gas & flame detection solutions - ambetronics · 2019-08-10 · since 1992 manufacturing of :...

8
Since 1992 Manufacturing of : www.ambetronics.com Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters • Oxygen Transmitters • VOC Gas Detectors • Portable Gas Detectors • Dew Point Analyzer • LPG Gas Leak Detection System • Trace Oxygen Analyzer • Bio Gas Analyzer • 3IR/UV Flame Detectors • Wireless Gas Detectors Realtime Remote Alert/Alarm system with data on cloud Services For : • Onsite Calibration Services • Installation and commissioning on site • AMC/ CMC on site Andheri, Mumbai [email protected] [email protected] +91-22-61673000 +91-22-28371143 LPG Storage Tank Commercial Kitchen LPG Gas Bank Underground Car Parking UPS Battery Room Power Plant Pharma Plants

Upload: others

Post on 30-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

Since1992

Manufacturing of :

www.ambetronics.com

Complete Range of

Gas & Flame Detection Solutions

• Toxic & Combustible Gas Transmitters• Oxygen Transmitters• VOC Gas Detectors• Portable Gas Detectors• Dew Point Analyzer• LPG Gas Leak Detection System

• Trace Oxygen Analyzer

• Bio Gas Analyzer

• 3IR/UV Flame Detectors

• Wireless Gas Detectors

Realtime Remote Alert/Alarm system with data on cloud

Services For :

• Onsite Calibration Services

• Installation and commissioning on site• AMC/ CMC on site

Andheri, [email protected]@ambetronics.com

+91-22-61673000+91-22-28371143

LPG Storage Tank

CommercialKitchen

LPG Gas Bank

UndergroundCar Parking

UPSBattery Room

Power Plant

Pharma Plants

Page 2: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

• Pluggable Sensor Module• EC/Catalytic/NDIR/PID

O2SENSOR

AMBETRONICS

O2

SENSOR

Page 3: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

• Redundant Power Supply• Ethernet• SMS Faciality

Multichannel Gas MonitorPanel - 48 Channel

RK - 220 - 48

• 3 Digit LED Display• 20 Segment Bar graph• I/P : 4-20mA• O/P : 4-20mA (Isolated)• 4 Relay O/P (Isolated)• RS-485 O/P (Isolated)• Scada Software

Multichannel Gas Monitor (8CH.)TC-800-WP

• I/P 4-20mA• 2 Common Relay O/P

• Isolated RS-485 O/P

•Addon Relay

• IP-65

Multichannel Gas Monitor (8CH.)TC-800-FLP

ACKPRNMODE

H OL D

Wall MountingMultichannel Gas Monitor (8 CH.)

TC - 800- MS TC - 800- PANEL

UIP-1600-WP

• I/P 4-20mA• 4 Common Relay O/P

• Isolated RS-485 O/P• USB data Logging

• Addon Relays

• IP-65

Multichannel Gas Monitor (16CH.) Multichannel Gas Monitor (16CH.)

UIP-1600-FLP

MULTICHANNEL GAS MONITOR

SETNEXT INCR DEC

AMBETRONICS

MULTICHANNEL GAS MONITORING SYSTEM

HEALTHY

A 1L

A 2L

CH-1 CH-2 CH-8CH-3 CH-4 CH-5 CH-6 CH-7 CH-16CH-9 CH-10 CH-11 CH-12 CH-13 CH-14 CH-15

UIP-1600-WP

CHANNEL PROCESS VALUE

USB

ESCACKHOL D

08 30 00.

Multichannel Gas Monitor (16 CH.)UIP-1600-MS

Multichannel Gas Panel (16 CH.)UIP-1600-Panel

Multichannel Communicator( 80CH.)

MCC-1322-WPMULTICHANNEL COMMUNICATOR

A MB E T RO N I C S

INCRACKSET

SET ACK INCR

MCC-1322-FLP

Multichannel Communicator(80CH.)

