g15s-0002-00

4
THE DOW CHEMICAL COMPANY ENGINEERING SPECIFICATION INSULATION G15S-0002-00 GLOBAL 03-APR-2006 Page 1 of 4 DOW RESTRICTED - For internal use only INSULATION CODES i --------------------- ZZ YY NZ -X | | || | | | || +------Jacket or Acoustical | | || Option | | || | | |+-----------Design Basis | | | | | +------------Thickness Table | | Regional Code | | | | | +------------------Insulation material | | +------------------------Temperature range EXAMPLES: C=08MW1E-M C=08MW1A-1 Temperature Range ----------------- Code Degrees F Degrees C ---- --------- --------- SP Special (See Note 4) 16 1601 to 1700 871 to 927 15 1500 to 1599 816 to 870 14 1400 to 1499 760 to 815 13 1300 to 1399 705 to 759 12 1200 to 1299 650 to 704 11 1100 to 1199 593 to 649 10 1000 to 1099 538 to 592 09 900 to 999 482 to 537 08 800 to 899 427 to 481 07 700 to 799 371 to 426 06 600 to 699 316 to 370 05 500 to 599 260 to 315 04 400 to 499 204 to 259 03 300 to 399 149 to 203 02 200 to 299 93 to 148 01 100 to 199 38 to 92 00 ii 81 to 99 28 to 37

Upload: shah-alam

Post on 16-Feb-2016

376 views

Category:

Documents


3 download

DESCRIPTION

G15S-0002-00

TRANSCRIPT

Page 1: G15S-0002-00

THE DOW CHEMICAL COMPANY ENGINEERING SPECIFICATION INSULATION G15S-0002-00 GLOBAL 03-APR-2006

Page 1 of 4

DOW RESTRI CTED - For i nt er nal use onl y

INSULATION CODESi - - - - - - - - - - - - - - - - - - - - -

ZZ YY NZ - X | | | | | | | | | +- - - - - - Jacket or Acoust i cal | | | | Opt i on | | | | | | | +- - - - - - - - - - - Desi gn Basi s | | | | | +- - - - - - - - - - - - Thi ckness Tabl e | | Regi onal Code | | | | | +- - - - - - - - - - - - - - - - - - I nsul at i on mat er i al | | +- - - - - - - - - - - - - - - - - - - - - - - - Temper at ur e r ange EXAMPLES: C=08MW1E- M C=08MW1A- 1 Temperature Range - - - - - - - - - - - - - - - - - Code Degr ees F Degr ees C - - - - - - - - - - - - - - - - - - - - - - SP Speci al ( See Not e 4) 16 1601 t o 1700 871 t o 927 15 1500 t o 1599 816 t o 870 14 1400 t o 1499 760 t o 815 13 1300 t o 1399 705 t o 759 12 1200 t o 1299 650 t o 704 11 1100 t o 1199 593 t o 649 10 1000 t o 1099 538 t o 592 09 900 t o 999 482 t o 537 08 800 t o 899 427 t o 481 07 700 t o 799 371 t o 426 06 600 t o 699 316 t o 370 05 500 t o 599 260 t o 315 04 400 t o 499 204 t o 259 03 300 t o 399 149 t o 203 02 200 t o 299 93 t o 148 01 100 t o 199 38 t o 92 00 i i 81 t o 99 28 t o 37

Page 2: G15S-0002-00

THE DOW CHEMICAL COMPANY ENGINEERING SPECIFICATION INSULATION G15S-0002-00 GLOBAL 03-APR-2006

Page 2 of 4

DOW RESTRI CTED - For i nt er nal use onl y

Temperature Ranges Code Degr ees F Degr ees C - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 50 80 t o 61 27 t o 17 51 60 t o 46 16 t o 8 52 45 t o 31 7 t o 0 53 30 t o 16 - 1 t o - 8 54 15 t o 1 - 9 t o - 17 55 0 t o - 24 - 18 t o - 31 56 - 25 t o - 49 - 32 t o - 45 57 - 50 t o - 74 - 46 t o - 58 58 - 75 t o - 99 - 59 t o - 72 59 - 100 t o - 149 - 73 t o - 100 60 - 150 t o - 199 - 101 t o - 128 61 - 200 t o - 249 - 129 t o - 156 62 - 250 t o - 300 - 157 t o - 184

