  • IBM System Networking RackSwitch G8264

    Installation Guide

  • IBM System Networking RackSwitch G8264

    Installation Guide

  • Note: Before using this information and the product it supports, read the Warranty Information document, the general information inAppendix B, Notices, on page 67, and the Important Notices document that comes with the product. Read the IBM System SafetyNotices and the License Agreement for Machine Code (LAMC) document on the IBM Documentation CD. Read the EnvironmentalNotices and User Guide on the IBM Environmental Notices CD.

    Fourth Edition (January 2014) Copyright IBM Corporation 2014.US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contractwith IBM Corp.

  • SafetyBefore installing this product, read the Safety Information.

    Antes de instalar este produto, leia as Informaes de Segurana.

    Pred instalac tohoto produktu si prectete prrucku bezpecnostnch instrukc.

    Ls sikkerhedsforskrifterne, fr du installerer dette produkt.

    Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.

    Ennen kuin asennat tmn tuotteen, lue turvaohjeet kohdasta Safety Information.

    Avant d'installer ce produit, lisez les consignes de scurit.

    Vor der Installation dieses Produkts die Sicherheitshinweise lesen.

    Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.

    Les sikkerhetsinformasjonen (Safety Information) fr du installerer dette produktet.

    Antes de instalar este produto, leia as Informaes sobre Segurana.

    Antes de instalar este producto, lea la informacin de seguridad.

    Copyright IBM Corp. 2014 iii

  • Ls skerhetsinformationen innan du installerar den hr produkten.

    Bu rn kurmadan nce gvenlik bilgilerini okuyun.

    Important:

    Each caution and danger statement in this document is labeled with anumber. This number is used to cross reference an English-languagecaution or danger statement with translated versions of the caution ordanger statement in the Systems Safety Notices document.

    For example, if a caution statement is labeled D005, translations forthat caution statement are in the Systems Safety Notices documentunder D005.

    Be sure to read all caution and danger statements in this documentbefore you perform the procedures. Read any additional safetyinformation that comes with the switch or optional device before youinstall the device.

    DANGERHazardous voltage, current, or energy levels are present inside anycomponent that has this label attached. Do not open any cover or barrierthat contains this label.

    (L001)

    iv IBM RackSwitch G8264: Installation Guide

  • DANGERRack-mounted devices are not to be used as shelves or work spaces.

    (L002)

    Safety v

  • DANGERMultiple power cords. The product might be equipped with multiple powercords. To remove all hazardous voltages, disconnect all power cords.

    (L003)1 2

    or

    !

    1

    2

    DANGER

    An electrical outlet that is not correctly wired could place hazardousvoltage on the metal parts of the system or the devices that attach to thesystem. It is the responsibility of the customer to ensure that the outlet iscorrectly wired and grounded to prevent an electrical shock. (D004)

    vi IBM RackSwitch G8264: Installation Guide

  • Safety vii

  • DANGER

    When working on or around the system, observe the following precautions:

    Electrical voltage and current from power, telephone, and communicationcables are hazardous. To avoid a shock hazard:v Connect power to this unit only with the IBM provided power cord. Do

    not use the IBM provided power cord for any other product.v Do not open or service any power supply assembly.v Do not connect or disconnect any cables or perform installation,

    maintenance, or reconfiguration of this product during an electricalstorm.

    v The product might be equipped with multiple power cords. To remove allhazardous voltages, disconnect all power cords.

    v Connect all power cords to a properly wired and grounded electricaloutlet. Ensure that the outlet supplies proper voltage and phase rotationaccording to the system rating plate.

    v Connect any equipment that will be attached to this product to properlywired outlets.

    v When possible, use one hand only to connect or disconnect signalcables.

    v Never turn on any equipment when there is evidence of fire, water, orstructural damage.

    v Disconnect the attached power cords, telecommunications systems,networks, and modems before you open the device covers, unlessinstructed otherwise in the installation and configuration procedures.

    v Connect and disconnect cables as described in the following procedureswhen installing, moving, or opening covers on this product or attacheddevices.To disconnect:1. Turn off everything (unless instructed otherwise).2. Remove the power cords from the outlets.3. Remove the signal cables from the connectors.4. Remove all cables from the devices.To connect:1. Turn off everything (unless instructed otherwise).2. Attach all cables to the devices.3. Attach the signal cables to the connectors.4. Attach the power cords to the outlets.5. Turn on the devices.

    v Sharp edges, corners and joints may be present in and around thesystem. Use care when handling equipment to avoid cuts, scrapes andpinching.

    (D005)

    viii IBM RackSwitch G8264: Installation Guide

  • CAUTION:This product might contain one or more of the following devices: CD-ROMdrive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1laser products. Note the following information:v Do not remove the covers. Removing the covers of the laser product could

    result in exposure to hazardous laser radiation. There are no serviceableparts inside the device.

    v Use of the controls or adjustments or performance of procedures otherthan those specified herein might result in hazardous radiation exposure.

    (C026)

    CAUTION:Data processing environments can contain equipment transmitting on systemlinks with laser modules that operate at greater than Class 1 power levels. Forthis reason, never look into the end of an optical fiber cable or openreceptacle. (C027)

    CAUTION:This product contains a Class 1M laser. Do not view directly with opticalinstruments. (C028)

    Safety ix

  • DANGER

    Observe the following precautions when working on or around your IT racksystem:v Heavy equipmentpersonal injury or equipment damage might result if

    mishandled.v Always lower the leveling pads on the rack cabinet.v Always install stabilizer brackets on the rack cabinet.v To avoid hazardous conditions due to uneven mechanical loading,

    always install the heaviest devices in the bottom of the rack cabinet.Always install servers and optional devices starting from the bottom ofthe rack cabinet.

    v Rack-mounted devices are not to be used as shelves or work spaces. Donot place objects on top of rack-mounted devices.

    v Each rack cabinet might have more than one power cord. Be sure todisconnect all power cords in the rack cabinet when directed todisconnect power during servicing.

    v Connect all devices installed in a rack cabinet to power devices installedin the same rack cabinet. Do not plug a power cord from a deviceinstalled in one rack cabinet into a power device installed in a differentrack cabinet.

    v An electrical outlet that is not correctly wired could place hazardousvoltage on the metal parts of the system or the devices that attach to thesystem. It is the responsibility of the customer to ensure that the outletis correctly wired and grounded to prevent an electrical shock.

    (R001 part 1 of 2)

    x IBM RackSwitch G8264: Installation Guide

  • CAUTION:v Do not install a unit in a rack where the internal rack ambient temperatures

    will exceed the manufacturers recommended ambient temperature for allyour rack-mounted devices.

    v Do not install a unit in a rack where the air flow is compromised. Ensurethat air flow is not blocked or reduced on any side, front, or back of a unitused for air flow through the unit.

    v Consideration should be given to the connection of the equipment to thesupply circuit so that overloading of the circuits does not compromise thesupply wiring or overcurrent protection. To provide the correct powerconnection to a rack, refer to the rating labels located on the equipment inthe rack to determine the total power requirement of the supply circuit.

    v (For sliding drawers) Do not pull out or install any drawer or feature if therack stabilizer brackets are not attached to the rack. Do not pull out morethan one drawer at a time. The rack might become unstable if you pull outmore than one drawer at a time.

    v (For fixed drawers) This drawer is a fixed drawer and must not be movedfor servicing unless specified by the manufacturer. Attempting to move thedrawer partially or completely out of the rack might cause the rack tobecome unstable or cause the drawer to fall out of the rack.

    (R001 part 2 of 2)

    Important:

    This product is also designed for IT power distribution systems withphase-to-phase voltage of 230V.

    Important:

    Machinenlrminformations-Verordnung - 3. GPSGV, der hchsteShalldruckpegel betrgt 70 dB (A) oder weniger.

    Safety xi

  • xii IBM RackSwitch G8264: Installation Guide

  • ContentsSafety . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii

    Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . 1The IBM Documentation CD . . . . . . . . . . . . . . . . . . . . 1

    Hardware and software requirements . . . . . . . . . . . . . . . . 2Related documentation . . . . . . . . . . . . . . . . . . . . . . 2Notices and statements in this document . . . . . . . . . . . . . . . . 2RackSwitch G8264 features . . . . . . . . . . . . . . . . . . . . 3Major components . . . . . . . . . . . . . . . . . . . . . . . . 4

    Hardware options . . . . . . . . . . . . . . . . . . . . . . . 4Switch unit . . . . . . . . . . . . . . . . . . . . . . . . . . 4Switch ports . . . . . . . . . . . . . . . . . . . . . . . . . 6Switch LEDs . . . . . . . . . . . . . . . . . . . . . . . . . 10

    Technical specifications . . . . . . . . . . . . . . . . . . . . . . 12Physical characteristics . . . . . . . . . . . . . . . . . . . . . 12Environmental specifications . . . . . . . . . . . . . . . . . . . 12Power specifications . . . . . . . . . . . . . . . . . . . . . . 12

    Chapter 2. Installing the RackSwitch and options . . . . . . . . . . . 15Before installing the RackSwitch . . . . . . . . . . . . . . . . . . 15Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 16Package contents . . . . . . . . . . . . . . . . . . . . . . . . 16Environmental requirements . . . . . . . . . . . . . . . . . . . . 17

    Preventing electric shock . . . . . . . . . . . . . . . . . . . . 17Handling static-sensitive devices . . . . . . . . . . . . . . . . . 19

    Installing the RackSwitch in the standard equipment rack . . . . . . . . . 20Installing the RackSwitch in the IBM iDataPlex rack . . . . . . . . . . . 22Installing the RackSwitch in an IBM System x or Power rack . . . . . . . . 24Installing the 1U air duct option . . . . . . . . . . . . . . . . . . . 28

    Mounting kit components . . . . . . . . . . . . . . . . . . . . 28Installing an SFP, SFP+, and QSFP+ transceiver . . . . . . . . . . . . 32

