global united technology services co., ltd. - · pdf filereport no: gts201612000023m01 global...
TRANSCRIPT
Global United Technology Services Co., Ltd.
Report No.: GTS201612000023M01
Authorized Signature:
Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced,
except in full, without prior written permission of the company. The report would be invalid without specific
stamp of test institute and the signatures of compiler and approver.
Test Report
Applicant: Dragino Technology Co., Limited
Address of Applicant: Room 7009, Zi'An Commercial Building, Qian Jin 1 Road.
Xin'An 6th District, Bao'an District ; Shenzhen 518101,China
Manufacturer/Factory: Dragino Technology Co., Limited
Address of
Manufacturer/Factory:
Room 7009, Zi'An Commercial Building, Qian Jin 1 Road.
Xin'An 6th District, Bao'an District ; Shenzhen 518101,China
Equipment Under Test (EUT)
Product Name: Wireless IoT Module
Model No.: LoRa mini
Applicable standards: ARIB STD T-108 Ver. 1.0
MIC public notice 88:2004, Annex 22
Date of sample receipt: December 29, 2016
Date of Test: December 29, 2016-January 05, 2017
Date of report issued: January 05, 2017
Test Result : PASS *
* In the configuration tested, the EUT complied with the standards specified above.
Global United Technology Services Co., Ltd.
Report No.: GTS201612000023M01
2 Version
Version No. Date Description
00 January 05, 2017 Original
Prepared By: Date: January 05, 2017
Project Engineer
Check By: Date: January 05, 2017
Reviewer
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 32
3 Contents Page
1 COVER PAGE ................................................................................................................................................. 1
2 VERSION ........................................................................................................................................................ 2
3 CONTENTS .................................................................................................................................................... 3
4 TEST SUMMARY ........................................................................................................................................... 4
5 GENERAL INFORMATION ............................................................................................................................ 5
5.1 GENERAL DESCRIPTION OF EUT ............................................................................................................... 5 5.2 TEST MODE .............................................................................................................................................. 6 5.3 TEST CONDITION ....................................................................................................................................... 6 5.4 TEST FACILITY .......................................................................................................................................... 6 5.5 TEST LOCATION ........................................................................................................................................ 6 5.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................... 6 5.7 TEST INSTRUMENTS LIST ........................................................................................................................... 7 5.8 MEASUREMENT UNCERTAINTY ................................................................................................................... 7
6 TEST RESULTS AND MEASUREMENT DATA ............................................................................................ 8
6.1 FREQUENCY ERROR ................................................................................................................................. 8 6.2 ANTENNA POWER ..................................................................................................................................... 9 6.3 OCCUPY BANDWIDTH (99%) ................................................................................................................... 11 6.4 CHANNEL SEPARATION ........................................................................................................................... 13 6.5 ADJACENT CHANNEL LEAKAGE POWER ..................................................................................................... 14 6.6 SPURIOUS EMISSION INTENSITY ............................................................................................................... 16 6.7 TRANSMISSION TIME CONTROL EQUIPMENT .............................................................................................. 26 6.8 INTERFERENCE PREVENTION FUNCTION .................................................................................................... 28 6.9 CARRIER SENSE CAPABILITY .................................................................................................................. 29
7 TEST SETUP PHOTO .................................................................................................................................. 30
8 EUT CONSTRUCTIONAL DETAILS ........................................................................................................... 31
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 32
4 Test Summary
Test Item Result
RF shielding method Pass
Frequency Error Pass
Antenna Power Pass
99% Occupied bandwidth Pass
Channel Separation N/A
Adjacent channel leakage power Pass
Spurious Emissions Intensity Pass
Transmission time control equipment Pass
Interference suppression Pass
Carrier Sense Capability N/A
Pass: The EUT complies with the radio interference prevention capability.
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 32
5 General Information
5.1 General Description of EUT
Product Name: Wireless IoT Module
Model No.: LoRa mini
Operation Frequency: 922.4MHz
Channel numbers: 1
Modulation technology: FSK
Data Rate: 1Mbps (declare by manufacturer)
Rated power: 16mW
Antenna Specification: Integrity Antenna
Antenna Gain: 2.69dBi
Hardware Version: v1.3
Software Version: v1.0
AC Adapter Information: AC/DC ADAPTER
Model : TP06-120100U
Input : AC 100-240V, 50/60Hz, 0.5A Max
Output : DV 12V 1.0A
Channel List
Channel Frequency (MHz)
1 922.4MHz
Tested Channels:
Channel Frequency (MHz)
1 922.4MHz
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 32
5.2 Test mode
Software used to control the EUT for staying in continuous transmitting and receiving mode is programmed.
5.3 Test condition
Voltage fluctuation test Normal voltage High voltage
+10% of Normal voltage
Low voltage
-10% of Normal voltage
DC power 12.00 13.20 10.80
Temperature: 25 ˚C Humidity: 52%
During the input supply voltage to the EUT from the external power source is varied by +/-10%, EUT only
operated in normal, High and Low voltage to test all regulations.
