generic unit installation manual - sk staycationbc+an2-instb.pdf · generic unit installation...

49
Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and Agriculture through Precision Measurement

Upload: doannga

Post on 15-May-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

Generic Unit

Installation Manual

Spray Height Controller

Improving the competitiveness of Industry and

Agriculture through Precision Measurement

Page 2: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

Printed in Canada Copyright 2008 by NORAC Systems International Inc. Reorder P/N: UC4+BC+AN2-INST Rev B (Generic Unit)

NOTICE NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.

Page 3: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

TABLE OF CONTENTS

1 INTRODUCTION.................................................................................................................................. 1

2 GENERAL SYSTEM DESCRIPTION ......................... ......................................................................... 2

3 PARTS LISTS ........................................ .............................................................................................. 3

4 INSTALLATION PROCEDURE ............................. .............................................................................. 5

4.1 DETERMINING THE STYLE OF INSTALLATION .................................................................................... 5 4.1.1 Electrically Teed Installation.................................................................................................... 5 4.1.2 Hydraulically Teed Installation................................................................................................. 8

4.2 EXISTING SYSTEM CHECK ............................................................................................................. 11 4.3 BOOM SPEED TEST...................................................................................................................... 11 4.4 WING SENSOR INSTALLATION ....................................................................................................... 13 4.5 MAIN LIFT SENSOR INSTALLATION ................................................................................................ 16 4.6 ROLL SENSOR INSTALLATION ....................................................................................................... 17

4.6.1 Trapeze Style Roll Sensor Installation .................................................................................. 18 4.6.2 Center Pivot Style boom Roll Sensor Installation.................................................................. 21 4.6.3 Inverted Roll Sensor Mounting .............................................................................................. 23 4.6.4 Temperature probe................................................................................................................ 23

4.7 HYDRAULIC INSTALLATION ........................................................................................................... 24 4.7.1 Valve Assembly ..................................................................................................................... 24 4.7.2 Valve Mounting...................................................................................................................... 25 4.7.3 Hydraulic Plumbing – Electrically Teed................................................................................. 26 4.7.4 Hydraulic Plumbing – Hydraulically Teed.............................................................................. 26

4.8 ELECTRICAL INSTALLATION .......................................................................................................... 27 4.8.1 Cable Installation: Electrically teed Installation ..................................................................... 30 4.8.2 Cable Installation: Hydraulically Teed Installation................................................................. 34

4.9 COMPLETING THE INSTALLATION .................................................................................................. 35

5 ELECTRICAL REFERENCE – CABLE DRAWINGS.............. .......................................................... 36

5.1 ITEM C2: 44668 – SENSOR BRANCH CABLE ................................................................................. 36 5.2 ITEM C02B: 44664 – CABLE UC4 CAN NODE DUAL .................................................................... 37 5.3 ITEM C3: 44656 – VALVE CABLE (VARIABLE RATE)...................................................................... 37 5.4 ITEM C10: 44658-39 – POWER CABLE GENERIC SELF – PROPELLED ............................................ 38 5.5 ITEM C11: 44651-03 – EXTENSION CABLE VALVE GENERIC ......................................................... 39 5.6 ITEM C12A: 44658-35 - VALVE INTERFACE CABLE PIGTAIL .......................................................... 40 5.7 ITEM C12B: 44658-36 – WING/BYPASS INTERFACE CABLE .......................................................... 41 5.8 ITEM C13: 44658-37: VALVE INTERFACE CABLE MAIN LIFT ONLY ................................................. 42 5.9 ITEM C15: 44658-31 – HAND CONTROL INTERFACE CABLE .......................................................... 43

Page 4: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

1

1 INTRODUCTION

Congratulations on your purchase of the NORAC UC4+ Spray Height Controller. This system is manufactured with top quality components and is engineered using the latest technology to provide operating features and reliability unmatched for years to come.

When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.

Please take the time to read this manual completely before attempting to install the system. A thorough understanding of this manual will ensure that you receive the maximum benefit from the system.

YOUR INPUT CAN HELP MAKE US BETTER! If you find is sues or have suggestions regarding the parts list or the installation procedure, please don’t hesitate to contact us via the information given below:

Phone: 1-800-667-3921 Canada (Toll Free)

1-866-306-6722 United States (Toll Free)

0-800-404-8389 United Kingdom (Toll Free)

1-306-664-6711 all other regions

E-mail: [email protected]

Website: www.norac.ca

Page 5: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

2

2 GENERAL SYSTEM DESCRIPTION

Figure 1 depicts the general system layout of the UC4+ Spray Height Control system.

Figure 1 – System Components and General Location

NOTICE:

Every effort has been made to ensure the accuracy of the information contained in this manual. All parts supplied are selected specially to fit the sprayer to facilitate a complete installation. However, NORAC cannot guarantee all parts fit as intended due to the variations of the sprayer by the manufacturer. Please read this manual in its entirety before attempting installation.

