Page 1: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

GE Interlogix

Kalatel Division

Product Update

KTD-405 Programming& Standard Operations

Page 2: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 Keypad Programming

Page 3: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

KEYPAD ADDRESS: 99

KEYPAD 99

Boot-Up Screen

Page 4: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

CAMERA ---

MONITOR 1

Default display after applying power

Page 5: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Programming)

Navigating the menus

Key FunctionDisplays the next menu

Displays the previous menu

Scrolls up when indicated by in the menus

Scrolls down when indicated by in the menus

Scrolls right when indicated by in the menus

Scrolls left when indicated by in the menus

Scrolls up, down, left or right when indicated by , , , in the menus

Advances menus; exits menus if held for 3 secondsseq

Page 6: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Programming)

NOT IMPLEMENTED

Menus that were not available in the first releases of software are indicated by two beeps and the following display:

Page 7: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

Supervisor Programming

Page 8: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

To Access Programming: Press and hold the key

The unit will beep and show the following display

Remote device programming must be accessed separately.

Supervisor programming password is 1,4,7,6,

Also includes All user programming

ENTER PROGRAMMING

CODE:

seq

Page 9: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Resetting the Factory Defaults The first menu to display will be this one.

Press to advance to the next menu and to return to the previous menu at any time without changing any existing parameters

RESET TO DEFAULTS? NO

<+>=YES <->=NO NEXT

Page 10: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

1=RESET ALL BUT TITLES

2=RESET ALL

If you pressed “+” (yes): The next display will show:

Followed by:

Followed by:

The keypad will advance to the next menu automatically

ARE YOU SURE?

<+>=YES <->=NO NEXT

INITIALIZING DEFAULTS

PLEASE WAIT

Page 11: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Setting The Keypad Address The address is a “user defined” two-digit number

The address must be from 10 to 99

Each device on the RS-485 network must have a unique address

Address 99 is automatically assigned when the keypad is first connected and will remain unless changed by the user

Entering an address that is already used temporarily displays:

Select or to skip over this menu

KEYPAD ADDRESS: 99

(01-99) NEXT

ADDRESS NOT AVAILABLE

Page 12: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Backward Compatibility? If the KTD-405 is being used in a system with:

Existing ProBridges

Existing CBR-KB3 or CBR-KB3/J keypads

Select YES to allow the KTD-405 to communicate properly with these devices.

Select or to skip over this menu

KB3 PTZ PROTOCOL? NO

<+>=YES <->=NO NEXT

Page 13: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Allow Remote Programming by user? If the KTD-405 is being used in a system with:

Matrix Switchers or Multiplexers

Alarm Monitoring Equipment

Programmable Dome Cameras or Receivers

Select YES to allow the user to enter the 9,5,1, password and program these devices

Select or to skip over this menu

ENABLE REMOTE PRGMG? YES

<+>=YES <->=NO NEXT

seq

Page 14: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Programming Keypad Titles A keypad title can be up to 14 characters including:

A – Z and 0 - 9

Keypads with titles can use the “Seize Control” option

Supervisors can seize camera sites, multiplexers, VCRs, etc.

Supervisors can seize an entire zone in the ZONE mode

Use the joystick or these buttons to program the title

Select or to skip over this menu

KEYPAD TITLE: <>

NEXT

= , = , = , = ,

Page 15: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Changing the SEIZE CONTROL code Use the number keys to enter the new code

The keypad will advance to the next menu when the last digit is entered

Select or to skip over this menu

SEIZE CONTROL CODE: 8642

USE NUMBER KEYS NEXT

Page 16: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Changing the SEIZE CONTROL time Use the number keys to enter the new time

This is the number of minutes of inactivity before the keypad will exit the seize control mode

Select or to skip over this menu

SEIZE CONTROL TIME: 5

(1-10) MINUTES NEXT

Page 17: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Restricting access to presets Use the number keys to enter the new limit

This is the lowest preset number a user may change

Select or to skip over this menu

LOWEST USER PRGMD PRESET

(01-64) 58 NEXT

Page 18: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Programming the SOFT keys This feature is not yet implemented

Select -, or to skip over this menu

Pressing + displays the following message:

PROGRAM SOFT KEYS?