Multichannel Communicator(80CH.) Wall Mounting

MCC-1322-MS

Multichannel Gas Monitor (8 CH.) (Wall Mounting)

MCC-1322-Panel

Multichannel Communicator(80CH.) Wall Mounting

• Modbus RS-485 Input• 2 Common Relay• 1 fault Relay• Addon Relay• Isolated RS-485 O/P• IP - 65

• Modbus RS-485 Input• 2 Common Relay• 1 fault Relay• Addon Relay• Isolated RS-485 O/P• Exd IIA/IIB IP - 65

• Modbus RS-485 Input• 2 Common Relay• 1 fault Relay• Addon Relay• Isolated RS-485 O/P

• Modbus RS-485 Input• 2 Common Relay• 1 fault Relay• Addon Relay• Isolated RS-485 O/P

Smart IoT Gateway (48 CH.)

SIG 4GTY-WP SIG 4GTY-FLP SIG 4GTY-MS

Addressable Relay ModuleREL-1200

• 24 VDC Supply I/P

• Specially for Solenoid Valve operation • 2 Relay O/P • Modbus RS-485 I/P

• IP-65

• 3 Digit LED Display• 20 Segment Bar graph• I/P : 4-20mA• O/P : 4-20mA (Isolated)• 4 Relay O/P (Isolated)• RS-485 O/P (Isolated)• Scada Software

• Redundant Power Supply

Multichannel Gas MonitorPanel - 80 Channel

RK - 220 - 80

• Ethernet• SMS Faciality

Multichannel Gas MonitorPanel - 4 Channel

RK - 220 - 4• Conforms with EMC Directive 2004/108 /EEC• Compliance with IEC-60945 Standard for Marine application

Multichannel Gas MonitorPanel - 8 Channel

RK - 220 - 8

Multichannel Gas MonitorPanel - 16 Channel

RK - 220 - 16

* Kindly ask for detail Catalogue and specification of each product

RANGE OF GAS MONITORS & PANELS

3

• I/P 4-20mA• 2 Common Relay O/P

• Isolated RS-485 O/P

•Addon Relay

• Exd IIA/IIB IP-65

• I/P 4-20mA• 2 Common Relay O/P

• Isolated RS-485 O/P

•Addon Relay

• I/P 4-20mA• 2 Common Relay O/P

• Isolated RS-485 O/P

•Addon Relay

• I/P 4-20mA• 4 Common Relay O/P

• Isolated RS-485 O/P• USB data Logging

• Addon Relays

• Exd IIA/IIB IP-65

• I/P 4-20mA• 4 Common Relay O/P

• Isolated RS-485 O/P• USB data Logging

• Addon Relay

• I/P 4-20mA• 4 Common Relay O/P

• Isolated RS-485 O/P• USB data Logging

• Addon Relay

Smart IoT Gateway (48 CH.) Smart IoT Gateway (48 CH.)

• 4 DPDT Relay

• Exd IIA/IIB IP-65

• Isolated RS-485 O/P for SCADA/PLC• MQT T Protocol• 2 Settable Alarm for each channel• SMS & Email Alerts• Ethernet • Wi-Fi

• 4 DPDT Relay• Isolated RS-485 O/P for SCADA/PLC• MQT T Protocol• 2 Settable Alarm for each channel

• Lamp Test facility

Per Channel Per Channel

Complete Panel Size in mm :2300 x 600 x 600 (H) x (W) x (D)

Complete Panel Size in mm :

2200 X 800 X 800(H) X (W) X (D)

es Heightinclud Base Frame also.of 100 mm

MULTICHANNEL GAS MONITOR

CHANNEL PROCESS VALUE

A MB E T RO N I C S

SMART IoT GATEWAY

SETNEXT INCRSHIFT

SIG-4GTY-MS

• Ethernet • Wi-Fi

• 4 DPDT Relay• Isolated RS-485 O/P for SCADA/PLC• MQT T Protocol• 2 Settable Alarm for each channel

Multichannel Gas MonitorPanel - 32 Channel

RK - 220 - 32

• 3 Digit LED Display• 20 Segment Bar graph• I/P : 4-20mA• O/P : 4-20mA (Isolated)• 4 Relay O/P (Isolated)• RS-485 O/P (Isolated)

