" 7' - 0" 1 3/4" - - - - - - 45 MIN 14.0 EXISTING DOOR / NEW HARDWARE101B STAIRS - 3' - 0" 7' - 0" 1 3/4" - - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE102 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0103 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0104 CORRIDOR - 3' - 0" 7' - 0" 1 3/4" - - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE105 GIRL'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 22.0106 J.C. - 2' - 8" 7' - 0" 1 3/4" HM F PT - HM A 17.0107 BOY'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 22.0108 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0109 SPEC. ED. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 6.0112A PROF. DEVELOPMENT - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 19.0112B PROF. DEVELOPMENT - 3' - 0" 7' - 0" 1 3/4" - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE112C PROF. DEVELOPMENT - 2' - 0" 7' - 0" 1 3/4" - - - - - - 18.0 EXISTING DOOR / NEW HARDWARE112D PROF. DEVELOPMENT YES 6' - 0" 7' - 0" 1 3/4" SCW FG STAIN 1/4 TEMP'D HM A 20.0113 ADMIN. / OFC. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 2.0113A MECH - 2' - 0" 7' - 0" 1 3/4" - - - - - - 18.0 EXISTING DOOR / NEW HARDWARE113B IT CLST - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 17.0114 TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0115 TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0117 MEETING - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 2.0118 WORK ROOM - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 2.0118A FILE ROOM - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 21.0119 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0120 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 6.0121 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0123 BOY'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 22.0124 J.C. - 2' - 8" 7' - 0" 1 3/4" HM F PT - HM A 17.0125 GIRL'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 22.0126 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0127 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0128A CORRIDOR - 3' - 0" 7' - 0" 1 3/4" - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE

1

1

1 REVISION #1 - 04.01.2016

2 REVISION #2 - 04.21.2016

2

2

Page 7: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

DOOR ABBREVIATIONS:

ALUM. ALUMINUM

HM HOLLOW METAL

F FLUSH

PR PAIR

TEMP'D 1/4" TEMPERED

WG 1/4" WIRE GLASS

WD WOOD

HG HALF GLASS

NV NARROW VIEW

EXIST. EXISTING

PL PLASTIC LAM.

PT PAINT

BL BORROWED LIGHT

FG FULL GLASS

ME MATCH EXISTING

DPS DOOR POSITION SWITCH

GENERAL DOOR NOTES:

1. ALL 7' - 0" TALL DOORS TO RECEIVE (3) HINGES, TYP.

2. DOORS TALLER THAN 7' - 0" TO RECEIVE (4) OR MORE HINGES.

3. AT CENTER LINE OF DOOR, WHERE FLOOR MATERIAL CHANGESPROVIDE DOOR THRESHOLD OR TRANSITION STRIP. SUBMITRECOMMENDED TRANSITION MATERIAL FOR REVIEW & APPROVAL.

4. PROVIDE NEW ALUM. THRESHOLD AT ALL EXTERIOR DOORSUNLESS OTHERWISE NOTED.

5. THIS NOTE OMITTED.

6. PROVIDE NEW WEATHERSTRIPING @ ALL EXTERIOR DOORS.

7. PAINT EXTERIOR H.M. DOORS / FRAMES TO MATCH BRICK COLOR

8. SEE SPECIFICATIONS FOR DOOR FINISH. WOOD DOOR DESIGNATIONON THE DOOR SCHEDULE PERTAINS ONLY TO TYPE OF MATERIALNOT FINISH VENEER.

9. FIRE RATED DOORS REQUIRE EDGE SMOKE SEALING TO COMPLYWITH POSITIVE PRESSURE TEST.

10. FIRE RATED DOORS TO HAVE FIRE RATED FRAMES, HARDWARE,CLOSERS & ACCESSORIES TO MEET UL DESIGN. COORDINATEWITH SPECIFICATIONS.

11. THIS NOTE OMITTED.

12. ANY GLASS IN FIRE-RATED DOORS SHALL BE 1/4" WIRE GLASS

EXISTING DOOR NOTE:

EXISTING DOORS & FRAMES THAT ARE TO BE REUSED SHALL BECLEANED AND REFINISHED AS SPECIFIED. ANY EXISTING DOOR THATIS LABELED AS FIRE-RATED ON THE NEW LIFE SAFETY DWGS. SHALLBE FIELD VERIFIED BY THE CONTRACTOR. IF IT DOES NOT CONFORMTO THE REQUIRED RATING THEN IT IS TO BE REPLACED WITH A NEWDOOR TO MATCH.

