general information - marks supply€¦ · general information refer to for individual models....

61
General Information Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.i Refer to www.specselect.com for individual models. Catalogue Features Products have been presented by product family. Each catalogue sheet has been designed as a product submittal sheet. Included are photographs, features, specifications, line drawings, flowcharts and appropriate approvals. Also, pages showing selection charts, components, accessories, etc. have been included where appropriate. Vandal Resistant Colour Coded Index Stainless Steel Locking Pin O-Ring Seals Threaded Inlet Adaptor machined from free cutting brass rod Lot Identifying Date Stamp Floating Chrome Plated Brass Ball Seat for Check Piston Vandal Resistant Nozzle machined from free cutting brass rod Check Piston 1 Piece Cast Brass Body Forged Brass One Piece Vandal Resistant Handle/Stem W6200 Teck ® Rigid/Swivel gooseneck Bent from seamless brass pipe Machined from free cutting brass rod Specially designed raised lockwasher Machined from free cutting brass rod Stem structure is machined from free cutting brass rod and roll threaded Solid brass body Machined from free cutting brass rod W6700-9

Upload: others

Post on 30-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

General Information

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.i

Refer to www.specselect.com for individual models.

Catalogue FeaturesProducts have been presented by product family. Each catalogue sheet has been designed as a product submittal sheet. Includedare photographs, features, specifications, line drawings, flowcharts and appropriate approvals. Also, pages showing selectioncharts, components, accessories, etc. have been included where appropriate.

Vandal Resistant Colour Coded Index

Stainless SteelLocking Pin

O-Ring Seals

Threaded Inlet Adaptormachined from freecutting brass rod

Lot IdentifyingDate Stamp

Floating Chrome Plated Brass Ball

Seat for Check PistonVandal Resistant Nozzlemachined from freecutting brass rod

Check Piston

1 Piece Cast Brass Body

Forged Brass One PieceVandal Resistant Handle/Stem

W6200

Teck® Rigid/Swivel gooseneckBent from seamless brass pipe

Machined from free cutting brass rod

Specially designed raised lockwasher

Machined from free cutting brass rod

Stem structure is machined from freecutting brass rod and roll threaded

Solid brass body

Machined from free cutting brass rod

W6700-9

General Information

Refer to www.specselect.com for individual models.

Property Test Methods Chemicals Used Results

Finish UnaffectedHydrochloric acid: 36.97%Nitric acid: 70.69%Sulphuric acid: 96.4%

Fitting samples placed in a 6 cu. ft.plywood container together with abeaker of concentrated acid.Temperature maintained at 23°C(73°F) during test period of 150hours

Acid FumeResistance

Finish UnaffectedFitting samples placed in highhumidity cabinet maintained at 100%R.H. and 49°C (120°F) for a periodof 125 hrs.

High HumidityResistance

Finish UnaffectedFitting samples tested in accordancewith ASTM B117-61 for 1,000 hours

Salt Spray (Fog) Test

Finish UnaffectedArtificial sea water (composition per litre: 11 gm. MgCl2 6H2O,1.2 gm. CaCI2, 4 gm. Na2S04 and 25 gm. NaCI)

Fitting samples placed in salt fogcabinet for 125 hrs. at atemperature of 34-36°C (94-97°F)

Salt Fog CorrosionResistance

Finish UnaffectedAlkali (50% sodium hydroxide)Ethyl Alcohol,Toluol, Xylol,Benzol, Carbon Tetrachloride,Phenol, Mineral Oil

As above for acid resistanceReagent and SolventResistance

Finish UnaffectedNote: Discolouration and slightbubbling will occur withconcentrated sulphuric acid only

Hydrochloric acid: 36.9%

Nitric acid: 70.6%

Sulphuric acid: 96.4%

Acetic acid: 99.5%

Acid applied at rate of 60 drops perminute for 10 minutes. Fittings heldat an approximate 45° angle

Acid Resistance

Finishes Available A choice of three finishes – chrome plated, “C.R.” (Corrosion Resistant), and coloured epoxy are offered, which may be selected onthe basis of information provided in the chart below.

“C.R.” (Corrosion Resistant) Finish Physical Properties Chart

Finish Description Use Features

Good resistance to corrosionOn Fume Hood Outlets for colourcoding of services

High quality coloured bakedelectrostatically applied epoxy finish

Coloured Epoxy –Green, Blue,Yellow,Orange

Excellent resistance to corrosionColour harmonizes well with otherlaboratory equipment

Specially developed as a protectivecoating for unusually severe serviceconditions especially where finishmay come in contact with chemicalfumes, acids, alkalies and commonsolvents

A pleasing, grey/black, bakedfluorocarbon finish

“C.R.” (CorrosionResistant)

Good resistance to abrasion andcorrosionEasy to maintainRetains beauty for years

Recommended for all laboratoryapplications where finish will notcome in direct contact withchemical fumes, acids or alkalies

Electro-plated chromium provides ahard smooth surface with a deeplustre

Chromium Plate

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

General Information

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.ii

Refer to www.specselect.com for individual models.

Manufacturing Operation Alloy No. Copper AlloyNominal Composition

Copper Zinc Lead TinPipe 230 Red Brass, 85% 85% 15%

Pipe 272 Seamless Brass 63% 37%

Automatic Screw Machine 360 Free Cutting Brass 61.5% 35.5% 3%

Forging 377 Forging Brass 60% 38% 2%

Casting 844 Leaded Semi-Red Brass 81% 9% 7% 3%

COLORED EPOXY Finish Physical Properties ChartChemical resistance: Coating material shall meet the following performance requirements with respect to resistance to acids and solvents:

a) Suspend coated samples in a container at least 6 cubic feet in capacity, approximately 12" above open beakers, eachcontaining 100cc of 70% nitric acid, 94% sulphuric acid and 35% hydrochloric acid, respectively. After exposure to these fumes for 150 hours, the finish on the samples shall show no discolouration, disintegration or other effects.

b) Subject coated samples to the direct action of the following reagents and solvents at a temperature of 25°C dropping from aburette at the rate of 60 drops per minute for ten minutes:

Finish on the samples shall not rupture, though slight discolouration or possible softening is permissible.

Composition and ManufactureThe production and processing of component parts for laboratory fittings involves brass casting, forging, automatic screwmachining, roll-threading, bending, assembling, plating, coating, electrostatically applied epoxy painting and testing. Thisdiversification in manufacturing operations, with almost unlimited design scope, permits each fitting component to be fabricated by the method most appropriate to its application resulting in a very high, value-added quality case-work fitting. Fittings aremanufactured using alloy compositions noted in the table below:

AcetoneCarbon TetrachlorideEthyl Alcohol

Glacial Acetic Acid 99.5%Hydrochloric Acid 38%Mineral Oil

Sodium Hydroxide 50%Toluene

General Information

Refer to www.specselect.com for individual models.

Service Codes & ColoursFor products requiring Indexing, add the appropriate code to the part number. (i.e., W6200 for Nitrogen is W6200N)

De- De-SERVICE Hot Distilled ionized mineralized Carbon Cold & Reverse

Water Water Water Water Helium Propane Dioxide Hot Water Osmosis

Button Colour Red White White White Chrome Chrome Chrome Green & Red Chrome

English Code HW DW DI DM HE PRO CO2 CW/HW RO

French Code EC ED EF/EC

ColdSERVICE Gas Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water

English Part # T1278-8 T1278-13 T1278-6 T1278-10 T1278-7 T1278-9 T1278-11 T1278-12 T1278-1

French Part # T1278-38 T1278-43 T1278-42 T1278-31

De- De-SERVICE Hot Distilled ionized mineralized Carbon Reverse

Water Water Water Water Helium Propane Dioxide Osmosis

English Part # T1278-2 T1278-3 T1278-4 T1278-5 180140A 180142A 180145A W6973RO

French Part # T1278-32 T1278-33

• Special Indexing– Indexing other than standard is available using chrome buttons (with or without customer specified

lettering)– Check with customer service concerning use of particular valves with the service before ordering

(See Note Below)– For product requiring chrome index button(s) with no index, add “w/T3899” to catalogue number

i.e., Order as W6200 w/T3899– For product requiring chrome index button(s) with custom index, add “w/W6973” to catalogue number

i.e., Order as W6200 w/W6973Specify custom index required at time of ordering (Up to 3 letters)Note: Ball Valves in particular are tested differently depending on the service that they are supplied for.

i.e., Natural Gas/Propane – 1/2 psi– 125 psi

Non-Gas (i.e., Air, Nitrogen etc.) –125 psiVacuum – Tested for vacuum use only

T3899 Chrome Button (No Index)W6973 Chrome Button with Custom 3 Letter Index (Up to 3 Letters)

ColdSERVICE Gas Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water

Button Colour Dk. Blue Yellow Orange Grey White Pink Green Black Green

English Code Gas Vac Air N A H Oxy St CW

French Code Gaz Vide Vap EF

Ordering Index Buttons Only

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

General Information

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.iii

Refer to www.specselect.com for individual models.

NaturalGas/ Cold Hot Carbon Other

Propane Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water Water Helium Dioxide Services

Ball Valves Y Y Y Y Y Y N N Y3 N Y Y

Celcon Needle Valves N Y Y Y Y Y Y N Y Y Y YFloating S/S Needle Valves Y2 Y N Y Y Y Y Y N N Y Y–W6303 OnlyFloating S/S Needle Valves N N N N N N N Y N N N N–All Other Products

Compression Valves N N N N N N N N Y Y N N

VALVE TYPE Distilled Water

W6629 Recommended

SERVICE Recommended Operating Range

Gas 1.4 to 5.2 kPa (.2 to .75 psi)

Air 103 to 172 kPa (15 to 25 psi)

Vacuum 62 to 97 kPa (9 to 14 psi)

Oxygen 103 to 172 kPa (15 to 20 psi)

Steam 103 to 140 kPa (15 to 20 psi)

Water 345 to 552 kPa (50 to 80 psi)

Argon 70 to 103 kPa (10 to 15 psi)

Nitrogen 70 to 103 kPa (10 to 15 psi)

Hydrogen 7 to 34 kPa (1 to 5 psi)

Distilled Water 140 to 278 kPa (20 to 40 psi)

VALVE TYPE Maximum Testing Pressures

Ball 862 kPa (125 psi) at 21°C (70°F)

Needle (Both) 862 kPa (125 psi) at 21°C (70°F)

Compression 690 kPa (100 psi)

Distilled Water 414 kPa (60 psi)

Valve Selection Guide (based on services operating within recommended range shown below)

Y =Yes (Valve Type Useable)Y2 = Yes, US onlyY3 = Yes, up to 60 PSIN = No (Valve Type not Useable)• For Distilled Water, Deionized Water,

Demineralized Water, use Distilled Water Faucet only• Ball Valves provide Relatively Coarse Control

(1/4 turn to FULL open)

• All needle valves provide Fine Control (3 full turns to FULLopen)– Celcon Needle Valves have linear flow to rotational

relationship.All Stainless Steel Needle Valves have exponential flow torotational relationship.

– All Stainless Steel Needle valves recommended for up to20 psi Only. Celcon needle valves recommended forservices up to 100 PSI.

• Compression valves provide Coarse Control for water(1-3/4 turns to FULL open)

VALVE TYPE

Check

with

Technical

Service

SERVICE

Standard 3/8" Shanks and OptionsPART NUMBER 17117 T2714-1 T2714A-1 T2714A-2 T2714A-3 T2714A-4 T2714A-7 T2714A-8 060501A 060502AOVERALL LENGTH (4.06") (4.44") (4.44") (3.25") (2.38") (1.81") (2.75") (1.31") (2.0") (3.0")SERIES Suffix W — Suffix L Suffix M Suffix N Suffix P Suffix U Suffix V Suffix Q Suffix T

W6210-W6228 2.46 2.84* 1.65 1.15 1.40

W6270-W6279 3.56 3.94 2.75 1.88* 1.31 2.25 .81 1.50 2.50

W6350 2.46* 2.84 1.65 1.15 1.40

W6381 3.56 3.94 2.75 1.88 1.31 2.25* .81 1.50 2.50

Maximum Testing Pressures

Distilled Water Recommended Operating Range

EXPO

SED

LEN

GTH

*Standard Shank Supplied (no suffix required)

General Information

Refer to www.specselect.com for individual models.

*R1 is a Tubular Wall Gooseneck Spout.

All other gooseneck spouts listed are made from .09" heavy wall seamless brass pipe.

