ggr manual

32
Manual: 02KM27EH-A Revision Date: 10/15/2004 Date: 02/17/04 The Titan Group www.titangroup.net Instrument Division TECHNICAL MANUAL 2 3/4” HIGH-TEMP SS PERF SCINT GR WITH ACTIVE/PASSIVE CCL & SHOCK TITAN PART NUMBERS: 8100-275BESF100-04-0C-A MANUFACTURING QUALITY PERFORATING GUNS AND HARDWARE SINCE 1966 DELIVERING QUALITY DOWNHOLE LOGGING INSTRUMENTS SINCE 1994

Upload: gustavojbn1885

Post on 07-Jul-2016

290 views

Category:

Documents


2 download

DESCRIPTION

ggr Manual

TRANSCRIPT

Page 1: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Date: 02/17/04

The Titan Group www.titangroup.net Instrument Division

TECHNICAL MANUAL

2 3/4” HIGH-TEMP SS PERF SCINT GR WITH ACTIVE/PASSIVE CCL & SHOCK

TITAN PART NUMBERS:

8100-275BESF100-04-0C-A

MANUFACTURING QUALITY PERFORATING GUNS AND HARDWARE SINCE 1966

DELIVERING QUALITY DOWNHOLE LOGGING INSTRUMENTS SINCE 1994

Page 2: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Date: 02/17/04

Titan Instrument Division II

MANUAL REVISION HISTORY

INSTRUMENT DIVISION DOCUMENTATION

TITAN SPECIALTIES, LTD. 2832 W. ALCOCK PAMPA, TX 79065

TITLE...............2 3/4” HIGH-TEMP SS PERF SCINT GR WITH ACTIVE/PASSIVE CCL & SHOCK RELEASE DATE.................................................................................................................... 02/17/04 REVISION DATE..................................................................................................... October 15, 2004 MANUAL NUMBER .......................................................................................................02KM27EH-A PART NUMBERS................................................................................... 8100-275BESF100-04-0C-A

NAME DATE SIGNATURE DEPARTMENT

Stephanie Lowe Documentation Chuck Smith Technical R&D

Demmie Mosley Engineering Mgmt

REVISION#...............................................................................................................REVISION DATE PURPOSE ............................................................................................................................................

Page 3: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Date: 02/17/04

Titan Instrument Division III

TABLE OF CONTENTS

GENERAL TERMS AND CONDITIONS...................................................................................................1

GENERAL COMMENTS ON GAMMA RAY LOGGING............................................................................4

BRIEF DESCRIPTION OF TOOL.............................................................................................................5

API CALIBRATION PIT.............................................................................................................................6

EXPLOSIVES FIELD SAFETY PROCEDURES.......................................................................................7

TOOL SPECIFICATIONS .........................................................................................................................8

TOOL SPACING.......................................................................................................................................9

COMPLETE TOOL ASSEMBLY.............................................................................................................10

GAMMA RAY & CCL TOOL ASSEMBLY ...............................................................................................11

TOP SUB ASSEMBLY............................................................................................................................12

COIL & MAGNET ASSEMBLY ...............................................................................................................13

CCL PC BOARD ASSEMBLY.................................................................................................................14

CCL SCHEMATIC...................................................................................................................................15

TANDEM ADAPTER ASSEMBLY ..........................................................................................................16

UPPER CONTACT HEADER ASSEMBLY.............................................................................................17

INTERNAL GAMMA RAY ASSEMBLY...................................................................................................18

CHASSIS ASSEMBLY............................................................................................................................19

TOP SCINTILLATION GAMMA RAY PC BOARD ASSEMBLY..............................................................20

BOTTOM SCINTILLATION GAMMA RAY PC BOARD ASSEMBLY......................................................21

SCINTILLATION GAMMA RAY PC BOARD SCHEMATIC ....................................................................22

SCHEMATIC (PAGE 2) ..........................................................................................................................23

BOTTOM SUB ASSEMBLY....................................................................................................................24

SHOCK ABSORBER ASSEMBLY..........................................................................................................25

BILL OF MATERIAL ...............................................................................................................................26

Page 4: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 1

GENERAL TERMS AND CONDITIONS

Effective Nov. 1, 2000

(See paragraph #3 for Hold Harmless Terms) The items to which these General Terms and Conditions refer are the items supplied or sold by Titan Specialties, Ltd. and/or Titan Completion Products, Ltd. (hereinafter referred to as “Titan”) to the purchaser thereof (hereinafter referred to as “Buyer”). These items are sold only under the following General Terms and Conditions:

