ge molded case circuit breakers q line circuit … molded case circuit breakers q line circuit...
TRANSCRIPT
GE Molded Case Circuit Breakers
Q Line Circuit Breakers60°C/75°C Conductor HatingBox Type Terminals
Types TQL, THQL, TQB, THQB10-125 Amps10,000 Amps 1C, UL listed HACR
AmpereRating
TQL, THQL Plug-In • •
Catalog NumberList
Price,GO-138A
TQB, THQB Bolt-On
Catalog Number• List
Price,GO-135B
Single-Pole, 120/240 Volts ac
THQL1120
10®15®20®25303540455060
70
TQL1110THQL1115THQL1120THQL1125THQL1130THQL1135THQL1140THQL1145THQL1150THQL1160
THQL1170
$ 20.0020.2520.2520.2520.2521.2521.2521.2521.2521.25
42.50
TQB1110THQB1115 ,THQB1120THQB1125 . ;
THQB1130 ' 'THQB1135.THQB1140
.THQB1145THQB1150THQB1160
THQB1170
$ 19.7519.75
, 19.7519.7519.7519.7519.7519.7519.7519.75
38.00
Two-Pole, 120/240 Volts ac, Internal Common Trip
THQB2115
Two-Pole, 240 Volts ac, Internal Common Trip
Three-Pole, 240 Volts ac, Internal Common Trip
BreakerType
THQP
THQLTHHQLTXQL
TQDLTHQDL
AmpereRating
15-2530-50
15-3035-6070-100110-125
125-200
Wire Size AWG/kcmil*Cu
14-88-4
14-88-3
6-1/02-2/0
1/0-250
Al
12-8 .8-4
12-88-3
4-1/02-2/0
1/0-250
10®152025303540455060
70
809P
100
110125
TQL2110THQL2115THQL2120THQL2125THQL2130THQL2135THQL2140THQL2145THQL2150THQL2160
THQL2170
THQL2180THQL2190THQL21100
THQL21110THQL21125®
46.0046.0046.0046.0046.0047.7547.7547.7547.7547.75
95.00
131.00131.00131.00 .
284.00284.00
TQB2110THQB2115THQB2120THQB2125THQB2130THQB2135THQB2140 'THQB2145THQB2150THQB2160
THQB2170
THQB2180THQB2190THQB21100
_
43.5043.5043.5043.5043.5043.5043.5043.5043.5043.50
82.50
113.00113.00113.00
_
10® ,152025
. 303540455060
70
8090
100
TQL22010THQL22015THQL22020THQL22025THQL22030THQL22035THQL22040THQL22045THQL22050THQL22060
THQL22070
THQL22080THQL22090 ,THQL22100
133.00®133.00®133.00®133.00®133.00®133.00®133.00®133.00®133.00®133.00®
156.00®
221.00®221.00®221.00®
TQB22010THQB22015THQB22020THQB22025THQB22030
• THQB22035THQB22040THQB22045THQB22050THQB22060
THQB22070
THQB22080THQB22090THQB22100
113.00113.00113.00113.00113.00113.00113.00113.00113.00113.00
148.00
170.00170.00170.00
10®• 15
20' ,25 - •- •
30.35
* 40455060
70
8090
100 '
TQL32010THQL32015THQL32020THQL32025THQL32030THQL32035THQL32040THQL32045THQL32050THQL32060
THQL32070
THQL32080THQL32090THQL32100
165.00®165.00®165.00®165.00®165.00®165.00®165.00®165.00®165.00®165.00®
216.00®
245.00®245.00®245.00®
TQB32010®THQB32015THQB32020THQB32025THQB32030THQB32035THQB32040THQB32045THQB32050THQB32060
THQB.32070
THQB32080THQB32090THQB32100
139.00139.00139.00139.00139.00139.00139.00139.00139.00139.00
175.00
199.00199.00199.00
® 5000 AIC.® UL listed as SWD (Switching
Duty) rated. Suitable forswitching 120 Volt acfluorescent lighting loads.
Recommended for use asmain or submain breaker only.GO-138.Not UL listed.