Note: Following is the procedure to use to PRICE and to ORDER a complete faucet with one of the above “OPTIONAL SPOUTS”:START with the BASE PRODUCT – Base Products for Group 1 Spouts – No Dash Style – Reg. G/N Spout w/Nozzle

-8 Style – Reg. G/N Spout w/Aerator-9 Style – Reg. G/N Spout w/Vac. Breaker

& NozzleBase Products for Group 2 Spouts – -10 Style – Ang. VB Spout w/Nozzle

-12 Style – Ang. VB Spout w/Filter Pump (No Diffusor)

ADD the OPTIONAL SPOUT selected from the above list. (Check standard spout offering first)

“A” “C” “L”Group Add-On Rigid/Swivel Spout

No. Suffix Description MM Inches MM Inches MM InchesR1 Regular Gooseneck Spout* 89 3.5 51 2 173 6.8

R2 Regular Gooseneck Spout 114 4.5 104 4.1 170 6.7

R3 Regular Gooseneck Spout 152 6 124 4.9 56 2.2

1 R4 Regular Gooseneck Spout 152 6 124 4.9 146 5.8

R5 Regular Gooseneck Spout 152 6 124 4.9 188 7.4

R6 Regular Gooseneck Spout 152 6 124 4.9 229 9

R7 Regular Gooseneck Spout 229 9 163 6.4 170 6.7

R8 Regular Gooseneck Spout 229 9 163 6.4 348 13.7

R22 Angle VB Gooseneck Spout 152 6 135 5.3 147 5.8

R23 Angle VB Gooseneck Spout 152 6 135 5.3 188 7.4

2 R24 Angle VB Gooseneck Spout 203 8 135 5.3 188 7.4

R25 Angle VB Gooseneck Spout 229 9 135 5.3 188 7.4

R26 Angle VB Gooseneck Spout 305 12 135 5.3 188 7.4

GROUP NO. 2Angle VBGooseneck

GROUP NO. 1RegularGooseneck

Optional Spouts (when ordered as part of a complete product) – ordering spouts only – see page 10.8.1

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Hose Cocks

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.1.1

Refer to www.specselect.com for individual models.

Laboratory Faucets, Ball Valve Hose Cock

OPTIONAL HANDLES – STD. SHOWN ABOVE

SERVICE CODES

EASY ORDER SYSTEM

OPTIONAL SHANKS – STD. SHOWN ABOVE

Catalog No. & Finish Code Non-Removable LeverNo Standard

CHROME CR Description Shank Handle

W6200 W6200-50 Ball valve hose cock with 3⁄8" M.I.P. inlet ✔

BV = Ball Valve C = Celcon Needle S = Stainless Steel Needle

Service Code Use

Air AIR BV/CArgon A BV/CCarbon Dioxide CO2 BV/CCold Water CW (EF) BV/CHelium HE BV/CHot Water HW (EC) CHydrogen H BV/CNatural Gas GAS (GAZ) BVNitrogen N BV/CPropane PRO BV

Service Code Use

Oxygen OXY CSteam ST (VAP) SVacuum VAC (VIDE) BV/C

S/S Needle: 20 P.S.I. Max., 255°F Max.

Celcon Needle: 100 P.S.I. Max.,180°F Max.

Ball Valve: 100 P.S.I. Max. (Gases)60 P.S.I. Max. (Cold Water)

180°F Max.

Description Suffix No.

1.31" Shank V1.81" Shank P2.00" Shank Q2.75" Shank U3.00" Shank T3.25" Shank M4.06" Shank W4.44" Shank L

Description Suffix No.

Green Plastic - Cold Water IOrange Plastic - Air GTwo Arm Metal BYellow Plastic - Vacuum H

CATALOG # & FINISH CODE SERVICE CODE OPTION CODES

No Handle substitution possible on non-removable Lever Handle.

(French Index shown in brackets)

Laboratory Faucets, Wall Flange with Hose Cocks (Ball Valve or Needle Valve)Catalog No. & Finish Code Standard Non-Removable Lever

Shank StandardCHROME CR Description 2.38" (N) Handle Black Plastic

W6270 W6270-50 Single ball valve hose cock with 17⁄8" wall flange, 1⁄4" I.P. tail ✔

W6273 W6273-50 Celcon needle hose cock with 17⁄8" wall flange, 1⁄4" I.P. tail ✔

W6274 W6274-50 Floating stainless steel needle hose cock with 17⁄8" wall flange, 1⁄4" I.P. tail (Steam Only) ✔

W6275 W6275-50 “Y” connector with 2 ball valve hose cocks, flange and 1⁄4" I.P. tail ✔

W6273 W6278 W6278-50 “Y” connector with 2 celcon needle hose cocks, flange and 1⁄4" I.P. tail ✔

W6279 W6279-50 “Y” connector with 2 floating stainless steel needle hose cocks, flange and 1⁄4" I.P. tail(Steam Only) ✔

A Use regular catalog pages to determine the product that you are looking for – 10.1.2 to 10.1.5• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

Hose Cocks

Refer to www.specselect.com for individual models.

A Use regular catalog pages to determine the product that you are looking for – 10.1.2 to 10.1.5• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

OPTIONAL HANDLES – STD. SHOWN ABOVE

SERVICE CODES

EASY ORDER SYSTEM

BV = Ball Valve C = Celcon Needle S = Stainless Steel Needle

Service Code Use

Air AIR BV/CArgon A BV/CCarbon Dioxide CO2 BV/CCold Water CW (EF) BV/CHelium HE BV/CHot Water HW (EC) CHydrogen H BV/CNatural Gas GAS (GAZ) BVNitrogen N BV/CPropane PRO BV

Service Code Use

Oxygen OXY CSteam ST (VAP) SVacuum VAC (VIDE) BV/C

S/S Needle: 20 P.S.I. Max., 255°F Max.

Celcon Needle: 100 P.S.I. Max.,180°F Max.

Ball Valve: 100 P.S.I. Max. (Gases)60 P.S.I. Max. (Cold Water)

180°F Max.

Description Suffix No.

Green Plastic - Cold Water IOrange Plastic - Air GTwo Arm Metal BYellow Plastic - Vacuum H

CATALOG # & FINISH CODE SERVICE CODE OPTION CODES

No Handle substitution possible on non-removable Lever Handle.

(French Index shown in brackets)

Laboratory Faucets, Deckmount Turrets with Hose Cocks (Ball Valve or Needle Valve)

OPTIONAL SHANKS – STD. SHOWN ABOVE

Description Suffix No.

2.75" Shank U3.00" Shank T3.25" Shank M4.06" Shank W

W6210

Catalog No. & Finish Code Standard Non-Removable LeverShank Standard

CHROME CR Description 4.44" (L) Handle Black Plastic

SINGLE VALVESW6210 W6210-50 Single ball valve hose cock, 1⁄4" I.P. tail ✔

W6213 W6213-50 Single celcon needle hose cock, 1⁄4" I.P. tail ✔

W6214 W6214-50 Single floating stainless steel needle hose cock, 1⁄4" I.P. tail (Steam Only) ✔

2 VALVES AT 90 DEGREESW6220 W6220-50 2 ball valve hose cocks @ 90 degrees, 1⁄4" I.P. tail ✔

W6223 W6223-50 2 celcon needle hose cocks @ 90 degrees, 1⁄4" I.P. tail ✔

2 VALVES AT 180 DEGREESW6225 W6225-50 2 ball valve hose cocks @ 180 degrees, 1⁄4" I.P. tail ✔

W6228 W6228-50 2 celcon needle hose cocks @ 180 degrees, 1⁄4" I.P. tail ✔

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Ball Valve Hose Cocks

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.1.2

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• Floating ball design• Vacuum valves supplied with Corrosion Resistant

ball and viton O-rings for improved durability• Vandal resistant handle – obvious on/off positions• Check valve to prevent contamination of service lines and valve

sealing surfaces• Vandal resistant 10 serration 3.2 mm (1/8") I.D. nozzle.

Removable with flat on one side• Rated to maximum 125 psi testing pressure• Meets ADA prescribed 5 lb. force pressure requirement• Life cycle tested to 100,000 cycles• Turret mounted units include vandal resistant locking pins to

prevent damage to mounting surface (can be removed in field if not required)

Valve OnlyW6200

Ball valve hose cock, floating ball-type design, 3/8" M.I.P. inlet,removable universal 10 serration vandal resistant nozzle,with 3.2 mm (1/8") outlet, forged brass vandal resistant handle, O-ringseals, check piston located in nozzle (with exception of vacuum service). Coloured index button to suit desired service

Wallmount ValvesW6270

Ball valve hose cock, 1 valve with flange, with shank,locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

W6275Wye connector with 2 ball valve hose cocks mounted at 90 degrees. Wallmounting with flange, shank, locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

Deckmount ValvesW6210

Deckmount turret with single ball valve hose cock, completewith vandal resistant locking pins, shank, locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece.

W6220Deckmount turret with 2 ball valve hose cocks mounted at90 degrees, complete with vandal resistant locking pins, shank,locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

W6225Deckmount turret with 2 ball valve hose cocks mounted at180 degrees, complete with vandal resistant locking pins, shank,locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

NaturalGas/ Cold Hot Carbon

Propane Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water Water Helium Dioxide Other Services

Ball Valves Y Y Y Y Y Y N N Y3 N Y Y

VALVE TYPE

Check withTechnicalService

SERVICEY = Yes N = No Y3 = Yes, up to 60 psi *Relatively Coarse Control (1/4 turn to full open)

W6210

W6200

W6270

Ball Valve Testing(1) Natural Gas/Propane – Tested at 1/2 psi & 125 psi(2) Vacuum – Tested for vacuum use only(3) Non-Gas (i.e., Air, Nitrogen) – Tested at 125 psi only

See Page 10.1.5 for additional ball valve features

W6275

See Page 10.1.5 for Selection Chart

Ball Valve Hose Cocks

DSP–W6200

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Approvals and Standards Met:

Note: To calculate flow rate in BTU/hr:(i) Using pressure at inlet of valve find flow rate in cubic feet per hour

from chart (left).(ii) Multiply BTU rating of gas service (BTU/ft3) by flow in CFH found

from (i) above, to give flow in BTU/hr.

CSA approved and tested to ANSI Z21.15 CAN/CGA – 3.16-M88 tested at both high pressure (125 psi) and low pressure (0.5 psi)ADA compliant and meets Handicapped Accessibility StandardASME A117.1 of less than 5 lb. force pressure requirements.

W6275Side View

W6210Side View

W6200Side View

W6200Top View

W6275Top View

W6270Side View

W6210Top View

Field Conversion1. Natural Gas/Propane valves should only be used for Natural

Gas/Propane.2. Vacuum valves should only be used for Vacuum.3. Non-Gas valves (i.e. Air, Nitrogen etc.) can be converted to any ”Y“

service (see 10.1.3) except Natural Gas/Propane or Vacuum.

FOR COMPLETE ORDERING INFORMATIONINCLUDING AVAILABLE OPTIONS,

SEE PAGE 10.1.1

Note: Measurements may vary ± 6mm (0.25'')

14mm(0.56")

1/4" NPT

1/4" NPT

38mm(1.5")

43mm(1.7")

90°

184mm(7.25")

14mm(0.56")

38mm(1.5")

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Celcon Needle Valve Hose Cocks

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.1.3

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:Celcon needle• Superior flow control providing the same rate of

change throughout handle turning range• Provides fine control (3 complete turns to FULL open)• Celcon needle is easily replaceable (wear is at

needle instead of seat which is typically harder to replace)

• Turret mounted units include vandal resistant locking pins to prevent damage to mounting surface (can be removed in field if not required)

Celcon Needle Valve Hose Cocks Testing: All services tested at125 psi Air under water.Needle hose cock for fine control of air, vacuum and various specialty gases. Renewable structure containing Celcon needle and chrome plated renewable seat, universal 10 serration vandalresistant nozzle.Note: Needle valves are supplied with black plastic handle as

standard.

Deckmount ValvesW6213

Deckmount turret with single needle hose cock, complete withvandal resistant locking pins, shank, locknut, lockwasher, couplingnut and 1/4" I.P. tailpiece

W6223Deckmount turret with 2 needle hose cocks, mounted at90 degrees, complete with vandal resistant locking pins, shank,locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

W6228Deckmount turret with 2 needle hose cocks, mounted at180 degrees, complete with vandal resistant locking pins,shank, locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

Wallmount ValvesW6273

Needle valve hose cock, 1 valve with flange, with shanklocknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

W6278Wye connector with 2 needle valve hose cocks, mountedat 90 degrees. Wallmounting with flange, shank, locknut,lockwasher, coupling nut and 1/4" I.P. tailpiece

NaturalGas/ Cold/Hot Carbon

Propane Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water Helium Dioxide Other Services

Celcon Needle N Y Y Y Y Y Y N Y Y Y

VALVE TYPE

Check withTechnicalService

SERVICE

Y = Yes N = No*Celcon needle valves recommended for services up to 100 psi

See Page 10.1.5 for Selection Chart

W6213

W6273

W6278

Celcon Needle Valve Hose Cocks

DSP–W6213

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Approvals andStandards Met:

CSA Certified toB125 withcompliance to ASME A112.18.1

®

W6213Side View

W6213Top View

W6278Top View

Note: Celcon needle valve hose cocks MAY NOT be used for natural or propane gases in Canada or U.S.