ATTENTION:

When installing the UC4+ Spray Height Control system please be aware that at a point in the installation your sprayer booms will be inoperative until the installation is complete. Any installation procedure requiring boom movement will need to be done first. Once the hydraulics have been disconnected you must complete the electrical installation before the booms become operative.

Page 6: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

3

3 PARTS LISTS

The parts that come with your UC4+ Spray Height Control system are listed in Table 1. The item number on the left side of this table references each part.

Please ensure that all parts in your kit are present before proceeding with your installation.

Table 1 – Sprayer Boom Control System Parts (Rev A)

Item Part Number Name Quantity

B05 44706-01 KIT CABLE TIE BLACK 10 PCS 21 IN 150 PCS 7.5 IN 1

B10 44700-06 BRACKET VALVE MOUNTING STD 1

B11 44743 MOUNTING BRACKET MAIN LIFT SENSOR UC4 PLUS 1

B13 44728 MOUNTING BRACKET COMPLETE UC4 BREAKAWAY EXTENDED 2

C02 44668 CABLE UC3 SENSOR BRANCH 1 AMP RECEPT 3 AMP PLUG BC 1

C02B 44664 CABLE UC4 CAN NODE DUAL 1

C03 44656D CABLE VALVE VARIABLE RATE DT 1

C10 44650-39 CABLE POWER GENERIC SELF-PROPELLED 1

C11 44651-03 CABLE EXTENSION VALVE GENERIC 1

C12A 44658-35 INTERFACE CABLE UC4 C12A GENERIC GND2 1

C12B 44658-36 INTERFACE CABLE WINGS UC4 C12B GENERIC GND2 1

C13 44658-37 INTERFACE CABLE MAIN UC4 C13 GENERIC GND2 1

C15 44658-31 CABLE INTERFACE UC4 BC C15 HAND CONTROL PIGTAIL 1

E01 4461BC+ UC4 PLUS BOOM CONTROL PANEL 1

E02 44631 UC4 ULTRASOUND SENSOR 3

E03 44641 UC4 PLUS ROLL SENSOR W TEMPERATURE PROBE 1

E04 44642 UC4 PLUS ROLL SENSOR 1

H01 44865-01 HYDRAULICS FITTING KIT - AN2 1

M01A 446BC+MAN6-1 MANUAL UC4+ BOOM CONTROL 2008 OPERATORS SMALL BOOKLET 1

M01B 446BC+MAN6-2 MANUAL UC4+ BOOM CONTROL 2008 QUICK REFERENCE SMALL BOOKLET 1

M10 UC4+BC+AN2-INST MANUAL INSTALLATION UC4+ GENERIC KIT 1

V01 44933D VALVE BLOCK ASSEM UC5-BC 2-STATION CC/LS VARIABLE RATE DT CONNECTORS 1

Page 7: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

4

Table 2 - 44865-01 (Rev A) - Hydraulics Fittings Kit Details

Item Part Number Name Quantity Picture

F07 103312 MALE ADAPTER - 6MB-6MJ 6

F08 44928 ORIFICE INSERT .047 IN ONE WAY 4

F09 104369 PLUG - 6MBP 2

6 M B - 6 M OR X 90SIZE IN 1/16TH'S

GENDER: MALE OR FEMALE

90° ANGLESWIVELTYPEGENDERSIZE

TYPE:B - ORBJ - JICOR - FLAT FACEP - PIPE

Fitting Name Example:

Page 8: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

5

4 INSTALLATION PROCEDURE

4.1 DETERMINING THE STYLE OF INSTALLATION

In general, there are two styles of installation that can be done with the NORAC UC4+ Spray Height Control system System: Electrically Teed Installation and Hydraulically Teed Installation.

4.1.1 Electrically Teed Installation Electrically Teed Installation is the preferred style of installation. However, this style can be done only if the sprayer valve block has individual electrical wiring to control each boom function (e.g. left up, left down, right up, right down, main up, and main down).

Figure 2 – Electrical Wiring Applicable

for Electrically Teed Installation

Figure 3 and Figure 4 show the Electrically Teed installation in its general installation configuration.

Page 9: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

6

Figure 3 – UC4+ BC Components: Electrically Teed Installation

If your valve connectors or cables appear different than shown, refer to Appendix A for more details.

Page 10: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

7

Figure 4 – Hydraulic Components: Electrically Teed Installation

Page 11: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

8

4.1.2 Hydraulically Teed Installation Hydraulically Teed Installation must be done if the sprayer valve block does NOT have individual electrical wiring to control each boom function. For example, your sprayer may have signal lines to select a boom (left, right and main) and separate electrical signals for the direction (up and down).