* Solid or standard for 14-10 AWG.4-10 1999 Issue Prices and data subject to change without notice
GE Service Entrance Equipment
PowerMark Gold™ and Plus™ Load Centers
Catalog Number Guide for Load Centers(Catalog number for illustrative purposes only)
M 42 20
GE Identification
TypeM = Main breakerFM = Main fusibleL = Main lugLM = ConvertiblePL = Main lug (Thermoplastic)
Maximum Number 1" Spaces2, 4, 6...42
Insert for 3-Phase 4-WireLoad Centers
CU
Insert for SpecialsG or T = Factory installed ground barB = Bottom feed main breakerFL = Factory-installed feed-thru lugs
Insert for PowerMark GoldCU = Copper Bus
Enclosure TypeC = Combination surface/flushF = FlushS = SurfaceR = Outdoor
40 = 40 Amps70 = 70 Amps10 = 100 Amps12 = 125 Amps15 = 150 Amps
20 = 200 Amps22 = 225 Amps30 = 300 Amps40 = 400 Amps60 = 600 Amps
Catalog Number Guide for Q Line Plug-in Circuit Breakers(Catalog number for illustrative purposes only)
QL 15
GE Identification
Interrupting RatingH = 10kAICHH = 22kAICX = 65kAIC
. . / • • . ,
TypeQL = 1" plug-inQP = 1/2" plug-inQB = 1" bolt-on '"
Poles (1,2, 3)Voltac
Amper
Ground .Fault/Arc Fault Circuit InterrupterGF - 1-pole Ground Fault Circuit InterrupterGF1 = 2-pole Ground Fault Circuit InterrupterAF = 1-pole Arc Fault Circuit Interrupter
e Rating
| e . " • • • • i1 = 120/240V2 = 240V
*Omit character for THQP breakers, which are all 120/240V.
1-2 ,1999 Issue Data subject to change without notice
GE Molded Case Circuit Breakers
Molded Case Circuit BreakersSpectra RMS™, Spectra RMS™ with MicroVersaTrip Plus™ Trip Units, Spectra RMS™ with +MicroVersaTrip PM™ Trip Units, Thermal Magnetic and J/K with MicroVersaTrip® RMS-9 andPower+™ 4 Trip Units
How to OrderQLine• Thermal Magnetic Circuit Breakers• Molded-Case Switches
The catalog number as shown in the following pages includes thecomplete breaker or switch. TQD and TJD breakers are completewith Cu/AI line and load lugs.Spectra RMS™• Circuit Breakers
Determine the required breaker frame, 1C rating, and loadrequirements. Select frame, trip unit (rating plug), and lug, ifrequired, catalog numbers from the tables on pages 4-18 and4-19. Select field-mounted internal accessory catalog numbers,if required, on page 4-47. Select field-mounted externalaccessory catalog numbers, if required, on pages 4-48 through4-65. Order as separate items. For Spectra breakers withMicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Unitsrefer to page 4-26 through 4-35.
• Mag-Break Motor Circuit ProtectorsDetermine the required frame and ampere requirements.Select frame, trip unit (rating plug), and lug, if required, catalognumbers from the table on page 4-42. Select accessories asnoted above for circuit breakers. The same accessories areused with both circuit breakers and motor circuit protectors.Order as separate items.
• Molded-Case SwitchesDetermine the required frame and ampere requirements.Select frame and lug, if required, catalog numbers from the tableon page 4-20. Rating plugs are not used.-Select accessories asnoted above for circuit breakers. Internal accessories do notrequire dummy trips. The same accessories are used with bothcircuit breakers and molded-case switches. Order as separateitems.
Unless otherwise noted, all circuit breakers are UL listed in File E-11592.Molded-case switches are UL listed in File E-57546. Field-InstallableInternal Accessories are UL listed in File E-57253. Distribution CableAccessories for MicroVersaTrip Plus Trip Units and MicroVersaTrip PM TripUnits are UL listed in File E-57253.
E150 Line• Thermal Magnetic Circuit Breakers• Magnetic Circuit Breakers• Molded-Case Switches
The catalog numbers as shown in the following pages include thecomplete breaker or switch. All devices listed come with Cu/AI lineand load lugs. If line lugs are not required on a breaker, eliminate"WL" from catalog number; for molded-case switches see page4-3. Unless otherwise noted, all circuit breakers are UL listed inFile E-11592. Molded-case switches are UL listed in File E-57546.F 225 Line• Thermal Magnetic Circuit Breakers• Magnetic Circuit Breakers• Molded-Case Switches
These breakers are available with either noninterchangeable trips(designated Type TFJ) or interchangeable trips (designated TypesTFK/THFK). When ordering Type TFJ, catalog number includes