* Non-removable nozzle Note: Valves less nozzlesare not available.

W6273Side View

W6278Side View

FOR COMPLETEORDERING

INFORMATIONINCLUDING

AVAILABLE OPTIONS,SEE PAGE 10.1.1

L/s (IGPM)

Note: Measurements may vary ± 6mm (0.25'')

43mm(1.7")

185mm(7.25")90°

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Floating Stainless SteelNeedle Valve Hose Cocks

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:Floating Stainless Steel Needle• Provides fine control (3 complete turns to FULL open)• Exponential rate of change in flow throughout handle

turning range• Turret mounted units include vandal resistant locking

pins to prevent damage to mounting surface (can beremoved in field if not required)

• Needle valves are supplied with black plastic handleas standard

Needle hose cock for steam. Renewable structure containing floating stainless steel needle and renewable seat, universal 10 serration vandal resistant nozzle.

Deckmount ValvesW6214

Deckmount turret with single needle hose cock, complete withvandal resistant locking pins, shank, locknut, lockwasher, couplingnut and 1/4" I.P. tailpiece

Wallmount ValvesW6274

Needle valve hose cock, 1 valve with flange, with shank,locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

W6279Wye connector with 2 needle valve hose cocks mountedat 90 degrees. Wallmounting with flange, shank, locknut, lockwasher, coupling nut and 1/4" I.P. tailpiece

See Page 10.1.5 for Selection Chart

NaturalGas/ Cold/Hot Carbon

Propane Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water Helium Dioxide Other Services

Stainless Steel Needle N N N N N N N Y N N N

VALVE TYPE

Check withTechnicalService

SERVICE

Y = Yes N = No * Floating stainless steel needle valves recommended for up to 20 psi only.

W6214

W6274

W6279

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.1.4

Floating Stainless SteelNeedle Valve Hose Cocks

DSP–W6214

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

W6214Side View

W6214Top View

W6279Top View

* Non-removable nozzle Note: Valves less nozzlesare not available.

W6274Side View

W6279Side View

FOR COMPLETE ORDERING INFORMATION INCLUDING AVAILABLE OPTIONS, SEE PAGE 10.1.1

43mm(1.7")

185mm(7.25")90°

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Selection Chart

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.1.5

Refer to www.specselect.com for individual models.

W6270 W6273 (C)W6274 (SS)

W6275 W6278 (C)W6279 (SS)

W6210 W6213 (C)W6214 (SS)

W6220 W6223 (C)

W6225 W6228 (C)

Ball Valve Needle Valve

With 1/4" I.P. Tailpiece and Coupling Nut

With 1/4" I.P. Tailpiece and Coupling Nut

C = CelconSS = Stainless Steel

Double Post (180°) & Shank Pkg.

Double Post (90°) & Shank Pkg.

Single Post & Shank Pkg.

90º Wye & Shank Pkg.

3/8" Coupling Nut, Flange & Shank Pkg.

SEE PAGE 10.1.1 FOR COMPLETE LISTING OF FINISHES AND ORDERING OPTIONS AVAILABLE.

3/8" MNPT

3/8" NPT

Ball Valve Advantages(Over tapered plug-type valves)

Refer to www.specselect.com for individual models.

Vandal Resistance• Check-Piston located in outlet nozzle…

– Prevents water from entering gas line and flooding it.– Prevents insertion of thin objects (i.e., pencils) into open

valve which if broken off could cause damage to sealingsurfaces, resulting in a gas leak.Note: Check piston not included with vacuum service.

• Handle cannot be removed…- Handles in most tapered plug-type valves can easily beremoved resulting in a dangerous gas leak.

Safety• CSA approved and tested to ANSI Z21.15,

CAN/CGA-3.16-M88.• Tested at high (125 psi) and low (0.5 psi)

pressures.

Functional Performance• Cannot be damaged by high pressure testing which tends to

“blow-out” grease seals in tapered plug-type valves.• Floating ball-type design allows for minimum friction and

permits easy finger-type control compared to the inherentstiffness of a tapered plug-type valve.

• Maintenance free…There is no need to regrease sealingsurfaces or take valve apart.

• Longer Life…Because of it’s design (mating metal-to-metalsurface with a grease seal) a plug-type valve has it’s sealwear out much faster than a ball valve which has no metal-to-metal sealing surfaces (O-Ring seals are used).

• Meets ADA prescribed 5 lb. force pressure requirement.

Note: Delta Faucet offers a 10 year warranty on all ball valves– Best in the industry – every ball valve carries it’s date of manufacture on the underside of the body.

Vandal ResistantColour Coded Index

Stainless SteelLocking Pin

O-Ring Seals

Threaded Inlet Adaptor

Lot IdentifyingDate Stamp

Floating Chrome Plated Ball

Seat for Check PistonVandal Resistant Nozzle

Check Piston

1 Piece Cast Brass Body

Vandal Resistant One PieceHandle/Stem

10 YEAR

WARRANTY

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Remote Controls

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.2.1

Refer to www.specselect.com for individual models.

A Use regular catalog pages to determine the product that you are looking for – 10.2.3 to 10.2.6• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

SERVICE CODES

Service Code Use

Air AIR CArgon A C/SCarbon Dioxide CO2 C/SCold Water CW (EF) COMP/CHelium HE C/SHot Water HW (EC) COMP/CHydrogen H C/SNatural Gas GAS S (U.S. only) Nitrogen N C/S

Service Code UseOxygen OXY C/SPropane PRO S (U.S. only)Steam ST (VAP) SVacuum VAC (VIDE) C/S

S/S Needle: 20 P.S.I. Max., 255°F Max.

Celcon Needle: 100 P.S.I. Max., 180°F Max.

Compression: 100 P.S.I. Max., 180°F Max.

C = Celcon Needle S = Stainless Steel Needle COMP = Compression Valve

OPTIONAL HANDLES – STD. SHOWN ABOVE

Description Suffix No.

Black Plastic ATwo Arm Metal B

Catalog No. & Finish Code

CHROME CR Description

W6303 W6303-50 Front-service, floating stainless steel needle valve with plastic handleNote: Floating stainless steel needle valve not recommended above 20 PSI

W6308 W6308-50 Front-service, compression valveW6309 W6309-50 Front-service, celcon needle valve with plastic handle

Front Service Remote Control Valves (Compression or Needle)

CW = GreenOthers = Black

Standard Handles - W6303/W6309 Standard Handles - W6308CW = Green

HW = Two Arm MetalGas = BlueAir = Orange Vac = Yellow

EASY ORDER SYSTEM

CATALOG # & FINISH CODE SERVICE CODE OPTION CODE

Catalog No. & Finish CodeSuffix

CHROME CR BLUE GREEN ORANGE YELLOW Description No.

W6381-3 W6381-53 W6381-3BL W6381-3GR W6381-3OR W6381-3YL Wallmount flange with angle nozzle U

Wallmount Nozzles for Remote Control

EASY ORDER SYSTEM

CATALOG # & FINISH CODE OPTION CODEOPTIONAL SHANKS – STD. SHOWN ABOVE

Description Suffix No.

1.31" Shank V1.81" Shank P2.00" Shank Q2.38" Shank N2.75" Shank U3.00" Shank T3.25" Shank M4.06" Shank W4.44" Shank L

Remote Controls

Refer to www.specselect.com for individual models.

Catalog No. & Finish Code Standard Ext. RodStd.

CHROME CR Description Water Other Serv. Handle

W6300 W6300-50 R.C. ball valve with oblong flange 28" 10" FW6300-6 W6300-56 R.C. ball valve with 45° flange 28" 10" F W6300-7 W6300-57 R.C. ball valve with round flange – metal fume hood 28" 10" F

OPTIONAL EXTENDED ROD LENGTHS– STD. SHOWN ABOVE

SERVICE CODES

Service Code Use

Air AIR BV/CArgon A BV/CCarbon Dioxide CO2 BV/CCold Water CW (EF) BV/C/COMPHelium HE BV/CHot Water HW (EC) C/COMPHydrogen H BV/CNatural Gas GAS (GAZ) BVNitrogen N BV/CPropane PRO BV

Service Code Use

Oxygen OXY CVacuum VAC (VIDE) BV/C

Celcon Needle: 100 P.S.I. Max., 180°F Max.

Ball Valve: 100 P.S.I. Max. (Gases)60 P.S.I. Max. (Cold Water)

180°F Max.

Compression Valve: 100 P.S.I. Max.180°F Max.

BV = Ball Valve C = Celcon Needle COMP = Compression Valve

Description Suffix No.

10" S28" Z

OPTIONAL HANDLES – STD. SHOWN ABOVE

Description Suffix No.

Black Plastic AGreen Plastic - Cold Water IOrange Plastic - Air GTwo Arm Metal BYellow Plastic - Vacuum HLever Metal FBlue Plastic - Gas (U.S. only) Y

Remote Control Ball Valves

W6300

Catalog No. & Finish Code Standard Ext. RodStd.

CHROME CR Description Water Other Serv. Handle

W6304 W6304-50 Angle compression valve with oblong flange 28" — BW6304-6 W6304-56 Angle compression valve with 45° flange 28" — BW6304-7 W6304-57 Angle compression valve with round flange 28" — BW6305 W6305-50 Angle celcon needle valve with oblong flange 28" 10" AW6305-6 W6305-56 Angle celcon needle valve with 45° flange 28" 10" AW6305-7 W6305-57 Angle celcon needle valve with round flange 28" 10" A

Remote Control Valves (Compression or Needle)

W6305

EASY ORDER SYSTEM

CATALOG # & FINISH CODE SERVICE CODE OPTION CODES

A Use regular catalog pages to determine the product that you are looking for – 10.2.3 to 10.2.6• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Remote Controls

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.2.2

Refer to www.specselect.com for individual models.

Faucet Outlets for Remote Control

OPTIONAL SPOUTS – OPTIONAL SPOUT MUST BE SAME TYPE AS STD. SPOUT (I.E., REGULAR OR ANGLE VB)

Suffix “A” “C” “L”Number mm inches mm inches mm inches

REGULAR R1 89 3.5 51 2 173 6.8R2 114 4.5 104 4.1 170 6.7R3 152 6.0 124 4.9 56 2.2R4 152 6.0 124 4.9 146 5.8R5 152 6.0 124 4.9 188 7.4R6 152 6.0 124 4.9 229 9R7 229 9.0 163 6.4 170 6.7R8 229 9.0 163 6.4 348 13.7

ANGLE R22 152 6.0 135 5.3 147 5.8VB R23 152 6.0 135 5.3 188 7.4

R24 203 8.0 135 5.3 188 7.4R25 229 9.0 135 5.3 188 7.4R26 305 12.0 135 5.3 188 7.4

A

A

L

L

C

C

X

O

Std. Spout ( )X = Regular

O = Angle VB

EASY ORDER SYSTEM

CATALOG # & FINISH CODE OPTION CODES

OPTIONAL SHANKS– STD. SHOWN ABOVE

Description Suffix No.

1.31" Shank V1.81" Shank P2.00" Shank Q2.38" Shank N2.75" Shank U3.00" Shank T3.25" Shank M4.06" Shank W4.44" Shank L

A Use regular catalog pages to determine the product that you are looking for – 10.2.3 to 10.2.6• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

Catalog No. & Finish CodeStd.

CHROME CR GREEN Description ShankWALLMOUNT SPOUTS WITH 1/2” TUBE CONNECTION

W6350 W6350-50 W6350GR Wallmount turret with rigid/swivel gooseneck and nozzle W X (R4)

W6350-9 W6350-59 W6350-9GR As W6350 but with in-line vacuum breaker and nozzle W X (R4)

W6350-10 W6350-60 W6350-10GR As W6350 but with angle vacuum breaker and nozzle W O (R22)

W6350-12 W6350-62 W6350-12GR As W6350-10 but with 77423 Aspirator W O (R22)WALLMOUNT SPOUTS LESS 1/2” TUBE CONNECTION

W6350-39 W6350-89 W6350-39GR As W6350 but with vacuum breaker and nozzle, less elbow connection W X (R4)

W6350-40 W6350-90 W6350-40GR As W6350, but w/W6850-1 rigid/swivel gooseneck w/nozzle,less elbow connection W O (R22)

W6350-42 W6350-92 W6350-42GR As W6350-40, but with 77423 Aspirator W O (R22)

Remote Control Fume HoodValves (Front Access)

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.2.3

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Y = Yes N = No Y2 = Yes, US only

* Floating stainless steel needle valves recommendedfor up to 20 psi only.