Figure 5 – Typical Electrical Wiring for which Hydraulically Teed Installation is

Required

For Hydraulically Teed Installation, MANUAL mode of the UC4+ Control System does not operate the same as with Electrically Teed Installation. Electrically

Teed Installation will allow the operator to trigger individual boom movements into MANUAL mode while maintaining AUTO mode for the other boom movements (e.g. left boom can be in MANUAL mode while right boom is still in AUTO mode). Hydraulically Teed Installation does not support this function. If the operator triggers any boom movement, the whole NORAC system will convert to MANUAL mode.

Hydraulically Teed Installation may also be done if the operator wants the existing sprayer valves, instead of the NORAC valves, to operate the booms when the NORAC system is in MANUAL mode.

Figure 6 and Figure 7 show the Hydraulically Teed Installation in its general installation configuration.

Page 12: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

9

Figure 6 – UC4+ BC Components: Hydraulically Teed Installation

If your valve connectors or cables appear differently than shown, appear to Appendix A for more details.

Page 13: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

10

Figure 7 – Hydraulic Components: Hydraulically Teed Installation

Page 14: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

11

4.2 EXISTING SYSTEM CHECK

It is necessary to check the existing system’s functionality before installing the UC4+ Spray Height Control system.

1. Drive your sprayer onto a flat piece of land, with unobstructed boom movement (e.g. no power lines).

2. Test that all boom functions operate correctly. As you test each function check it off in Table 3.

It is necessary to test the boom functions in all directions

Table 3 – Hydraulic System Function Check Sheet

BOOMFOLD

INFOLD OUT UP DOWN

LEFTMAINRIGHTROLL* N/A N/A

* Some sprayers may not have this function.

4.3 BOOM SPEED TEST

IMPORTANT :

Raise/lower all boom sections several times to warm up the hydraulic system. Grease all moving parts for consistent results.

1. Lower each boom and main section as close to the ground as possible.

2. Set your sprayer at field working RPM on the throttle and mark this value in Table 4.

You will need a stopwatch or a watch that displays “seconds” for the next step.

3. Raise the LEFT boom from its extreme LOW position to the very TOP of its travel. Record the time this takes in Table 4, “Trial #1” for “Left UP”.

4. Lower the LEFT boom from its extreme HIGH position to the BOTTOM of its travel. Record this time in Table 4, Trial #1, for “Left DOWN”.

Be careful when lowering the booms so they don’t hit the ground.

5. Similarly, record two more time trials (Trial #2 & #3) for the LEFT boom and record in Table 4

6. Repeat Steps 1 through 5 for the RIGHT, MAIN and ROLL functions.

Your sprayer may not have a roll feature.

7. Average the three trials recorded for each boom movement and record this calculation in the “Average Time” slot in Table 4.

8. These “Average Times” now represent how quickly your system can react to manual control. In Section 1.1, this procedure is repeated with the UC4+ Spray Height Control system installed for comparison and troubleshooting purposes.

Page 15: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

12

Table 4 – Boom Test Record (WITHOUT UC4+ Spray Height Control system)

Working RPM:

Boom Trial #1

[Sec]

Trial #2

[Sec]

Trial #3

[Sec]

Avg Time

[Sec]

Left UP

Left DOWN

Right UP

Right Down

Main UP

Main DOWN

Roll CW

Roll CCW

Table 5 – Boom Test Record (WITH UC4+ Spray Height Control system)

Working RPM:

Boom Trial #1

[Sec]

Trial #2

[Sec]

Trial #3

[Sec]

Avg Time

[Sec]

Left UP

Left DOWN

Right UP

Right Down

Main UP

Main DOWN

Roll CW

Roll CCW

Page 16: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

13

4.4 WING SENSOR INSTALLATION

1. Assemble the Breakaway Sensor Mounting Brackets (B11) as show in Figure 8 and Figure 9.

Figure 8 – Breakaway Sensor Bracket Exploded View

Figure 9 – Breakaway Sensor Mounting Bracket Assembly

To assemble the breakaway sensor bracket:

a) Assemble the bolt and nut into the collar.

b) Grease the bottom edge of the collar and the angled tube of the base.

c) Place the collar onto the angled tube of the mounting base.

d) Install the spring between the collar and the upper ring of the base.

e) Insert tube through assembly and tighten the collar

2. Mount the sensor bracket onto the boom.

If possible, mount the sensor brackets while the booms are in their folded position to ensure that they will not interfere with anything when the boom is folded for transport.

3. The sensor mounting brackets can be installed with the mounting base behind (Figure 12) or in front of the tube (Figure 10).

It is advised to avoid mounting the sensor bracket to a breakaway portion of the boom because a breakaway action can cause the UC4+ Spray Height Control system to force a boom close to the ground.