1. Price. (a) All prices are expressed in United States dollars net FOB Pampa, Texas, and unless otherwise agreed in writing by Titan, are subject to change without notice and are at the prices in effect at the time of order placement. Quotations will be given on request for any item(s) offered by Titan. Quotations will remain in effect only for the period of validity specified therein or, if no such period is stated, for thirty (30) days from the date the quotation is given. (b) All prices are exclusive of costs of transportation and insurance and federal, state and local use, sales, property (advalorem) and similar taxes and license fees, import duties and the like. Buyer agrees, by purchase of an item, to pay such costs, taxes, fees and duties, and where appropriate, report the same. When applicable, such costs, taxes, fees, and duties will appear as separate items on Titan’s invoice. 2. Payment. (a) Payment for all items is net cash United States funds on delivery or shipment except that a Buyer with an established credit account currently approved by Titan shall pay net cash within thirty (30) days following invoice date. Partial shipments will be invoiced as made. Invoices are payable in Pampa, Gray County, Texas (b) Interest from due date until payment at the maximum rate allowable by law but in any event not more than eighteen percent (18%) per annum will be charged on invoices unpaid sixty (60) days after due date. If unpaid amounts are collected through legal proceedings or an attorney, Buyer shall pay reasonable attorneys’ fees and court costs. Titan shall never be entitled to receive, collect or apply as interest any amount in excess of the highest non-usurious rate of interest permitted by applicable law (the “Maximum Rate”). In the event that Titan ever receives, collects or applies as interest any amount in excess of the Maximum Rate, the amount which would be excessive interest shall be deemed to be a partial payment on the amount Buyer owes to Titan, or if Buyer does not owe any amount to Titan, any remaining excess shall be paid to the Buyer, and in such event, Titan shall not be subject to any penalties provided by any law for contracting for, charging, taking, reserving or receiving interest in excess of the Maximum Rate. 3. HOLD HARMLESS TERMS. (A) BUYER AGREES TO UNCONDITIONALLY PROTECT, DEFEND, INDEMNIFY AND HOLD TITAN, ITS EMPLOYEES, OFFICERS, AGENTS, AFFILIATES AND SUBSIDIARIES HARMLESS FROM AND AGAINST ALL DEMANDS, CLAIMS, SUITS, CAUSES OF ACTION, COSTS, EXPENSES, AND DAMAGES THAT TITAN MAY AT ANY TIME SUFFER OR SUSTAIN OR BECOME LIABLE FOR UNDER ANY LEGAL THEORY, INCLUDING WITHOUT LIMITATION, CONTRACT, WARRANTY, DECEPTIVE TRADE PRACTICE, NEGLIGENCE, PRODUCT LIABILITY AND STRICT LIABILITY IN TORT, BY REASON OF ANY ACCIDENTS, DAMAGES OR INJURIES, EITHER TO PERSONS OR PROPERTY OR BOTH, OF BUYER, OF ANY THIRD PARTY(S), OR OF TITAN OR ANY PERSONS OR FIRMS AFFILIATED WITH TITAN, THAT ARISE OUT OF OR RELATE TO THE USE OR MISUSE OF ANY ITEM SOLD HEREUNDER, INCLUDING, BUT NOT LIMITED TO, ANY USE OR MISUSE OF THE ITEM BY BUYER’S OFFICERS, AGENTS, EMPLOYEES, SUBCONTRACTORS, AFFILIATES, SUBSIDIARIES, OR ANY OTHER PERSON OR ENTITY TO WHOM THE ITEM HAS SUBSEQUENTLY BEEN SOLD OR TRANSFERRED. BUYER FURTHER AGREES THAT TITAN, ITS OFFICERS, EMPLOYEES, AGENTS, AFFILIATES AND SUBSIDIARIES, SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO BUYER BY WAY OF ANY INDEMNITY THEORY, WHETHER BASED ON STATUTE, INCLUDING BUT NOT LIMITED TO, CHAPTER 82 OF THE TEXAS CIVIL PRACTICES & REMEDIES CODE, CONTRACT OR THE COMMON LAW. (B) IN ADDITION TO THE INDEMNITY GRANTED BY BUYER TO TITAN AND BUYER’S WAIVER OF INDEMNITY FROM TITAN IN THE ABOVE SUBPARAGRAPH (A), BUYER FURTHER AGREES TO PROTECT, DEFEND, INDEMNIFY AND HOLD TITAN, ITS EMPLOYEES, OFFICERS, AGENTS, AFFILIATES AND SUBSIDIARIES, HARMLESS FROM AND AGAINST ALL DEMANDS, CLAIMS, SUITS, CAUSES OF ACTION, COSTS, EXPENSES, AND DAMAGES THAT TITAN MAY AT ANY TIME SUFFER OR SUSTAIN OR BECOME LIABLE FOR UNDER ANY LEGAL THEORY, INCLUDING WITHOUT LIMITATION, CONTRACT, WARRANTY, DECEPTIVE TRADE PRACTICE, NEGLIGENCE, PRODUCT LIABILITY AND STRICT LIABILITY IN TORT, BY REASON OF ANY ACCIDENTS, DAMAGES, OR INJURIES, EITHER TO PERSONS OR PROPERTY OR BOTH, OF BUYER, OF ANY THIRD PARTY(S), OR OF TITAN OR ANY PERSONS OR FIRMS AFFILIATED WITH TITAN, THAT ARISE OUT OF OR RELATE TO THE USE OR MISUSE OF ANY ITEM SOLD HEREUNDER THAT IS CAUSED BY OR RESULTS FROM THE SOLE OR CONCURRENT NEGLIGENCE OF TITAN, ITS OFFICERS, AGENTS, EMPLOYEES, AFFILIATES OR SUBSIDIARIES, IN THE DESIGN, MANUFACTURE, MARKETING, SALE OR DISTRIBUTION OF AN ITEM SOLD HEREUNDER. IT IS AGREED THAT BUYER’S INDEMNITY OBLIGATION UNDER THIS SUBPARAGRAPH (B) SHALL BE LIMITED TO THE SUM OF $500,000 AND SHALL BE SUPPORTED BY LIABILITY INSURANCE COVERAGE PROVIDED BY BUYER THAT IS SUFFICIENTLY ENDORSED TO WAIVE ANY AND ALL CLAIMS BY THE UNDERWRITERS OR INSURERS AGAINST TITAN. 4. Delivery Dates and Excusable Delays. All shipment and/or delivery dates are subject to Titan’s availability schedule. Titan will make every reasonable effort to meet any delivery date(s) quoted: however, Titan will not be liable for its failure to meet any quoted delivery date(s) or for any delay in performance due to any unforeseen circumstances or any causes beyond Titan’s control including, without prejudice to the foregoing generality, strike, lockout, riot, war, fire, acts of God, accident, failure or breakdown of parts necessary for completions, subcontractor, supplier, Buyer caused delays, inability to obtain labor, materials or manufacturing facilities, or compliance with any law, regulation or order, whether valid or invalid, of any governmental body or instrumentality thereof. Performance shall be deemed suspended during and extended for such time as any such circumstances or causes delay its execution. Whenever such circumstances or causes have been remedied, Titan will make and Buyer shall accept performance hereunder. No penalty clause of any kind shall be effective. As used herein, performance shall include, without limitation, fabrication, assembly, shipment, delivery and warranty repair or replacement, as applicable. 5. Packing. All items shall be packed, if appropriate, for shipping and storage in accordance with standard commercial practices. 6. Shipment.