** Celcon needle valves recommended for services up to100 psi.

Features:• Front access to structure and renewable seat• Durite washer for positive gripping during installation• Cast brass locknut• 1 piece cast brass body• Plastic molded handle matched to service colour standards• Easily replaceable stem structure• O-rings made from nitrile (Compression) or EDPM (needle)

Floating Stainless Steel Needle Structure• Fine Control: 3 complete turns to FULL open• 58 cu.ft./hr. flow at 1/2 psi• Life tested to 60,000 cycles under both high and low pressure• Self-centering, stainless steel needle• Renewable brass seat

Celcon Needle Structure• Fine Control: 3 complete turns to FULL open

W6303 (Gases) W6309 (Gases)Front access needle valve with self-centering, stainless steel needle(W6303) or with Celcon Needle (W6309), and replaceable stemstructure. 3/8" F.I.P. inlet and outlet. All cast brass body andlocknut, durite washer, renewable brass seat and Plastic moldedhandle. Colour of handle to match service standard for natural gas(blue), air (orange) and vacuum (yellow). All other services to havestandard black-plastic handle. All exposed parts (with exception ofhandle) are chrome platedNote: W6303 usable for natural gas/propane in U.S.

only. Not approved in Canada.

Compression Structure• Coarse Control: 1-3/4 turns to FULL open• 6.8 IGPM (8.2 USGPM) water flow at 60 psi• Life tested to 500,000 cycles• Teck® Lab Structure• Renewable C.P. brass seat

W6308 (Water)Front access compression valve with Teck® Lab structure andreplaceable stem. 3/8" F.I.P. inlet and outlet. All cast brass bodyand locknut, durite washer, renewable chrome-plated brass seatand Plastic molded handle. Colour of handle to match servicestandard for cold water (green). All other services to havestandard chrome-plated 2 arm Teck® lab handle. All exposed parts are chrome-plated

NaturalGas/ Cold/Hot Carbon

Propane Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water Helium Dioxide Other Services

Floating S/S (W6303)* Y2 Y N Y Y Y Y Y N Y YCelcon (W6309)** N Y Y Y Y Y Y N Y Y YCompression (6308) N N N N N N N N Y N N

VALVE TYPE

Check withTechnicalService

SERVICE

W6303 / W6308 / W6309

Floating Stainless SteelNeedle Structure

CompressionStructure

Celcon NeedleStructure

Remote Control Fume HoodValves (Front Access)

DSP–W6303

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Approvals and Standards Met:W6308 compliant to ASME A112.18.1W6303 is CSA approved and tested to ANSI Z21.15

Note: W6303 can NOT be used for natural gas or propane in Canada.

W6303/W6309Suggested Specifications:Valve shall be front access-type with renewable brass seat andstem structure. Needle shall be constructed of stainless steel and be self-centering (W6303) or of Celcon (W6309), body andlocknut shall be cast brass. Non-slip durite washer to be provided.Inlet and outlet shall be 3/8" F.I.P. Handle shall be made ofmolded Plastic. All exposed parts to be chrome-plated (withexception of handle).

W6308Suggested Specifications:Valve shall be front access-type with renewable, chrome-platedbrass seat, and stem structure. Body and locknut shall be castbrass. Non-slip durite washer to be provided. Inlet and outlet shall be 3/8" F.I.P. Handle shall be made of molded Plastic (or chrome-plated 2 arm Teck® lab handle). All exposed parts to be chrome plated (with exception of Plastic handle).

W6303Floating Stainless SteelNeedleW6309Celcon Needle

W6308Compression

FOR COMPLETE ORDERING INFORMATIONINCLUDING AVAILABLE OPTIONS,

SEE PAGE 10.2.1

Note: Measurements may vary ± 6mm (0.25'')

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Rod-Type Fume Hood Valves

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.2.4

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• All metal construction• W6300 – less than 5 lb. turning force required

– visual on/off indication• W6305 – offers superior handle turn to flow ratio

Ball Valves (Various Services – Coarse Control)• 28" rod supplied for water service• 10" rod supplied for all other services• Metal lever handle standard (ADA compliant)

W6300Rod controlled, floating ball-type valve complete with forged brassADA compliant handle, O-ring seals, 3/8" F.I.P. inlet and outlet,3/8" F.I.P. elbow, flange, 10" or 28" brass rod, coloured indexbutton to suit desired service

W6300-6As W6300, but with angled flange for 45 degree mounting

W6300-7As W6300, but with round flange for 90 degree mounting onmetal Fume Hoods

Compression Valves (Water Only – Coarse Control)• 28" rod supplied as standard• 2 arm metal handle standard

W6304Rod controlled angled compression valve, complete with 3/8"F.I.P. inlet and outlet, Teck® Lab compression structure, C.P. renewable seat, flange, 28" brass rod. Coloured index button to suit desired service

W6304-6As W6304, but with angled flange for 45 degree mounting

W6304-7As W6304, but with round flange for 90 degree mounting onmetal Fume Hoods

Celcon Needle Valves (Various Services – Fine Control)• 28" rod supplied for water services• 10" rod supplied for all other services• black plastic handle standard• recommended for services up to 100 psi

W6305Rod controlled angled Celcon needle valve complete with taperedcelcon disc coupled with a fine thread stem to provide fine control,3/8" F.I.P. inlet and outlet, Teck® Lab Celcon needle structure, C.P.renewable seat, flange, 10" or 28" brass rod. Coloured index button to suit desired service

W6305-6As W6305, but with angled flange for 45 degree mounting

W6305-7As W6305, but with round flange for 90 degree mounting onmetal Fume Hoods

NaturalGas/ Cold Hot Carbon

Propane Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water Water Helium Dioxide Other Services

Ball Valve Y Y Y Y Y Y N N Y3 N Y YCompression N N N N N N N N Y Y N NCelcon Needle** N Y Y Y Y Y Y N Y Y Y Y

VALVE TYPE

Check withTechnicalService

SERVICE

Y = Yes N = No Y3 = Yes, up to 60 psi**Celcon needle valves recommended for services up to

100 psi

W6300

W6305

Rod-Type Fume Hood Valves

DSP–W6300

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

W6300 Ball Valve

W6305 Celcon Needle

W6304 Compression

Flange Offerings“No Dash” Products“-6” Products

“-7” Productsfor Metal Fume Hoods

29mm[1.13"]

29mm[1.13"]

FLOW RATE - ML/S [CFM]FOR:1 - Celcon needle valves and ball valve hose cocks with

3.2mm (1/8") nozzles2 - Celcon needle valves with 6.4 mm (1/4")

AIR FLOW CELCON NEEDLE & BALL VALVES

WATER FLOW COMP.CELCON NEEDLE & BALL VALVES

NATURAL GAS FLOWBALL VALVE ONLY

FLOW RATE - L/s (IGPM)FOR:1 - Celcon needle valves and ball valve hose cocks with

3.2 mm (1/8") nozzles2 - Celcon needle valves with 6.4 mm (1/4")3 - Compression valves with 6.4 mm (1/4") nozzles

FOR COMPLETE ORDERINGINFORMATION INCLUDING

AVAILABLE OPTIONS,SEE PAGE 10.2.1

Note: Measurements may vary ± 6mm (0.25'')

Approvals and Standards Met:W6300 CSA approved and tested to ANSI Z21.15, CAN/CGA –3.16-M88. Currently only remote control valve listed for laboratoryuse by CSAW6300 Ball Valve Series with Lever Handle ADA compliant and meetsHandicapped Accessibility Standard ASME A117.1 of less than 5 lb.operation force W6304/W6305 CSA certified to B125 with compliance to ASMEA112.18.1

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Fume Hood Outlets

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.2.5

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• Teck® rigid/swivel gooseneck

– Unique vandal resistant design permits field installation as arigid or swivel gooseneck

– Heavy-duty gooseneck made from seamless brass pipe• Forged brass turret with vandal resistant locking pins to prevent

damage to fume-hood surface (can be removed in field if notrequired)

• Raised lockwasher to provide positive gripping during installation

• Two shank connection variations– 90 degree elbow and 1/2" O.D. tube connection– shank only

• Two vacuum breaker variations– Angled atmospheric vacuum breaker. Brass construction with

durable silicone disc allowing high heat and water hammershock resistance. Provides superior performance when usedwith aspirator assemblies

– Dual check, in-line vacuum breaker resulting in an aboveaverage flow rate and consequently lower pressure loss

Supplied with 90 degree Elbow and 1/2" O.D. Tube Connection (17117 Shank)With Gooseneck

W6350Remote controlled wallmount turret and rigid swivel gooseneck,complete with vandal resistant locking pins, shank, 1/4" I.D. 10 serration nozzle, locknut, lockwasher, elbow and 1/2" ODtube connection.

W6350-9As W6350, but with in-line, dual check vacuum breaker and nozzleWith Angle Vacuum Breaker Spout

W6350-10Remote controlled wallmount turret and rigid/swivel vacuum breaker spout, complete with vandal resistant locking pins, shank,1/4" I.D. 10 serration nozzle, locknut, lockwasher, elbow and1/2" OD tube connection.

W6350-12As W6350-10, but with aspirator (filter pump) having serratedhose-end connection at both suction and discharge ends

Supplied with 17117 Shank Only (Less 90 degree Elbow and 1/2" O.D. TubeConnection)With Gooseneck

W6350-39Remote controlled wallmount turret and rigid/swivel gooseneck,complete with vandal resistant locking pins, shank, 1/4” I.D.10 serration nozzle, locknut, lockwasher with in-line, dual checkvacuum breaker and nozzle

With Angle Vacuum Breaker SpoutW6350-40

Remote controlled wallmount turret and rigid/swivel vacuum breaker spout, complete with vandal resistant locking pins, shank,1/4" I.D. 10 serration nozzle, locknut, lockwasher

W6350-42As W6350-40, but with aspirator (filter pump) having serratedhose-end connection at both suction and discharge ends

W6350

Fume Hood Outlets

DSP–W6350

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Approvals and Standards Met:

In-line Vacuum Breaker tested and approved in conformance withASSE 1035 “Laboratory Faucet Vacuum Breakers”. Listed by IAPMO.CSA certified to B64.7Angle Vacuum Breaker tested and approved in conformance withASSE 1001 and CSA B64.1.1

CSA certified to B125 with compliance to ASME A112.18.1®

W6350-10 _____W6350-40 _____

Note: When product used with potable water it issuggested that plumbing code requirementsfor back-flow prevention be reviewed. See Page 10.7.4 for Vacuum Breakerinformation.

With 90° Elbow and 1/2" O.D. Tube ConnectionLess 90° Elbow and 1/2" O.D. Tube Connection

W6350-9W6350-39

W6350-12W6350-42

Compression Ball Sleeve toslip 1/2" OD tube

FOR COMPLETE ORDERINGINFORMATION INCLUDING

AVAILABLE OPTIONS,SEE PAGE 10.2.2

Note: Measurements may vary ± 6mm (0.25'')

W6350 _____

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Fume Hood Outlets

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.2.6

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

W6381-3C.P wall flange with angled 3.2 mm (1/8") 10 serration nozzle,complete with 3/8" NPS shank, locknut and lockwasher

W6381-3

Fume Hood Outlets

DSP–W6381

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

W6381-3With shank

Note: When product is used with potable water,it is suggested that plumbing code requirementsfor back-flow prevention be reviewed.See Page 10.7.4 for Vacuum Breaker information.

FOR COMPLETE ORDERING INFORMATION INCLUDING AVAILABLE OPTIONS,SEE PAGE 10.2.1

Note: Measurements may vary ± 6mm (0.25'')

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Single Water

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselectonline.com for finish options and product availability. Page 10.3.1

Refer to www.specselectonline.com for individual models. Note: Use this page front and back as a product submittal sheet.

A Use regular catalog pages to determine the product that you are looking for – 10.3.2 to 10.3.3• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

OPTIONAL SPOUTS – OPTIONAL SPOUT MUST BE SAME TYPE AS STD. SPOUT (I.E., REGULAR OR ANGLE VB)

Suffix “A” “C” “L”REGULAR Number mm inches mm inches mm inches

R1 89 3.5 51 2 173 6.8R2 114 4.5 104 4.1 170 6.7R3 152 6.0 124 4.9 56 2.2R4 152 6.0 124 4.9 146 5.8R5 152 6.0 124 4.9 188 7.4R6 152 6.0 124 4.9 229 9R7 229 9.0 163 6.4 170 6.7R8 229 9.0 163 6.4 348 13.7

ANGLE R22 152 6.0 135 5.3 147 5.8VB R23 152 6.0 135 5.3 188 7.4

R24 203 8.0 135 5.3 188 7.4R25 229 9.0 135 5.3 188 7.4R26 305 12.0 135 5.3 188 7.4

A

A

L

L

C

C

X

O

Std. Spout ( )X = Regular

O = Angle VB

EASY ORDER SYSTEM

CATALOG # & FINISH CODE SERVICE CODE OPTION CODES

SERVICE CODES

Service Code

Cold Water (EF)Hot Water HW (EC)

Compression: 100 P.S.I., Max.,180°F Max.