7' -

0"

3' - 0"

2"7'

- 0

"

2"

SCHEDULE

PER 2"

7' -

2"

7' -

0"

3' - 0"

6" 2' - 0" 6"

2' -

10

1/2"

6"

"F"FLUSH

"HG"HALF-GLASS

"A"

7' -

0"

3' - 0"

"F"PAIR OF FLUSH

6' - 0"

7' -

0"

6' - 0"

6" 2' - 0" 6"

2' -

10

1/2"

6"

"HG"PAIR OF HALF-GLASS

2"7'

- 0

"

2"

SCHEDULE

PER 2"

7' -

2"

"B"

7' -

0"

3' - 0"

6" 2' - 0" 6"

"HG2"HALF-GLASS

DATE:

PROJECTNUMBER:

DRAWING NUMBER:

SHEET TITLE:

REVISIONS:

PROJECT TITLE:

DRAWN BY:

NASHVILLE * DENVER * SAN ANTONIO

SAN FRANCISCO * PALM BEACH GARDEN

615.254.8500 * GHP1.com

217th FIFTH AVENUE NORTHNASHVILLE, TN. 37219

1

2

3

4

5

E D C B A

E D C B A

1

2

3

4

5

60 MUSIC SQUARE EASTSUITE 300

NASHVILLE, TN 37203PH: 615.383.6949

1162 FOSTER AVENUENASHVILLE, TN 37210

PH: 615.921.2200

A6.1

DOOR SCHEDULES

03.18.2016

13093.09

1252 FOSTER AVE,NASHVILLE, TN 37210

STEMPREPARATORYACADEMY

HIGH SCHOOLRENOVATION

C.D.

FIRST FLOOR AREA 'B' - DOOR SCHEDULE

MARK ROOM NAME

DOORDOORFRAME

FIRERTG HDW COMMENTSPAIR

DOOR SIZEMTL TYPE FINISH GLAZ MTL TYPEWIDTH HGT THK

139 CORRIDOR - 3' - 0" 7' - 0" 1 3/4" - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE140 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0141 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0142 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0143 GIRL'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 22.0145 J.C. - 3' - 0" 7' - 0" 1 3/4" HM F PT - HM A 17.0146 BOY'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 22.0147 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0148 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0149 MECH - 2' - 8" 7' - 0" 1 3/4" - - - - - - 45 MIN 8.0 EXISTING DOOR / NEW HARDWARE150 STG - 2' - 8" 7' - 0" 1 3/4" - - - - - - 45 MIN 8.0 EXISTING DOOR / NEW HARDWARE150A ELECTRICAL 3' - 0" 7' - 0" 1 3/4" HM F PT - HM A 12.0151 SPEC. ED. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0152 WORK AREA - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 2.0153 TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0154 TLT - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 7.0156 COMP. LAB. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0157A LAB. STG. - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 26.0157B MECH - 3' - 0" 7' - 0" 1 3/4" HM F PT - HM A 24.0157C MECH - 2' - 8" 7' - 0" 1 3/4" - - - - - - 18.0 EXISTING DOOR / NEW HARDWARE157D SCIENCE LAB - 3' - 0" 7' - 0" 1 3/4" - - - - - - 1.0 EXISTING DOOR / NEW HARDWARE157E SCIENCE LAB - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D WG HM A 45 MIN 5.0157F LAB STG - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 45 MIN 16.0158A MTG. ROOM 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM - 2.0158D LOBBY 3' - 6" 7' - 0" 1 3/4" FG F PT 1/4 TEMP'D HM - 23.0159 STAIRS - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D WG HM A 60 MIN 10.0159A STAIRS - 3' - 0" 7' - 0" 1 3/4" HM F PT - - - 3.0 NEW DOOR - EXISTING FRAME160 IT CLST - 3' - 0" 7' - 0" 1 3/4" HM F PT - HM A 45 MIN 25.0161 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 6.0162 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0163 GIRL'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW F PT - HM A 22.0164B CORRIDOR - 3' - 0" 7' - 0" 1 3/4" - - - - - - 3.0 EXISTING DOOR / NEW HARDWARE165 J.C. - 2' - 8" 7' - 0" 1 3/4" HM F PT - HM A 17.0 ADD DOOR CLOSER 281 P10 AS SPECIFIED166 BOY'S TLT - 3' - 0" 7' - 0" 1 3/4" SCW F PT - HM A 22.0167 SPEC. ED. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 6.0168 I.C.R. - 3' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM A 5.0