5.4 Test Facility The test facility is recognized, certified, or accredited by the following organizations: ● FCC —Registration No.: 600491 Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in files. Registration 600491,June 22, 2016. ● Industry Canada (IC) —Registration No.: 9079A-2 The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 9079A-2, August 15,2016
5.5 Test Location All tests were performed at: Global United Technology Services Co., Ltd. Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China Tel: 0755-27798480
Fax: 0755-27798960
5.6 Other Information Requested by the Customer
None.
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 32
5.7 Test Instruments list
Item Test Equipment Manufacturer Model No. Inventory
No. Cal.Date
(mm-dd-yy)
Cal.Due date
(mm-dd-yy)
1 3m Semi- Anechoic
Chamber ZhongYu Electron 9.0(L)*6.0(W)* 6.0(H) GTS250 July 03 2015 July 02 2020
2 EMI Test Receiver Rohde & Schwarz ESU26 GTS203 June 29 2016 June 28 2017
3 Spectrum Analysis Agilent E4440A GTS205 June 29 2016 June 28 2017
4 Coaxial cable GTS N/A GTS210 June 29 2016 June 28 2017
5 Constant temperature
and humidity box Oregon Scientific BA-888 GTS248 June 29 2016 June 28 2017
6 D.C. Power Supply Instek PS-3030 GTS232 June 29 2016 June 28 2017
7 Signal Generator Rohde & Schwarz SML02 GTS235 June 29 2016 June 28 2017
8 Horn Antenna ETS-LINDGREN 3160-09 GTS218 June 29 2016 June 28 2017
9 RF Amplifier HP 8349B GTS206 June 29 2016 June 28 2017
10 Broadband
Preamplifier SCHWARZBECK BBV9718 GTS535 June 29 2016 June 28 2017
11 EMI Test Software AUDIX E3 N/A N/A N/A
12 Thermo meter N/A N/A GTS256 June 29 2016 June 28 2017
All of the instruments are calibrated by CEPREI Calibration and Testing Center.
5.8 Measurement uncertainty For the test methods, according to the present document, the measurement uncertainty figures shall be calculated in accordance with TR100028-1 [2] and shall correspond to an expansion factor (coverage factor) K=1.96 or K=2 (which provide confidence levels of respectively 95% and 95.5% in the case where the distributions characterizing the actual measurement uncertainties are normal.
Parameter Uncertainty RF frequency +/-6*10-7
Total RF power, conducted +/-0.8dB Spurious emissions, conducted +/-0.8dB DC and low frequency voltages +/-3%
Humidity +/-5% Temperature +/-1°C
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 32
6 Test results and Measurement Data
6.1 Frequency Error
Test condition: Without modulation, continuously transmitting.
Spectrum set: Test Frequency: test channel,
RBW=VBW=10KHz, Span=1MHz, Sweep time=Auto, Detector mode=Positive peak
Limit: 20ppm
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: Pass
Measurement Data
Test voltage Frequency
(MHz) Read (MHz)
Deviation (KHz)
Tolerance (ppm)
Limit (ppm)
Result
DC=10.80V 922.40 922.451 5.1 5.53
20 Pass DC=12.00V 922.40 922.451 5.1 5.53
DC=13.20V 922.40 922.451 5.1 5.53
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 32
6.2 Antenna Power
Test condition: Test diffusion code and modulate with standard coding test signal
Spectrum set: Measurement procedure
1. Search Frequency of Peak Power
Test Frequency: test channel,
RBW=VBW=1MHz, Span=5MHz, Sweep time=Auto, Detector mode =Positive peak
2. Measure of average burst power
Test Frequency: frequency of peak power
RBW=VBW=1MHz, Span=0Hz, Sweep time=Auto, Detector mode=Positive peak
3. Antenna power= average burst power
Rating power: 16mW
Limit: 20mW
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: Pass
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 32
Measurement Data
Test voltage Frequency
(MHz) Antenna Power
(mW) Rated output power (mW)
Tolerance (%) Limit
DC=10.80V 922.40 18.75 16.00 17.19
-80%~+20% DC=12.00V 922.40 18.79 16.00 17.44
DC=13.20V 922.40 18.79 16.00 17.44
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 32
6.3 Occupy Bandwidth (99%)
Test condition: Test diffusion code and modulate with standard coding test signal
Spectrum set: Test Frequency: test channel,
RBW=10KHz, VBW=30KHz, Span=1MHz, Sweep time=Auto, Detector
mode=Positive peak
Limit: 200KHz or less
Test setup:
Test Instruments: Refer to section 5.8 for details
Test mode: Transmitting mode
Test results: Pass
Measurement Data
Test voltage 99% occupy bandwidth
(KHz) Limit (KHz) Result
DC=10.80V 53.6910
<200 Pass DC=12.00V 53.6550
DC=13.20V 53.8439
Test plot as follows:
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 32
Test Voltage: DC=10.80V
Test Voltage: DC=12.00V
Test Voltage: DC=13.20V
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 32
6.4 Channel Separation
Test condition: Test diffusion code and modulate with standard coding test signal
Spectrum set: Test Frequency: test channel,
RBW=10KHz, VBW=30KHz, Span=1MHz, Sweep time=Auto, Detector
mode=Positive peak
Limit: 200KHz or less
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: N/A
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 32
6.5 Adjacent channel leakage power
Test condition: Test diffusion code and modulate with standard coding test signal
Spectrum set: Test Frequency: test channel,
RBW=100KHz, VBW=300 KHz, Sweep time=Auto, Detector
mode=Positive peak
Limit:
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: Pass
Measurement Data
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 15 of 32
Test plot as follows:
Test Voltage: DC=10.80V
Test Voltage: DC=12.00V
Test Voltage: DC=13.20V
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 16 of 32
6.6 Spurious emission intensity
Test condition: Test diffusion code and modulate with standard coding test signal
Measurement procedure: Step 1
All spurious are measured from 10MHz to 13GHz by peak mode.