OPTIONAL HANDLES – STD. SHOWN ABOVE

Suffix For Description No. Use On

Black Plastic A All

23/4" Lever Blade C All

4" Blade J All

Green Plastic – Cold Water I All

English Index (CW) no longer required.

(French Index in Brackets)

Catalog No. & Finish Code Two Arm Metal BStandard

CHROME CR Description Handle 23/4" Lever Blade C

W6600 W6600-50 Deckmount compression valve with rigid/swivel gooseneck and nozzle ✓ X (R5)W6600-8 W6600-58 As W6600 but with aerator outlet ✓ X (R5)W6600-9 W6600-59 As W6600 but with in-line vacuum breaker and nozzle ✓ X (R5)W6600-10 W6600-60 As W6600 but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)W6600-12 W6600-62 W6600-10 with 77423 aspirator ✓ O (R23)W6600-C W6600-50-C Deckmount compression valve with rigid/swivel gooseneck and nozzle ✓ X (R5)W6600-8-C W6600-58-C As W6600-C but with aerator outlet ✓ X (R5)W6600-9-C W6600-59-C As W6600-C but with in-line vacuum breaker and nozzle ✓ X (R5)W6600-10-C W6600-60-C As W6600-C but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)W6600-12-C W6600-62-C As W6600-10-C with 77423 aspirator ✓ O (R23))

W6601 W6601-50 Deckmount compression valve for 11⁄2" hole with rigid/swivel gooseneck and nozzle ✓ X (R5)W6601-8 W6601-58 As W6601 but with aerator outlet ✓ X (R5)W6601-9 W6601-59 As W6601 but with in-line vacuum breaker and nozzle ✓ X (R5)W6601-10 W6601-60 As W6601 but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)W6601-12 W6601-62 As W6601-10 but with 77423 aspirator ✓ O (R23)W6601-C W6601-50-C Deckmount compression valve for 11⁄2" hole with rigid/swivel gooseneck and nozzle ✓ X (R5)W6601-8-C W6601-58-C As W6601-C but with aerator outlet ✓ X (R5)W6601-9-C W6601-59-C As W6601-C but with in-line vacuum breaker and nozzle ✓ X (R5)W6601-10-C W6601-60-C As W6601-C but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)W6601-12-C W6601-62-C As W6601-10-C with 77423 aspirator ✓ O (R23)

Single Laboratory Faucet for Water

W6600-10

SINGLE WATER FAUCET FOR UP TO 1 1/4" DIA. HOLE

SINGLE WATER FAUCET FOR UP TO 1 1/2" DIA. HOLE

Valves listed above come standard with the Teck Lab structure (1-3/4 turns to open).Also available as a Special Order with the Cer-Teck 1/4 turn ceramic structure.Also available as Special Order with 120º Limited Swing Gooseneck (W6600 Series Only).Contact Technical Service at 1-800-387-8277 for details.

Single Water Faucets –Deckmount

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.3.2

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• Fits a maximum 1-1/4" diameter hole

(7/8" diameter hole recommended)• Teck® rigid/swivel gooseneck

– unique design permits field installation as a rigid or swivelgooseneck

– heavy-duty gooseneck made from seamless brass pipe• All brass body with vandal resistant locking pin to prevent

damage to counter top (can be removed in field if not required)• Raised lockwasher to provide positive gripping during

installation• Teck® Lab structure • C.P. renewable brass seat• Two handle variations

– 2 arm Teck® Lab handle– ADA compliant 2-3/4" lever blade handle

• Two vacuum breaker variations– Angled atmospheric vacuum breaker. Brass construction with

durable silicone disk allowing high heat and water hammershock resistance. Provides superior performance when usedwith aspirator assemblies

– Dual check in-line vacuum breaker resulting in above average flow rate and consequently lower pressure loss.

• Gooseneck can be oriented to suit left, center, or right handleoperation

2 Arm Lab Handle ProductWith Gooseneck Spout

W6600Deckmount single faucet with rigid/swivel gooseneck completewith vandal resistant locking pin, 1/4" I.D. 10 serration nozzle,shank, locknut, lockwasher, 2 arm lab handle, Teck® Lab structure,C.P. renewable brass seat, 1/4" NPT tailpiece and coupling nut

W6600-8As W6600, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6600-9As W6600, but with in-line dual check vacuum breaker and nozzleWith Angle Vacuum Breaker Spout

W6600-10Deckmount single faucet with rigid/swivel angle vacuum breakerspout, complete with vandal resistant locking pin, 1/4" I.D. 10serration nozzle, shank, locknut, lockwasher, 2 arm lab handle,Teck® Lab structure, C.P. renewable brass seat, 1/4" NPT tailpieceand coupling nut

W6600-12As W6600-10, but with C.P. Aspirator (filter pump) havingserrated hose-end connection at both suction and discharge ends

ADA Compliant 2-3/4" Lever Blade Handle Product With Gooseneck Spout

W6600-C Deckmount single faucet with rigid/swivel gooseneck completewith vandal resistant locking pin, 1/4" I.D. 10 serration nozzle,shank, locknut, lockwasher, ADA compliant 2-3/4" lever bladehandle, Teck® Lab structure, C.P. renewable brass seat, 1/4" NPTtailpiece and coupling nut

W6600-8-C As W6600-C, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6600-9-C As W6600-C, but with in-line dual check vacuum breaker andnozzleWith Angle Vacuum Breaker Spout

W6600-10-C Deckmount single faucet with rigid/swivel angle vacuum breakerspout, complete with vandal resistant locking pin, 1/4" I.D. 10serration nozzle, shank, locknut, lockwasher, ADA compliant 2-3/4" lever blade handle, Teck® Lab structure, C.P. renewablebrass seat, 1/4" NPT tailpiece and coupling nut

W6600-12-C As W6600-10-C, but with C.P. Aspirator (filter pump) having ser-rated hose-end connection at both suction and discharge ends

W6600-9 W6600-10

Single Water Faucets –Deckmount

DSP–W6600

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Approvals and Standards Met:

In-line VB tested and approved in conformance with ASSE 1035“Laboratory Faucet Vacuum Breakers”. Listed by IAPMO. CSA certified to B64.7Angle VB tested and approved in conformance with ASSE 1001and CSA B64.1.1

ADA compliant and meets Handicapped AccessibilityStandard ASME A117.1 of less than 5 lbs. operatingforce when 2-3/4" lever blade handle is used

CSA certified to B125 with compliance to ASME A112.18.1®

W6600-10 (2 Arm – shown)W6600-10-C (Lever)

W6600 (2 Arm – shown)W6600-C (Lever)

FOR COMPLETEORDERING

INFORMATIONINCLUDING

AVAILABLE OPTIONS,SEE Page 10.3.1

46 mm to48 mm(1.83"

- 1.90")DRILL IN

FIELD

46 mm to48 mm(1.83"

- 1.90")DRILL IN

FIELD

Maximum11/4" DiameterShank Hole, 7/8" DiameterRecommended

Note: Measurements may vary ± 6mm (0.25'')

W6600-12(2 Arm)W6600-12-C(Lever)

2-3/4" Lever Blade Handle Product

W6600-8(2 Arm)W6600-8-C(Lever)

W6600-9(2 Arm)W6600-9-C(Lever)

Note: When product is used withpotable water it is suggested thatplumbing code requirements forback-flow prevention be reviewed.See Page 10.7.4 for VacuumBreaker information.

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Features:• Fits a maximum 1-1/2" diameter hole

(1" diameter hole recommended)• Teck® rigid/swivel gooseneck

– unique design permits field installation as a rigid or swivelgooseneck

– heavy-duty gooseneck made from seamless brass pipe• All brass body with deck flange – No Vandal Resistant

Locking Pin• Raised lockwasher to provide positive gripping during

installation• Teck® Lab structure • C.P. renewable brass seat• Two handle variations

– 2 arm Teck® Lab handle– ADA compliant 2-3/4" lever handle

• Two vacuum breaker variations– Angled atmospheric vacuum breaker. Brass construction with

durable silicone disk allowing high heat and water hammershock resistance. Provides superior performance when usedwith aspirator assemblies

– Dual check in-line vacuum breaker resulting in above averageflow rate and consequently lower pressure loss

• Gooseneck can be oriented to suit left, center, or right handleoperation

2 Arm Lab Handle ProductWith Gooseneck Spout

W6601Deckmount single faucet with rigid/swivel gooseneck completewith deck flange, 1/4" I.D. 10 serration nozzle, shank, locknut,lockwasher, 2 arm lab handle, Teck® Lab structure, C.P. renewablebrass seat, 1/4" NPT tailpiece and coupling nut

W6601-8As W6601, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6601-9As W6601, but with in-line dual check vacuum breaker and nozzleWith Angle Vacuum Breaker Spout

W6601-10Deckmount single faucet with rigid/swivel angle vacuum breakerspout, complete with deck flange, 1/4" I.D. 10 serration nozzle,shank, locknut, lockwasher, 2 arm lab handle, Teck® Lab structure,C.P. renewable brass seat, 1/4" NPT tailpiece and coupling nut

W6601-12As W6601-10, but with C.P. Aspirator (filter pump) havingserrated hose-end connection at both suction and discharge ends

ADA Compliant 2-3/4" Lever Blade Handle Product With Gooseneck Spout

W6601-C Deckmount single faucet with rigid/swivel gooseneck completewith deck flange, 1/4" I.D. 10 serration nozzle, shank, locknut,lockwasher, ADA compliant 2-3/4" lever blade handle, Teck® Labstructure, C.P. renewable brass seat, 1/4" NPT tailpiece andcoupling nut

W6601-8-C As W6601-C, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6601-9-C As W6601-C, but with in-line dual check vacuum breaker andnozzleWith Angle Vacuum Breaker Spout

W6601-10-C Deckmount single faucet with rigid/swivel angle vacuum breakerspout, complete with deck flange, 1/4" I.D. 10 serration nozzle,shank, locknut, lockwasher, ADA compliant 2-3/4" lever bladehandle, Teck® Lab structure, C.P. renewable brass seat, 1/4" NPTtailpiece and coupling nut

W6601-12-C As W6601-10-C, but with C.P. Aspirator (filter pump) havingserrated hose-end connection at both suction and discharge ends

W6601-9 W6601-10

Single Water Faucets –Deckmount

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.3.3

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Single Water Faucets –Deckmount

DSP–W6601

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Approvals and Standards Met:

In-line VB tested and approved in conformance with ASSE 1035“Laboratory Faucet Vacuum Breakers”. Listed by IAPMO.CSA certified to B64.7Angle VB tested and approved in conformance with ASSE 1001and CSA B64.1.1

(A) Gooseneck Spout with serrated nozzleW6601 2 arm lab handleW6601-C 2-3/4" lever blade handle (ADA) – shown

(B) Gooseneck Spout with aeratorW6601-8 2 arm lab handleW6601-8-C 2-3/4" lever blade handle (ADA) – shown

(C) Gooseneck Spout with In-line vacuum breaker andserrated nozzle

W6601-9 2 arm lab handleW6601-9-C 2-3/4" lever blade handle (ADA) – shown

(D) Angle Vacuum Breaker Spout with serrated nozzleW6601-10 2 arm lab handleW6601-10-C 2-3/4" lever blade handle (ADA) – shown

(E) Angle Vacuum Breaker Spout with serrated end aspiratorW6601-12 2 arm lab handleW6601-12-C 2-3/4" lever blade handle (ADA) – shown

With Gooseneck Spout (R5) Standard Spout With Angle Vacuum Breaker Spout(R23) Standard Spout

Note: When productis used with potablewater, it is suggestedthat plumbing code requirements forback-flow preventionbe reviewed. SeePage 10.7.4 forVacuum Breakerinformation.

FOR COMPLETEORDERING

INFORMATIONINCLUDING

AVAILABLE OPTIONS, SEE Page 10.3.1

Note: Measurements may vary ± 6mm (0.25'')

“L” DIM.PRODUCT mm Inches

W6601-10-C 232 9.12W6601-12-C 193 7.60

“L” DIM.PRODUCT mm Inches

W6601-C 232 9.12W6601-8-C 259 10.20W6601-9-C 180 7.10

Maximum11/2" DiameterShank Hole, 1" Diameter

Recommended

CSA certified to B125 with compliance to ASME A112.18.1ADA compliant and meets Handicapped AccessibilityStandard ASME A117.1 of less than 5 lbs. operating forcewhen 2-3/4" lever blade handle is used

2 Arm Metal Handle

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Pure Water

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.4.1

Refer to www.specselect.com for individual models.

A Use regular catalog pages to determine the product that you are looking for – 10.4.2• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

Catalog No. & Finish Code

CHROME CR Description

W6629 W6629-50 Celcon control valve for pure water faucetsW6635 W6635-50 Deckmount pure water faucet with combined self-closing and lock-open

Celcon control valve, C.P. rigid gooseneck with tygon liner

Pure Water Faucets

SERVICE CODES

Service Code

Distilled Water DW (ED)De-ionized Water DIDe-mineralized Water DMReverse Osmosis RO

Celcon Control Valve: 60 P.S.I. Max.,180°F Max.