FIRST FLOOR AREA 'C' - DOOR SCHEDULE

MARK ROOM NAME

DOORDOORFRAME

FIRE RTG HDW COMMENTSPAIRDOOR SIZE

MTL TYPE FINISH GLAZ MTL TYPEWIDTH HGT THK128B CORRIDOR - 2' - 8" 7' - 0" 1 3/4" - - - - - - 30.0 EXISTING DOOR / NEW HARDWARE129 ELECTRICAL - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - HM A 45 MIN 29.0130A CAFE CORRIDOR YES 6' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D HM B 31.0130B CAFE CORRIDOR YES 6' - 0" 7' - 0" 1 3/4" SCW HG STAIN 1/4 TEMP'D WG HM B 45 MIN 28.0130C CAFE - 3' - 0" 7' - 0" 1 3/4" SCW FG2 STAIN 1/4 TEMP'D - - 3.0 NEW DOOR / EXISTING FRAME132 STORAGE - 3' - 0" 7' - 0" 1 3/4" SCW F STAIN - - - 17.0 NEW DOOR / EXISTING FRAME133 TLT - 2' - 8" 7' - 0" 1 3/4" - - - - - - 7.0 EXISTING DOOR / NEW HARDWARE134A KITCHEN - 2' - 8" 7' - 0" 1 3/4" - - - - - - 45 MIN 32.0 EXISTING DOOR / NEW HARDWARE134C KITCHEN - 3' - 6" 7' - 0" 1 3/4" - - - - - - 27.0 EXISTING DOOR / NEW HARDWARE

1/2" = 1'-0"E1 DOOR & FRAME ELEVATIONS

1

1

1 REVISION #1 - 04.01.2016

2

2

2

2

22

2

2 REVISION #2 - 04.21.2016

Page 8: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c
Page 9: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c
Page 10: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c
Page 11: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

COMcheck Software Version 4.0.2.0

Mechanical Compliance Certificate

Project Title:

2012 IECC

Project Type: Alteration

Location: Nashville, TennesseeClimate Zone: 4a

Construction Site:NASHVILLE, TN 37210

Owner/Agent: Designer/Contractor:PMCNASHVILLE, TN

Project Information

Energy Code:

STEM PREPARATORY ACADEMY

Mechanical Systems List

Quantity System Type & Description

Cooling: 1 each - Split System, Capacity = 95 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 11.20 EER, Required Efficiency = 11.20 EERFan System: FAN SYSTEM 3 | kITCHEN UNIT -- Compliance (Motor nameplate HP method) : Passes

Fans: FAN 3 Supply, Constant Volume, 3000 CFM, 0.5 motor nameplate hp

1 HVAC System (Single Zone):

Gas Instantaneous Water Heater, Capacity: 0 gallons, Input Rating: 199 Btu/h Proposed Efficiency: 0.90 EF, Required Efficiency: 0.67 EF

2 Water Heater 1:

Mechanical Compliance StatementCompliance Statement: The proposed mechanical alteration project represented in this document is consistent with the buildingplans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have beendesigned to meet the 2012 IECC requirements in COMcheck Version 4.0.2.0 and to comply with the mandatory requirementslisted in the Inspection Checklist.

Name - Title Signature Date

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:81 ofPage

rvandyke
Signature
rvandyke
Typewritten Text
Rich Van Dyke, P.E.
rvandyke
Typewritten Text
4/20/2016
Page 12: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

Inspection ChecklistRequirements: 100.0% were addressed directly in the COMcheck software

COMcheck Software Version 4.0.2.0

Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For eachrequirement, the user certifies that a code requirement will be met and how that is documented, or that an exceptionis being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.

Energy Code: 2012 IECC

Section#

& Req.IDPlan Review Complies? Comments/Assumptions

C103.2[PR2]1

Plans, specifications, and/orcalculations provide all informationwith which compliance can bedetermined for the mechanicalsystems and equipment anddocument where exceptions to thestandard are claimed. Loadcalculations per acceptableengineering standards andhandbooks.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C103.2[PR3]1

Plans, specifications, and/orcalculations provide all informationwith which compliance can bedetermined for the service waterheating systems and equipment anddocument where exceptions to thestandard are claimed. Hot watersystem sized per manufacturer'ssizing guide.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:82 ofPage

Page 13: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

Section#

& Req.IDFooting / Foundation Inspection Complies? Comments/Assumptions

C403.2.4.5[FO9]3

Freeze protection and snow/icemelting system sensors for futureconnection to controls.

CompliesDoes NotNot ObservableNot Applicable

Exception: Requirement does not apply.

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:83 ofPage

Page 14: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

Section#

& Req.IDMechanical Rough-In Inspection Complies? Comments/Assumptions

C403.2.3[ME55]2

HVAC equipment efficiency verified. CompliesDoes NotNot ObservableNot Applicable

See the Mechanical Systems list for values.

C403.2.5.1[ME59]1

Demand control ventilation providedfor spaces >500 sq.ft. and >25people/1000 sq.ft. occupant densityand served by systems with air sideeconomizer, auto modulating outsideair damper control, or design airflow>3,000 cfm.

CompliesDoes NotNot ObservableNot Applicable

Exception: Systems with energy recovery.

C403.2.7[ME60]2

HVAC ducts and plenums insulated.Where ducts or plenums are installedin or under a slab, verification mayneed to occur during FoundationInspection.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.8[ME61]2

HVAC piping insulation thickness.Where piping is installed in or under aslab, verification may need to occurduring Foundation Inspection.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.8.1[ME7]3

Piping Insulation exposed to weatheris protected from damage (due to sun,moisture, wind, etc.).

