generator l m n p q r s t u v w y · pdf filegenerator connector ... conmed 4 metre cable...
TRANSCRIPT
Symbols: Products on this pageare Autoclavable and Latex Free
ELECTROSURGERY RE-USABLE SPECIALIST BIPOLAR CABLES 16
For P
rima
bipo
lar f
orce
ps
GENERATOR CONNECTOR
L12 M12 S12 T12 Y12U12 V12 W12
L14 M14 N14 P14 Q14 R14 S14 T14 Y14U14 V14 W14
L15 M15 N15 P15 Q15 R15 S15 T15 Y15U15 V15 W15
L16 M16 N16 P16 Q16 R16 S16 T16 Y16U16 V16 W16
L17 M17 N17 P17 Q17 R17 S17 T17 Y17U17 V17 W17
L20 M20 N20 P20 Q20 R20 S20 T20 Y20U20 V20 W20
L22 M22 N22 P22 Q22 R22 S22 T22 Y22U22 V22 W22
Conmed* Dolley, EMC* Coa Comp, Olympus, Soring*
Erbe, Siemens, Sutter BM50
Aesculap, Berschtold,Martin, Sutter BM780, Wolf
Older Eschmann 300 Series (Lemo)
Twin 4 mm Pin, Erbe Int.,Eschmann, Alsa MCD Series
Aesculap (Older Models GK50)
Storz Bowa, EMC, Erbe Int.Ethicon, Lamidey, Valleylab*
Codman CMC11 Valleylab (autobipolar models only)
European Fitting
Karl Storz
R. Wolf
USA Twin Pin
Aesculap (Old Style)
Storz/ Spectrum (Small Fischer Plug)
Ethicon Scissors Bipolar
STANDARD CABLES ARE 3 METRES LONG. TO ORDER 5 METRE LENGTH - SIMPLY ADD ‘/5’ TO THE PRODUCT CODE (E.G. B1/5)
INSTRUMENTCONNECTOR
L M N P Q R S T U V W Y
12
14
15
16
17
20
22
P12 Q12 R12N12
UNIVERSALB I P O L A R C A B L E
17 ELECTROSURGERY RE-USABLE UNIVERSAL BIPOLAR CABLES
Symbols: Products on this pageare Autoclavable and Latex Free
Product Code
L-30
Conmed
4 metrecable
Product Code
M-30
DolleyEMC
4 metrecable
Product Code
N-30
CoacompOlympusSoring
4 metrecable
Product Code
P-30
ErbeSiemens
SutterBM50
4 metrecable
Product Code
Q-30
Aesculap,Berchtold,
Martin,Sutter
BM780,Wolf
4 metrecable
Product Code
R-30
OlderEschmann 300 series
(Lemo)
4 metrecable
Product Code
S-30
Twin 4mmpin, Erbe
International,Eschmann,
US standard,Alsa MCD
series
4 metrecable
Product Code
T-30
Aesculap(older
modelsGK 50)
4 metrecable
Product Code
U-30
Storz
4 metrecable
Product Code
V-30
ValleylabBowa, EMC,
ErbeInternational,
Ethicon, Lamidey
4 metrecable
Product Code
W-30
CodmanCMC 11
4 metrecable
Product Code
Y-30
Valleylab(autobipolar models only)
4 metrecable
• round section wipe clean cable
• double insulated
• fully autoclavable
ELECTROSURGERY RE-USABLE UNIVERSAL BIPOLAR CABLES 18
Patent pending
Symbols: Products on this pageare Autoclavable and Latex Free
www
19 ELECTROSURGERY RE-USABLE BIPOLAR FORCEPS
+44 (0) 1453 756750
+44 (0) 1453 752626
www.prima-medical.com
RE-USABLE BIPOLAR FORCEPS
1 McPherson, 10.2 cm, (0.25 mm tip or 0.45 mm tip) Pack 1 100-025 or 100-0452 McPherson, angled 10.2 cm, (0.25 mm tip or 0.45 mm tip) Pack 1 102-025 or 100-0453 Jeweller 5, 11.5 cm, (0.25 mm tip or 0.60 mm tip) Pack 1 110-025 or 100- 0604 Jeweller 5, 11.5 cm, (0.25 mm tip or 0.60 mm tip) Pack 1 112-025 or 100-0605 Jeweller 7, angled 11.5 cm, (0.25 mm tip or 0.60 mm tip) Pack 1 115-025 or 100-060