(French Index in brackets)

EASY ORDER SYSTEM

CATALOG # & FINISH CODE SERVICE CODE

Pure Water Faucets

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.4.2

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• Engineered from modern materials to keep distilled water pure.

Celcon control valve is chemically inert to most commonlaboratory chemicals (not hydrochloric or sulphuric acids)

• Life tested to 500,000 cycles. Operates up to 414 kPa (60 psi)line pressure

• Flexible diaphragm seat is moulded to the stem for positiveaction, seal and long life. Valve diaphragm and entirewaterway is inert Tygon material with a Celcon union inletconnection, preventing contact of water with metal components.1/2" M.I.P. size

• Double action spring loaded handle provides self-closing and fulllock-open flow operation

• All goosenecks are heavy-duty 3/8" I.P.S. brass pipe, with inertlining Tygon tubing. Standard goosenecks have 152 mm (6")diameter bend.

• Smooth, glossy chrome plated finish, allows for ease of cleaning• Forged brass turret with vandal resistant locking pins to prevent

damage to mounting surface (can be removed in field if notrequired)

• Raised lockwasher to provide positive gripping duringinstallation

W6635Deckmount pure water faucet complete with W6629 Celcon valvewith 6 serration hose end, Tygon tubing, rigid gooseneck, Celcon1/2" NPT union tail inlet, 1/2" NPS shank, locknut, lockwasher,vandal resistant locking pins

W6629All internal Celcon valve with double action spring loaded handle,complete with 3/8" NPT inlet and 6 serration built-in nozzle

W6635

W6629

Pure Water Faucets

DSP–W6635

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

W6635

Note: The C.R. finish on this product will NOT protect thecelcon valve against damage by strong mineral acids or acidfumes such as sulphuric, nitric and hydrochloric, as well asdirect exposure to UV light.

W6629Celcon Valve for Distilled Water Faucet

FOR COMPLETE ORDERINGINFORMATION INCLUDING

AVAILABLE OPTIONS, SEE PAGE 10.4.1

Note: Measurements may vary ± 6mm (0.25'')

3/8" NPSINDEX BUTTON

W6635 PURE WATER VALVE

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Mixing Faucets

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.5.1

Refer to www.specselect.com for individual models.

Catalog No. & Finish Code Two Arm Metal BStandardCHROME CR Description Handle 23/4" Lever Blade C

W6700 W6700-50 With rigid/swivel gooseneck and nozzle outlet, inlets at 23⁄4" centers ✓ X (R5)W6700-8 W6700-58 As W6700 but with aerator outlet ✓ X (R5)W6700-9 W6700-59 As W6700 but with in-line vacuum breaker and nozzle outlet ✓ X (R5)W6700-10 W6700-60 As W6700 but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)W6700-12 W6700-62 W6700-10 with 77423 aspirator ✓ O (R23)W6700-C W6700-50-C With rigid/swivel gooseneck and nozzle outlet, inlets at 23⁄4" centers ✓ X (R5)W6700-8-C W6700-58-C As W6700-C but with aerator outlet ✓ X (R5)W6700-9-C W6700-59-C As W6700-C but with in-line vacuum breaker and nozzle ✓ X (R5)W6700-10-C W6700-60-C As W6700-C but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)W6700-12-C W6700-62-C As W6700-10-C with 77423 aspirator ✓ O (R23)

W6720 W6720-50 With rigid/swivel gooseneck and nozzle outlet, inlets at 4" centers CAST body ✓ X (R6)W6720-8 W6720-58 As W6720 but with aerator outlet ✓ X (R6)W6720-9 W6720-59 As W6720 but with in-line vacuum breaker and nozzle outlet ✓ X (R6)W6720-10 W6720-60 As W6720 but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)

W6740 W6740-50 Bar deck faucet w/ rigid/swivel gooseneck and nozzle outlet, inlets at 8" centers CAST body ✓ X (R6)W6740-8 W6740-58 As W6740 but with aerator outlet ✓ X (R6)W6740-9 W6740-59 As W6740 but with in-line vacuum breaker and nozzle outlet ✓ X (R6)W6740-10 W6740-60 As W6740 but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle ✓ O (R23)

A Use regular catalog pages to determine the product that you are looking for – 10.5.2 to 10.5.4• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

Deckmount Laboratory Mixing Faucets

W6700-9

OPTIONAL HANDLES – STD. SHOWN ABOVE

Suffix For UseDescription No. On

Black Plastic A All

23/4" Lever Blade C All

4" Blade D All

6" Blade E W6720-W6740

SERVICE CODES

Service Code

Cold Water / Hot Water (EF/EC)

Compression: 100 P.S.I., Max.,180°F Max.

OPTIONAL SPOUTS – OPTIONAL SPOUT MUST BE SAME TYPE AS STD. SPOUT (I.E., REGULAR OR ANGLE VB)

Suffix “A” “C” “L”REGULAR Number mm inches mm inches mm inches

R1 89 3.5 51 2 173 6.8

R2 114 4.5 104 4.1 170 6.7R3 152 6.0 124 4.9 56 2.2R4 152 6.0 124 4.9 146 5.8R5 152 6.0 124 4.9 188 7.4R6 152 6.0 124 4.9 229 9R7 229 9.0 163 6.4 170 6.7R8 229 9.0 163 6.4 348 13.7

ANGLE R22 152 6.0 135 5.3 147 5.8VB R23 152 6.0 135 5.3 188 7.4

R24 203 8.0 135 5.3 188 7.4R25 229 9.0 135 5.3 188 7.4R26 305 12.0 135 5.3 188 7.4

A

A

L

L

C

C

X

O

(French Index in Brackets)

Std. Spout ( )X = Regular

O = Angle VB

English Index (CW/HW)no longer required.

EASY ORDER SYSTEM

CATALOG # & FINISH CODE SERVICE CODE OPTION CODES

MIXING FAUCET WITH 2 3/4" CENTERS

MIXING FAUCET WITH 4" CENTERS

MIXING FAUCET WITH 8" CENTERS

Valves listed above come standard with the Teck Lab structure (1-3/4 turns to open).Also available as a Special Order with the Cer-Teck 1/4 turn ceramic structure.Also available as Special Order with 120º Limited Swing Gooseneck.Contact Technical Service at 1-800-387-8277 for details.

Mixing Faucets – Single Shank

Refer to www.specselect.com for individual models.

A Use regular catalog pages to determine the product that you are looking for – 10.5.2 to 10.5.4• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

Catalog No. & Finish CodeStd. Handle

CHROME CR Description Two Arm Metal

W6760 ––– Single shank mixing with rigid/swivel gooseneck and nozzle outlet X (R5)

W6760-8 ––– As W6760 but with aerator outlet X (R5)

W6760-9 ––– As W6760 but with in-line vacuum breaker and nozzle outlet X (R5)

W6760-10 ––– As W6760 but with W6850 rigid/swivel gooseneck with angle vacuum breaker and nozzle O (R23)

Wallmount Laboratory Mixing Faucets

OPTIONAL HANDLES – STD. SHOWN ABOVE

Suffix For UseDescription No. On

Black Plastic A All

SERVICE CODES

Service Code

Cold Water / Hot Water (EF/EC)

Compression: 100 P.S.I., Max.,180°F Max.

OPTIONAL SPOUTS – OPTIONAL SPOUT MUST BE SAME TYPE AS STD. SPOUT (I.E., REGULAR OR ANGLE VB)

Suffix “A” “C” “L”REGULAR Number mm inches mm inches mm inches

R1 89 3.5 51 2 173 6.8R2 114 4.5 104 4.1 170 6.7R3 152 6.0 124 4.9 56 2.2R4 152 6.0 124 4.9 146 5.8R5 152 6.0 124 4.9 188 7.4R6 152 6.0 124 4.9 229 9R7 229 9.0 163 6.4 170 6.7R8 229 9.0 163 6.4 348 13.7

ANGLE R22 152 6.0 135 5.3 147 5.8VB R23 152 6.0 135 5.3 188 7.4

R24 203 8.0 135 5.3 188 7.4R25 229 9.0 135 5.3 188 7.4R26 305 12.0 135 5.3 188 7.4

A

A

L

L

C

C

X

O

(French Index in Brackets)

Std. Spout ( )X = Regular

O = Angle VB

English Index (CW/HW)no longer required.

EASY ORDER SYSTEM

CATALOG # & FINISH CODE SERVICE CODE OPTION CODES

W6760-9 Valves listed above come standard with the Teck Lab structure (1-3/4 turns to open).Also available as a Special Order with the Cer-Teck 1/4 turn ceramic structure.Also available as Special Order with 120º Limited Swing Gooseneck.Contact Technical Service at 1-800-387-8277 for details.

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Mixing Faucets – Deckmount

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.5.2

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• Fits a maximum 1-1/4" diameter holes

(7/8" diameter holes recommended)• Teck® rigid/swivel gooseneck

– unique design permits field installation as a rigid or swivelgooseneck

– heavy-duty gooseneck made from seamless brass pipe• All brass body with vandal resistant dual shanks to prevent

damage to counter top• Raised lockwasher to provide positive gripping during

installation• Teck® Lab structure • C.P. renewable brass seat• Two handle variations

– 2 arm Teck® Lab handle– ADA compliant 2-3/4" lever blade handle

• Two vacuum breaker variations– Angled atmospheric vacuum breaker. Brass construction with

durable silicone disk allowing high heat and water hammershock resistance. Provides superior performance when usedwith aspirator assemblies

– Dual check in-line vacuum breaker resulting in above averageflow rate and consequently lower pressure loss

2 Arm Lab Handle ProductWith Gooseneck Spout

W6700Deckmount mixing faucet with rigid/swivel gooseneck completewith 1/4" I.D. 10 serration nozzle, dual shanks, locknuts,lockwashers, 2 arm lab handles, Teck® Lab structures, C.P.renewable brass seats, 1/4" NPT tailpiece and coupling nuts

W6700-8 As W6700, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6700-9 As W6700, but with in-line dual check vacuum breaker and nozzleWith Angle Vacuum Breaker Spout

W6700-10 Deckmount mixing faucet with rigid/swivel angle vacuum breakerspout, complete with 1/4" I.D. 10 serration nozzle, dual shanks,locknuts, lockwashers, 2 arm lab handles, Teck® Lab structures, C.P. renewable brass seats, 1/4" NPT tailpiece and coupling nuts

W6700-12 As W6700-10, but with C.P. Aspirator (filter pump) having serratedhose-end connection at both suction and discharge ends

ADA Compliant2-3/4" Lever Blade Handle Product With Gooseneck Spout

W6700-C Deckmount mixing faucet with rigid/swivel gooseneck completewith 1/4" I.D. 10 serration nozzle, dual shanks, locknuts,lockwashers, ADA compliant 2-3/4" lever blade handles, Teck®

Lab structures, C.P. renewable brass seats, 1/4" NPT tailpieceand coupling nuts

W6700-8-C As W6700-C, but with 2.2 USGPM (8.3 L/min.) flow controlaerator

W6700-9-C As W6700-C, but with in-line dual check vacuum breaker andnozzleWith Angle Vacuum Breaker Spout

W6700-10-C Deckmount mixing faucet with rigid/swivel angle vacuum breakerspout, complete with 1/4" I.D. 10 serration nozzle, dual shanks,locknuts, lockwashers, ADA compliant 2-3/4" lever blade handles,Teck® Lab structures, C.P. renewable brass seats, 1/4" NPTtailpiece and coupling nuts

W6700-12-C As W6700-10-C, but with C.P. Aspirator (filter pump) havingserrated hose-end connection at both suction and discharge ends

W6700-9 W6700-12

Mixing Faucets – Deckmount

DSP–W6700

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

W6700 (2 Arm – shown)W6700-C (Lever)

W6700-8 (2 Arm)W6700-8-C (Lever)

W6700-9 (2 Arm)W6700-9-C (Lever)

W6700-10 (2 Arm – shown)W6700-10-C (Lever)

2-3/4" Lever Blade Handle Product

Approvals and Standards Met:

In-line VB tested and approved in conformance with ASSE 1035“Laboratory Faucet Vacuum Breakers”. Listed by IAPMO.CSA certified to B64.7Angle VB tested and approved in conformance with ASSE 1001and CSA B64.1.1

ADA compliant and meets Handicapped AccessiblityStandard ASME A117.1 of less than 5 lbs. operatingforce when 2-3/4" lever blade handle is used

CSA certified to B125 with compliance to ASME A112.18.1®

Note: When product is used with potable water, it issuggested that plumbing coderequirements for back-flowprevention be reviewed. See Page 10.7.4 forVacuum Breakerinformation.