•Panel Size in mm : 600 x 800 x 400 (W) x (H) x (D)

• 3 Digit LED Display• 20 Segment Bar graph• I/P : 4-20mA• O/P : 4-20mA (Isolated)• 4 Relay O/P (Isolated)• RS-485 O/P (Isolated)

•Panel Size in mm : 600 x 600 x 400 (W) x (H) x (D)

• 3 Digit LED Display• 20 Segment Bar graph• I/P : 4-20mA• O/P : 4-20mA (Isolated)• 4 Relay O/P (Isolated)• RS-485 O/P (Isolated)

•Panel Size in mm : 500 x 500 x 400 (W) x (H) x (D)

• Lamp Test facility

* Product images are only for representation, Actual image and size may differ

• Ethernet WiFi• Lora & Lorawan

• Ethernet WiFi• Lora & Lorawan

Page 4: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

RANGE OF GAS & FLAME DE TECTORS & ANALYZERS

Flame DetectorTesting TorchUV & Triple IR Flame Detector

FL-3311-WP

UV & Triple IR Flame Detector

FL-3311-FLP

UV & Triple IR Flame DetectorFL-3311-FLP-SS

* FLP - Flameproof Enclosure * WP - Weatherproof Enclosure * S - Suction Type * D - Diffusion Type

Portable Single Gas DetectorPG-100-S

PORTABLE GAS DETECTORAMBETRONICS PG-100

Oxygen-0 T0 25.00% V/V

Portable Single Gas DetectorPG-100-D

Dual Channel Gas DetectorPG-200-D

PORTABLE MULTI GAS ANALYZER

PGA-400-POR

PGA-400-POR

Portable Multi Gas Analyzer

• Intrinsically safe• Pluggable Sensor Module• EC/Catalytic/NDIR/PID• Integrated pump• STEL/TWA Alarms• 50,000 log records• > 10 hours backup• USB interface

• EC /NDIR sensor• STEL/TWA Alarms• 50,000 log records• > 10 hours backup• USB interface

• Integrated Pump•Graphical L.C.D. Display• EC/Catalytic/NDIR /PID•Online measurement•STEL, TWA, Alarms•1,00,000 log records•> 8 hours backup• USB interface

• Intrinsically safe• Pluggable Sensor Module• EC/Catalytic/NDIR/PID• STEL / TWA Alarms• 50,000 log records• > 10 hours backup• USB interface

Portable Multi Gas DetectorPG-400-D

Portable Multi Gas Detector

PG-400-S

Portable Multi Gas DetectorPG-800-D

Portable Multi Gas Detector

PG-800-S

•Diffusion typeGraphical L C D display . . . .

•EC/Catalytic/NDIR/PID• STEL/TWA Alarms•1,0 , records0 000•> 8 hours backup• USB interface

•Diffusion typeGraphical L C D display . . . .

•EC/Catalytic/NDIR/PID• STEL/TWA Alarms•1,0 , records0 000•> 8 hours backup• USB interface

•Suction typeGraphical L C D display . . . .

•EC/Catalytic/NDIR/PID• STEL/TWA Alarms•1,0 , records0 000•> 8 hours backup• USB interface

•Suction typeGraphical L C D display . . . .

•EC/Catalytic/NDIR/PID• STEL/TWA Alarms•1,0 , records0 000•> 8 hours backup• USB interface

Portable Biogas Analyser

BIO-400-S-POR

BIO-400-S-POR

Biogas Analyser- Rack MountBIO-400-S-RAK

BIO-400-S-RAK

Biogas Analyser - Panel MountBIO-400-S-PANEL

BIO-400-S-PANEL

BIOGAS ANALYSER

Portable Biogas Analyzer

PG-400-PEL• Handheld type• 128 x 64, Graphic L.C.D. display with backlight• C CH O4 2 2 2, , O , H S Detection

Optional 1,0 , logging0 000 records

Event logging USB interface Li-po rechargeable Battery

• Special Suitcase casing• 128 x 64, Graphic L.C.D. display & backlight• Event logging

