GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – 1X Series (phase 1) Conventional Fire Panel

Upload: sasha-broadwater

Post on 14-Dec-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/1

GE internal information - Not for external distribution

1GE Security EMEA NPI template – v1

1X Series(phase 1)

Conventional Fire Panel

Page 2: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/2

GE internal information - Not for external distribution

2GE Security EMEA NPI template – v1

Signaling Devices

Up to 4 conventional zones with up to 32* devices per zone

FACP

Detection Devices

* Detector line dependent

2 x Inputs

240/110PSU

The 1X-F4 System

Up to 8 additional

supervised or un-

supervised auxiliary

relay outputs

Auxiliary Boards

Page 3: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/3

GE internal information - Not for external distribution

3GE Security EMEA NPI template – v1

The 1X-F4 System We decide to offer the customer the 1X-F4

2.8 kg

Page 4: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/4

GE internal information - Not for external distribution

4GE Security EMEA NPI template – v1

Preparation

• Cable Specifications

• System Specifications

• Bills of Quantities

• Standby Time

• Default System Configuration

• Planning the Installation

Page 5: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/5

GE internal information - Not for external distribution

5GE Security EMEA NPI template – v1

System Specifications System specifications (power supply for 2 and 4 zone panels)

•Mains Supply:110/240 VAC 50/60Hz (+10%/−15%) - < 2 A

•24 VDC Supply: (±2%) - < 2 A

•Batteries: (SLA) - < 7.2 Ah

•Battery charger:27.3 V @ 20ºC (−36mV/ºC) - < 0.5 A

•Auxiliary supply: - < 250 mA @ 21 - 28 VDC (24 V Nominal)

Page 6: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/7

GE internal information - Not for external distribution

7GE Security EMEA NPI template – v1

System Specifications System specifications (others - for 2 and 4 zone panels)

•Zone Supply: - < 65 mA @ 18-24 VDC (22 V nominal)

Zone equipment spec - < 2.6 mA

•Supervised Outputs: - < 250 mA @ 28 VDCSupervision Voltage - -15 VDC

•Unsupervised Outputs: - < 2 A @ 30 VDC

•Auxiliary Boards:Standard Relay Board - < 2 A @ 30 VDC

Supervised Relay Board - < 2.5 A @ 28 VDC

Page 7: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/9

GE internal information - Not for external distribution

9GE Security EMEA NPI template – v1

System Specifications Environmental specifications

•Temperature Specifications:Storage Temperature - -10 to +70°C

Operating temperature - -10 to +40°C

•Humidity: (non condensing) - 10 to 95%

•IP Rating: - IP30

Page 8: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/10

GE internal information - Not for external distribution

10GE Security EMEA NPI template – v1

Installing the Hardware in the Cabinet The hardware of the 1X-F4 (and 1X-F2) Back Box

Battery Plate

BS127N7.5 Ah Batteries

Mains Power Connector

1X-4F-MB

2010-1-RB / 2010-1-SB

2010-PS-20

1X-C2

Page 9: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/11

GE internal information - Not for external distribution

11GE Security EMEA NPI template – v1

Connecting the Field EquipmentSystem installation

INPUT1:unused

INPUT2:to the intrusion panel

Z1: to the showroom

Z2: to the office area

Z3: to the canteen

Z 4:unused

OUT1:showroom notification devices

OUT2:offices notification devices

OUT3:canteen notification devices

OUT4:unused

24V AUX:unused

FAULT: unused

FIRE: unused

Only required if non GE devices are used

Page 10: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/12

GE internal information - Not for external distribution

12GE Security EMEA NPI template – v1

Optional relay board required for door control• 2010-1-RB Un-supervised (4 relays COM-NO-NC)

Connected behind the mainPCB with a ribbon cablesupplied with therelay board.

Connectorsare still visibleand pluggable.

Connecting the Field EquipmentConnecting any auxiliary boards

SHOWROOM

OFFICES/TOILETS

CANTEEN

Page 11: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/13

GE internal information - Not for external distribution

13GE Security EMEA NPI template – v1

SHOWROOM

OFFICES/TOILETS

CANTEEN

The User InterfaceLocalisation

Easy language/country variant implementation allows for the panel to be available in local language using customised language inserts

Common control/indicator locationson all X series panels

Main indications

Main controls/indicators

Sounder controls/indicatorsFire routing controls/indicators

Maintenance controls/indicators

Page 12: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/14

GE internal information - Not for external distribution

14GE Security EMEA NPI template – v1

The User Interface Front panel (for everyone)

SHOWROOM

OFFICES/TOILETS

CANTEEN

Page 13: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/15

GE internal information - Not for external distribution

15GE Security EMEA NPI template – v1

The 7-Segment Display 7-Segment display (for the installer and maintenance engineer)