W6700-12 (2 Arm)W6700-12-C (Lever)

FOR COMPLETE ORDERINGINFORMATION INCLUDING

AVAILABLE OPTIONS,SEE PAGE 10.5.1

Note: Measurements may vary ± 6mm (0.25'')

Maximum11/4" DiameterShank Holes, 7/8" DiameterRecommended

70mm(2.75")

96mm(3.75")

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Mixing Faucets – Cast Brass Deckmount

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.5.3

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• Teck® rigid/swivel gooseneck

– unique design permits field installation as a rigid or swivelgooseneck

– heavy-duty gooseneck made from seamless brass pipe• Chrome plated CAST BRASS BODY• 2 arm Teck® lab handles standard• Teck® Lab structures • C.P. renewable brass seats• Two vacuum breaker variations

– Angled atmospheric vacuum breaker. Brass construction withdurable silicone disk allowing high heat and water hammershock resistance. Provides superior performance when usedwith aspirator assemblies

– Dual check in-line vacuum breaker resulting in an aboveaverage flow rate and consequently lower pressure loss

4" CentresW6720

Deckmount mixing faucet with rigid/swivel gooseneck completewith 1/4" I.D. 10 serration nozzle, 1/2" NPS shanks, inlets at102 mm (4") centres, chrome plated CAST BRASS BODY, locknuts,lockwashers, 1/4" NPT tailpiece and coupling nuts, 2 arm labhandles, Teck® Lab structures, C.P. renewable brass seats

W6720-8As W6720, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6720-9As W6720, but with in-line dual check vacuum breaker andnozzle

W6720-10As W6720, but with angle vacuum breaker spout and nozzle

8" CentresW6740

Deckmount mixing faucet with rigid/swivel gooseneck completewith 1/4" I.D. 10 serration nozzle, 1/2" NPS shanks, inlets at203 mm (8") centres, chrome plated CAST BRASS BODY, locknuts,lockwashers, 1/4" NPT tailpiece and coupling nuts, 2 arm labhandles, Teck® Lab structures, C.P. renewable brass seats

W6740-8As W6740, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6740-9As W6740, but with in-line dual check vacuum breaker andnozzle

W6740-10As W6740, but with angle vacuum breaker spout and nozzle

W6720

W6740

Mixing Faucets –Cast Brass Deckmount

DSP–W6720

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

W6720

FOR COMPLETE ORDERINGINFORMATION INCLUDING

AVAILABLE OPTIONS,SEE PAGE 10.5.1

Note: Measurements may vary ± 6mm (0.25'')

W6720-9

W6720-8

Optional VB Spout (W6850) specify:

W6720-10W6740-10

336mm (13.2")

152mm (6.0")

160mm (6.3")

Approvals and Standards Met:

In-line VB tested and approved in conformance with ASSE 1035“Laboratory Faucet Vacuum Breakers”. Listed by IAPMO.CSA certified to B64.7Angle VB tested and approved in conformance with ASSE 1001and CSA B64.1.1

CSA certified to B125 with compliance to ASME A112.18.1ADA compliant and meets Handicapped AccessiblityStandard ASME A117.1 of less than 5 lbs. operating forcewhen optional lever blade or blade handles are specified

Faucet Inlets:For 3/8" or 1/2" flexible riseror 1/2"-14 NPSM Coupling Nut (Supplied)or 1/4" MIP Tail (Supplied)

Note:1.When 77423 filter pump assembly and back-

flow prevention are required, it is recommendedthat optional W6850 VB spout be specified.

2. When product is used with potable water, it issuggested that plumbing code requirements forback-flow prevention be reviewed.

See Page 10.7.4 for Vacuum Breakerinformation.

W6740_____W6740-9

W6740-8

238mm(9.4")

161mm(6.3")

238mm(9.4")

161mm(6.3")

DECK

DECK

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Mixing Faucets – Single Shank

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.5.4

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Features:• Teck® rigid/swivel gooseneck

– unique design permits field installation as a rigid or swivelgooseneck

– heavy-duty gooseneck made from seamless brass pipe• All brass body with vandal reistant anti-rotation locking pins

to prevent damage to counter top (can be removed in field ifnot required)

• Teck® Lab structures • C.P. renewable brass seats• 2 arm Teck® lab handles standard• Two vacuum breaker variations

– Angled atmospheric vacuum breaker. Brass construction withdurable silicone disk allowing high heat and water hammershock resistance. Provides superior performance when usedwith aspirator assemblies

– Dual check in-line vacuum breaker resulting in an aboveaverage flow rate and consequently lower pressure loss

2 Arm Lab Handle ProductWith Gooseneck Spout

W6760Single Shank mixing faucet with rigid/swivel gooseneck completewith 1/4” I.D. 10 serration nozzle, locknuts, 2 arm lab handles,Teck® Lab structures, C.P. renewable brass seats, S/S flexible hoses,3/8” compression connection

W6760-8As W6760, but with 2.2 USGPM (8.3 L/min.) flow control aerator

W6760-9As W6760, but with in-line dual check vacuum breaker and nozzle

With Angle Vacuum Breaker SpoutW6760-10

Single Shank mixing faucet with rigid/swivel vacuum breakerspout, complete with 1/4” I.D. 10 serration nozzle, locknuts, 2 armlab handles, Teck® Lab structures, C.P. renewable brass seats, S/Sflexible hoses, 3/8” compression connection

W6760-9

Mixing Faucets – Single Shank

DSP–W6760

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

403mm (15.8")

203mm (8.0")

108mm (4.25")

234mm (9.2")

152mm (6.0")

W6760 W6760-10

Approvals and Standards Met:

In-line VB tested and approved in conformance with ASSE 1035“Laboratory Faucet Vacuum Breakers”. Listed by IAPMO.CSA certified to B64.7Angle VB tested and approved in conformance with ASSE 1001and CSA B64.1.1

CSA certified to B125 with compliance to ASME A112.18.1®

Note: When productis used with potablewater, it is suggestedthat plumbing coderequirements forback-flow preventionbe reviewed. SeePage 10.7.4 forVacuum Breakerinformation.

FOR COMPLETE ORDERINGINFORMATION INCLUDING

AVAILABLE OPTIONS,SEE PAGE 10.5.2

Note: Measurements may vary ± 6mm (0.25'')

Maximum1.5" Diameter

Hole, 1.25" DiameterRecommended

W6760-9

W6760-8

258mm(10.1")

182mm(7.1")

DECK

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Dual Service Faucets

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.6.1

Refer to www.specselect.com for individual models.

A Use regular catalog pages to determine the product that you are looking for – 10.6.2• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

SERVICE CODES

Service Code

Air AIRArgon ACarbon Dioxide CO2Cold Water CW (EF)Helium HEHydrogen H

Service Code

Natural Gas GAS (GAZ)Nitrogen NPropane PROVacuum VAC (VIDE)

Ball Valve: 100 P.S.I. Max. (Gases)60 P.S.I. Max. (Cold Water)

180°F Max.(French Index shown in brackets)

EASY ORDER SYSTEM

CATALOG # & FINISH CODE SERVICE CODES - 2 REQUIRED (Alphabetical Order)

Catalog No. & Finish Code

CHROME CR Description

W6805 W6805-50 Deckmount, 2 ball valve hose cocks @ 90 degrees

Dual Service Laboratory Faucets

Dual Service – Turret Mount

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.6.2

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

NaturalGas/ Cold Hot Carbon

Propane Vacuum Air Nitrogen Argon Hydrogen Oxygen Steam Water Water Helium Dioxide Other Services

Ball Valves – with nozzles Y Y Y Y Y Y N N Y3 N Y Y

VALVE TYPE

Check withTechnicalService

SERVICE

Y = Yes N = No Y3 = Yes, up to 60 psi

Features:Ball Valves: • Floating ball design• Vandal resistant handle • Check valve to prevent contamination of service lines• Vandal resistant 10 serration nozzle• Rated to maximum 125 psi testing pressure• Meets ADA prescribed maximum 5 lb. turning force• Life cycle tested to 100,000 cyclesGeneral:• Forged Brass turret with dual shank inlets

– Each inlet supplies 1 hose cock• Undermount base plate for securing to mounting surface

W6805Deckmount dual service turret with 2 ball valve hose cocks at90 degrees, complete with dual shank inlets at 30mm (1 3/16")centres, locknuts, undermount base plate, 1/4" NPT tailpiecesand coupling nuts.

W6805

Dual Service – Turret Mount

DSP–W6805

Refer to www.specselect.com or individual models. Note: Use this page front and back as a product submittal sheet.

Approvals and Standards Met:CSA approved and tested to ANSI Z21.15,CAN/CGA – 3.16-M88 for use with natural andpropane gases.ADA compliant and meets Handicapped AccessibilityStandard ASME A117.1 of less than 5 lbs. operatingforce when Lever Handle is used.

W6805 ____

Turret – Top View

FOR COMPLETE ORDERINGINFORMATION INCLUDING

AVAILABLE OPTIONS, SEE PAGE 10.6.1

Note: Measurements may vary ± 6mm (0.25'')

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Options and Accessories

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. DDSP–LabSpt Page 10.7.1

Refer to www.specselect.com for individual models.

A Use regular catalog pages to determine the product that you are looking for – 10.7.2 to 10.7.8• Full specification and dimensional drawings

B Use this page to determine –• Model number to order (including finish code, service code, and factory available option suffixes)

Catalog No. & Finish CodeAdd-On

CHROME CR GREEN Suffix #

W6850 W6850-50 W6850GR 152 6.0 173 6.8 137 5.4 R23

W6850-1 W6850-51 W6850-1GR 152 6.0 173 6.8 97 3.8 R22

W6850-8 W6850-58 W6850-8GR 203 8.0 173 6.8 137 5.4 R24

W6850-9 W6850-59 W6850-9GR 229 9.0 173 6.8 137 5.4 R25

W6850-12 W6850-62 W6850-12GR 305 12.0 173 6.8 137 5.4 R26

Teck® Laboratory Special Replacement Angle VB Goosenecks (Separate Orders)

“A”mm inches

“C”mm inches

“L”mm inches

A

L

C

EASY ORDER SYSTEM

CATALOG # & FINISH CODE

ANGLE VB

Catalog No. & Finish Code

Add-OnCHROME CR GREEN Suffix #

W6890-6 W6890-56 W6890-6GR 89 3.5 51 2 173 6.8 R1

W6890-1 W6890-51 W6890-1GR 114 4.5 104 4.1 170 6.7 R2

W6890-7 W6890-57 W6890-7GR 152 6.0 124 4.9 56 2.2 R3

W6890-2 W6890-52 W6890-2GR 152 6.0 124 4.9 146 5.8 R4

W6890 W6890-50 W6890GR 152 6.0 124 4.9 188 7.4 R5

W6890-4 W6890-54 W6890-4GR 152 6.0 124 4.9 229 9 R6

W6890-5 W6890-55 W6890-5GR 229 9.0 163 6.4 170 6.7 R7

W6890-8 W6890-58 W6890-8GR 229 9.0 163 6.4 348 13.7 R8

Teck® Laboratory Special Replacement Rigid/Swivel Goosenecks (Separate Orders)

“A”mm inches

“C”mm inches

“L”mm inches

EASY ORDER SYSTEM

CATALOG # & FINISH CODE

REGULAR

A

L

C

W6890 C.P. rigid/swivel gooseneck, 3/8" M.I.P. inlet connection,3/8" M.I.P. outlet connection. Includes GN spout adaptor. Outlet must be ordered separatelyW6850 C.P. angle vacuum breaker spout assembly featuring Teck®

rigid/swivel connection and 6.4 mm (1/4") nozzle. Includes GN spout adaptor. Faucets with W6850 spout can be specifiedusing “-10” after base faucet number (i.e., W6600 becomesW6600-10)

W6890 W6850

Optional Sizes:•W6890 style

See selection chart Page 10.7.1W6890-6 3.5" RadiusW6890-1 4.5" RadiusW6890-7 6" RadiusW6890-2 6" RadiusW6890 6" RadiusW6890-4 6" RadiusW6890-5 9" RadiusW6890-8 9" Radius

Optional Sizes:•W6850 style

See selection chart Page 10.7.1W6850 6" RadiusW6850-1 6" RadiusW6850-8 8" RadiusW6850-9 9" RadiusW6850-12 12" Radius

W6890Rigid/Swivel Gooseneck Spout

W6850Rigid/Swivel Vacuum Breaker Spout

FOR COMPLETE ORDERINGINFORMATION INCLUDING AVAILABLE

OPTIONS, SEE PAGE 10.7.1

Note: Measurements may vary ± 6mm (0.25'')

Rigid/Swivel Spouts

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.7.2

Refer to www.specselect.com for individual models. Note: Use this page as a product submittal sheet.

Gooseneck Sizing Selection

DSP–LabSpt A

Refer to www.specselect.com for individual models.