Please refer to the UC4+ Spray Height Control system warranty at the end of the UC4+ Sprayer Boom Control Operator’s Manual (M01) for implications.

4. Mount the NORAC UC4+ ultrasonic sensor (E02) into the sensor brackets. The sensors should be oriented forward (ahead) of the boom (see Figure 10 and Figure 12).

When installing the UC4+ sensors (E02), start with the smallest serial number on the left hand side proceeding to the largest serial number on the right hand side (Figure 13).

Page 17: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

14

5. Sensor cables should run through the mounting bracket tube and then behind the member the bracket is mounted onto. Cable-tie the connector in place. The cable must not be allowed to hang below the boom (Figure 10).

Figure 10 – Another Acceptable Mounting

Avoid mounting sensors in locations where they may read from parts of the boom as shown in Figure 11.

Figure 11 – Poor Mounting (Sensor reading off boom)

General mounting rules for UC4+ ultrasonic wing sensors:

a) In its lowest position, the sensor mouth must be 9 inches or more from the ground.

b) The bottom of the sensor must be at least 9 inches in front of the spray nozzles.

c) The bottom of the sensor must be at least 9 inches above the spray nozzles.

d) Ensure that there are no obstructions within a 12-inch diameter circle projected directly below the center of the sensor.

e) The sensor should be approximately vertical at normal operating heights.

Figure 12 – Sensor Mounting Guidelines

A B

B

D

C

Ultrasonic

Acoustic Cone

Page 18: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

15

Figure 13 – Sensor Serial Number Installation Location

3 SENSOR SYSTEM

5 SENSOR SYSTEM

Page 19: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

16

4.5 MAIN LIFT SENSOR INSTALLATION

1. Assemble the main lift sensor bracket (B11) as shown in Figure 14.

Figure 14 – Main Lift Sensor Bracket

2. The bracket can then be mounted to the lowest frame member on the center section of the sprayer. The bracket should be mounted so the sensor mounting collar is in approximately the center of the sprayer and ahead of the boom (Figure 15 and Figure 16).

The sensor mounting collar must not be behind the sprayer’s wheel.

The General Mounting Rules for UC4+ Ultrasonic Sensors, from the previous section, must be followed.

Figure 15 – Main Lift Sensor Bracket Mounting Position

3. Mount the sensor onto the sensor mounting collar (Figure 15).

Figure 16 – Main Lift Sensor Mounted in the Correct Location

Bracket Tube

Sensor Mounting Tab

Sensor Mounting Collar

Bracket Base

Page 20: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

17

4.6 ROLL SENSOR INSTALLATION

Mount the roll sensors to the included roll sensor brackets using the machine screws and nylon lock nuts, as illustrated in Figure 17.

The roll sensors must be mounted tightly to the brackets.

If your sprayer is a trapeze style pivoting boom (the boom hangs from two link arms) then follow Section 0to install the roll sensors.

If your sprayer is a center pin pivoting boom (the boom pivots on a pin in the center of the boom) then follow Section 4.6.1.1 on page 19to install the roll sensors.

Sometimes it best to mount the roll sensors in an inverted orientation (upside down). For this type of mounting refer to Section 4.6.3 on page 23.

Figure 17 - Mounting the roll sensor to the roll sensor mounting bracket

Page 21: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

18

4.6.1 Trapeze Style Roll Sensor Installation

This section is only for trapeze style booms (booms that hang from link arms. If your sprayer has a center pivot boom proceed to Section 4.6.2.

When mounting the roll sensors, use the following guidelines and refer to Figure 18.

a) The smaller the distance between A and B in Figure 17, the better the performance will be.

b) Ensure the roll sensors are sitting relatively level when the sprayer chassis and booms are level.

c) Both roll sensors must be mounted with the circular AMP connector facing towards the Right-Hand Wing (when looking from the rear of the sprayer).

Figure 18 - General Roll Sensor mounting location on a Trapeze style boom

Connectors towards Right-hand Wing �

Page 22: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

19

4.6.1.1 Boom Frame Roll Sensor Mounting

1. Use the supplied hardware to mount the boom frame roll sensor (E04) as shown in Figure 19.

When mounting the boom frame roll sensor follow these guidelines:

a) To prevent bending the bracket, ensure bolts are placed as close together as possible (minimize C in Figure 19).

b) Be sure to use the roll sensor without the temperature probe (E04).

c) When the boom is centered (not rolled over) the roll sensor should be level with respect to the sprayer chassis.

d) It is best to mount the roll sensor to the left hand trapeze link (when looking from the rear of the sprayer).

e) The roll sensor AMP (circular) connector MUST exit towards the right had wing (when looking from the rear of the sprayer).

