Mammography QUICK REFERENCE-7/1
SENOGRAPHE DS
YES
REAR
208V/30A/E4502EE
UPS E4502JS
9'-0"
8'-2 1/2"
12'-10" x 12'-2"
9'-8" X 9'-8"
delivery opening 28" X 79"
gantry floor anchored?gantry cable access?standard cable lengths
Gtry=16' OC-Gtry=16'voltage/amps/
MDC cat. No.
recommended ceiling heightminimum ceiling heightrecommended room sizeminimum room size
![Page 2: GEHC Site Planning Technical Guide Mammo QUICK GUIDE XLS 1](https://reader036.vdocument.in/reader036/viewer/2022073120/55cf9981550346d0339db2da/html5/thumbnails/2.jpg)
Mammography QUICK REFERENCE-7/1
YES
REAR
208V/30A/E4502EE
UPS E4502JK
9'-0"
8'-2 1/2"
14'-6" X 14'-0"
11'-6" x 11'-6"
delivery opening 30" X 77"
SENOGRAPHE 2000Dgantry floor
anchored?gantry cable access?standard cable lengths
Gtry=16' Aws-Gtry=16'voltage/amps/
MDC cat. No.
recommended ceiling heightminimum ceiling heightrecommended room sizeminimum room size
![Page 3: GEHC Site Planning Technical Guide Mammo QUICK GUIDE XLS 1](https://reader036.vdocument.in/reader036/viewer/2022073120/55cf9981550346d0339db2da/html5/thumbnails/3.jpg)
Mammography QUICK REFERENCE-7/1
SENOGRAPHE DMR
YES
REAR
voltage/amps 208V/30A
UPS E4502JK
9'-0"
8'-2 1/2"
11'-6" X 10'-0"
10'-0" x 10'-0"
delivery opening 30" X 77"
gantry floor anchored?gantry cable access?standard cable lengths
Gen=16' Gen-Gtry=16'
recommended ceiling heightminimum ceiling heightrecommended room sizeminimum room size
![Page 4: GEHC Site Planning Technical Guide Mammo QUICK GUIDE XLS 1](https://reader036.vdocument.in/reader036/viewer/2022073120/55cf9981550346d0339db2da/html5/thumbnails/4.jpg)
Mammography QUICK REFERENCE-7/1
SEISMIC Areas
REAR
voltage/amps 208V/20A
9'-0"
8'-2 1/2"
16'-4" X 11'-0"
10'-0" x 10'-0"
delivery opening 36" X 82"
INSTRUMENTARIUM (DIAMOND)gantry floor
anchored?gantry cable access?
recommended ceiling heightminimum ceiling heightrecommended room sizeminimum room size
![Page 5: GEHC Site Planning Technical Guide Mammo QUICK GUIDE XLS 1](https://reader036.vdocument.in/reader036/viewer/2022073120/55cf9981550346d0339db2da/html5/thumbnails/5.jpg)
Mammography QUICK REFERENCE-7/14
SEISMIC Areas
REAR
voltage/amps 208V/20A
9'-0"
8'-2 1/2"
16'-4" X 11'-0"
10'-0" x 10'-0"
delivery opening 36" X 82"
INSTRUMENTARIUM (PERFORMA)gantry floor
anchored?gantry cable access?
recommended ceiling heightminimum ceiling heightrecommended room sizeminimum room size