ge circuit breakers and disconnects thermal-magnetic ... · a complete circuit breaker consists of...
TRANSCRIPT
GE Circuit Breakers and Disconnects
Note: All UL listed as HACRtype except 10 amp
Types TEB, TED,THED—Noninterchangeable Trip
Thermal-Magnetic Molded-Case Circuit BreakersbO°C/75°C Conduttoi 10-150 Amperes
Rating! hi ough lOOAmpeies, 120-600 Volts AC75°C Above 100 Amperes 125, 250 Volts DC
Single-Pole—Includes Cu/AI load lugs only. If linelugs are required, add suffix "WL" to Catalog Number.
One-Pole Two-Pole Three-Pole
AmpereRating
1 01 52025303540455060
708090
100
100NA
Type TEB
120 Vac125 Vdc
Catalog Number
T E B 1 1 1 0 1 0 ®T E B 1 1 1 0 1 5 ©TEB111020®TEB111025TEBI 1 1 0 3 0TEB1 11035T E B 1 1 1 0 4 0TEB111045TEB111050TEB111060
TEB1I1070TEB1 11080TEB111090T E B 1 1 1 1 0 0
TEB111Y100®®
ListPrice,
GO-135B
$ 78.5078.5078.5078.5078.5078.5078.5078.5078.5078.50
13400134.00134.00134.00
65.50
Type TED
277 Vac125 Vdc
Catalog Number
TED1 1 3 0 1 0 ®TED1 13015®TED1 13020®TED1 13025TED1 13030TED1 13035TED1 13040TED1 13045TED1 13050TED1 13060
TED1 13070TED1 13080TEDI 1 3090TED113100
TED113Y100®®
ListPrice,
GO-135B
$ 82.5082.508250825082.5082.5082.5082.5082.5082.50
159.00159.00159.00159.00
82.50
347 Volts AC®Catalog Number
TED1 14015TED1 14020TED1 14025TED1 14030
_————__——
—
ListPrice,
GO-1358
$152.00152.0015200152.00
_————_———
-
Type THED
347 Volts ACCatalog Number
THED114015®THFD1 14020®THED1 14025THED1 14030
—————_———
-
ListPrice,
GO-135B
$416.00416.00416.00416.00
_————__——
-
Two-Pole—Includes Cu/AI Line and Load Lugs.
AmpereRating
101 52025303540455060
708090
100
100NA150NA
Type TEB
240 Vac, 250 VdcCatalog Number
TEB122010WL®TEB122015WLTEB1220?OWLTEB122025WLTEB1P2030WLrEB122035WLTEB122040WLTEB122045WLTEBI22050WLTEB122060WL
TEB122070WLTtB122080WLTEB122090WLTEB122100WL
TEB122Y100®
ListPrice,
GO-135B
$159.00159.00159.00159.00159.00159.00159.00159.00159.00159.00
261 00261 00261.00261.00
15900
Type TED
480 Vac 250 VdcCatalog Number
TED124010WL®TED 1 2401 5WLTED124020WLTED124025WLTED124030WLTED124035WLTED124040WLTED124045WLTED124050WLTED124060WL
TED124070WLTED124080WLTED124090WLTED124100WL
TED124Y100®TED124Y1500®
ListPrice,
GO-135B
$290.00290.00290.00290.00290.00290.00290.00290.00290.00290.00
377.00377.00377.00377.00
2630070800
Type THED Hi Break ®
480 Vac 250 VdcCatalog Number
THED124015WLTHED124020WLTHED124025WLTHED124030WLTHED124035WLTHED124040WLTHED124045WLTHED124050WLTHED124060WL
THED124070WLTHED124080WLFHED124090WLTHFD124100WL
-
ListPrice,
GO-135B
$560.00560.00560.00560.00560.00560.00560.00560.00560.00
6530065300653.00653.00
-
Three-Pole—Includes Cu/AI Line and Load Lugs.