Figure 19 - Boom frame roll sensor mounted to a trapeze link

2. Cable-tie the sensor connector to the frame with enough slack to allow the link to rotate.

Make sure the bracket does not collide with any parts of the sprayer when the boom rotates. Also ensure there is enough slack to allow the roll sensor to rotate.

Page 23: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

20

4.6.1.2 Chassis Roll Sensor Mounting

1. It is often best to cable tie the chassis roll sensor in place. When mounting the chassis roll sensor follow the guidelines and refer to Figure 20.

The chassis roll sensor must be mounted on a portion of the sprayer that does not pivot and is as close to the boom frame roll sensor as possible (Figure 18).

a) Make sure you are using the roll sensor with the temperature probe (E03).

b) Ensure the roll sensor is level with respect to the chassis.

c) The AMP (circular) connector MUST exit towards the right hand wing.

d) Make sure the temperature probe is able to reach the side of the valve block.

Figure 20 - Chassis roll sensor mounting

2. Refer to Section 4.6.4 on page 23 for mounting the temperature probe.

Page 24: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

21

4.6.2 Center Pivot Style boom Roll Sensor Installation

This section is only for center pivot booms (booms that pivot on a pin). If your sprayer is a trapeze style boom use Section 4.6.1.

When mounting the roll sensors use the following guidelines and refer to Figure 21.

a) The smaller the distance between A and B in Figure 21, the better the performance will be.

Distance A can not be more than 12”.

b) The roll sensors must not be mounted below the pivot point.

c) Ensure the roll sensors are sitting relatively level when the sprayer chassis and boom are level.

d) Both roll sensors must be mounted with the circular AMP connector facing towards the Right-Hand Wing (when looking from the rear of the sprayer).

Figure 21 - Mounting guildines for center pivot sprayers

Connectors towards Right-hand Wing �

Page 25: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

22

Figure 22 - Roll sensor mounting with respect to sprayer orientation

4.6.2.1 Boom Roll Sensor Mounting

The boom roll sensor (E04) must be mounted to the rotating part of the boom. Follow these guidelines and refer to Figure 21 and Figure 23 to mount the sensor.

a) Make sure you are using the roll sensor that does NOT have a temperature probe (only one cable) (E04).

b) The boom roll sensor must be mounted to the rotating part of the boom suspension.

c) Use cable-ties to secure the bracket to a square edge feature (square tube).

d) Ensure the AMP (circular) connector exits towards the Right Hand Wing (when looking from the rear of the sprayer).

e) Securely cable-tie the connector to the frame.

4.6.2.2 Chassis Roll Sensor Mounting

The chassis roll sensor must be mounted to a non-rotating part of the boom.

a) Make sure you are mounting the roll sensor that does have a temperature probe (2 cables) (E03).

b) Mount the chassis roll sensor (E03) to a non-rotating part of the boom.

c) Cable-tie the bracket to a square edge feature (square tube).

d) The AMP (circular) connector MUST exit towards the Right Hand Wing (when looking from the rear).

e) Securely cable-tie the connector to the frame.

* The boom frame roll sensor does not have a temperature probe

Page 26: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

23

Figure 23 - Boom and chassis roll sensors correclty mounted

4.6.3 Inverted Roll Sensor Mounting If desired, the Roll sensor may be mounted inverted, so long as the connector exits towards the right-hand boom. Inverted

mounting may be used to optimize the mounting criteria.

Figure 24 - Inverted roll sensor mounting may be applicable in order for optimal performance

4.6.4 Temperature probe Fasten the temperature probe (E03) to the UC4 valve block using the included 3/8x1/2” bolt as illustrated in Figure 25.

Figure 25 - UC4+ Valve block with temperature probe installed

E04

E03

Page 27: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

24

4.7 HYDRAULIC INSTALLATION

WARNING!

The hydraulic system creates very high pressure. Before disconnecting any hydraulic lines ensure all pressure has been bled from the system. When changing the boom hydraulic hoses leave the booms in TRANSPORT POSITION.

NORAC provides proportional hydraulic valves for sprayer boom applications. For the generic installation kit, the customer must supply all hoses and fittings required. The fittings (Item F07) on the NORAC valve block are #6 MB (male ORB) to #6 MJ (male JIC). You will need the mating female JIC fitting on your hoses. If an adapter is required, add it after the JIC portion of these fittings. For a typical hydraulic layout, refer to the installation instructions and Figure 4 and Figure 7.

IMPORTANT :

Component failure due to oil contamination is not covered under the UC4+ Spray Height Control system warranty. It is recommended that a qualified technician does the hydraulic installation.

4.7.1 Valve Assembly 1. On a clean surface remove all plastic

plugs from the NORAC hydraulic Valve (V01) (Figure 26).