Page 5: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 2

(a) All prices are net FOB Pampa, Texas. Buyer will pay all rigging, draying and transportation charges. (b) Normally Titan will ship in accordance with Buyer’s shipping instructions. In the absence of shipping instructions or unsuitable Buyer’s shipping instructions, Titan reserves the right to ship by an appropriate method. 7. Passage of Title. Title to items sold and risk of loss and damage shall pass to Buyer upon delivery by Titan to common carrier for shipment to Buyer, or to buyer directly, as the case may be. 8. Changes, Cancellations and Returns. (a) Titan reserves the right to change design(s), materials and specifications, and to discontinue item(s) without any notice or liability to Buyer. (b) If Buyer issues a change order or cancels an order, Buyer shall be liable to pay to Titan the whole cost and loss incurred by Titan resulting from such change or cancellation, as such is determined by Titan, which shall include all costs, direct and indirect, plus a pro rata proportion of normal profit. (c) No credit shall be given for any item returned unless returned with the prior approval of an authorized representative of Titan authorizing the return by issuing the Buyer a Return Goods Number. Only sales managers, major department managers, or officers of Titan are authorized to approve return of items. Risk of loss or damage in respect of any item returned with Titan’s authorization will remain with Buyer until redelivered to Titan. A charge of not less than fifteen percent (15%) or such larger amount as Titan may consider reasonable in the circumstances, with a minimum of $10.00 per item, will be charged by Titan on all items returned to pay for cost of inspection, repacking, handling, credit arrangements, etc. Titan shall not be responsible for holding or accounting for any items returned without prior authorization by Titan unaccompanied by the required Return Goods Number. If freight and other transportation costs are not prepaid on any returned item, the cost thereof will be deducted from the credit issued. No credit will be given on any non-standard item manufactured at the request of to the individual specifications of Buyer. 9. Other Manufacturer’s Equipment. If any items sold to Buyer by Titan contain any parts or materials obtained by Titan from any other party, these parts or materials are sold to Buyer AS IS. AS TO ANY SUCH PARTS OR MATERIALS, TITAN EXPRESSLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. BUYER’S REMEDY FOR ANY FAILURE OR DEFECT IN SUCH PARTS OR MATERIALS IS LIMITED TO REPAIR OR REPLACEMENT AS PROVIDED IN PARAGRAPH 12 BELOW. FURTHER, WITH RESPECT TO SUCH PARTS OR MATERIALS, TITAN DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. 10. Use and Acceptance of Item. Buyer warrants, by purchase of an item, that Buyer is familiar with the item and its proper use. Before using any item, Buyer shall give the item reasonable and prudent examination and/or tests to determine the suitability of the item for Buyer’s intended use. Buyer shall be deemed to have accepted any item by the Buyer’s use of the item, or in any event, no later than thirty (30) days after the first to occur of the date of shipment or delivery unless, before that time, Titan received written notice of any defect or nonconformity from Buyer. 11. Assistance to Customer At Buyer’s request, Titan may make Titan employees available to Buyer to train Buyer to operate items supplied by Titan or to perform other actions as agreed between Buyer and Titan. If Titan does make Titan employees available to Buyer, it is only on the conditions that the employees shall be under the direction and control of Buyer, Buyer shall supply all necessary equipment and supplies for the proper performance of the services performed by the employees, and Titan shall have no liability whatever to Buyer for the employees during the time that the employees are under Buyer’s direction and control. In addition, Buyer agrees that it will be responsible to Titan for any acts or occurrences or omissions of the employees, and agrees to the terms and conditions of paragraph 13 below with respect to the acts of such employees. 12. Repair of Items. Repairs to any item supplied by Titan and repaired at Buyer’s request outside the normal working hours of 8:00 am to 5:00 pm, (Monday through Friday) shall be charged by Titan at double the labor rate otherwise chargeable. 13. Limited Warranty and Remedy. (a) Titan is not liable for incidental, consequential, or special damages. UNDER NO CIRCUMSTANCES WILL TITAN BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES WITH RESPECT TO ANY GOODS OR SERVICES PROVIDED BY TITAN TO BUYER OR ANY THIRD PARTIES. (b) Buyer’s remedies are limited to repair and replacement. Buyer’s remedies for any and all breaches of any nature, including without limitation breaches of contract and warranty, are limited to the remedies of repair and replacement as specifically stated in this agreement. The remedies provided herein are the exclusive remedies of Buyer for failure of Titan to meet its warranty obligations, whether claims of Buyer are based on contract, in tort or otherwise, and upon expiration of the applicable warranty period, all obligations of Titan for breach of warranty will terminate. (c) Disclaimer of warranties not expressly stated. THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES WHETHER STATUTORY, EXPRESS OR IMPLIED. TITAN EXPRESSLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE. (d) Limited warranty. Titan warrants each item sold by it to Buyer (excluding any part or parts which are components to the item and are subject to Paragraph 8 above concerning parts supplied by others) to be free from defects in materials and workmanship if, and only if, all of the following conditions are met:

(1) The item claimed to be defective has been exposed only to normal storage, use, and service, has been reasonably maintained, has not been subjected to misuse, negligent use, or accident which caused the item to suffer a defect, and has not been repaired or altered except by an authorized representative of Titan;

(2) The item claimed to be defective has been returned at Buyer’s expense to Titan’s plant at Pampa, Texas (or to such other location as Titan may designate), within ten (10) days after Buyer first discovers the alleged defect;

Page 6: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 3

(3) The alleged defect in the item is actually caused by a defect in materials or workmanship originally supplied by Titan as opposed to materials or workmanship originally supplied by others; and

(4) The item is not one that is expendable in normal use and which has been expended in normal use.