<+>=YES <->=NO NEXT

NOT IMPLEMENTED

Page 19: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Supervisor Programming)

Programming the ACCESS codes This feature is not yet implemented

Select -, or to skip over this menu

Pressing + displays the following message:

CHANGE ACCESS CODES?

<+>=YES <->=NO NEXT

NOT IMPLEMENTED

Page 20: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

User Programming

Page 21: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

To Access User Programming: Press and hold the key

The unit will beep and show the following display

User programming password is 5,7,9,

ENTER PROGRAMMING

CODE:

seq

Page 22: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Changing the Operating Mode Two choices are available:

Digiplex

Zone

Use the joystick or these buttons to select the mode

Select or to skip over this menu

OPERATING MODE: DIGIPLEX

<,>=SELECT NEXT

= , =

Page 23: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Setting the system size Enter the highest camera number in your system

Select or to skip over this menu

SYSTEM SIZE:

<CAMERAS> 511 NEXT

DigiPlex mode Menus

Page 24: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Setting the system size Enter the highest monitor number in your system

Select or to skip over this menu

SYSTEM SIZE:

<MONITORS> 64 NEXT

DigiPlex mode Menus

Page 25: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Setting the system size Enter the highest multiplexer number in your system

Select or to skip over this menu

SYSTEM SIZE:

<MPLXS> 32 NEXT

DigiPlex mode Menus

Page 26: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Setting the system size Enter the highest VCR number in your system

Select or to skip over this menu

SYSTEM SIZE:

<DSR/VCR> 32 NEXT

DigiPlex mode Menus

Page 27: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Setting the system size Enter the highest preset number in your system

Select or to skip over this menu

SYSTEM SIZE:

<PRESETS> 63 NEXT

DigiPlex mode Menus

Page 28: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Restricting system access This menu restricts access to specified cameras

Use the joystick or these buttons to select the camera

Select or to skip over this menu

CAMERA 000 ACCESS? YES

<+>=YES <->=NO NEXT

DigiPlex mode Menus

= , =

Page 29: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Restricting system access This menu restricts access to specified cameras

Use the joystick or these buttons to select the camera

Select or to skip over this menu

CAMERA 000 ACCESS? YES

<+>=YES <->=NO NEXT

DigiPlex mode Menus

= , =

Page 30: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Restricting system access This menu restricts access to specified monitors

Use the joystick or these buttons to select the monitor

Select or to skip over this menu

MONITOR 01 ACCESS? YES

<+>=YES <->=NO NEXT

DigiPlex mode Menus

= , =

Page 31: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Restricting system access This menu restricts access to specified recorder

Use the joystick or these buttons to select the recorder

Select or to skip over this menu

Pressing “+” displays this menu:

Enter a number from 0 to 511, or 0 for NONE or

Select or to skip over this menu

DSR/VCR 01 ACCESS? YES

<+>=YES <->=NO NEXT

DigiPlex mode Menus

VCR 01 MATRIX INPUT:

000 <0=NONE> NEXT

= , =

Page 32: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Restricting system access This menu restricts access to specified multiplexer

Use the joystick or these buttons to select the multiplexer

Select or to skip over this menu

MPLX 01 ACCESS? YES

<+>=YES <->=NO NEXT

DigiPlex mode Menus

= , =

Page 33: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

If you pressed “+” (yes): The next display will show:

Followed by:

Followed by:

The keypad will advance to the next multiplexer menu automatically

MPLX01 BRAND CBR DVMRe

<,>=SELECT NEXT

MPLX 01 MATRIX INPUT?