Step 2
If the value measured by Step1 is 3dB or less to the limit, measure in average mode.
Limit:
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: Pass
Test plot as follows:
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 17 of 32
Test Voltage: DC=10.80V Frequency: 922.4MHz
10M-710M
710M-900M
900M-915M
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 18 of 32
915M-922.1M
922.7M-930M
930M-1G
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 19 of 32
1G-1.215G
1.215G-13G
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 20 of 32
Test Voltage: DC=12.00V Frequency: 922.4MHz
10M-710M
710M-900M
900M-915M
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 21 of 32
915M-922.1M
922.7M-930M
930M-1G
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 22 of 32
1G-1.215G
1.215G-13G
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 23 of 32
Test Voltage: DC=13.20V Frequency: 922.4MHz
10M-710M
710M-900M
900M-915M
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 24 of 32
915M-922.1M
922.7M-930M
930M-1G
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 25 of 32
1G-1.215G
1.215G-13G
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 26 of 32
6.7 Transmission time control equipment
Test condition: Test diffusion code and modulate with standard coding test signal
Spectrum set: Measurement procedure
RBW=VBW=1MHz, Span=0Hz, Sweep time=Auto, Detector mode=Positive peak
Limit: Using two unit radio channels: radio equipment shall stop its emission of radio wave less than 200ms after it starts to emit radio wave. The sum of emission time per arbitrary one hour shall be 360s or less. Meanwhile if the emission time is more than 3ms, it shall wait for 2ms for the consecutive emission.
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: Pass
Measurement data:
Ton time:
Test voltage Frequency
(MHz) Ton time(ms) Limit (ms) Result
DC=10.80V 922.40 283.3
200 Pass DC=12.00V 922.40 266.7
DC=13.20V 922.40 266.7
Sum emission time of arbitrary one hour
Test voltage Frequency
(MHz) Ton time(ms)
Transmitting separation(s)
Sum emission time of arbitrary
one hour(s) Limit (s) Result
DC=10.80V 922.40 283.3 5.300 192.4
360 Pass DC=12.00V 922.40 266.7 5.284 181.7
DC=13.20V 922.40 266.7 5.284 181.7
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 27 of 32
Test Voltage: DC=10.80V
Test Voltage: DC=12.00V
Test Voltage: DC=13.20V
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 28 of 32
6.8 Interference prevention function
Measurement procedure: (1) The radio equipment with automatic transmitting function of identification code
a) Transmit the assigned identification code from the radio equipment.
b) Confirm the identification code received by the demodulator.
(2) The radio equipment with automatic receiving function of identification code
a) Transmit the assigned identification code from the opposite equipment.
b) Confirm that the usual communication is available.
c) Transmit the identification code distinct from the assigned one from the opposite equipment.
d) Confirm that the radio equipment is stopped or an indication is displayed as the identification code is different.
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: Pass
Measurement data:
Identification function: Good
Radio equipment Dummy load Attenuator
Demodulator
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 29 of 32
6.9 Carrier Sense Capability
Limit: Stop transmission for interference signal level above 100mV/m (or level at 22.79+Gr-20*log(f)[dBm])
f: indicated frequency in MHz
Gr: indicated the antenna gain in dBi
Spectrum set: Attenuation Auto
RBW/VBW 1MHz/1MHz
Span 0Hz
Sweep time 10s
Detector Peak
Trigger mode Free Run
Measurement procedure: 1. SSG adjusted the frequency as same as the EUT transmitted signal and emitted the absence of modulation from SSG. Then turn off the RF signal of SSG.
2. EUT have transmitted the maximum modulation signal and fixed channelize.
3. Set the Spectrum per the above form.
4. SSG RF signal on, and adjust the signal level until the EUT stop transmission at the tested frequency. Record the signal level.
5. EUT shall be stop the transmission and SSG RF signal off. Then EUT will be continuously transmitted signal.
Test setup:
Test Instruments: Refer to section 5.8 for details
Test results: Pass
Measurement data:
N/A
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 30 of 32
7 Test Setup Photo
Remark: RF line impedance is 50 Ohm
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 31 of 32
8 EUT Constructional Details
Report No: GTS201612000023M01
Global United Technology Services Co., Ltd. No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 32 of 32
------End------