AmpereRating
101 52025303540455060
708090
100
1 1 0125150
100NA150NA
Type TEB
240 Volts ACCatalog Number
TEB1 3201 OWL®TEB132015WLTEB132020WLTEB132025WLTEB132030WLTEB132035WLTEB132040WLTEB132045WLTEB132050WLTEB132060WL
TEB132070VVLTEB132080WLTEB132090WLTEB132100WL
—
TEB132Y100®
ListPrice,
GO-135B
$240.002400024000240.00240.00240.00240.0024000240.00240.00
339.00339.00339.00339.00
—
240.00
Type TED
480 Volts ACCatalog Number
TED134010WL®TED134015WLTED134020WLTED134025WLTED134030WLTED134035WLTED134040WLTED134045WLTED134050WLTED134060WL
TED134070WLTEDI34080WLTED134090WLTED134100WL
TED1 3 4 1 1 OWLTED134125WLTED134150WL
TED134YT100®TED134YT150®
ListPrice,
GO-135B
$ 377.00377.00377.00377.00377.00377.00377.00377.00377.00377.00
445.00445.00445.00445.00
1198.001198.001198.00
377.00967.00
Type TED ] Type THED Hi Break
600 Volts ACCatalog Number
TED136015WLTED136020WLTED136025WLTED136030WLTED136035WLTED136040WLTED136045WLTED136050WLTED136060WL
TED136070WLTED136080WLTED136090WLTED136100WL
TED136110WLTED136125WLTED136150WL
TED136YT100®TED136YT150®
ListPrice,
GO-135B
$ 439.00439.00439.00439.00439.00439.00439.00439.00439.00
534.00534.005340053400
1188.001198.001198.00
445.00967.00
480 Volts ACCatalog Number
-
-
THED134110WLTHED134125WLTHED134150WL
—
600 Volts ACCatalog Number
THED136015WLTHED136020WLTHED136025WLTHED136030WLTHED136035WLTHED136040WLTHED136045WLTHED136050WLTHED136060WL
THED136070WLTHED136080WLTHED136090WLTHED 1 361 OOWL
THED136110WLTHED136125WLTHED136150WL
-
ListPrice,
GO-135B
$ 655.00655.00655.00655.00655.00655.00655.00655.0065500
742.00742.00742.00742.00
1683001683.001683.00
—
ffi Single-pole, 15- and 20-ampbreakers are also UL listed asswitching-duty breakers,suitable for switching 120 voltsac (TEB), 277 volts ac (TED,THED) fluorescent lightingloads
Suitable for 10kAIC at 480 Vac,but not labelled or UL listedMolded-case switch Internalaccessory installation requiresfactory installed dummy tripspecify on order Accessoriesnot available for one-pole TEB,TED See page 16-23
® Two-pole breaker is furnishedin three pole case
© Molded-case switch includesline and load lugs
® Includes factory installeddummy trip
Accessories:See pages 16-19 to 16-32
Prices and data subject to change without notice 1999 Issue 16-7
Gf Circuit Breakers and Disconnects
Section 16
Spectra RMS™ Molded Case Circuit BreakersFeaturesSE150, SF250, SG600 and SK1200 circuit breaker frames have adigital solid state, rms sensing trip system with field installable,front-mounted rating plugs to establish or change the breakerampere rating Adjustable instantaneous with tracking short-timeis standard on all frames including SE150
A complete circuit breaker consists of a UL listed circuit breakerframe and a rating plug (UL listed interchangeable trip unit)Terminal lugs for cable connection are available if required
• All frames use the same UL listed field-installable internalaccessories (auxiliary switch shunt trip undervoltage release,and bell alarm)
• All frame sizes have maximum UL listed interrupting ratings of200 kA @ 240 volts ac and 100 kA @ 480 volts ac with 600 voltsac ratings to 65 kA depending on frame size UL listed currentlimiting versions are provided through the SG600 frame for the65 kA @ 480 volts ac and the 100 kA @ 480 volts ac modelswith no increase in physical frame size
• Spectra RMS Mag-Break* instantaneous-only motor circuitprotectors also use the same digital, solid-state trip unit andrating plugs as the circuit breakers The interchangeable ratingplug establishes the instantaneous pickup range (with trackingshort-time) but does not change the frame ampere rating
• Spectra RMS molded case switches have a fixed, high-setinstantaneous trip (without tracking short-time function) andhave short circuit withstand ratings equal to their equivalentbreaker frame size interrupting rating in most cases
• Spectra RMS breakers are ambient insensitive Trip times will notvary over the range 10-50°C breaker ambient Refer to GET-7002for further application information
• Spectra RMS breakers contain no parts that would supportfungus growth and are therefore inherently fungusproof
Other MCCB Features• Broad product line to meet virtually any application need• Reduced downtime A tripped breaker is easily spotted and can
be immediately reset after the fault has been corrected• Eliminates single phasing A common trip bar disconnects all
poles simultaneously on both overloads and short circuits• Offers application flexibility through the use of a wide variety of
accessory devices and special attachments• Repetitive operation—no fuses to replace• Breakers can be repetitively tested Fuses must be destroyed to
confirm calibration accuracy
For more information on GE Disconnects and Circuit Breakerssee Publication Index Section 18
Fusible SwitchesNonfusible Switches
16-216-2
Type FD1 Fusible Disconnect Switches 16-3 16-4DILOS Nonfusible Disconnect Switches 16-5,16-6Molded Case Circuit Breakers 16-7 to 16-18Accessories and Modifications 16-19 to 16-32V-Line™ Miniature Circuit Breakers 16-33 to 16-36
1999 Issue 16-1