complete breaker, trip unit, Cu/AI line and load lugs factoryassembled. If line lugs are not required on a breaker, eliminate"WL" from catalog number, and subtract price of line lugs fromprice of complete breaker. If interchangeable trip (Types TFK/THFK) is required order one of two ways. "Complete circuitbreaker" price includes frame, trip, Cu/AI line and load lugs. Unitswill be shipped unassembled unless specified on order "must befactory assembled." If line lugs are not required on a breaker,eliminate "WL" from catalog number, and subtract price of linelugs from price of complete breaker. To order the frame, trip, andlugs separately, select the required components from table.Magnetic breakers must be ordered as components. A completebreaker consists of frame, trip unit, one line lug per pole and oneload lug per pole. Price of "Complete Circuit Breaker" vs. orderingframe, trip, and line and load lugs separately is the same.Molded-case switches can also be ordered as complete units(designated TFK—Y) or as separate components. They are ULlisted only as complete units. To indicate required lugs, seepage 4-3.Unless otherwise noted, all circuit breakers are UL listed in FileE-11592. Molded-case switches are UL listed in File E-57546.J 600 Line• Thermal Magnetic Circuit Breakers• Magnetic Circuit Breakers• Molded-Case SwitchesThese breakers are available with either noninterchangeable trip(designated Type TJJ) or interchangeable trip (designated TypeTJK and THJK). Type TJJ catalog numbers include frame, trip,Cu/AI line, and load lugs factory assembled. If line lugs are notrequired on the breaker, eliminate "WL" from catalog number, andsubtract price of line lugs from price of complete breaker.TJK breakers are available in two frames, 400 ampere frame(125 to 400 amperes) and 600 ampere frame (250 to 600amperes). Trip units are not interchangeable between frames."Complete Circuit Breaker" price includes frame, trip unit, Cu/AIline, and load lugs. Unit will be shipped unassembled unless orderspecifies "must be factory assembled." If line lugs are notrequired, eliminate "WL" from catalog number and subtract priceof line lugs from price of complete breaker.To order the frame, trip, and lugs separately, select the requiredcomponents from table. Magnetic breakers must be ordered ascomponents. A complete breaker consists of frame, trip, and oneline and one load lug per pole.Price of ordering "Complete Circuit Breaker" vs. frame, trip, andline and load lugs separately is the same.Molded-case switches can also be ordered as complete units(designated Type TJK—Y) or as separate components. They areUL listed only as complete units. To indicate required lugs, seepage 4-3.Unless otherwise noted, all circuit breakers are UL listed in File \E-11592. Molded-case switches are UL listed in File E-57546.
(continued on next page)
4-2 1999 Issue Data subject to change without notice
GE Molded Case Circuit Breakers
Molded Case Circuit BreakersQuick Reference GuideRatings do not apply to molded-case switches ,
TH
\
W(-
Q Line (UL File E-11592; Fixed Thermal Magnetic Trip Unit)
CircuitBreakerType
THQP®
TQL/TQB/TQC®
THQLffiTHQB®THQC®
THHQBffiTHHQC®
THHQL®
TXQL®TXQB®TXQC®
TQDL
THQDL
TQD®
THQD®
TJD
AmpereRating
15-50
10
15-70
15-125
15-100
15-70
15-100
15-70
15-125
15-100
15-30
125-200
125-200
100-225
100-225
100-225
100-225
250-400
No.. Poles
1
2
12
3
1
2
3
1
2
3
1
2
3
1
2
3
2
2
2
3
2
3
2
3
MaximumVoltage Rating
ac
120/240
120/240
240
120/240
240
120/240
240
120/240
240
120/240
240
120/240
120/240
240
240
240
240
240
240
dc •
-
-
-
-
-
—
—
-
-
'-
UL Listed Interrupting Ratings —rms Symmetrical Amps (In Thousands)
ac Voltage120
-
-
-
-
-
—
—
-
-
120/240
10
5®
—
10
—
22
—
22
—
65
—
10
22
10
—
22
—
22
—
240
—
5®
—
10
—
22
—
22
65
—
—
10
10
22
22
22
22
277
' -
-
-
-
-
__
—
-
480
-
-
-•
-
-
—
—
600
.-
-
-
-
-
—
—
dc Voltage125
-
-
-
-
-
—
—
250
-
-
-
-
-
—
—
10
Dimensions(In.)
H
3%2
3%2
3%2
3%2
3%2
3%2
6Yie
61/16
69/16
69/16
10V&
W
Vfe
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
2 ,
2
2%
4V&
23/4
41/8
81/4
D
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
3«/16
A
-
-
-
-
-'
—
—
2 /̂16
27/16
3<yi6
B
-
-
-
-
-
—
—
27/16
27/16
313/16
c
-
-
-
-
-
———
11/16
—11/16
1%
E
-
-
-
-
—
—
2%2
2%2
13/16
Std.Pack
100
50
5025
15
50
25
15
50
25
15
50
_ » j
— M50
25
15
12
12
1
1
1
1
1
1
CB3 (UL File E-51075; Fixed Thermal Magnetic Trip Unit)THQBTHQCTHQL...GF
THHQL...GF,THHQB...GF
15-30
15-30
1
2
' 1
120
120/240
120
-
—
10
-
22
_
10
— — — — — — —
3%2
3%2
1
2
1
2%
23/8 — — — —
10
10
10
© UL listed as HACR.© TQL1215&TQL1220,® Not UL listed.
1-pole, 240 Vac, not UL listed.
4-4 1999 Issue Data subject to change without notice