SHOWROOM

OFFICES/TOILETS

CANTEEN

Page 14: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/16

GE internal information - Not for external distribution

16GE Security EMEA NPI template – v1

The 7-Segment Display Features

ModeValue

• Provides the possibility to eliminate DIP switches and jumpers and makes the panel ready for PC programming

• Provides clear English menu extensions for easy configuration options

• Indicates default values ad user selections on 8th-segmentLEDs ON Default settingLEDs Blinking New selectionLEDs OFF No selection

• Indicates if in a main or sub menu with indication LEDs

Page 15: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/17

GE internal information - Not for external distribution

17GE Security EMEA NPI template – v1

Basic ProgrammingEntering basic programming mode

Default BASIC MENU password = 3333 and

The LED on RESET button indicates programming mode by blinking ON and OFF

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

Page 16: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/18

GE internal information - Not for external distribution

18GE Security EMEA NPI template – v1

Basic Programming The basic menu

ModeValue

43

1 2The basic menu allows the installer to set up most common parameters (if necessary) that are different to the factory default configuration.

Use the ^ (1) and v (3) keys to navigate through the menus.

Page 17: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/19

GE internal information - Not for external distribution

19GE Security EMEA NPI template – v1

Basic Programming The basic menu

ModeValue

43

1 2

Panel configuration using regional defaults sets all system parameters up for immediate use.

Press to access the sub-menu to change the basic operating mode.

ModeValue

Default value = 01

Use the ^ (2) and v (4) keys to navigate through the available options.

Page 18: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/20

GE internal information - Not for external distribution

20GE Security EMEA NPI template – v1

Basic Programming The basic menu – Modes of operation

43

1 2

ModeValue

Check/verify the default operating mode selected in the basic menu.

Press to access the sub-menu to view the basic operating mode.

ModeValue

Default value = En

Page 19: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/21

GE internal information - Not for external distribution

21GE Security EMEA NPI template – v1

Basic Programming The basic menu – Sounder Delay

ModeValue

43

1 2

Set the required sounder delay time.

Press to access the sub-menu to change the sounder delay time.

ModeValue

Default value = 00

Use the ^ (2) and v (4) keys to navigate through the available options.

Options: 01 to 10 minutesin 1 minute intervals

Page 20: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/22

GE internal information - Not for external distribution

22GE Security EMEA NPI template – v1

Basic Programming The basic menu – Fire Routing Delay

ModeValue

43

1 2

Here we set the required fire routing (fire brigade) delay time.

Press to access the sub-menu to change the fire routing delay time.

ModeValue

Default value = 00

Use the ^ (2) and v (4) keys to navigate through the available options.

Options: 01 to 10 minutesin 1 minute intervals

Page 21: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/24

GE internal information - Not for external distribution

24GE Security EMEA NPI template – v1

Basic Programming The basic menu – Number of modules

ModeValue

43

1 2

Set the number of auxiliary modules installed in the panel.

Press to access the sub-menu to change the number of auxiliary boards installed in the panel.

ModeValue

Default value = 00

Use the ^ (2) and v (4) keys to navigate through the available options.

Options: 00 to 04in 1 unit increments

Page 22: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/25

GE internal information - Not for external distribution

25GE Security EMEA NPI template – v1

Basic Programming The basic menu – Module A (only available when modules are configured)

ModeValue

43

1 2

Module A through D is assigned from left to right in the cabinet housing.

Press to access the sub-menu to change the module functionality.

ModeValue

Default = 01

Use the ^ (2) and v (4) keys to navigate through the available options.

Options: 01 to 92in unit increments

Page 23: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/26

GE internal information - Not for external distribution

26GE Security EMEA NPI template – v1

Basic Programming The basic menu – Restore configuration

ModeValue

43

1 2Returns the panel to the previous saved configuration.

Press to restore the panel to its previous configuration.

Page 24: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/27

GE internal information - Not for external distribution

27GE Security EMEA NPI template – v1

Basic Programming The basic menu – Factory configuration

ModeValue

43

1 2Returns the panel to the factory default configuration.

Press to return the panel to the factory default configuration.

Page 25: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/28

GE internal information - Not for external distribution

28GE Security EMEA NPI template – v1

Basic Programming The basic menu – Exit without saving

ModeValue

43

1 2Exits the basic menu without saving.

Press to exit the menu and abandon all changes.

The panel returns to normal operating mode.

Page 26: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/29

GE internal information - Not for external distribution

29GE Security EMEA NPI template – v1

Basic Programming The basic menu – Exit & Save

ModeValue

43

1 2Exits the basic menu and stores the latest configuration. The previous configuration is also saved as a backup.

Press to exit the menu and abandon all changes.

The panel returns to normal operating mode.

Page 27: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/30

GE internal information - Not for external distribution

30GE Security EMEA NPI template – v1

Basic ProgrammingExiting programming mode

After exiting the menu, the panel returns to normal operation.

Our application is set-up!