000 <0=NONE NEXT

SELECT MAX OUTPUTS: 02

<,>=SELECT NEXT

DigiPlex mode Menus

Page 34: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Programming the monitor offset Enter a number for the offset needed in your system

Select or to skip over this menu

MONITOR OFFSET

NUMBER: 0 NEXT

DigiPlex mode Menus

Page 35: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Queuing and announcing call-ins If you select “+” in this display:

You need to select either SINGLE or MULTIPLE tone here:

Also specify a monitor to display the queued calls:

Select or to skip over this menu

ANNUNCIATION? NO

<+>=YES <->=NO NEXT

CALL TONE TYPE? MULTIPLE

<,>=SELECT NEXT

SPOT MONITOR NUMBER: 0

<0=UNASSIGNED> NEXT

DigiPlex mode Menus

Page 36: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

End of menus notification Pressing from the previous menu will cause the

keypad to display this message:

Select or press and hold for 3 seconds to exit the menus

PRESS <SEQ> FOR 3

SECONDS TO EXIT

DigiPlex mode Menus

seq

Page 37: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Changing the Operating Mode Two choices are available:

DigiPlex

Zone

Use the joystick or these buttons to select the mode

Select or to skip over this menu

OPERATING MODE: ZONE

<,>=SELECT NEXT

= , =

Page 38: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Programming the Mode label This menu allows you to select one of several labels for

the LCD display during normal operations

Selections Include:

ZONE, MPLX, DVMR, TERR, BLDG

FLR, DEPT, STA, SITE, AREA

Select or to skip over this menu

LCD DISPLAY LABEL: ZONE

<,>=SELECT NEXT

Zone mode Menus

Page 39: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Programming the zone titles This menu allows you to select a title to display when

the specified zone is being accessed.

Select or to skip over this menu

Enter a two-digit code and the keypad will advance to the following menu automatically

Program the label characters the same way as keypad titles

Select or to skip over this menu

ENTER ZONE ADDRESS: 01

(01-16) NEXT

Zone mode Menus

ZONE 01 TITLE: <>

(01-16) NEXT

Page 40: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Programming the Zone type This menu allows you to identify the specific device

that makes up a zone:

Selections Include:

CALIBUR MMX, CBR DVMRe, CBR TRIPLEX,

CBR DUPLEX, CBR SIMPLEX, MATRIX SWCH,

Select or to skip over this menu

ZONE 01 HUB: CBR DVMRe

<,>=SELECT NEXT

Zone mode Menus

Page 41: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Setting the zone size (monitors) This menu restricts access only to available zone monitors

Use the number buttons to set the number of monitors

Select or to skip over this menu

Setting the zone size (cameras) This menu restricts access only to available zone cameras

Choices include 4, 9, 10, 16 and 32

Use the joystick or these buttons to select the mode

Select or to skip over this menu

ZONE 01 MON. OUTPUTS?

01 TO 02 NEXT

Zone mode Menus

ZONE 01 CAM. INPUTS? 16

<,>=SELECT NEXT

= , =

Page 42: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Programming zone access privileges Program the cameras that this keypad can access:

Program the monitors that this keypad can access:

Program user access to the zone’s recorder :

You should deny access unless you have a Triplex or MMX connected to a VCR using sub-macros.

ZONE 1 CAM 01 ACC? YES

<+>=YES <->=NO NEXT

ZONE 1 MON 01 ACC? YES

<+>=YES <->=NO NEXT

ZONE 1 RECORDER ACC? YES

<+>=YES <->=NO NEXT

Zone mode Menus

Page 43: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

If the Zone type is set to MATRIX SWCH: The zone size and access menus displays are slightly

different

ZONE 02 HUB: MATRIX SWCH

<,>=SELECT NEXT

Zone mode Menus

Page 44: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Programming zone size Program the first camera input number for this zone:

Program the number of monitors for this zone:

Program the number of camera inputs on this zone:

Choices include 4, 9, 10, 16 and 32

SELECT START INPUT: 032

<,>=SELECT NEXT

ZONE 02 MON. OUTPUTS:

01 TO 16 NEXT

ZONE 02 CAM. INPUTS: 64

<,>=SELECT NEXT

Zone mode Menus

Page 45: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Programming zone access privileges Program the cameras that this keypad can access:

Program the monitors that this keypad can access:

Program user access to the zone’s recorder :

You should deny access unless you have a Triplex or MMX connected to a VCR using sub-macros.