(5) This warranty shall be in effect until 6 months after sale to purchaser, except: a) Subsurface electronic equipment is warranted only until 90 days after date of sale to purchaser, b) Scintillation detectors are warranted only to be in working order upon delivery to purchaser, and c) No subsurface electronic equipment is warranted against damage occurring when used in a down-hole drilling environment such as MWD or LWD operations.

(6) No subsurface electronic equipment will be warranted that has been modified or repaired by someone other than Titan’s approved representative. Equipment that has had its serial number or temperature indicator altered, defaced or removed will not be warranted.

(e) Limited remedies available under warranty. Titan’s liability under the limited warranty described above shall be limited to the repair or replacement of the items sold hereunder. Titan will repair or replace the item at no cost to Buyer, but the decision as to whether to repair or replace will be solely that of Titan’s. In addition, Buyer shall pay or reimburse Titan for the cost for wear and tear to each item arising from normal use and service, or at Titan’s option, Buyer shall refund an equitable proportion of the purchase price. Repairs or replacement items are only warranted for the remaining un-expired portion of the warranty period. (f) Notice of claims required. All claims under the warranty set out in this agreement must be made promptly after the alleged defect occurs and must be received by Titan within the warranty period. The claim must include the item’s description, part number, serial number (if any), date of shipment or delivery and a full description of the circumstances giving rise to the claim. Any item returned under claim of defect shall be sent prepaid by appropriate transportation. Buyer is responsible for all damage or loss resulting from improper packing or handling, and for any loss or damage occurring during the transmission of the item to Titan. If any item is returned and is found not to be defective, Titan will notify Buyer and, at Buyer’s option, will return the item to Buyer at Buyer’s expense. Further, in this event, Buyer will reimburse Titan for all costs incurred in testing and examining the item. 14. Miscellaneous. (a) All of these General Terms and Conditions including Buyer’s agreements to hold Titan harmless and indemnify Titan shall also apply in favor of all employees, agents, affiliates, and subsidiaries of Titan. (b) Order confirmation by Titan of any item to be supplied by Titan shall constitute Titan’s offer to sell the item in accordance with the terms, provisions and conditions of this Agreement. Buyer’s acceptance of Titan’s offer shall be limited to the terms, provisions and conditions of this Agreement. Any proposed acceptance by Buyer under terms, provisions or conditions that vary from, conflict with, or modify the terms, provisions and conditions of this Agreement shall not be effective. Neither Titan’s commencement of performance under this Agreement nor delivery of any item shall be construed as or deemed to be acceptance by Titan of any term, provision or condition that varies from, conflicts with, or modifies the terms, provisions and conditions contained in this Agreement. (c) This Agreement constitutes the entire understanding and agreement of Titan and Buyer with respect to the sale of the item or items described in this Agreement, and contains all of the covenants and agreements of Titan and Buyer with respect thereto. Acceptance of the item by Buyer will evidence Buyer’s acknowledgement that no representations, inducements, promises or agreements, oral or written, have been made by Titan or anyone acting on behalf of Titan, which are not contained herein, and any prior agreements, promises, negotiations, or representations not expressly set forth in this Agreement are of no force or effect. This Agreement may not be altered, changed or amended except by an instrument in writing signed by Titan and Buyer. (d) Failure by Titan to enforce any or all of these General Terms and Conditions in any case or cases shall not constitute a waiver of or preclude subsequent enforcement of any or all of such General Terms and Conditions. (e) Any attempted or purported assignment or transfer of any of the rights, duties or obligations herein contained shall render such attempted or purported assignment or transfer null and void, provided that Titan may perform and fulfill all or any of its obligations hereunder by or through any subsidiary and affiliate. If any provision of these terms and conditions is capable of more than one construction, the provision shall be interpreted in the manner which will render it valid. If any provision is determined to be void, the determination shall not affect any other provision and all other provisions not construed to be void shall remain in full force and effect. 15. Arbitration. ANY CONTROVERSY OR CLAIM ARISING OUT OF OR RELATING TO THIS AGREEMENT OR WITH REGARD TO ITS INTERPRETATION OR BREACH, SHALL BE SETTLED BY BINDING ARBITRATION IN ACCORDANCE WITH THE COMMERCIAL ARBITRATION RULES OF THE AMERICAN ARBITRATION ASSOCIATION. Unless otherwise required by applicable law, the parties hereto agree to arbitrate their differences in Amarillo, Texas. The parties further agree that all claims of any type by either party, including defenses and counterclaims, shall be included in the arbitration. Either party may send written notice to (a) the other party, and (b) any Regional Office of the American Arbitration Association invoking the binding arbitration provisions of this paragraph. The parties further consent to the jurisdiction of one of the state district courts sitting in Gray County, Texas, or the United States District Court for the Northern District of Texas, Amarillo Division, to enforce the provisions of this paragraph and/or to confirm any award rendered by the arbitrator. 16. Limited Statute of Limitations. AS PERMITTED BY Tex. Bus. & Com. Code Ann. §2.725, THE STATUTE OF LIMITATIONS FOR ANY BREACHES OF CONTRACT AND WARRANTY IS AGREED TO BE ONE YEAR FROM THE DATE THE CAUSE OF ACTION ACCRUES. 17. Choice of Law. ANY AGREEMENT OR TRANSACTION TO WHICH THESE GENERAL TERMS AND CONDITIONS APPLY SHALL BE DEEMED TO HAVE BEEN MADE IN THE STATE OF TEXAS. ANY CONTROVERSY OR CLAIM ARISING OUT OF OR RELATING TO THIS AGREEMENT OR WITH REGARD TO ITS INTERPRETATION OR BREACH SHALL BE GOVERNED BY AND CONSTRUED, INTERPRETED, AND ENFORCED IN ACCORDANCE WITH THE LAWS OF THE STATE OF TEXAS, INCLUDING, BUT NOT LIMITED, TO TEXAS SUBSTANTIVE AND PROCEDURAL LAW AND THE TEXAS VERSION OF THE UNIFORM COMMERCIAL CODE. NO DOCTRINE OF CHOICE OF LAW SHALL BE USED TO APPLY THE LAWS OF ANY OTHER STATE, NATION, OR JURISDICTION. 18. Use Agreement. Use of the items supplied or sold by Titan to Buyer shall constitute agreement of Buyer to these General Terms and Conditions.