SHOWROOM

OFFICES/TOILETS

CANTEEN Remember that enabling the sounder

delay is a manual operation at EN54

level 2!

Page 28: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/31

GE internal information - Not for external distribution

31GE Security EMEA NPI template – v1

Advanced ProgrammingEntering advanced programming mode

Default ADVANCED MENU password = 4444 and

The LED on RESET button indicates programming mode by flashing ON and OFF

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

Page 29: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/32

GE internal information - Not for external distribution

32GE Security EMEA NPI template – v1

Advanced Programming The advanced menu -

ModeValue

43

1 2The advanced menu allows the installer to set up all configurations options.

Default Access Code = 4444 and

Use the ^ (1) and v (3) keys to navigate through the menu.

Page 30: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/33

GE internal information - Not for external distribution

33GE Security EMEA NPI template – v1

Advanced Programming The advanced menu – Auxiliary Reset

ModeValue

43

1 2

Allows the configuration mode of the auxiliary supply.

Press to access the sub-menu to change the module functionality.

ModeValue

Default = OF

Use the ^ (2) and v (4) keys to navigate through the available options.

Options: 0N or OF

Page 31: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/34

GE internal information - Not for external distribution

34GE Security EMEA NPI template – v1

FaultfindingExtensive diagnostic LEDs on the front panel

Faultfinding panel indications

• General Fault LED (Blinking)

This indication will always be accompanied by one of the other fault indicators (zone, device or function LEDs) to indicate the exact location of a problem.

Depending on the type of fault, this fault may reset automatically when the condition is removed or require user intervention.

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

Page 32: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/35

GE internal information - Not for external distribution

35GE Security EMEA NPI template – v1

Faultfinding panel indications

• Fire Routing Fault (blinking)

Supervision (open & short circuit detection) or overload fault on one of the fire routing outputs

This fault does not reset automatically

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 33: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/36

GE internal information - Not for external distribution

36GE Security EMEA NPI template – v1

Faultfinding panel indications

• Supply Fault (blinking)

Indicates a battery failure – no batteries, low batteries or high resistance failure

• Supply Fault (constant)

Indicates a mains or mains fuse failure

These faults reset automatically when the conditions are removed.

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 34: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/37

GE internal information - Not for external distribution

37GE Security EMEA NPI template – v1

Faultfinding panel indications

• Earth Fault (constant)

Indicates a connection (+ or -) to earth somewhere in the panel or field wiring.

This fault does not reset automatically.

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 35: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/38

GE internal information - Not for external distribution

38GE Security EMEA NPI template – v1

Faultfinding panel indications

• Out of Service (Constant)

The control panel is in-operative. It does not have sufficient power to operate on either mains or batteries.

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 36: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/39

GE internal information - Not for external distribution

39GE Security EMEA NPI template – v1

Faultfinding panel indications

• System fault

µProcessor failure SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 37: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/40

GE internal information - Not for external distribution

40GE Security EMEA NPI template – v1

Faultfinding panel indications

• Sounder Fault (blinking)

Supervision (open & short circuit detection) or overload fault on one of the sounder outputs.

This fault does not reset automatically

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 38: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/41

GE internal information - Not for external distribution

41GE Security EMEA NPI template – v1

Faultfinding panel indications

• Service Detector (constant)

Indicates that one or more detectors require servicing (CleanMe)*

Enter a valid password. Hold the silence buzzer key for 3 seconds. The zone in maintenance will be indicated on the zone fault LED for the affected zone.

* available on Dx700 series detectors only

This fault does not reset automatically.

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 39: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/42

GE internal information - Not for external distribution

42GE Security EMEA NPI template – v1

Faultfinding panel indications

• Expansion IO Fault

Communication and supervision (if applicable) fault on any of the auxiliary boards.

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 40: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/43

GE internal information - Not for external distribution

43GE Security EMEA NPI template – v1

Faultfinding panel indications

• Zone fault

Supervision (open & short circuit detection) or overload fault on the indicated zone.

This fault resets automatically when the condition is removed.

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

FaultfindingExtensive diagnostic LEDs on the front panel

Page 41: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/44

GE internal information - Not for external distribution

44GE Security EMEA NPI template – v1

TestingLamp Test

Can be performed at level EN54 level 1

Push and hold the test button for 3 seconds

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE

Page 42: GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel

GE job title/45

GE internal information - Not for external distribution

45GE Security EMEA NPI template – v1

TestingEntering test mode

Default EN54-2 level 2 password = 2222 and

LED on RESET button indicates LEVEL 2 mode by being constantly ON

Use the TEST button together with the test/disable buttons for:

Zones –to test up to 4 zones simultaneously

Fire Routing –to test the fire routing outputs

Sounder –to test the sounder outputs (if required)

-to test the auxiliary board outputs

SHOWROOM

OFFICES/TOILETS

CANTEEN

WAREHOUSE