ZONE 02 CAM 01 ACC? YES

<+>=YES <->=NO NEXT

ZONE 02 MON 01 ACC? YES

<+>=YES <->=NO NEXT

ZONE 02 RECORD ACC? YES

<+>=YES <->=NO NEXT

Zone mode Menus

Page 46: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Queuing and announcing call-ins If you select “+” in this display:

You need to select either SINGLE or MULTIPLE tone here:

Also specify a monitor to display the queued calls:

Select or to skip over this menu

ANNUNCIATION? NO

<+>=YES <->=NO NEXT

CALL TONE TYPE? MULTIPLE

<,>=SELECT NEXT

SPOT MONITOR NUMBER: 0

<0=UNASSIGNED> NEXT

Zone mode Menus

Page 47: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

End of menus notification Pressing from the previous menu will cause the

keypad to display this message:

Select or press and hold for 3 seconds to exit the menus

PRESS <SEQ> FOR 3

SECONDS TO EXIT

Zone mode Menus

seq

Page 48: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

Remote Programming

Page 49: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Remote Programming)

To Access Remote Programming: Press and hold the key

The unit will beep and show the following display

User programming password is 9,5,1,

Correct password entry will cause the following display:

Each selection generates a different set of menus

ENTER PROGRAMMING

CODE:

1=SWITCHER/MPLX 2=ALARMS

3=CAMERA/RCVR EXIT

seq

Page 50: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Switcher/Multiplexer Programming Identify the device to be programmed

If you select “1” (440) enter the monitor number to use for programming the switcher

The keypad will display this message

1=440 2=CALIBUR

3=340/348 BACK

ENTER MONITOR NUMBER:

(1-64) BACK

SEE MONITOR FOR MENUS

HOLD SEQ <3 SEC> TO EXIT

Switcher/Mux Menus

Page 51: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Identify the device to be programmed

If you select “2” (CALIBUR) enter the RS-485 address of the unit to be programmed

The keypad will display this message

1=440 2=CALIBUR

3=340/348 BACK

ENTER CALIBUR ADDRESS:

(1-32) BACK

SEE MONITOR FOR MENUS

HOLD SEQ <3 SEC> TO EXIT

Switcher/Mux Menus

Page 52: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Identify the device to be programmed

If you select “3” (340/348) enter the monitor number to use for programming the switcher

The keypad will display this message

1=440 2=CALIBUR

3=340/348 BACK

ENTER MONITOR NUMBER:

(1-64) BACK

SEE MONITOR FOR MENUS

HOLD SEQ <3 SEC> TO EXIT

Switcher/Mux Menus

Page 53: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Alarm Programming The keypad will display this message

SEE MONITOR FOR MENUS

HOLD SEQ <3 SEC> TO EXIT

Alarm Menu

Page 54: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Camera/Receiver Programming (DigiPlex) Identify the device to be programmed

If you select “1” (CYBERDOME) enter the camera address to be programmed

The keypad will display this message

1=CYBERDOME 2=PTZ

3=AUXILIARY BACK

ENTER CYBERDOME SITE

NUMBER BACK

SEE MONITOR FOR MENUS

HOLD SEQ <3 SEC> TO EXIT

Camera/Receiver Menus

Page 55: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

Camera/Receiver Programming (Zone) Identify the device to be programmed, AND Make

sure you have selected the Zone before you enter programming

If you select “1” (CYBERDOME) enter the camera address to be programmed (address must be within the zone)

The keypad will display this message

1=CYBERDOME 2=PTZ

3=AUXILIARY BACK

ENTER ZONE 1 CAMERA

NUMBER__ BACK

SEE MONITOR FOR MENUS

HOLD SEQ <3 SEC> TO EXIT

Camera/Receiver Menus

Page 56: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (User Programming)