Standard Gooseneck Spouts ReferenceDimensions

Spout “A” “C” “L” Spout Add OnNumber mm inches mm inches mm inches Figure No. SuffixW6890-6 89 3.5 51 2 173 6.8 1 R1W6890-1 114 4.5 104 4.1 170 6.7 2 R2W6890-7 152 6 124 4.9 56 2.2 2 R3W6890-2 152 6 124 4.9 146 5.8 2 R4W6890 152 6 124 4.9 188 7.4 2 R5W6890-4 152 6 124 4.9 229 9 2 R6W6890-5 229 9 163 6.4 170 6.7 2 R7W6890-8 229 9 163 6.4 348 13.7 2 R8

Table 1Teck Laboratory & Institutional Rigid/Swivel Goosenecks

Table 2“M” Dimension Chart – Teck Laboratory/Institutional

W6350W6720W6740

W6601W6760

W6600W6700

100

75

50

25

0

4

3

2

1

0

DIM

ENSI

ON

“M

” (m

m)

DIM

ENSI

ON

“M

” (in

ches

)

Spout – Figure 189 mm (3.5") “A” Dim. Gooseneck

Spout – Figure 2All Other Goosenecks

Note: Measurements may vary ± 6mm (0.25'')

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Gooseneck Sizing Selection

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.7.3

Refer to www.specselect.com for individual models.

Spout Outlet Clearance Calculation GuideExample: W6600-9 with vacuum breaker and nozzle – additional clearance required (present clearance is 6.3" with R5 W6890 Spout)

“L” “M” “N” Spout OutletBottom end of Clearance toSpout to Deck Deck or

Spout Spout “L” or Centerline Length of CenterlineExample Selected Dimension of Inlet Spout Outlet of Inlet

Table 1 Table 1 Table 2 “L”+“M” Table 3 or 4 “L”+“M” –“N”1 W6890-8 (R8) 13.7" 2.7" 16.4" 3.9" 12.5"

25

50

75

100

0

1

2

3

4

DIM

ENSI

ON

“N

” (in

ches

)

VACUUM BREAKERAND NOZZLE

NOZZLE

AERATORS– STANDARD– VANDAL PROOF

ROSE SPRAY

Table 3Spout Outlets – Dimension “N”

25

50

75

100

0

1

2

3

4VACUUM BREAKER

AND NOZZLE

NOZZLE

AERATORS– STANDARD– VANDAL PROOF

ROSE SPRAY

Table 4Spout Outlets – Dimension “N”

DIM

ENSI

ON

“N

” (m

m)

DIM

ENSI

ON

“N

” (m

m)

DIM

ENSI

ON

“N

” (in

ches

)

Note: Measurements may vary ± 6mm (0.25'')

Serrated Nozzles

DSP–LabSpt B

Refer to www.specselect.com for individual models.

060500A T3731

180079A 77340 17260-1

Note: Measurements may vary ± 6mm (0.25'')

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

In-Line StyleT1913 (Special Use Only)

C.P. In-line dual check vacuum breaker, 3/8" M.I.P. inlet,3/8" F.I.P. outlet

77076 (Used for -9 Models)C.P. In-line dual check vacuum breaker, 3/8" F.I.P. inlet and 3/8"M.I.P. outlet. This model is provided as standard with “-9” faucetseries

Purpose:To prevent back-siphonage of contaminated water into a potablewater supply. These devices are NOT to be used under continuouspressure (ie., There cannot be a downstream shutoff valve).

Features:• Dual check preventing discharge of waste water if primary

check fails• Vandal resistant• Above average flow rates and lower pressure losses• Brass construction

70327 (Special Use Only)C.P. In-line dual check vacuum breaker, 3/8" F.I.P. inlet and outlet

Purpose:To prevent back-siphonage of contaminated water into a potablewater supply. This device CAN be used under continuous orintermittent pressure (ie., There can be a downstream shutoff valveand the outlet of the hose can be used above the vacuum breaker).

Features:• Dual check preventing discharge of waste water if primary

check fails• Vandal resistant• Above average flow rates and lower pressure losses• Brass construction

Atmospheric StyleT1295 (Used for -10 and -12 Models)

C.P. atmospheric vacuum breaker with 3/8" F.I.P. inlet and outlet.This model is provided as standard with “-10” faucet series

Purpose:To prevent back-siphonage of contaminated water into a potablewater supply. This device is NOT to be used under continuouspressure (ie., There cannot be a downstream shutoff valve), orwhere there is a possiblity that a back pressure condition maydevelop (ie., The vacuum breaker must always be at least 6" abovethe highest point of the outlet of the attached hose).

Features:• Ideally recommended for low flow installations such as

laboratory equipment which use a small amount of water• Lightweight disk assembly prevents spilling under all rates of

flow• Single check• Durable silicone disk allowing high heat and water hammer

shock resistance• Provides superior performance when used with aspirator

assemblies• Brass construction

77076T1295

Vacuum Breakers

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.7.4

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Vacuum Breakers

DSP–VB

Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.

Approvals and Standards Met:®

T1913In-line dual check vacuum breaker

77076In-line dual check vacuum breaker

70327In-line dual check vacuum breaker (continuous pressure applications)

T1295Atmospheric vacuum breaker

Atmospheric: In-Line:

In-line: T1913/77076 CSA certified toB64.7 with compliance to ASSE 1035

70327 CSA certified to B64.8 withcompliance to ASSE 1035

Atmospheric: T1295 CSA certified toB64.1.1 with compliance to ASSE 1001

Note: Measurements may vary ± 6mm (0.25'')

Note: All vacuum breakers require regular maintenance,cleaning, and servicing to ensure proper performance. To obtain internal repair parts for the above, contact WattsRegulator with the Watts model numbers shown below.

Watts #T1913 3/8 NLF9T1295 3/8 288A70327 3/8 N977076 3/8 NLF9R

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Features:• Adjusting faucet flow rates give close control of vacuum drawn

through entire range (to within 25 mm (1") of mercury)• All brass construction• High polish C.P. finish

77422Aspirator with 3/8" F.I.P. inlet, splash diffuser at discharge port,serrated hose-end connection at suction port. 77423Aspirator with 3/8" F.I.P. inlet, both suction and discharge portshave serrated hose-end connection. This model is provided, alongwith VB spout, with “-12” faucet series

77422

77423

77422Filter pump with diffuser

77423Filter pump

Note: Measurements may vary ± 6mm (0.25'')

Aspirators (Filter Pumps)

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.7.5

Refer to www.specselect.com for individual models.

W6870

W6873

Balance Bar Rod and Base

DSP–77423

Refer to www.specselect.com for individual models.

Note: Measurements may vary ± 6mm (0.25'')

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Spout Outlets

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.7.6

Refer to www.specselect.com for individual models.

060257AHose End

W6878Flow control aerator

T3265Adaptor

70429Adaptor

77158Vandal resistant flow control aerator

77142Flow control aerator

Note: Measurements may vary ± 6mm (0.25'')

Connection Fittings

DSP–Outlet

Refer to www.specselect.com for individual models.

ShanksT2714A-1 to T2714A-8

T2714-1 Only

Standard 3/8" Shanks and Options

X YPart No. mm inch mm inch

T2714A-1 113 4.44 80 3.1317117 103 4.06 84 3.31T2714A-2 83 3.25 65 2.56T2714A-3 60 2.38 44 1.75T2714A-4 46 1.81 32 1.25T2714A-7 70 2.75 56 2.19T2714A-8 33 1.31 19 0.74T2714-1 113 4.44 80 3.13060501A 51 2.00 36 1.43060502A 76 3.00 62 2.43

LengthPart No. mm inch

T3009-31 25 1T3009-32 38 1.5T3009-33 51 2T3009-34 64 2.5T3009-35 76 3T3009-36 89 3.5

LengthPart No. mm inch

T3009-37 102 4T3009-39 127 5T3009-40 140 5.5T3009-46 165 6.5

Chrome Plated Brass Nipples3/8" I.P.S., threaded both ends

Note: Measurements may vary ± 6mm (0.25'')

PART NUMBER 17117 T2714-1 T2714A-1 T2714A-2 T2714A-3 T2714A-4 T2714A-7 T2714A-8 060501A 060502AOVERALL LENGTH (4.06") (4.44") (4.44") (3.25") (2.38") (1.81") (2.75") (1.31") (2.0") (3.0")SERIES Suffix W — Suffix L Suffix M Suffix N Suffix P Suffix U Suffix V Suffix Q Suffix T

W6210-W6228 2.46 2.84* 1.65 1.15 1.40

W6270-W6279 3.56 3.94 2.75 1.88* 1.31 2.25 .81 1.50 2.50

W6350 2.46* 2.84 1.65 1.15 1.40

W6381 3.56 3.94 2.75 1.88 1.31 2.25* .81 1.50 2.50EXPO

SED

LEN

GTH

*Standard Shank Supplied (no suffix required)

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.

Connectors

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.7.7

Refer to www.specselect.com for individual models.

Note: Measurements may vary ± 6mm (0.25'')

180001AAdaptor for 1/2" OD tube connection

77052Elbow Connector (shown)30365 3/8" Elbow only (machined)30365-13/8" Elbow only – chrome plated

W6916 C.P. flange and 3/8" F.I.P. coupling

171043/8" F.I.P. coupling only

Brass Collar

060199ARigid/Swivel Collar Pkg.

30366-1C.P. 3/8" F.I.P. Tee

Polypropylene Collar

180002ANut & Washer for 3/8" Shank180064ANut & Washer for 1/2" Shank with tail

180003A1/4" I.P. tail and coupling nut for 3/8" NPS shank

180004A1/4" I.P. tail and coupling nut for 1/2" NPS shank

180005ABall sleeve and coupling nut to slip 1/2" O.D. tube

Turrets

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.DSP–Conn

Refer to www.specselect.com for individual models.

Note: All tapped holes for 3/8" NPT

T1340-1Tapped one side

T1340-2Tapped two sides at 90°

T1340-5Tapped two sides at 180°

Note: Measurements may vary ± 6mm (0.25'')

Structures

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability. Page 10.7.8

Refer to www.specselect.com for individual models.

060144A12 pieces ofCompression/NeedleCP renewable brassseat (replaces 17166and W16500renewable seat)

060443ALong Renewable Seat

W6980Compression structure (to 1977)

77171-1Celcon NeedleStructure(replaces 77063-1needle structure)

060047A Teck® Lab CompressionStructure (RH) and renewableseat (replaces W6991)060048A Teck® Lab CompressionStructure (LH) andrenewable seat

180055A (for W6303 only)Stainless Steel Needlestructure and long seat

Features:• Self-centering needle cone• Excellent functionality at both

hot & cold extremes• Brass renewable seat

180099BShort Renewable Seat

060060ARH C.P. brass Tuf-Teckstructure with renewable seat060061ALH C.P. brass Tuf-Teckstructure with renewable seat

Features:• Threads engaged at all times

for long life• Threads are permanently

lubricated and outside thewaterway, eliminating threadseizing

• Nickel-chrome plated brasscapnut resists corrosion

• Gasket seal fully encased• Double BUNA N neoprene

‘O’ ring seals• Stainless Steel seat washer

screw• Nickel-chrome plated

renewable brass seat• Heavy-duty stem for extra

strength, long life, andmaximum corrosion resistance

• Supplied as standard with76405-1 & 76406-1

Features:• Superior flow control• Celcon needle is easily

replaceable• Stainless Steel seat

washer screw

Features:• Life tested to

500,000 cycles• Stem threads are

permanently lubricatedand outside thewaterway, eliminatingthread seizing

• Stainless Steel seatwasher screw

• Nickel chrome platedrenewable brass seat

Note: Measurements may vary ± 6mm (0.25'')

Optional Handles

Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.DSP–Struct

Refer to www.specselect.com for individual models.

Features:• Sani-guard required along with

Tuf-Teck structure when either76406-1 or 76405-1 isspecified (2 per pack)

Lab HandlesW6968_____Standard black plastic handle, screw

W6971_____2 arm Teck® handle and screw

Institutional Handles

• Coloured plastic handle, screw and index180056A – GAS (blue) 180059A – VAC (yellow)180058A – AIR (orange) 180060A – CW (green)

T1278 SeriesPlastic index button (see pg 10.ii for complete model numbers)

T3899Plain chrome plated button (no index)W6973C.P. Button with custom index (max. 3 letters/numbers stamped on button)

060046A2-3/4" lever blade handle withscrew, red & blue index

060050A5-fluted handle with screw, red& blue index

Features:• Requires less then 5 lbs. to operate• Single handle per pack

Features:• Single handle per pack

76406-1

Features:• 6" wrist handle with screw, red & blue index• Requires less than 5 lbs. to operate• Single handle per pack• Requires 060037A saniguard (2 per pack)

76405-1

Features:• 4" wrist handle with screw,

red & blue index• Requires less than 5 lbs. to

operate• Requires 060037A Sani-guard

(2 per pack)• Single handle per pack

060037A

Note: Measurements may vary ± 6mm (0.25'')