    Installing an SFP copper transceiver . . . . . . . . . . . . . . . . 32Installing an SFP optical transceiver . . . . . . . . . . . . . . . . 32Installing an SFP+ optical transceiver . . . . . . . . . . . . . . . 33Installing a QSFP+ optical transceiver . . . . . . . . . . . . . . . 34

    Chapter 3. Removing and replacing the RackSwitch and components . . . 37Removing and replacing the RackSwitch chassis unit from a rack . . . . . . 37

    Removing the RackSwitch chassis from a standard equipment rack . . . . 37Removing the RackSwitch chassis from a System x or Power rack. . . . . 39Removing the RackSwitch chassis from an iDataPlex rack . . . . . . . . 41

    Removing and replacing the power supply module . . . . . . . . . . . . 42Removing the AC power supply module. . . . . . . . . . . . . . . 43Replacing the AC power supply module . . . . . . . . . . . . . . . 43

    Removing and replacing the fan module . . . . . . . . . . . . . . . 44Removing the fan module . . . . . . . . . . . . . . . . . . . . 44Replacing the fan module . . . . . . . . . . . . . . . . . . . . 45

    Removing the 1U air duct option . . . . . . . . . . . . . . . . . . 45Removing and replacing the main RackSwitch chassis unit . . . . . . . . 46Configuring Vital Product Data after a switch replacement . . . . . . . . . 46

    Chapter 4. Initializing the RackSwitch . . . . . . . . . . . . . . . 49Default configuration . . . . . . . . . . . . . . . . . . . . . . . 50

    Copyright IBM Corp. 2014 xiii

  • Configuring an IP interface . . . . . . . . . . . . . . . . . . . . 51Updating firmware. . . . . . . . . . . . . . . . . . . . . . . . 52Using the Boot Management menu . . . . . . . . . . . . . . . . . 52

    Chapter 5. Troubleshooting. . . . . . . . . . . . . . . . . . . . 55System LED is not lit. . . . . . . . . . . . . . . . . . . . . . . 55Port link LED is not lit . . . . . . . . . . . . . . . . . . . . . . 55Temperature sensor warning . . . . . . . . . . . . . . . . . . . . 55Switch does not initialize (boot) . . . . . . . . . . . . . . . . . . . 55

    Chapter 6. Replaceable switch parts . . . . . . . . . . . . . . . . 57

    Appendix A. Getting help and technical assistance . . . . . . . . . . 65Before you call . . . . . . . . . . . . . . . . . . . . . . . . . 65Opening a support request . . . . . . . . . . . . . . . . . . . . 65How to send Dynamic System Analysis data to IBM . . . . . . . . . . . 66Using the documentation . . . . . . . . . . . . . . . . . . . . . 66Getting help and information from the World Wide Web . . . . . . . . . . 66Creating a personalized support web page. . . . . . . . . . . . . . . 66

    Appendix B. Notices . . . . . . . . . . . . . . . . . . . . . . 67Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . 67Important notes. . . . . . . . . . . . . . . . . . . . . . . . . 68Particulate contamination . . . . . . . . . . . . . . . . . . . . . 69Documentation format . . . . . . . . . . . . . . . . . . . . . . 69Telecommunication regulatory statement . . . . . . . . . . . . . . . 70Electronic emission notices . . . . . . . . . . . . . . . . . . . . 70

    Federal Communications Commission (FCC) statement . . . . . . . . . 70Industry Canada Class A emission compliance statement . . . . . . . . 70Avis de conformit la rglementation d'Industrie Canada . . . . . . . . 70Australia and New Zealand Class A statement . . . . . . . . . . . . 71European Union EMC Directive conformance statement . . . . . . . . . 71Germany Class A statement . . . . . . . . . . . . . . . . . . . 71VCCI Class A statement . . . . . . . . . . . . . . . . . . . . 72Japan Electronics and Information Technology Industries Association (JEITA)

    statement . . . . . . . . . . . . . . . . . . . . . . . . . 72Korea Communications Commission (KCC) statement . . . . . . . . . 73Russia Electromagnetic Interference (EMI) Class A statement. . . . . . . 73People's Republic of China Class A electronic emission statement . . . . . 73Taiwan Class A compliance statement . . . . . . . . . . . . . . . 73

    Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

    xiv IBM RackSwitch G8264: Installation Guide

  • Chapter 1. IntroductionThis Installation Guide provides information and instructions for installing andremoving an IBM System Networking RackSwitch G8264. For information aboutconfiguration and management of the switch, see the Command Reference and theproduct release notes.

    The RackSwitch G8264 is a rackable aggregation switch with unmatched line-rateLayer 2 and Layer 3 performance. The RackSwitch G8264 uses a wire-speed,non-blocking switching fabric that provides simultaneous wire-speed transport ofmultiple packets at low latency on all ports.

    The RackSwitch G8264 contains forty-eight 10 GbE Small-Form-Pluggable Plus(SFP+) ports and four 40 GbE Quad Small-Form-Pluggable Plus (QSFP+) ports.The switch also supports legacy 1 GbE connections. The SFP+ ports can bepopulated with optical or copper transceivers, or Direct Attach Cables (DACs). TheQSFP+ ports can be populated with optical QSFP+ transceivers or DACs.

    This 1U switch is rack mountable in either the horizontal or vertical direction,depending on your application.

    You can manage the switch through the console port, or through a networkconnection using Telnet, a Web browser-based interface, or SNMP-based networkmanagement software. For more information, see Chapter 4, Initializing theRackSwitch, on page 49.

    If documentation updates are available, you can download them fromhttp://www.ibm.com/supportportal/. The switch might have features that are notdescribed in the documentation that comes with the switch, and the documentationmight be updated occasionally to include information about those features, ortechnical updates might be available to provide additional information that is notincluded in the switch documentation.

    To check for documentation updates,1. Go to http://www.ibm.com/supportportal/and click Documentation.2. In the Quick find field enter the name of your product and press Enter.

    Note: Changes are made periodically to the IBM website. Procedures for locatingfirmware and documentation might vary slightly from what is described in thisdocument.

    The IBM Documentation CDThe IBM Documentation CD contains documentation for your switch in PortableDocument Format (PDF).

    The Documentation CD includes the product installation guide, safety document andthe license machine access code document. The Environmental Notices CDincludes the Environmental Notices for the product. To access these documents:v If you are using a Windows operating system, insert the CD into the CD or DVD

    drive and from My Computer, double click the CD or DVD drive and select theinstallation guide that supports your product.

    Copyright IBM Corp. 2014 1

  • v If you are using a Linux operating system, insert the CD into the CD or DVDdrive and run the following command from the mnt/cd directory, sh.linux.sh.Select the installation guide that supports your product.

    Double click the Installation Guides directory and select the installation guide thatsupports your product.

    Hardware and software requirementsThe IBM Documentation CD requires the following minimum hardware andsoftware:v Microsoft Windows NT 4.0 (with Service Pack 3 or later), Windows 2000, or Red

    Hat Linuxv 100 MHz microprocessorv 32 MB of RAMv Adobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating

    systems

    Related documentationThe following related documentation is available at http://www.ibm.com/systems/support/:v IBM System Networking RackSwitch G8264 Application Guidev IBM System Networking RackSwitch G8264 Menu-based Command Referencev IBM System Networking RackSwitch G8264 ISCLIIndustry Standard CLI

    Command Referencev IBM System Networking RackSwitch G8264 BBI Quick Guide

    Notices and statements in this documentThe caution and danger statements in this document are also in the multilingualSafety Information document, which is on the IBM Documentation CD. Eachstatement is numbered for reference to the corresponding statement in the SafetyInformation document.

    The following notices and statements are used in this document:v Note: These notices provide important tips, guidance, or advice.v Important: These notices provide information or advice that might help you avoid

    inconvenient or problem situations.v Attention: These notices indicate potential damage to programs, devices, or

    data. An attention notice is placed just before the instruction or situation in whichdamage could occur.

    v Caution: These statements indicate situations that can be potentially hazardousto you. A caution statement is placed just before the description of a potentiallyhazardous procedure step or situation.

    v Danger: These statements indicate situations that can be potentially lethal orextremely hazardous to you. A danger statement is placed just before thedescription of a potentially lethal or extremely hazardous procedure step orsituation.

    2 IBM RackSwitch G8264: Installation Guide

  • RackSwitch G8264 featuresThis section provides an overview of RackSwitch G8264 features.

    Performancev 1280 Gbps throughput (full duplex), non-blocking switching architecturev 100% line ratev Deterministic port-to-port latency under 2 microseconds with 64 B packets

    Management Featuresv Clients

    Industry standard command-line interface (ISCLI) Browser-based Interface (BBI) System Networking Switch Center

    v Protocols SNMP v1, v2, v3 Remote Monitoring (RMON) Network Time Protocol (NTP) support DHCP

    v Software upgrades Dual software images Upgrade via serial, browser, or TFTP

    Software Featuresv Security

    Secure interface login and password RADIUS and TACACS+ SSHv2 HTTPS Secure Browser-based interface Wire-speed filtering with Access Control Lists (ACLs)

    v Layer 2 2048 VLANs (802.1Q), including Private VLANs Multi-link trunking, compatible with Cisco EtherChannel LACP (IEEE 802.3ad) Spanning Tree (802.1D), Multiple Spanning Tree (802.1s), Multiple Spanning Tree (802.1s), Rapid Spanning

    Tree (802.1w), with Fast Uplink Convergence 32 K forwarding database entries

    v Layer 3 Dynamic routing

    - RIP v1, v2- OSPF- BGP

    128 configurable interfaces (static or DHCP) DHCP Relay IP forwarding IGMP Snooping v1, v2, v3

    Chapter 1. Introduction 3

  • 8 K ARP entries IPv6 host management

    v Quality of service 802.1p priority queues Differentiated Services Code Point (DSCP) support

    v Availability Layer 2 failover Hot links VRRP

    Major componentsThis section describes the RackSwitch G8264 hardware components.