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.8[ME41]3

Thermally ineffective panel surfaces ofsensible heating panels haveinsulation >= R-3.5.

CompliesDoes NotNot ObservableNot Applicable

Exception: Requirement does not apply.

C403.2.7[ME10]2

Ducts and plenums sealed based onstatic pressure and location.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.7.1.3[ME11]3

Ductwork operating >3 in. watercolumn requires air leakage testing.

CompliesDoes NotNot ObservableNot Applicable

Exception: Requirement does not apply.

C403.3.1,C403.3.1.1[ME62]1

Air economizers provided whererequired, meet the requirements fordesign capacity, control signal,ventilation controls, high-limit shut-off,integrated economizer control, andprovide a means to relieve excessoutside air during operation.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.2.1[ME53]3

Air outlets and zone terminal deviceshave means for air balancing.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.4.2[ME66]2

VAV fan motors >=7.5 hp to be drivenby variable speed drive, have a vane-axial fan with variable pitch blades, orhave controls to limit fan motordemand.

CompliesDoes NotNot ObservableNot Applicable

Exception: Requirement does not apply.

C403.4.2[ME66]2

VAV fan motors >=7.5 hp to be drivenby variable speed drive, have a vane-axial fan with variable pitch blades, orhave controls to limit fan motordemand.

CompliesDoes NotNot ObservableNot Applicable

Exception: Requirement does not apply.

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:84 ofPage

Page 15: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

Section#

& Req.IDMechanical Rough-In Inspection Complies? Comments/Assumptions

C403.2.6[ME57]1

Exhaust air energy recovery onsystems meeting Table C403.2.6

CompliesDoes NotNot ObservableNot Applicable

C403.2.11[ME71]2

Unenclosed spaces that are heateduse only radiant heat.

CompliesDoes NotNot ObservableNot Applicable

Exception: Requirement does not apply.

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:85 ofPage

Page 16: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

Section#

& Req.IDFinal Inspection Complies? Comments/Assumptions

C403.2.4.1[FI47]3

Heating and cooling to each zone iscontrolled by a thermostat control.Minimum one humidity control deviceper installedhumidification/dehumidificationsystem.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.4.2[FI38]3

Thermostatic controls have a 5 °Fdeadband.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.4.2[FI20]3

Temperature controls have setpointoverlap restrictions.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.4.3[FI39]3

Each zone equipped with setbackcontrols using automatic time clock orprogrammable control system.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.4.3[FI40]3

Automatic Controls: Setback to 55°F(heat) and 85°F (cool); 7-day clock, 2-hour occupant override, 10-hourbackup

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C403.2.4.3.3[FI41]3

Systems include optimum startcontrols.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.5.1[FI7]3

Furnished HVAC as-built drawingssubmitted within 90 days of systemacceptance.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C303.3,C408.2.5.3[FI8]3

Furnished O&M manuals for HVACsystems within 90 days of systemacceptance.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.5.3[FI43]1

An air and/or hydronic systembalancing report is provided for HVACsystems.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.3.2[FI10]1

HVAC control systems have beentested to ensure proper operation,calibration and adjustment of controls.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C404.3[FI11]3

Public lavatory faucet watertemperature <=110°F.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C404.5[FI45]2

First 8 ft of outlet piping is insulated CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:86 ofPage

Page 17: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

Section#

& Req.IDFinal Inspection Complies? Comments/Assumptions

C403.2.2[FI27]3

HVAC systems and equipmentcapacity does not exceed calculatedloads.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.1[FI28]1

Commissioning plan developed byregistered design professional orapproved agency.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.4[FI29]1

Preliminary commissioning reportcompleted and certified by registereddesign professional or approvedagency.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.5.4[FI30]1

Final commissioning report due tobuilding owner within 90 days ofreceipt of certificate of occupancy.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.3.1[FI31]1

HVAC equipment has been tested toensure proper operation.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C408.2.3.3[FI32]1

Economizers have been tested toensure proper operation.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

C406[FI34]1

Efficient HVAC performance, efficientlighting system, or on-site supply ofrenewable energy consistent withwhat is shown the approved plans.

CompliesDoes NotNot ObservableNot Applicable

Requirement will be met.

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:87 ofPage

Page 18: G1 - Amazon S3 · g1.1 lower level - life safety plans x x g1.2 first floor - area 'a' life safety plan x g1.3 first floor - area 'b' life safety plan x g1.4 first floor - area 'c

Project Title:Data filename:

STEM PREPARATORY ACADEMYM:\2015 Job Numbers\15114 STEM High School\0-General\Basis of Design\COMCHECK\15114MECHANICAL.cck

04/21/16Report date:88 ofPage