2. Install the 6MB-6MJ fittings (F07) on the "P" and "T" ports and tighten to 18 ft-lbs.

Figure 26 – NORAC Valve Block

4. At this point the sprayer hydraulic system must be identified as being single acting or dual acting.

4.7.1.1 Dual Acting Assembly

1. Install the orifices (F08) into the "B" ports with the notch facing outward as shown in Figure 27.

2. Install the orifices (F08) into the "A" ports with the notch facing inward as shown in Figure 27.

3. Install the 6MB-4MJ fittings (F07) into the "A" and "B" ports and tighten to 18 ft-lbs.

Figure 27 – Dual Acting Valve Block

Page 28: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

25

4.7.1.2 Single Acting Assembly

1. Install the orifices (F08) into the “B” ports with the notch facing outward as shown in Figure 28.

2. Install the 6MB-6MJ fittings (F07) into the “B” ports and tighten to 18 ft-lbs.

3. Install the 6MBP plugs (F09) into the “A” ports and tighten to 18 ft-lbs.

Figure 28 – Single Acting Valve Block

4.7.2 Valve Mounting

1. Mount the NORAC valve (V01) on the sprayer using the valve mounting bracket (B10).

2. Thread a nut onto the short threads of each of the threaded studs.

3. As shown in Figure 29, screw the short side of the threaded rods into the bottom of the valve block and tighten the hex nuts tight to the valve block.

4. Place the valve block onto a frame member, with the studs extending to the other side of the member.

5. Slide the flat bar from the bracket over the studs and install a spring washer and

nut onto each of the studs to hold the plate in place.

6. Tighten the two nuts so the valve block is held on tight and cannot move.

7. Cut excess off of the rods, if necessary.

If you wish to use bolts, the bolts should thread into the valve block at least 3/8". The valve mounting holes are drilled and tapped 3/8 NC-1" deep. The rule of thumb for bolt length is 1-1/2" longer than the tube size.

You must ensure no hydraulic components will interfere with any sprayer parts or be pulled tight at any time.

Figure 29 – Valve Mounting Location

Page 29: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

26

4.7.3 Hydraulic Plumbing – Electrically Teed

WARNING!

From this point in the installation the booms will be inoperative until the electronics are fully installed.

1. After the NORAC valves are mounted, the hydraulic hoses and fittings can be plumbed. The plumbing for the hydraulic circuit is shown schematically in Figure 4.

2. Tee in pressure (“P”) and tank (“T”) lines to the NORAC valve block.

3. The existing hoses that run to the boom tilt cylinders should be disconnected from the sprayer valve block and reconnected to the NORAC valve block.

a) The raise lines from the boom tilt cylinders must be connected to the “B” ports of the NORAC valve block. The ports on the sprayer block must then be plugged/capped.

b) If the sprayer is Dual Acting, the “A” ports of the NORAC block must be connected to the “lower” lines of the cylinders. The ports on the sprayer block must then be plugged/capped.

c) If the sprayer is Single Acting, the “A” ports on the NORAC block are plugged. The lower lines of the cylinders can remain attached to the sprayer valve block.

4.7.4 Hydraulic Plumbing – Hydraulically Teed

1. Follow Figure 7 to plumb the hydraulic components.

2. Tee in the pressure (“P”) and tank (“T”) lines to the NORAC valve block.

3. The existing hoses that run to the boom tilt cylinders should be disconnected from the sprayer valve block and teed into the NORAC valve block.

4. The “raise” lines from the boom tilt cylinders must be connected to the “B” ports of the NORAC valve block.

a) If the sprayer is Dual Acting, the “A” ports of the NORAC block must be connected to the “lower” lines of the cylinders.

b) If the sprayer is Single Acting, the “A” ports on the NORAC block are plugged. The “lower” lines can remain attached to the sprayer valve block.

Page 30: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

27

ROP 4.8 ELECTRICAL INSTALLATION

While installing the electrical parts of the system you may need to refer to Section 5.

1. Install the UC4+ Control Panel (E01) in the cab of the sprayer. Mount the panel where it will be clearly visible and within easy reach of the operator.

A good spot to mount the UC4+ control panel is on the right hand side of the cab to the Roll Over Protection Bar. Four pilot holes for the screws provided need to be drilled to facilitate the control panel mounting.

Another option is to purchase an adapter for the flexible panel mount that has a 3/8" NC threaded stud on the end to bolt through an existing mount. You can find these at your local outdoor store as a RAM mount part number RAM-B-236. (See http://www.ram-mount.com/)

Figure 30 – Control Panel Mounting

ROP

Page 31: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

28

Figure 31 – Cable Configurations: C10 and C11

2. Connect the UC4+ power cable (C10) to the UC4+ Control Panel in the sprayer cab. Ensure that both plugs (P16A and P4) are connected to the panel (Figure 31).