    Hardware optionsThe following list provides an overview of G8264 hardware:v Switch unitv Mounting hardware

    Standard 2-post rack mounting brackets and screws IBM iDataPlex rack mounting brackets and screws (purchased separately) IBM System Networking adjustable 19 4-post rail mounting brackets and

    screws (for Power and System x racks that must be purchased separately)v Hot-swap power supply (2)v Hot-swap fans (up to 4)

    Switch unitThe switch unit is a 1U rack-mountable Gigabit Ethernet switch. You can mount it ineither the horizontal or vertical direction.

    The switch allows for flexible mounting, as follows:v RackSwitch G8264 (front-to-rear) provides front-to-rear airflow.v RackSwitch G8264 (rear-to-front) provides rear-to-front airflow.PortsThe switch unit contains the following ports:v Forty-eight 10GbE SFP+ portsv Four QSFP+ portsv One RJ-45 management portv One RS-232 serial console portv One USB port for mass storage

    4 IBM RackSwitch G8264: Installation Guide

  • The following illustrations show the ports and controls on the front and rear of theswitch.

    Reset buttonThe Reset button is recessed within a hole on the front panel. Use a straightenedpaper clip or similar object to press the Reset button. The Reset button enables youto reset the switch, as follows:v Press Reset: The switch resets and reloads the configuration files.v Press and hold Reset for five seconds: The switch resets and configures all

    settings to the factory defaults.

    FansUp to four hot-swap fans cool the switch unit. Three fans are required for normaloperation. If an individual fan fails, the other fans continue to run, and the switchunit continues to operate normally. You can replace a hot-swap fan module whilethe switch is operating.

    Fan operation and internal temperatures are monitored. If the air temperatureexceeds a threshold, the environmental monitor displays warning messages.

    3117 57453321 61493725 554319 59473523 63513927 53412930 56443220 60483624 64524028 544218 58463422 62503826

    5 13

    91

    91

    135

    8 16

    124

    7 15

    113

    6 14

    102

    RackSwitch G8264

    ! S

    Mgmt

    17

    18

    19

    20

    21

    22

    23

    24

    25

    26

    27

    28

    29

    30

    31

    32

    33

    34

    35

    36

    37

    38

    39

    40

    49

    50

    51

    52

    53

    54

    55

    56

    57

    58

    59

    60

    61

    62

    63

    64

    41

    42

    43

    44

    45

    46

    47

    485-8

    1-4 9-12

    13-16

    SFP+ Ports

    QSFP+ Ports

    Figure 1. IBM RackSwitch G8264 front panel

    ! S

    MgmtReset Button

    RS-232 Port

    RJ-45 Port

    USB Port

    System Status LEDs

    Figure 2. IBM RackSwitch G8264 front panel detail

    OK

    ~AC

    !

    OK

    ~AC

    !

    Power Supply

    ModuleFan Modules

    IEC320

    Power Connector

    IEC320

    Power Connector

    Power Supply

    Module

    ProductInformationLabel

    Figure 3. IBM RackSwitch G8264 rear panel

    Chapter 1. Introduction 5

  • Note: If a fan module fails, the maximum operating temperature drops from +40Cto +35C (104F to 95F).

    The Service ( ! ) LED is lit if there is a failure of one or more fan modules. Thefailed fan module LED (rear panel) flashes to indicate a failure.AC power supplyThe switch has two hot-swap redundant 450 W AC power supplies. Each internalpower supply has an individual IEC 320 power connector on the rear panel. Thepower cord attaches to a universal grounded AC power source. You can replace ahot-swap power supply module without powering off the switch or disrupting switchfunctions.

    DANGER

    An electrical outlet that is not correctly wired could place hazardousvoltage on the metal parts of the system or the devices that attach to thesystem. It is the responsibility of the customer to ensure that the outlet iscorrectly wired and grounded to prevent an electrical shock. (D004)

    Each power supply can be connected to a separate AC circuit to mitigate the risk ofdown time during a power failure. When used in a redundant configuration, the dualpower supplies have a load-sharing capability that enables each power supply tooperate at approximately 50 percent of full load. Using redundant power canminimize the power disruption during a power supply failure and extend theexpected lifetime of each power supply by operating normally in a conservativepower mode.

    There is no power switch on the G8264; the switch unit powers up when power issupplied through the power cords.

    The Power Supply LED indicates the status of the power supplies. The LED flasheswhen only one power cord is connected, and is steady when both power cords areconnected.

    Switch portsThe RackSwitch ports and port options are described in the following sections.

    SFP+ ports

    6 IBM RackSwitch G8264: Installation Guide

  • CAUTION:This product might contain one or more of the following devices: CD-ROMdrive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1laser products. Note the following information:v Do not remove the covers. Removing the covers of the laser product could

    result in exposure to hazardous laser radiation. There are no serviceableparts inside the device.

    v Use of the controls or adjustments or performance of procedures otherthan those specified herein might result in hazardous radiation exposure.

    (C026)

    CAUTION:Data processing environments can contain equipment transmitting on systemlinks with laser modules that operate at greater than Class 1 power levels. Forthis reason, never look into the end of an optical fiber cable or openreceptacle. (C027)

    Forty-eight 10 GbE Small Form-factor Pluggable Plus (SFP+) ports are located onthe front panel. These ports accept supported optical or copper SFP or SFP+transceivers, or direct attach cables (DACs). Transceivers must be purchasedseparately.

    For the available transceivers and direct attach cables (DACs) for the switch, seehttps://www-01.ibm.com/products/hardware/configurator/americas/bhui/launchNI.wss.

    QSFP+ portsFour 40 GbE Quad Small Form-factor Pluggable Plus (QSFP+) ports are located onthe front panel. These ports accept supported optical QSFP+ transceivers or directattach cables (DACs). The supported transceivers interoperate with any40GBASE-SR4 compliant device, and support distances up to 100 meters on OM3fiber. Transceivers must be purchased separately.

    QSFP+ ports allow you to make one 40 GbE connection, or four 10 GbEconnections, using a breakout cable, as follows:v QSFP+ optical transceiver with MTP-to-4 LC (SFP+) fiber breakout cable. This

    option supports only 10GBASE-SR SFP+ transceivers. The 40GBASE-SR4specification (802.3ba-2010) indicates a higher optical power level than standard10GBASE-SR. SFP+ SR transceivers can handle the higher optical power levels.

    v QSFP+ to four 10 GbE SFP+ breakout DAC. The SFP+ connectors on supportedbreakout DACs are labelled A, B, C, and D, which correspond to the first,second, third, and fourth ports in the port range.

    For the available QSFP+ transceivers and DACs for the switch, seehttps://www-01.ibm.com/products/hardware/configurator/americas/bhui/launchNI.wss.

    Console portThe RS-232 (mini-USB) serial console port is located on the front panel. Thefollowing table describes the pinouts for the mini-USB port.

    Chapter 1. Introduction 7

  • Table 1. Console port connector pin assignmentsPin number FunctionPin 1 No connectPin 2 RS232-SINPin 3 RS232_SOUTPin 4 No connectPin 5 Ground

    8 IBM RackSwitch G8264: Installation Guide

  • The console cable provides an RJ-45 connector (see Table 2 for RJ-45 pinassignments). A retention clip is available to secure the console connection.

    The following table describes the pin assignments for the RJ-45 connector on theconsole cable.Table 2. RJ-45 connector pin assignmentsPin number Function1 RTS (Request To Send)2 DTR (Data Terminal Ready3 TxD (Transmit Data)4 GND (Ground)5 GND (Ground)6 RxD (Receive Data)7 DSR (Data Set Ready)8 CTS (Clear To Send)

    The following items are also included with the console cable.v Category 5 patch cablev RJ-45 to female DB9 adapter

    To connect a computer or terminal to the switch, first connect the console cable tothe mini-USB port on the front panel. Connect one end of the patch cable to theRJ-45 port on the console cable, and the other end of the patch cable to theRJ-45-to-DB9 adapter (see the following illustration).

    USB portThe USB port enables you to connect a USB drive to the switch. You can copy filesfrom the switch to the USB drive, or from the USB drive to the switch. You can alsostart the switch using files on the USB drive.

    For more information about using the USB drive, see the IBM System NetworkingRackSwitch G8264 Release Notes.

    To PC

    Terminal

    To

    Switch

    RJ-45 Adapter

    Category 5

    Patch Cable

    Switch

    Console Cable

    Figure 4. Console cable connections

    Chapter 1. Introduction 9

  • Switch LEDsTwo LED stacks provide system status and port link status. The following illustrationshows the system LEDs.

    The system LEDs are described in the following table.Table 3. System LEDsSymbol Description! Service LED

    Power supplies and power input status

    Fan status

    S Stacking indicator

    The following table describes the system LEDs.

    The following table describes the system LEDs.Table 4. System LED descriptionsFunction Service Power supply Fans StackingTotal PowerFailure

    Off Off Off Off

    Service Required Flash blue Flash green(Note 1)

    Flash green(Note 2)

    Flash green orsteady green(Note 3

    Power SuppliesOK

    Not applicable Steady green Not applicable Not applicable

    Power SupplyFailure

    Flash blue Flash green Not applicable Not applicable

    Fans OK Not applicable Not applicable Steady green Not applicableFan Failure Flash blue Not applicable Flash green Not applicableStack Master Off Not applicable Not applicable Flash greenStackBackup/Member

    On Not applicable Not applicable Steady green

    Stack Error Flash blue Not applicable Not applicable Flash green orsteady green

    Non-StackMember

    Off Not applicable Not applicable Off

    ! S

    Mgmt

    System Status LEDs

    Figure 5. System status LEDs

    10 IBM RackSwitch G8264: Installation Guide

  • Table 4. System LED descriptions (continued)Function Service Power supply Fans StackingOperationsCommand

    Steady blue(Note 4)

    Not applicable Not applicable Not applicable

    Note 1: If service required is due to a power supply failure, this LED flashes. Otherwise,it is steady green.Note 2: If service required is due to fan failure, this LED flashes. Otherwise, it is steadygreen.Note 3: If service required is due to a stacking error, this LED flashes or is steadygreen, depending on its last known good state.Note 4: If an operations command is sent to the unit, this LED is steady blue. It can beused to locate the device.