1
2
3
4
5
Symbols: Products on this pageare Autoclavable and Latex Free
ELECTROSURGERY RE-USABLE BIPOLAR FORCEPS 20
6 Adson, 12 cm (0.50 mm tip or 1 mm tip) Pack 1 190-050 or 190-1007 Straight Forceps, 15 cm, (0.30 mm tip or 1 mm tip or 2 mm tip) Pack 1 120-030 or 120- 100 or 120-2008 Straight Forceps, 18 cm, (0.30 mm tip or 1 mm tip or 2 mm tip) Pack 1 130-030 or 130-100 or 130-2009 Straight Forceps, 20 cm, (0.30 mm tip or 1 mm tip or 2 mm tip) Pack 1 140-030 or 140- 100 or 140-20010 Straight Forceps, 22 cm, (0.30 mm tip or 1 mm tip or 2 mm tip) Pack 1 150-030 or 150-100 or 150- 200
6
7
8
9
10
Symbols: Products on this pageare Autoclavable and Latex Free
www
RE-USABLE BIPOLAR FORCEPS
11 Straight Forceps, angled, 15 cm, (0.30 mm tip or 1 mm tip, 2 mm tip) Pack 1 122-030 or 122-100 or 122-20012 Straight Forceps, angled, 18 cm (0.30 mm tip or 1 mm, 2 mm tip) Pack 1 132-030 or 132-100 or 132- 20013 Straight Forceps, angled, 20 cm (0.30 mm tip or 1 mm, 2 mm tip) Pack 1 142-030 or 142-100 or 142-20014 Straight Forceps, angled, 22 cm (0.30 mm tip or 1 mm, 2 mm tip) Pack 1 152-030 or 152-100 or 152-200
21 ELECTROSURGERY RE-USABLE BIPOLAR FORCEPS
+44 (0) 1453 756750
+44 (0) 1453 752626
www.prima-medical.com
11
12
13
14
Symbols: Products on this pageare Autoclavable and Latex Free
ELECTROSURGERY RE-USABLE BIPOLAR FORCEPS 22
15 Bayonet, 16.5 cm, (0.30 mm tip or 1 mm or 2 mm tip) Pack 1 160-030 or 160-100 or 160- 20016 Bayonet, 18 cm, (0.30 mm tip or 1 mm or 2 mm tip) Pack 1 170-030 or 170-100 or 160- 20017 Bayonet, 20 cm, (0.30 mm tip or 1 mm or 2 mm tip) Pack 1 180-030 or 180-100 or 180-20018 Straight Irrigation, 18 cm, (0.50 mm tip or 1 mm tip or 2 mm tip) Pack 1 120-050 IR or 120-100 IR or 120-200 IR19 Bayonet Irrigation, 18 cm, (0.50 mm tip or1 mm tip or 2 mm tip) Pack 1 160-050 IR or 160-100 IR or 160-200 IR
15
16
17
18
19
23 ELECTROSURGERY RE-USABLE FOOTSWITCHES
Symbols: Products on this pageare Autoclavable and Latex Free
UNTERMINATED FOOTSWITCHES
(WITHOUT CONNECTORS)
ELECTROSURGERY RE-USABLE FOOTSWITCHES 24
www
FS209(Eschmann800 Series)
FS720(Erbe)
FS501(Erbe)
FS041(Bard/ Davol)
FS206(Valleylab)
FS250(Conmed/ Aspen)
FS217(Eschmann800 Series)
FS307(Eschmann800 Series)
FS109(Eschmann 300 & 400 Series)
FS117(Eschmann 300 & 400 Series)
FS718(Eschmann 300 & 400 Series)
FS719(Eschmann 300 & 400 Series)
FS207(Eschmann 300 & 400 Series)
FS555(Birtcher)
+44 (0) 1453 752626
+44 (0) 1453 756750
www.prima-medical.com
Yellow (Cut) Blue (Coag) Black White TwinGENERATORCONNECTOR
FOOTSWITCH
A
PNEUMATICALLY OPERATED (BELOW)
A Pneumatically operated footswitch for use withEschmann bipolar generators FS2000
Yellow (Cut)Single footswitch
FS355C
Blue (Coag)Single footswitch
FS355D
BlackSingle footswitch
FS355E
WhiteSingle footswitch
FS176
Twin footswitchFS355F
STANDARD CABLES ARE ALL 5 METRES LONG.