• C CH O4 2 2 2, , O , H S DetectionOptional 1,0 , logging records0 000

• •USB interface Li-po rechargeable Battery

• Rack mounting type• 128 x 64, Graphic L.C.D. display & backlight• Event logging

• C CH O4 2 2 2, , O , H S DetectionOptional 1,0 , logging records0 000

• • USB interface Li-po rechargeable Battery

• Panel type housing• 128 x 64, Graphic L.C.D. display & backlight• Event logging• USB interface

• C CH O4 2 2 2, , O , H S DetectionOptional 1,0 , logging records0 000

Li-po rechargeable Battery

4

OGA - 3500-PPM

Trace Oxygen Analyzer

DP-600

DIFFUSION MODE

SENSOR

• Max 2 meter length for Diffusion mode Sensor

OGA - 3500-PPM

Trace Oxygen AnalyzerOGA - 3500-VOL

Percent Oxygen Analyzer Dew Point Monitor

GA-3500-PM-O2

Headspace Oxygen AnalyzerPG-400

Portable Dew Point Indicator

PG-100-DEW

Smart Gas Analyzer - Oxygen

Particulate

SamplingProbe

Foam seal pads ,septa - sticky nickel

Needle

OXYGEN ANALYZER

GA-3500-PM-O2AMBETRONICS

SETNEXT SHIFT

INCR

A 1L A 2L HTY PRG CAL KEY TX RX

OXYGEN ANALYZER

GA-3500-PM-O2AMBETRONICS

SETNEXT SHIFT

INCR

A 1L A 2L HTY PRG CAL KEY TX RX

OXYGEN ANALYZER

GA-3511-PM-O2AMBETRONICS

SETNEXT SHIFT

INCR

A 1L A 2L HTY PRG CAL KEY TX RX

Smart Gas Analyzer - Oxygen

GA-3511-PM-O2

AMBETRONICS

Model No : PG-400

O : 0 to 100% V/V2

ALM USBCHG

ACK INCR

H O AEADSPACE XYGEN NALYZER

SET• Built in O Sensor2

• 4 -20mA O/P• 3 Relay O/P• RS-485 O/P• IP 54• Panel Mounted

• 2 Line L.E.D. Display • Detects Oxygen with high accuracy• 128 x 64 mm Graphic

L.C.D. display • Alarms with Audio & Visual alerts • In-built audio buzzer & Vibrator • One year of warranted support

• . . .L C D display with backlightAmbient monitoring50000 records & visiblein ASCII format

• Low BAT indicationwith Buzzer

• rechargeable battery

200 PPM & 2000 PPM Range Selectable•10,000 PPM Range available• In-built Sensor• N application2

• Built in O Sensor2

• 4 -20mA O/P• 3 Relay O/P• RS-485 O/P• IP 54• Panel Mounted

• 8 x 2 L.C.D. Display

• 3IR & UV Detection• Fast response < 3 sec. • 3 Relay O/P • 4mA & 20mA O/P• BLE, RS-485 or HART configurable• IP-65

• 3IR & UV Detection• Fast response < 3 sec. • 3 Relay O/P • 4mA & 20mA O/P• BLE, RS-485 or HART configurable• Exd IIC T6 IP-66

• 3IR & UV Detection• Fast response < 3 sec. • 3 Relay O/P • 4mA & 20mA O/P• BLE, RS-485 or HART configurable• Exd IIC T6 IP-66• SS Enclosure

10% V/V & 30% V/V Range Selectable•100% V/V Range available• In-built Sensor

Dew Point : -100°C to 60°C•Moisture : 0 to 10,000 PPM• Range Selectable

IS/IEC 60079

Part 11L-7800047118

IS/IEC 60079

Part 11L-7800047118

Page 5: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

RANGE OF CLEAN ROOM GAS MONITORS

5

Stand

Canopy

AEPL-CANOPY

Stand/Canopy Floor MountingAEPL-FMTS

Transmitter Calibration GasesOxygen/Toxic / Combustible

AEPL-CG-3/CG-0.5

• Gas Cylinder• Regulator• Flowmeter• Calibration Cap• Tubing

Detector Mounting Plate

AEPL-MP

Weatherproof Junction BoxJB-204-WP

• Input : 4 No. Cable Gland•Output : 4 No. Cable Gland

• 24V, GND, O/P, D+, D- connections (6 core)• Flameproof enclosure available

JB-308-WPWeatherproof Junction Box

• 24V, GND, O/P, D+, D- connections (4 core)• Flameproof enclosure available

Weatherproof Junction BoxJB-400-WP

• 4 No. Transmitter I/P & O/P connection• 24V, GND, O/P, D+, D- Signals connections(6core)