PTZ OR Auxiliary Programming If you select “2” or “3” from this menu

The keypad will display this message

1=CYBERDOME 2=PTZ

3=AUXILIARY BACK

NOT IMPLEMENTED

PTZ/Auxiliary Menus

Page 57: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

Standard Operation

Page 58: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)

CAMERA ---

MONITOR 1

Default display after applying power

DigiPlex mode

Zone Mode

ZONE – ZONE TITLE

CAMERA -- MONITOR -

Page 59: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)

Accessing System Information: Press and hold the key to display the system

information

The keypad will display

Use or to move between these additional system information displays

KEYPAD ADDRESS: 99

KEYPAD 99 NEXT

VERSION 0.1.07

Dec 20 2001 09:32:44

CAM MN MX RC PS QS MO AT

511 64 32 32 63 58 00 W

mon

Page 60: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)

Accessing Help displays: Press + to display the Help menu

In the help menus:

Pressing any key displays that key’s function

+ “key” displays that key’s shifted function

The help display will cease display after 10 seconds of inactivity

esc

esc

mon

Page 61: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)

Selecting a monitor: There are two ways:

Enter the monitor number with any preceding zeroes

Example: 1 (systems with less than 10 cameras)

Example: 01 (systems with more than 9 cameras)

Enter the monitor number, then press

Example: 1 +

CAMERA ---

MONITOR 1

Page 62: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)

Selecting a camera: There are two ways:

Enter the camera number with any preceding zeroes

Example: 3 (systems with less than 10 cameras)

Example: 03 (systems with less than 100 cameras)

Example: 003 (systems with more than 99 cameras)

Enter the camera number, then press

Example: 3 +

CAMERA ---

MONITOR 1

Page 63: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)

Controlling a camera: Select the camera to be controlled

Pan, Tilt and Zoom can be controlled by the joystick

Up/Down for Tilt control

Left/Right for Pan control

Twist the joystick for Zoom or use the key

Use the and keys for these functions

CAMERA 003

MONITOR 1

+zoom-

+iris- +focus-

Page 64: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)

Setting a preset: Position the camera

Press the Store key

Enter the preset number in one of three ways:

Enter the two-digit number (Ex. 05 or 16)

Use the AUX-1, AUX-2, AUX-3 or AUX-4 keys for 58-61

Use and for presets 62 and 63 (left and right Auto-Pan limits. Presets 62 and 63 can not be set by entering the two-digit numbers. On with these two keys and .

aux 1

store

Page 65: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Programming a Groups (salvos) and Tours: Requires a RS-485 connection and zone selected

Requires Switcher monitor groups to be previously programmed

Press Store + Sequence

This menu will display:

Enter a number from 1 to 64 calls that group of cameras on the monitors

If you press the Tour key the following menu is displayed:

Enter a number from 1 to 12 TO START that group sequence on the monitors

DigiPlex Mode

ENTER MONITOR GROUP

(1-64)-- OR <TOUR>

store seq

ENTER GROUP SEQUENCE

(1-12)--

tour

Page 66: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Controlling a recording device: Requires a KTD-93 interface (RS-422 to RS-232)

Key Function DSR/VCR Function DVMRe

Starts recording Starts recording

Stops record or playback Stops record or playback

Starts playback Starts playback

Pauses playback Pauses playback or live mode

Fast Forward Fast Forward

Fast Reverse (rewind) Fast Reverse (rewind)

Frame advance

Depends on device (DSR/VCR)

Play forward (from reverse play)

Frame advance (in pause mode)

Frame reverse

Depends on device (DSR/VCR)

Play reverse (from forward play)

Frame reverse (in pause mode

n/a 2X digital zoom toggle

n/aActivates play and displays search menu

Digiplex Mode

Page 67: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Controlling a recording device: Requires a KTD-93 interface (RS-422 to RS-232)

Key Function DSR/VCR Function DVMRe

Joystick

functions

↻ Twist right = variable rate forward

↺ Twist left = variable rate reverse

In Play or Pause modes:

↻ Twist right = variable rate forward

↺ Twist left = variable rate reverse

Skip forward 2MB (about 15 sec.)