Page 7: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 4

GENERAL COMMENTS ON GAMMA RAY LOGGING

The gamma ray log measures the natural gamma radiation produced by the disintegration, or decay, of radioactive nuclei in the formation. Since these nuclei tend to be more abundant in certain types of formations, the gamma ray log is basically a lithology log. The gamma ray log is used primarily as a shale log in the petroleum industry, since shale are generally the most radioactive sediments encountered in these wells. This log is used, in the mining and mineral industry, to locate and evaluate deposits of radioactive minerals such as potash or uranium ore. The gamma ray log is one of the most, if not the most, commonly used well logs. Part of this wide usage is due to the versatility of the log, which can be used in both cased and open holes with any type of borehole fluid. The utility of this log is also enhanced by the fact that it can be combined with many other logging services, and thus can be run with little additional cost either in money or rig time. Gamma ray logs are usually calibrated in API units. An API Gamma ray unit is defined as 1/200 of the difference in log deflection between zones of low and high radiation in the gamma ray calibration pit of the University of Houston as pictured on the next page. This pit shows three zones of artificially manufactured homogeneous radioactivity that correspond to the range of natural radioactivity. The center zone contains a radioactive concrete whose radiation is equal to approximately twice that of an average shale in the Mid-Continent region. The level of radioactivity was achieved in the center zone by incorporating in it 13 ppm uranium, 24 ppm thorium, and 40,000 ppm potassium.

Page 8: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 5

BRIEF DESCRIPTION OF TOOL This rugged Gamma Ray CCL tool is used with wireline perforating guns when very accurate depth control is required. The Gamma/CCL tool is physically attached to the top of a perforating gun after taking the measurement of distance from the CCL to the Gamma Ray measure point and the distance to the top shot in the gun. The assembly is then run into the well. After proper depth has been verified, the Gamma/Gun assembly is positioned opposite the zone to be perforated, and the gun may be fired with the Gamma Ray tool still on the line. Safety is achieved by normally powering the tool on a positive D.C. current and then switching to a negative D.C. current to fire the gun. A special safety firing circuit prevents the gun from being fired with the Positive polarity current. Different models of the tool may feature either a Scintillation detector or a Geiger Mueller detector with a special shock mounting designed to withstand the blast and shock of the perforator. The temperature rating of the tool can be up to 500° F (260° C) for the Scintillation Gamma Ray and up to 400°F (204° C) for the Geiger Gamma Ray

Page 9: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 6

API CALIBRATION PIT

Page 10: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 7

EXPLOSIVES FIELD SAFETY PROCEDURES A. GENERAL

1. Suspend perforating operations and isolate loaded guns when confronted with electrical storms, dust storms, or thunder storms at the job site.

2. Continuity checks are to be performed only with a blasting galvanometer or an approved digital blaster multimeter.

B. ARRIVAL ON LOCATION

1. Hold spot safety meeting 2. Check for hazards and correct. 3. No smoking except in permissible areas. 4. Check rig for stray voltage. Eliminate if present. 5. Install safety grounding cables. Do not proceed if voltage is in excess of .25 volts.

C. BEFORE ARMING GUN

1. Put patch cord in “safe” position. 2. Shut off ac generator. Do not restart until gun is 200 ft. (60 meters) into well. 3. Turn off all power switches and leave “off” until gun is 200 ft. (60 meters) into well. 4. Turn off all radio transmitters. 5. Put “blasting caps in use, no radio transmissions” signs out along all access roads. 6. Clear line of fire of all personnel, and clear area of all unnecessary personnel.

D. PERFORATING GAMMA RAY TOOLS Users of Titan perforating gamma ray tools must be aware of the following conditions:

1. Perforating gamma ray tools use an electrical energy storing device. When attached to a wire line cable the energy storage capability is increased. Dual diode and series resistance (120 ohm) protection is provided. However, any electrical device is subject to failure. Tool power is not to be applied until the instrument is at least 200 ft. (60 meters) into the hole. Turn off power and place system in the safe position when the gun reaches 200 ft. (60 meters) from the surface as it is being withdrawn from the well.

2. Use resistor type caps. 3. The tool is designed to run on positive 120 vdc. When a negative current is applied, with respect to the

cable armor, detonation of the blasting cap will occur. Maintenance requirements for shooting and perforating tools are generally higher and must have trained personnel to ensure the safe use of these instruments.

Page 11: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 8

TOOL SPECIFICATIONS Tool Description ................... 2 3/4” HIGH-TEMP SS PERF SCINT GR WITH ACTIVE/PASSIVE CCL & SHOCK Dimensions and Ratings Length........................................................................................................................................ 103.19” (262.10 cm) Weight.............................................................................................................................................102 lbs. (46.2 kg) Maximum Diameter.......................................................................................................................... 2 3/4” (6.99 cm) Pressure Rating ...................................................................................................................... 20,000 psi (138 mpa) Model # and Temperature Rating 8100-275BESF100-04-0C-A ................................................................................................................ 500° f (260° c) Operating Voltage.................................................................................................................................120 vdc pos. Operating Current.................................................................................................................................60 milliamps CCL to GR Spacing....................................................................................................................... 24.12” (61.26 cm) Logging Speed / Time Constant.................................................. 20 ft (6.096 m) to 30 ft (9.144 m) / min – 3 sec.