    RJ-45 LEDsThe RJ-45 LEDs are shown in the following illustration.

    RJ-45 port LEDs

    Link LED Activity LED

    Status LEDs for the RJ-45 ports are described in the following table.Table 5. RJ-45 LEDs statusLED Steady green Flashing Amber OffLink Link up Not applicable No linkActivity Not applicable Activity No activity

    SFP+ LEDsStatus LEDs for the SFP+ ports are described in the following table.Table 6. SFP+ LEDs statusSteady green Flash green OffLink up Activity No link

    QSFP+ LEDsThe QSFP+ LEDs are shown in the following illustration.

    Status LEDs for the QSFP+ ports are described in the following table. When theport is 40 GbE mode, only the first LED applies. When the port is in four 10 GbEmode, each LED provides status for its corresponding 10 GbE port, as noted in thefollowing table.

    5 13

    91

    91

    1358 16

    124

    7 15

    113

    6 14

    102! S

    Mgmt

    QSFP+LEDs

    Figure 6. QSFP+ LEDs

    Chapter 1. Introduction 11

  • Table 7. QSFP+ LEDs statusSteady green Flash green OffLink up Activity No Link

    Technical specificationsThe RackSwitch G8624 technical specifications are described in the followingsections.

    Physical characteristicsThe physical characteristics of the RackSwitch are listed in the following table.Table 8. Physical characteristicsSpecification Front-to-rear airflow Rear-to-front airflowDimensions (H x W x D) 4.4 x 43.9 x 51.3 cm.

    (1.73 x 17.3 x 20.2 in.)4.4 x 43.9 x 51.3 cm.(1.73 x 17.3 x 20.2 in.)

    Weight 10.5 kg. (23 lb) (maximum) 10.5 kg. (23 lb) (maximum)

    Environmental specificationsTable 9. Environmental specificationsSpecification MeasurementTemperature, ambient operating 0C to +40C (32 to 104F)Temperature (fan failure), operating 0C to +35C (32 to 95F)Temperature, storage -40C to +85C (-40 to 185F)Relative humidity (non-condensing),operating

    10 to 90%

    Relative humidity (non-condensing), storage 10 to 90%Altitude, operating 1,800 m (6,000 feet)Altitude, storage 12,190 m (40,000 feet)Acoustic noise Less than 65dBHeat dissipation 1127 BTU/hour (typical)

    1280 BTU/hour (maximum)

    Power specificationsThe AC power specifications for the switch are listed in the following table.Table 10. AC power specificationsSpecification MeasurementNumber of power supplies 2 (1+1 load sharing/redundant)AC-input frequency (universal) 50 - 60 HzAC-input voltage (universal) 100-240 VACAC inrush current 15 AAC-input current (typical) 2.75 A (RMS) @ 120 V

    1.435 A (RMS) @ 230 V

    12 IBM RackSwitch G8264: Installation Guide

  • Table 10. AC power specifications (continued)Specification MeasurementAC-input current (maximum) 3.125 A (RMS) @ 120 V

    1.630 A (RMS) @ 230 VPower supply rated output power 450 W eachSystem power dissipation (typical) 330 WSystem power dissipation (maximum) 375 WDC-output current 23.4 A (typical)

    Chapter 1. Introduction 13

  • 14 IBM RackSwitch G8264: Installation Guide

  • Chapter 2. Installing the RackSwitch and optionsThis chapter describes the how to install the RackSwitch chassis and theassociated RackSwitch components.v Installing the RackSwitch in the standard equipment rack on page 20v Installing the RackSwitch in the IBM iDataPlex rack on page 22v Installing the RackSwitch in an IBM System x or Power rack on page 24v Installing the 1U air duct option on page 28v Installing an SFP, SFP+, and QSFP+ transceiver on page 32

    Note: When replacing a RackSwitch chassis, all internal components must also beremoved from the chassis and replaced in the new chassis. For moreinformation on removing and replacing the RackSwitch and components, seeChapter 3, Removing and replacing the RackSwitch and components, onpage 37.

    Before installing the RackSwitchLocate and record the important product information about the switch in thefollowing table. The identification labels contain the machine-type model (MTM)number, serial number and part number (front, rear panel and/or bottom of the unit),and the media access control (MAC) address (rear of unit) for the switch. The MACaddress is not required for opening a service call.

    You can also review and record your product serial number and other requiredinformation through the software interface by issuing the show sys-info commandusing the ISCLI interface or the /info/sys/general command using the MenuCLIinterface. For more information about these commands, see Configuring VitalProduct Data after a switch replacement on page 46.

    After the switch is installed most of the identification labels are hidden from viewand require removing the switch in order to relocate them in the event of opening aservice call.

    Attention: This product information is required to register your product, to updateyour firmware, place a service call, and replace the RackSwitch.

    Note: The RackSwitch identification (ID) label may have different MTM numbersthan your unit. The following image is an example to help locate and identifythe ID label.

    Copyright IBM Corp. 2014 15

  • Record this information below and print this page and keep it in a safe place forpossible future reference. You will need this information when you register theswitch with IBM. You can register the switch at http://www.ibm.com/support/mysupport/.

    Product name IBM System Networking RackSwitch G8264Model number _____________________________________________Serial number _____________________________________________Part number _____________________________________________Media access control(MAC) address for switch

    _____________________________________________

    MAC addresses for othercomponents

    _____________________________________________

    _____________________________________________

    _____________________________________________

    Required toolsYou need the following tools or equipment to install the RackSwitch G8264:v Standard flat-blade screwdriverv #2 Phillips screwdriverv Electrostatic discharge wrist strap

    Package contentsThe basic package contains the following items:v One G8264 switch unit (one of the following):

    G8264 (front-to-rear) front-to-rear airflow G8264 (rear-to-front) rear-to-front airflow

    v One standard rack mount kit

    Figure 7. Sample RackSwitch ID labels

    16 IBM RackSwitch G8264: Installation Guide

  • Two brackets Screws to attach brackets to the switch unit Screws to attach the switch unit to the equipment rack

    v One mini-USB to RJ-45 serial cable, category 5 patch cable, RJ-45 to DB9adapter

    v Two AC power cordsv One IBM Documentation CD which includes the IBM RackSwitch G8264

    Installation Guide (this document)v One Environmental Notices CDv One Warranty Information documentv One Important Notices document

    Environmental requirementsThis section describes the basic environmental requirements for the RackSwitch.Make sure the location where you install he switch meets the followingrequirements:v Install the switch unit in a dry, clean, well-ventilated area.v Provide adequate space in the front and back of the switch unit, to ensure proper

    air flow.v Make sure that an adequate grounded power supply is within reach of the switch

    unit.v Make sure that twisted-pair cable is routed away from power lines, fluorescent

    lighting fixtures and other sources of electrical interference.

    Preventing electric shockThis product does not contain any user-serviceable parts. Do not remove the coverof this device.

    The Rackswitch AC power model is designed to work with single-phase powersystems that have a grounded neutral conductor. To reduce the risk of electricshock, always plug the power cord into a grounded power outlet.

    Chapter 2. Installing the RackSwitch and options 17

  • DANGER

    When working on or around the system, observe the following precautions:

    Electrical voltage and current from power, telephone, and communicationcables are hazardous. To avoid a shock hazard:v Connect power to this unit only with the provided power cord. Do not

    use the provided power cord for any other product.v Do not open or service any power supply assembly.v Do not connect or disconnect any cables or perform installation,

    maintenance, or reconfiguration of this product during an electricalstorm.

    v The product might be equipped with multiple power cords. To remove allhazardous voltages, disconnect all power cords.

    v Connect all power cords to a properly wired and grounded electricaloutlet. Ensure that the outlet supplies proper voltage and phase rotationaccording to the system rating plate.

    v Connect any equipment that will be attached to this product to properlywired outlets.

    v When possible, use one hand only to connect or disconnect signalcables.

    v Never turn on any equipment when there is evidence of fire, water, orstructural damage.

    v Disconnect the attached power cords, telecommunications systems,networks, and modems before you open the device covers, unlessinstructed otherwise in the installation and configuration procedures.

    v Connect and disconnect cables as described in the following procedureswhen installing, moving, or opening covers on this product or attacheddevices.To disconnect:1. Turn off everything (unless instructed otherwise).2. Remove the power cords from the outlets.3. Remove the signal cables from the connectors.4. Remove all cables from the devices.To connect:1. Turn off everything (unless instructed otherwise).2. Attach all cables to the devices.3. Attach the signal cables to the connectors.4. Attach the power cords to the outlets.5. Turn on the devices.(D005)

    18 IBM RackSwitch G8264: Installation Guide

  • Handling static-sensitive devicesAttention: Static electricity can damage the switch and other electronic devices.To avoid damage, keep static-sensitive devices in their static-protective packagesuntil you are ready to install them.

    To reduce the possibility of electrostatic discharge, observe the followingprecautions:v Limit your movement. Movement can cause static electricity to build up around

    you.v The use of a grounding system is recommended. For example, wear an

    electrostatic-discharge wrist strap, if one is available.v Handle the device carefully, holding it by its edges or its frame.v Do not touch solder joints, pins, or exposed printed circuitry.v Do not leave the device where others can handle and damage it.v While the device is still in its static-protective package, touch it to an unpainted

    metal part of any unpainted metal surface on a grounded rack component in therack in which you are installing the device, for at least 2 seconds. This drainsstatic electricity from the package and from your body.

    v Remove the device from its package and install it directly into the switch withoutsetting it down. If it is necessary to set down the device, put it back into itsstatic-protective package. Do not place the device on a switch cover or on ametal surface.

    v Take additional care when you handle devices during cold weather. Heatingreduces indoor humidity and increases static electricity.

