gamma camera (acquisitions). mono-isotope e 1 =140kev(tc 99m ) ± 10% e1e1 n e

27
GAMMA CAMERA (acquisitions)

Upload: alfonse-metayer

Post on 04-Apr-2015

106 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

GAMMA CAMERA

(acquisitions)

Page 2: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

mono-isotope

E1=140keV(Tc99m) ± 10%

E1

N

E

Page 3: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

double-isotope

E1=140keV(Tc99m) ± 10% E2=190keV(Kr81m) ± 10%

E1 E2 N

E

Page 4: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

double-isotope

E1=140keV(Tc99m) -10%+7.5%

E21=117keV(In111) -7.5%+10% + E2

2=245keV(In111) ± 10%

N

E

E1 E21

E22

Page 5: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

double-isotope

tumeur In111 os Tc99m somme

tumeur In111 os Tc99m somme

échelle de gris

échelle bicolore

Page 6: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition champ séparé (translation manuelle)

Acquisition champs séparés (rotation manuelle)

Acquisition corps entier (translation automatique)

Acquisition dynamique

Acquisition synchronisée avec le signal ECG

Acquisition tomographique (SPECT)

Page 7: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition champ séparé (translation manuelle)

Page 8: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition champ séparé (translation manuelle)

thyroïde

Page 9: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition champ séparé (translation manuelle)

tête

Page 10: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition champ séparé (translation manuelle)

thorax

Page 11: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition champ séparé (translation manuelle)

basin

Page 12: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition champ séparé (translation manuelle)

pied

Page 13: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

(rotation manuelle)Acquisition champs séparés

Page 14: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

antérieur (ANT)

oblique

postérieur gauche

(OPG)

postérieur (POST)

oblique

postérieur droit

(OPD)

(rotation manuelle)Acquisition champs séparés

Page 15: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition corps entier (translation automatique)

Page 16: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition corps entier (translation automatique)

Page 17: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition dynamique

Page 18: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

T = 0

t . . . . . . . . . .

début des mesures à T = 0,

durée d’une mesure t

durée totale N *t

Acquisition dynamique

Page 19: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

Acquisition synchronisée avec le signal ECG

Page 20: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

signal ECG

R RR - R

QS

Page 21: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

synchronisation

R RR - R

départ comptage 1

départ comptage 2

départ comptage 3

départ comptage N-1

départ comptage N

Page 22: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

nombre d’images et temps d’acquisition

R RR - R

Temps d’acquisition =Cycle (R - R ) / N

N = 8 , 16, 24, 32, 64

M répétitions du Cycle

Temps d’acquisition / image = M*

Page 23: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E
Page 24: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

cycle 1 cycle 2

Acquisition synchronisée avec le signal ECG

Page 25: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

projectionsAcquisition tomographique (SPECT)

Page 26: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

projections

détecteur

Page 27: GAMMA CAMERA (acquisitions). mono-isotope E 1 =140keV(Tc 99m ) ± 10% E1E1 N E

FIN