Insulation Material - - - - - - - - - - - - - - - - - - - - - - -

Dow Engineering Specification Code Material - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - G15S- 1001- 00 PI Pol y i socyanur at e G15S- 1001- 01 I F I nj ect ed pol y i socyanur at e c/ w Al umi num j acket G15S- 1001- 02 I F I nj ect ed pol y i socyanur at e c/ w st ai nl ess j acket G15S- 1002- 00 MW Mi ner al Wool G15S- 1003- 00 CS Cal c i um Si l i cat e G15S- 1004- 00 CG Cel l ul ar Gl ass G15S- 1004- 01 CG Cel l ul ar Gl ass, ( mandat or y 2 l ayer s) G15S- 1004- 02 SF St r at aFab, ( cel l ul ar gl ass) G15S- 1004- 03 CG Cel l ul ar Gl ass G15S- 1005- 00 PR Per l i t e G15S- 1006- 00 ST Pol yst yr ene G15S- 1020- 00 DA Dual : Cer ami c Fi ber / Mi n. Wool G15S- 2001- 00 PI Pol y i socyanur at e G15S- 2001- 01 I F I nj ect ed pol y i socyanur at e c/ w al umi num j acket G15S- 2001- 02 I F I nj ect ed pol y i socyanur at e c/ w st ai nl ess j acket G15S- 2002- 00 ST Pol yst yr ene G15S- 2003- 00 CG Cel l ul ar Gl ass G15S- 2003- 01 CG Cel l ul ar Gl ass, ( mandat or y 2 l ayer s) G15S- 2010- 01 CG Cel l ul ar Gl ass, ( mandat or y 2 l ayer s) G15S- 2010- 02 CG St r at Fab, ( cel l ul ar gl ass) G15S- 2010- 03 CG Cel l ul ar Gl ass G15S- 2020- 00 DB Dual : Pol y i socyanur at e/ Cel l ul ar Gl ass G15S- 3001- 00 FR Fl exi bl e Removabl e Reusabl e G15S- 3002- 00 SS St andi ng Seam Tank Syst em G15S- 1002- 00 MC Mi ner al wool wi t h Cel l ul ar Gl ass G15S- 1004- 00 over f l anges G15S- 4002- 10 PS Pr ot ect i ve Heat Shi el d, no i nsul at i on

Page 3: G15S-0002-00

THE DOW CHEMICAL COMPANY ENGINEERING SPECIFICATION INSULATION G15S-0002-00 GLOBAL 03-APR-2006

Page 3 of 4

DOW RESTRI CTED - For i nt er nal use onl y

Thickness Table Regional Code - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 = Nor t h Amer i ca - Al l Regi ons 2 = Eur ope Design Basisiii - - - - - - - - - - - - A = Acoust i cal Laggi ng C = Col d I nsul at i on D = Cycl i c ser v i ce, busi ness def i ned f i r e pr ot ect i on not r equi r ed E = Ener gy Conser vat i on – Hot F = Fi r e Pr ot ect i on, non –cycl i c ser v i ce

f = f i r e Pr ot ect i on, cycl i c ser v i ce

P = Per sonnel Pr ot ect i on PS = Pr ot ect i ve Heat Shi el d, per sonnel pr ot ect i on

R = Rapi d Temper at ur e Change ( i nsul at i on t emper at ur e i ncr eases >2° C per mi nut e)

Not e: Cycl i c ser v i ce exi st s i f t he oper at i ng t emper at ur e

cycl es bet ween t he hot and col d i nsul at i on c l asses.

Page 4: G15S-0002-00

THE DOW CHEMICAL COMPANY ENGINEERING SPECIFICATION INSULATION G15S-0002-00 GLOBAL 03-APR-2006

Page 4 of 4

DOW RESTRI CTED - For i nt er nal use onl y

Jacket Code or Acoustical Option - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Dow Engi neer i ng Speci f i cat i on Code* Mat er i al - - - - - - - - - - - - - - - - - - - - - - - - - - - G15S- 4001- 00 - M Met al - Al umi num G15S- 4002- 00 - S St ai nl ess St eel G15S- 4002- 10 - S St ai nl ess St eel , pr ot ect i ve shi el d G15S- 4003- 00 - V PVC/ CPVC G15S- 4004- 00 - R FRP/ GRP G15S- 4006- 00 - L Fi el d Appl i ed Lami nat e G15S- 4007- 00 - T Tedl ar Coat ed Al umi num Not e 3 - 1 Acoust i c Opt i on 1 Not e 3 - 2 Acoust i c Opt i on 2 Not e 3 - n Acoust i c Opt i on n * I ncl ude dash( - ) when ent er i ng t hi s code. NOTES: 1) For use wi t h Dow Engi neer i ng Speci f i cat i on G15S- 0001- 50. 2) Codes t o be used on P&I D' s, Pi pi ng Li ne Schedul es, Equi pment Schedul es, i somet r i c dr awi ngs, et c. 3) See Job Speci f i cat i on f or def i ni t i on of t he var i ous Acoust i c Opt i ons, or f or a r ef er ence t o a speci f i cat i on. 4) Use Code SP f or sel ect i ng a t hi ckness di f f er ent f r om t hose l i s t ed i n t he Tabl es. Add Mat er i al Code and t hi ckness, XXXm ( mi l l i met er s) , or XXXi ( i nches) . See exampl es bel ow. I f f ur t her i nf or mat i on i s r equi r ed, see Job Speci f i cat i on. C=SPCG2. 5i C=SPMW200m i 4/ 3/ 06, MOC 2006- 3682, By: Danny Fr ey, Super cedes I ssue Dat e: 23- Mar - 2006, Updat es t hr oughout due t o new EMETL speci f i cat i ons. i i 4/ 7/ 04, MOC 2004- 1817, By: Danny Fr ey, Super cedes I ssue Dat e: 15- Jun- 1998, Added Code “ 00” t o Page 1. i i i 12/ 13/ 04, MOC 2004- 2433, By: Danny Fr ey, Super cedes I ssue Dat e: 10- Nov-2004, Updat ed t he Desi gn Basi s, changed Fi r e Pr oof i ng t o Fi r e Pr ot ect i on, added Fi r e Pr ot ect i on f or cycl i c ser v i ce, added det ai l s f or Rapi d Temper at ur e Change and del et ed SF = St r at aFab.