Page 12: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 9

TOOL SPACING

58.37 in [148.27 cm]

41.82 in [106.22 cm]

24.12 in [61.26 cm]

64.63 in [164.17 cm]

22.81 in [57.95 cm]

103.19 in [262.10 cm]

Page 13: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 10

CO

MPLETE TO

OL A

SSEMB

LY

Page 14: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 11

GA

MM

A R

AY &

CC

L TOO

L ASSEM

BLY

Page 15: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 12

TOP SU

B A

SSEMB

LY

Page 16: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 13

CO

IL & M

AG

NET A

SSEMB

LY

Page 17: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 14

CC

L PC B

OA

RD

ASSEM

BLY

Page 18: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 15

CC

L SCH

EMA

TIC

Page 19: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 16

TAN

DEM

AD

APTER

ASSEM

BLY

Page 20: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 17

UPPER

CO

NTA

CT H

EAD

ER A

SSEMB

LY

Page 21: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 18

INTER

NA

L GA

MM

A R

AY A

SSEMB

LY

D14

D13

D12

D11

D11D12D13D14

Page 22: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 19

CH

ASSIS A

SSEMB

LY

Page 23: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 20

TOP SC

INTILLA

TION

GA

MM

A R

AY PC

BO

AR

D A

SSEMB

LY

Page 24: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 21

BO

TTOM

SCIN

TILLATIO

N G

AM

MA

RA

Y PC B

OA

RD

ASSEM

BLY

Page 25: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 22

SCIN

TILLATIO

N G

AM

MA

RA

Y PC B

OA

RD

SCH

EMA

TIC

Page 26: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 23

SCH

EMA

TIC (PA

GE 2)

Page 27: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 24

BO

TTOM

SUB

ASSEM

BLY

Page 28: Ggr Manual

Manual: 02K

M27E

H-A

R

evision Date: 10/15/2004

Page 25

SHO

CK

AB

SOR

BER

ASSEM

BLY

Page 29: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 26

BILL OF MATERIAL LEVEL PART NUMBER DESCRIPTION QTY

1 3100-312-S000R 3 1/8" S.S. SHOCK ABSORBER ASSY 12 0111-013-V95 1/16 X 7/16 X 9/16 O-RING VITON-95 42 0111-115-V95 3/32 X 11/16 X 7/8 O-RING VITON-95 22 0111-222-090 1/8 X 1 1/2 X 1 3/4 O-RING-90 12 0111-222-V95 1/8 X 1 1/2 X 1 3/4 O-RING VITON-95 42 0111-333-V95 3/16 X 2 1/2 X 2 7/8 O-RG VITON-95 22 0256-000-008 CONTACT PLUNGER, 303/304 STAINLESS 12 0256-000-037 STEM PROTECTOR, "GO" QUICK-CHANGE 12 0257-000-017 PROTECTOR; QUICK-CHANGE BOX 12 0257-000-036 TERMINAL SCREW (STAINLESS) 12 0257-0SS-005 SET SCREW; 5/16-24 X 3/8 LONG - SS 22 0263-000-143 GROUND SPRING 12 3100-000-150 SUPPORT RING 22 3100-168-110 INSTALLATION TOOL 12 3100-168-116 RETAINER DISC; FEED THRU ASSY 12 3100-168-121 CONTACT ADAPTER 22 3100-168-122 CONTACT INSULATOR 22 3100-168-123 CONTACT SOCKET 12 3100-168-124 CONTACT RECEPTACLE 12 3100-312-014 ALIGNMENT SCREW; 3 1/8 SHOCK 12 3100-312-015V UPPER SHOCK CUSHION - VITON 42 3100-312-016A RUBBER ABSORBER SLEEVE - AFLAS 42 3100-312-025 BACK-UP RING; UPPER SHOCK CUSHION 32 3100-312-040 CABLE & BOOT ASSEMBLY; SHOCK ABS 13 3100-312-119 BOOT RETAINER 23 E2100-16-B-01381-34 K-25-SFT BOOT W/CONTACT; CRIMP 23 E6000-IC20-SS302-2-RED WIRE; .032 20AWG 302 SS PTFE RED 482 3100-312-105 INNER TUBE; 3 1/8 SHOCK ABSORBER 12 3100-312-109 CONTACT ADAPTER BODY 12 3100-312-115 FEED THRU ASSY. TOOL 12 3100-312-S011 TOP ADAPTER BODY;3 1/8 SHOCK ABS SS 12 3100-312-S012 MANDREL BODY; 3 1/8" SHOCK ABS SS 12 3100-312-S013 HOUSING; 3 1/8 SHOCK ABSORBER SS 12 3100-312-S104 BOTTOM ADAPTER SUB; 3 1/8 SHOCK SS 12 3100-312-S108 UPPER HOUSING SUB 3 1/8" SS 12 3903-000-009 CONTACT SPRING 12 3903-000-011 PLUNGER INSULATOR 12 3903-000-012 SNAP RING 12 E2100-16-B-01848-00 K-25-BMAL GLASS/POLYETHER FEED THRU 21 8100-275BESF100-04-01-A GR/CCL 2-3/4 HT PERF. SCINTILLATION 12 0111-222-090 1/8 X 1 1/2 X 1 3/4 O-RING-90 12 0257-000-017 PROTECTOR; QUICK-CHANGE BOX 12 3924-120-FBE PROTECTOR; FOR BOX END (PLASTIC) 12 8100-275-030 SHOCK ABSORBER ASSEMBLY 22 8100-275-601-2 HOUSING; 2 3/4 HI-TEMP GAMMA PERF 12 8100-275-653 2 3/4" HT UPPER CONTACT HEADER ASSY 13 0111-327-V75 3/16 X 1 3/4 X 2 1/8 O-RG VITON-75 13 0255-000-004 CONTACT SOCKET (10-32 THD.) 303 SS 13 3903-000-007 INSUL WASHER; 5/8"OD 30% GLASS PEEK 23 8100-000-033 CONTACT PIN; BOOT & CONTACT TYPE 13 8100-275-056 SPACER SPRING 13 8100-275-654 UPPER CONTACT HEADER BODY 13 8100-275-655 SPACER SPRING CAP 1