• ‘Normally open’ Relay contact connectivity• Inbuilt DPDT Relay for Hooter connection.

Flameproof Junction Box

HCF/JB/FLP/2C

FLAMEPROOFHOOTER CUM FLASHER

JB-500-FLP

• One Transmitter I/P & O/P connection• 24V, GND, O/P, D+, D- Signals

• Weatherproof enclosure available

Flameproof Junction BoxJB-400-FLP

• 4 No. Transmitter I/P & O/P connection• 24V, GND, O/P, D+, D- Signal connections• ‘No’ Relay contact connectivity• Inbuilt DPDT Relay for Hooter connection• Exd IIA/IIB IP-65

• 1” Red L.E.D. display• Integrated Buzzer• 2 Nos. DPDT Relay• Isolated RS-485 Modbus RTU

CRM-131-2

Clean Room Monitor forCombustible Gases

CRM-131-3

Clean Room Monitor forCombustible Gas & Humidity Indication

CRM-232-23-I/R

Clean Room Monitor forOxygen & Temperature Detection

CRM-485-11

Clean Room Process MonitorClean Room Monitor forOxygen & Toxic Gases

Clean Room Monitor forCombustible Gases

CRM-111-3CRM-111-2

Clean Room Monitorfor (NDIR) CH4

CRM-111-4

• Integrated Buzzer• 2 Nos. SPDT Relay• Isolated RS-485 with Modbus RTU• 4-20mA Output

• Integrated Buzzer• 2 Nos. SPDT Relay• Isolated RS-485 with Modbus RTU

• Integrated Buzzer• 2 Nos. SPDT Relay• Isolated RS-485 with Modbus RTU• 4-20mA Output

• 1” Red L.E.D. display• Integrated Buzzer• 2 Nos. DPDT Relay• Isolated RS-485 Modbus RTU

• 1” Red L.E.D. display• Integrated or Remote Humidity sensor• Integrated Buzzer• 2 Nos. DPDT Relay• Isolated RS-485 Modbus RTU

CRM-232-22-I/R• 1” Red L.E.D. display• Integrated or Remote Temperature sensor• Integrated Buzzer• 2 Nos. DPDT Relay• Isolated RS-485 Modbus RTU

Clean Room Monitor forOxygen & Toxic Gases

RANGE OF ACCESSORIES

FLP Hooter-cum-FlasherHCF-FLP-IIC

M20

• Input : 8 No. Cable Gland•Output : 8 No. Cable Gland

Hooter-cum-Flasher

M20 M20

HOOTER CUMFLASHER

AFOR LARM FLASHER AFOR LARM

RED GREEN

AMBER

•24 VDC Supply

HCF/JB/FLP/2C

FLAMEPROOFHOOTER CUM FLASHER

HCF-FLP-RH-GA

•24 VDC Supply

M20 M20

HOOTER CUMFLASHER

AFOR LARM

HOOTER CUMFLASHER

AFOR LARM

RED GREEN

HCF/JB/FLP/2C

FLAMEPROOFHOOTER CUM FLASHER

HCF-FLP-RH-GH

Hooter-cum-Flasher

• Red/Green/Amber Flasher• 95 / 100 dB• ¾” ET Connection• 24 VDC Supply

WeatherproofBuzzer cum Flasher

HCF-WP-RH

* Kindly ask for detail Catalogue and specification of each product

• HCF-FLP-IIC-RH (Red Flasher)• HCF-FLP-IIC-GH (Green Flasher)• HCF-FLP-IIC-AH (Amber Flasher)•24VDC I/P & IP-66