    Chapter 2. Installing the RackSwitch and options 19

  • Installing the RackSwitch in the standard equipment rackThis section describes how to install the RackSwitch in a standard 19-inchequipment rack. For information about mounting the switch in other rack types, seethe following sections:v Installing the RackSwitch in the IBM iDataPlex rack on page 22v Installing the RackSwitch in an IBM System x or Power rack on page 24The following parts come in the standard mounting kit.Table 11. Standard rack mounting kit partsItem number Description Quantity1 M6 locking washers 42 M6 screws 43 M6 clip nuts 44 M6 cage nuts 45 M4 screws 86 Mounting bracket 2

    Attention: The rack-mounting frame may not be able to support the weight of thenetworking switch with only the front post mounting brackets (2-post application). Ifthe switch has an undesirable amount of sag, it is recommended to use a 4-postmounting kit.

    Attention: For earthquake stability, mount the switch in a 4-post rack.

    DANGERRack-mounted devices are not to be used as shelves or work spaces.

    (L002)

    To install the RackSwitch in a standard equipment rack, complete the followingsteps:1. Locate and record the product switch information to configure and register your

    product and set aside. See Before installing the RackSwitch on page 15.

    Note: If this switch is a replacement switch, copy the product information fromthe original switch onto the RID label that is shipped with replacementswitch and affix the new label to the bottom of the new switch.

    2. Use the M4 screws to attach a mounting bracket to each side of the switch.Torque the screws to approximately 2.0 newton-meters (Nm) +/- 0.1 Nm (17.7

    20 IBM RackSwitch G8264: Installation Guide

  • inch-pounds).

    56

    3. Slide the switch into the rack.4. Use the M6 screws, washers, and clip nuts (or cage nuts) to secure the switch

    unit to the rack. Torque the screws to approximately 5.7 Nm +/- 0.1 Nm (50inch-pounds).

    12

    3

    5. Connect all cables.6. Initialize the switch, see Chapter 4, Initializing the RackSwitch, on page 49.

    Attention: If this is a switch replacement, make sure the vital product data(VPD) is updated to avoid losing the licensed electronic entitlement data of theRackSwitch. For more information, see Configuring Vital Product Data after aswitch replacement on page 46.

    Chapter 2. Installing the RackSwitch and options 21

  • Installing the RackSwitch in the IBM iDataPlex rackThis section describes how to install the RackSwitch and switch components in theIBM iDataPlex rack. The iDataPlex mounting kit allows the switch to be mountedeither vertically or horizontally. For information about mounting the RackSwitch inother rack types, see the following sections:v Installing the RackSwitch in the standard equipment rack on page 20v Installing the RackSwitch in an IBM System x or Power rack on page 24

    The iDataPlex rack mount kit must be purchased separately.

    The following table lists the parts included in the iDataPlex mounting kit.Table 12. iDataPlex rack mount kit partsItem number Description Quantity1 Label 12 M6 locking washers 83 M6 screws 84 M6 clip nuts 85 M4 screws 166 Switch front bracket 27 Switch rear bracket 28 Rear mounting bracket 2

    DANGERRack-mounted devices are not to be used as shelves or work spaces.

    (L002)

    To install the RackSwitch in an iDataPlex rack, complete the following steps:1. Locate and record the product switch information to configure and register your

    product and set aside. See Before installing the RackSwitch on page 15.

    Note: If this switch is a replacement switch, copy the product information fromthe original switch onto the RID label that is shipped with replacementswitch and affix the new label to the bottom of the new switch.

    2. Use the M4 screws to attach front and rear mounting brackets to each side ofthe switch unit. Torque the screws to approximately 2 newton-meters (Nm) +/-0.1 Nm (17.7 inch-pounds).

    22 IBM RackSwitch G8264: Installation Guide

  • 6 5

    1

    7

    3. Use the M6 washers and screws to mount the switch unit into the rack. Torquethe screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).

    2

    3

    4

    4. Slide the RackSwitch into the rack.5. Use the M6 washers, screws, and clip nuts to attach the alignment plate. Torque

    the screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).

    8

    3

    2

    4

    10

    Chapter 2. Installing the RackSwitch and options 23

  • 6. Connect all cables.7. Initialize the switch, see Chapter 4, Initializing the RackSwitch, on page 49.

    Attention: If this is a switch replacement, make sure the VPD is updated toavoid losing the licensed electronic entitlement data of the RackSwitch. Formore information, see Configuring Vital Product Data after a switchreplacement on page 46.

    Installing the RackSwitch in an IBM System x or Power rackThis section describes how to install the RackSwitch in an IBM System Networkingadjustable 19 4-post rail rack (for Power and System x racks). For informationabout mounting the RackSwitch in other rack types, see the following sections:v Installing the RackSwitch in the standard equipment rack on page 20v Installing the RackSwitch in the IBM iDataPlex rack on page 22

    The IBM System Networking adjustable 19 4-post rail mount kit parts must bepurchased separately.

    The following table lists the parts included in the IBM System Networking adjustable19 4-post rail kit .Table 13. IBM System Networking adjustable 19 4-post rail mount kit partsItem number Description Quantity1 Label 12 M6 locking washers 83 M3 screws 44 M6 screws 85 M6 clip nuts 86 M6 cage nuts 87 M4 screws 168 Filler plate 19 Switch front bracket 210 Rear mounting bracket 111 Rear mounting bracket with

    cord exit1

    DANGERRack-mounted devices are not to be used as shelves or work spaces.

    (L002)

    24 IBM RackSwitch G8264: Installation Guide

  • To install the RackSwitch in an IBM System Networking adjustable 19 4-post railrack (for Power and System x racks), complete the following steps:1. Locate and record the product switch information to configure and register your

    product and set aside. See Before installing the RackSwitch on page 15.

    Note: If this switch is a replacement switch, copy the product information fromthe original switch onto the RID label that is shipped with replacementswitch and affix the new label to the bottom of the new switch.

    2. Use the M4 screws to attach the front mounting brackets to each side of theswitch. Torque the screws to approximately 2.0 newton-meters (Nm) +/- 0.1 Nm(17.7 inch-pounds).

    7

    1

    9

    9

    3. Use the M6 screws, washers, and clip nuts are used to connect the frontmounting brackets to the front and rear posts in the rack. Torque the screws toapproximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).

    Chapter 2. Installing the RackSwitch and options 25

  • 62

    4

    4. Slide the rear mounting brackets into the slots available on the front mountingbrackets.

    10

    11

    SEE STEP 5

    26 IBM RackSwitch G8264: Installation Guide

  • 5. Optional. Use the M6 washers, screws, and clip nuts to attach the filler plate tothe rear mounting brackets. Torque the screws to approximately 5.7 Nm +/- 0.1Nm (50 inch-pounds).

    4

    2

    68

    6. Use the M3 screws to secure the rear brackets to the front brackets. Torque thescrews to approximately 1.1 Nm +/- 0.1 Nm (10 inch-pounds).

    9

    10 11

    3

    7. Connect all the cables.8. Initialize the switch, see Chapter 4, Initializing the RackSwitch, on page 49.

    Attention: If this is a switch replacement, make sure that the vital productdata (VPD) is updated to avoid losing the licensed electronic entitlement data ofthe RackSwitch. For more information, see Configuring Vital Product Data aftera switch replacement on page 46.

    Chapter 2. Installing the RackSwitch and options 27

  • Installing the 1U air duct optionThe RackSwitch supports an optional 1U air duct to maximize air flow conditions inthe 19" rack. For 1U air duct option part numbers, see the Chapter 6, Replaceableswitch parts, on page 57 section.

    Mounting kit componentsThe 1U air duct option ships with:v One 1U air duct unitv One 1U air duct mechanical assembly kitv One power cord

    1

    7

    The following table lists the parts included with the 1U air duct mounting kit.Table 14. 1U air duct mounting kitItem number Description Quantity1 Cable tie 42 1U Duct sleeve (long) 13 Mounting bracket, right,

    assembly, 1U duct1

    4 Mounting bracket, left,assembly, 1U duct

    1

    5 Foam carrier assembly,includes half shears andfoam carrier

    2

    7 Screw, slotted, M3.5, 7 mm,flanged hex head

    6

    Attention: The rack-mounting frame may not be able to support the weight of thenetworking switch with only the front post mounting brackets (2-post application). Ifthe switch has an undesirable amount of sag, it is recommended to use a 4-postmounting kit.

    28 IBM RackSwitch G8264: Installation Guide

  • Attention: For earthquake stability, mount the switch in a 4-post rack.

    DANGERRack-mounted devices are not to be used as shelves or work spaces.

    (L002)

    To install the 1U air duct option in a 19" rack, complete the following steps.1. Loosen and remove the mounting screws from the both sides of the mounting

    rail and set aside to reuse to secure the foam carrier.

    Half shear

    Foam carrier snug against rear of unit

    Reuse mounting screws

    Mounting screws

    2. Place the half shears on the rear side of the foam carriers and use the M3.5mounting rail screws to secure the foam carrier assemblies snugly against therear of the RackSwitch unit. Torque the screws to approximately 1.1 Nm +/- 0.1Nm (10 inch-pounds).

    Note: There are additional M3.5 screws in the air duct assembly kit.3. Plug the power cords into their respective RackSwitch power cord connectors

    and using the tie wraps, secure the power cords to the mounting rails.

    Chapter 2. Installing the RackSwitch and options 29

  • Tie wraps

    Tie wraps

    Power connection

    Power connection

    4. Use the M6 screws to secure the air duct brackets to the mounting rails. Torquethe screws to approximately 5.7 Nm +/- 0.1 Nm (50 inch-pounds).

    Air duct mounting bracket

    M6 screws

    M3.5 screws

    5. Use the M3.5 screws to secure the air duct mounting bracket to the rackchassis. Torque the screws to approximately 1.1 Nm +/- 0.1 Nm (10inch-pounds).