25 STANDARD CRUSH RESISTANT FIBRE OPTIC CABLES
Symbols: Products on this pageare Autoclavable and Latex Free
STANDARD CRUSH RESISTANT FIBRE OPTIC CABLES STANDARD CRUSH RESISTANT FIBRE OPTIC CABLES STANDARD CRUSH RESISTANT 26
FO205-FPentax
FP FQ FR FAFAF
EP EQ ER EA
CP CQ CR CA
BP BQ BR BA
AP AQ AR AA
INSTRUMENTCONNECTOR
LIGHT SOURCECONNECTOR
FIBRE OPTIC CABLE
Available cable length 1.8 m Add 18 to code2.3 m Add 23 to code3.0 m Add 30 to code
Available Fibre-optic bundle diameter 3.5 mm Add 35 to code4.9 mm Add 49 to code
GENERATING YOUR FIBRE OPTIC ORDER CODE
The codes listed left are the fi rst part of your product code. To generate the second part, you need to know the length and diameter of the cable you require (see above).
For example; Fibre-Optic cable with C end + P end + 2.3 m cable + 3.5 mm diameter = CP2335
FO401-PBS / ACMI Female
FO402-QWolf / Dyonics
FO403-RStorz / Olympus
FO404-ABS / ACMI Male
FO201-AACMI British StandardACMI British Standard
FO202-BWolf / Dyonics
FO203-CStorz
FO204-E Olympus
P Q R A
A
B
C
E
F
NOT FOR USE WITH XENON LIGHT SOURCESWITHOUT HEAT FILTERS
27 RE-USABLE COLOURED COLOURED COLOURED COLOURED COLOURED COLOURED COLOURED COLOURED FIBRE OPTIC CABLES
Symbols: Products on this pageare Autoclavable and Latex Free
RE-USABLE HI-FLEX COLOURED FIBRE OPTIC CABLES 28
FPX/B /G /R /Y /GY
FQX/B /G /R /Y /GY
FRX/B /G /R /Y /GY
FAFAF X/B /G /R /Y /GY
EPX/B /G /R /Y /GY
EQX/B /G /R /Y /GY
ERX/B /G /R /Y /GY
EAX/B /G /R /Y /GY
CPX/B /G /R /Y /GY
CQX/B /G /R /Y /GY
CRX/B /G /R /Y /GY
CAX/B /G /R /Y /GY
BPX/B /G /R /Y /GY
BQX/B /G /R /Y /GY
BRX/B /G /R /Y /GY
BAX/B /G /R /Y /GY
APX/B /G /R /Y /GY
AQX/B /G /R /Y /GY
ARX/B /G /R /Y /GY
AAX/B /G /R /Y /GY
INSTRUMENTCONNECTOR
LIGHT SOURCECONNECTOR
FO401-PBS / ACMI Female
FO402-QWolf / Dyonics
FO403-RStorz / Olympus
FO404-ABS / ACMI Male
FO201-AACMI ACMI British Standard
FO202-BWolf / Dyonics
FO203-CStorz
FO204-E Olympus
P Q R A
A
B
C
E
F
SUITABLE FOR USE WITH XENON LIGHT SOURCES
• For use with Xenon light source• high-fl ex armoured cables• choice of colours - identify your department!