Magnetic WandMW-001CG/ST

Sampling ProbeDouble Compression CableGland / Stopper

• Upto 2000 mm long length available• Inbuilt with temperature detection available• Hose pipe available as per gas type• Moisture filter connection

Hooter-cum-Flasher

•Vertical Mounting•Dimension: 96 X 96 mm• I/P Voltage: 24VDC/ 230VAC• Flasher Housing: Acrylonitrile Butadiene Styrene• Audible Range: 100 dB

•For programming ofFlameproof Gas Detectors

M-20CG/FLP/2C

FLA-104

StopperSP/FLP/2C

PG-SPHCF-WP-T

AL1

CLEAN ROOM PROCESS MONITOR

CRM-485-11

A 2L

COM

• Integrated Buzzer• 2 Nos. SPDT Relay• Isolated RS-485 with Modbus RTU Input & Output

Page 6: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

Internet of Things - Comprehensive Solutionfor Smart Indication & Control Unit

ETHERNE T RS RS/ -485/ -232• MODBUS RTU• MODBUS TCP-IP• MODBUS Over TCP-IP

• SCADA, E.R.P.• PLC

Solar Powered

HEALTHY AL AL1/ 2 COMM

SMS Alerts

Alarm FormatSMSOK SMS Format

SMSSMS

Wireless Gas Detector-1

2MSPWGD

SIG Receiver

HEALTHY AL AL1/ 2 COMMHEALTHY AL AL1/ 2 COMM

Wireless Gas Detector-2

2MSBWGD

Wireless Gas Detector-3

2MSP-WPWGD

Wireless Gas Detector-4

2MSS-WPWGD

SIG2RCV-WP

Hydrogen Gas Detection Systemfor Battery Room With SMS Facility

Ventilation FanHooter Cum Flasher

230 VACMains Supply Magnetic

Wand forProgramming

M20

0000 LEL%HC

MagneticWand for

Programming

M20

0000 LEL%HC

SIM

HE ALTH Y FA ULT/

NET W ORK

GS M ON

COM P ORT

S MA RT M ODULE I oT

AMBETRONICS

SIM2G485N

SMS Alerts

MQT T Broker

ACKPRNMODE

HOLD

MagneticWand for

Programming

M20

0000 LEL%HC

RS-485(MODBUS RTU)

Gas CollectionCone

CH:01 (Detector-1 )ST : AL-1:HIGHPV : +25% LELTM : 04/05/19 15:50LOC : Gate-1UID : SIG760389RSSI : -83

CH:01 (Detector-1 )ST : OKPV : +0% LELTM : 04/05/19 15:55LOC : Gate-1UID : SIG760389RSSI : -83

WGD2MSS-FLPST : AL-2:HIGHGC : 49 %LELAL2: 30%LELBT : 100%TM : 18:27DT : 14 FEB 19UID : 919191LOC :MUM-ANDIRSSI: -053

ST : OKGC : 0 %LELBT : 100%TM : 18:19DT : 14 FEB 19UID : 919191LOC :MUM-ANDIRSSI: -055

Ventilation Fan

GT-1000-WPGT-1000-WP

Ventilation Fan Carbon Monoxide Detection System for Under Ground Car parking Area

Emergency Light

GT-4000-FLP

LPG GAS DETECTOR

AMBETRONICS

DECINCR FLT PRG TESTA 1L

SIM

HEALTH Y FAULT/

NETWORK

GSM ON

COM PORT

SMA RT MODULE IoT

AMBETRONICS

SIM2G485S

SIM2G485S

SMS Alerts

APPLICATION EXAMPLES

(TC-800-MS)

Buzzercum

Flasher

230VACMains Supply

( 3 Wire : 24V ,GND, O/P)

Detector -1 Detector -7 Detector -8

Connectivity to Relay 2

Connectivity to Relay 1

RS-485MODBUS RTU

( 2 Wire: 24V, O/P) ( 2 Wire: 24V, O/P)