Ensure the UC4+ control panel’s power is OFF for the remaining installation (Bottom of switch pressed IN).

3. Connect the 3-pin AMP connector (P3) of C10 to an auxiliary power connection inside the cab. If an appropriate connector can not be found, it may be necessary to cut off the connector(s) and splice into the existing wiring.

For a clean connection to the 12 V power supply, NORAC provides optional power interface cables.

4. For Electrically Teed Installation, please read Section 4.8.1.

5. Route the receptacle end (R16) of C10 to the exterior of the cab.

6. Connect the 16-pin AMP plug (P16) of the valve extension cable (C11) to R16 of C10 (Figure 31).

For a pull type sprayer, connect at the hitch. This connection will provide your hitch disconnect.

Page 32: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

29

Figure 32 – Cable Configurations: Electrically Teed Installation

Figure 33 – Cable Configurations: Hydraulically Teed Installation

7. Route C11 to the rear of the sprayer near the vicinity of the sprayer valve block.

8. For Electrically Teed Installation, read Section 4.8.1.1. For Hydraulically Teed Installation, read Section 4.8.2.

9. Connect the 6-pin tower on the valve cable (C3) to the mating 6-pin shroud (S6A) on C11 (Figure 32 / Figure 33).

10. Install the square DIN connectors from C3 onto the NORAC valve block (Figure 34). The connectors are marked RIGHT UP, LEFT UP, RIGHT PORT and LEFT PORT. Cables labeled with PORT go on the side as the hydraulic hoses. Fasten with the included rubber seals and screws.

Page 33: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

30

Figure 34 – Valve Cable Connections

11. Connect the CAN Node cable (C02B) to the 4-pin AMP plug on C11 (Figure 35).

12. Route the CAN Node cable (C02B) to the roll sensors. Follow existing cables and/or hydraulic lines.

13. Connect the sensor branch cable (C02) to the 4-pin AMP plug on C02B (Figure 35).

14. Route the sensor branch cable (C02) to the wing and main sensors. Follow existing cables and/or hydraulic lines along the boom.

15. Cable-tie the installed cables every 12 inches.

IMPORTANT :

Provide enough slack in all cables to account for the movement of the main section, parallel lift, and FOLDING boom movement.

Figure 35 – Cable Configurations: C11, C02B and C02

4.8.1 Cable Installation: Electrically teed Installation

For Electrically Teed Installation, there are two different methods of cable installation to tee in to the sprayer’s control system. The first is teeing the NORAC system in to the sprayer’s wiring inside the cab (Section 4.8.1.1). The second is teeing the NORAC system in to the sprayer’s wiring at the valve block (Section 4.8.1.2). Choose one of the two methods, whichever is suitable for your sprayer.

4.8.1.1 Cable Connections Inside Cab

Figure 36 – Cable Configurations: C10

and C15

Page 34: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

31

1. Connect the 16-pin AMP plug (P16B) of C10 to R16 of C15

2. String the cable jacket of the pigtail (N15) on C15 (Figure 36).

3. Splice the wires (N15) of C15 into the existing wiring to tee into appropriate functions of the sprayer’s control system. The wire colors and functions

are shown below. Some wires may not be used for this installation. Before connecting the wire of N15, check each sprayer wire you will be splicing to.

4. Disconnect the electrical connections of the left/right boom tilt functions: Left Up, Left Down, Right Up and Right Down, from the sprayer’s existing valves.

Table 6 – N15: Wire Colors and Functions

COLOR FUNCTION

Green / White Main Up

Blue / White Main Down

Green Left Up

White Left Down

Green / Black Right Up

White / Black Right Down

Orange / Black Bypass

Blue Remote Manual

Blue / Black Remote Auto

Orange Motion Inhibit

Red / White Bias Down

Red / Black 12 V

Black Bias Up

Red N/A

Black / White N/A

Page 35: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

32

4.8.1.2 Cable Connections at Valve Block

Figure 37 – Cable Configurations: Electrically Teed Installation

Figure 38 – Schematic Diagram: Electrically Teed Installation

1. Connect the 6-pin Shroud (S6) on the generic interface cable (C12A) to the mating 6-pin Tower (T6A) on C11.

2. If there is an enable valve on the sprayer block, connect 3-pin Shroud (S3) of C12B to the mating 3-pin Tower (T3) on C11.

3. Route the free end(s) of C12A (and C12B) to the existing valve block.

4. Splice the loose wires of C12A (and N1C of C12B) into the existing wiring to tee in to appropriate functions of the sprayer’s control system. Each function is labeled on the wire of NORAC cables. Check each sprayer wire you will be

Page 36: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

33

splicing to before connecting the wires. Figure 38 is the typical schematic diagram of cable connections for Electrically Teed Installation.