FIBRE OPTIC CABLE
Available cable length 1.8 m Add 18 to code2.3 m Add 23 to code3.0 m Add 30 to code
Available Fibre-optic bundle diameter 3.5 mm Add 35 to code4.9 mm Add 49 to code
GENERATING YOUR FIBRE OPTIC ORDER CODEThe codes listed left are the fi rst part of your product code. To generate the second part, you need to know the length and diameter of the cable you require (see above). For colour choice add /B for Blue, /G/G/ for Green, /R for Red, /Y/Y/ for Yellow and /GY for GreyFor example; Fibre-Optic cable with C end + P end + 2.3 m cable + 3.5 mm diameter in = CP2335/R
CRUSH RESISTANT
ARMOURED CABLES
www
GENERATORCONNECTOR
Symbols: Products on this pageare Autoclavable and Latex Free
29 ELECTROSURGERY RE-USABLE DISPERSIVE CABLES
+44 (0) 1453 756750
+44 (0) 1453 752626
www.prima-medical.com
3 m
5m DE1545
DE1543
Valleylab, Erbe to 2.5 cm split-pad
DE1535
DE1533
Valleylab, SSE2, K, L, SSE3
DE1515
DE1513
GU, Eschmann 300 Series
DE1505
DE1503
6.25 mm connectorfor Bard, Eschmann 400
Series and Martin
Fits standard 25 mm wide dispersive plate
DISPERSIVE PLATECONNECTOR
Fits standard 25 mm wide dispersive plate
• Autoclavable• double insulated• wipe clean round section surface
www
Prima Medical Ltd. Terms & Conditions
All orders for the sale of goods are accepted by Prima Medical Ltd on these terms & conditions, which supersede any previosly published terms in a catalogue or elsewhere.
Offers & AcceptanceNo obligation shall arise as a result of a catalogue entry, quotation or any other offer, until the company accepts the order from a customer, company or other organisation seeking to make a purchase.
OrdersWhere possible, please ensure to place an order by mail or fax. However, when ordering by phone, ensure you have all relevant details to hand in order to speed your order through the process. All orders will only be processed when made with full payment, except for organisations and companies with account facilities with Prima Medical Ltd. All orders will only be processed for such account holders on provision of an Offi cial Purchase Order, which has been duly signed.
situation will be made. Claims for products shipped faulty or damaged must be made within 3 working days.
WarrantyPrima Medical Ltd will, at its discretion, repair, replace or refund a product that develops a fault/s within the given guarantee period that are a result of faulty workmanship or design. In the unfortunate event of a fault arising, you should return the product to your nearest distributor for examination by the distributors’ staff, or telephone the Order Line for advice. The warranty is void if any modifi cation or attempted repair has been made to a product, or the product as been subjected to accidental damage. This warranty excludes any liability for consequential loss arising from defective products.
LawAny business transacted by Prima Medical Ltd is governed solely by English Law and none of the conditions stated affect your statutory rights.
SL002 12.06 © Prima Medical Ltd 2006
retain them for our representative or courier. None of these conditions affect your statutory rights.
Back OrdersWe reserve the right to ship part orders, or to hold orders until all items are available as required. We shall only levy one delivery charge. We reserve the right to cancel any part of an outstanding order should securing supply become untenable.
Cancelling an OrderOrders can only be cancelled by prior agreement of Prima Medical Ltd. Where possible, and shipment from vendor or ourselves has not been made, we shall agree. Should a customer default on an order outside these terms we reserve the right to deduct the relevant costs of shipment and administration incurred by Prima Medical Ltd.
ReturnsNo goods can be returned to the company without its express consent. In the event of faulty or damaged goods being received by the purchaser, please contact and advise us of the problem, whereupon arrangements to rectify the
PricesPrima Medical Ltd reserves the right to alter prices at any time without prior notice. Prices charged will be as quoted when the order is received and accepted. When an order is received and the price has altered upwards, you will be contacted and invited to consider the new price, prior to processing your order.Where the price is altered downwards, we will process the sale at the new price.
Satisfaction GuaranteeIt is our policy that if you are not totally satisfi ed with a product within 7 days of receipt, you may return the goods in their original packaging, including literature, in ‘as new’ condition. We only ask that the goods must be unused and in their original packaging. We reserve the right to apply a restocking charge of up to 25%.The guarantee does not apply to the sterile products, ‘specials’ or cut lengths of cable. No goods may be returned without a returns authorisation number, issued by our customer services helpline (+44 (0) 1453 752 626). Claims for goods damaged in transit must be made within 3 days of delivery. In the case of damaged items, always
+44 (0) 1453 756750
+44 (0) 1453 752626
www.prima-medical.com