Page 30: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 27

3 E2100-128229 BOOT AND CONTACT 12 8100-275-684 SHOCK SLEEVE 42 8100-275-S10 2 3/4" S.S TANDEM ADAPTER ASSEMBLY 13 0111-010-V95 1/16 X 1/4 X 3/8 O-RING VITON-95 13 0111-014-V95 1/16 X 1/2 X 5/8 O-RING VITON-95 13 0111-227-V95 1/8 X 2 1/8 X 2 3/8 O-RING VITON-95 43 3903-000-007 INSUL WASHER; 5/8"OD 30% GLASS PEEK 13 3903-000-008 CONTACT NUT 303/304 SS 13 3903-000-009 CONTACT SPRING 13 3903-000-010 CONTACT PLUNGER 303/304 SS 13 3903-000-011 PLUNGER INSULATOR 13 3903-000-012 SNAP RING 13 3903-000-107 BANANA PLUG; SPINNING TYPE, 10-32 13 8100-000-025 SEAL CONTACT RECEPTACLE INSULATOR 13 8100-000-027 SEAL CONTACT RECEPTACLE (STAINLESS) 13 8100-275-S11 TANDEM ADAPTER BODY, SS 13 8100-312-013 CONTACT ROD, INSULATED, 2" LONG 12 8100-275-S120 2 3/4" S.S BOTTOM ADAPTER ASSEMBLY 13 0111-012-V95 1/16 X 3/8 X 1/2 O-RING VITON-95 13 0111-211-V95 1/8 X 13/16 X 1 1/16 O-RG VITON-95 13 0111-227-V95 1/8 X 2 1/8 X 2 3/8 O-RING VITON-95 23 3903-000-007 INSUL WASHER; 5/8"OD 30% GLASS PEEK 13 8100-000-014 SEAL CONTACT SOCKET, STAINLESS 13 8100-000-015 SEAL CONTACT SOCKET INSULATOR 13 8100-000-033 CONTACT PIN; BOOT & CONTACT TYPE 13 8100-275-S121 SS BOTTOM SUB BODY. GO Q-CHG. 13 E2100-128229 BOOT AND CONTACT 12 8100-275B1SF100-04 INTERNAL GR ASSY 2 3/4" 500°F PERF. 13 0111-221-V75 1/8 X 1 7/16 X 1 11/16 O-R VITON-75 23 0111-323-V75 3/16 X 1 5/16 X 1 11/16 O-RG VIT-75 23 0111-323-V75 3/16 X 1 5/16 X 1 11/16 O-RG VIT-75 23 0111-327-V75 3/16 X 1 3/4 X 2 1/8 O-RG VITON-75 23 0263-000-143 GROUND SPRING 13 8100-168-078 COMPRESSION SPRING 13 8100-168-675-4 PLUG; HEAT INSULATOR 13 8100-275-163 DETECTOR HOUSING; SCINT. DETECTOR 13 8100-275-662 UPPER DETECTOR HEADER 13 8100-275-663 LOWER DETECTOR HEADER 13 8100-275-665 COMPONENT CHASSIS 13 8100-275-675-4 HEAT INSULATOR ASSY. 13 8100-275-680 VACUUM FLASK; HI-TEMP PERF. SCINT. 13 8100-275-683 SHOCK CUSHION; 1.70 OD X 1/4 THICK 43 8100-275B1SF CHASSIS ASSEMBLY; HT PERF. SCINT. 14 0111-323-V75 3/16 X 1 5/16 X 1 11/16 O-RG VIT-75 24 8100-275-650 PC CHASSIS; HI-TEMP PERF. SCINT. GR 14 8100-312B7S-1 PC BOARD ASSY; 3 1/8" HT SCINT 15 8100-PCB6-312-1 PC BOARD; 3 1/8 HT SCINTILLATION 15 E1100-5002 LINE DRIVER 15 E1100-LM6165J/883 OP AMP 15 E1500-135D107X0025F2 CAPACITOR, 100 UF @ 25V, 200°C 15 E1500-135D336X0075F2 CAPACITOR, 33 UF @ 75V, 200°C 15 E1500-135D365X0125C2 CAPACITOR, 3.6 UF @ 125V, 200°C 25 E1500-30HV11N101K CAPACITOR, HIGH VOLTAGE, 200°C 15 E1500-CCR05CG101JR CAPACITOR, 100PF@100V NPO MIL SPEC 15 E1500-CCR05CG102JR CAPACITOR, 1000PF@100V NPO MIL SPEC 1