Skip backward 2MB (about 15 sec.)

Fast Forward

Fast Reverse (rewind)

Return to center position resumes pause mode

In 2X Zoom mode:

Tilt up

Tile down

Pan right

Pan left

Digiplex Mode

Page 68: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Controlling a multiplexer: Requires RS-485 connection

Key Function Multiplexer Function VCR/DSR

Starts recording Starts recording

Stops record or playback Stops record or playback

Starts playback Starts playback

Pauses playback Pauses playback or live mode

Fast Forward Fast Forward

Fast Reverse (rewind) Fast Reverse (rewind)

Frame advanceFrame advance (in pause mode)

Frame reverseFrame reverse (in pause mode

2X digital zoom toggle n/a

Activates play and displays search menu

n/a

Zone Mode

Multiplexer must support sub-macro VCR interface

Page 69: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Controlling a multiplexer: Requires a RS-485 connection

Key Function Multiplexer Function DSR/VCR

Joystick

functions

n/a

In Play or Pause modes:

↻ Twist right = variable rate forward

↺ Twist left = variable rate reverse

In 2X Zoom mode:

Tilt up

Tile down

Pan right

Pan left

Zone Mode

Multiplexer must support sub-macro VCR interface

Page 70: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Programming a multiplexer AutoList sequence: Requires a RS-485 connection and zone selected

Press Store

Press Sequence

This menu will display:

Enter the first camera number in the sequence

Wait the desire amount of time you want this camera displayed

Enter the next camera number in the sequence

Wait the desire amount of time you want this camera displayed

Repeat procedure until all cameras have been entered in the sequence

Press to cancel or to exit and save the sequence and exit

Zone Mode

ENTER SEQUENCE CAMERA

CANCEL DONE

store

seq

Page 71: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Controlling a recording device: Requires a KTD-93 interface (RS-422 to RS-232)

Key Function DSR/VCR

Starts recording

Stops record or playback

Starts playback

Pauses playback

Fast Forward

Fast Reverse (rewind)

Frame advance

Depends on device (DSR/VCR)

Frame reverse

Depends on device (DSR/VCR)

Joystick↻ Twist right = variable rate forward

↺ Twist left = variable rate reverse

Zone Mode

Page 72: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Programming a Calibur™ multiplexer: Requires RS-485 connection

Enter programming via the Remote Programming code 9,5,1,

Select 1 for switcher/multiplexer

Select 2 for Calibur

Enter the Calibur RS-485 address

Press (ENTER)

Enter the Calibur password for the device

Zone Mode

seq

Page 73: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Programming a Calibur™ multiplexer: Navigate the Calibur multiplexer menus with these keys:

Key Function

Joystick moves left, right, up, down in menus

Makes selections

Backspaces out of selections or exits programming from the main menu

Move up in menus

Move down in menus

Move right in menus

Move left in menus

Same as

Same as

Zone Mode

esc

Page 74: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Keys with special functions: These keys have some special applications:

Key Function

Programmable two ways:

Use with number keys to display mult-image views (if supported)

Used to sequence through multi-display image views (if supported)

OPEN or Preset 58

CLOSE or Preset 59

STOP or Preset 60

TALK or Preset 61

Used for activating tours or Auto-Pan mode

Used to send the selected camera to a preset (if camera is capable)

Clears numerical menu entries (future function clears alarms)

Places selected CyberDome in auto-focus

Addresses remote recording device

view

aux 1

aux 2

aux 3

aux 4

tour

find

dsr/vcr

autofocus

esc

Page 75: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

KTD-405 keypad (Standard Operation)Keys with special functions: These keys have not been implemented yet:

Key Function

Alarm key

1st (First) key

alarm

1st

Page 76: GE Interlogix Kalatel Division Product Update KTD-405 Programming & Standard Operations

PYTANIA