SIM2G485N

Page 7: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

APPLICATION EXAMPLESLPG/PNG Gas Leakage Conventional System

SMS Alerts

RS-485MODBUS RTU

240VACMains Supply

GT-4000-FLP

3 Core Cable

3 Core Cable(24VDC, GND, 4-20mA O/P)

3 Core Cable (24VDC, GND, 4-20mA O/P)

GT-4000-FLP

GT-4000-FLP

SMARTGAS TRANSMITTER

AMBETRONICSAMBETRONICSAMBETRONICS

FLT PRG TEST

GT-4000-FLP

GT-4220-FLP-S

Solenoid Valve

Relay Module(REL-1200)

Flasher

AMBETRONICSAMBETRONICSAMBETRONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100.0%LEL

B UZ Z

GT-4220SMART GAS TRANSMITTER

GT-4220-FLP-S

SMS Alerts

RS-485MODBUS RTU

230VACMains Supply

LPG/PNG Gas Leakage Addressable System

M-25

UIP-800-PMH

Smart Gas TransmitterWGD2MSP-FLP

M20

Upto 48 MODBUS Slaves / AddressSTH-200-FLPWGD2MSP -WP

MQT T Client

SIM

HEALTHY FAULT/

N ET W OR K

GSM O N

CO M PO RT

SMART MO DULE Io T

AMBETRONICS

SIMWF485

MQT TDash board

MQT T BrokerYour server cloud

ambeiot.com

CLOUD MQT T

Upto 48 MODBUS Slaves / Address

•SMS•E-mail

Router/Dongle/Hot Spot

Wi-Fi

SIM

HEALTHY F AULT/

NETWORK

GSM ON

COM PORT

SMART MODULE IoT

AMBETRONICS

SIM2G485S

Smart IoT Module Series

7

SIMWF485

SIM2G485S

HEALTHY AL AL1/ 2 COMM

SMARTGAS TRANSMITTER

AMBETRONICSAMBETRONICSAMBETRONICS

FLT PRG TEST

SMARTGAS TRANSMITTER

AMBETRONICSAMBETRONICSAMBETRONICS

FLT PRG TEST

SMARTGAS TRANSMITTER

AMBETRONICSAMBETRONICSAMBETRONICS

FLT PRG TEST

GT-4000-FLP

Flasher

SIM2G485

AMBETRONICSAMBETRONICSAMBETRONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100.0%LEL

B UZ Z

GT-4220SMART GAS TRANSMITTER

AMBETRONICSAMBETRONICSAMBETRONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100.0%LEL

B UZ Z

GT-4220SMART GAS TRANSMITTER

4 Core Cable(24VDC, GND, D+, D-)

GT-4220-FLP-S

SIM

HEALTHY FAULT/

NETWORK

GSM ON

COM PORT

SMART MODULE IoT

AMBETRONICS

SIM2G485S

Danger Alarm-2Warning Alarm-1

Fault Alarm

MCC-1322-MSGT-4220-FLP-S

AMBETRONICSAMBETRONICSAMBETRONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100.0%LEL

B UZ Z

GT-4220SMART GAS TRANSMITTER

Page 8: Gas & Flame Detection Solutions - Ambetronics · 2019-08-10 · Since 1992 Manufacturing of : Complete Range of Gas & Flame Detection Solutions • Toxic & Combustible Gas Transmitters

ILLUSTRATIONS

230VACMains Supply

8 C - WEATHER - -800-HANNEL GAS MONITORING SYSTEM PROOF TC WP

Alarm / Hooterwith Flasher

RS-485 to USBConverter

MAX 1000 ME TER

Weatherproof Hooter cum

FlasherFlameproof

Hooter

OR

16 x 4-20mA IsolatedRetransmission output

for PLC/DCS/Recorder

Intelligent Modem

RS-232 toUSB Converter

Alarm Alerts onMobile/E-mail

RS-485 toUSB Converter

230VACMains Supply SMARTLOG Software /

SCADA Software2/3 wire transmitter with 4-20mA O/P

8x3 core cablemax 1000 meter

17-B, Tarun Industrial Estate, Mogra Pada, New Nagardas Road, Andheri (E.) Mumbai - 400 069, India.Mob.: 9320619646 • 9320621646 • Tel.: +91-22-61673000, 28371143 • Fax : +91-22-28226570E-mail : [email protected][email protected] • Web : www.ambetronics.com