    6. Gently slide the air duct unit side flanges into the card guides until the unit isseated firmly. Make sure that the foam strip is oriented on top.

    30 IBM RackSwitch G8264: Installation Guide

  • M4thumbscrews

    Side flanges

    Card guides

    Foam

    7. Use the two M4 thumbscrews to secure the air duct unit to the air duct brackets.

    For information about removing the air duct, see Removing the 1U air duct optionon page 45.

    Chapter 2. Installing the RackSwitch and options 31

  • Installing an SFP, SFP+, and QSFP+ transceiverThe RackSwitch G8264 supports copper and fiber transceivers. For the availabletransceivers for the switch, see https://www-01.ibm.com/products/hardware/configurator/americas/bhui/launchNI.wss.

    To install a transceiver, see the following sections:v Installing an SFP copper transceiverv Installing an SFP optical transceiverv Installing an SFP+ optical transceiver on page 33v Installing a QSFP+ optical transceiver on page 34

    Installing an SFP copper transceiverThe SFP copper transceiver provides an RJ-45 connector that accepts a standard10/100/1000BASE-T (category 5) cable.

    To install an SFP copper transceiver in a 1 Gbps SFP or SFP+ port on the G8264switch unit, complete the following steps.

    Note: To avoid damage to the cable or the SFP transceiver, do not connect thecable before you install the transceiver.

    1. Remove the safety cap and pull the locking lever into the down (unlocked)position.

    2. Insert the transceiver into the port until it clicks into place. Use minimal pressurewhen you insert the transceiver into the slot. Do not use excessive force whenyou insert the transceiver; you can damage the transceiver or the SFP slot.The transceiver has a mechanical guide key to prevent you from inserting thetransceiver incorrectly.

    3. Pull up the locking lever to lock the transceiver into place.4. Connect the cable.

    To remove a SFP copper transceiver, disconnect the cable, and pull down thelocking lever to release the transceiver. After you remove the transceiver,replace the safety cap.

    Installing an SFP optical transceiverThe SFP optical transceiver provides two fiber-optic cable connectors for connectingto external ports.

    32 IBM RackSwitch G8264: Installation Guide

  • CAUTION:This product might contain one or more of the following devices: CD-ROMdrive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1laser products. Note the following information:v Do not remove the covers. Removing the covers of the laser product could

    result in exposure to hazardous laser radiation. There are no serviceableparts inside the device.

    v Use of the controls or adjustments or performance of procedures otherthan those specified herein might result in hazardous radiation exposure.

    (C026)

    CAUTION:Data processing environments can contain equipment transmitting on systemlinks with laser modules that operate at greater than Class 1 power levels. Forthis reason, never look into the end of an optical fiber cable or openreceptacle. (C027)

    To install an SFP optical transceiver in a 1 Gbps SFP slot on the G8264 switch unit,complete the following steps.

    Note: To avoid damage to the cable or the SFP transceiver, do not connect thecable before you install the transceiver.

    1. Remove the safety cap and pull the locking lever into the down (unlocked)position.

    2. Insert the transceiver into the port until it clicks into place. Use minimal pressurewhen you insert the transceiver into the slot. Do not use excessive force whenyou insert the transceiver; you can damage the transceiver or the SFP slot.The transceiver has a mechanical guide key to prevent you from inserting thetransceiver incorrectly.

    3. Pull up the locking lever to lock the transceiver into place.4. Connect the fiber-optic cable.

    To remove a SFP optical transceiver, disconnect the fiber-optic cable, and pulldown the locking lever to release the transceiver. After you remove thetransceiver, replace the safety cap.

    Installing an SFP+ optical transceiverThe SFP+ ports accept supported SFP+ transceivers. The SFP+ optical transceiverprovides two fiber-optic cable connectors for connecting to external ports.

    Chapter 2. Installing the RackSwitch and options 33

  • CAUTION:This product might contain one or more of the following devices: CD-ROMdrive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1laser products. Note the following information:v Do not remove the covers. Removing the covers of the laser product could

    result in exposure to hazardous laser radiation. There are no serviceableparts inside the device.

    v Use of the controls or adjustments or performance of procedures otherthan those specified herein might result in hazardous radiation exposure.

    (C026)

    CAUTION:Data processing environments can contain equipment transmitting on systemlinks with laser modules that operate at greater than Class 1 power levels. Forthis reason, never look into the end of an optical fiber cable or openreceptacle. (C027)

    To install an SFP+ optical transceiver in an SFP+ port, complete the following steps.

    Note: To avoid damage to the cable or the SFP transceiver, do not connect thecable before you install the transceiver.

    1. Remove the safety cap and pull the locking lever into the down (unlocked)position.

    2. Insert the transceiver into the port until it clicks into place. Use minimal pressurewhen you insert the transceiver into the slot. Do not use excessive force whenyou insert the transceiver; you can damage the transceiver or the SFP+ slot.The transceiver has a mechanical guide key to prevent you from inserting thetransceiver incorrectly.

    3. Pull up the locking lever to lock the transceiver into place.4. Connect the fiber-optic cable.

    To remove a SFP+ optical transceiver, disconnect the fiber-optic cable, and pulldown the locking lever to release the transceiver. After you remove thetransceiver, replace the safety cap.

    Installing a QSFP+ optical transceiverThe QSFP+ ports accept supported QSFP+ transceivers. The QSFP+ opticaltransceiver provides an MTP cable connector for connecting to external ports.

    34 IBM RackSwitch G8264: Installation Guide

  • CAUTION:This product might contain one or more of the following devices: CD-ROMdrive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1laser products. Note the following information:v Do not remove the covers. Removing the covers of the laser product could

    result in exposure to hazardous laser radiation. There are no serviceableparts inside the device.

    v Use of the controls or adjustments or performance of procedures otherthan those specified herein might result in hazardous radiation exposure.

    (C026)

    CAUTION:Data processing environments can contain equipment transmitting on systemlinks with laser modules that operate at greater than Class 1 power levels. Forthis reason, never look into the end of an optical fiber cable or openreceptacle. (C027)

    To install a QSFP+ optical transceiver in a QSFP+ port, complete the followingsteps.

    Note: To avoid damage to the cable or the SFP transceiver, do not connect thecable before you install the transceiver.

    1. Remove the safety cap and pull the locking lever into the down (unlocked)position.

    2. Insert the transceiver into the port until it clicks into place. Use minimal pressurewhen you insert the transceiver into the slot. Do not use excessive force whenyou insert the transceiver; you can damage the transceiver or the QSFP+ slot.The transceiver has a mechanical guide key to prevent you from inserting thetransceiver incorrectly.

    3. Pull up the locking lever to lock the transceiver into place.4. Connect the fiber-optic cable.

    To remove a QSFP+ optical transceiver, disconnect the fiber-optic cable, andpull down the locking lever to release the transceiver. After you remove thetransceiver, replace the safety cap.

    Chapter 2. Installing the RackSwitch and options 35

  • 36 IBM RackSwitch G8264: Installation Guide

  • Chapter 3. Removing and replacing the RackSwitch andcomponents

    This chapter describes the how to remove and replace the RackSwitch chassis andthe associated RackSwitch components, such as, a fan module, and options, suchas, the 1U air duct option.

    When replacing a RackSwitch chassis, all internal components must also beremoved from the chassis and replaced in the new chassis.

    For more information to remove and replace the RackSwitch, components andoptions, see the following sections.v Removing and replacing the RackSwitch chassis unit from a rackv Removing the AC power supply module on page 43v Replacing the AC power supply module on page 43v Removing the fan module on page 44v Replacing the fan module on page 45v Removing the 1U air duct option on page 45v Removing and replacing the main RackSwitch chassis unit on page 46

    Removing and replacing the RackSwitch chassis unit from a rackThis section describes how to remove the RackSwitch chassis unit from supportedequipment racks. For information about removing the RackSwitch from differentracks, see the following sections:v Removing the RackSwitch chassis from a standard equipment rackv Removing the RackSwitch chassis from a System x or Power rack on page 39v Removing the RackSwitch chassis from an iDataPlex rack on page 41

    Removing the RackSwitch chassis from a standard equipment rackTo remove the RackSwitch from a standard equipment rack, complete the followingsteps:1. Disconnect all cables.2. Loosen and remove the M6 screws, washers, and clip nuts (or cage nuts) to

    remove the switch unit from the rack.

    12

    3

    Copyright IBM Corp. 2014 37

  • 3. Slide the switch out of the rack.

    38 IBM RackSwitch G8264: Installation Guide

  • 4. Loosen and remove the M4 screws attaching the mounting bracket on each sideof the switch.

    56

    Removing the RackSwitch chassis from a System x or Power rackTo remove the RackSwitch from a System x or Power rack, complete the followingsteps:1. Disconnect all the cables.2. Loosen and remove the M6 screws that secure the rear brackets to the front

    brackets.

    9

    10 11

    3

    3. Slide the rear mounting brackets out of the slots available on the front mountingbrackets.

    Chapter 3. Removing and replacing the RackSwitch and components 39

  • 10

    11

    SEE STEP 5

    4. Loosen and remove the M6 screws, washers, and clip nuts are used to connectthe front mounting brackets to the front and rear posts in the rack.

    6

    2

    4

    5. Slide the RackSwitch out of the rack.

    40 IBM RackSwitch G8264: Installation Guide

  • 6. Loosen and remove the M4 screws that attach the front mounting brackets toeach side of the switch.

    7

    1

    9

    9

    Removing the RackSwitch chassis from an iDataPlex rackTo remove the RackSwitch from the iDataPlex rack, complete the following steps:1. Disconnect all cables.2. Loosen and remove the M6 washers, screws, and clip nuts that attach the

    alignment plate.

