Gas Quality Reconstruction
@ E.ON Gastransport
SIMONE Congress 2008, Dubrovnik
Jörg Bödeker, Dr. Dietrich Weise
2Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
E.ON Gastransport GmbH
Germany's leading gas transmission company
founded in 2004 as a subsidiary of E.ON Ruhrgas AG
legal ownership of pipeline system since 2008
actually approx. 280 employees
3Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
total length: 11.600 km
compressor stations: 28
compressor power: 900 MW
>1000 exit points
>100 gas quality measurements
High Pressure Pipeline System
underground storage facility
compressor station
Bocholt
Berlin
Aachen Cologne
Koblenz
Trier
Saarbrücken
Frankfurt
Würzburg
ZwickauGießen
Winterberg
Bielefeld
Hanover
Emsbüren
Meppen
BremenBremerhaven
Hamburg
Lübeck
Flensburg
Bamberg
Nuremberg
RegensburgKarlsruhe
Munich
Stuttgart
Freiburg
Essen
field station
gas import point
4Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Use of SIMONE at E.ON Gastransport
Linux (Dispatching System)
Online reconstruction (PRSIM)
Cyclic look-ahead simulation (ZYSIM)
Compressor fuel consumption optimization (ZYKOPT…)
Test calculations (VOSIM…)
Windows
Capacity determination
Network planning
5Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Gas Quality Tracking Systems:
Regulatory requirements in Germany
authority permission by the boards of weights and measures
technical approval by the national metrology institute (PTB)
complete system is treated like a gauged measurement device
verified measurement instruments for input values, e.g.:
1% for volume measurement
1% for superior calorific value measurement
0,5% for normal density measurement
6Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Validation of Gas Quality Tracking Results
reference measurement points at critical line sections(e.g. blending or transition zones)
use of approved process gas chromatographs (12 components)
validation is based on daily average values for:
Superior calorific value Hs: 1%
Gas law deviation factor K: 0,8% at 100 bar and 0°C, AGA-8 (K is dependant on the gas composition, K = Z/Zn)
Normal density n: 0,5%
7Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Features of the Reconstruction System
One network model for dispatching and reconstruction
Input data from two independant systems(dispatching and data retrieval system)
Calculation in 3 minute time steps (important for mixing stations)
Calculation of calorific value, normal density and gas compositionfor each exit point in hourly and daily granularity
Approval for daily average values
Automatic hourly reconstruction calculation with time offset (6 hours)
Preliminary daily values (D+1)
Final daily values for billing purposes (2nd day M+1)
8Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Typical Calorific Values
Low Calorific Gas(L-Gas Market Area)
9,6 .. 10,3 kWh/m³(34,5 .. 37 MJ/m³)
High Calorific Gas(H-Gas Market Area)
11,1 .. 11,8 kWh/m³(40 .. 42,5 MJ/m³)
August 2008
9Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Network representation in SIMONE
More than…
8000 nodes
1000 exit points
50 supply nodes
5900 pipes
2900 valves
200 control valves
Relevant area (red) in current project:
200 offtake nodes
12 reference points
10Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Example for a reference point
11Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Example for a reference point – simplified view
Gas qualityreference
60
30
0..50relative normal density:
approx. 0,64superior calorific value:
approx. 9,65 kWh/m³
relative normal density:approx. 0,62superior calorific value:approx. 9,75 kWh/m³
exit point
30..80
quantities in 10³ m³/h
exit quantity values over 2 weeks
12Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Night
Example for a reference point, different flow situations
Gas qualityreference
mediumofftake
Gas qualityreference
highofftake
Day
Gas qualityreference
lowofftake
Sunday
13Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Reference point: Superior calorific value Hs
results for one month, absolute daily values
14Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Reference point: Superior calorific value Hs
results for one month, relative deviation
15Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Reference point: Gas law deviation factor K
results for one month, absolute daily values
16Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Reference point: Gas law deviation factor K
results for one month, relative deviation
17Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Reference point: Normal density n
results for one month, absolute daily values
18Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Reference point: Normal density n
results for one month, relative deviation
19Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Overview functionality for result and input data survey
in the gas quality reconstruction system
problem: large amount of data
solution: hierarchical data model & aggregated status information
existing hierarchical data model in the dispatching system:1. type of value 2. network 3. station 4. group 5. unit 6. equipment 7. signal
20Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Hierarchical Overview
(used for input data and calculation results)
21Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Hierarchical Overview – filtered view
(used for input data and calculation results)
22Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Special time variation curves / tables
(used for input data and calculation results)
23Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
Conclusion
experts are essential for routine operations and maintenance
processing time very long – 8 hours for one month
(2 hours calculation + 6 hours data transfer via SIMONE API)
results of tracking system improve and simplify
billing operation and balancing
reduced investment in additional gas quality measurement
instruments
new data analysis features help to improve overall quality
(network model and data)
24Gas Quality Reconstruction at E.ON Gastransport [SIMONE Congress 2008] Jörg Bödeker, Dr. Dietrich Weise
E.ON Gastransport GmbH
Thank you for your attention.
For further information:
E.ON Gastransport GmbHKallenbergstr. 5D-45141 Essen
Jörg Bö[email protected]: +49 (201) 27 87 – 24 26
Dr. Dietrich [email protected]: +49 (201) 184 – 50 34
www.eon-gastransport.com