ISO 9001:2015 CertifiedPESO

Version : GAS COMMCAT-R8-01072019

8 C - FLAME - -800-FLHANNEL GAS MONITORING SYSTEM PROOF TC P

Alarm / Hooterwith Flasher

RS-485 to USBConverter

230VACMains Supply

230VACMains Supply

GD3 GD8

Zone-1

RS-485

230VACMains Supply

Buzzer cumFlasher

Zone Panel-1( MCC-1322-MS)

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

G 2D

AMBETRONICSAMBETRONICSAMBETRONICS

A 1L A 2L FLT COM

LPG : 0 .0 - 100.0%LEL

B UZ Z

GT-4220SMART GAS TRANS MI TT ER

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

GT-4220-FLPG 1D

RS-4854 core cable

(24VDC, GND, D+, D-)

Solenoid Valve

Buzzer cum Flasher

Relay Module(REL-1200)

GD3 GD8

Zone-2

RS-485

230VACMains Supply

Buzzer cumFlasher

Zone Panel-1( MCC-1322-MS)

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

G 2D

AMBETRONICSAMBETRONICSAMBETRONICS

A 1L A 2L FLT COM

LPG : 0 .0 - 100.0%LEL

B UZ Z

GT-4220SMART GAS TRANS MI TT ER

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

GT-4220-FLP

G 1D

RS-4854 core cable

(24VDC, GND, D+, D-)

Solenoid Valve

Buzzer cum Flasher

Relay Module(REL-1200)

GD3 GD16

Zone-3

RS-485

230VACMains Supply

Buzzer cumFlasher

Zone Panel-1( MCC-1322-MS)

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

G 2D

AMBETRONICSAMBETRONICSAMBETRONICS

A 1L A 2L FLT COM

LPG : 0 .0 - 100.0%LEL

B UZ Z

GT-4220SMART GAS TRANS MI TT ER

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

AMB ET RONICSAMB ET RONICSAMB ET RONICS

A 1L A 2L FLT COM

LPG : 0.0 - 100 .0%LEL

B UZ Z

GT-4220SMART GAS TRANSMIT TER

GT-4220-FLPG 1D

RS-4854 core cable

(24VDC, GND, D+, D-)

Solenoid Valve

Buzzer cum Flasher

Relay Module(REL-1200)

RemoteControl Room

ORPLC/DCS Panel

230VACMains Supply

OR

Option-2

Option-3

Main Control Room

RS-485MODBUS RTU

Smart IoT Module (SIM)

SIM

HEALTHY/FAULT

NETWORK

GSM ON

COM PORT

SMART IoT MODULE

AMBETRONICS

SIM2G485

SIM

HE ALTHY/FAULT

NET WORK

GSM ON

COM PORT

SMART IoT M ODULE

AMBETRONICS

SIM2G485

www.ambeiiot.com Cloud

A LPG G D SDDRESSABLE AS ETECTION YSTEM

230VACMains Supply Buzzer cum

Flasher

Zone Panel-1( MCC-1322-MS)

JB-400-WP

230VACMains Supply Buzzer cum

Flasher

Zone Panel-1( MCC-1322-MS-R)

Option-1Repeater Panel Hooter cum

Flasher

Danger Alarm

Fault Alarm

Warning Alarm

RS-485MODBUS RTU

GT-4220-FLP

MAX 1000 METERMAX 1000 METER

SMARTLOG SOFTWARE/SCADA SOFTWARE

Flameproof Gas Detector4 Core CableRS-485 O/P

Hooter cumFlasherHooter cum

Flasher

RS-485, for SCADA Software

(Optional)RS-485,

Modbus RTU1000 Meter Length

FlameproofJunction Box

WeatherproofJunction Box

4 Core cable(1) 24VDC (2) GND(3) TX (4) RX

Weatherproof Gas Detector