Følgeseddel 82842 Room reference Suspension type Delivery Note 50 mm LS* O* Ø* O* H* W* O* H* W* Inlet option B Inlet option A Inlet option C *See further sizing details on enclosed project drawings, if any, and also see deli- very note (packing list) and read off position description. 50 mm LS* 50 mm LS* Alu-rails labelled with a saw symbol do not require further trimming. Please find Information on delivery and installa- tion in the box labelled INFO. L = Length of duct LS = Length of socket O = Offset W = Width Ø = Inlet diameter H = Height D = Interior duct diameter A = Distance socket 1 B = Distance socket 2 max 500 mm max 2000 mm L* A* B* Ø* LS* max 500 mm 50 mm 20 mm D* D* Expansion bolt------------------ Connector------------------------ M6 thread bar------------------- (std. 1 metre) Check nut------------------------ Alu-suspension section--- SafeJoint (200 mm)--------------------- Screw------------------------ Spacing profile-- SafeTrack---------- End section KE-------- #Office 1 ---------- ---------- D-SafeTrack system 2 54 mm D-SafeTrack (exp. bolt) General rules 0980013-GB

Upload: ke-fibertec

Post on 30-Mar-2016

214 views

Category:

Documents


0 download

DESCRIPTION

*See further sizing details on enclosed project drawings, if any, and also see deli- very note (packing list) and read off position description. Please find Information on delivery and installa- tion in the box labelled INFO. KE-------- #Office 1 ---------- ---------- D-SafeTrack system 2 Check nut------------------------ Alu-suspension section--- SafeJoint (200 mm)--------------------- Screw------------------------ Spacing profile-- Delivery Note Room reference 82842 Suspension type D * LS *

TRANSCRIPT

Page 1: GB-0980013-web

Følgeseddel

82842

Room reference

Suspension type

Delivery Note

50mm

LS*

O*

Ø*

O*

H*W*

O*

H*W*

Inlet option BInlet option A Inlet option C

*See further sizing details on enclosed project drawings, if any, and also see deli-very note (packing list) and read off position description.

50mm

LS*50mm LS*

Alu-rails labelled with a saw symbol do not require further trimming.

Please find Information on delivery and installa-tion in the box labelled INFO.

L = Length of ductLS = Length of socketO = OffsetW = WidthØ = Inlet diameterH = HeightD = Interior duct diameterA = Distance socket 1B = Distance socket 2

max 500 mm

max 2000 mm

L*

A*

B*

Ø*

LS*

max 500 mm

50mm20mm

D*

D*

Expansion bolt------------------

Connector------------------------

M6 thread bar------------------- (std. 1 metre)

Check nut------------------------Alu-suspension section---SafeJoint (200 mm)---------------------Screw------------------------Spacing profile--

SafeTrack----------

End section

KE--------#Office 1--------------------D-SafeTrack system 2

54mm

D-SafeTrack (exp. bolt)General rules

0980013-GB

Page 2: GB-0980013-web

7The 4 SafeLock expansion screws replace the former tightening cords. The SafeLock is inserted into the “keyhole” at the end of the SafeTrack and is tightened with a screwdriver (max. 5 rotations). It is important to fully insert the screw before tightening.

3End sections are to be mounted to rail ends (must be prior to mounting duct).

4KE Interior System is fed from box into rails (so as to keep duct clean!)...

5...and is pulled out at the same time.

6Mounting of clamp.Inlet sockets in duct roof areaccessed viazippers.

A*

1Supports and spacing profiles are mounted on the ceiling; positioned in accordance to the location of inlet socket, duct start or duct bot-tom.

2Rails are clicked into holders (click/rotation is in one direction ONLY).

January 2012