    8

    3

    2

    4

    10

    3. Loosen and remove the M6 washers and screws that mount the switch unit intothe rack.

    Chapter 3. Removing and replacing the RackSwitch and components 41

  • 23

    4

    4. Slide the RackSwitch out of the rack.5. Loosen and remove the M4 screws that attach front and rear mounting brackets

    to each side of the switch unit.

    6 5

    1

    7

    Removing and replacing the power supply moduleThe RackSwitch G8264 operates with either one or two active power supplymodules. You can replace a hot-swap power supply module without powering offthe switch or disrupting switch functions.

    You can operate the switch with two AC power supply modules, or one powersupply module and a blank cover. For correct airflow, both power supply slots mustbe populated with either a power supply module or a blank module.

    Each AC power supply module has a power cord for connection to an AC poweroutlet.

    Each power supply module has three LEDs that are visible from the rear panel. Thefollowing table describes the LEDs.

    42 IBM RackSwitch G8264: Installation Guide

  • Table 15. Power supply module LEDsLED status DescriptionOKGreen DC output power is present.Off DC output power is OK.Service ( ! )Amber Power supply or fan module failure.Off Power supply and fan modules are

    operational.~ AC InputGreen AC power is OK.Off No power. Output is disabled or input power

    is out of operating range.

    Removing the AC power supply moduleTo remove a power supply module, complete the following steps:1. Remove the power cord from the power connector.2. Press the release latch of the power supply module, and slide the module out of

    the slot.

    Release latch

    Attention: Do not leave the power-supply slot empty for more than 90seconds while the switch is operating.

    To return the component to customer service for replacement, see Appendix A,Getting help and technical assistance, on page 65, to help you gather all therequired information that is necessary to return a component. After you remove thecomponent, securely pack the component for shipping.

    Replacing the AC power supply moduleTo replace an AC power supply module, complete the following steps:1. Insert the power supply module into the power-supply slot, and gently push it

    into the slot until it latches. Each power supply module has a mechanical guidekey to prevent you from inserting the module incorrectly.

    Chapter 3. Removing and replacing the RackSwitch and components 43

  • Release latch

    2. Connect the power cord to the power supply module and to an AC powersource.

    3. Turn on the power at the power source.4. Make sure that the power supply OK and AC LEDs are green.

    Removing and replacing the fan moduleThe RackSwitch G8264 contains up to four hot-swap fan modules.

    The switch continues to operate when there is one failed fan module. If one fanfails, the switch sends an error message. If a second fan fails, the switch sends anerror message, writes a failure log to flash memory, and shuts down.

    Each fan module has a green LED that is visible from the rear panel. The LEDshows the status of the fan module, as follows:Table 16. Fan LED statesLED state DescriptionLit Fans are operational.Off Fan unit has no power.Flashes Fan speed has failed. Replace the fan

    module.

    Removing the fan moduleTo remove a fan module, complete the following steps:1. Loosen the retainer screw.2. Grasp the extractor handle and gently pull the fan module from the slot.

    Attention: Replace the fan module within 5 minutes to avoid overheating theswitch.

    44 IBM RackSwitch G8264: Installation Guide

  • To return the component to customer service for replacement, see Appendix A,Getting help and technical assistance, on page 65, to help you gather all therequired information that is necessary to return a component. After you remove thecomponent, securely pack the component for shipping.

    Replacing the fan moduleTo replace a fan module, complete the following steps:1. If necessary, remove the filler plate from the appropriate slot. Loosen the

    retainer screws and slide the filler plate out of the slot.2. Remove the fan module from the antistatic shielded bag.3. Slide the fan module into the card guides in the open slot and gently push it all

    the way into the slot, so that it firmly engages with the connector (see theillustration). Each fan module has a mechanical guide key to prevent you frominserting the module incorrectly.

    4. Tighten the retaining screw on the fan module. Torque the screw toapproximately 0.25 Nm +/- 0.1 Nm (2 inch-pounds).

    Removing the 1U air duct optionTo remove the 1U air duct option from a 19" rack, complete the following steps.1. Loosen the two M4 thumbscrews securing the air duct unit to the air duct

    brackets.

    M4thumbscrews

    2. Slide the air duct unit out of the rack.

    Chapter 3. Removing and replacing the RackSwitch and components 45

  • To return the component to customer service for replacement, see Appendix A,Getting help and technical assistance, on page 65, to help you gather all therequired information that is necessary to return a component. After you remove thecomponent, securely pack the component for shipping.

    For instructions to replace the air duct, see Installing the 1U air duct option onpage 28.

    Removing and replacing the main RackSwitch chassis unitWhen replacing a RackSwitch chassis unit, all internal component must also beremoved from the chassis and replaced in the new chassis. The RackSwitchoperates with one or two active power supplies, up to four fan modules, and anoptional air duct unit.

    When you remove a RackSwitch unit from the rack, record the product MTMnumber and serial number to use for the replacement switch, see Before installingthe RackSwitch on page 15 to locate the product information labels on the switchchassis or Configuring Vital Product Data after a switch replacement to use aninterface to display the product information for the RackSwitch.

    Before you replace the RackSwitch chassis, you must remove and replace theseparate components. For more information about removing and replacingRackSwitch components, see the following sections:v Removing and replacing the power supply module on page 42v Removing and replacing the fan module on page 44

    To return the chassis to customer service for replacement, see Appendix A, Gettinghelp and technical assistance, on page 65, to help you gather all the requiredinformation that is necessary to return a component. After you remove the chassisunit, securely pack the RackSwitch unit for shipping.

    To replace the RackSwitch chassis in the rack, see the following procedures andperform them in the order in which they are listed.v Replacing the AC power supply module on page 43v Replacing the fan module on page 45v Chapter 2, Installing the RackSwitch and options, on page 15

    Configuring Vital Product Data after a switch replacementAfter you replace a RackSwitch, you must update the new switch with the VPD ofthe RackSwitch being removed to avoid losing the licensed electronic entitlementdata of the RackSwitch. The VPD includes the model and serial number of theswitch. For more information on locating the VPD, see Before installing theRackSwitch on page 15.

    To update the VPD on a new switch, complete the following steps.1. Log in to the switch and in the CLI mode, type

    RS G8264>ibmnos

    2. At the Password prompt, enter the switch password, and press Enter. Thedefault password is admin.

    46 IBM RackSwitch G8264: Installation Guide

  • 3. In the main menu, enter the machine-type model (MTM) number for thereplacement switch. For example:/boot/mtm 1455-64C

    where 1455-64C is the MTM of the unit that is being replaced4. Enter the serial number for the replacement switch. For example:

    /boot/esn 1000001

    where 1000001 is the serial number of the unit that is being replaced.5. Reset the switch using the following command:

    /boot/reset

    6. When prompted to confirm the reset, enter y. The switch reboots.7. After the switch reboots, at the command prompt, verify that the VPD

    information is correct by issuing the show sys-info command using the ISCLIinterface or the /info/sys/general command using MenuCLI interface.ISCLI interface output example:show sys-info

    System Information at 13:41:04 Fri Jan 20, 2011Time zone: America/US/PacificDaylight Savings Time Status: DisabledIBM System Networking RackSwitch G8264Switch has been up for 0 days, 17 hours, 10 minutes and 45 seconds.Last boot: 20:41:01 Thu Jan 19, 2011 (power cycle)MAC address: fc:cf:62:9d:2b:00 IP (If 1) address: 0.0.0.0Management Port MAC Address: fc:cf:62:9d:2b:feManagement Port IP Address (if 128): 203.203.21.2Hardware Revision: 0Hardware Part No: BAC-000*a*00Switch Serial No: US7C45t78Manufacturing date:Software Version 6.6.0 (FLASH image1), active configuration.Temperature Mother Top: 34 CTemperature Mother Bottom: 38 CTemperature Daughter Top: 35 CTemperature Daughter Bottom: 37 CWarning at 70 C and Recover at 100 CFan 1 in Module 1: RPM=17647 PWM=255(100%) Front-To-BackFan 2 in Module 1: RPM= 9310 PWM=255(100%) Front-To-BackFan 3 in Module 2: RPM=17419 PWM=255(100%) Front-To-BackFan 4 in Module 2: RPM= 9326 PWM=255(100%) Front-To-BackFan 5 in Module 3: RPM=17197 PWM=255(100%) Front-To-BackFan 6 in Module 3: RPM= 9523 PWM=255(100%) Front-To-BackFan 7 in Module 4: RPM=17252 PWM=255(100%) Front-To-BackFan 8 in Module 4: RPM= 9490 PWM=255(100%) Front-To-BackSystem Fan Airflow: Front-To-BackPower Supply 1: Vin FaultPower Supply 2: OK

    OrMenuCLI interface output example:/info/sys/general

    Chapter 3. Removing and replacing the RackSwitch and components 47

  • System Information at 0:16:42 Wed Jan 3, 2012Time zone: America/US/PacificDaylight Savings Time Status: DisabledIBM System Networking RackSwitch G8264Switch has been up 5 days, 2 hours, 16 minutes and 42 seconds.Last boot: 0:00:47 Wed Jan 3, 2012 (reset from console)MAC address: 00:00:00:00:00:00 IP (If 1) address: 0.0.0.0Internal Management Port MAC Address: 00:00:00:00:00:efInternal Management Port IP Address (if 128): 9.43.95.121External Management Port MAC Address: 00:00:00:00:00:feExternal Management Port IP Address (if 127):Software Version 7.5.0 (FLASH image2), active configuration.Hardware Part Number: 46C7193Hardware Revision: 05Serial Number: PROTO2C04EManufacturing Date: 43/08PCBA Part Number: BAC-00072-00PCBA Revision: 0PCBA Number: 00Board Revision: 05PLD Firmware Version: 1.3Temperature Warning: 26 C (Warn at 60 C/Recover at 55 C)Temperature Shutdown: 27 C (Shutdown at 65 C/Recover at 60 C)Temperature Inlet: 23 CTemperature Exhaust: 26 CPower Consumption: 42.570 W (12.000 V, 3.543 A)Switch is in I/O Module Bay 1

    For more information about using the switch interface, see the Configurationguide for your interface.