N1A and N1B of C12B are not used for this installation.

5. Disconnect the electrical connections of the left/right boom tilt functions: Left Up, Left Down, Right Up and Right Down, from the sprayer’s existing valves.

Page 37: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

34

4.8.2 Cable Installation: Hydraulically Teed Instal lation

Figure 39 – Cable Configurations: Hydraulically Teed Installation

Figure 40 – Schematic Diagram: Hydraulically Teed Installation

1. Connect the 6-pin Shroud (S6) on the generic main interface cable (C13) to the mating 6-pin Tower (T6A) on C11.

2. Connect 3-pin Shroud (S3) of C12B to the mating 3-pin Tower (T3) on C11.

3. Route the free ends of C12A and C12B to the existing valve block.

4. Splice the loose wires of C12A and of C12B into the existing wiring to tee in to appropriate functions of the sprayer’s control system. Each function is labeled on the NORAC wires. Check each sprayer wire you will be splicing to before connecting the wires. Figure 40 is the typical schematic diagram of cable connections for Hydraulically Teed Installation.

Page 38: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

35

4.9 COMPLETING THE INSTALLATION

1. Start up your sprayer and test the sprayer’s functionality. The NORAC Control Panel does not need to be powered up for the original switches to function. Unfold the booms and raise/lower each boom and main section.

Again confirm that the cabling/hoses are agreeable to the entire range of motion.

2. If any functions do not work, review the hydraulic and electrical portions of this manual to check for proper installation. If you still have trouble, contact NORAC for assistance.

3. Turn on the power for the UC4+ Control Panel using the switch on the side of its chassis.

4. Repeat the Boom Speed Test as described in Section 4.3 Boom Speed Test with the NORAC UC4+ Spray Height Control system installed. Record the results for comparison in Table 5.

5. The procedure for the installation of the UC4+ Spray Height Control system is now complete. Begin the AUTOMATIC SYSTEM SETUP procedure as described in the UC4+ Sprayer Boom Control Operator’s Manual (M01A).

6. For a pull type sprayer, there should be very little play at the hitch clevis for optimal performance of the UC4+ Spray Height Control system. The addition of polymer washers can help tighten up this connection (Figure 41).

Figure 41 – Hitch Point

Page 39: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

36

5 ELECTRICAL REFERENCE – CABLE DRAWINGS

5.1 ITEM C2: 44668 – SENSOR BRANCH CABLE

Page 40: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

37

5.2 ITEM C02B: 44664 – CABLE UC4 CAN NODE DUAL

5.3 ITEM C3: 44656 – VALVE CABLE (VARIABLE RATE)

Page 41: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

38

5.4 ITEM C10: 44658-39 – POWER CABLE GENERIC SELF – PROPELLED

Page 42: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

39

5.5 ITEM C11: 44651-03 – EXTENSION CABLE VALVE GENERIC

Page 43: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

40

5.6 ITEM C12A: 44658-35 - VALVE INTERFACE CABLE PIGTAIL

Page 44: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

41

5.7 ITEM C12B: 44658-36 – WING/BYPASS INTERFACE CABLE

Page 45: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

42

5.8 ITEM C13: 44658-37: VALVE INTERFACE CABLE MAIN LIFT ONLY

Page 46: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

43

5.9 ITEM C15: 44658-31 – HAND CONTROL INTERFACE CABLE

Page 47: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

44

Page 48: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

45

6 APPENDIX A – VALVE CONNECTOR CHANGE

Starting in January 2009, NORAC is changing the connectors on the boom height control valve block. The new style valve block will have 2-pin Deutsch connectors on the coils. The previous models had Hirschman style connectors as shown in Error! Reference source not found. new style valve blocks and cabling look similar to Figure 42 and Figure 43. Your system may ship with either style valve block, both are functionally equivalent. The system will operate properly with either style of connector.

Figure 42: New two station valves and cabling with Deutsch connectors

Figure 43: New expansion block and cabling with Deutsch connectors

Displayed valve block 44933D replaces valve 44933S

Displayed valve block 44952D replaces valves 44952 and 44947

Page 49: Generic Unit Installation Manual - SK StaycationBC+AN2-INSTb.pdf · Generic Unit Installation Manual Spray Height Controller Improving the competitiveness of Industry and ... M10

46

Canada

NORAC Systems International Inc.

CALL TOLL FREE: 1-800-667-3921

(306)664-6711

SHIPPING ADDRESS:

3702 Kinnear Place

Saskatoon, SK

S7P 0A6

United States

Norac, Inc.

CALL TOLL FREE: 1-866-306-6722

(763)786-3080

SHIPPING ADDRESS:

1290 Osborne Rd NE, Suite F Fridley, MN 55432-2892

www.norac.ca