Page 31: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 28

5 E1500-CK05BX100K CAPACITOR, 10PF 200V 15 E1500-CK05BX104K CAPACITOR, .1UF 50V 25 E1500-CK06BX105K CAPACITOR, 1UF 50V 15 E3130-MC14520BCL INTEGRATED CIRCUIT 15 E4700-CMF55C1004 RESISTOR, 1M 35 E4700-RN55C1000 RESISTOR, 100 OHMS 25 E4700-RN55C1002 RESISTOR, 10K 25 E4700-RN55C1003 RESISTOR, 100K 25 E4700-RN55C10R0 RESISTOR, 10 OHM 15 E4700-RN55C2212 RESISTOR 15 E4700-RN55C2213 RESISTOR 15 E4700-RN55C4752 RESISTOR 35 E4800-1N6154A TRANSIT PROTECTOR, 25V, CERAMIC 15 E4801-2N2222 TRANSISTOR 14 8100-312B7S-2 PC BOARD ASSY; 3 1/8" HT SCINT 15 8100-PCB6-312-2 PC BOARD; 3 1/8 HT SCINTILLATION 15 E1500-135D227X9060T2 CAPACITOR, 220 UF @ 60V, 200°C 15 E1500-30HV13B103K CAPACITOR, HIGH VOLTAGE, 200°C 25 E1500-CCR05CG101JR CAPACITOR, 100PF@100V NPO MIL SPEC 25 E1500-CK05BX103K CAPACITOR, .01UF 100V 15 E1500-CK06BX105K CAPACITOR, 1UF 50V 35 E1800-IMS-5-10000 COIL/CHOKE, 10000 MICRO HENRY 15 E3100-177-5-30 INSULATING WAFER, T05 TRANSISTOR 15 E3130-SI9110DJ IC, SWITCHMODE CONTROLLER 15 E4700-CMF55C1504 RESISTOR, 1.5M 15 E4700-CMF55C3323 RESISTOR, 332K 15 E4700-RLR05C4R99F RESISTOR, 4.99 OHMS 15 E4700-RN55C3923 RESISTOR 15 E4700-RN55C4991 RESISTOR, 4.99K 15 E4700-RNX-1/2-200MDH RESISTOR, 200M, 2KV 15 E4800-HTD3 DIODE, HV 15 E4802-IRFF330 TRANSISTOR 15 E5600-22HV TRANSFORMER, HV, SURFACE MOUNT 14 E2100-1125-21-0519 TERMINAL, TEFLON 54 E4700-RS-5-50K RESISTOR, 5W, 50K 14 E4800-1N5627 DIODE (CCL COMPONENT)GLASS/CERAMIC 14 E4800-JANTX1N5622 DIODE 33 8100-312-046 SHOCK CUSHION; 1.44 X .50 X .12 43 8100-337-067 HOUSING; PM TUBE ASSY. 13 8100-337-098 HEAT SHIELD SHOCK SLEEVE W/HOLES 13 81PM-R3991-27 PM TUBE ASSEMBLY; 350°F 13 E2100-1125-21-0519 TERMINAL, TEFLON 103 E2920-1.00X4.0-7P SCINTILLATION CRYSTAL 1000G 13 E2920-BC-637-A 1 X .079 HIGH TEMPERATURE GEL PADS 13 E4700-RH-10-2K RESISTOR, 2K 10W 13 E4800-1N4960 ZENER, 12V 5W GLASS OR CERAMIC 23 E4800-CMPD400 DIODE, TEMP COMP, .008V/DEG C 23 E5300-AL03006-535K-145-G1 THERMISTER, NTC, 1M 12 8100-312-036 WAVE SPRING; GROUND 12 8130-275-001 HOUSING; 2 3/4 LOGGING CCL 12 8130-275-S10 TOP SUB ASSEMBLY; GO BOX 13 0111-012-V95 1/16 X 3/8 X 1/2 O-RING VITON-95 13 0111-211-V95 1/8 X 13/16 X 1 1/16 O-RG VITON-95 13 0111-227-V95 1/8 X 2 1/8 X 2 3/8 O-RING VITON-95 23 0255-000-004 CONTACT SOCKET (10-32 THD.) 303 SS 1

Page 32: Ggr Manual

Manual: 02KM27EH-A Revision Date: 10/15/2004 Page 29

3 3903-000-007 INSUL WASHER; 5/8"OD 30% GLASS PEEK 13 3903-000-033 CONTACT ROD; INSULATED, 2 1/2" LG 13 8100-000-014 SEAL CONTACT SOCKET, STAINLESS 13 8100-000-015 SEAL CONTACT SOCKET INSULATOR 13 8130-275-S11 TOP SUB BODY; 2 3/4" GO BOX 12 8730-2757-B30 LOGGING C & M ASSY; ACTIVE/PASSIVE 13 0255-000-004 CONTACT SOCKET (10-32 THD.) 303 SS 13 0265-000-035 MAGNET 23 3903-000-007 INSUL WASHER; 5/8"OD 30% GLASS PEEK 43 3903-000-107 BANANA PLUG; SPINNING TYPE, 10-32 13 8100-000-023 CONTACT ROD W/SOLDER POST 303/304SS 13 8100-000-059 SPACER; FOR TRANSFORMER 43 8100-312-036 WAVE SPRING; GROUND 13 8130-168-003 CONTACT ROD 13 8130-168-049A SHOCK CUSHION, 1.00 X .62 X .12 13 8130-168BEM PC BOARD ASSY; 500°F CCL ACT/PASS 14 8130-PCBE-168 PC BOARD; CCL ACTIVE/PASSIVE 500°F 14 E1500-123-17688 6.8UF @ 40V, SOLID ALUM, 200°C 14 E4500-ER412-12A RELAY, TELEDYNE TO5 14 E4700-CMF55C5004 RESISTOR, 5M 14 E4700-RN55C1002 RESISTOR, 10K 14 E4700-RN55C2212 RESISTOR 14 E4700-RS-2B-5K RESISTOR, 3W, 5K OHM 14 E4800-1N4744 ZENER, 15V 1W GLASS OR CERAMIC 14 E4800-1N4958 ZENER, 10V 5W GLASS OR CERAMIC 14 E4800-1N4960 ZENER, 12V 5W GLASS OR CERAMIC 14 E4800-1N5062 DIODE; GAMMA TOOL GLASS OR CERAMIC 13 8130-275-033 CHASSIS END FITTING, UPPER 13 8130-275-034 CHASSIS END FITTING, LOWER 13 8130-275-040 2 3/4" LOGGING CCL COIL ASSEMBLY 13 8130-275-048 LOWER SHOCK MOUNT 13 8130-275-049 SHOCK CUSHION; 2.05 X 1.00 X .25 13 8130-275-130 CHASSIS; 2 3/4 CCL 13 E4700-MP820-3K RESISTOR, 3K, 20W, TO-220 13 E4802-IRFMG50 MOS-FET, 1000V, TO-254AA 12 E4700-RH-10 649 OHM RESISTOR, 649 OHM, 10W 1