    48 IBM RackSwitch G8264: Installation Guide

  • Chapter 4. Initializing the RackSwitchWhen you supply power to the RackSwitch, the switch initializes automatically.

    DANGERMultiple power cords. The product might be equipped with multiple powercords. To remove all hazardous voltages, disconnect all power cords.

    (L003)1 2

    or

    !

    1

    2

    The following LEDs indicate the overall system status:v Power Supply: Steady green if both power cords are connected, flashing green if

    only one power cord is connected.v Service ( ! ): Off if the system is OK, flashing if service is required.

    Use the mini-USB console cable to connect the RS-232 serial port on the switchunit front panel to a terminal or a computer running a terminal emulation program.You can access the command-line interface to perform initial configuration tasks.

    To access the switch CLI and perform initial configuration tasks, use one of thefollowing methods:

    Copyright IBM Corp. 2014 49

  • v Connect an Ethernet cable to the RJ-45 management port and use Telnet,SNMP, or a Web browser to access the CLI through the IP address provided bythe networks DHCP server.

    v Connect the mini-USB console cable to the RS-232 serial port on the switchunits front panel, and use a terminal or a computer running a terminal emulationprogram to access the switch CLI.

    The console port terminal-emulation requirements are as follows:v Default baud rate = 9,600 bpsv Character size = 8 charactersv Parity = nonev Stop bits = 1v Data bits = 8v Flow control = none

    The switch performs initial self tests, and displays the password prompt, similar tothe following screen:Memory Test ................................Production ModePPCBoot 0.0.0.10 (new flash)Memory Test (0x00) .............................PASSED

    ...IBM System Networking RS G8264

    Jan 1 00:01:27 2013:NOTICE-5:Interface Oper Status Indication - Port 7 State UP

    Password:

    At the Password prompt, enter the switch password, and press Enter. The defaultpassword is admin.

    Default configurationThe switch software contains default factory-loaded configuration files. The defaultconfiguration is part of the software; it cannot be deleted or changed. The defaultsettings allow the switch to perform basic functions with minimal effort by thesystem administrator. DHCP is enabled by default on the management interfacesand BOOTP is enabled by default on interface 1. If there is no DHCP offer received,the device uses the default Mgmt _IP address (192.168.50.50/24). This address isoverwritten when a DHCP/BOOTP address is received for that interface. IfDHCP/BOOTP is enabled and there is no static address configured forDHCP/BOOTP requests will continue to be sent. This feature does not changeexisting DHCP/BOOTP functionality. See the following initial configuration example:

    50 IBM RackSwitch G8264: Installation Guide

  • RS G8264# show inter ipInterface information:1: IP4 192.168.49.50 255.255.255.0 192.168.49.255, vlan 1, up128: IP4 192.168.50.50 255.255.255.0 192.168.50.255, vlan 4095, up! interface ip 1! addr ! enable!! interface ip 128! addr ! enable

    RS G8264(config)# system dhcp?

    mgt dhcp on mgt portRS G8264(config)# system dhcp mgt

    Warning: Enabling dhcp will overwrite IP interface 128 and IP gateway 4 configurations.RS G8264# show inter ip

    Interface information:1: IP4 192.168.49.50 255.255.255.0 192.168.49.255, vlan 1, up128: IP4 192.168.50.50 255.255.255.0 192.168.50.255, vlan 4095, up

    Configuring an IP interfaceTo manage the switch using Telnet, SNMP, or a web browser, you must configurean IP interface. Configure the following IP parameters:v IP addressv Subnet maskv Gateway address1. Log on to the switch.2. Enter IP interface mode.

    RS G8264> enableRS G8264# configure terminalRS G8264 (config)# interface ip 1

    3. Configure an IP interface, subnet mask, and VLAN assignment. Enable theinterface.RS G8264 (config-ip-if)# ip address 10.10.10.2 (example IP address)RS G8264 (config-ip-if)# ip netmask 255.255.255.0RS G8264 (config-ip-if)# vlan 1RS G8264 (config-ip-if)# enableRS G8264 (config-ip-if)# exit

    4. Configure the default gateway. Enable the gateway.RS G8264 (config)# ip gateway 1 address 10.10.10.1 (example gateway address)RS G8264 (config)# ip gateway 1 enable

    After you configure the IP address for your switch and you have an existingnetwork connection, you can use the Telnet program from an externalmanagement station to access and control the switch. The management stationand your switch must be on the same IP subnet.The G8264 Rackswitch supports a command-line interface (CLI) that you canuse to configure and control the switch over the network using the Telnetprogram. You can use the CLI to perform many basic network management

    Chapter 4. Initializing the RackSwitch 51

  • functions. In addition, you can configure the switch for management by using anSNMP-based network management system or a web browser.For more information about using the CLI, see the Command Reference for theswitch.

    Updating firmwareIf firmware updates are available, you can download them fromhttp://www.ibm.com/supportportal/. The switch might have features that are notdescribed in the documentation that comes with the switch, and the documentationmight be updated occasionally to include information about those features, ortechnical updates might be available to provide additional information that is notincluded in the switch documentation.

    Configuration settings are lost during a firmware update. Before updating thefirmware, save a copy of the configuration on a separate device. In the event of afailed update, the saved configuration can be restored. For more information aboutthe configuration file, see the Application Guide and Command Reference for theswitch.

    Attention: Installing the wrong firmware update might cause the network switch tomalfunction. Before you install a firmware, read any readme and change historyfiles that are provided with the downloaded update. These files contain importantinformation about the update and the procedure for installing the update, includingany special procedure for updating from an early firmware version to the latestversion.

    To check for firmware updates, go to http://www.ibm.com/supportportal/ and clickDownloads.

    Note: Changes are made periodically to the IBM website. Procedures for locatingfirmware might vary slightly from what is described in this document.

    Using the Boot Management menuThe Boot Management menu enables you to switch the software image, reset theswitch to factory defaults, or to recover from a failed software download.

    You can interrupt the boot process and enter the Boot Management menu from theserial console port. When the system displays Memory Test, press Shift+B. TheBoot Management menu is displayed.Resetting the System ...Memory Test ................................

    Boot Management Menu1 - Change booting image2 - Change configuration block3 - Xmodem download4 - Exit

    Please choose your menu option: 1Current boot image is 1. Enter image to boot: 1 or 2: 2Booting from image 2

    The Boot Management menu allows you to perform the following actions:v To change the boot image, press 1 and follow the screen prompts.

    52 IBM RackSwitch G8264: Installation Guide

  • v To change the configuration block, press 2, and follow the screen prompts.v To perform an Xmodem download, press 3 and follow the screen prompts.v To exit the Boot Management menu, press 4. The boot process continues.

    Chapter 4. Initializing the RackSwitch 53

  • 54 IBM RackSwitch G8264: Installation Guide

  • Chapter 5. TroubleshootingThis section contains basic troubleshooting information to help resolve problemsthat might occur during installation and operation of the switch. If you haveproblems accessing the switch or working with the software, see the RackSwitchG8264 Command Reference.

    For information about calling IBM for service, see Appendix A, Getting help andtechnical assistance, on page 65.

    System LED is not litSymptom: The power supply LED is not lit.

    Solution: Check the power supply to make sure that there is a proper connectionto the power source. Make sure that power is available from the power source.

    Port link LED is not litSymptom: The port link LED is not lit.

    Solution 1: Check the port configuration in the software (see the CommandReference). If the port is configured with a specific speed or duplex mode, checkthe other device to make sure that it is set to the same configuration. If the switchport is set to autonegotiate, make sure that the other device is set to autonegotiate.

    Solution 2: Check the cables that connect the port to the other device. Make surethat they are connected correctly. Make sure that you are using the correct cabletype.

    Temperature sensor warningSymptom: A temperature warning is displayed on the management console.

    Solution: Make sure that the air circulation vents on the front, back, and sides ofthe switch are free from obstruction by cables, panels, rack frames, or othermaterials.

    Make sure that all cooling fans inside the switch are running. A fan module LED(rear panel) flashes if there is a failure of the fan. The following command displaysfan status:show sys-info

    If any fan stops during switch operation, contact Customer Support.

    Switch does not initialize (boot)Symptom: All the switch LEDs stay on, and the command prompt is not displayedon the console.

    Solution: The operating system might be damaged. Use the console port toperform a serial upgrade of the switch software. See the Command Reference.

    Copyright IBM Corp. 2014 55

  • 56 IBM RackSwitch G8264: Installation Guide

  • Chapter 6. Replaceable switch partsThe replaceable switch parts are Tier 1 customer replaceable units (CRUs).Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU atyour request, you will be charged for the installation.

    For information about the terms of the warranty, see the Warranty Informationdocument that comes with the switch. For more information about getting serviceand assistance, see Appendix A, Getting help and technical assistance, on page65.

    Table 17. IBM System Networking RackSwitch G8264, Model 7309-xxx replaceable parts

    Description ModelOption partnumber

    Tier 1 CRU partnumber

    Switch, G8264 base 7309-64F7309-G647309-HC37309-HC4

    Not applicable 00D9800

    Power supplies110/220 V, front-to-rear airflow 7309-64F

    7309-HC449Y7937 00D6270

    110/220 V, rear-to-front airflow 7309-G647309-HC3

    49Y7938 00D6271

    Fan modulesFront-to-rear airflow 7309-64F

    7309-HC400FE289 49Y7939

    Rear-to-front airflow 7309-G647309-HC3

    00FE291 88Y6026

    TransceiversSFP 1000BASE-T (RJ-45) 7309-64F

    7309-G647309-HC37309-HC4

    81Y1618 81Y1620

    SFP 1000BASE-LX 7309-64F7309-G647309-HC37309-HC4

    90Y9424 90Y9423

    SFP 1000BASE-SX 7309-64F7309-G647309-HC37309-HC4

    81Y1622 81Y1624

    SF